Burke County Pumping Apparatus Bid Package 11.pdf
PDF 1 MB Posted
- Attached to
- Pumper Fire Truck
- Solicitation number
- PE-61700-NONST-2027-000000082
- Issued by
- Calhoun County, Georgia
About this file
This is a bid package document issued by Burke County, Georgia for the procurement of a commercial chassis fire pumper truck. The solicitation requests one (1) pumper fire truck to be supplied to Burke County Fire Services. Bidders must submit sealed bids by the specified deadline, with award anticipated following the evaluation of submissions against stated criteria. The contract will be awarded to the lowest qualified bidder meeting all technical and performance specifications outlined in the bid package.
The bid package establishes detailed specifications and requirements for the fire pumper apparatus, including required features, equipment, and performance standards that the supplied vehicle must meet. Pricing should be submitted as a lump sum for the complete unit delivered to Burke County. The document does not indicate any specific set-asides, incumbent contractors, or special funding sources. Burke County reserves the right to reject any or all bids and is not bound to award based solely on price. Bidders should review all technical specifications, delivery requirements, and terms and conditions contained within the complete bid package prior to submission.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Fire Burke County EMS
Emergency Management Agency 277 Highway 24 South Waynesboro, Georgia 30830
Tel. (706) 554-6651 Fax (706) 554-4660
E-Mail: smathews@burkecounty-ga.gov Providing Professional Response and
Peace Of Mind to Burke County Steve Mathews – Chief
REQUEST FOR BIDS
One New Commercial-Chassis Fire Pumper
Two-door cab • 1,250-gpm pump • 1,000-US-gallon water tank
RFB number: __________________________________________
Bid deadline: Nov 30, 2026, at 12:00 PM (Eastern Time)
Bids must be placed in a sealed envelope with the exact text “Burke County EMA Pumping Apparatus Bid” clearly visible on the outside of the envelope.
Delivery/mailing address for sealed bids: Burke County Board of Commissioners c/o County Manager; 602 N Liberty Street Waynesboro, GA 30830
Procurement contact and email: Steven W. Mathews Sr. 762-225-6571 smathews@burkecounty-ga.gov
TOTAL BID AMOUNT
Enter the total delivered base bid from the pricing calculation on the Bid Form. Include applicable taxes and fees; exclude separately priced options and alternate chassis pricing.
Bidder legal name: ______________________________________
Commercial Pumper | Page 1
BURKE COUNTY | COMMERCIAL PUMPER RFB
Invitation and Submission Instructions Burke County requests bids for 1 new "stock" commercial-chassis fire department pumper furnished complete in accordance with Attachment A. Kenworth is preferred; Freightliner is acceptable. The manufacturer shall supply and integrate the chassis, pump, tank, body, electrical systems, and specified equipment.
Attachment A forms the technical basis of this request. Its original section numbering, requirements, equipment quantities, and warranty schedule apply to the offered apparatus.
Submitting a Bid Submit the cover page and signed Bid Form, together with the required technical response, by the deadline and through the submission method shown on the cover. Identify the RFB number and bidder legal name on the submission. Direct questions to the procurement contact shown on the cover. Written addenda issued by the County become part of this request.
Required Technical Response Provide a firm base price, itemized exceptions, and delivery schedule. Include a general arrangement drawing, component makes and models, projected axle loads, and service support information. Identify insurance coverage while the apparatus is in the manufacturer’s custody and during delivery.
Provide the specific model, ratings, dimensions, compartment data, and other disclosures required throughout Attachment A. Include compliance documentation, written warranties, exclusions, service locations, travel charges, claim procedures, and the party coordinating warranty repairs.
Pricing and Options The base apparatus price shall include all specified base equipment, testing, delivery, and training. Show taxes and fees separately on the Bid Form and include them in the total on the cover. Disclose any price-adjustment terms with the bid. Identify the weight, dimensional, and delivery effects of every separately priced option.
Price options separately as required by Attachment A. Do not include optional equipment in the base price unless expressly specified. Describe exceptions by the applicable specification section; an exception does not amend the County’s specifications.
Evaluation and Contract Proposed: The County evaluates bids for conformity with the specifications, total delivered price, delivery schedule, and service and warranty support. Any award is subject to County authorization and an executed purchase contract. Final payment follows written acceptance of the finished apparatus, subject to that contract.
Commercial Pumper | Page 2
Bid Form Complete the pricing below and enter the calculated total bid amount on the cover. Attach only the technical information, itemized disclosures, and supporting schedules required by this request and Attachment A.
Base Bid Calculation Complete apparatus, including delivery and training: $ ______________
Applicable taxes: $ __________________________________________
Other fees (itemize in an attachment if applicable): $ _______________
TOTAL BID AMOUNT = complete apparatus + taxes + other fees. Enter this total in the designated space on the cover.
