This Request for Qualifications (RFQ) document issued by the Calcasieu Parish Police Jury in Louisiana seeks on-call engineering design and consulting services for various capital improvement projects within the Parish's Capital Improvements Projects (CIP) Program. The Parish will award one or more qualified engineers to provide professional engineering services on an as-needed basis, with the selected engineer(s) coordinating with the Parish Project Manager. Sealed qualification statements are due by 2:00 p.m. Central Time on Wednesday, November 4, 2026, with public opening at the Calcasieu Parish Government Building in Lake Charles, Louisiana. The contract will have an initial one-year term commencing upon execution through December 31, 2027, with automatic renewal options for two additional one-year periods at the same prices, terms, and conditions. Responses must address three evaluation criteria: Firm History and Relevant Project Experience (0–30 points), Capacity to Perform (0–35 points), and Qualifications of Key Personnel (0–35 points), for a maximum of 100 points.

Compensation will be provided according to the Parish's hourly rate schedule (Exhibit B) not to exceed $150,000 for the initial contract term, with the same cap applying incrementally to each renewal period. All hourly billing must include sufficient detail identifying daily time by employee and service descriptions; no markup is permitted for subcontractor services billed on an hourly basis. The Parish will issue task orders for specific projects and anticipated scopes of work once the project selection process is complete. Engineers must comply with all applicable design standards, including LA DOTD specifications and standards, and implement a Quality Assurance/Quality Control program. The Parish reserves the right to award the contract to multiple engineers if determined to be in the Parish's best interest, reject any or all proposals, or cancel the RFQ. All proposals and materials become the property of the Parish and will be retained; costs incurred by engineers in proposal preparation are the engineer's responsibility and will not be reimbursed.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Request for Qualifications for On-Call Engineering Design and Consulting

Services for Various Capital Improvement Projects

Calcasieu Parish Police Jury

RFQ Number: RFQ-2026-ENG-160

Sealed Qualification Statements will be received by:

THE PURCHASING AGENT

1015 PITHON, PARISH GOVERNMENT BUILDING, 1ST FLOOR

LAKE CHARLES, LOUISIANA 70601

Until

2:00 P.M., Central Time Zone

Wednesday, November 4, 2026 Advertisement in the Official Journal

LAKE CHARLES AMERICAN PRESS

Please read the updated Request for Qualification instructions on the following pages carefully.

REQUEST FOR QUALIFICATIONS (RFQ)

FOR ON-CALL ENGINEERING DESIGN AND CONSULTING

SERVICES FOR VARIOUS CAPITAL IMPROVEMENT PROJECTS

SECTION I. ADMINISTRATIVE AND GENERAL INFORMATION

1.1 Purpose of RFQ

The Calcasieu Parish Police Jury, herein referred to as the “Parish,” is accepting proposals/qualification statements for On- Call Engineering Design and Consulting Services for Various Capital Improvement Projects as needed to support the Capital Improvement Program. The intent of this Request for Qualification, herein referred to as “RFQ,” is to award an Engineer or more than one (1) Engineer who will be contracted under a general retainer to perform engineering-related services on an as-needed or “on-call” basis. The Engineer(s) will be required to coordinate with the Parish Project Manager.

The Parish reserves the right to award this RFQ to multiple Engineers if it is in the best interest of the Parish. The resulting contract will be for an initial one (1) year term with the option to renew for two (2) subsequent years at the same prices, terms, and conditions for a possible total of a three (3) year contract.

1.2 Proposal\Qualification Statement Submission and Delivery Instructions

Engineers are to submit their response utilizing one (1) of the delivery options below:

A. Paper proposals/qualification statements may be delivered by hand or courier service prior to the RFQ opening to our physical location as follows:

Calcasieu Parish Police Jury

Purchasing Department 1015 Pithon Street, Third Floor

Lake Charles, LA 70601

Each Engineer submitting a paper proposal/qualification statement should include: One (1) original (stamped "original") and one (1) electronic copy (USB flash drive only) in Portable Document Format (PDF). The flash drive becomes the property of the Parish. Costs incurred in the preparation and submittal of proposals/qualifications statements are the responsibility of the Engineer and will not be reimbursed.

B. Proposals/Qualification statements can also be submitted online through www.calcasieu.gov via BidExpress

(www.bidexpress.com). New accounts for electronic bidding can take several days before they are active. Please contact Bid Express for more information on the timeline for new accounts at support@bidexpress.com or 1-888- 352-2439.

The Engineer is solely responsible for the timely delivery of the proposal/qualification statement. Failure to meet the opening date and time will result in rejection of the proposal/qualification statement. The Parish is not responsible for any delays caused by the Engineer’s chosen means of proposal delivery.

