BROCHURE_10-2226-01R1_FA_Operable Partitions DELLC.pdf

PDF 8 MB Posted

Attached to
Z2AZ--Modernfold Room Divider PM&R | Lebanon VAMC
Solicitation number
36C24424Q0799
Issued by

About this file

This document is a technical data sheet for the Acousti-Seal Legacy Electric (933E) operable partition system manufactured by Modernfold, Inc. The Acousti-Seal Legacy Electric is an electrically operated, continuously hinged operable partition with features such as automatic floor seals, integrated safety components, and a choice of suspension systems and panel finishes. The document provides detailed specifications on the panel construction, operation, sound ratings, and available options. It also includes technical drawings and diagrams illustrating the system components and installation details. This technical data appears to be for informational purposes and does not appear to be directly related to a federal contract opportunity.

The related federal contract opportunity is for the procurement of Modernfold room dividers for the Lebanon VA Medical Center. The solicitation number is 36C24424Q0799 and the contract is being issued by the Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 4. The required products appear to be Modernfold operable partitions and associated services for repair, maintenance, and replacement.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com. 1

Acousti-Seal® Legacy® Electric (933E) Technical Data 10 22 26 (10650) Operable Partitions

ACOUSTI-SEAL® LEGACY® SERIES TECHNICAL DATA

• Continuously Hinged Electric Partitions Provide Effortless Operation

• Extends and Stacks with the Activation of Push Button Switches

• Integrated Safety with Key-Activated Two-Button Operation

• Two Year Warranty on Partition System

• Lifetime Warranty on Standard Hinges

• Operable Bottom Floor Seal Sets Automatically when Partition is Fully Extended

• Used in Hotel Ballrooms, Civic/Convention Centers, Classrooms, Gymnasiums, Meeting Rooms, Conference Rooms, and Multipurpose Rooms

Modernfold Model Acousti-Seal® Legacy® Electric (933E) Electrically Operated, Continuously Hinged Partitions

This specification along with product information and model details can be downloaded from www.modernfold.com

SPECIFICATION - SECTION 10 22 26 (10650) OPERABLE PARTITIONS

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section.

1.2 SUMMARY

A. This Section includes the following:

1. Electrically operated, continuously hinged partitions.

B. Related Sections include the following:

1. Division 03 Sections for concrete tolerances required.

2. Division 05 Sections for primary structural support, including pre-punching of support members by structural steel supplier per operable partition supplier’s template.

3. Division 06 Sections for wood framing and supports, and all blocking at head and jambs as required.

4. Division 09 Sections for wall and ceiling framing at head and jambs.

1.3 QUALITY ASSURANCE

A. Installer Qualifications: An experienced installer who is certified in writing by the operable partition manufacturer, as qualified to install the manufacturer’s partition systems for work similar in material, design, and extent to that indicated for this Project.

B. Acoustical Performance: Test operable partitions in an independent acoustical laboratory in accordance with ASTM E90 test procedure and classified in accordance with ASTM E413 to attain no less than the STC rating specified. Provide a complete and unedited written test report by the testing laboratory upon request.

C. Preparation of the opening shall conform to the criteria set forth per ASTM E557 Standard Practice for Architectural Application and Installation of Operable Partitions.

D. The operable wall must be manufactured by a certified ISO-9001-2015 company or an equivalent quality control system.

1.4 REFERENCE STANDARDS

A. ASTM International

1. ASTM E557 Standard Practice for Architectural Application and Installation of Operable Partitions.

2. ASTM E90 - Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements.

3. ASTM C1036 - Standard Specification for Flat Glass.

4. ASTM C1048 - Heat-Treated Flat Glass—Kind HS, Kind FT Coated and Uncoated Glass.

5. ASTM E84 - Surface Burning Characteristics of Building Materials.

6. ASTM E413 - Classification for Rating Sound Insulation

B. Health Product Declaration Collaborative

1. Health Product Declaration Open Standard v2.1 C. International Standards Organization

1. ISO 14021 - Environmental Labels and Declarations - Self-Declared Environmental Claims (Type II Environmental Labeling).

2. ISO 14025:2011-10, Environmental Labels and Declarations - Type III Environmental Declarations - Principles and Procedures.

3. ISO 14040:2009-11, Environmental Management

- Life Cycle Assessment - Principles and Framework.

4. ISO 14044:2006-10, Environmental Management

- Life Cycle Assessment - Requirements and Guidelines.

Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.2

Technical Data 10 22 26 (10650) Operable Partitions

ACOUSTI-SEAL® LEGACY® SERIES TECHNICAL DATA

5. ISO 21930 – Sustainability in Buildings and

Civil Engineering Works — Core Rules for Environmental Product Declarations of Construction Products and Services.

D. Other Standards

1. ADA – Americans with Disabilities Act.

2. UL 508A – Standard for Industrial Control Panels

3. NFPA 70 – National Electrical Code

4. ANSI Z97.1 - Safety Glazing Materials Used in

Buildings.

5. CPSC 16 CFR 1201 - Safety Standard for

Architectural Glazing Materials.

6. NEMA LD3 - High Pressure Decorative

Laminates.

1.5 SUBMITTALS

A. Product Data: Material descriptions, construction details, finishes, installation details, and operating instructions for each type of operable partition, component, and accessory specified.

B. Shop Drawings: Show location and extent of operable partitions. Include plans, elevations, sections, details, attachments to other construction, and accessories. Indicate dimensions, weights, conditions at openings, and at storage areas, and required installation, storage, and operating clearances. Indicate location and installation requirements for hardware and track, including floor tolerances required and direction of travel.

Indicate blocking to be provided by others.

C. Setting Drawings: Show imbedded items and cutouts required in other work, including support beam punching template.

D. Samples: Color samples demonstrating full range of finishes available by architect. Verification samples will be available in same thickness and material indicated for the work.

E. Reports: Provide a complete and unedited written sound test report indicating test specimen matches product as submitted.

F. Create spaces that are healthy for occupants.

1. Furnish products and materials with Health

Product Declaration (HPD), Manufacturer Inventory, or other material health disclosure documentation. Products without an HPD or other disclosure documentation are not acceptable.

G. Furnish materials that generate the least amount of pollution.

1. Furnish products and materials that have third party verified environmental product declarations (EPD’s). Consider products and materials that have optimized environmental performance (reduced life cycle impacts).

Products without an EPD or other disclosure documentation are not acceptable.

H. Buy American: Operable partition to be manufactured in the United States in compliance with applicable U.S. Federal Trade Commission (FTC) and U.S. Customs Service and Border Protections regulations and be labeled “Made in America”.

1.6 DELIVERY, STORAGE, AND HANDLING

A. Clearly mark packages and panels with numbering systems used on Shop Drawings. Do not use permanent markings on panels.

B. Protect panels during delivery, storage, and handling to comply with manufacturer’s direction and as required to prevent damage.

1.7 WARRANTY

A. Provide written warranty by manufacturer of operable partitions agreeing to repair or replace any components with manufacturing defects.

B. Warranty period: Two (2) years.

PART 2 – PRODUCTS

2.1 MANUFACTURERS, PRODUCTS, AND OPERATION

A. Manufacturers: Subject to compliance with requirements, provide product by the following:

1. Modernfold, Inc.

B. Panels to be manufactured in the U.S.A.

C. Products: Subject to compliance with the requirements, provide the following product:

1. Acousti-Seal Legacy – Electric Partition (933E) electrically operated continuously hinged operable partition.

2.2 OPERATION

A. Acousti-Seal Legacy – Electric Partition (933E):

Series of continuously hinged flat panels, electrically operated, top supported with operable floor seals.

B. Final Closure (select one):

1. Side Jamb with overlapping trail panel.

2. Side Jamb with overlapping trail panel with

“Modernfold Presto Automation Package”. (For complete specification see Presto Package brochure Form #2514)

3. Side Seal with pocket door interface (Remote stack only).

C. Partition shall be operated by:

1. Two push button control stations wired in series and located on opposite sides and opposite ends of the partition. Control stations shall

Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com. 3

Technical Data 10 22 26 (10650) Operable Partitions

ACOUSTI-SEAL® LEGACY® SERIES TECHNICAL DATA

be activated by key switch at stack end of partition.

2. Modernfold Presto ® Automation Package with Touch Screen Operator Control Station by Modernfold, Inc.

3. Motor unit shall be reversible, continuous duty, and class A insulated. Motor unit shall have NEMA MG 1 service factor, high starting torque, thermal overload protection, and open/drip proof enclosure. Motor assembly shall have wiring compliant with NFPA 70, 24-volt controls, compliant with UL 508A, and speed of 28 feet/ minute. The drive unit motor shall be equipped with outboard limit switches to prevent over-extension. A positive chain drive attached to the lead panel shall pull the partition across the opening. Cable, belt, or other friction type drives will not be accepted.

