This is a bridge replacement design and engineering document prepared for the North Carolina Department of Public Safety, Division of Emergency Management (NCEM) in partnership with Buncombe County, detailing structural plans for the reconstruction of a private bridge and roadway approaches on Site# 001-01-00403 at Ivey Baptist Road over Ivy Creek in Buncombe County. The project involves the replacement of an existing bridge structure that was damaged, with construction designed to meet AASHTO LRFD specifications and accommodate HS-20 live loads with emergency vehicle (EV3) load ratings exceeding 1.0. The proposed bridge features a total length of 132 feet 6 inches, consisting of three spans (131 feet 2 inches, 150 feet 1 inch, and 151 feet 2 inches), and includes a bridge opening of 1,308 square feet compared to the existing 1,020 square feet. The structure utilizes prestressed concrete cored slab units measuring 3 feet by 1 foot 9 inches supported by steel H-piles (HP 12 x 53 and HP 14 x 73) with elastomeric bearings. Bill of material quantities include 2,331 linear feet of steel piles, 804 prestressed concrete cored slabs, 1,408 cubic yards of Class A concrete, 260.5 linear feet of safety rail, and temporary access causeway construction and removal. The design was completed by Emily Murray, licensed professional engineer (NC License No. 025516), with plans dated September 25, 2025, and revised on November 5, 2025.
The document specifies construction requirements including the removal of existing structure containing lead-based paint, erosion control measures with Class II rip rap placement, temporary causeway construction and maintenance for construction access, bridge safety rail installation, and falsework and formwork provisions. Project maintenance protocols recommend certified bridge inspections every five years for the first ten years of operation, every four years for years ten to twenty, every three years for years twenty to thirty, and every two years thereafter. The bridge is designed to prevent ponding and erosion through proper drainage, with structural maintenance including crack sealing, rebar exposure repair, fastener tightening, and debris removal from the deck and underlying areas. Funding for this project is provided through FEMA Public Assistance under the Stafford Act (42 U.S.C. 5173, 5189f, 5170b) as part of North Carolina's hazard event declaration response, with NCEM acting as the Recipient and disbursing funds to approved subrecipients including state and local governments and private nonprofit organizations.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Bridge Contract No. 4
Site# 001-01-00403 Ivey Baptist Rd over Ivy Creek in Buncombe County
R = 350
Tc = 17.50
Lc = 34.98
D = 16°22'12.8"
Δc = 05°43'31.8" (RT) PIc 11+43.92
R = 80 Tc = 30.88 Lc = 58.94
D = 71°37'11.0" �c = 42°12'34.8" (RT)
Plc 13+36.48
CURVE DATA -L-
CURVE DATA -L-
PLAN
ELEVATION ALONG -L-
END BENT 1 BENT 1 BENT 2 END BENT 2
GRADE DATA -L-
V.C. = 60.00'
P.V.I. EL. 2043.87
P.V.I. STA. 11+44.00 -L-
GRADE DATA -L-
V.C. = 30.00'
P.V.I. EL. 2048.93
P.V.I. STA. 13+60.00 -L-
(-)2.7500%(+)2.3426%
(+)2.3426% (-)17.4524%
132'-6" TOTAL LENGTH OF BRIDGE (FILL FACE @ E.B. 1 TO FILL FACE @ E.B. 2)
(SPAN C)
"4 151'-2
(SPAN B)
"2 150'-1
(SPAN A)
"4 131'-2
BRIDGE I.D.
STA. 12+35.00 -L-
STA. 11+68.75 -L-
FILL FACE @ END BENT 1
W.P. #1
STA. 11+99.94 -L-
BENT 1 CONTROL LINE
W.P. #2
STA. 12+50.06 -L-
BENT 2 CONTROL LINE
W.P. #3
STA. 13+01.25 -L-
FILL FACE @ END BENT 2
W.P. #4
13+0012+00 12+5011+50
8/5/2025
NWSEL = 2031.0
GROUND LINE
APROX. EXISTING
FIX. FIX. FIX.
FIX. FIX. FIX.
