CAMPUS POWER ONE-LINE 2018-06-25.pdf

PDF 1 MB Posted

Attached to
J061--(S4) (660) Switchgear Preventative Maintenance Federal contract opportunity
Solicitation number
36C25923Q0060
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19

View the file

Other files for this federal contract opportunity

Other files attached to J061--(S4) (660) Switchgear Preventative Maintenance, newest first.
File Type Posted
VA Campus Map (with Medium Voltage one-line).pdf PDF
36C25923Q0060.docx DOCX document
36C25923Q0060_1.docx DOCX document
Equipment List.xlsx XLSX spreadsheet

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N/C

N/C N/C

N/CN/C

N /C

O

PE

N

N/C N/C

PARKED

N/C

N/C

OPEN

PARKED

N/C

N/C

N/C

N/C

N/C

N/C

OPEN

N/C

N/C

N/C

N/C

N/C

N/C

N/C

N/C

N/C

OPEN

OPEN

OPEN

OPEN OPEN

OPEN

OPEN

OPEN OPEN

N/C

OPEN

OPEN

N/C

N /C

O

PE

N

OPENOPEN OPENO

PE

N

O

PE

N

OPENN/COPEN

OPEN

OPEN

OPEN

OPEN

OPEN

O

PE

N

O

PE

N

O

PE

N

O

PE

N

O

PE

N

O

PE

N

O

PE

N

OPEN

O

PE

N

O

PE

N

O

PE

N

O

PE

N OPEN

O

PE

N

O

PE

N

OPEN OPEN

OPEN OPEN

O

PE

N

OPEN OPEN

OPEN OPEN

O

PE

N

OPEN

O

PE

N

OPEN

PARKED

PARKED

MH #22 MH #21 MH #20

MH #19 MH #18

SERVICE BY ROCKY

MOUNTAIN POWER 12.5

KV FROM HOGLE

SUBSTATION

MH #1

LOAD VFI

O.H. SW.

RACK

10000-12500KVA

OA-FA 65° C 7.7% Z

46KV/12470/7200

HIGHSIDE NO LOAD TAP

CHANGER SET ON C 46000V

SERVICE BY ROCKY

MOUNTAIN POWER 46KV

GROUNDED Y WITH

CONCENTRIC NEUTRAL

FROM EMMIGRATION

SUBSTATION

80E

15 KV

600A 15 KV

DUPLEX LOAD

INTERRUPTER

SWITCH

B1

A1

MANUALLY

OPERATED

N.C.

A B

300/5

PREFERRED

(EMIGRATION)

BLDG 41 SWITCHGEAR

1200A 1200A

STATION CLASS

ARRESTORS

N\O

LA

BLDG

SPARE

SPARE

SPARE

SPARE

SW D07

SW C07

SPARE

SPARE

SW C06

SW D06

S P

A R

E

SW D04

SW C04

KN

KN

KM

KM

SW D03

KL

KK

SW C03

KL

KK

500 KVA PAD

MOUNTED

TRANSFORMER

50A

15 KV

150A 15

KV

BLDG 3

B2 A2

LOOP FED

XFMR

BUILDING 16

BLDG 16

D1

SW CO2 SW DO2

D1

C1

KB

KB

MH D05

D1

D1

D1

D1

C1

MH C05

C1

C1

KA KA

SW DO1 SW CO1

BLDG 38 BLDG 34

KZ KA1 KZ KA1

MH D01 MH C01

C1

C1

KK

KK

C1

C1

C1

MH C04

D1

MH D04

D1

MH D03

MH C03 SW CD05

MH 14

B

LD

G

B

LD

G

S P

A R

E

SPARE

SPARE

SPARE

D1

MH D02

MH C02

C1

SPARE

EXPAND

PARKING

METAL ENCLOSED SWITCH GEAR IN

ADDITION TO BUILDING 3

2.35 MW

CHP PLANT

(BLDG #6)

SPARE D1 LOOP

SOUTH

D1 LOOP

NORTH

BLDG #16

C1 LOOP

NORTH

BLDG #16

C1 LOOP

SOUTH

SPARE GENERATOR

(FUTURE)

