C04a LSS Cubicle SOW Electrical_12444326Q0074.pdf
PDF 9 MB Posted
- Solicitation number
- 12444326Q0074
- Issued by
-
Department of Agriculture Forest Service
About this file
This is a Statement of Work (SOW) for the procurement and professional electrical installation of office cubicles at the USDA's Cereal Crops Research Unit in Madison, Wisconsin.
The project requires installation of five 5' x 7' corner desks with adjustable height on one side and one 4' hoteling adjustable height desk in an office space measuring 19'7" long by 15'2" wide. Each station must include two duplex electrical outlets and two RJ45 data ports integrated into the cubicle spine or panel. The contractor is responsible for providing all labor, materials, supplies, tools, equipment, and transportation necessary for professional installation adhering to federal, state, and local safety regulations. A licensed electrician provided by the contractor must hardwire the cubicles into existing electrical outlets, with wires routed through spine or corner sections. The contractor shall remove all packaging materials and debris, leaving the site clean and ready for use. Work must be performed during normal business hours (Monday-Friday, 7:00 AM - 5:00 PM) with coordination through the Government Point of Contact. The contractor is responsible for maintaining liability and workers' compensation insurance, ensuring personnel are qualified and legally authorized to work in the United States, and adhering to all facility security protocols and background check requirements. Acceptance is based on work meeting industry-accepted quality standards and all SOW specifications, with any identified deficiencies to be corrected at no additional cost. The Government will provide workplace access, designate a POC for coordination, and facilitate background checks as required.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| C04 Solicitation COMPLETE_12444326Q0074.pdf | ||
| C04b SAM Wage Determination 2015-4897_12444326Q0074.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK (SOW)
FOR Location Support Staff Cubicles
1.0 PROJECT OVERVIEW This Statement of Work (SOW) defines the requirements for the procurement and professional electrical installation of a 5-station cubicle and one single hotel desk arrangement. This would include the electrical connection required to hardwire the new cubicles into the existing wall outlets. The purpose of this project is to create a functional, efficient, and aesthetically pleasing workspace within Cereal Crops Research Unit located at 502 Walnut Street Madison, WI. This SOW outlines the scope of work, deliverables, responsibilities, and acceptance criteria for the selected contractor.
2.0 BACKGROUND The Location Support Staff require new cubicles to accommodate five (5) employees and (1) hoteling location in an open office environment. The new workstations are intended to provide dedicated, semi-private workspaces that support productivity and collaboration while maximizing the efficient use of available office space.
3.0 SCOPE OF WORK The Contractor shall provide all necessary labor, supervision, materials, supplies, tools, equipment, and transportation required to perform the installation as described herein. All work shall be performed in a professional, safe, and environmentally responsible manner, adhering to all applicable federal, state, and local regulations.
3.1 General Requirements Applicable:
• Power and Data Integration: Integrate power and data raceways/channels within the cubicle system, ready for connection by Agency IT/Facilities personnel.
• Site Cleanup: Remove all packaging materials, debris, and waste generated during the installation process, leaving the site clean and ready for use.
4. DELIVERABLES Upon successful completion of the project, the Contractor shall deliver the following:
• Five (5) complete and (1) hoteling fully installed cubicle workstations, each meeting the specifications detailed in Section 5. All cubicles will be hardwired by licensed electrician provided by the vendor into existing electrical, and wires will run through spine or corner sections of cubicles by installers.
• Waste removal and site cleanup, leaving the installation area free of debris.
• Project completion documentation, including a signed acceptance form.
5.0 REQUIREMENTS AND SPECIFICATIONS The office space is 19’7” long by 15’2” wide. Install (5x) 5’x7’ corner desks with one side adjustable height and Install (1x) 4’ hoteling adjustable height desk.
5.1. Components per Station:
• Power/Data:
• Two (2) Duplex Electrical Outlets per station, integrated into the cubicle spine or panel.
• Two (2) Data Ports (RJ45) per station, integrated into the cubicle spine or panel (Contractor to provide raceway/faceplates; Agency IT to run and connect data cables).
6.0 GOVERNMENT RESPONSIBILITIES The Government shall:
• Provide access to the workplace during normal business hours (e.g., Monday-Friday, 7:00
AM - 5:00 PM).
• Designate a Government Point of Contact (POC) for coordination and oversight.
• Facilitate background checks for Contractor employees as required.
7.0 CONTRACTOR RESPONSIBILITIES The Contractor shall:
• Provide all necessary labor, supervision, materials, supplies, tools, and equipment.
• Adhere to all federal, state, and local safety regulations, including OSHA standards.
• Coordinate all work activities and schedules with the Government POC.
• Maintain appropriate liability and workers' compensation insurance.
• Ensure all personnel are qualified and, if required, undergo necessary background checks.
• Comply with all environmental regulations regarding chemical applications and waste disposal.
