BID PERMIT-062526 - SANDUSKY SCHOOLS STORAGE BLDG (sealed).pdf
PDF 2 MB Posted
- Attached to
- RFP Storage Project
- Solicitation number
- RFP SAN 260000002322 1
- Issued by
- Sanilac County, Michigan
About this file
This is a Bid Permit document for the City of Sandusky, Michigan, issued for a new accessory storage building project for Sandusky Community Schools located at 125 Davis Street in Sandusky, Michigan. The project involves construction of a non-sprinklered, unheated storage structure classified as Building Code Authority Type VB with Occupancy Classification U (Utility). The structure will feature separate storage units with individual department access, exterior electrical outlets, new lighting fixtures, and minimal site work. The design is governed by the 2021 Michigan Building Code, 2021 Michigan Mechanical Code, 2021 Michigan Plumbing Code, 2023 National Electric Code, and applicable accessibility standards including ADA and ICC ANSI 117.1-2017. The project documents include architectural foundation plans, floor plans, exterior elevations, building sections, door schedules, and material legends. The registered design professional in responsible charge is Shane M. Burley, AIA, NCARB of Studio Detroit, LLC in Detroit, Michigan, and the owner contact is Kurt Dennis of Sandusky Community Schools. The bid permit was issued for June 25, 2026, with contractors required to complete a site visit before submitting bids and provide a detailed critical path construction schedule within five days of contract execution.
The general contractor is responsible for submitting deferred submittals including structural calculations, concrete foundation reviews, engineered truss drawings, lateral bracing details, electrical power and lighting compliance documentation, interior finish flame spread testing data, and roofing system specifications to the authority having jurisdiction. The contractor must obtain all required construction permits and comply with applicable regulatory requirements, codes, ordinances, and ADA accessibility standards. Work is limited to the defined scope and limits of construction, with any changes or additional work requiring prior written approval from the architect. The contractor shall provide daily and final cleaning, prepare a punch list upon project completion, submit warranties and certifications, obtain occupancy permits, and deliver operation and maintenance manuals and project record documents to the owner. No pricing, funding sources, set-asides, or contract award information is specified in this permit document.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUILDING CODE AUTHORITY
CITY OF SANDUSKY, MI
CONSTRUCTION CLASSIFICATION
VB, NON-SPRINKLERED
OCCUPANCY CLASSIFICATION
U - UTILITY
PROJECT DATAPROJECT SUMMARY
PROJECT INCLUDES NEW ACCESSORY STORAGE STRUCTURE WITH SEPARATE UNITS
AND ACCESS FOR DIFFERENT DEPARTMENTS. STRUCTURE TO BE UNHEATED WITH NO
PLUMBING IN THE STRUCTURE. ELECTRICAL SCOPE WILL BE LIMITED TO EXTERIOR
OUTLETS AND NEW LIGHTING FIXTURES. MINOR SITE WORK WILL BE INDICATED, BUT
