Bill of Materials for RFQ-2024687.xlsx

XLSX spreadsheet 107 KB Posted

Attached to
Brand Name or equal Cell Metric CLD - High throughput Clone reporting device
Solicitation number
RFQ-2024687
Issued by

View the file

Other files

File Type Posted
4_52.212-5 March2020.docx DOCX document
2 - RFQ-2024687 - Brand Name or Equal.doc DOC document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Brand name or equal - RFQ# RML-2024687
The proposed purchase is for Brand Name or Equal products. The brand name, and model
number, and part number of the product(s) are:
#DescriptionCatalogQty
1Cell Metric CLD--Includes: instrument, integrated temperature-controlled plate loader for 10 plates, PC Workstation, Barcode Reader, Verify Clonality Software, Monitor Cell Growth/Confluence Application, Clonality Reporting Software, 2 cassettesCC-1601 each
26 PACK Additional CLD Cassettes - Crate and packagingCC-10661 each
3Installation and trainingCC-10111 each
4Shipping and handling1 each
Warranty information MUST be included in the quote
Place of manufacturer must be included in the quote
Brand name - manufacturer www.solentim.com
To be considered for award, vendors of “equal” products, including “equal” products of the brand-name manufacturer, must meet the following criteria for the salient characteristics of the Cell Metric CLD - High throughput Clone reporting device equipment:
Required Salient Characteristics
1Clonality Report: a documentation package for providing assurance of clonality to the regulator as part of an IND. It includes all requirements cited by the FDA – whole well image, zoom in of single cell feature, explanation of any non-cell features, daily imaging history of single cell division and growth to a colony
2Batch summaries drastically reduce the amount of data storage required and just keep the clones of interest
3Imaging time of 3-4 minutes per plate in bright field with 100% focus guarantee across the whole plate. There is even illumination across the whole well so there are no dark edges where cells could be missed
4Validate cloning method e.g. FACS seeding, Uses 2-colour fluorescence, and Plate map of wells with the fluorescent object count (for generating statistics
5Vector design using transposases for targeting high-producer clones
6High efficiency single cell isolation in plates
7Whole well imaging of single cell to colony
8Growth supplements to ensure a high proportion of single cells survive and grow
9Clonality documentation and reporting package
10Bright field whole well imaging
11Imaging of settled suspension (typically CHO cells) or adherent cells
12Plate formats: typically, 96 and 384 well plates (but also 6, 12, 24, 48)
13built-in, incubated (at 37oC) plate loader for unattended imaging of 10 plates in a cassette
14Imaging time: 4-5 minutes for verify clonality; 3-4 minutes for confluence
15Built-in barcode reader
16Output CSV files to facilitate robotic cherry-picking of best clones
17Connectivity with the VIPS so that the droplet images from VIPS and the whole well images from Cell Metric CLD all end up in the same batch file and Clonality Report
18Option for remote data viewer license's – means that users can view data and analyze reports remotely at their desks rather than on the instrument computer
19Option for 2 color fluorescence (Red/Green) developed for cloning method validation experiments
20Option is available for IQ/OQ packages
21Automatic Imaging: Plates are imaged over a time course, typically, day 0, day 1, day 2, day 4/5, day 7, day 10/14
22Additional time points are possible as turnaround time is 4 to 5 minutes per plate (96 or 384 well)
23Day 10/14 to define the best growing colonies
24Day 4/5 to determine if a single colony is present
25Day 0 to identify single cell and debris in the well
26The possibility to track backwards from last time point and review wells of interest
2796 and 384 well plates for clone screening
2824 and 6 well plates for clone expansion and growth
29Computer System to operate Instrument: (Brand name or equal)
HP Elite Desk • Intel® 17® processor • 1 x512GB nvme + 2 x 2TB hard disk • Microsoft Windows 10, 64-bit • 24" flat screen monitor
30System Dimensions (H x W x D) (instrument can not exceed these dimensions) due to space limitations.
650 x 465 x 500 mm 25.6 x 18.3 x 19.7” Computer: 370 x 160 x 400 mm 14.7 x 6.2 x 15.8”
31Power requirements
100/240 V; 50/60 Hz; 3A (Instrument) 100/240 V; 50/60 Hz; 5A (Automated Plate Loader) 4 Plug sockets as follows: • PC & Monitor • Instrument & Plate loader
32Network - The computer will be connected to our internal network.
The PC will can be connected to the customer’s in-house network to enable remote support and/or data backup. Facilitates use of Remote Data Viewer.
33Image size
Whole plate image is approximately 150MB. Typical project of 14 days would generate around 3GB of data will be moved onto an external hard drive or archive on the network
34Remote Data Viewer
The option to view images and prepare reports from the office or from a remote location. Software that can be loaded onto multiple computer and may be sold/used on a per seat basis.
35Installation and Training
Alignment
• Imaging
• Focusing
• Bar code reader
Set up customer plate types
• Tune for customer Cell types
• Software training
To Includes ongoing support for next 12 months support

image1.png

File details come from the government source that posted it. Updated .