This document is a detailed technical specification for a Small Shelter design for the Federal Bureau of Investigation (FBI), intended for protecting high-speed camera equipment. The shelter must be a compact 3' x 3' x 3' white steel structure weighing under 9,000 pounds, with specific requirements including a 6" tall base structure, chain lifting ports or forklift points, and an offset entrance/door. Critical design features include a 6" x 6" window port accommodating a 12" x 12" x 2.5" ballistic glass panel, which must have adjustable fixtures to reposition or replace the glass if cracked, and 1/4" drop-over metal shields to protect against blast effects.
Key technical specifications mandate interior dimensions of at least 18" x 18" x 18", an upper ventilation port, two cable/power penetration ports, and a door with a single locking hasp and exterior handle. The shelter includes specialized ballistic glass mounting features such as water-resistant seals, dampening material to reduce shock transfer, and a protective cover for storage. These precise requirements align with the FBI's solicitation for custom manufactured, mobile, armored magazines designed to protect camera equipment, with a potential contract award under a brand name or equal procurement strategy.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFQ Custom Armored Magazines.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Small Shelter (x1) Requirement Shelter shall not weigh more than 9,000 pounds Shelter shall include a base structure that is 6" tall Shelter shall include chain lifting ports for mobility, or shall include standard ARMAG fixed forklift points on the top of the shelter running side wall to side wall to allow transport with a telescopic handle
Shelter exterior shall be white Shelter exterior shall be 1/4" steel Shelter does not require external grounding Exterior dimensions shall be 3' x 3' x 3'
Shelter shall include one upper ventilation port
Shelter exterior shall include two penetration as entrance/exit port for camera cables and power
Interior Dimensions Interior dimensions shall be no smaller than 18" x 18" x 18"
Window port shall be 6 inches by 6 inches Shelter shall have 1 window port on opposite wall of entrance/doorway The window port shall be centered on the front wall
The window port shall accommodate a 12" x 12" x 2.5" piece of ballistic glass (ballistic glass provided by TIEDS Center)
The ballistic glass must be secured to the shelter at the window port with seals to protect the interior of the shelter and cameras from water damage (Must preview design)
Dampening material shall be used to protect the ballistic glass from shock transfer between the shelter and the glass (Must preview design)
Overall
Exterior
Exterior Openings
Window Ports
The shelter shall include ballistic glass fixtures that allow the glass to be adjusted in location such that if the ballistic glass develops a crack, it can be repositioned and resecured moving the crack out of the way of the 6" x 6" window port (Must Preview Design)
The fixtures must also allow for the replacement of ballistic glass at the end of its life (Must Preview Design)
Shelter shall include a not in use cover to protect the exposed ballistic glass when shelter is stored (Must Preview Design)
The fixtures shall be fitted with 1/4" drop-over metal shields/decoupling metal plates to protect the glass from blast effects and explosive fragmentation (Must Preview Design)
Shelter entrance/door shall be offset to accommodate pipe penetration
Shelter door shall be securable with a single locking hasp
Shelter door shall include a handle on the outside of the door
Shelter Entrance/Door