CIVIL ENGINEERING IS NOT INCLUDED.
BUILDING CODES
BUILDING CODE
ALSO KNOWN AS THE "MICHIGAN BUILDING CODE"
2021 MICHIGAN BUILDING CODE (MBC) AS AMENDED
MECHANICAL CODE
ALSO KNOWN AS THE "MICHIGAN MECHANICAL CODE"
2021 MICHIGAN MECHANICAL CODE (MMC) AS AMENDED
PLUMBING CODE
ALSO KNOWN AS THE "MICHIGAN PLUMBING CODE"
2021 MICHIGAN PLUMBING CODE (MPC) AS AMENDED
ELECTRICAL CODE
2023 NATIONAL ELECTRIC CODE (NEC)
AMERICANS WITH DISABILITIES ACT; ALSO KNOWN AS ADA
ICC . ANSI 117.1 - 2017
MBC-2021 CHAPTER 11
2021 MICHIGAN COMMERCIAL ENERGY CODE; 2021 IECC
w/ AMENDMENTS AND ANSI/ASHRAE/IESNA STANDARD 90.1-2019 w/ AMENDMENTS
2021 INTERNATIONAL FUEL GAS CODE
2021 INTERNATIONAL FIRE CODE
NFPA 13 - 2019
NFPA 72 - 2019
OWNER
SANDUSKY COMMUNITY SCHOOLS
KURT DENNIS
191 E. PINETREE LANE
(810) 648-3400 kdennis@sandusky.k12.mi.us
DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE:
SHANE M. BURLEY, AIA, NCARB
STUDIO DETROIT, LLC
2040 PARK AVENUE, SUITE 200
DETROIT, MI 48226
E. SHANE@STUDIO-DETROIT.COM
P. 313.919.5886
MICHIGAN LICENSE NUMBER 1301058978
EXPIRES: 03.09.27
NOTE:
GENERAL CONTRACTOR SHALL COORDINATE WITH THEIR MATERIAL SUPPLIERS AND THE
REGISTERED DESIGN PROFESSIONAL IN CHARGE TO SUBMIT THE FOLLOWING DEFERRED SUBMITTALS
TO THE AUTHORITY HAVING JURISDICTION:
1. STRUCTURAL CALCULATIONS
2. REVIEW / SPECIAL INSPECTION OF EXISTING AND NEW CONCRETE FOUNDATION CONDITIONS
3. ENGINEERED TRUSS DRAWINGS
4. PERMANENT LATERAL TRUSS BRACING DETAILS (PER 2303.4.1, 2303.1)
5. REVIEW OF CONCRETE SPECIAL INSPECTIONS
6. ELECTRICAL POWER / LIGHTING COMPLIANCE
7. INTERIOR FINISHES -FLAME SPREAD TESTING DATA FROM MATERIAL MANUFACTURER
8. ROOFING SYSTEMS
NOTE:
THESE CONSTRUCTION DRAWINGS WERE PREPARED FOR COMPLIANCE WITH THE MICHIGAN
CONSTRUCTION CODES IN EFFECT AT THE TIME OF PERMIT SUBMITTAL. ALL ENGINEERS,
CONTRACTORS AND SUPPLIERS INVOLVED WITH THIS PROJECT SHALL COMPLY WITH THE SAME
CODES, ISSUED AND APPROVED CODE MODIFICATIONS AND/OR CITY CODE AUTHORITY
CONSTRUCTION BOARDS OF APPEALS RULINGS AND WHENEVER REQUIRED SHALL PROVIDE SHOP
DRAWINGS AND SUBMITTALS CLEARLY DESCRIBING COMPLIANCE TO THE REGISTERED DESIGN
PROFESSIONAL IN RESPONSIBLE CHARGE FOR REVIEW AND APPROVAL.
VICINITY MAP
SITE
S
S A
N D
U S
K Y
R D
E. MILLER RD
E. PINETREE LN
C A
M P
B E
L L
R D
D A
V
IS
S T
JEAN ST
LIST OF ALTERNATES
ALT #1:
NUMBER DESCRIPTION
ALT #2:
ALT #3:
PROVIDE CONCRETE APRON AT EXTERIOR OF ALL ROLL-UP DOORS
.4
.0
.9
± 87.3 ' ± 40.0 ' ± 28.0 ' 80.0 '
.9
.0
D A
V
IS
S T
R E
E T
THIS DOCUMENT AND THE INFORMATION
CONTAINED THEREIN IS THE SOLE
POSSESSION OF STUDIO DETROIT AND
SHALL NOT BE ALTERED OR MODIFIED
WITHOUT THE EXPRESS WRITTEN
PERMISSION OF STUDIO DETROIT. ANY
MODIFICATION OR ALTERATION THEREOF
SHALL INDEMNIFY AND HOLD HARMLESS
STUDIO DETROIT OF ALL EXPENSES, CLAIMS
AND/OR LIABILITY RESULTING FROM SUCH
MODIFICATIONS OR ALTERATIONS.
� 2026 STUDIO DETROIT LLC
DO NOT SCALE DRAWINGS
2040 PARK AVENUE, SUITE 200
DETROIT, MICHIGAN 48226
STUDIO-DETROIT.COM
ISSUED
DRAWN
CHECKED
SEAL
CLIENT
PROJECT
PROJECT MANAGER
PROJECT NO.
