About this file
This document contains the specifications for a Breathing Air Compressor required by the 914th contracting office at Niagara Falls Air Reserve Station (NFARS) in New York. The key requirements are for a Bauer Model Legacy 18-E3 compressor or equivalent that is compatible with the existing Air Charge Station, has a minimum 18 CFM/510L/Min fill speed, 6000 psig 4 stage compressor, 15 HP motor, CO monitor/sensor, maximum size of 50" x 40" x 75", and must be electric powered. The contractor will be responsible for installing the system.
This is a Sources Sought Inquiry issued by the Department of the Air Force Reserve Command to identify potential sources, including small businesses, that can provide the specified Breathing Air Compressor. Respondents are requested to provide information such as company details, small business category, and any recommendations or concerns. This RFI/SSI is for informational and planning purposes only, with no funds available to fund the requested information. Any updates will be posted on sam.gov, and oral submissions will not be accepted.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sources Sought - Breathing Air Compressor.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Breathing Air Compressor Requirement Specifications
Quantity 1 - Breathing Air Compressor
Bauer Model Legacy 18-E3 with CO monitor or equivalent
Minimum Specifications:
System MUST be compatible with existing Air Charge Station
Station Model: Scott Safety Revolve Air Charge Station Model #AB110-2300-4
Breathing Air Compressor Air Purification System (CGA Grade E Air)
Compressor Minimum:
Capable of 18 CFM/510L/Min fill speed
6000 psig
4 Stage compressor
15 HP motor minimum
CO Monitor/sensor
Maximum size 50” x 40” x 75”
Electric powered (no gas-powered compressors)
CONTRACTOR TO INSTALL SYSTEM
File details come from the government source that posted it. Updated .