Camp_Spearhead_-_Bathroom_Repair_2021_11_22.pdf

PDF 692 KB Posted

Attached to
FLOORING REPAIR & WATERPROOFING
Solicitation number
IFB #22048
Issued by
Greenville County, South Carolina

About this file

This architectural drawing set is a detailed plan for bathroom flooring renovation at Camp Spearhead, a Greenville County recreational facility in South Carolina. The documents specify comprehensive floor replacement procedures for Cabins C2 and C3, including removal of existing 1/2" wood subflooring, installation of new 1/2" exterior grade tongue-and-groove plywood, application of self-leveling compound, and installation of Altro Aquarius sheet vinyl flooring (SV-1) with 6" flash cove integration. The project involves reinforcing existing wood joists, applying closed-cell spray foam insulation, and maintaining existing plumbing fixtures and shower units.

The technical specifications outline precise installation requirements, including heat-welded seams, two-part epoxy adhesive for floor installation, and specific manufacturer guidelines for material selection. The flooring will be Altro Aquarius in "Otter" color, measuring 6'-7" wide, with transition strips by Johnsonite. Key notes emphasize contractor responsibilities such as protecting existing fixtures, reporting any water damage, and obtaining owner/architect approval for material samples. The drawings provide detailed wall sections, demolition plans, and flooring transition details, indicating a comprehensive approach to renovating the bathroom and shower areas while preserving the existing structural integrity of the camp facilities.

View the file

Other files

File Type Posted
FLOORING_REPAIR_&_WATERPROOFING_(Addendum_#1_Revision).pdf PDF
Sample_Contract.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WH

W /D

WH

W /D

WH

W /D

WH

W /D

1. EXTERIOR DIMENSIONS ARE TO FACE OF SIDING, UNO.

2. INTERIOR DIMENSIONS TO EXISTING WALLS ARE TO FACE OF FINISH, UNO.

3. PROTECT CEILING FINISH AND FIXTURES DURING CONSTRUCTION. CEILING

FINISH SHALL REMAIN AS IS.

GENERAL NOTES

5 6

E E

F F

5.5

NEW SUBFLOOR, SHEET VINYL SV-1

FLOORING AND INTEGRAL WALL BASE

INSTALLED TO STOP POINT.

LAVATORY

SHOWER

SHOWER

TOILET

TOILET

STORAGE /

LAUNDRY

BATHROOM

LAVATORY

SHOWER

SHOWER

TOILET

TOILET

STORAGE /

LAUNDRY

BATHROOM

USE SELF-LEVELING COMPOUND TO LEVEL THE SUBFLOOR AS

NEEDED BEFORE FINAL UNDERLAYMENT PLYWOOD LAYER IS

INSTALLED SEE A4/A-100.

SHOWER ROOMS, TOILET ROOMS, AND BATHROOMS TO

RECEIVE NEW SUBFLOOR, SEE A4/A-100.

STOP POINT FOR NEW SUBFLOOR,

FLOORING AND INTEGRAL BASE.

NOT IN

SCOPE

STOP POINT FOR NEW SUBFLOOR, FLOORING AND

INTEGRAL BASE.

A-100

A6

D4

A-100

D5

A-100

NOT IN

SCOPE

A4

A-100

STOP POINT FOR NEW

SUBFLOOR, FLOORING AND

INTEGRAL BASE.

CABIN C3 CABIN C2

NEW SUBFLOOR, SHEET VINYL

SV-1 FLOORING AND INTEGRAL

WALL BASE INSTALLED TO

STOP POINT.

STOP POINT FOR NEW

SUBFLOOR, FLOORING AND

INTEGRAL BASE.

1ST FLOOR

0' - 0"

NEW CLOSED CELL SPRAY FOAM

INSULATION AS NEEDED; INSULATION

SHALL BE APPLIED 4" THICK TO ENSURE

PROPER THERMAL R-VALUE

SV-1 ALTRO AQUARIUS SHEET

FLOORING WITH 6" FLASH COVE

INTEGRATION.

NEW 1/2" PLYWOOD C/D EXTERIOR

GRADE T & G SUBSTRATE.

EXISTING 2X12 WOOD JOISTS SHALL

REMAIN

NOTE: ALL MATERIALS USED SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. SAMPLES OF ALL FINISH SELECTIONS SHALL BE CONFIRMED BY OWNER / ARCHITECT PRIOR TO INSTALLATION.