8.0 LOCATION
The work will be performed at:
Cereal Crops Research Facility 502 Walnut Street Madison WI, 53726
9.0 ACCEPTANCE CRITERIA The Government POC will conduct periodic inspections to ensure compliance with the SOW requirements. Work shall be performed to industry-accepted standards of quality and aesthetics. Any deficiencies identified by the Government POC shall be corrected by the Contractor within a mutually agreed-upon timeframe at no additional cost.
Services will be accepted upon satisfactory completion of all tasks as verified by the Government POC. Acceptance will be based on the work being performed to a professional standard, meeting all specifications outlined in this SOW, and achieving the desired aesthetic and functional outcomes.
10.0 SECURITY REQUIREMENTS Contractor personnel shall adhere to all facility security protocols, background checks, sign-in/sign-out procedures, and access restrictions as directed by the Government POC. All personnel working on-site must be legally authorized to work in the United States.
11.0 POINT OF CONTACT Mark Cumming mark@cumming@usda.gov and Brittney Jones brittney.jones@usda.gov mailto:mark@cumming@usda.gov mailto:brittney.jones@usda.gov
15'-2"
D
I -!
I
I I -!
I
I I
I ·- I .
Hon®
PROJECT INFO
REQ-00311601.cmdrw
HENRICKSEN & COMPANY
INC - PEORIA
USDA ARS Wisconsin
DESIGNER:
PRANAY REDDY TALLA
EMAIL:
ReddyPr@hni-asia.com
DATE:
1/19/2026
NOTE: The customer is ultimately responsible for the accuracy and correctness of component counts and measurements.
The customer is also responsible for the space planning and all design work of projects. Customer shall verify and confirm all site conditions, dimensions, and suitability of products and applications consistent with published guidelines and applicable codes.
Liability of The HON Company shall be limited to the amount charged for the Specification Services rendered and in no event shall The HON Company be responsible for any consequential or incidental damages.
SCALE: NTS 3/5
Accelerate” features capabilities for cable management, including electrical, voice, and data. The 8-wire electrical system can be integrated at base pathway.
See Systems electrical pages 559-565 for electrical models to be used with Accelerate” Systems products. See page 384 for Abound“ frame horizontal and vertical wire capacity and page 549 for base pathway capacity.
Effective August 23, 2025, HON will WORKSTATIONS 2026 Workspaces Pricer HOn 543 apply a 3% surcharge to all orders.
Integrated accommodates in-i‘eed and communication/data
Power
l. é
Pole power lines
/_é ,""--Il--Ii
Ceiling in-feed connects to building electrical supply.
O
O mu!
.7
IIIIQ
7/ ilmnml“ll5:.‘i l
1m l
\3
\‘ i
Electrical power harness accepts Fiber optic cables to 2 duplex can follow 90°up turns at thereceptacles per Base pathway power in-feed
Base pathway Power into base blocks pathway snap panel side (24uW panel intersection runs.
of mounts into any receptacle accommodates horizontal frame limited to 1) at position in the base pathway power and lay-in members and base pathway. area and is connected to the capacity for data and accept duplex building electrical supply.
communication. receptacles.
THE ACCELERATE
ELECTRICAL SYSTEMS
Accelerate offers a choice of three electrical systems:
- Four-circuit, 3 +1
- Four~circuit, 2 + 2
° Three-circuit, separate neutrals
All three systems utilize an 8-wire electrical system, rated at 20 amps per circuit (15 amps Canadian). See pages 546-547 for a detailed explanation of each electrical system.
Accelerate panels and electrical components are UL Listed.
Electrical components are also CSA certified.
installation and use of the electrical system, the number of receptacles used on a given circuit and connections to the building power supply should be in compliance with all local and national electrical codes.
Caution: Electrical equipment cords or extension cords MUST NOT BE ROUTED through cable openings in frame sides.
Accelerate's electrical harnesses are UL listed and are considered raceways themselves as defined by the National Electrical Code. This means there is no separation requirement between the electrical harnesses and communications cables per Sec. 800-52 of the National Electrical Code.
Communication cables may be placed next to Accelerate's electrical components without a metal septum and will still meet the guidelines ofthe Telecommunications Industry Association for separation of power and data.
lN-FEEDS
Power in-feed cables deliver power from building to system.
ln—feed cables are housed in conduit to separate electrical system from communications and data lines.
integrated PowerPole accommodates power in-feed and communication/data lines
Ceiling in-feed connects to building electrical supply.
Sealtight base pathway power in-feed attaches to a receptacle opening at the base pathway. A heavy rubber sheathing shields conduit, allowing in—feed to be exposed.
Integrated power and communications poles provide capacity for routing power supply directly through the top of any connector. When using a ceiling power in-feed, consider that the in-feed must connect into an electrical harness located in an adjacent panel. (See pages 548~ 549 for cable capacity.)
