Bid Set 7-13-22-2019048 5r.pdf

PDF 5 MB Posted

Attached to
751/19159. SMD; Tawas Pt Lightstation - Masonry/Lantern Reno
Solicitation number
RFQ - 171 - 220000000452
Issued by
Iosco County, East Jordan City, Michigan

About this file

This document appears to be a bid set or construction drawing for the Masonry and Lantern Restoration project at the Tawas Point Light Station Tower in Tawas, Michigan. The project is being managed by the Michigan Department of Technology, Management and Budget, Facilities and Business Services Administration, Design and Construction Division under Contract No. 751/19159.SMD. The work includes relocating exposed conduit and wiring, installing new receptacles and lighting, and meeting NEC 2017 code requirements. The bid submission deadline is noted as July 13, 2022.

The bid documents provide detailed electrical floor plans and general notes, specifying the use of rigid metal conduit, THHN copper conductors, circuit identification, and prohibiting the use of Romex cable. The scope of work indicates the project is located in Iosco County and East Jordan City, Michigan. No additional pricing terms, set asides, funding sources, or other salient information is included in the provided materials.

View the file

Other files

File Type Posted
Bid Set 7-13-22-2019048 4r.pdf PDF
Addendum No. 1.pdf PDF
Advertisement 19159.pdf PDF
Bid Set 7-13-22-2019048 1r.pdf PDF
Specifications 19159.pdf PDF
Bid Set 7-13-22-2019048 3r.pdf PDF
Bid Set 7-13-22-2019048 2r.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIRST FLOOR PLAN - ELECTRICAL

1/8"=1'-0"

EX 200 MCB

PANEL

EC SHALL RELOCATE THE

EXPOSED SURFACE CONDUIT TO

BE CONCEALED WITHIN THE NEW

COILED WALL

S

EX

JB

EX

GFI

EXISTING BASEMENT PANEL PICTURE 2

EXISTING BASEMENT PANEL PICTURE 1

EXISTING CONDUIT THAT

ENTERS TOWER CORRIDOR

THAT SHALL BE RELOCATED TO

BE CONCEALED IN WALL.

SHOWN HERE AS REFERENCE

UPPER TOWER LANTERN AREA

REPLACE RECEPTACLE WITH A

NEW GFI RECEPTACLE AND

COVERPLATE

RELOCATE EXPOSED CONDUIT

TO BE CONCEALED WITHIN THE

NEW COILED DOOR WALL

CONNECTOR CORRIDOR

BASE TOWER

GFI

EC SHALL INTERCEPT THE

EXISTING TOWER LIGHTING

CIRCUIT TO POWER A NEW

TOWER RECEPTACLE. ROUTE

NEW CONDUIT AND WIRING

THROUGH THE TOWER CHASE

WALL CAVITY FROM THE

EXISTING JUNCTION BOX TO A

NEW SURFACE MOUNTED

RECEPTACLE MOUNTED

BEHIND THE STAIRS.

GENERAL NOTES

1. EC SHALL UTILIZE RIGID METAL CONDUIT FOR

ALL CONDUIT INSTALLED EXPOSED.

2. EC SHALL UTILIZE THHN COPPER

CONDUCTORS FOR NEW WIRING

3. EC SHALL PROVIDE CIRCUIT IDENTIFICATION

ON ALL NEW DEVICES.

4. ROMEX IS NOT ACCEPTABLE FOR USE

ANYWHERE ON THIS PROJECT.

5. EC SHALL OBTAIN ALL PERMITS FOR THE

ELECTRICAL WORK AND MEET NEC 2017

REQUIREMENTS.

6. ALL RECEPTACLES SHALL BE DARK BROWN

BODY, 20AMP, TAMPER RESISTANT, GFI

RECEPTACLES.

SHEET NUMBERPROJECT NUMBER

PROJECT DATE

CHECKED BY

SHEET TITLE

COPYRIGHT 2022

C

Saginaw, Michigan 48607

100 S Jefferson Ave, Suite 601

WTAARCH.COM

ARCHITE SCT

DATENO. REVISION

PROJECT TITLE

INDEX NO.

751/19159.SMD

FILE NO.

P

L

U

R

I B U

E

S

U

N

U

M

C

I

R

C

U M S

P

I

C

E

S

I

Q

U

ER

EI S

P ENI NSUL AM

A M

O

E

N

A

M

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

STATE OF MICHIGAN

ROBERT C. HALL, RA, NCARB, DIRECTOR

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

DESIGN AND CONSTRUCTION DIVISION

00625

CONTRACT NO.

(989) 894-4300 F (989) 894-9930 www.macmillanassociates.com

714 EAST MIDLAND STREET BAY CITY, MICHIGAN 48706

MacMILLAN ASSOCIATES

CONSULTING ENGINEERS

MASONRY AND LANTERN RESTORATION FOR:

TAWAS POINT

LIGHT STATION TOWER

TAWAS, MICHIGAN

2019048

JULY 13, 2022

04.19.22FINAL OWNER REVIEW

07.13.22SUBMIT FOR BIDDING

ELECTRICAL PLAN

JWF

E1

Sheets and Views
2021-1510-E-E1 ELECTRICAL FLOOR PLAN-Model
LIMITS

File details come from the government source that posted it. Updated .