Separately Priced Options and Alternate For the chassis alternate, state the complete delivered alternate total, including applicable taxes and fees. For options, state the additional delivered price, including applicable taxes and fees.
Identify any credit expressly. Enter “not applicable” only where the alternate or option does not apply.
Freightliner alternate, if Kenworth is the base offer: $ _______________
Foam proportioning system with tank, additional price: $ ____________
Direct tank fill, additional price: $ ______________________________
Extended warranties, additional price: $ _________________________
Attach coverage details for extended warranties and the effects of each option as required by §6.4.
Delivery and Bid Authorization Delivery time after executed contract: __________________________
The undersigned is authorized to submit this bid. The bid includes the required supporting information and identifies all exceptions and price-adjustment terms. The cover total excludes separately priced options and the alternate chassis.
Authorized representative, printed name/title: ____________________
Signature: __________________________ Date: _________________
Bidder contact email/telephone: _______________________________
Commercial Pumper | Page 3
Attachment A — Commercial Pumper Specifications
FIRE APPARATUS PROCUREMENT
Commercial Pumper Specifications Proposed Generic Specification | Two-Door Cab | November 2, 2026
1. General Requirements and Chassis
The manufacturer shall furnish 1 new commercial-chassis fire department pumper with a two-door conventional cab. Kenworth is preferred; Freightliner is acceptable. The completed apparatus shall include a 1,250-gallon-per-minute (gpm) pump and a 1,000-US-gallon water tank.
1.1 Complete Apparatus
The apparatus manufacturer shall supply and integrate the chassis, pump, tank, body, electrical systems, and specified equipment. The manufacturer shall serve as the single point of responsibility for compatibility, testing, delivery, and warranty coordination. All components shall be new and suitable for fire service.
1.2 Standards and Compliance
The completed apparatus shall comply with applicable federal and state vehicle requirements and the applicable automotive fire apparatus provisions of National Fire Protection Association (NFPA) 1900, 2024 edition. This edition shall govern the base proposal. The manufacturer shall furnish the required compliance documentation and identify any purchaser-supplied equipment needed before service.
1.3 Chassis and Powertrain
Component Minimum Requirement
Chassis Kenworth commercial chassis preferred; Freightliner commercial chassis acceptable. State exact model, model year, and production availability.
Configuration Conventional, two-door day cab; single rear axle; 4 × 2 drive. Four-door crew cabs are excluded.
Engine Diesel engine rated at least 330 horsepower. Supply additional power when needed to meet fully loaded road and pump performance. State rated torque and governed speed.
Transmission Heavy-duty fully automatic transmission approved for emergency service, with pump-mode programming and compatible pump-drive provisions.
Axles and suspension Ratings adequate for the completed, fully loaded apparatus and equipment allowance. State front and rear axle, suspension, wheel, and tire ratings.
Braking Full air brakes, antilock braking, parking brake, and compatible auxiliary engine or exhaust braking. Provide stability control when available for the offered chassis.
Fuel and emissions Minimum 50-gallon diesel fuel capacity. Provide compliant emissions equipment and diesel exhaust fluid system, with protected, accessible fill points.
Commercial Pumper | Page 4
2. Cab, Dimensions, and Vehicle Safety
2.1 Two-Person Cab
The cab shall have 2 doors and 2 forward-facing seating positions: driver and officer. Each position shall have an individual seat, head restraint, and three-point seat belt. The cab shall include heating, air conditioning, defrosting, power steering, and heated exterior mirrors. Provide slip-resistant entry steps, grab handles, and entry lighting.
A control console shall place warning-light and siren controls within reach without interfering with seat belts, airbags, or cab access. Provide secure storage for helmets and small equipment. Provide space, fused power, and antenna-routing provisions for purchaser-supplied radio equipment. Base seats shall use conventional backs; self-contained breathing apparatus (SCBA) seat inserts are excluded.
2.2 Size and Maneuverability
Item Requirement
Overall length Maximum 32 feet, including permanent equipment in travel position.
Overall height Maximum 10 feet, including permanent equipment in travel position.
Body width Maximum 100 inches, excluding mirrors and legally permitted projections.
State overall operating width.
Wheelbase and turning Use the shortest practical wheelbase consistent with safe loading and service access. State wheelbase, curb-to-curb turning diameter, and rear overhang.
Approach and departure Minimum 8 degrees each at fully loaded condition, or greater where required by the governing standard.
Travel speed Electronically governed maximum of 65 mph, or lower where required by the governing standard, tire rating, or chassis limits.