FLOORING MUST BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS.

REINFORCE DAMAGED EXISTING 2X12

WOOD JOISTS BY SISTERING NEW

PRESSURE TREATED 2X12 WOOD JOISTS

ON EITHER SIDE SECURED NEW JOISTS

TO EXISTING JOIST WITH TIMBERLOK

SCREWS (TWO ROWS @ 16" O.C.).

NEW 1/2" EXTERIOR GRADE T & G.

SANDED FACE PLYWOOD

UNDERLAYMENT; APA TRADEMARKED

PLYWOOD OF GRADE C-C PLUGGED OR

BETTER (OR EQUIVALENT).

A-100

C4

EXISTING PLUMBING FIXTURES TO

REMAIN

FEATHERED SELF-LEVELING

COMPOUND AS NEEDED BETWEEN

PLYWOOD LAYERS.

PROVIDE SIMPSON STRONG TIES FOR

JOIST CONNECTION (VERIFY CONDITION

IN THE FIELD (TYPICAL AT LOCATIONS).

IF EXISTING WOOD JOIST IS

COMPLETELY UNSALVAGEABLE,

REPLACE AS NEEDED.

1. PRIOR TO INSTALLATION AND FABRICATION, CONTRACTOR SHALL COORDINATE

WITH ARCHITECT AND INTERIOR DESIGNER TO REVIEW ALL FLOOR PATTERNS,

FINISHES AND DOCUMENTATION INFORMATION.

2. PRIOR TO PAINTING, PAINTING CONTRACTOR SHALL SUBMIT TO

ARCHITECT/INTERIOR DESIGNER EACH PAINT COLOR FINISH ON A 8 1/2" X 11" SHEET

OF CHIPBOARD FOR PRELIMINARY APPROVAL. FOR FINAL APPROVAL BY OWNER AND

ARCHITECT PRIOR TO PAINTING, THE PAINTING CONTRACTOR SHALL VERIFY PAINT

COLOR MATCH OF EXISTING WALL FINISH.

3. INSTALLERS OF EACH FINISH MATERIAL SHALL INSPECT BOTH THE SUBSTRATE

AND CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED. INSTALLER SHALL NOT

PROCEED UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED IN AN

ACCEPTABLE MANNER TO ALL PARTIES AND MEET ALL MANUFACTURER'S

REQUIREMENTS.

4. ALL INTERIOR FINISHES SHALL COMPLY WITH SECTION 803 OF RESTRICTIONS OF

COMBUSTIBLE MATERIALS OF THE INTERNATIONAL BUILDING CODE. ALL INTERIOR

FINISHES SHALL BE CLASS B OR BETTER.

5. THE INTENT IS TO PROVIDE A COMPLETE FINISHED INTERIOR WHETHER OR NOT

SPECIFICALLY INDICATED. ITEMS SHALL BE FINISHED AND/OR PAINTED AS DIRECTED

BY DESIGNER, WHETHER OR NOT SPECIFICALLY SCHEDULED OR INDICATED ON

DRAWINGS.

6. INSTALL TRANSITION STRIP AT THRESHOLD WHERE DIFFERING FLOORING

MATERIALS ABUTT, UNLESS OTHERWISE NOTED. COORDINATE COLOR/FINISH WITH

DESIGNER.

7. ALL FLOOR FINISH CHANGES / TRANSITIONS SHALL OCCUR AT THE CENTER LINE

OF CLOSED DOORS.

8. FLOOR PATTERN TO CONTINUE UNDER ALL OPEN WOODWORK/ WORKSURFACES.

9. PRIOR TO ORDERING, SUB-CONTRACTORS FOR FLOORING, PAINTING, AND

MILLWORK SHALL SUBMIT TO ARCHITECT / INTERIOR DESIGNER AN 8" X 8" SAMPLE OF

EACH MATERIAL SPECIFIED FOR FINAL APPROVAL.

10. IF ANY DISCREPANCIES OR OMISSIONS ARE NOTED IN THESE DRAWINGS,

CONTACT INTERIOR DESIGNER OR ARCHITECT PRIOR TO ORDERING OR

COMMENCING WORK.

11. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK LEAD TIMES ON

FINISHES IN ORDER TO AVOID DELAYING WORK.