Proposals/Qualification statements shall be opened publicly, and only the name of the Engineers submitting proposals/qualification statements shall be identified aloud. The proposals/qualification statements will be opened at the date and time specified in the advertisement. The opening will take place at:

Government Building

1015 Pithon Street, First Floor Lake Charles, LA 70601

RFQ-2026-ENG-160

1.3 RFQ Contact Person(s)

All questions should be submitted in writing no less than seven (7) days prior to the opening of proposals/qualification statements. Questions received within seven (7) days of the opening may not be accepted or addressed. All questions should be submitted in writing and be addressed to both:

Anais Rhodes, P.E. Kristie Cumberland, CPPB, CPPO, NIGP-CPP Project Engineer Purchasing Agent Division of Engineering Division of Finance E-mail: arhodes@calcasieu.gov E-mail: kcumberland@calcasieu.gov

1.4 Proposal\Qualification Statement Response Format

Engineers should address the questions or requests for information listed under the “Qualification Evaluation Criteria” below and should address them in the order in which they are presented. Engineers are to indicate in their proposal which item number is being answered so that proposals can be evaluated accordingly. Proposals/Qualification statements that are not in order, or that are difficult to understand may be rejected.

1.5 Errors and Omissions in Proposal/Qualification Statement

The Parish will not be liable for any error or omission in the proposal/qualification statement. The Engineer will not be allowed to alter proposal/qualification statement documents after the deadline for submission. The Parish, at its option, has the right to require clarification or additional information from the Engineer.

1.6 Changes, Addenda, or Withdrawals

The Parish reserves the right to issue Addenda to the RFQ at any time to make clarifications or adjustments. The Parish also reserves the right to cancel or reissue the RFQ.

If the Engineer would like to submit recommended changes, questions, or inquiries prior to the proposal/qualification statement opening, please submit this request in writing to the RFQ contacts listed above. All responses to questions and changes to this RFQ package will only be made via a written addendum issued by the Parish to potential Engineers. All issued addenda should be acknowledged by being signed by an authorized representative of the Engineer and submitted with the proposal/qualification statement response.

1.7 Proposal/Qualification Statement Rejection

Issuance of this RFQ in no way constitutes a commitment by the Parish to award a contract. The Parish reserves the right to accept or reject any or all proposals/qualification statements submitted or to cancel this RFQ if it is in the best interest of the Parish to do so.

1.8 Ownership of Proposal/Qualification Statement

All proposals/qualification statements and materials submitted by the due date and time specified will become the property of the Parish. Selection or rejection of a response does not affect this right. All proposals/qualification statements opened will be retained by the Parish and not returned to the Engineers. Proposals received after the due date and time specified will not be accepted or considered for award and will be returned unopened to the Engineer.

The Parish is not liable for any costs incurred by prospective Engineers prior to issuance of or entering into a contract.

Costs associated with developing the proposal/qualification statement, preparing for oral presentations (if requested), and any other expenses incurred by the Engineer in responding to the RFQ are entirely the responsibility of the Engineer and will not be reimbursed in any manner by the Parish.

1.9 Contract Terms

A sample copy of the Parish contract is attached. This sample contract is subject to change at the Parish’s discretion when deemed necessary. There are certain contractual requirements are non-negotiable including, but not limited to, audit and retention of records, governing law, non-appropriation language, and termination provisions. The Parish will work with the selected Engineer on the final contract terms, including any proposed costs that are negotiated for reasonable cost purposes.

1.10 Compensation

The Parish will provide the Awarded Engineer(s) with the specific project(s) and the anticipated scope of work, including any additional services (if applicable) for each project once the Parish’s project selection process is complete. The Awarded Engineer will be compensated in accordance with the Parish’s rate schedule attached as Exhibit B. All hourly billing must be in sufficient detail to identify daily time by employee and description of services performed. The Awarded Engineer may utilize sub-contractors if approved in advance in writing by the Parish Project Manager for that assigned project/task. The Awarded Engineer shall not mark up the sub-contractor’s fee but must utilize hourly fees for any necessary coordination with the sub-consultant.

The Engineer agrees to the use of the Parish Rate Schedule (See Exhibit B) by submitting a proposal for this Request for Qualification.

1.11 Use of Subcontractors

While the Engineer will be responsible for all deliverables referenced in this RFQ regardless as to the use of subcontractors, the use of subcontractors are to be disclosed and approved by the Parish. If the use of subcontractors is approved by the Parish, any information required of the Engineer under the terms of the RFQ is also required for each subcontractor, and the subcontractors will agree to be bound by the terms of the contract. The Engineer will assume total responsibility for compliance. Subcontractors are not required to be identified in the qualification statement response.

1.12 Evaluation of Proposals/Qualification Statements

Responses to this RFQ will be evaluated by a Review Committee consisting of Parish staff in accordance with the following criteria and corresponding point system. Responses should include information specifically addressing the selection criteria. Information furnished should reference the selection criteria number.

Engineers or their agents are prohibited from lobbying members of the Police Jury, review committee, or other staff on this project. Failure to comply with this clause will be grounds for rejection of their proposal/qualification statement as non-responsive.

As previously stated, the Parish reserves the right to accept or reject any or all proposals/qualification statements received and reserves the right to make an award without further discussion of the proposals/qualification statements submitted.

Therefore, the proposals/qualification statements should be submitted initially in the most favorable manner. It is understood that the proposal/qualification statement will become part of the Parish’s official file without obligation to the Parish. Upon opening, proposals/qualification statements become public record and may be subject to public disclosure.

Engineers are to address the questions or request for information listed under the “Qualification Evaluation Criteria” below. Engineers are to indicate in their proposal/qualification statement which item number is being answered so that proposals/qualification statements can be evaluated accordingly. Proposals/Qualification statements that are not in order, or that are difficult to understand, may be rejected.