D. Electric motor shall be (select one):

1. 115-volt, 1-phase, 1 HP, 14.0 FLA

2. 208/230-volt, 1-phase, 1 HP, 7.0 FLA

3. 208/230-volt, 3-phase, 1 HP, 4.5 FLA

4. 460-volt, 3-phase, 1 HP, 2.0 FLA

5. 208/230-volt, 3-phase, 1-1/2 HP, 5.2 FLA

2.3 PANEL CONSTRUCTION

A. Nominal 3-inch (76 mm) thick panels in manufacturer’s standard 48-inch (1220 mm) widths.

All panel horizontal and vertical framing members fabricated from minimum 16-gage formed steel with overlapped and welded corners for rigidity.

Top channel is reinforced to support suspension system components. Frame is designed so that full vertical edges of panels are of formed steel and provide concealed protection of the edges of the panel skin.

B. Panel Skin Options (select one):

1. Roll-formed 21-gage steel wrapping around the panel edge. Panel skins shall be lock formed and welded directly to the frame for unitized construction. Acoustical ratings of panels with this construction (select one):

a. 28 STC

b. 50 STC

c. 52 STC

2. Roll-formed 21-gage Micro-perforated steel wrapping around panel edge provided on 50% of panel faces manufactured with sound absorptive backing. Panel skins shall be lock formed and welded directly to the frame for unitized construction. Acoustical ratings of panels with this construction shall be no less than:

a. 45 STC (net with NRC construction)

b. 0.65 NRC with wall covering and upholstery fabric or non-woven needle punch carpet covering

C. Hinges for Panels, Closure Panels, Pass Doors, and Pocket Doors shall be (select one):

1. Full leaf butt hinges, attached directly to panel frame with welded hinge anchor plates within panel to further support hinge mounting to frame. Lifetime warranty on hinges. Hinges mounted into panel edge or vertical astragal are not acceptable.

2. SOSS Invisible laminated hinge with antifriction segments mounted between each heat-treated link. Hinge to be attached directly to panel frame. Welded internal hinge bracket shall support the hinge and allow for adjustment of hinge plates. Concealed hinges mounted into edge or vertical astragal are not acceptable.

D. Panel Trim: No vertical trim required or allowed on edges of panels; minimal groove appearance at panel joints.

E. Panel Weights:

1. 28 STC - 6 lbs./square foot

2. 50 STC - 8 lbs./square foot

3. 52 STC - 11 lbs./square foot

2.4 PANEL FINISHES

A. Panel Face finish shall be (select as required):

1. Reinforced vinyl with woven backing weighing not less than 20 ounces (567 g) per lineal yard.

2. Reinforced heavy-duty vinyl with woven backing weighing not less than 30 ounces (850

g) per lineal yard.

3. Acoustical, non-woven needle punch carpet, with fused fibers to prevent unraveling or fray of material.

4. Wall covering and upholstery fabric with surface treatment to resist stains.

5. Customer’s own material (subject to factory approval).

6. Full height steel markerboard work surface.

7. Full height 1/4-inch (6.35 mm) natural cork tackboard with vinyl or fabric covering.

8. Uncovered for field finishing.

9. Primed for field finishing.

B. Panel Trim: Exposed panel trim of one consistent color from manufacturer’s standard offering (select one):

1. Dark Bronze

2. Smoke Gray

3. Natural Choice

Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.4

Technical Data 10 22 26 (10650) Operable Partitions

ACOUSTI-SEAL® LEGACY® SERIES TECHNICAL DATA

2.5 SOUND SEALS

A. Vertical Interlocking Sound Seals between panels:

Roll-formed astragals, with reversible tongue and groove configuration in each panel edge, for universal panel operation. Rigid plastic astragals or astragals in only one panel edge are not acceptable.

B. Horizontal Top Seals: Continuous contact extruded vinyl bulb shape with pairs of non-contacting vinyl fingers to prevent distortion without the need for mechanically operated parts.

C. Horizontal Bottom Seals (select one):

1. A2 - Automatic operable seals providing nominal 2-inch (51 mm) operating clearance with an operating range of +1/2-inch (13 mm) to –1-1/2 inch (38 mm) which automatically drop as panels are positioned, without the need for tools or cranks.