ROOM FINISH SHEET NOTES

1ST FLOOR

0' - 0"

FIBERGLASS REINFORCED PLASTIC (FRP) FINISH

SHALL REMAIN.

EXISTING WALL STRUCTURE.

EXISTING FLASH COVE CAP STRIP

EXISTING 1/2" PLYWOOD C/D EXTERIOR

GRADE T & G SUBSTRATE.

NEW 1/2" EXTERIOR GRADE T & G. SANDED FACE

PLYWOOD UNDERLAYMENT; APA TRADEMARKED

PLYWOOD OF GRADE C-C PLUGGED OR BETTER (OR

EQUIVALENT). THIS PRODUCT SHALL MEET ASTM

F1482 - 15 REQUIREMENTS.

REPLACE AS NEEDED, 1 1/2" COVE FORMER

CONTINUOUS AROUND PERIMETER WHERE

FLOORING APPLICATION MEETS VERTICAL WALLREPLACEMENT SV-1 FLOORING WITH 6" FLASH COVE

INTEGRATION.

FEATHERED SELF-LEVELING COMPOUND AS NEEDED

BETWEEN PLYWOOD LAYERS.

F L

A S

H C

O V

E

5.5

EXISTING 2X12 FLOOR

JOISTS TO REMAIN

REINFORCE DAMAGED

EXISTING 2X12 WOOD

JOISTS BY SISTERING

NEW PRESSURE

TREATED 2X12 WOOD

JOISTS ON EITHER SIDE.

SECURE NEW JOISTS TO

EXISTING JOIST WITH

TIMBERLOK SCREWS

(TWO ROWS @ 16" O.C.).

PROVIDE SIMPSON

STRONG TIES FOR

JOIST CONNECTION

(VERIFY CONDITION IN

THE FIELD (TYPICAL

AT ALL END

LOCATIONS).

E E

F F

5.5

5.5

EXISTING COUNTERTOPS, SINKS AND

FAUCETS TO REMAIN. PROTECT AS

REQUIRED DURING ALL

CONSTRUCTION ACTIVITY, TYPICAL.

EXISTING COUNTERTOPS, SINKS AND

FAUCETS TO REMAIN. PROTECT AS

REQUIRED DURING ALL CONSTRUCTION

ACTIVITY, TYPICAL.

NOTE: CONTACT OWNER / ARCHITECT IF ANY FIXTURES, WALLS, DOORS, OR CASEWORK APPEAR TO HAVE WATER DAMAGE OR BECOME DAMAGED DURING CONSTRUCTION. CONTACT OWNER / ARCHITECT IF STRUCTURAL INTEGRITY APPEARS TO BE COMPROMISED AS A RESULT OF WATER DAMAGE OR BECOME DAMAGED DURING CONSTRUCTION. ANY DAMAGES THAT OCCUR DURING CONSTRUCTION WILL BE REPAIRED AND/OR REPLACED AT NO COST TO THE OWNER.

CABIN C3 CABIN C2

STOP POINT FOR EXISTING AND

SUBFLOOR REMOVAL, TYPICAL.

STOP POINT FOR EXISTING FLOORING AND

SUBFLOOR REMOVAL, TYPICAL

LAVATORY

LAVATORY

NOT IN

SCOPE

SHOWER

SHOWER

TOILET

TOILET

BATHROOM

BATHROOM

TOILET

TOILET

SHOWER

SHOWER

REMOVE EXISTING SHEET FLOORING

AND INTEGRAL BASE TO STOP POINT

INDICATED. REMOVE DAMAGED 1/2"

WOOD SUBFLOOR TO STOP POINT

INDICATED. PROVIDE UNIT COST FOR

ADDITIONAL SUBFLOOR SQFT.

REMOVE EXISTING SHEET FLOORING

AND INTEGRAL BASE TO STOP POINT

INDICATED. REMOVE DAMAGED 1/2"

WOOD SUBFLOOR TO STOP POINT

INDICATED. PROVIDE UNIT COST FOR

ADDITIONAL SUBFLOOR SQFT.

EXISTING SHOWER UNITS TO REMAIN.

PROTECT AS REQUIRED DURING ALL

CONSTRUCTION ACTIVITY, TYPICAL.

EXISTING SHOWER UNITS TO REMAIN.

PROTECT AS REQUIRED DURING ALL

CONSTRUCTION ACTIVITY, TYPICAL.