SPAN A SPAN B SPAN C
IV
Y C
R E
E K
EL. 2038.0 ±
EL. 2033.0 ±
EL. 2031.0 ± EL. 2029.0 ±
EL. 2031.0 ±
EL. 2037.0 ±
EL. 2047.0 ±
-L-
BUNCOMBE
IVY CREEK IN WEAVERVILLE
ROAD (SR-2154) OVER
BRIDGE AT 29 IVEY BAPTIST
GENERAL DRAWING
12+35.00 -L-
011.01.00403
M. HOGAN 09/25
STEEL PILES
HP 12 X 53
STEEL PILES
HP 12 X 53
STEEL PILES
HP 14 X 73
STEEL PILES
HP 14 X 73
S72°06'13.2"E
PT STA. 11+61.39 -L- PC STA. 13+05.60 -L-
315'-0
335'-0
EL. 2045.39
LOW CHORD
EL. 2042.38
LOW CHORD
(TYP.)
CLASS II RIP RAP
/2
/2
NO. NO.BY: BY:DATE: DATE:
REVISIONS SHEET NO.
TOTAL
SHEETS
COUNTY
SITE NO.
11/5/2025 emily.murray R:\PROJECTS\Engineering Projects\1203695.000 Grow NC NCEM Private Roads and Bridges\6.0 Assignments\29 Ivey Baptist Rd\Structures\2.4 Final Structure Plans\IveyBabtistRd_gd.dgn
STATION:
SIGNATURES COMPLETED
FINAL UNLESS ALL
DOCUMENT NOT CONSIDEREDDRAWN BY :
CHECKED BY :
DATE :
DATE :
DATE :DESIGN ENGINEER OF RECORD:
CAUSEWAY I
ACCESS
TEMPORARY
E. MURRAY 09/25
FILL FACE @ END BENT 1
STA. 11+68.75 -L-
EL. 2044.50
EL. 2033.0 ±
FILL FACE @ END BENT 2
STA. 13+01.25 -L-
2047.55
RIP RAP (TYP.)
CLASS II
2'-0" THICK
FEMA 100 YR EL = 2045.16
PRELIMINARY
AND PROFILE SHEET)
(SEE CAUSEWAY PLAN
CAUSEWAY II
TEMPORARY ACCESS
FINAL
PROPOSED BRIDGE OPENING = 1308 SF
EXISTING BRIDGE OPENING = 1020 SF
HYDRAULIC DATA
S-1
S-1
EL 2032.0
ACCESS CAUSEWAY I
TEMPORARY
SEAL
025516
NO
RTH CAROLINA
PR
OF
ESSIONAL
ENGINEER
E
M
ILY E. MURRA
Y
Docusign Envelope ID: D2672709-1AEC-4D5B-9582-43A21CBC0530
11/5/2025
BUNCOMBE
IVY CREEK IN WEAVERVILLE
ROAD (SR-2154) OVER
BRIDGE AT 29 IVEY BAPTIST
GENERAL DRAWING
12+35.00 -L-
011.01.00403
NO. NO.BY: BY:DATE: DATE:
REVISIONS SHEET NO.
TOTAL
SHEETS
COUNTY
SITE NO.
STATION:
SIGNATURES COMPLETED
FINAL UNLESS ALL
DOCUMENT NOT CONSIDERED
M. HOGAN 09/25DRAWN BY :
CHECKED BY :
DATE :
DATE :
DATE :DESIGN ENGINEER OF RECORD:
E. MURRAY 09/25
FOR PILES, SEE SECTION 450 OF THE STANDARD SPECIFICATIONS.
ON PLANS.
TO THE GRADE OF THE BRIDGE DECK, UNLESS OTHERWISE SHOWN
METAL STANDARDS FOR THE BRIDGE RAIL SHALL BE SET NORMAL
LEGS ON ADJOINING PIECES.
THE ENDS OF THE SUPPORTING WIRES SHALL BE LAPPED TO LOCK
PLACED IN CONTINUOUS LINES, THEY SHALL BE SO PLACED THAT
WHERE INDICATED ON THE PLANS. WHEN BAR SUPPORT PIECES ARE
WIRE BAR SUPPORTS SHALL BE PROVIDED FOR REINFORCING STEEL
INDICATED ON PLANS.
