This document is a Limited Asbestos Survey report for Building 2011 at Fort Bliss, Texas, conducted by AnE Consulting, Inc. on August 18, 2016, for Pride Industries. The survey identified asbestos-containing materials (ACMs) in the building's flooring, specifically 12" white vinyl floor tiles with black mastic. Laboratory analysis confirmed 6% chrysotile asbestos content in the floor tile and mastic, which was observed to be in good condition and classified as non-friable.

The report recommends that if planned renovation or demolition activities will disturb the identified ACM, the materials must be abated by a licensed/accredited abatement contractor in accordance with Federal, State, and Local regulations. A mandatory 10-day notification is required prior to abatement. The estimated quantity of material to be replaced is 450 square feet. The survey was conducted in compliance with national environmental and safety standards, including NESHAP, AHERA, and ASHARA, to ensure proper identification and handling of potential asbestos-containing materials.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Limited Asbestos Survey at Building 2011

Fort Bliss, Texas

Prepared for:

PRIDE INDUSTRIES

P. 0. Box 31310 El Paso, Texas 79931

Prepared by:

.. ca,islJLTIJ"6, IJolC, 912 Texas Ave. Suite C El Paso, Texas 79901

Jose Moriel, Asb s Building Inspector TDSHS #60-3220, Expires 03/05/2017

Date of Inspection

August 18, 2016

August 22, 2016

PRIDE INDUSTRIES

Attn: Victor Duenas P. 0. Box 31310 El Paso, Texas 79931

RE: Limited Asbestos Survey at Building 2011 Fort Bliss, Texas

Dear Mr. Duenas, On August 18, 2016, AnE Consulting, Inc., conducted a limited asbestos survey of the structure at the above-referenced facility. The inspection report is attached.

We appreciate the opportunity to be of service to you. Please contact us with questions or comments, or if we may be of further assistance.

Sincerely, AnE Consulting, Inc.

Asbestos Consulting Agency TDSHS License #10-0441, expires 02/01/2017

Asbestos ilding Inspector TDSHS License #60-3220, Expires 03/05/2017

Enclosures: Asbestos Survey Report Laboratory reports with chain of custody documentation Texas asbestos licenses

AnE Consulting, Inc. • 912 Texas, Suite C • El Paso, Texas • 79901 +1915 532-3788Voice • +1915 532-3789 Fax• aneconsulting@att.net

V COMSILTDI&. l'IC, Purpose

The structure is located at Building 2011, Fort Bliss, Texas. Mr. Victor Duenas, of Pride Industries, requested that AnE Consulting, Inc. (AnE) conduct a limited survey for asbestos containing materials (ACMs) associated with the unit floor. This survey is intended for the identification and locations of Asbestos Containing Materials and may be utilized for future renovation and demolition projects.

Subject Property Overview

It is unknown when the structure was built. The area inspected consists of vinyl floor tiles. The unit was occupied at the time of the survey.

Inspection

Field activities were conducted on August 18, 2016, by Mr. Jose Moriel, licensed by the Texas

Department of State Health Services (TDSHS) as an Asbestos Building Inspector (license number 60-3220) with AnE Consulting Inc.

The survey was performed in general accordance with the National Emission Standards for Hazardous Air Pollutants (NESHAP) issued by the U.S. Environmental Protection Agency ( 40

CFR 61, Subpart M - National Emission Standard for Asbestos), the Asbestos Hazard Emergency Response Act (AHERA, 40 CFR 763), and the Asbestos School Hazard Abatement Reauthorization Act of 1990 (ASHARA, 40 CFR 763, Appendix C to Subpart E). These regulations generally require that, prior to any construction, renovation, or demolition, the area(s) where the work is to be performed shall be inspected by a properly trained and licensed or certified individual for the presence of ACMs that potentially may be disturbed during the work.

AnE employed a sampling strategy which involved identifying homogeneous materials throughout the proposed areas of work, and collecting bulk samples of the suspect materials for laboratory analysis for asbestos content. The term "homogeneous," as defined by in AHERA, means any material having the same color and texture, and having been installed in the same general time period.

The unit contained one (1) homogeneous area that was identified during the course of this survey, from which three (3) bulk samples were collected. Accessible areas of the unit were visually inspected. Destructive sampling was not conducted for this survey. These identified homogenous materials are summarized in Table 1 that follows.

Page 1 • Building 2011, Fort Bliss, TX - Limited Asbestos Survey • July 18, 2106 • (()2013 AnE Consulting, Inc.

Table 1-Summary of Homogenous Materials

Suspect ACM Location(s)

12" X 12" White Vinyl Floor Tile with Black Mastic Throughout

(Triple Layer)

The homogeneous materials were then assessed in terms of friability, condition, and quantity.