1ST FLOOR

0' - 0"

EXISTING THRESHOLD INTO

SHOWER

CLEAR MILDEW-RESISTANT SILICONE

CAULK JOINT WHERE SHOWER FIXTURE

EDGE MEETS REPLACEMENT SV-1 SHEET

FLOORING

SHEET FLOORING TO RUN UNDER ENTRY

EDGE OF SHOWER FOR 2" MINIMUM

NEW 1/2" EXTERIOR GRADE T & G. SANDED FACE

PLYWOOD UNDERLAYMENT; APA TRADEMARKED

PLYWOOD OF GRADE C-C PLUGGED OR BETTER

(OR EQUIVALENT).

FEATHERED SELF-LEVELING COMPOUND AS

NEEDED BETWEEN PLYWOOD LAYERS

EXISTING 1/2" PLYWOOD C/D EXTERIOR GRADE T

& G SUBSTRATE.

1ST FLOOR

0' - 0"

EXISTING PLYWOOD

SUBSTRATE TO REMAIN

EXISTING 2X12 WOOD JOIST TO

REMAIN

EXISTING 1/2" PLYWOOD C/D

EXTERIOR GRADE T & G

SUBSTRATE (TOILET ROOMS,

SHOWER ROOMS, AND

BATHROOMS).

SHEET FLOORING, SV-1

NEW 1/2" EXTERIOR GRADE T & G.

SANDED FACE PLYWOOD

UNDERLAYMENT; APA

TRADEMARKED PLYWOOD OF

GRADE C-C PLUGGED OR BETTER

(OR EQUIVALENT).

FEATHERED SELF-LEVELING

COMPOUND AS NEEDED

BETWEEN PLYWOOD LAYERS

EXISTING 1/4" EXTERIOR GRADE T

& G. SANDED FACE PLYWOOD

UNDERLAYMENT; APA

TRADEMARKED PLYWOOD OF

GRADE C-C PLUGGED OR BETTER

(OR EQUIVALENT).

EXISTING SELF-LEVELING

COMPOUND AS NEEDED

BETWEEN PLYWOOD LAYERS

1. CONTRACTOR TO PERFORM DEMOLITION WORK AS REQUIRED PER WORK

SEQUENCE.

2. DEMOLITION DRAWINGS ARE INTENDED TO SHOW GENERAL AREAS OF

DEMOLITION AS WELL AS GENERAL EXISTING CONDITIONS. THEY DO NOT

SHOW ALL WORK WHICH MAY BE NECESSARY. COMPARE WITH DRAWINGS

INDICATING NEW CONSTRUCTION.

3. EXISTING WORK TO REMAIN SHALL BE TEMPORARILY SECURED, BRACED AND

STABILIZED UNTIL PERMANENT CONSTRUCTION IS IN PLACE.

4. VERIFY FIELD CONDITIONS PRIOR TO START OF DEMOLITION/CONSTRUCTION

AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.

5. VERIFY THAT CONSTRUCTION INDICATED FOR REMOVAL IS NOT LOAD

BEARING OR IS ADEQUATELY SHORED AS REQUIRED.

6. ERECT BARRICADES, FENCES OR OTHER SECURABLE MEANS TO PREVENT

UNAUTHORIZED ACCESS INTO CONSTRUCTION ZONES.

7. DO NOT ALLOW MATERIAL AND DEBRIS GENERATED BY DEMOLITION

ACTIVITIES TO ACCUMULATE ON THE JOB SITE. REMOVE DAILY AND DISPOSE

OF IN A LEGAL MANNER. NO ON-SITE SALE OR BURNING OF REMOVED ITEMS

IS PERMITTED.

8. THE CONTRACTOR MUST MAINTAIN ADEQUATE SUPPORT INSULATION,

WATERPROOFING, EMERGENCY LIGHTING, SECURITY, ALARMS, ETC. FOR ALL

OR PART OF ITEMS WHICH ARE TO REMAIN.

9. PREPARE AND PATCH SURFACES THAT RECEIVE NEW FINISHES AS REQUIRED

BY REMOVING OR RELOCATING DEVICES, WIRING OR OTHER

APPURTENANCES NO LONGER APPROPRIATE FOR THE NEW USE OF THE

ROOM.