DETAILS ARE TO CENTERS OF BARS OR ARE OUT TO OUT AS
UNLESS OTHERWISE INDICATED IN THE PLANS. DIMENSIONS ON BAR
RELATIVE TO PLACEMENT OF REINFORCING ARE TO CENTERS OF BARS
ALL REINFORCING STEEL SHALL BE DEFORMED. DIMENSIONS
SHOWN ON PLANS.
THE BRIDGE SHALL BE BUILT ON THE GRADE OR VERTICAL CURVE
".4
ON STRUCTURES SHALL BE CHAMFERED
UNLESS OTHERWISE NOTED ON THE PLANS, ALL EXPOSED CORNERS
SUPERSTRUCTURES.
EXCEPTION THAT CLASS AA CONCRETE SHALL BE USED IN BRIDGE
SHALL BE USED FOR ALL PORTIONS OF ALL STRUCTURES WITH THE
UNLESS OTHERWISE REQUIRED ON PLANS, CLASS A CONCRETE
TRANSPORTATION.
ROADS AND STRUCTURES" OF THE N. C. DEPARTMENT OF
IN ACCORDANCE WITH THE 2024 "STANDARD SPECIFICATIONS FOR
SPECIAL PROVISIONS, ALL MATERIAL AND WORKMANSHIP SHALL BE
EXCEPT AS MAY OTHERWISE BE SPECIFIED ON PLANS OR IN THE
"REMOVAL OF EXISTING STRUCTURE."
LEAD BASED PAINT SHALL BE INCLUDED IN THE BID PRICE FOR
REGULATIONS PERTAINING TO HANDLING OF MATERIALS CONTAINING
RESULTING FROM COMPLIANCE WITH APPLICABLE STATE OR FEDERAL
ARTICLE 107-1 OF THE STANDARD SPECIFICATIONS. ANY COSTS
CONTAINS LEAD, THE CONTRACTOR'S ATTENTION IS DIRECTED TO
INASMUCH AS THE PAINT SYSTEM ON THE EXISTING STRUCTURAL STEEL
PREVENTS DEBRIS FROM FALLING INTO THE WATER.
PROPOSED BRIDGE SHALL BE PERFORMED IN A MANNER THAT
REMOVAL OF THE EXISTING BRIDGE REMNANTS AND WORK ON THE
EXISTING BRIDGE REMNANTS SHALL BE REMOVED.
ON ROADWAY PLANS.
ASPHALT WEARING SURFACE IS INCLUDED IN ROADWAY QUANTITY
CONSTRUCTION, MAINTENANCE AND REMOVAL OF TEMPORARY ACCESS.
PLACED AS RIP RAP PROTECTION. SEE SPECIAL PROVISIONS FOR
CAUSEWAYS, THE CLASS II RIP RAP USED IN THE CAUSEWAYS MAY BE
AT THE CONTRACTOR'S OPTION, AND UPON REMOVAL OF THE
FOR EROSION CONTROL PLANS, SEE EROSION CONTROL PLANS.
FOR BRIDGE SAFETY RAIL, SEE SPECIAL PROVISIONS.
ACCESS, SEE SPECIAL PROVISIONS.
FOR CONSTRUCTION, MAINTENANCE, AND REMOVAL OF TEMPORARY
FOR GROUT FOR STRUCTURES, SEE SPECIAL PROVISIONS.
FOR CRANE SAFETY, SEE SPECIAL PROVISIONS.
FOR FALSEWORK AND FORMWORK, SEE SPECIAL PROVISIONS.
AASHTO LRFD DESIGN SPECIFICATIONS EXCEPT AS NOTED.
THIS BRIDGE HAS BEEN DESIGNED IN ACCORDANCE WITH
EMERGENCY VEHICLE (WEIGHT = 86 KIPS).
THE BRIDGE IS LOAD RATED OVER 1.0 FOR EV3 THEORETICAL
ASSUMED LIVE LOAD = HS-20.