Qualification Evaluation Criteria:

Proposals/Qualification statements will be evaluated and scored in accordance with the criteria detailed below.

Engineers may score a total of one hundred (100) points based on responses to the questions/request for information for the criteria listed below. Specific information requested per criteria listed can be found in Section III. below.

a.) Firm History and Relevant Project Experience 0 – 30 Points b.) Capacity to Perform 0 – 35 Points c.) Qualifications of Key Personnel 0 – 35 Points

1.13 Contract Negotiations, Award, and Execution

As previously stated, the Parish reserves the right to enter into contract and/or contract negotiations without further discussion of the proposals/qualification statements submitted based on the initial offers received. The RFQ, any addendums, and the proposal/qualification statement of the selected Engineer will become part of any contract initiated by the Parish. As previously stated, the Parish reserves the right to award a contract to more than one (1) Engineer and reserves the right to issue a new RFQ in the future or simply contract for services outside of any formal procurement, if deemed necessary.

In no event is an Engineer to submit its own standard contract terms and conditions as a response to this RFQ. The Engineer needs to address the specific language in the sample contract and submit with their proposal any requested contract deviations that their firm wishes to negotiate. The terms for the sample contract may be negotiated as part of the negotiation process, with the exception of contract provisions that are non-negotiable. Other negotiations may include revision of non-mandatory terms, conditions, and requirements.

Due to timing issues, the Police Jury may take formal action to award the RFQ to the Engineer that will be the most advantageous to the Parish, all factors considered. Whether an award is made or not by the Parish, if, for any reason, the Engineer, whose proposal/qualification statement is most responsive to the Parish’s needs, does not agree to the terms of a contract, that proposal/qualification statement may be rejected, and the Parish may negotiate with the next most responsive Engineer. The final contract form will be reviewed and approved by the Parish and executed by both parties.

1.14 Insurance Requirements

The Engineer will comply with the insurance requirements specified in the attached document. Prior to executing the contract, the Awarded Engineer will provide a Certificate of Insurance to the Parish showing evidence of compliance with all insurance requirements. The Parish reserves the right to require complete certified copies of all required policies at any time.

SECTION II. SCOPE OF SERVICES

As previously stated, the Awarded Engineer(s) will be responsible for providing professional On-Call Engineering Design and Consulting Services for Various Capital Improvement Projects. The Parish will provide the Awarded Engineer(s) with the specific project and the anticipated scope of work, including any additional services (if applicable) for each project/task once the Parish’s project selection process is complete.

The Engineer shall provide all materials, equipment, and labor and perform all the work required to accomplish the designated scope of work in a thorough and workmanlike manner to the satisfaction of the Parish and in accordance with the “Procedure Manual for Design Projects Performed by Architects or Engineers – revised November 2021” (attached as Exhibit A). The Parish Project Manager will issue task orders for services as appropriate. In addition to basic services, task orders may be issued for additional services that may be required for the project.

All design shall be completed in accordance with the latest edition of applicable design standards including, but not limited to, the following:

1. LA DOTD Standard Specifications for Roads and Bridges (2026)

2. American Association of State Highway and Transportation Officials (AASHTO) Policy on Geometric Design of

Highways and Streets

3. Louisiana Department of Transportation (LA DOTD) Design Standards

4. LA DOTD Drainage Design Manual (latest version)

5. Manual on Uniform Traffic Control Devices (latest version)

6. LA DOTD Traffic Engineering Manual

7. Highway Safety Manual

8. LA DOTD Engineering and Standards Manual

9. Recommended Standards for Wastewater Facilities (Ten States Standards)

10. Recommended Standards for Water Works (Ten States Standards)

11. Louisiana Administrative Code, Title 51

12. “Engineer and Architect Procedure Manual for Design Projects Performed by Architects or Engineers,”

(Manual), February 2021

Potential Task for Services may include, but not limited to:

Meetings:

1. Kick off meeting to discuss scope and additional meetings throughout the design (as necessary). Meetings may be in person or conducted virtually through Microsoft TEAMs.

2. Field meetings which can include but are not limited to: plan in hand, utility coordination, right-of-way meetings with residents, etc.

Data Collection (Survey/Geotechnical/Boundary Platting):

1. The Engineer may be responsible for the collection of field data necessary to support the hydrologic and hydraulic analysis of this project as well as support the need for the development of Engineering Design and Construction Documents.

2. The Engineer may be responsible for collecting survey data necessary for the establishment of channel cross sections needed for analysis and design.

3. The Engineer may be responsible for obtaining the necessary geotechnical soil borings to determine information to support the design (piles, bedding material, roadway cross section, etc.). Geotechnical data obtained may consist, but is not limited to, ground water elevation, soil type, and consolidation parameters.

4. The Engineer may be responsible for obtaining existing property information for the establishment of existing property boundaries and the development of property plats needed should property acquisition or easements be required for this project.

5. The Engineer will be responsible for utilizing Louisiana 811 One Call for any field investigation prior to field work. The Engineer shall identify all utilities within the project area including planar location and depth of utility.

H&H Analysis and Report:

1. The Engineer may be responsible for performing a hydrologic and hydraulic (H&H) analysis to determine the effects of water levels along drainage infrastructure (no adverse impact).