2.3 Load Capacity and Balance
The design shall carry full water and fuel tanks, all installed and supplied equipment, 2 occupants at the governing standard’s allowance, and at least 2,000 pounds of purchaser-supplied equipment. This equipment allowance shall be additional to installed and manufacturer-supplied equipment. The bidder shall submit projected axle loads and remaining payload.
No gross vehicle, axle, suspension, wheel, or tire rating shall be exceeded. The manufacturer shall verify side-to-side loading, center of gravity, stability, and compliance with chassis loading limits. Provide certified final axle weights at the specified fully loaded condition, using secured ballast for equipment not present.
2.4 Safety and Service Access
Provide a rear-view camera with in-cab display, reverse alarm, tire-pressure indication for every tire, and a visible and audible cab warning for open compartment doors or equipment not secured for travel.
Provide front and rear chassis-rated towing points. Protect wiring and hoses from heat, abrasion, road debris, and moving components.
Provide required safety labels and an in-cab plate stating actual completed height, length, and gross vehicle weight rating. Preserve access to engine, transmission, batteries, filters, and emissions service points. Chassis modifications shall follow chassis-manufacturer requirements and preserve applicable warranties.
Commercial Pumper | Page 5
3. Fire Pump and Plumbing
3.1 Pump Performance
Provide a midship centrifugal fire pump with a minimum rated capacity of 1,250 gpm. Pump make and model are open to competitive selection, but Hale Qmax is preferred. Provide a driveline-operated pump transmission and a serviceable mechanical seal. The engine, pump ratio, and driveline shall support all required ratings without exceeding component limits.
Required Flow Net Pump Pressure
1,250 gpm 150 pounds per square inch (psi)
875 gpm 200 psi
625 gpm 250 psi
3.2 Pump Controls and Protection
Locate the pump operator’s panel on the left side. Provide illuminated, permanently labeled, color-coded controls; master intake and discharge gauges; and an individual pressure gauge for each attack, supply, crosslay, and monitor discharge. Provide tank-level displays at the pump panel and in the cab.
Provide an electronic pressure governor with pressure and engine-speed modes, return-to-idle control, engine monitoring, and low-water protection. Include a priming system, intake-pressure relief, and pump cooling or recirculation. Provide a master drain, individual line drains, test connections, and corrosion protection suitable for the pump materials.
Provide in-cab pump-shift controls and pump-engaged indicators. Interlocks shall prevent remote throttle operation until the pump and transmission are correctly engaged. Auxiliary braking shall disengage in pump mode. Provide an emergency pump-shift method and clearly marked operating instructions.
3.3 Intake and Discharge Schedule
Connection Quantity and Arrangement
Main intakes 2 total: 1 on each side; minimum 6-inch connection with screen and cap.
Auxiliary intake 1 left-side, 2½-inch gated intake with screen, bleeder, and plug.
Left-side discharges 2 independently controlled, 2½-inch outlets with caps and drains.
Right-side discharges 2 independently controlled, 2½-inch outlets with caps and drains.
Rear Discharge 1 independently controlled, 2½-inch outlet with cap and drain.
Crosslays 2 independent preconnects, each with minimum 2-inch valve and piping, terminating in a 1½-inch swivel connection.
Monitor connection 1 minimum 3-inch valved, capped connection above the pump module.
Tank connections Minimum 3-inch tank-to-pump line and 2-inch tank-fill line, each independently controlled.
3.4 Piping and Connections
Use corrosion-resistant stainless-steel piping and pressure- and vacuum-rated flexible connections suitable for the application. Use serviceable, full-flow valves and slow-close controls where required.
Provide National Standard Thread hose connections. The manufacturer shall confirm purchaser hose compatibility before fabrication. Rate every component for its maximum operating pressure and provide access for maintenance.
Commercial Pumper | Page 6
4. Water Tank, Body, and Hose Storage
4.1 Water Tank
Provide a certified minimum 1,000-US-gallon polypropylene water tank with internal baffles, venting, and overflow. Include a covered fill tower with screen, a sump with anti-swirl device, and drain and cleanout access. Support and secure the tank according to the tank manufacturer’s requirements while allowing chassis frame movement. Provide access for inspection and removal without destructive body disassembly.
The tank-to-pump system shall deliver at least 500 gpm from the onboard tank under the governing standard’s test conditions. The bidder shall state its guaranteed flow. The tank-fill system shall prevent unintended tank pressurization. Provide a separately priced direct tank-fill option with backflow protection and compatible purchaser connection.
4.2 Body Construction
Provide a corrosion-resistant aluminum fire apparatus body with an independent pump module. Use engineered supports that accommodate normal chassis movement. Isolate dissimilar metals. Provide replaceable wheel-well liners, lower-body rub rails, corrosion-resistant hardware, and access panels for wiring and plumbing service. State body alloy, material thicknesses, mounting method, and structural warranty.