NOTES
LOCATION SKETCH
REINFORCING
STEEL
HP 12 X 53
STEEL PILES
ELASTOMERIC
BEARINGS
SUPERSTRUCTURE
TOTAL
END BENT NO. 1
END BENT NO. 2
BENT NO. 1
LBS. NO. LUMP SUM
LUMP SUM
LUMP SUM
TOTAL BILL OF MATERIAL
LIN.FT.LUMP SUM
LUMP SUM
NO. LIN.FT.
GALVANIZED
HP 14 X 73
STEEL PILES
TONS
RIP RAP
CLASS II
(2'-0'' THICK)
NO. LIN.FT.
3'-0'' X 1'-9''
PRESTRESSED
CONCRETE
CORED
SLABS
BENT NO. 2
CAUSEWAY I
ACCESS
OF TEMPORARY
AND REMOVAL
MAINTENANCE
CONSTRUCTION
CLASS A
CONCRETE
CU. YDS.
GEOTEXILE
FOR DRAINAGE
2,331
5.1
5.1
15 650
15 65051.4 1408 2208 243
LUMP SUM
LUMP SUM
REMOVAL OF
EXISTING
STRUCTURE
1,019
1,019
2,373
6,742
19.9
21.3
IN SOIL
EXCAVATION
PILE
IN SOIL
NOT
EXCAVATION
PILE
SAFETY
RAIL
LIN.FT.
BRIDGE
260.5
260.5
SQ.YDS.
LIN.FT. LIN.FT.
120.0
20.0
40.0
40.0
20.0
208.0
40.0
56.0
68.0
44.0
LOOKING UP STREAM LOOKING DOWNSTREAM
LOOKING WEST AT END BENT 1 LOOKING EAST FROM END BENT 1 CROSSING BY PROPERTY OWNER
LOOKING EAST AT TEMP0RARY
NORTH CAROLINA
OFFICE OF EMERGENCY MANAGEMENT
SCHEDULE AND INSPECT EVERY 2 YEARS THEREAFTER.
IF DETERIORATION IS NOTED IN INSPECTIONS, ACCELERATE
BRIDGE INSPECTIONS.
REPAIR ANY PRIORITY MAINTENANCE ITEMS NOTED DURING
INSPECT EVERY 2 YEARS YEARS 30+:
INSPECT EVERY 3 YEARS YEARS 20-30:
INSPECT EVERY 4 YEARS YEARS 10-20:
INSPECT EVERY 5 YEARS YEARS 0-10:
INSPECTOR IS RECOMMENDED ON THE FOLLOWING SCHEDULE:
BRIDGE INSPECTION PERFORMED BY A CERTIFIED BRIDGE
RECOMMENDED INSPECTION AND MAINTENANCE
SLAB UNITS.
ANY MILLING ASSOCIATED WITH REPAVING DOES NOT DAMAGE CORED
MAINTAIN ASPHALT WEARING SURFACE IN GOOD CONDITION ENSURING
ON BRIDGE DECK TAKING CARE NOT TO DAMAGE THE CORED SLAB UNITS.
SPALLS WHERE REBAR IS EXPOSED, MILLING AND REPLACING ASPHALT
BOLTS AND FASTENERS, SEALING CRACKS IN CONCRETE, REPAIRING
STRUCTURAL MAINTENANCE SHOULD INCLUDE TIGHTENING LOOSE
THE BRIDGE TO PREVENT PONDING AND EROSION.
REMOVE DEBRIS AND SEDIMENT FROM THE DECK AND UNDERNEATH
DAMAGE OR DETERIORATION OF SAFETY RAIL.
SCOURING AROUND ABUTMENTS AND PIERS, DECK SURFACE WEAR,
IN CONCRETE OR STEEL COMPONENTS, SIGNS OF EROSION OR
OBSERVE BETWEEN INSPECTIONS FOR CRACKS RUST OR SPALLING
S-3
N
ORTH CAROLINA
P R
OF
ESSIONAL
NGINEER
ILY E. MURRA
Y
CAUSEWAY II
ACCESS
OF TEMPORARY
AND REMOVAL
MAINTENANCE
CONSTRUCTION
LUMP SUM
LUMP SUM
TO RESIDENCES
TO
IVEY BAPTIST RD.