2. Floating Bottom Seal. Floating operable seals provide nominal 3-1/2 inch (89 mm) operating clearance within operating range of +1/2-inch (15 mm) to –3-inch (76 mm) and shall provide continuous floor contact as panels are positioned with no need for tools or cranks.

a. Carpet glides (carpet flooring)

b. Swivel casters (hard surface flooring)

2.6 SUSPENSION SYSTEM (select one)

A. #14 Suspension System

1. Suspension Tracks: Minimum 7-gage, 0.18-inch (5 mm) roll-formed steel. Track shall be supported by adjustable steel hanger brackets connected to structural support by pairs of 1/2-inch (13 mm) diameter threaded rods. Brackets must support the load bearing surface of the track.

a. Exposed track soffit: Steel, removable for service and maintenance, attached to track bracket without exposed fasteners, and pre-painted off-white.

2. Carriers: All-steel trolleys with steel-tired ball bearing wheels.

3. Warranty period: Ten (10) years.

– OR –

B. #30 Suspension System

1. Suspension Tracks: Track shall be structural aluminum. Track shall be supported by adjustable steel hanger brackets connected to structural support by pairs of 3/8-inch (9.5 mm) diameter threaded rods.

a. Exposed track soffit: Track soffit to be integral to track shape and shall be powder-coated off white paint finish.

Track must accommodate termination of plenum sound barriers on both sides of track for maximum sound control.

2. Carriers: One trolley in alternating panels with 3-inch (76 mm) diameter glass reinforced nylon, all steel precision-ground ball-bearing wheels.

Steel wheeled or reinforced polymer trolleys on aluminum track not permitted. Trolleys shall attach to panels with 1/2-inch (13 mm) diameter pendent bolt mounted to welded steel mounting plate.

3. Warranty period: Two (2) years.

2.7 OPTIONS

A. Single Pass Door:

1. Matching pass door same thickness and appearance as panels. ADA compliant pass door to be trimless and equipped with friction latch and flush pulls for panic operation. No threshold will be permitted.

B. Hardware:

1. Hand pull with push plate.

2. Lever handles both sides of door

3. Automatic door closer.

4. Door viewer.

5. Self-Illuminated exit signs:

a. Chemical exit sign – recess mount C. Work Surfaces:

1. Markerboard: White enamel on steel, bonded to the face of the panel with horizontal trim without exposed fasteners. Trim is not acceptable on vertical edges to provide uninterrupted work surface.

2. Tackboard: Minimum 1/4-inch (6.35mm) natural cork, covered with vinyl or fabric, with horizontal trim without exposed fasteners. Trim is not acceptable on vertical edges.

D. “Presto” Safety Components:

1. Presto Safety Nose (wireless) – High sensitivity pressure leading edge requiring no more than

2.2 lb. of pressure to stop partition movement in case of obstruction. Lead sensors requiring hard wiring through partition system or requiring more than 2.2 lb. of pressure for activation are not acceptable. Sensing edge to be housed in fluid resistant housing and set in snap in channel for easy maintenance and be provided with 4-lead fail-safe wiring.

2. Presto Safety Mats – Located at panel storage area. Personnel sensing switch mat shall activate with the presence of a minimum 22

lb. obstruction in the stack area and prevent panels from stacking until the personnel/

Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com. 5

Technical Data 10 22 26 (10650) Operable Partitions

ACOUSTI-SEAL® LEGACY® SERIES TECHNICAL DATA

ACOUSTI-SEAL® LEGACY®

ELECTRIC (933E) 28 STC 50 STC 52 STC

#14 Bracket Mounted Track 28’-4” (8636 mm)

26’-4” (8026 mm)

18’-4” (5588 mm)

#30 Bracket Mounted Track 12’-4” (3759 mm)

12’-4” (3759 mm)

12’-4” (3759 mm)

STC CONSTRUCTION ANDSTC CONSTRUCTION AND

TRACK SYSTEM HEIGHT LIMITATIONSTRACK SYSTEM HEIGHT LIMITATIONS

obstruction is removed. Mats shall be provided with 4-lead fail-safe wiring.

3. Presto Vision (PIR/Microwave Detector) – Wall or ceiling mounted motion sensors covering the travel area of the automated partition shall automatically stop the movement of the panels in the presence of unauthorized movement or obstruction. Detector can detect motion in an area up to 300 ft. (91M) long by

7.5 ft. (2.3M) wide and 10 ft. (3M) high and be equipped with anti-masking protection.

E. Available Accessories/Options:

1. Pocket Doors: Acousti-Seal Pocket Doors by

Modernfold, Inc., with same construction, finish, and appearance as the adjacent panels.