2. Establish drainage basin data and determine peak flows for the 2, 10, 25, 50, and 100-year flood events based on the most recent data for natural stream and river crossings or in the absence of data, appropriate hydrologic modeling techniques.

3. Perform water surface profile analysis using Hydrologic Engineering Center River Analysis System (HEC-RAS) hydraulic computer model or other method approved by the Parish or LA DOTD for the above-referenced range of peak flows. If the Engineer is performing bridge design, an analysis will be required for the existing and proposed bridges on natural waterways.

4. Determine bridge/culvert length and orientation and incorporate into plans on natural stream, river crossing, roadside laterals, or cross drains.

Environmental Review:

1. The Engineer may be responsible for performing a “desktop” analysis within the limits of the project improvements to determine the existence (if any) of any environmentally sensitive attributes on site that may include threatened or endangered species, sensitive cultural resources, etc.

2. This task shall document such findings by preparing a formal report.

Site Inspections:

1. Field investigation of the project area. Report on findings to determine path forward that may include photos, inspection reports, measurements, etc.

2. Other various inspections may be requested throughout design or the construction of the project.

3. All site inspections shall include a report of any findings, discussions, and other pertinent information.

Utility Coordination:

1. Plot existing and proposed utilities.

2. Identify potential conflicts with existing utilities.

3. Coordinate with utility companies for relocation of utilities attached to existing bridges or proposed roadway conflicts.

Utility Design:

1. Analyze project requirements and client specifications.

2. Design and layout water and sanitary sewer utility systems.

3. Preparation of water or sanitary sewer construction plans, profiles, and details.

4. Review compliance with relevant codes, standards, and regulations.

5. Analyze land use, population density, and anticipated growth.

6. Evaluation of hydraulic and hydrologic factors affecting service area coverage.

7. Review incorporation of future expansion and development considerations.

8. Generation of maps, diagrams, and reports for service area representation.

Roadway Alignment:

1. Prepare roadway typical sections.

2. Design and plot horizontal and vertical alignments, maintaining positive roadside drainage.

3. Plot cross-sections, including roadside drainage ditches or lateral crossings as needed.

4. Determine preliminary earthwork quantities.

5. Plot catchpoints and determine right-of-way requirements, if applicable.

6. Evaluate and determine on-site detour needs, design detour typical section and alignment, if applicable.

Bridge or Drainage Structure Design:

1. Establish horizontal and vertical clearances required.

2. Determine available structure depth and out-to-out length of the structure.

3. Determine possible span configurations. (Skew, Box Culvert, Etc.)

4. Select structure type for recommendation.

5. Prepare general layout and special detail sketches for the recommended structure type. In general, the Engineer will prepare bridge layouts similar to the latest version of the LA DOTD Bridge Plan Sheets to provide some uniformity.

6. Analyze minor drainage structure needs and size culverts.

Design Reports:

1. Submit various technical reports and/or memorandums if applicable to the Parish for review and record.

2. Preliminary Hydraulics report, including input data and output files on electronic PDF.

3. Geotechnical reports and recommendations based on field investigations.

4. Preliminary geometric alignment general layout for review and comment.

5. Prepare engineer’s estimate. Item numbers, descriptions, units, quantities, and extensions will be submitted in a format acceptable to the Parish.

Engineering Plans:

1. Provide standard plan details, if necessary.

2. Provide special details and specifications for special items not available from LA DOTD website or provided by the Parish.

3. Provide drawings using a compatible AutoCAD version.

4. Submit 11”x17” plan set via PDF for review and comment.

5. Revise plans, special provisions, cost estimate, design notes, and quantities based on the Parish review and comment.

Engineer Review/Oversite for Bidding and Construction:

1. The Engineer may be required to provide services to assist the Parish with specifications and addendum responses.

2. Review for compliance with design concepts, shop and erection drawings submitted by contractor, as needed.

3. Review laboratory, shop, and mill test reports on materials and equipment, as needed.

Permitting:

1. The Engineer may be responsible for coordinating and applying for all permits that may be necessary for the project to be constructed.

2. This task may include permitting with the U.S. Army Corps of Engineers, Louisiana Department of Wildlife and Fisheries, and local permitting authorities.

3. The Engineer may be responsible for any utility coordination within the project area, including but not limited to utility relocation oversite, utility contact notes, utility plan incorporation into deliverables, and any additional permits required.

Right-of-Way:

1. The Engineer may be responsible for identifying any right-of-way necessary to acquire to build the project, whether permanent or temporary for construction.

2. The Engineer will provide title reports for the properties identified within the project limits.

3. The Engineer may be responsible for calculating potential costs of permanent right-of-way acquisition or temporary right-of-way acquisition needed for the project.

4. The Engineer may be responsible for developing exhibits to identify the properties necessary for acquisition.

Resident Inspection:

1. The Engineer may be responsible for providing on-site inspection services during construction to ensure the contractor is constructing the project in accordance with the contract documents.

2. The Engineer will provide an on-site inspector at a frequency necessary to support adequate quality control of the construction of the project.

3. The Resident Inspector will document visual inspection by preparing a daily report of inspection witnessed as well as taking adequate photos documenting construction activities during the inspection.