Feature Minimum Requirement
Side compartments 3 compartments per side: ahead of, above, and behind the rear wheel.
Provide full-height front and rear compartments where packaging allows.
Rear compartment 1 rear-center equipment compartment with access independent of hose deployment.
Internal Storage Internal storage for ladders and pike poles.
Doors Weather-resistant, lockable aluminum roll-up doors with common keying and door-open indication.
Interior fittings Drainage, ventilation, durable washable finish, adjustable shelf tracks, and at least 6 adjustable shelves total. Each shelf rated at least 250 pounds and labeled.
Compartment data Provide clear door openings, usable dimensions, shelf ratings, and total usable compartment volume in the proposal.
Personnel access Slip-resistant running boards, rear step, climbing steps, and grab rails allowing three-point contact at designated access areas.
4.3 Hosebed and Crosslays
Provide a ventilated rear hosebed with at least 70 cubic feet of usable hose storage, excluding obstructions. Include at least 2 adjustable full-length divider. Include mounting hardware for hard suction.
Each crosslay shall hold at least 200 feet of 1¾-inch hose and allow deployment from either side. Size beds using actual hose dimensions, including couplings, before construction.
Provide hosebed and crosslay covers or positive restraints that retain hose during vehicle travel and allow gloved release. Keep fill-tower access clear and protect hose from sharp edges. Attack and supply hose are purchaser-supplied unless added by separate purchase.
4.4 Equipment Storage
Provide secure mounting for the specified ground ladders and 2 hard-suction sections, plus storage for 2 pike poles. Internal storage is preferred. Provide 4 protected SCBA cylinder compartments sized for purchaser cylinders. All external equipment mounts shall positively retain their loads during travel and allow safe removal.
Commercial Pumper | Page 7
5. Electrical, Lighting, Finish, and Equipment
5.1 Electrical System
Provide a 12-volt negative-ground apparatus electrical system with labeled wiring, protected circuits, sealed exterior connectors, and accessible distribution panels. Size the alternator and batteries for the calculated emergency-service electrical load. Include high-idle control, automatic load management, low-voltage warning, and an accessible master battery disconnect that preserves required chassis circuits.
Provide an automatic battery charger sized for chassis batteries and standby accessory loads, an external charge-status display, and a driver-side 120-volt, 20-amp automatic-eject shoreline inlet. Supply the compatible cord connector. Provide an auxiliary air compressor to maintain air-system pressure while parked, without compromising brake-system protection.
5.2 Warning and Work Lighting
System Requirement
Emergency warning LED roof lightbar and perimeter warning lights providing front, intersection, side, and rear coverage. Meet governing photometric requirements and Georgia vehicle requirements.
Warning controls Master warning switch, separately controlled functions, and automatic response-mode and parked-mode switching. Control forward-facing white warning lights as required.
Audible warning Electronic siren with public-address capability and minimum 100-watt speaker; retain chassis horn.
Scene lighting Minimum 4 LED scene lights: 1 each side and 2 rear, independently switched by area.
Work lighting LED pump-panel, pump-enclosure, compartment, hosebed, entry-step, and ground lighting. Compartment lights shall operate with door opening.
Road lighting Compliant headlights, stop lamps, turn signals, marker lights, license-plate light, and reverse lights.
5.3 Paint and Reflective Markings
Provide a single-color red cab and body with a matched automotive-grade finish. Protect exposed and hidden surfaces against corrosion. Provide reflective side and front striping and rear red and fluorescent yellow-green chevrons meeting the governing standard. Submit paint samples and marking drawings for purchaser approval before application. Include department identification on both cab doors and unit identification at the front and rear; artwork shall use purchaser-approved lettering.
5.4 Manufacturer-Supplied Loose Equipment
QTY ITEM / DESCRIPTION
1 Elkhart 8297 1000 GPM deck gun, complete with top-mount adapter, gun, stream shaper, stacked tips, and ground mount with chains
1 Elkhart 18-inch extension for deck gun
1 Alcolite 14-foot roof ladder
1 Alcolite 24-foot two-section extension ladder
1 Alcolite 10-foot attic ladder
2 6-inch × 10-foot flexible hard-suction hoses with lightweight NST couplings (may be in hose bed)
2 10-foot fiberglass pike poles
4 Ziamatic air-pack brackets, installed in the compartment over the rear wheels on the driver’s side
4 50-foot sections of 1-inch booster hose with lightweight NST chrome couplings
2 South Park axe blade brackets
Commercial Pumper | Page 8
QTY ITEM / DESCRIPTION
2 South Park axe handle brackets
3 Beco heavy-duty fire extinguisher brackets
1 Red Head triple wrench holder with two spanner wrenches and one hydrant wrench
1 Zico bolt-cutter mount
1 Zico horizontal 1.25-inch quick-bar mounting bracket
1 South Park pinch-point pry-bar holder set
2 Task Force Tips Handline Nozzles, 1.5-inch female, 100 psi, adjustable 95–300 GPM
The purchaser supplies remaining operational loose equipment. The manufacturer shall provide an itemized list of any additional equipment required by the governing standard for placement in service.