Equipped with electric interlock system.

2. Finished end caps.

3. Intersecting partition interface.

4. Window frame options:

a. Aluminum window frame, glazed or unglazed

b. Wood window frame, glazed or unglazed

5. Inset window glazing options:

a. 1/4-inch clear tempered glass – aluminum frame or wood frame

b. 1/4-inch low iron tempered glass – aluminum frame or wood frame

c. 1/4-inch Lexan – aluminum frame

d. 1/2-inch clear tempered glass – wood frame

e. 1/2-inch low iron tempered glass – wood frame

f. 1-inch insulated glass – wood frame

6. Resilient Padding – 1/2-inch (13mm) resilient material covered with heavy-duty vinyl.

PART 3 – EXECUTION

3.1 INSTALLATION

A. General: Comply with ASTM E557, operable partition manufacturer’s written installation instructions, Drawings and approved Shop Drawings.

B. Install operable partitions and accessories after other finishing operations, including painting have been completed.

C. Match operable partitions by installing panels from marked packages in numbered sequence indicated on Shop Drawings.

D. Broken, cracked, chipped, deformed or unmatched panels are not acceptable.

3.2 CLEANING AND PROTECTION

A. Clean partition surfaces upon completing installation of operable partitions to remove dust, dirt, adhesives, and other foreign materials according to manufacturer’s written instructions.

B. Provide final protection and maintain conditions in a manner acceptable to the manufacturer and Installer that ensure operable partitions are without damage or deterioration at time of Substantial Completion.

3.3 ADJUSTING

A. Adjust operable partitions to operate smoothly, easily, and quietly, free from binding, warp, excessive deflection, distortion, nonalignment, misplacement, disruption, or malfunction, throughout entire operational range. Lubricate hardware and other moving parts.

3.4 EXAMINATION

A. Examine flooring, structural support, and opening, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of operable partitions. Proceed with installation only after unsatisfactory conditions have been corrected.

3.5 DEMONSTRATION

A. Demonstrate proper operation and maintenance procedures to Owner’s representative.

B. Provide Operation and Maintenance Manual to

Owner’s representative.

Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.6

Technical Data 10 22 26 (10650) Operable Partitions

ACOUSTI-SEAL® LEGACY® SERIES TECHNICAL DATA

STEEL SKIN PANEL CONSTRUCTION

Acousti-Seal® Legacy® Electric Panel Section Frame Details

Acousti-Seal® Legacy® Electric Standard Panel Joint

NON-DISTORTING

BULB-AND-FINGER

ACOUSTICAL SWEEP

FORMED STEEL SKIN

WITH NO SHARP

EDGES WELDED TO

FRAME

.75" (19mm)

SOLID STEEL

TROLLEY MOUNT

INSULATED BOTTOM

SEAL CAVITY WITH

DOUBLE ACOUSTICAL

SEALS

DUAL-DUROMETER

FLOOR SEAL WITH

CONTOUR MATCHING

OUTER SEALS

FLOOR

SELF-CONTAINED,

SERVICEABLE

BOTTOM SEALS

16 GA. FORMED

STEEL BOTTOM

FRAME CHANNEL

DOUBLE

16 GA. STEEL

TOP CHANNEL

WITH HEAVY

STEEL CORNER

REINFORCEMENTS

UNDERSIDE OF

TRACK/SOFFIT

PANEL DETAILS ARE NOT TO SCALE

NOMINAL 21 GA. STEEL

SKINS WITH ACOUSTICAL

BACKER

ROLL-FORMED EDGES

WRAPPED AROUND,

LOCKED AND WELDED

TO VERTICAL FRAME

STEEL DUAL

INTERLOCKING VERTICAL

ASTRAGAL WITH VINYL

ACOUSTICAL GASKET

ROLL-FORMED

STEEL VERTICAL

FRAME CHANNEL

WITH NO SHARP

EDGES

MINIMUM GROOVE

AT PANEL JOINT WITH

NO VERTICAL EDGE TRIM

16 GA. ROLL-FORMED

STEEL VERTICAL

FRAME CHANNEL

ACOUSTICAL

INSULATION

AS-41

Roll-formed skin wraps completely around the edge of vertical 16-gage steel channel and is locked in place, eliminating any sharp edges and creating a unitized panel. The finish material is secured under the steel astragal to prevent peeling.