Ceiling power in-feed connects to a prewired electrical harness in the beltline or base pathway, traverses through an adjacent panel and terminates in thejunction box at the top of the integrated power pole. For use with integrated power pole models HECPP. No portion of the flex cable can be exposed after installation.
WORKSTATIONS
Hardwire (New York Code) power in-feed (model H87l400) is used when local electrical codes require hardwire entry. When used in 24"W, 30"W and 36"W panels, power can be routed only in one direction. When used in 42", 48"W and 60"W panels, an electrical pass—thru cable or harness for that panel width can be used to route power back in the opposite direction. Unit must connect to a power or pass-thru harness positioned in the base pathway area of an adjacent panel. Customer to furnish all cabling and wiring from power entry to power source.
Junction box can be positioned at any duplex receptacle location.
544 HOn 2026 Workspaces Pricer
HARDWIRE (CHICAGO CODE)
JUNCTION BOX
Wiring harnesses and snap connectors are not allowed in Chicago -— base pathways must be comprised of all metallic components. Concealed mounting is the only option at beltline. For the base pathway, junction box (model HH871500) clips directly into receptacle locations. Customer must furnish conduit, wiring, standard duplex receptacles with metal covers for the beltline and designer—type receptacles for the base pathway. Power entry can be routed from the ceiling, via an Accelerate power pole, or from the floor into a junction box (model HH871500). See Systems electrical pages 559-565 for electrical models to be used with Accelerate” Systems products.
DUPLEX
RECEPTACLES
For Duplex Receptacle models that can be used on Accelerate" panel systems, please see page 562.
All Systems electrical components can be found on pages 559~565.
Wu” l mmwu—m
Effective August 23, 2025, HON will apply a 3% surcharge to all orders.
WORKSTATIONS
ACCELERATE®
Electrical and Data
LIGHTING
Task lights can be recessed under storage cabinets or storage shelves‘
Task lights in four sizes are available to correspond to cabinet or shelf width. They have 9’ power cords in black. connected in the right rear corner. Ail models feature
LED light strip for improved light quality. Task lights with a fused plug to meet Chicago electrical code are also available.
Recommendation: Provide a separate circuit for task lights for proper long-term operation without RF interference to computers that may be in use.
LED TASK LIGHTS
No finish specification required.
Attaches magnetically to underside of overhead storage, or attaches with provided screws.
Occupancy sensor attaches to a single or starter LED light and will automatically turn the light off after no motion is detected for 30 minutes.
Just like all the LED light models.
the occupancy sensor features a soft-touch on/off switch. LED task lights have a lifetime of 50,000 hours and have a dimmer feature that allows the user to adjust the amount of light output.
Daisy chain options are available.
To use the daisy chain application.
must start with model HLEDI7A or HLED3lA.
Effective August 23, 2025, HON will apply a 3% surcharge to all orders.
VOICE/DATA
RECEPTACLES
Abound not only provides space for large volumes of voice and data cables, it also offers several means of mounting commercially available voice and data components.
Commercially available modular data faceplates can be mounted in vacant base receptacle openings or can be mounted in data/electrical port tiles above or below the worksurface.
WORKSTATIONS
Cable management troughs attach to worksurfaces with provided screws. The graphite metal troughs are designed with cord access cut outs. These cut outs give users access to inside the trough without having to detach it from the worksurface.
uvmuaummww i
2026Workspacespricer HOI‘l 545
SNOIlVlSMEOM
To Order:
1. Determine which electrica! system you wiH use after consulting your electmcian and computer support personnek
- The Four-circuitsystem
(4-Hot/2-Neutral/2-Ground)
- 3 +1option
— 2 + 2 option
The Three-circuit system
(3-Hot/3-Neutral/Z-Ground)
. Determine location, quantity and circuit of duplexes.
. Determine the appropriate choice and use of isolated, Isolated/Dedicated and Separate Neutral circuits.
. Specify appropriate Power Harnesses‘ and Pass—
Thru Cables.*
. Determine the location, quantity and type of Power ln-feed needed.
Select Power Harness models (HH8712XX) and Pass~
Thru Cables (HH87HXX) wrth the last two digits beinq
1” (or 2") smaHer than the assoctate panel width, Electrical System Options The four—circuit, eight-wire electrical system is widety specified and trusted by hundreds of thousands ofend-users, This proven system delivers four circuits for every power in—feed in either a 3 + l or 2 + 2 configuration. The isolated/dedicated circuits are ideal forsensitive computing equipment, while the common circuits are suitable for faxes, copiers, task lights and other peripherals.
Both the 3 + i and 2 + 2 systems use the same pre—wired components, making it easy to adjust as electrical needs change.
You can also choose a three-circuit, eight~wire system that has a dedicated neutral for every hot circuit. The three—circuit components have model numbers with an
”A” suffix and appear in a gray box in this pncer.