The term "friable" means a material that when dry can be reduced to a powder using hand pressure (25 TAC§ 295.32 (45)). Prior to sampling, each suspect asbestos material was properly wetted, and then each bulk sample was carefully extracted and placed in its own self-sealing container. Each container was wiped, sealed, and labeled with a unique sample number.

Appropriate chain of custody paperwork was completed listing each sample collected.

Laboratm.y Analysis

All samples were shipped under standard chain of custody protocols to Micro Analytical Services, Inc. (MAS) in Houston Texas. This facility is accredited by the National Voluntary

Laboratory Accreditation Program (NVLAP) for asbestos analysis, and licensed by the TDSHS as an asbestos laboratory (license number 30-0341).

The bulk samples were analyzed by Polarized Light Microscopy (PLM) coupled with Dispersion Staining in accordance with EPA Method 600/M4-82-020. The laboratory report with chain of custody documentation is attached to this report.

An ACM is defined as any material or product that contains greater trum one percent (1%) asbestos (25 TAC § 295.32 (15). Based on the laboratory data, the identified homogenous material was found to contain asbestos greater than one percent.

Table 2 - Summary of Asbestos-Containing Materials

Material Description Asbestos Content Condition / Friability

12" X 12" White Vinyl Floor Tile with Black Mastic 6% Chrysotile Non-Friable

(Triple Layer)

Page 2 • Building 2011, Fort Bliss, TX- Limited Asbestos Survey • July 18, 2106 • ©2013 AnE Consulting, Inc.

Summary of Findings

The following is a summary of findings based on the field activities conducted and laboratory analyses performed.

• Asbestos-containing 12" white vinyl floor tile black mastic was identified throughout.

The material was observed to be in good condition and considered non-friable. The estimated quantity of the material to be replaced is 450 square feet.

• All quantities are estimates and contractor shall field verify.

Recommendations

Based on the findings, AnE recommends the following:

• H the planned renovation or demolition activities will disturb the identified ACM, then the materials must be abated by a licensed/accredited abatement contractor in accordance with applicable Federal, State, and Local Rules and Regulations.

• A mandatory 10-day notification must be submitted in accordance with NESHAP for the planned abatement of the asbestos-containing materials. Written notification must be postmarked at least 10 working days prior to the start of the abatement. Responsibility for proper notification is that of the building owner, which may be delegated to the asbestos abatement contractor or consultant by the owner.

• H during the renovation or demolition project other suspect asbestos-containing materials are encountered, then the work must be stopped and the suspect asbestos containing material(s) should be tested for asbestos content.

Qualifications and limitations The discussions, findings, and recommendations contained herein are based upon data collected on the day of our investigation, the laboratory analysis of the samples collected, and typical practices accepted by the asbestos consulting profession. The scope of our work was limited to the subject areas and services stated in this report. Those building materials not inspected shall be assumed to contain asbestos unless laboratory analysis indicates otherwise.

Page 3 • Building 2011, Fort Bliss, TX - Limited Asbestos Survey • July 18, 2106 • ©2013 AnE Consulting, Inc.

:A-f.icro jlna[ytica{ Services, Inc. 11301 Richmond Ave. Ste.KIOOB♦Houston♦Tx 77082♦Phone(281)497-4SOO♦FIU(281)497-4517

NVLAP Lab No. 200618-0 TDSHS License No. 30-0341

CLIENT:

PROJECT:

PLM BULK ASBESTOS ANALYSIS REPORT

AnE Consulting, Inc.

Bldg. 2011

MAS JOB NO.: 12735-00

REPORT DATE: August 19, 2016

IDENTIFICATION: Asbestos, Bulk Sample Analysis, Quantitation by Visual Area Estimation

TEST METHOD: Polarized Light Microscopy with Dispersion Staining EPA Test Method 600/M4-82-020; (40CFR Part 763 Appendix E to Subpart E) &

EPA 600/R-93/116

STATEMENT OF LABORATORY ACCREDITATION

These samples were analyzed at Micro Analytical Services, Inc. in the Asbestos Laboratory at 11301 Richmond Ave. Suite Kl00B, Houston, Texas, 77082. The Laboratory holds accreditation from the National Institute of Standards and Technology under the National Voluntary Laboratory Accreditation Program (NVLAP). This laboratory is also licensed and authorized to perform as an Asbestos Laboratory in the State of Texas within the purview of Texas Civil Statutes, Article 4477-3a, as amended, so long as this license is not suspended or revoked and is renewed according to the rules adopted by the Texas Board of Health.

The samples were analyzed in general accordance with the procedures outlined in the Method for the Determination of Asbestos in Bulk Building Materials, EPN600/M4-82-020(40CFR Part 763 Appendix E to Subpart E) & EPA 600/R- 93/116 or the U.S. Environmental Protection Agency method, under AHERA, for the analysis of asbestos in building materials by polarized light microscopy. The results of each bulk sample relate only to the material tested and the results shall not be used to claim product endorsement by NVLAP or any agency of the U.S. Government.