Model Detail from Website

STEEL BUTT

HINGES ATTACH

DIRECTLY TO

HEAVY STEEL

BACKER PLATES

WELDED TO FRAME

FINISH MATERIAL WRAPPED

AROUND PANEL EDGE AND

CAPTURED BY VERTICAL

ASTRAGAL

16 GA. ROLL-FORMED

STEEL VERTICAL FRAME

CHANNEL WITH NO

SHARP EDGES

ROLL-FORMED EDGES

WRAPPED AROUND,

LOCKED AND WELDED

TO VERTICAL FRAME

AS-42R

Heavy steel hinges are mounted directly to the center of the vertical frame channel, not simply on the outside edge of the panel. Steel plates welded to the back of the channel prevent buckling or bending and provide the strongest hinged connection.

Model Detail from Website

Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com. 7

Technical Data 10 22 26 (10650) Operable Partitions

ACOUSTI-SEAL® LEGACY® SERIES TECHNICAL DATA

SUSPENSION SYSTEM OPTIONS

(1 m m

M

IN

IM

U M

.75" (19 mm)

GUIDE

RAIL

10.25" (260 mm)

SOFFIT

VINYL TOP SEAL

CLG

LINE

FA

B

R

IC

AT

IO

N H

E

IG

H T

AUTOMATIC DROP SEAL

PROVIDES 2" (51 mm)

OPERATING CLEARANCE

(+ .50" TO 1.50") /

(+13 mm TO – 38 mm)

STRUCTURAL

SUPPORT NOT BY

MODERNFOLD

.50" (13 mm) DIA X 9" (229 mm)

LONG HANGER RODS

BY MODERNFOLD

ROLLER CHAIN

HANGER BRACKET

BY MODERNFOLD

STEEL BALLBEARING

TROLLEYS

OFF WHITE

BAKED ENAMEL

SOFFIT TRIM PAN

BY MODERNFOLD

7.50" (191 mm)

BRACKET

5" (127 mm)

GAGE

#14 Track System Bracket Mounted with Automatic Drop Seal

AS-143

Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.8

Technical Data 10 22 26 (10650) Operable Partitions

ACOUSTI-SEAL® LEGACY® SERIES TECHNICAL DATA

SUSPENSION SYSTEM OPTIONS

#14 Track System Bracket Mounted with Floating Seal for Hard Floor

AS-144

Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com. 9

Technical Data 10 22 26 (10650) Operable Partitions

ACOUSTI-SEAL® LEGACY® SERIES TECHNICAL DATA

SUSPENSION SYSTEM OPTIONS

#14 Track System Bracket Mounted with Floating Seal for Carpet Floor

AS-145

Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.10

Technical Data 10 22 26 (10650) Operable Partitions

ACOUSTI-SEAL® LEGACY® SERIES TECHNICAL DATA

SUSPENSION SYSTEM OPTIONS

RECOMMENDED ACCESS

PANEL OPENING

36" (914 mm)10.53"

(267 mm)

1.88" (48 mm)

5" (127 mm)

30" (762 mm)

12" (305 mm)

TRACK

CENTERLINE

#14 Track System Bracket Mounted Top View

#14 Motor TV

Model Detail from Website

RECOMMENDED ACCESS

PANEL OPENING

36" (914 mm)

10.53" (267 mm)

TRACK

CENTERLINE

12" (305 mm)

12" (305 mm)

#14 Track System Bracket Mounted Horizontal View

#14 Motor

HV

Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com. 11

Technical Data 10 22 26 (10650) Operable Partitions

ACOUSTI-SEAL® LEGACY® SERIES TECHNICAL DATA

SUSPENSION SYSTEM OPTIONS

FA

B

R

IC

AT

IO

N H

E

IG

H T

3.50" (89 mm)

2.50" (64 mm)

5.38" (137 mm)

TRACK

STRUCTURAL

SUPPORT NOT

BY MODERNFOLD

CLG

LINE

VINYL TOP SEAL

STEEL

BALLBEARING

TROLLEYS

ROLLER CHAIN

HANGER BRACKET

BY MODERNFOLD

RECOMMENDED

SOUND BAFFLE

NOT BY

MODERNFOLD

OR DISTRIBUTOR

GUIDE RAIL

.38" (10 mm) DIA X 9" (229 mm)

LONG HANGER RODS

BY MODERNFOLD

m m

M

IN

IM

U

M

GAGE

BRACKET

.75" (19 mm)