10. MAINTAIN EXISTING FINISHES, OPERATIONAL CHARACTERISTICS, AND

APPEARANCE OF ITEMS SCHEDULED TO REMAIN OR BE REUSED.

11. ANY DAMAGE TO THE EXISTING STRUCTURE CAUSED BY THE CONTRACTOR

WILL BE REPAIRED OR REPLACED BY THE CONTRACTOR AT NO COST TO THE

OWNER.

DEMOLITION PLAN SHEET NOTES

CHECKED BY:

DRAWN BY:

DATE:

PROJECT:

REVISIONS:

MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS

A

2 3 4 5 6

B

C

D

E

COPYRIGHT 2018 ALL RIGHTS RESERVED

PRINTED OR ELECTRONIC DRAWINGS AND

DOCUMENTATION MAY NOT BE REPRODUCED

IN ANY FORM WITHOUT WRITTEN PERMISSION

FROM LS3P ASSOCIATES LTD.

WWW.LS3P.COM

TEL. 864.235.0405 FAX 864.233.4027

GREENVILLE, SOUTH CAROLINA 29601

110 WEST NORTH STREET SUITE 300

/2

/2

:3

:5

A

M

P

G S

P

C

IV

\7 \3

-2

G re e n v il le

C o u n ty R e c -C a m p S p e a rh e a d

\2 .0

D e s ig n \D ra w in g s \A rc h

G v l C o u n ty

C a m p S p e a rh e a d

.r v t

3702-218650

22 November 2021

BF

DO/AB

ENLARGED

PLANS AND

DETAILS

A-100

Pleasant Ridge - Toilet/Bath Flooring Repair and Waterproofing 2021

Permit & Construction

Camp Spearhead

1/4" = 1'-0" C1

NEW TOILET/BATHING FLOOR PLAN

1 1/2" = 1'-0" A4

WALL SECTION - NEW CONDITION @ FLOOR

3" = 1'-0" C4

DETAIL FOR FLASH COVE BASE AT WET WALL

ROOM FINISH LEGEND

MATERIAL

CODE DESCRIPTION

MANUFACTUR

ER

PRODUCT NAME

AND NUMBER

STYLE /

PATTERN FINISH COLOR SIZE INSTALLATION FORMAT / COMMENTS

REP

CONTACT

INFO NOTES

DIVISION 9 FINISHES - FLOORS

SV-1 SHEET VINYL

FLOORING

ALTRO AQUARIUS AQI2006 OTTER 6'-7"W X

66'L

INCLUDE 6"H FLASH COVING WITH COVE

CAP IN ALL AREAS. SEE C4/A-100. SV-1

SHALL RUN 2" UNDER LIP OF PREFAB

SHOWER AND SEALED WITH

ALTROMASTIC 100.

EDDIE

RUMSEY

404.275.3031

ALL SV-1 SEAMS SHALL BE HEAT

WELDED. USE TWO PART EPOXY

ADHESIVE THROUGHOUT FOR

FLOOR INSTALLATION AND A

SURFACE CLAMPING MEMBRANE

FLOOR DRAIN (BY JR SMITH OR

EQUAL) IN ALL EXISTING DRAIN

LOCATIONS. IF SV-1 SPEC. DOES

NOT ALLOW FOR BID SITUATION TO

OCCUR, SUBMIT EQUAL PRODUCT

TO INTERIOR DESIGNER FOR

CONSIDERATION.

DIVISION 10 SPECIALTIES

TS-1 TRANSITION STRIP JOHNSONITE SLIMLINE

TRANSITION

DEPENDS

ON FINAL

FINISHED

FLOOR

HEIGHTS

TOAST

USE AT SV-1 TO EXISTING WOOD

FLOORING TRANSITIONS ONLY.

EMMA

MALTBA

910.988.4167

USE AT STOP POINT TRANSITIONS

TO LAVATORY 200 AND 300.

3/4" = 1'-0" A6

TYP. FLOOR JOIST REPAIR AS REQUIRED

1/4" = 1'-0" C3

DEMOLITION PLAN: TOILET/BATHING AREA

3" = 1'-0" D4

FLOORING TRANSITION @ SHOWER

3" = 1'-0"

D5

FLOORING TRANSITION @ STOP POINTS

No. Description Date

Sheets
A-100 - ENLARGED PLANS AND DETAILS

File details come from the government source that posted it. Updated .