4. The determination of the need for a Resident Inspector will be made by the Parish.

Additional Requirements and Miscellaneous Items:

Electronic Deliverables

The Engineer hereby agrees to produce electronic deliverables in PDF format with each hard copy submitted. The Engineer is also responsible for ensuring that sub-consultants submit required electronic deliverables in conformance with the same standards. Electronic deliverables shall include all final reports, drawings, maps, appraisals, and other similar final documents.

The Engineer shall provide electronic deliverables at each plan delivery milestone.

Quality Assurance/Quality Control

The Parish requires the Engineer to implement a Quality Assurance/Quality Control (QA/QC) program in order to provide a mechanism by which all reviews can be subject to a systematic and consistent quality check. The Engineer must ensure quality and adhere to established design policies, procedures, standards, and guidelines in the preparation and review of all CAD files/drawings. Documentation of the Engineer’s implementation of its QA/QC program, such as executed review checklists, shall accompany each invoice for services.

Items to be Provided by the Parish

In addition to any services previously indicated to be performed by the Parish, the following services and data shall also be provided, as available.

1. Relevant background information – inspection data, maintenance reports, as-built plans, etc.

2. Survey data and services as needed.

3. Geotechnical services, investigations, and reports as needed.

4. Latest hydrologic models for Calcasieu Parish watersheds.

SECTION III. QUALIFICATION EVALUATION CRITERIA

Proposals/Qualification statements will be evaluated and scored in accordance with the criteria detailed below. Engineers may score a total of one hundred (100) points based on responses to the questions/request for information listed below.

Firm History and Relevant Project Experience………...…………………………….….………………. (0 – 30 Points)

This section should contain relevant past project experience on similar projects. Project experience descriptions are not limited to past Parish projects. The Engineer’s project experience description should be limited to six (6) relevant projects, with a maximum of one (1) page per project. Project information should include: Engineer’s primary point of contact for each project; the scope of professional services provided; the value of the professional services contract; latest estimate of construction cost or final costs; and date completed or estimated completion date.

Provide background information about the Engineering firm and its general knowledge and experience in providing similar products and services as requested herein.

Please respond to the questions/requests for information below in the order in which they are asked:

a. Describe your company’s number of years of experience and the size of your firm.

b. Has the Engineer been terminated from a contract within the past five (5) years? If so, please include client information, contact number, and reason for termination.

c. Has the Engineer failed to complete any work awarded to them? If so, where, why, and when?

d. Has the Engineer, its principles, officers, or predecessor organization ever been disbarred or suspended from bidding federal, state, or local government agency projects during the past five (5) years? If yes, provide details.

e. List and describe all criminal, civil, and disciplinary hearings concerning business-related offenses in which the Engineer, its principles, officers, or predecessor organization(s) were defendants within the last five (5) years.

f. The Engineer will provide at least three (3) current and three (3) past client references, including point of contact and telephone numbers for any corporate customers or governmental agencies.

Capacity to Perform…………………………………….………………………………….…………….. (0 – 35 Points)

The Engineer will submit satisfactory evidence that he/she has the ability and capacity to perform the services required by this RFQ. Describe the methodologies to be used in meeting the requirements of this RFQ.

a. How has your firm met these objectives with past performance?

b. Please include specific examples of past performance on similar projects.

c. Please describe your experience with disaster-related projects.

d. Please provide evidence that you possess the assets, financial resources, and organizational structure necessary to perform the type, magnitude, and quality of work, as may be required in this RFQ, along with current and anticipated future workloads.

Qualifications of Key Personnel …………………….……………..……………………..………………...(0 – 35 Points)

Describe your management plan to include qualified staffing, flexibility, and commitment to fulfill the scope of work requirements. Describe the qualifications and experience of key personnel that will provide these services, including demonstrated knowledge and understanding of the types of services to be performed; previous experience in similar or related work; local codes, laws, and regulations governing the work.

a. Who will be managing the project, and how will it be managed? Who is the main point of contact? Please provide contact information.

b. Please provide the resumé (s) of the key personnel that will be assigned this project.

Total Possible Points ......................................................................................................................................... 100 Points

QUALIFICATION STATEMENT FORM

CALCASIEU PARISH POLICE JURY

PARISH OF CALCASIEU, LOUISIANA

Please read the entire Request for Qualifications (RFQ) carefully and ensure that all requirements have been addressed. By signing this form, the Proposer certifies compliance with all Instructions to Proposers, terms, conditions and specifications, and further certifies that this qualification statement is made without collusion or fraud. This proposal/qualification statement is to be manually signed in ink by a person authorized to bind the Proposer. All qualification information shall be made with ink or typewritten. Any cost incurred by the Proposer in preparing or submitting the Qualification Statement are the responsibility of the Proposer and will not be reimbursed by the Calcasieu Parish Police Jury. This Qualification Statement Form must be submitted electronically via Bid Express or signed and included with the sealed proposal/qualification statement package.