DUPLEX RECEPTACLE
D
GRAy E NEUTRAL-2
WHn-E E neuTHAL - i
GRN/YLW E GROUND
ISOLATED
The 3 + 1 optiOh is the electrical standard used by The HON Company for many years in most of their systems products. This wiring option provides three utility circuits plus an isolated/dedicated circuit for more sensitive equipment.
CIRCUIT4
ISOMTED/
CIHCUIT2 CIRCUITS DEDICATED
I £Q
CIRCUIT 1
IOGA
106A
12GA
126A
12GA
12GA
12GA
12GA
GREEN E GROUND
PINK a Hm» BLUE E Her a RED E How
BLACK E HOT-1
The 2 + 2 option is a wiring option that provides two utility circuits and two isolated circuits for more extensive computer usage applications.
DU PLEX RECEPTACLE
D = a
GRAY E NEUTRAL-2
WHnE E NEUTRAL—i
GHNNLW 'éé‘aGTNEDD
CIRCUITG CIRCUIT4
CIRCUITT CIRCUIT2 ISOLATED ISOLATED
do 10GA
10GA
126A
12GA
i2GA
12GA
12GA
12GA
GREEN a eHouND
PINK E Hot-4 BLUE E Hon
RED E HOTV
BLACK E Ho‘r -ruAm
546 2026 Workspaces Pricer Effective August 23, 2025, HON will apply a 3% surcharge to ail orders.
Four-circuit, 3 + 1 Receptacle Option
Four-circuit, 2 + 2 Receptacle Option
WORKSTATIONS
Hot Wire
Hot Wire
Hot Wire
Neutral 1
Common
Utility Crompute
Hot Wire
Neutral 3
Common Ground isolated Ground
DUPLEX RECEPTACLE
CIHCUIT 1
F
Three-circuit, separate neutrals
CIRCUIT 3
ISOLATED]
CIRCUIT 2 DEDICATED
12 GA
12 GA
12 GA
12 GA
12 GA
12 GA
_ 12GA
m 4:9
Notes:
- Four-circuit components and three-circuit components (with suffix "A”) cannot be used together.
Components of the two systems are keyed differently to prevent components of one system from being connected to components of another System.
HON Cat. Nos. are printed on the UL labels, and components are color-coded to provide visual identification of the different components.
Four—circuit components have black plastic parts.
Three-circuit components have rust-colored terminal ends and receptacle backs are rust colored.
(1) Circuit-2 (one ofthe 3 common circuits sharing a neutral wire) cannot be used with a single-phase building electrical supply.
Typical power usage by the most commonly specified office equipment.
Source: Industly Analysis, /nc., Rochester, NY
EQUIPMENT AMPS
Computers Personal Computer Notebook Computer
Monitors 13” Color Monitor 17" Color Monitor 21" Color Monitor
EGUIPMENT AMPS
Copiers Desktop Copier Console Copier Copier/Duplicator ................... 3O
Printers Dot Matrix ................... less than1 InkJet ....................... less than1 Personal Laser or LED Workgroup Laser or LED
EQUIPMENT AMPS
FAX Machlnes lnkJet FAX ................... less than1 Thermal FAX ................. less thani Plain paper FAX
Task Lights 36" T8 Fluorescent ............ 0.2/bulb 48" T8 Fluorescent ............ O.3/bulb
Duplex Receptacles
15 AMP Receptacle
20 AMP Receptacle (Required by some large copiers.)
Effective August 23, 2025, HON will apply a 3% surcharge to all orders.
WORKSTATIONS 2026Workspacespricer HOn 547
SNOIlVlSMEOM The Three-circuit, separate neutrals configuration is a wiring option that provides separate neutrals for each of the three circuits. Two circuits share a common ground, and one circuit is isolated/dedicated. The three-circuit components have model numbers with an
“A" suffix and appear in a gray box in this pricer.
mar yHa.
1.
WI!-
mmwu-m-m a
.mmnm.
um” m..
SYSTEMS
ELECTRICAL SPECIFYING INFORMATION
Two 8-wlre, 20 AMP (15 AMPCanadian) electrlcal systems are offered
Electrical System Circuitry Receptacle Capacity
Four-clrcult 4-Hot/2-Neutral/2-Ground
(10 gauge neutral wires)
3 + 1 Common Circuit-1
HH873501
Common Circuit—2 (1)
HH873502
Common Circuit-3
HH873503
Isa/Dedicated Circuit-4
HH873504
Common Common Isolated Isolated 2 + 2 Circuit~1 Circuit-2 Circuit-3 Circuit-4
HH873501 HH873502 HH873506 HH873504
Three-clrcult 3-Hot/3-Neutral/2-Ground
(12 gauge neutral wires)
W/SePa'ate "9“"3'5
Common Circuit-1
HH873501A
Common Circuit-2
HH373502A
ISO/Dedicated Circuit-3
HH873503A
N/A
“T” Connection “X" or Cross Connection
When endingpowerin two return pane/s, wiring pigtails must be returned to original panel run.