IV
E
Y C
R E
E
KPROPOSED
BRIDGE ID STA.
12+35.00 -L-
EXISTING BRIDGE
PRIOR TO
HURRICANE
HELENE
PROPOSED
TEMPORARY
ACCESS
CAUSEWAY II
EXISTING
ACCESS
DRIVE
PROPOSED TEMPORARY
ACCESS CAUSEWAY I
90° SKEW
POST-TENSIONED STRAND OF CORED SLABS
GROUTED RECESS AT END OF
½
STRAND VISE
TRANSVERSE STRAND
HOLE FOR
B B ¼'' ¼''
⅝'' X 5'' X 5'' }
WITH GROUT
FILL RECESS
CORED SLAB
OF EXTERIOR
OUTSIDE FACE
NON-CORROSIVE PIPE.
SHEATHED WITH A
POST-TENSIONING STRAND
SECTION B-BELEVATION VIEW
¼
5¼''
4" 4"
8"
2¾" @ { BRG.)
GRADE PT.
2¾" @ { BRG.
ROADWAY PLANS)
SURFACE (SEE
ASPHALT WEARING
0.02
15'-0"
12'-6" (CLEAR ROADWAY)
2¾" @ { BRG.
7'-6"
5 PRESTRESSED CONCRETE CORED SLAB UNITS = 15'-0"
7'-6"
0.02
-L-
"36'-"36'-
WHEEL GUARD (TYP.)
4" X 6" TIMBER
IN 2½" ~ HOLE
POST-TENSIONING STRAND
0.6" ~ L.R. TRANSVERSE
3'-0"
HALF SECTION
AT INTERMEDIATE DIAPHRAGMS
HALF SECTION
THROUGH VOIDS
DEBONDING LEGEND
CHECKED BY :
DATE :
DATE :
ASSEMBLED BY :
DRAWN BY : DGE 5/09
NO. NO.BY: BY:DATE: DATE:
REVISIONS SHEET NO.
TOTAL
SHEETS
STATION:
COUNTY
PROJECT NO.
END ELEVATION
SHEAR KEY DETAIL
OF EXTERIOR CORED SLABS.
NOTE: OMIT SHEAR KEY ON OUTSIDE FACE
CORED SLAB UNIT
PRESTRESSED CONCRETE
3'-0'' X 1'-9''
SHEET 1 OF 4
SEE STANDARD SPECIFICATIONS, ARTICLE 1078-7.
DISTANCE OF 2'-0" FROM END OF CORED SLAB UNIT.
BOND SHALL BE BROKEN ON THESE STRANDS FOR A
SEE STANDARD SPECIFICATIONS, ARTICLE 1078-7.
DISTANCE OF 6'-0" FROM END OF CORED SLAB UNIT.
BOND SHALL BE BROKEN ON THESE STRANDS FOR A
UNIT SIMILAR EXCEPT SHEAR KEY LOCATION.
INTERIOR SLAB UNIT SHOWN-EXTERIOR SLAB
(STRAND LAYOUT NOT SHOWN.)
AND LOCATION OF DOWEL HOLES.
SHOWING PLACEMENT OF DOUBLE STIRRUPS
3'' 4''4'' 3''11'' 11''
#4 S2
½
3'' 3''
10'' 1'-4''
1'-6''
3'-0''
1'-6''
10''
#4 ``B''
7'' 7''
½
3'' 4''4'' 3''11'' 11''
#4 S2
½
10'' 1'-4''
1'-6''
3'-0''
1'-6''
10''
#4 ``B''
@ 2" CTS.
2 SPA.
@ 2" CTS.
2 SPA.
@ 2" CTS.
4 SPA.
3'' 3''
@ 2" CTS.
2 SPA.
@ 2" CTS.
2 SPA.
7'' 7''
@ 2" CTS.
4 SPA.
½
FIXED END FIXED ENDFIXED END
SPECIFICATIONS, ARTICLE 1078-7.