COMPANY:

MAILING ADDRESS:

SIGNATURE OF AGENT: (Must be Signed) DATE:

PRINTED AGENT’S NAME:

FEDERAL I.D. NUMBER: TELEPHONE:

FAX NUMBER: E-MAIL ADDRESS:

INTERNET HOME PAGE:

PROFESSIONAL ENGINEERING CONTRACT

BETWEEN THE

CALCASIEU PARISH POLICE JURY

AND

STATE OF LOUISIANA

PARISH OF CALCASIEU

THIS AGREEMENT is hereby made and entered into this ______ day of ___________, 2027, by and between the CALCASIEU PARISH POLICE JURY, hereinafter referred to as "PARISH," a political subdivision of the State of Louisiana, represented herein by its duly authorized President, _______________, and _____________, hereinafter referred to as “ENGINEER,” and represented herein by its duly authorized ______________________(Title), ______________(Name).

WHEREAS, the PARISH has solicited and received qualification statements for On-Call Design and Consulting Services for Various Capital Improvement Projects, identified as RFQ-2026-ENG-160, which is the legal responsibility of the PARISH;

WHEREAS, the PARISH has duly awarded the ENGINEER the referenced services as hereinafter set forth and in accordance with all local, state and federal regulations governing the expenditure of public funds not to exceed the established contract amount discussed in Section 3 below;

WHEREAS, the PARISH considers the public benefit of receiving competent professional engineering services for the above referenced project to be proportionate to the costs associated with this activity; and

WHEREAS, the ENGINEER shall provide all materials, equipment and labor and perform all the work required to accomplish the designated scope of work in a thorough and professional manner to the satisfaction of the PARISH and in accordance with the “Procedure Manual for Design Projects Performed by Architects or Engineers” attached hereto as Exhibit A and any plans and specifications, instructions, general and/or standard terms and conditions, any addenda issued, and the "Request for Qualifications" documents, where applicable, on file with the PARISH which have been furnished to the ENGINEER, all of which are as much a part of this agreement as if repeated verbatim herein.

NOW THEREFORE, the PARISH and the ENGINEER do mutually agree to the following terms and conditions of this agreement:

1. Scope of Work

The PARISH hereby agrees to engage the ENGINEER to provide the services inclusive in the PARISH's "Request for Qualifications." This project involves providing professional engineering services related to various projects within the Capital Improvements Projects (CIP) Program, as needed. The ENGINEER will comply with the requirements denoted in the “Procedure Manual for Design Projects Performed by Architects or Engineers” attached hereto as Exhibit A. When applicable, the ENGINEER may subcontract portions of the services but each subcontractor must be approved in advance by the PARISH in writing.

The scope of the work may require the services of personnel identified in Exhibit B which will be the responsibility of the ENGINEER. These services will be billed as additional services in accordance with the “Procedure Manual for Design Projects Performed by Architects or Engineers” attached hereto as Exhibit A. No services shall be performed without specific, separate, written authorization, in the form of Task Orders, from the PARISH's Project Manager.

Any additional services not specifically listed in the “Request for Qualifications” but required by the PARISH and available to the ENGINEER may be added to the terms of this agreement at a mutually agreed upon price, subject to the verification of cost reasonableness of said change order. Any change order is subject to any grant limitations, if applicable.

With the implementation of Louisiana Revised Statute 38:2191 requiring the payment of reasonable attorney fees and interest for any public entity failing to make any progressive or final payments within forty-five (45) days following receipt of a certified request for payment, the ENGINEER is therefore required to submit the payment recommendation to the PARISH within fifteen (15) days of receipt of the same from the contractor. Absent reasonable cause as provided in state law, the ENGINEER will be responsible for attorney fee and interest payments if assessed.

The PARISH reserves the right by written amendment to make changes in requirements, amount of work, or engineering time schedule adjustments.

2. Term of Agreement

The initial term of this agreement shall commence upon execution of this agreement and shall continue until December 31, 2027. Upon completion of the initial term, this agreement shall automatically renew for two (2) consecutive one-year periods at the same prices, terms and conditions unless either party provides advance written notice of its intent not to renew.

The delivery schedule for all project deliverables will be established by the PARISH’s Project Manager. If any required time frame is not met then the ENGINEER will notify the PARISH as to the new expected completion date and the reason for the delay and obtain approval from the PARISH for the revised time period.

3. Payment Terms

Under this agreement, the PARISH agrees to pay the ENGINEER an hourly fee based on the hourly rate schedule, attached hereto as Exhibit B, not to exceed the maximum amount of one hundred fifty thousand dollars ($150,000), which is inclusive of all amounts properly due under the terms and conditions of this agreement. This maximum “not-to-exceed” amount is incrementally valid for the initial term of this agreement as well as for each of the renewal periods, and is inclusive of all costs associated with this project.

The ENGINEER will issue invoices with the supporting documentation reflecting the amount and value of work accomplished to date in accordance with Article 6 of the “Procedure Manual for Design Projects Performed by Architects or Engineers” attached hereto as Exhibit A. All hourly billing must be in sufficient detail to identify daily time by employee and description of additional services performed. When the ENGINEER is performing any service (i.e. surveying, etc.) that is billing on an hourly basis, no markup will be allowed for that particular service even in cases where a subcontractor is utilized to complete a portion of that service. General category references for services performed are not acceptable. Milestone dates established by the PARISH Project Manager must be met in order for the monthly payments to be processed. The PARISH will, in all good faith, attempt to review and process for payment the properly submitted invoice within thirty

(30) days.