548 HOn 2026 Workspaces Pricer
' Abound and Accelerate panels are UL listed.
CSA Certified.
It is the customer’s responsibility to ensure that use of the pre-wired electrical system, the number of receptacles used on a given circuit. and connection to a building power source, be in compliance with all local and national electrical codes.
- Contact Customer Service for additional information.
Electrical components are UL Listed and - Pedestals and Laterai Fiies, positioned under worksurfaces. may render some receptacies inaccessible, and may prohibit use of grommets.
Deflnltion of components:
Electrical Power Harness
ElectricalPowerHarness Mode/ HH87I242 for4 ”WPane/s
- Used to distribute power in panels.
- Power distribution in eitherdirection.
r Specify Power Harness to match panel width.
- Double~sided: receptacles can be inserted into both sides of Power Blocks.
0 Three-way panel connections require at least one power harness.
0 4-way panel connections require at least two power harnesses.
Electrical Pass-Thru Cables
Pass- Thru Cab/e
Mode/HH877742 for4 ”WPane/s
Pass-Thru Cable With Duplex Capacity:
- Use in panels where multiple receptacles are not required.
- Added feature: has capacity for one receptacle on each side ofa panel.
Feature offers future expansion and is an alternative to Power Harnesses.
Various Electrical Layouts
Straight Line 90 Degree Corner tOne harness required
To power a 4-waypane/ connect/on from one direction, specify at ieast two doub/e block harnesses.
WORKSTATIONS
' Four—circuit components and Three- o Three-way panel connections require circuit components (with suffix “A") at least one power harness.
cam“ be used together' see pages
0 4-way panel connections require at 546-547. least two power harnesses.
0 A licensed electrician must make connections to a building electrical supply.
Duplex Receptacles i5 amp outlet configuration.
Models HH871601 and HH871601A have a 20 amp outlet configuration.
Fit back-to-back into the Power Block(s) of Power and Pass-Thru Harnesses.
Labeled with the provided circuit. Circuits connected to the Isolated Ground are identified with an orange triangle; circuits that do not share a neutral or ground have an orange circuit number.
Power ln-Feed (Base) Models HH879072 (72”) and HH879168 (168”) Used to connect the panel electrical system to the building electrical supply at a power block.
Plugs into any receptacle position; can be rotated Left or Right.
Conduit is UL listed Black Liquid-tight conduit (outside diameter is 7/a”).
9 A licensed electrician must make connections to a building electrical supply.
0 Must be positioned through a receptacle opening in the baserail cover, prior to an electrician connecting to the power source.
Power ln-Feed Model (Ceiling) HH871912 and HH8719‘I8
- Used to connect the panel electrical system to the building electrical supply.
0 A licensed electrician must make connections to a building electrical supply.
0 Model uses UL recognized flex-cable conduit —- no portion can be left exposed (i.e., must be in a power pole).
o Power Pole must be ordered separately.
HH877972
Note: ln-feed cables listed above may be field-cut to desired length.
Electrical Jumper Cables
0 When used to connect power between the base pathway and the beltline area, the jumper must be connected to a power block at one end ofa run, routed into an adjacent panel that does not contain a power harness, then routed back into the panel containing a power harness or pass-thru cable and connected to a power harness in the other pathway. HH877355
Abound Electrical Mounting Brackets ' Use to mount ported receptacles at beltline.
- Screw into the panel frame.
o One mounting bracket required at beltline for each 24”W pass—thru or power harness. Two required for 30"-60"W power harness.
HH8988EBN
Effective August 23, 2025, HON will apply a 3% surcharge to all orders.
i.
twp l.
mm m mmmwnmwmms
WORKSTAT
NS
SYSTEMS
ELECTRICAL SPECIFYING INFORMAT ON
Base Pathway Receptacle Locations
,—1o%"—‘ r—mS/au-j l——- 24" —--—-—-J r— 10%"—l ,—— 1o%”——l
30" l—- 105/8"—-j ,—1o%"——, i m a I l
36" I
'— 105/8"-—l f 105/3'I—' i a a I I 42" I r— 1ow—, r— 10%H—I i a m I I 48" I
[—— 105/a"——l r— 10%" ——1
I a D
Circuit Usage
Strategy1 C/rcu/ts to Equ/pment
Assign specific uses foreach ofthe circuits:
' For example, in a four—circuit system:
Circuit 7 — CaICUIators, fans, etcf
CircuitZ — Task lights (could be wired to wall switch)
Circuit3— Computer monitors
CircuiM — CPUs
Strategy 2 Circuits to Workstations
Assign specific workstations to each of the three available circuits, Use circuit 4 for power-sensitive electronic equipment.
i 60"
Placement of pedestals and Iateral files may render some duple>< Iocations inaccessible, Pedestal placement may also affect compatibility with pull—up receptacies
Abound“) Lay-in Cable CapacityAbound" Lay-in Cable Capacity
The top and base pathway allow continuous voice and data lines to run through and between panels without interruption. Lay-in is provided for environments where systems furniture or cabling are subject to frequent change. All capacities are for Cat 6 cable with a 0.25” diameter.