Commercial Pumper | Page 9
6. Testing, Delivery, Warranty, and Proposal
6.1 Inspection and Acceptance
The manufacturer shall obtain purchaser approval of the general arrangement drawing, pump panel, compartment layout, and equipment mounts before fabrication. Approval shall not relieve the manufacturer of meeting performance, weight, or safety requirements. Changes affecting price or delivery require written purchaser approval.
Before delivery, provide independent third-party pump certification for the completed apparatus, including the specified flow-pressure ratings, drafting, priming, and tank-to-pump flow. Complete the required electrical-load, braking, road, stability, and safety-system tests. Provide certified axle weights and an as-built compliance statement with test reports.
The purchaser shall inspect the apparatus and witness an operational demonstration before written acceptance. The manufacturer shall correct contract deficiencies and repeat affected tests at its expense.
Delivery alone does not constitute acceptance. Final payment is due after written acceptance, subject to the executed purchase contract.
6.2 Delivery and Training
Include delivery to the purchaser’s designated fire station with full fuel and diesel exhaust fluid tanks.
Provide at least 1 full day of on-site operator training covering driving checks, pump operation, drafting, safety systems, and routine maintenance. Supply electronic chassis, pump, tank, body, and component manuals; as-built electrical and plumbing diagrams; parts lists; and preventive-maintenance schedules.
6.3 Minimum Warranty Schedule
System Required Coverage
Complete apparatus 1 year against defects in materials and workmanship; parts and labor.
Body structure 10 years against structural defects.
Stainless steel plumbing 10 years against defects in materials and workmanship.
Apparatus electrical 2 years against defects in materials and workmanship.
Paint 5 years; disclose any prorating and exclusions.
Water tank Lifetime for the original apparatus; disclose repair, labor, removal, and freight coverage.
Chassis, engine, transmission, pump
Provide each original manufacturer’s written warranty and available extended coverage.
Warranty periods shall begin at purchaser acceptance wherever available. Disclose any component warranty that begins earlier, all exclusions, service locations, travel charges, and claim procedures.
Identify the party responsible for coordinating warranty repairs.
6.4 Required Proposal and Separately Priced Options
Submit a firm base price, itemized exceptions, and delivery schedule. Include a general arrangement drawing, component makes and models, projected axle loads, and service support information. State separately any taxes, fees, or price-adjustment terms. Identify insurance coverage while the apparatus is in the manufacturer’s custody and during delivery.
Provide separate prices for a Freightliner chassis alternate when Kenworth is the base offer; a foam proportioning system with tank; direct tank fill; and extended warranties. Identify weight, dimensional, and delivery effects of each option. Optional equipment shall not be included in the base price unless expressly specified.
Commercial Pumper Checklist | Page 1
Commercial Pumper Checklist Sections 1–5 and 6.3
1. General Requirements and Chassis
Requirement / Item Yes No
The manufacturer shall furnish 1 new commercial-chassis fire department pumper with a two-door conventional day cab.
Kenworth is preferred; Freightliner is acceptable.
The completed apparatus shall include a 1,250-gallon-per-minute (gpm) pump and a 1,000-US-gallon water tank.
1.1 Complete Apparatus
Requirement / Item Yes No
The apparatus manufacturer shall supply and integrate the chassis, pump, tank, body, electrical systems, and specified equipment.
The manufacturer shall serve as the single point of responsibility for compatibility, testing, delivery, and warranty coordination.
All components shall be new and suitable for fire service.
1.2 Standards and Compliance
Requirement / Item Yes No
The completed apparatus shall comply with applicable federal and state vehicle requirements and the applicable automotive fire apparatus provisions of National Fire Protection Association (NFPA) 1900, 2024 edition.
This edition shall govern the base proposal.
The manufacturer shall furnish the required compliance documentation and identify any purchaser-supplied equipment needed before service.
1.3 Chassis and Powertrain
Requirement / Item Yes No
Chassis: Kenworth commercial chassis preferred; Freightliner commercial chassis acceptable. State exact model, model year, and production availability.
Configuration: Conventional, two-door cab; single rear axle; 4 × 2 drive. Four-door crew cabs are excluded.
Engine: Diesel engine rated at least 330 horsepower. Supply additional power when needed to meet fully loaded road and pump performance. State rated torque and governed speed.