If this agreement extends beyond the current fiscal year and notwithstanding anything to the contrary and when applicable, the ENGINEER acknowledges and agrees that pursuant to the applicable state law, this agreement is subject to an annual appropriation dependency requirement to the effect that the renewal of this agreement is contingent upon the appropriation of funds to fulfill the requirements of this agreement. If the PARISH fails to appropriate sufficient monies to provide for payments under this agreement, then this agreement shall terminate on the last day of the last fiscal year for which funds were appropriated.

4. Amendments and Assignments

If there is a need to review and/or revise this agreement, the requesting party shall submit a written amendment to the other party, with the understanding that no amendment to this agreement shall be valid unless it is agreed to and signed by both parties. This agreement shall not be assignable by either party without the written consent of the other, except for assignment resulting from the merger, consolidation, or reorganization of the assigning party.

5. Ownership or Reuse of Documents, Parish Provided Documents, Records and Audits

Ownership or Reuse of Documents Provision - All data collected by the ENGINEER and all documents, notes, drawings, tracings and files collected or prepared in connection with this work, except the ENGINEER’s personnel, administrative and proprietary information, shall become and be the property of the PARISH. The PARISH shall not be restricted in any way whatsoever in its use of such material, except as specifically provided in Louisiana Revised Statute 38:2317. All documents, including drawings and specifications furnished by the ENGINEER pursuant to this agreement, are intended for use on this project only. Reuse by the PARISH shall be subject to the applicable provisions of Louisiana Revised Statute 38:2317.

Parish Provided Documents Provision - The ENGINEER shall indicate to the PARISH the information needed for the rendering of services hereunder. The PARISH may elect to provide this information (including services by others) to the ENGINEER. In this case, the PARISH recognizes that the ENGINEER cannot assure the sufficiency of such information. Accordingly, the ENGINEER shall not be liable for any claims for injury or loss arising from errors, omissions or inaccuracies in documents or other information provided by the PARISH.

Records and Audits Provision - The ENGINEER shall maintain accounts and records, including personnel, property, and financial records, adequate to identify and account for all costs pertaining to this agreement and such other records as may be deemed necessary by the PARISH to assure proper accounting for all funds. For audit purposes, all records will be made available by both parties to any authorized representative of either party and said records will be retained for three (3) years from the final contractual payment under this agreement. It is also agreed that all records shall be made available to either party at no additional charge for such information. If any confidential information is obtained during the course of this agreement, both parties agree not to release that information without the approval of the other party unless instructed otherwise by court order, grantor, auditor, public information request or as required by law.

6. Liability (Contractual Relationship), Indemnity, Insurance and Hazardous

Materials

Liability (Contractual Relationship) - The ENGINEER shall perform its scope of services hereunder in accordance with all plans and specifications and the terms and conditions of the ENGINEER’s proposal as well as complying with all applicable laws and regulations.

All products and/or services will be provided or performed in a thorough and professional manner to the satisfaction of the PARISH.

This agreement is intended for the benefit of the PARISH and the ENGINEER and does not confer any rights upon any other third parties. All rights by and between the PARISH and the ENGINEER are limited to the actions outlined in the applicable local, state and federal laws, regulations and policies. The ENGINEER shall serve as the PARISH’s professional engineering consultant with respect to the aforementioned project and both parties agree that they have not entered into a joint venture or partnership and the ENGINEER is not considered the agent of the PARISH.

Indemnity Provision - The ENGINEER will indemnify and hold harmless the PARISH, including the PARISH’s employees and agents, from and against any and all claims or liabilities arising from the fault of the ENGINEER, its employees, subcontractors or agents in carrying out the ENGINEER’s duties and obligations under the terms of this agreement. The PARISH will indemnify and hold harmless the ENGINEER, including the ENGINEER’s employees and agents, from and against any and all claims or liabilities arising from the fault of the PARISH, its employees or agents in carrying out the PARISH’s duties and obligations under the terms of this agreement. This section will survive the termination of this agreement. In the event that either party takes any action to enforce this mutual indemnity provision, the prevailing party shall be entitled to recover reasonable attorney’s fees and costs arising as a result thereof.

The PARISH shall not be liable to the ENGINEER, and the ENGINEER shall not be liable to the PARISH, for any special, incidental or consequential damages, including, but not limited to, loss of use and loss of profit, incurred by either party due to the fault of the other, regardless of the nature of this fault, or whether it was committed by the PARISH or the ENGINEER or their employees, agents or subcontractors by reason of services rendered under this agreement.

Insurance and Licenses Provisions - The ENGINEER will comply with the insurance requirements as specified in Exhibit C. Evidence of compliance with the attached insurance requirements will be provided to the PARISH prior to the commencement of any work. The ENGINEER is also required to maintain all licenses as may be required by other regulatory agencies.

Hazardous Materials Provision - When hazardous materials are known, assumed or suspected to exist at a project site, the ENGINEER is required to take appropriate precautions to protect the health and safety of his personnel, to comply with the applicable laws and regulations and to follow procedures deemed prudent to minimize physical risks to employees and the public. The PARISH hereby warrants that, if it knows or has any reason to suspect that hazardous materials may exist at the project site, the PARISH will inform the ENGINEER in writing prior to initiation of services under this agreement.