Aboundt Cable Capacity
End View 8 cables
Top pathway accepts up to 8 voice/data cables (.25" dia.).
Top View
3 cables
Variable heightiunctions accept up to 3 voice/data cables (.25” dia.).
Accelerate® Cable Capacity
Abound“ base pathway accepts up to 56 voice/data cables
(.25" dia.) (6.03 sqi in) at 60% fill.
When electrical system shares base pathway, the cable capacity in Abound is reduced to 16 cables
(2.25 sq. in). Cable quantities listed are at 60% fill ratio
66 cables with power
Cable capacity ofthe power pole, in addition to electrical in—feed is 2.79 sq. in. on one side and 2.9i sq. in.
on the other for a total capacity of 66 cables with power of .25” diameter.
25 cables with power
Integrated Power Pole: 2" x 2" overall, 3.3”2 interior accommodates a total of25 cables with powerof .25” diameter. Available in two heights: 6’6” or 13’, the power pole connects via the universal connector and the overall height is the sum of the connector and the power pole.
Constructed of aluminum with a powder coat paint finish in the specified color. Power pole requires a Ceiling In-Feed.
WORKSTATIONSEffective August 23, 2025, HON will apply a 3% surcharge to all orders.
Ceiling In-Feeds: UL listed as raceways.
This means the electrical components are completely shielded and meet any requirements for separation of electrical components and communications cables per Section
800-52 ofthe National
Electrical Code.
2026 Workspaces Pricer 549
56 cables 16 cables 12 cables
When the electrical system shares the base pathway, the cable capacity in Accelerate‘ is reduced to 12 cables (.25" dia.) (2.03 sq. in.)
at 60% fill ratio.
MODEL
MAX.RECEPT. FOUR-CIRCUIT THREE-CIRCUIT,
CAP. PER 3 + 1 SEPARATE SHIP LIST
DESCRIPTION PANEL SIDE 2 + 2 NEUTRALS WEIGHT CUBE PRICE
SONIlVSlMHOM m
HH871048 HHam4sA 3.0 0.5 $182 HHsmso HHsmsoA 3.0 0.5 $182
HH871072 4.0 0.5 $252
For 48”W Frames
For 60"W Frames
For 72"W Frame Runs murmu-~
NOTES:
- Duplex receptacles on page 562.
r Electric harnesses are intended for use with HON Systems furniture.
0 Four-circuit components and three~circuit components (with "A" suffix) not designed to be used together. See pages 546-547.
HOWTO SPECIFY
Select Select Model Number Color
See page 411
Elm-E Effective August 23, 2025, HON will w0RKsTA110N5 2026 Workspaces Pricer HOI'I, 559 apply a 3% surcharge to all orders.
SYSTEMS
@6 Electrical ComponentsIcon Legend on page 19
Electrical Power Harnesses, Frames — w/duplex capacity For 24”W 1 HH871224Q HH871224A 2.0 0.5 $301 For 30”W 2 HH871230 @ HH871230A 2.0 0.5 $301 For 36”W 2 HHsmzs 0 HH871235A 2.5 0.5 $301 For 42"W 2 1111871242 6 HH871242A 3.0 0.5 $317 For 48”W 2 mama© HH371248A 3.0 0.5 $317 For 60"W 2 HusmsoQ HHamsoA 3.0 0.5 $317 For 72"W (for use with Accelerate” 2 HH871272 HH871272A 5.0 0.5 $317 72”W panels only)
NOTES: When 36”W, 42"W, 48"W. or 60”W are purchased separately without a configurable TAA compliant end product, not on GSA contract.
Electrical Pass-Thru Cables, Frames — w/duplex capacity For 24"W 1 HHan124© HH871124A 2.0 0.5 $192 For 30"W 1 HH871130@ HH871130A 2.0 0.5 $192 For 36"W 1 1111371136 6 HH871136A 2.0 0.5 $192 For 42"W 1 1111371142© HH871142A 2.5 0.5 $201 For 48"W 1 1111371148© HH87II48A 2.5 0.5 $201 For 60"W 1 1111871160© HH871160A 3.0 0.5 $201 For 72”W (for use with Accelerate“ 1 HH871172 HH87II72A 5.0 0.5 $201 72”W panels only)
NOTES: For use when data will be terminated in one cutout in the panel. When 24"W-60”W are purchased separately without a configurable TAA compliant end product. not on GSA contract.