AT NO ADDITIONAL COST. SEE STANDARD
BE DEBONDED FOR THE FULL LENGTH OF THE UNIT
IN THE CORED SLAB UNIT, THE STRANDS SHALL
FABRICATOR CHOOSES TO INCLUDE THESE STRANDS
THESE STRANDS ARE NOT REQUIRED. IF THE
OPTIONAL FULL LENGTH DEBONDED STRANDS.
CHECKED BY : BCH 6/09
011.01.00403
BUNCOMBE
12+35.00 -L-
S-4
E. E. MURRAY
A. CHAND
9/25 9/25
6"
À BEARING
& #6 DOWELS
2" ~ BACKER ROD
GROUT
SECTION AT END BENT SECTION AT BENT
SURFACE
WEARING
ASPHALT
SURFACE
WEARING
ASPHALT
BEARING PAD
ELASTOMERIC
BEARING PAD
ELASTOMERIC
FOR DETAILS
SEE ``BENT'' SHEETS
SHEETS FOR DETAILS
SEE ``END BENT''
& #6 DOWELS
À BEARING
AT BENT
{ JT.
BEARING PAD
ELASTOMERIC
" 2
" 2
TYPICAL SECTION
½
½
½
½
C
L . 1 C
L
#5 S1
#5 S1
#5 S1
#5 S1
3'-0"
1'-6" 1'-6"
8½" 9½" 9½" 8½"
1'-2" 4" 4" 1'-2"
3"3"
½
¾"
¾
⅜
⅜"
#4 ``B''
VOIDS
8" OR 12" ~
6"
" 1
1'-0"
6"
" 1
VOIDS
8" OR 12" ~
VOIDS
8" OR 12" ~
1½" JT.
DOWEL HOLES
INTERIOR SLAB SECTION.)
(FOR PRESTRESSED STRAND LAYOUT, SEE
(9 STRANDS REQUIRED)
(30' UNIT)
INTERIOR SLAB SECTION
EXT. SLAB SECTION
RELAXATION STRAND LAYOUT
(19 STRANDS REQUIRED)
(50' UNIT)
INTERIOR SLAB SECTION
THREADED INSERT DETAIL
CONTRACTOR.
DETERMINED BY
RECESSED ⅜". SIZE TO BE
EXTERIOR UNIT AND
CAST IN OUTSIDE FACE OF
PERMITTED THREADED INSERT
SIGNATURES COMPLETED
FINAL UNLESS ALL
DOCUMENT NOT CONSIDERED
REV. 5/23 BNB/AAI
REV. 8/14 MAA/TMG
430-6 OF THE STANDARD SPECIFICATIONS.
STRANDS HAVE BEEN TENSIONED AS PER SECTION
ALL ERECTION HAS BEEN COMPLETED AND TRANSVERSE
SHEAR KEYS TO BE FILLED WITH GROUT AFTER
GUARDRAIL (TYP.)
STEEL "W" BEAM
UNIT
PLAN OF
SHOWN ON
SPA. AS
STEEL POST
W6 X 20
¾
B R
G
(T Y
P
TO TOP OF RAIL AT ALL LOCATIONS.
3'-0" MINIMUM HEIGHT FROM THE TOP OF ASPHALT WEARING SURFACE
VARIES DUE TO THE CAMBER IN THE CORED SLAB UNITS. MAINTAIN
THICKNESS IS SHOWN. THE ASPHALT WEARING SURFACE THICKNESS
* -THE MAXIMUM BRIDGE SAFETY RAIL HEIGHT AND ASPHALT
3''3''
#4 B1
3'' 3''
10''
3'-0''
VOID
#4 S2
1'-4"
ANCHOR BOLTS
4- ⅞" ~
ASSEMBLY
ANCHOR
À POST
½
½
½
VOID
CONST. JT.
8½''
"31'- "31'-
10''
½
½
NORTH CAROLINA
OFFICE OF EMERGENCY MANAGEMENT
NC License No. F-0765 Tel. 919-854-0344 Fax. 919-854-0355 Raleigh, NC 27607 5430 Wade Park Blvd., Suite 410
NO
RTH CAROLINA
PR
OF
ESSIONAL
ENGINEER
ILY E. MURRA
Y
1½" OPENING
2" ~ BACKER ROD
GROUT