Hazardous materials may exist at a site where there is no reason to believe they could or should be present. The PARISH agrees that the discovery of unanticipated hazardous materials could constitute a changed condition which may require a re-negotiation of the scope of work or termination of services. The ENGINEER agrees to notify the PARISH as soon as practically possible should unanticipated hazardous materials or suspected hazardous materials be encountered.

7. Independent Contractor Status

The ENGINEER shall provide the services contemplated under this agreement as an independent contractor and not as an employee, agent, joint venturer, subcontractor or partner of the PARISH. Nothing in this agreement shall be construed as creating any other relationship between the ENGINEER and the PARISH, or between any employee, agent, joint venturer, subcontractor or agent of the ENGINEER and the PARISH. During the term of this agreement, all persons employed by ENGINEER shall be employees of the ENGINEER for purposes of the ENGINEER’s benefit programs for plans now existing or hereafter created, workers’ compensation, compensation, and payment and withholding of federal, state and local income, social security, unemployment, Medicare, and other payroll taxes.

The ENGINEER acknowledges that he is an independent contractor within the meaning of Louisiana workers’ compensation law, specifically Louisiana Revised Statute 23:1021 (7).

The ENGINEER is rendering a service, other than manual labor, for a specified recompense for a specified result either as a unit or as a whole, under the control of the PARISH as to the result of his work only, and not as to the means by which such result is accomplished.

8. Warranties (Responsibilities), Termination or Suspension of Agreement and

Dispute Resolution and Legal Proceedings

Warranties (Responsibilities) Provision - The ENGINEER warrants the following: (a) that it has the experience and ability to perform the scope of work required in this agreement,

(b) that it will perform said scope of work in a professional, competent and timely manner,

(c) that its services, reports and materials furnished hereunder will be as represented, (d) that it has the power to enter into and perform this agreement, and (e) that its performance of this agreement shall not infringe upon or violate any third party’s rights or any federal, state or municipal law.

Termination and Suspension Provisions - While both parties agree to negotiate all contractual disputes in good faith, the PARISH reserves the right to terminate this agreement at any time upon written notice of termination, in which event, the ENGINEER will be reimbursed for all products and/or services satisfactorily provided and properly documented up until the date of termination. If the notice of termination states that it is “for cause”, the PARISH will state the cause or causes alleged and may withhold payment of any costs and fees related to, arising from or incidental to the stated cause or causes for termination.

This agreement may also be terminated by the ENGINEER upon thirty (30) days’ written notice in the event of substantial failure by the PARISH to perform in accordance with the terms hereof through no fault of the terminating party.

The ENGINEER is required by Louisiana Revised Statute 38:2216.1 to certify that it does not discriminate against any firearm entity or firearm trade association (see attached Exhibit D). The ENGINEER is also required by Louisiana Revised Statute 38:2224 to attest via affidavit that it did not employ or pay any person, corporation, firm, association or other organization to solicit this contract (see attached Exhibit E). No public contract may be granted to any person, corporation, firm, association or other organization refusing to execute the affidavit.

Legal Proceedings Provision - If the parties are unable to independently and satisfactorily resolve any disagreement then both parties agree that any contractual disagreement will be resolved under the jurisdiction of the 14th Judicial District Court for Calcasieu Parish, Louisiana. In addition, if it is necessary to enforce this agreement in any judicial forum, then the parties agree that whoever prevails in the litigation shall be entitled to reasonable attorney fees and costs as fixed by the Court.

9. Severability, Entire Agreement and Captions

Severability Provision - This agreement shall be governed by and construed in accordance with the laws of the State of Louisiana. If any provision of this agreement is held invalid, void or unenforceable under any law or regulation or by a court of competent jurisdiction, such provision will be deemed amended in a manner which renders it valid, or if it cannot be so amended, it will be deemed to be deleted. Such amendment or deletion will not affect the validity of any other provision of this agreement.

Entire Agreement Provision - This agreement, any attached documents, and any referenced documents, represent the entire agreement between the PARISH and the ENGINEER and supersede all prior negotiations, representations or agreements, either written or oral. In the event of a conflict between this agreement and other documents, the terms of this agreement shall control.

Captions Provision - Each paragraph of this agreement has been supplied with a caption to serve only as a guide to the contents. The caption does not control the meaning of any paragraph or in any way determine its interpretation.

10. No Authorship Presumptions

The PARISH and the ENGINEER have had an opportunity to negotiate the language of this agreement in consultation with legal counsel prior to its execution. No presumption shall arise or adverse inference be drawn by virtue of authorship. The PARISH and the ENGINEER hereby waive the benefit of any rule of law that might otherwise be applicable in connection with the interpretation of this agreement, including but not limited to, any rule of law to the effect that any provision of this agreement shall be interpreted or construed against the party who (or whose counsel) drafted that provision.

The rule of no authorship presumption set forth in this paragraph is equally applicable to any person that becomes a party by reason of assignment and/or assumption of this agreement and any successor to a signatory party.

11. Designation of Authorized Representatives and Notice Addresses for Communications

All notices between the PARISH and the CONTRACTOR provided for pursuant to this agreement shall be in writing. The name and address of the PARISH's representative is:

Mr. Dane R. Bolin, Administrator

P.O. Box 1583 Lake Charles, Louisiana 70602

The name and address of the ENGINEER's primary representative is:

In the event…