Transmission: Heavy-duty fully automatic transmission approved for emergency service, with pump-mode programming and compatible pump-drive provisions.
Axles and suspension: Ratings adequate for the completed, fully loaded apparatus and equipment allowance. State front and rear axle, suspension, wheel, and tire ratings.
Braking: Full air brakes, antilock braking, parking brake, and compatible auxiliary engine or exhaust braking. Provide stability control when available for the offered chassis.
Attachment A Checklist
COMMERCIAL PUMPER | YES/NO CHECKLIST
Commercial Pumper Checklist | Page 2
Requirement / Item Yes No
Fuel and emissions: Minimum 50-gallon diesel fuel capacity. Provide compliant emissions equipment and diesel exhaust fluid system, with protected, accessible fill points.
2. Cab, Dimensions, and Vehicle Safety
2.1 Two-Person Cab
Requirement / Item Yes No
The cab shall have 2 doors and 2 forward-facing seating positions: driver and officer.
Each position shall have an individual seat, head restraint, and three-point seat belt.
The cab shall include heating, air conditioning, defrosting, power steering, and heated exterior mirrors.
Provide slip-resistant entry steps, grab handles, and entry lighting.
A control console shall place warning-light and siren controls within reach without interfering with seat belts, airbags, or cab access.
Provide secure storage for helmets and small equipment.
Provide space, fused power, and antenna-routing provisions for purchaser-supplied radio equipment.
Base seats shall use conventional backs; self-contained breathing apparatus (SCBA) seat inserts are excluded.
2.2 Size and Maneuverability
Requirement / Item Yes No
Overall length: Maximum 32 feet, including permanent equipment in travel position.
Overall height: Maximum 10 feet, including permanent equipment in travel position.
Body width: Maximum 100 inches, excluding mirrors and legally permitted projections. State overall operating width.
Wheelbase and turning: Use the shortest practical wheelbase consistent with safe loading and service access. State wheelbase, curb-to-curb turning diameter, and rear overhang.
Approach and departure: Minimum 8 degrees each at fully loaded condition, or greater where required by the governing standard.
Travel speed: Electronically governed maximum of 65 mph, or lower where required by the governing standard, tire rating, or chassis limits.
2.3 Load Capacity and Balance
Requirement / Item Yes No
The design shall carry full water and fuel tanks, all installed and supplied equipment, 2 occupants at the governing standard’s allowance, and at least 2,000 pounds of purchaser-supplied equipment.
This equipment allowance shall be additional to installed and manufacturer-supplied equipment.
The bidder shall submit projected axle loads and remaining payload.
No gross vehicle, axle, suspension, wheel, or tire rating shall be exceeded.
Commercial Pumper Checklist | Page 3
Requirement / Item Yes No
The manufacturer shall verify side-to-side loading, center of gravity, stability, and compliance with chassis loading limits.
Provide certified final axle weights at the specified fully loaded condition, using secured ballast for equipment not present.
2.4 Safety and Service Access
Requirement / Item Yes No
Provide a rear-view camera with in-cab display, reverse alarm, tire-pressure indication for every tire, and a visible and audible cab warning for open compartment doors or equipment not secured for travel.
Provide front and rear chassis-rated towing points.
Protect wiring and hoses from heat, abrasion, road debris, and moving components.
Provide required safety labels and an in-cab plate stating actual completed height, length, and gross vehicle weight rating.
Preserve access to engine, transmission, batteries, filters, and emissions service points.
Chassis modifications shall follow chassis-manufacturer requirements and preserve applicable warranties.
3. Fire Pump and Plumbing
3.1 Pump Performance
Requirement / Item Yes No
Provide a midship centrifugal fire pump with a minimum rated capacity of 1,250 gpm.
Pump make and model are open to competitive selection, but Hale Qmax is preferred.
Provide a driveline-operated pump transmission and a serviceable mechanical seal.
The engine, pump ratio, and driveline shall support all required ratings without exceeding component limits.
1,250 gpm: 150 pounds per square inch (psi)
875 gpm: 200 psi
625 gpm: 250 psi
3.2 Pump Controls and Protection
Requirement / Item Yes No
Locate the pump operator’s panel on the left side.
Provide illuminated, permanently labeled, color-coded controls; master intake and discharge gauges; and an individual pressure gauge for each attack, supply, crosslay, and monitor discharge.
Provide tank-level displays at the pump panel and in the cab.
Provide an electronic pressure governor with pressure and engine-speed modes, return-to-idle control, engine monitoring, and low-water protection.
Include a priming system, intake-pressure relief, and pump cooling or recirculation.
Provide a master drain, individual line drains, test connections, and corrosion protection suitable for the pump materials.