Specific questions concerning bulk sample results shall be directed to the Asbestos Bulk Laboratory at Micro Analytical Services, Inc.

Analyst: Tony T. Dang

94..icro jl.na{ytica[ Services, Inc. 11301 Richmond Ave. Ste. KlOOB♦Holl8ton♦Texas 77082♦Phone(281)497-4500♦Fax(281) 497-4517

AnE Consulting, Inc.

912 Texas Ave. Suite B El Paso, Texas 79901

Field ID/ Layer# Lab ID

2011-01 1

MAS378133

2011-01 2

MAS378133

2011-01 3

MAS378133

2011-01 4

MAS378133

2011-01 5

MAS378133

2011-01 6

MAS378133

2011-01 7

MAS378133

2011-01 8

MAS378133

2011-02 1

MAS378134

2011-02 2

MAS378134

2011-02 3

MAS378134

2011-02 4

MAS378134

2011-02 5

MAS378134

2011-02 6

MAS378134

Polarized Light Microscopy Analysis

Project Name: Bldg. 2011 Sample Description Asbestos

Detected?

(Yes/No)

White non-fibrous floor tile No

Yellow non-fibrous mastic No

White non-fibrous floor tile No

Yellow non-fibrous mastic No

Beige non-fibrous floor tile No

Yellow non-fibrous mastic No

Beige fibrous floor tile Yes

Black fibrous mastic Yes

White non-fibrous floor tile No

Yellow non-fibrous mastic No

Purple non-fibrous floor tile No

Yellow non-fibrous mastic No

Beige non-fibrous floor tile No

Yellow non-fibrous mastic No

MAS Project#: 12735-00 Date Received: 08/19/2016 Date Analyzed: 08/19/2016

Asbestos Non-Asbestos Constituents Constituents

100% Other

100% Mastic

100% Other

100% Mastic

100% Other

100%Mastic

2% Chrysotile 98% Other

6% Chrysotile 94%Mastic l00%Other

100% Mastic

100% Other

100% Mastic

100%0ther

100% Mastic

Samples have been analyz.ed by the EPA Interim Method 600/M4-82-020(40CFR Part 763 Appendix E to Subpart E) & EPA 600/R-93/I 16. The test results herein relate only to the sample submitred and analyzed. This report may only be reproduced in full with the approval of the Bulk Asbestos Laboratory of Micro Analytical Services (MAS). The above percentages are visual estimates of area percent. MAS is not responsible for any errors resulting from improper or incorrect sampling or shipping procedures. These samples will be retained for a period of 30 days. Accreditation by NVLAP in no way constitutes or implies product certification, approval, or endorsement by NlST. Some materials, especially floor tiles, contain asbestos fibers too thin to be detected by this method.

NVLAP Lab Code: 2000618 IDSHS License: 30--0341

Analyzed by: Tony Dang Approved NVLAP Signatory: Tony Dang Page 1 of2

:Micro jlna{ytica{ Services, Inc. 11301 Richmond Ave. Ste. KIO0B♦Houston♦Texas 77082♦Phone(281) 497-4500♦Fax(281) 497-4517

Polarized Light Microscopy Analysis

AnE Consulting, Inc. MAS Project #: 12735-00 912 Texas Ave. Suite B Date Received: 08/19/2016 El Paso, Texas 79901 Date Analyzed: 08/19/2016

Project Name: Bldg. 2011 Field ID/ Layer# Sample Description Asbestos Asbestos Non-Asbestos Lab ID Detected? Constituents Constituents

(Yes/No) (%) (%) 2011-02 7 Beige fibrous floor tile Yes 2% Chrysotile 98%Other

MAS378134

2011-02 8 Black fibrous mastic Yes 6% Chrysotile 94%Mastic

MAS378134

2011-03 1 White non-fibrous floor tile No 100%Other

MAS378135

2011-03 2 Yellow non-fibrous mastic No 100%Mastic

MAS378135

2011-03 3 White non-fibrous floor tile No 100% Other

MAS378135

2011-03 4 Yellow non-fibrous mastic No 100% Mastic

MAS378135

2011-03 5 Beige non-fibrous floor tile No 100% Other

MAS378135

2011-03 6 Yellow non-fibrous mastic No 100% Mastic

MAS378135

2011-03 7 Beige fibrous floor tile No 3% Cellulose MAS378135 97% Other 2011-03 8 Black fibrous mastic Yes 6% Chrysotile 94% Mastic

MAS378135

Samples have been analyzed by the EPA lnterim Method 600/M4-82-020(40CFR Part 763 Appendix E to Subpart E) & EPA 600/R-93/116. The test results herein relate only to the sample submitted and analyzed. This report may only be reproduced in full with the approval of the Bulk Asbestos Laboratory of Micro Analytical Services {MAS). The above percentages ate visual estimates of area percent. MAS is not responsible for any errors resulting from improper or incorrect sampling or shipping procedures. These samples will be retained for a period of 30 days. Accreditation by NVLAP in no way constitutes or implies product certification, approval. oc endorsement by NIST. Some materials, especially floor tiles, contain asbestos fibers too thin to be detected by this method.