#30 Track System Standard Spacing

AS-119

Model Detail from Website

FA

B

R

IC

AT

IO

N H

E

IG

H T

STRUCTURAL

SUPPORT NOT

BY MODERNFOLD

RECOMMENDED

SOUND BAFFLE

NOT BY

MODERNFOLD

OR DISTRIBUTOR

CLG

LINE

VINYL

TOP SEAL

GUIDE RAIL

STEEL

BALLBEARING

TROLLEYS

ROLLER CHAIN

HANGER

BRACKET BY

MODERNFOLD

5.50" (140 mm)

4.50" (114 mm)

GAGE

5.38" (137 mm)

TRACK

.38" (10 mm) DIA × 9" (229 mm)

LONG HANGER

RODS BY

MODERNFOLD

m m

M

IN

IM

U

M

.75" (19 mm)

BRACKET

#30 Track System Optional Wider Spacing

AS-120

Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.12

Technical Data 10 22 26 (10650) Operable Partitions

ACOUSTI-SEAL® LEGACY® SERIES TECHNICAL DATA

SUSPENSION SYSTEM OPTIONS

RECOMMENDED ACCESS

PANEL OPENING

1.88" (48 mm)

5.00" (127 mm)

30.00" (762 mm)

36.00" (914 mm)

10.56" (268 mm)

12.00" (305 mm)

TRACK

CENTERLINE

#30 Track System Motor Top View

#30 Motor TV

Model Detail from Website

RECOMMENDED ACCESS

PANEL OPENING

36.00" (914 mm)

10.56" (268 mm)

12.00" (305 mm)

12.00" (305 mm)

TRACK

CENTERLINE

#30 Track System Motor Horizontal View

#30 Motor

HV

Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com. 13

Technical Data 10 22 26 (10650) Operable Partitions

ACOUSTI-SEAL® LEGACY® SERIES TECHNICAL DATA

PANEL, WORK SURFACE, AND PASS DOOR OPTIONS

SELF-LUMINOUS EXIT SIGNS

(RECESSED MOUNTED)

NO VERTICAL TRIM

ON PANEL (TYPICAL)

"H" TYPE PASS

DOOR

SELF-LUMINOUS

EXIT SIGN (OPTIONAL

LOCATION)

RECESSED HAND PULL WITH

FRICTION LATCH (ADA COMPLIANT)

RECESSED ERASER

HOLDER

6' -8 m m

O R

7' -0 m m

VA

RI

A

BL

E

'-0 m m

MARKERBOARD OR TACKBOARD

(NO VERTICAL TRIM REQUIRED)

Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.14

Technical Data 10 22 26 (10650) Operable Partitions

ACOUSTI-SEAL® LEGACY® SERIES TECHNICAL DATA

PANEL, WORK SURFACE, AND PASS DOOR OPTIONS

FLOOR SEAL OPTIONS

FLOOR

2"

(51 mm)

AUTOMATIC DROP SEAL

PROVIDES 2" (51 mm)

OPERATING CLEARANCE

(+ .50" TO 1.50") /

(+13 mm TO – 38 mm)

2-inch Automatic Seal

AS-12C

Model Detail from Website

Floating Seal - Hard Floors

AS-15

Model Detail from Website

Floating Seal - Carpet

AS-17

Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com. 15

Technical Data 10 22 26 (10650) Operable Partitions

ACOUSTI-SEAL® LEGACY® SERIES TECHNICAL DATA

POCKET ENCLOSURE AND STACKING OPTIONS

PANEL CROSS SECTIONS

STACK DEPTH

NO. OF PANELS

× 3.75" (95 mm) + 9.50" (241 mm)

/2

P A

N E

L W

ID

TH

P

LU

S

(1 m m

M

IN

/2

P A

N E

L W

ID

TH

P

LU

S

(1 m m

M

IN

OPTIONAL

POCKET

SIDE R

SIDE L

FLOOR GUIDE

IN STACK

AREA ONLY

(SEE AS-40)

Legacy® Electric Standard Stack

FINISH SAME

AS PANELS

CAULKING BETWEEN

JAMB AND WALL

3" (76 mm)

1.25" (32 mm)

ALIGNMENT FORK

(AS REQUIRED)

BLOCKING

BY OTHERS

Nominal Fixed Jamb

AS-21C

Model Detail from Website

3" (76 mm)

4" (102 mm) TO 12" (305 mm)

ALIGNMENT FORK

(AS REQUIRED)

FINISH SAME

AS PANELS

CAULKING BETWEEN

JAMB AND WALL

BLOCKING

BY OTHERS

Variable Fixed Jamb

AS-22C

Model Detail from Website

STACK DEPTH

PLUS 6" (152 mm)

MIN.