Electrlcal Pass-Thru Harness without Power Block For 24"W Frames O HH871024 HH87IO24A 2.0 0.5 $176 For 30"W Frames O HH871030 HH871030A 2.0 0.5 $176 For 36"W Frames 0 HH871036 HH871036A 2.0 0.5 $176 For 42”W Frames O HH871042 HH871042A 3.0 0.5 $182
NOTES: When purchased separately without a configurable TAA compliant end product. not on GSA contract.
Power ln-Feed Cables - Base In-Feed 72” long conduit, Sealtlght Cable — 7/a” diameter HH879072 @ HHs79o72A 4.5 0.3 $336 168” long conduit, Sealtlght Cable — 7/3” diameter HH879168 HH879168A 9,0 0‘4 $777
Use when local codes require
NOTES:
- Duplex receptacles on page 562.
0 Four-circuit components and three-circuit components (with “A" suffix) not designed to be used together. See pages 546-547.
Q To connect power between the base pathway and the beltline area on Abound, four-circuit jumper cables (H8713xx) must be connected to a power block at one end of a run, routed into an adjacent panel that contains no power harness, then routed back into the panel that contains a power harness (or pass~thru cable), and connected to a power harness in the other pathway.
Celllng ln-Feed
144” long conduit, Flex Cable ~ 7/3” dia. HH871912© HH871912A 4.0 0.5 $349 216” long conduit, Flex Cable —- 7/s"dia. HH871918 HH871918A 4.0 0.5 $453
0 Must be used with Power Pole. Power in-feed models HH871912 and HH87l9l8 plug into the end of any power block. No portion of the cable can be exposed after installation.
Hardwire Applications
Hardwire Power ln-feed HH871400 Q HH871400A 4.0 0.3 $328 o Customer to furnish all cabling and wiring from power entry to power source (approved for use by city of New York).
Hardwire Junction Box (6-pack) HH873500 4.5 0.2 $648
0 For use with Abound” Raceway panels only.
NOTES: Junction Box can be positioned at any Duplex Receptacle location in 30”W or wider panels.
9 Contact Tailored Solutions for back-to-back Junction Box standard special number.
Select Model Number
Select Color
See page 411 m-D
560 Hon 2026 Workspacespricer WORKSTATIONs Effective August 23, 2025, HON will apply a 3% surcharge to all orders.
miniumm-"rm
HOWTO SPECIFY
@6 Icon Legend on page 19
MODEL
FOUR-CIRCUIT THREE-CIRCUIT,
3 + 1 SEPARATE SHIP LIST
DESCRIPTION 2 + 2 NEUTRALS WEIGHT CUBE PRICE
Electrical Jumper Cables Jumper for up to 36" verticaljump, 66" long HH871366 HH871366A 3.0 0.5
- Used for routing ln-Feed Cable from ceiling to panel baserail. Double cavity, plus conduit of ln-Feed Cable serves as the division of electrical and communications cabling.
DESCRIPTION
Receptacle Cover Replacements
Quantity 25
0 For use with Accelerate” panels only.
0 Specify Color —- Available in Black (P) and Muslin (T3) only.
MODEL SHIPWEIGHT CUBE LISTPRICE
HERECPCVR 1 9 0.1 $110
DESCRIPTION
LIST PRICE BY PAINT GRADE
CUBE P1 P2 P3
SHIP
MODEL WEIGHT
w-mmmnmwm~
Icon Legend on page 19
SYSTEMS
Electrical Components
SNOIlVSlMHOM
SHIP LIST PRICE BY PAINT GRADE
DESCRIPTION MODEL WEIGHT CUBE P1
Abound” Integrated Power Pole For 35"H-50"H Frames. Poles are 78"H. HEP35 9 D 0.6 $558 For 65"H-95"H Frames. Poles are 52”H. HEP65 6 G 0.4 $396
NOTES: Power Pole includes ceiling trim piece.
FLAT CHAMFERED SHIP LIST PRICE BY PAINT GRADE
DESCRIPTION MODEL MODEL WEIGHT CUBE P1
Power Pole Trim Kit (Abound" only)
24”W HRVP24PF HRVP24P 2 6 0.3 $200
30"W HRVPSOPF HRVP30P 3 6 0.4 $210
é 36”W HRVP36PF HRVP36P 4O 0.5 $221
42"W HRVP42PF HRVP42P 59 0.5 $225
48"W HRVP48PF HRVP48P 6 O 0.6 $231
60"W HRVPGOPF HRVP60P 7G 0.7 $246
DESCRIPTION MODEL SHIP WEIGHT CUBE LIST PRICE
Power Pole — w/o Receptacles (Voi‘ only)
10,5” HH870070 14 0.5
Specifypaint color for HH870070, notavai/ab/e in Putty
SHIP LIST PRICE BY PAINT GRADE
DESCRIPTION MODEL WEIGHT CUBE P1 P2 P3
Accelerate” Integrated Power Pole 78”H x 2"W x 2"D HECPP© 14 9 0.5 $403 $427 $429 156”H x 2”W x 2"D
NOTES: Connector posts where power pole will
HECPP156
enter need to be specified
28 1.0 with single connector straps, $971 $995 $997 model HECSI.
