Camera Locations on CBOC Floor Plans Revision 2 for Submission.pptx
PPTX presentation 20 MB Posted
- Solicitation number
- 36C25625Q0624
About this file
This PowerPoint file contains detailed camera location and configuration specifications for eight Community Based Outpatient Clinics (CBOCs) across Arkansas for the VA Veterans Health Administration. The document, part of Solicitation Number 36C25625Q0624, provides a comprehensive Revision 2 overview of security camera placement, including specific technical details for each location such as camera types, viewing angles, and installation methods.
Key specifications include: 270-degree view cameras on exterior building corners (with some exceptions), indoor and outdoor dome cameras (2mp and 5mp), License Plate Recognition (LPR) cameras, and consistent installation protocols involving mounting in eaves, awnings, or walls. Each CBOC (Conway, El Dorado, Hot Springs West/East, Mena, Pine Bluff, Searcy, Russellville, and Mountain Home) has unique camera configurations, with some locations removing existing cameras and adding new ones. Camera routing typically involves second-floor access to OIT (Office of Information Technology) rooms or closets, with cable penetration through brick, eaves, or walls. The project focuses on enhancing security surveillance across these VA healthcare facilities.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| amendment 5.docx | DOCX document | |
| amendment 04.docx | DOCX document | |
| 36C25625Q0624 0003.docx | DOCX document | |
| amendment 002.docx | DOCX document | |
| 36C25625Q0624 Rev 1.docx | DOCX document | |
| 36C25625Q0624.docx | DOCX document | |
| CBOC Security Camera SOW Revision 3 Highlighted to show Changes.docx | DOCX document | |
| WD Jefferson County.pdf | ||
| WD Baxter County.pdf | ||
| WD Polk County.pdf | ||
| WD White County 02.pdf | ||
| WD Pope County.pdf | ||
| WD Faulkner County.pdf | ||
| CBOC Security Camera SOW Revision 3.docx | DOCX document | |
| WD Union County.pdf |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Conway CBOC Revision 2 Camera Viewing Direction
FD9383-HTV
FE9391-EHV-V2
FD9166-HNF2
PNO-A9311R
LPR Camera
95’
65’ 70’
MA9322-EHTVL
Summary of changes.
Cameras on exterior corners of building are 270-degree view with 1 exception. See note 2 below.
Camera on Right front corner is changed from a 270-degree view to only 5mp IR outdoor dome, view angle is 90-degrees.
Camera added to Room 151 2mp indoor doom camera. Place camera in corner of entrance.
Installation note: Camera mounted in front entryway of building that have the camera mounted in the brick directly under the awning with penetration through the brick. Second floor access to route cabling to OIT room.
69’ Approximate distance to OIT closet
New Door
83’ 35’ 111’ 55’
OIT Room
Conduit on flat roof Above door to center camera
El Dorado CBOC
FD9383-HTV
Camera Viewing Direction
MA9322-EHTVL
80’ Summary of changes.
Cameras on exterior corners of building are 270-degree view.
Camera added to Room 146. fisheye indoor camera.
Camera mounted in front entryway of building that have the camera mounted in the hollow eave directly under the awning with penetration through the eave. Second floor access to route cabling to OIT room.
OIT Room (NVR) In attic
74’ 35’ 74’ 74’ 80’ 74’
Camera mounted in eave just above brick
Hot Springs West Bldg. CBOC Revision 2
OIT room
74’ 70’ 75’ 50’ 78’
71’ Summary of changes.
Cameras on exterior corners of building are 270-degree view.
Camera mounted in front entryway of building that have the camera mounted in the hollow eave directly under the awning with penetration through the eave. Second floor access to route cabling to OIT room.
Courtyard camera was removed from the West building and will be located in the East building.
Corridor to East building
West Bldg.
90’
Hot Springs East Bldg. CBOC Revision 2
Summary of changes.
Cameras on exterior corners of building are 270-degree view.
Camera mounted in front entryway of building that have the camera mounted in the hollow eave directly under the awning with penetration through the eave. Second floor access to route cabling to OIT room.
Courtyard camera was removed from the West building and will be located in the East building.
OIT room (NVR) 70’ 78’
75’
Courtyard Corridor to West building 69’ Approximate distance to OIT closet
PNO-A9311R
East Bldg.
Mena CBOC
LPR Cameras
178’ 159’
FD9383-HTV
Summary of changes.
Cameras on exterior corners of building are 270-degree view Except for the camera on the left front of building. Due to a tree obstruction, a 5mp IR outdoor dome will be mounted on the side of the building approximately 3 feet from the corner. This will replace the 270-degree camera earlier depicted.
An additional 5mp IR outdoor dome camera will be mounted on the pillar hollow eave, to view the corner with the tree obstruction.
Installation Note: Camera mounted in front entryway of building that have the camera mounted in the hollow eave directly under the awning with penetration through the eave. Second floor access to route cabling to OIT room.
74’ 70’ 64’ 83’
34’
Camera on column
Pine Bluff CBOC
-Remove Existing Cameras (9), NVR (1) & Wiring 7 interior cameras & 2 exterior cameras (Place in box to give to building owner)
FD9166-HNF2
105’ 111’
110’ 127’ 95’ 90’ 84’ 74’ OIT Room in attic Summary of changes.
Cameras on exterior corners of building are 270-degree view.
Camera mounted in front entryway of building that have the camera mounted in the hollow eave directly under the awning with penetration through the eave. Second floor access to route cabling to OIT room.
just above the door
Searcy CBOC
Physical Therapy
OIT Room 85’ 70’ 75’ 85’ 105’ 105’ 85’
89’ 136’
85’ Summary of changes.
Cameras on exterior corners of building are 270-degree view.
Camera mounted in front entryway of building that have the camera mounted in the hollow eave directly under the awning with penetration through the eave. Second floor access to route cabling to OIT room.
Camera in Phyiscal Therapy was removed.
Camera near room 74 lab area was removed.
Camera in break room was removed Camera in corridor near room 88 was changed from a 2mp IR indoor dome to a fisheye camera.
2 5mp Exterior Cameras outside of rooms 59 and 25 were removed.
2 exterior 270-degree cameras were replaced with 5mp IR outdoor dome near room 35 and 36.
Add LPR camera to view entrance hidden by trees
Russellville CBOC
FE9391-EHV-V2
216’ 228’ Summary of changes.
Cameras on exterior corners of building are 270-degree view.
Camera mounted in front entryway of building that have the camera mounted in the hollow eave directly under the awning with penetration through the eave. Second floor access to route cabling to OIT room.
Exterior Camera outside of room 149 was removed 5MP IR outdoor dome.
OIT Room (NVR) 88’ 60’ 58’ 60’
Mountain Home CBOC
62’ Summary of changes.
Camera is surface mounted in front entryway of building on the wall above the door with a sleeve to penetrate the drop ceiling tile space. Race ways available throughout the building.
Fisheye Camera in Physical Therapy room was removed.
LPR camera was moved from the building across the driveway and mounted to the same building as the clinic.
Closed closet
Open hallway to inside of mall Open hallway to mall image1.png image2.png image3.png image4.png image5.png image6.png image7.png image8.svg image11.png image12.png image13.png image14.png image70.png image9.png image10.png image15.png image16.png image17.png image18.png image19.png image20.png image21.png image22.png image23.png image24.png image25.png image26.png image27.png image28.png image29.png image30.png image31.png image32.png image33.png image34.png image35.png image36.png image37.png image38.png image39.png image40.png image41.png image42.png image43.png image44.png image45.png image46.png
File details come from the government source that posted it. Updated .