Commercial Pumper Checklist | Page 4
Requirement / Item Yes No
Provide in-cab pump-shift controls and pump-engaged indicators.
Interlocks shall prevent remote throttle operation until the pump and transmission are correctly engaged.
Auxiliary braking shall disengage in pump mode.
Provide an emergency pump-shift method and clearly marked operating instructions.
3.3 Intake and Discharge Schedule
Requirement / Item Yes No
Main intakes: 2 total: 1 on each side; minimum 6-inch connection with screen and cap.
Auxiliary intake: 1 left-side, 2½-inch gated intake with screen, bleeder, and plug.
Left-side discharges: 2 independently controlled, 2½-inch outlets with caps and drains.
Right-side discharges: 2 independently controlled, 2½-inch outlets with caps and drains.
Rear Discharge: 1 independently controlled, 2½-inch outlet with cap and drain.
Crosslays: 2 independent preconnects, each with minimum 2-inch valve and piping, terminating in a 1½-inch swivel connection.
Monitor connection: 1 minimum 3-inch valved, capped connection above the pump module.
Tank connections: Minimum 3-inch tank-to-pump line and 2-inch tank-fill line, each independently controlled.
3.4 Piping and Connections
Requirement / Item Yes No
Use corrosion-resistant stainless-steel piping and pressure- and vacuum-rated flexible connections suitable for the application.
Use serviceable, full-flow valves and slow-close controls where required.
Provide National Standard Thread hose connections except the specified Storz adapter.
The manufacturer shall confirm purchaser hose compatibility before fabrication.
Rate every component for its maximum operating pressure and provide access for maintenance.
4. Water Tank, Body, and Hose Storage
4.1 Water Tank
Requirement / Item Yes No
Provide a certified minimum 1,000-US-gallon polypropylene water tank with internal baffles, venting, and overflow.
Include a covered fill tower with screen, a sump with anti-swirl device, and drain and cleanout access.
Support and secure the tank according to the tank manufacturer’s requirements while allowing chassis frame movement.
Provide access for inspection and removal without destructive body disassembly.
Commercial Pumper Checklist | Page 5
Requirement / Item Yes No
The tank-to-pump system shall deliver at least 500 gpm from the onboard tank under the governing standard’s test conditions.
The bidder shall state its guaranteed flow.
The tank-fill system shall prevent unintended tank pressurization.
Provide a separately priced direct tank-fill option with backflow protection and compatible purchaser connection.
4.2 Body Construction
Requirement / Item Yes No
Provide a corrosion-resistant aluminum fire apparatus body with an independent pump module.
Use engineered supports that accommodate normal chassis movement.
Isolate dissimilar metals.
Provide replaceable wheel-well liners, lower-body rub rails, corrosion-resistant hardware, and access panels for wiring and plumbing service.
State body alloy, material thicknesses, mounting method, and structural warranty.
Side compartments: 3 compartments per side: ahead of, above, and behind the rear wheel. Provide full-height front and rear compartments where packaging allows.
Rear compartment: 1 rear-center equipment compartment with access independent of hose deployment.
Internal Storage: Internal storage for ladders and pike poles.
Doors: Weather-resistant, lockable aluminum roll-up doors with common keying and door-open indication.
Interior fittings: Drainage, ventilation, durable washable finish, adjustable shelf tracks, and at least 6 adjustable shelves total. Each shelf rated at least 250 pounds and labeled.
Compartment data: Provide clear door openings, usable dimensions, shelf ratings, and total usable compartment volume in the proposal.
Personnel access: Slip-resistant running boards, rear step, climbing steps, and grab rails allowing three-point contact at designated access areas.
4.3 Hosebed and Crosslays
Requirement / Item Yes No
Provide a ventilated rear hosebed with at least 70 cubic feet of usable hose storage, excluding obstructions.
Include at least 2 adjustable full-length dividers.
Include mounting hardware for hard suction.
Each crosslay shall hold at least 200 feet of 1¾-inch hose and allow deployment from either side.
Size beds using actual hose dimensions, including couplings, before construction.
Provide hosebed and crosslay covers or positive restraints that retain hose during vehicle travel and allow gloved release.
Keep fill-tower access clear and protect hose from sharp edges.
Attack and supply hose are purchaser-supplied unless added by separate purchase.
Commercial Pumper Checklist | Page 6
4.4 Equipment Storage
Requirement / Item Yes No
Provide secure mounting for the specified ground ladders and 2 hard-suction sections, plus storage for 2 pike poles. Internal storage is preferred. Hard suction may be mounted inside hosebed.
Provide 4 SCBA cylinder mounting brackets sized for purchaser cylinders.
All external equipment mounts shall positively retain their loads during travel and allow safe removal.