NVLAP Lab Code: 2000618 TDSHS License; 30-0341

Analyzed by: Tony Dang Approved NVLAP Signatory: Tony Dang Page 2 of2

9.1.icro Jlna{ytica[ Services, Inc. 11301 RichmondAve.SuitcKIOOB•Hous1on♦Texas 77082♦Phonc (:i:8l)497-4S00♦Flllt(281) 497-4517

Asbestos Bulle Sample Chain of Custody

Company: AnE Consultin2. Inc. Contact: Project Name:

Address: 912 Texas Ave. Ste.C Bill to: Nick Rodriwiez

Project#:

City: El Paso Email: a....ecr,nst>l4i~c:11¾-.nd State/Zip: Texas 79902 V, PO#:

Phone: (915)532-3788 I Fax: (915)532-3789 Date Collected: MAS Project#: J:::. ?~~" .

Tum around time (circle): Emergency 8 2-day 3-day 4-day 5-day

Field ID Lab ID Sample Description Sample Location Comments r71Jll-o I -~-iRJ_~< 12.1' 'F lcxv +·, le, tf.XJv ~\d..o. ?O\\ Y1 hl,·a.., Tx (J? '<hi:-1 -~ if \J\V),11 flee(+, \p_ fi.~ -~7R.t~~ Ill.+~ ~r.lL Mn,;+· t ...

j

Relinquished br-:::::!f·~: ...... - · ~--~,,..,...\ : :-t,t :;-·, ·_- _ ,. __ Date:._O~ ~~J -.·- -7~/~ _ __ Time:. __ /)-_'/Y"wL..--__ --

Received by=-~- -'d'>H. =--------~Date: ____ 4..,L~-- '/__1~_1b_~ __ Time:_ .... _4-__ • ..,.~'-"'"'-<;--J-~(--

Relinquished by:. __________ Date: ______ Time: ____ ___ _

Received by:. ___________ Date: ________ Time: _______ _

Page_of_ MAS.FlOJ

TEXAS DEPARTMENT OF STATE HEALTH SERVICES

ANE CONSULTING lNC is certifot! to perform a.s a

Asbestos ~onsultant Agency in the State of Texas within the purview of Texas Occupations Code, chapter 1954, so long as this license is not suspended or revoked and is 1·enewed according to the "'les adopted by the Texas Boa.rd of Health.

P~ /~//

DAVID LAKEY, M.D.

COMMISSIONER OF HEALTH

License Number: 10_0441 Expiration Date: 2/1/2011

Control Number: 96762 (Void After Expiration Date)

VOID IF ALTERED NON-TRANSFERABLE

~'t:. -~~~ ~b,__,._,,_.fJ.t,~ ,,,~I~,,;, - ;f..~*.l~ :.:., ,,t!' 11 ... ., • '•<\ -~·-•• :} f'-t' J . , ... , . \ \\.'" .

:I:~ . • ~/;-'-;P f,t,·•.',:Y1;' '\' ·:· . . ,.,- .\ .. ,i•-- • ...... .. --,~· ·- · ~ ~ ·:'"· • ·· .. ' , ,, ,,. J

\ ~~ •,i , • I ....,,, ~ ': 1~~-;J.f. .t

:i-. . .,,.;' --·

TEXAS n·EP J\RTMENT OF STATE HEAL TH. SERVICES

MICRO AN"ALYTICAL SERVICES INC

is certjfiei to perform as a

Asbestos· Laboratory

PCM,PLM .

in the State of Texas within the pttrview of Texas Occupations Code. chapter 1954. so long as· this license is not suspended or revoked and is renewed according to theintles adopted by the Te..'(as Board of Health.

. KlRK. COLE, INTERIM

COMMISSIONER OF HEALTH

License Number: 300341 Expiration·Date: 1/25/2018

Control Number: 96091 (Void After Expiration Date)

VOID IF ALTERED NQN .. TRANSFERABLE

Texas Department of ~tate Health Services·. •

. . . Asbestos lnspe~tor ,, .. .·, . . .

JOSEMORIEL

License No. 603~20

Control No, 97910

Expiration Date: 3/5/2017

File details come from the government source that posted it. Updated .