INSTALLATION WIDTH

(TO FACE OF POCKET)

POCKET DOOR

INTERLOCK SWITCH

(2 REQ'D)

TYPE II

POCKET DOOR

SIDE R

SIDE L

10" (254 mm)

HOLD FLOOR

GUIDE IN STACK

AREA ONLY

(SEE AS-40B)

STACK DEPTH

NO. OF PANELS

× 3.75" (95 mm) + 8.50" (216 mm)

1/

PA

N

EL

W

ID

TH

PL

U

S 8" m m

M

IN

1/

PA

N

EL

W

ID

TH

PL

U

S 8" m m

M

IN

Legacy® Electric Remote Stack

Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.16

Technical Data 10 22 26 (10650) Operable Partitions

ACOUSTI-SEAL® LEGACY® SERIES TECHNICAL DATA

FINISH SAME

AS PANELS

CAULKING

BETWEEN

JAMB AND WALL

SIDE SEAL

RETAINER

9" (229 mm)

JAMB

JAMB

REFERENCE

.2

(8 m m

Side Jamb Steel Skin

AS-38R

Model Detail from Website

VINYL SEAL AND

STEEL ASTRAGAL

VINYL BULB

SEAL

m m

R

E F

Bulb Seal and Intersection

AS-49

Model Detail from Website

Panel Splice Steel Skin

AS-19

Model Detail from

PANEL CROSS SECTIONS

Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com. 17

Technical Data 10 22 26 (10650) Operable Partitions

ACOUSTI-SEAL® LEGACY® SERIES TECHNICAL DATA

VINYL SEAL

.2

(1 m m

END CAP

JAMB

REF.

ASSEMBLY SHIPS

LOOSE FOR FIELD

ATTACHMENT

FOOT BOLT

POCKET DOOR

Side Seal Remote Stack

AS-58RA

Model Detail from Website

2.38" (60 mm)

RECESS

1.19" (30 mm)

1.

(4 m m

R

EC

ES

S

.1 9"

(5 m m

1.5" (38 mm)

GROUT BY OTHERS

FINISHED FLOOR1"

(25 mm)

Remote Stack Floor Guide

AS-40B

Model Detail from Website

FLOOR TRACK

GROUT AS REQUIRED

#8 - 18 × 1.25

FLAT HEAD SCREW

BY MODERNFOLD

LEAD EXPANSION ANCHOR

BY MODERNFOLD

2" (5 m m

2" (51 mm)

Standard Floor Guide

AS-40

Model Detail from

Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com.18

Technical Data 10 22 26 (10650) Operable Partitions

ACOUSTI-SEAL® LEGACY® SERIES TECHNICAL DATA

SOSS Hinged Panel Joint

AS-42RS

Model Detail from Website

ROLL-FORMED EDGES

WRAPPED AROUND,

LOCKED AND WELDED

TO VERTICAL FRAME

Steel Panel Construction

Please contact your local Modernfold distributor for further assistance, or visit our website at www.modernfold.com. 19

Technical Data 10 22 26 (10650) Operable Partitions

ACOUSTI-SEAL® LEGACY® SERIES TECHNICAL DATA

NON-STEEL SKIN PANEL CONSTRUCTION

Form No. 2555 1/22

215 West New Road Greenfield, IN 46140

Tel: 800.869.9685

Email: info@modernfold.com Website: www.modernfold.com

Acousti-Seal® Legacy® Electric (933E) Technical Data 10 22 26 (10650) Operable Partitions

Tek-Wall Ridge 002 Tonic 111873-679 x x

307" VERIFIED

x

CARPET TILE

(0.149")

16 7/8"

8"

8"

14 1/4"

11 7/8"

OVERLAY ON MOST CURRENT M101

ENTIRE SUPPORT STRUCTURE

WILL BE BELOW DUCTWORK

OLD 36X18 TO BE

REMOVED AND

REPLACED BY (2) 24X12

AS SHOWN ABOVE

NEW 24X12 DUCTS WILL

BE ROUTED ABOVE

SUPPORT STRUCTURE

(ON RIGHT): PHOTO IN LINE WITH DOOR

TRACK FACING SOUTH

(ABOVE): PHOTO IN LINE WITH DOOR

TRACK FACING NORTH

File details come from the government source that posted it. Updated .