5. Electrical, Lighting, Finish, and Equipment
5.1 Electrical System
Requirement / Item Yes No
Provide a 12-volt negative-ground apparatus electrical system with labeled wiring, protected circuits, sealed exterior connectors, and accessible distribution panels.
Size the alternator and batteries for the calculated emergency-service electrical load.
Include high-idle control, automatic load management, low-voltage warning, and an accessible master battery disconnect that preserves required chassis circuits.
Provide an automatic battery charger sized for chassis batteries and standby accessory loads, an external charge-status display, and a driver-side 120-volt, 20-amp automatic-eject shoreline inlet.
Supply the compatible cord connector.
Provide an auxiliary air compressor to maintain air-system pressure while parked, without compromising brake-system protection.
5.2 Warning and Work Lighting
Requirement / Item Yes No
Emergency warning: LED roof lightbar and perimeter warning lights providing front, intersection, side, and rear coverage. Meet governing photometric requirements and Georgia vehicle requirements.
Warning controls: Master warning switch, separately controlled functions, and automatic response-mode and parked-mode switching. Control forward-facing white warning lights as required.
Audible warning: Electronic siren with public-address capability and minimum 100-watt speaker; retain chassis horn.
Scene lighting: Minimum 4 LED scene lights: 1 each side and 2 rear, independently switched by area.
Work lighting: LED pump-panel, pump-enclosure, compartment, hosebed, entry-step, and ground lighting. Compartment lights shall operate with door opening.
Road lighting: Compliant headlights, stop lamps, turn signals, marker lights, license-plate light, and reverse lights.
5.3 Paint and Reflective Markings
Requirement / Item Yes No
Provide a single-color red cab and body with a matched automotive-grade finish.
Commercial Pumper Checklist | Page 7
Requirement / Item Yes No
Protect exposed and hidden surfaces against corrosion.
Provide reflective side and front striping and rear red and fluorescent yellow-green chevrons meeting the governing standard.
Submit paint samples and marking drawings for purchaser approval before application.
Include department identification on both cab doors and unit identification at the front and rear; artwork shall use purchaser-approved lettering.
5.4 Manufacturer-Supplied Loose Equipment
Requirement / Item Yes No
Quantity 1 — Elkhart 8297 1000 GPM deck gun, complete with top-mount adapter, gun, stream shaper, stacked tips, and ground mount with chains
Quantity 1 — Elkhart 18-inch extension for deck gun
Quantity 1 — Alcolite 14-foot roof ladder
Quantity 1 — Alcolite 24-foot two-section extension ladder
Quantity 1 — Alcolite 10-foot attic ladder
Quantity 2 — 6-inch × 10-foot flexible hard-suction hoses with lightweight NST couplings (may be in hose bed)
Quantity 2 — 10-foot fiberglass pike poles
Quantity 4 — Ziamatic air-pack brackets, installed in the compartment over the rear wheels on the driver’s side
Quantity 4 — 50-foot sections of 1-inch booster hose with lightweight NST chrome couplings
Quantity 2 — South Park axe blade brackets
Quantity 2 — South Park axe handle brackets
Quantity 3 — Beco heavy-duty fire extinguisher brackets
Quantity 1 — Red Head triple wrench holder with two spanner wrenches and one hydrant wrench
Quantity 1 — Zico bolt-cutter mount
Quantity 1 — Zico horizontal 1.25-inch quick-bar mounting bracket
Quantity 1 — South Park pinch-point pry-bar holder set
Quantity 2 — Task Force Tips Handline Nozzles, 1.5-inch female, 100 psi, adjustable 95–300 GPM
The purchaser supplies remaining operational loose equipment.
The manufacturer shall provide an itemized list of any additional equipment required by the governing standard for placement in service.
6. Testing, Delivery, Warranty, and Proposal
6.3 Minimum Warranty Schedule
Requirement / Item Yes No
Complete apparatus: 1 year against defects in materials and workmanship; parts and labor.
Body structure: 10 years against structural defects.
Commercial Pumper Checklist | Page 8
Requirement / Item Yes No
Stainless steel plumbing: 10 years against defects in materials and workmanship.
Apparatus electrical: 2 years against defects in materials and workmanship.
Paint: 5 years; disclose any prorating and exclusions.
Water tank: Lifetime for the original apparatus; disclose repair, labor, removal, and freight coverage.
Chassis, engine, transmission, pump: Provide each original manufacturer’s written warranty and available extended coverage.
Warranty periods shall begin at purchaser acceptance wherever available.
Disclose any component warranty that begins earlier, all exclusions, service locations, travel charges, and claim procedures.
Identify the party responsible for coordinating warranty repairs.
File details come from the government source that posted it. Updated .