S E

C

TI

O N

S E

C

TI

O N

S E

C

TI

O N

S E

C

TI

O N

S E

C

TI

O N

S E

C

TI

O N

S E

C

TI

O N

S E

C

TI

O N

S E

C

TI

O N

S E

C

TI

O N

S E

C

TI

O N

S E

C

TI

O N

VAMC 15KV SWITCHGEAR 1200A OUTDOOR WALK-IN TYPE

B Y

P A

S S

B Y

P A

S S

W3 W5 W6

W2 W4 W1 W1 W2

W3 W4

W1 W2

W3 W4

W1 W2

W3 W4

C1

D1

CLOSED FOR

BACKFEED

SWITCH CLOSED TO

BACKFEED C1 & D1 LOOPS

WITH EXISTING B2 RADIAL

MH D03A MH C03A

W3

W4

W1

W2

W3

W4

W1

W2

S P

A R

E

KH

KJ

KH

KJ

V A

LO

R

H O

U S

E

FI

S H

E R

H O

U S

E

SW C13

SW D13

SW C17

SW D17

D

C

D

MH D10

MH C11

MH C12A

MH D11A

MH C11A

MH D12B

SW C17A

SW D17A

W2

W1

W3

W4

W2

W1

W2

W1

MH C10

D1

C1

MH C12MH C12B

B

LD

G

B

LD

G

MH

D12A

MH

D12

MH D11

B2 OR A2 OR D1 OR C1

S P

A R

E

15KV PRIMARY

SELECTOR SWITCH

500 KVA PAD

MOUNTED

TRANSFORMER

BUILDING 39 DWG E-8,9

MH #9MH #10MH #11

B2

A2

DWG E-8,9

BLDG 5

FO#17-90239A

MH #1 MH #2

B2

A2

B1

A1

MH #3 MH #4 MH #5 MH #6

MH #7

MH #8

B1A1

B2A2

A1B1

MH 13

MH #12

B2

A2

B1 TOP

SPARE

B2 TOP

SPARE

1200A

B2 BOTTOM

1200A

B1 BOTTOM

1200A A2

1200A

A1 SPACE SPACE

1200A

A BUS

STATION CLASS

ARRESTORS

N\C

LA

1200A

B BUS

AS5IN

KVA

XFMR

SPLICES 15KV

SPLICES 15KV

NEW 500 KVA

PAD MOUNTED

TRANSFORMER

DWG E-8,9

BLDG 8

3 #2/0 CU EP 15KV W/ #2

600V CU THW

3 #2/0 CU EP 15KV WITH 600V #2 CU THW

NEUTRAL (TYP THROUGHOUT)

DUPLEX LOAD INTERRUPTER

15KV SWITCH

600A BUS

500 KVA PAD

MOUNTED

TRANSFORMER

0A

K

V

1500 KVA PAD

MOUNTED

TRANSFORMER

A

K

V

500 KVA PAD

MOUNTED

TRANSFORMER

DWG E-3,4

300 KVA PAD

MOUNTED

TRANSFORMER

DWG E-5,7

M H

0A

BLDG 2

BLDG 27

BLDG 4

B U

IL

D

IN

G

TRAILERS

B U

IL

D

IN

G

D W

G E

-3 , 5

, 6 , 7

DWG E-5

K

V D

U P

LE

X

P R

IM

A

R Y

S E

LE

C

TO

R

S W

IT

C

H

BLDG 27

DWG E-5

K

V D

U P

LE

X

P R

IM

A

R Y

S E

LE

C

TO

R

S W

IT

C

H

3 #2/O CU EP 15KV WITH 600V #2

CU THW NEUTRAL

CENTER

TIE

EXISTING

SWITCH

S P

A R

E

KF

KG

W2

W1

W3

W4

KF

KG

W2

W1

W3

W4

C

C

C1

C1C1

C1

C1

D1

D1

D1

D1

W2

W1

W3

W4

SS01

W

W

W

W

W

W

VOLTAGE

REGULATORS

M

SW DO9

KO KT KS

SW CO9

S W

C

K E

S W

D

K E

S W

C

S W

D

K C K D

K C K D

C

D

D

C

D

C

C

D

D

D

KO KT KS

K

FK

F

BLDG 14N

BLDG 14S

B U

IL

D

IN

G

P S

W

A

0A

K

V M

R

K

V M

R

K V

A P

A D

M O

U N

TE

D

TR

A

N S

FO

R

M E

R

0V

B U

IL

D

IN

G

B U

IL

D

IN

G

R

M : G

D

-1

B

P S

W

KE KE

15kV JUNCTION BOX @ B42

A1 B1

FA

U

LT

A

V A

IL

A

B

IL

IT

Y

A T

M A

N H

O

LE

Ø

4, A

2.

K

V

S P

LI

C

E S

K V

S P

LI

C

E T

O C

O N

D U

C

TO

R

FU

R N

IS

H

E D

U N

D E

R P

R E

V

IO

U S

P R

O

JE

C T

M H

(IN

S

ID

E

W A

LK

N

O R

TH

O

F B

RETENTION BASIN

SOLAR ARRAY

FUTURE SOUTH LOT

SOLAR ARRAY

KR KQ KP KO

SW CO8

KR KQ KP KO

SW D08

SPARE

SPARE

SPARE

SPARE

SW C15

SW D15

SW C14

SW D14

KW

KW

C1

D1

MH C08

MH D08

MH C06

MH D06

D1

D1

MH C07

MH D07

C1

MH C09

MH D09 C1

C1

7D1

D1

D1

D1

C1

C1

C1

C1

C1

D1

BLDG 1 EM POWER

BLDG 44

BLDG 1 PROSTH ADD.

HENARD JR.

6563462-2202

TRUMAN

No.

NEW CAMPUS PARTIAL

ONE-LINE DIAGRAM

AS-BUILT CONDITIONS

AUGUST 22, 2016

TERM

TERM

JUNE 25, 2018

File details come from the government source that posted it. Updated .