Replacement Covers for Abound’ Panels HRECPCVRz 0.1 $60 $66 $69 HRECPcvmz 0.1 $175 $193 $201
HOWTO SPECIFY
Select Select Model Number Paint Color
See page 411
Effective August 23, 2025, HON will wonKsTA'nons 2026 Workspaces Pricer HOn 561 apply a 3% surcharge to all orders.
MODEL
FOUR-CIRCUIT THREE-CIRCUIT,
3 + 1 SEPARATE SHIP LIST
DESCRIPTION 2 + 2 NEUTRALS WEIGHT CUBE PRICE
Abound“ Duplex Receptacles Circuit 1 HH873501 HH873501A 0.5 0.1 $65 Circuit 2 HH873502 HH873502A 0.5 0.1 $65Each marked with Circuit 3 HH873503 HH873503A 0.5 0.1 $65Circuit Number Circuit 4 — isolated, dedicated circuit HH873504 0.5 0.1 $65
Circuit1 — 20 amp outlet HH871501 HH871601A 1.0 0.1 $65 Circuit 3 (2 + 2) HH873506 0.5 0.1 $65
Specify color.
a Duplex receptacle models above are for use with Abound‘ models only.
MODEL
FOUR-CIRCUIT THREE-CIRCUIT, CORE
3 + 1 SEPARATE SHIP LIST
DESCRIPTION 2 + 2 NEUTRALS WEIGHT CUBE PRICE
Accelerate‘ Duplex Receptacles
Circuit1 HHsnsoI © HH871501A 1.0 0.5 $65 Circuit 2 HH871502 @ HH871502A 1.0 0.5 $65
Each marked with Circuit 3 (except 2 + 2 — see below) HHsnsoz© HH871503A 1.0 0.5 $65
Circuit Number Circuit 4 —- isolated, dedicated circuit HH871504 © 1.0 0.5 $65
Circuitl (2O amp outlet configuration) HH871601 1.0 0.5 $65 Circuit 3 (2 + 2) HH871506 1.0 0.5 $65 Specify Paint.
NOTES: Use with Accelerate” models.
SPECIFYING EXAMPLE: HH871501.S
See page 411 for color options.
MODEL
FOUR-CIRCUIT THREE-CIRCUIT,
3 +1 SEPARATE SHIP LIST
DESCRIPTION 2 + 2 NEUTRALS WEIGHT CUBE PRICE
Data/Electrical Port Kit
Specify color HHTZDP 1.0 0.1 $41 rum-u mil-rm nw
NOTES:
- Data/Electrical Port Kit used for field installations of additional data accessories.
0 Four-circuit components and three-circuit components (with “A" suffix) not designed to be used together. See pages 546—547.
Maximum Receptacle Capacity in Abound Panel Base Raceways
Widths 24 30 36 42 48 60
Maximum of1 duplex per panel side X
Maximum of 2 duplexes per panel side X X X X X
HOWTO SPECIFY
Select Select Model Number Color
See page 411
562 Hon 2026 Workspaces Pricer WORKSTATIONs Effective August 23, 2025, HON will apply a 3% surcharge to all orders.
SYSTEMS
@9Electrical Components
WORKSTAIOTNS
’ “imitate vilth‘Palnf‘ColarDuplex ColorReco‘vnmen‘dé't!
Paint Color Paint Code Duplex Color Duplex Code Black p Black p Brownstone P7D Brownstone EY Charcoal S Charcoal S DesignerWhite PJw DesignerWhite DW Fossil P28 Charcoal S Light Gray G Loft LOFT
LoR LOFT Loft LOFT Muslin T3 Muslin Ts Putty L Black p Silver PR6 Titanium TI Titanium PET Titanium Tl Champagne Metallic T4 Muslin T3 Platinum Metallic TI Titanium Tl
Data]Electrical Port Klt’color‘Re‘é’oMen ac’o'aidiiia‘tewiui;
' 'i'c‘éio
Paint Color Paint Code Data/Port Kl! Color
Data / Port
Kit Code Black P Black P Brownstone P7D Brownstone EY Charcoal S Charcoal S Designer White PJW Designer White DW Fossil P28 Charcoal S
Q Loft Loft LOFT Loft LOFT Muslin T3 Muslin T3 Putty L Black p
Silver PR6 Titanium Tl Titanium Par Titanium Tl Champagne Metallic T4 Muslin T3 Platinum Metallic T1 Titanium Tl
File details come from the government source that posted it. Updated .