191 PINE TREE LANE
SANDUSKY, MI 48471
SANDUSKY
COMMUNITY SCHOOLS
STORAGE BUILDING
TS1.1
SMB
PNP
COVERSHEET
SANDUSKY COMMUNITY
SCHOOLS
STORAGE BUILDING
06.25.26 BID / PERMIT
125 DAVIS STREET
SANDUSKY, MI 48471
125 DAVIS STREET
SANDUSKY, MI 48471
SANDUSKY
COMMUNITY SCHOOLS
PETER PENTESCU
PETE@STUDIO-DETROIT.COM
586.747.9717
26031
.2
.2
B
ID
P
E R
M
IT
ISSUED FORSHEET INDEX
DRAWING INDEX KEY
NOT ISSUED
PREVIOUSLY ISSUED
ISSUED
REFERENCE
GENERAL
TS1.1 COVERSHEET
TS1.2 SYMBOLS + ABBREVIATIONS
TS1.3 CODE STUDY
ARCHITECTURAL
A1.0 ARCHITECTURAL FOUNDATION PLAN
A1.1 FLOOR PLAN
A2.1 EXTERIOR ELEVATIONS
A3.1 BUILDING SECTIONS
A4.1 DOOR SCHEDULE + ROOM FINISH SCHEDULE
N
1" = 30'-0"
PARTIAL ARCHITECTURAL SITE PLAN
A5.1
MATERIAL LEGEND
F
SYMBOL LEGEND ABBREVIATION
A5.1
DETAIL NAME
ROOM NAME
COORDINATE WITH SCHEDULE
DOOR DESIGNATION
KEY NOTE DESIGNATION NUMBER -
COORDINATE WITH PLAN NOTES
COORDINATE WITH PLAN NOTES
EQUIPMENT DESIGNATION NUMBER -
ADDENDUM DESIGNATION NUMBER
BULLETIN DESIGNATION NUMBER
BLOCKING/ROUGH LUMBER
BATT/LOOSE INSULATION
ACOUSTICAL CEILING
FINISHED WOOD
GYPSUM WALLBOARD
WALL TYPE DESIGNATION NUMBER -
SHEET REFERENCE FOR DRAWING CONTINUATION
PLYWOOD
MASONRY
CONCRETE
MATCH LINE
SEE SHEET: A3
ELEVATION NUMBERS
DETAIL REFERENCE NUMBER
ELEVATION NUMBER
HEIGHT ABOVE FINISHED FLOOR
REFERENCE POINT OF ELEVATION
HEIGHT ABOVE FINISHED FLOOR
EXISTING DOOR SYMBOL
CIRCLES REPRESENT NEW COLUMN LINES
LETTERS DESIGNATE HORIZONTAL COLUMN LINES
SQUARES REPRESENT EXISTING COLUMN LINES
NUMBERS DESIGNATE VERTICAL COLUMN LINES
SHEET NUMBER WHERE DETAIL IS REFERENCED
NOTE: DATUM SYMBOL INDICATES A SPECIFIC
REFERENCE HEIGHT OF MATERIAL INDICATED
SHEET NUMBER WHERE DETAIL IS LOCATED
SHEET NUMBER WHERE ELEVATION IS LOCATED
ARROWS INDICATES ELEVATED SECTION
SHEET NUMBER WHERE ELEVATION IS LOCATED
NEW DOOR SYMBOL
B
A
B./CEILING
EL. 8'-0" A.F.F.
8'-0"
ROOM NUMBER
ROOM NAME
DRAWING SCALE
DETAIL NAME
DETAIL NUMBER
A
A3.4
A1.1 SCALE: 1/2" = 1'-0"
### DOOR TYPE
FRAME MATERIAL
DOOR MATERIAL
@ AT
ACOUST. ACOUSTICAL
A.C.T. ACOUSTIC CEILING TILE
ADJ. ADJACENT
A.F.F. ABOVE FINISH FLOOR
ALUM. ALUMINUM
ANOD. ANODIZED
BD. BOARD
BLDG. BUILDING
BLK. BLOCK
BLKG. BLOCKING
B.O. BOTTOM OF
B.O.S. BOTTOM OF STEEL
CEM. CEMENT
C.G. CORNER GUARD
C.J. CONTROL JOINT
CLG. CEILING
C CENTER LINE
C.O. CLEAN OUT
COL. COLUMN
CONC. CONCRETE
CONST. CONSTRUCTION
CONT. CONTINUOUS
CORR. CORRUGATED
CPT. CARPET
C.T. CERAMIC TILE
DET. DETAIL
DIA. DIAMETER
DM. DIMENSION
DN. DOWN
D.O. DOOR OPENING
DR. DOOR
DWG. DRAWING
EA. EACH
ELEV. ELEVATION
E.W. EACH WAY
EXG. EXISTING
EXIST. EXISTING
EXP. EXPANSION, EXPOSED
EXT. EXTERIOR
F.D. FLOOR DRAIN
FDN. FOUNDATION
F.R.P. FIBER REINFORCED PANELS
FIN. FINISH
FLR. FLOOR
F.O. FACE OF
F.O.S. FACE OF STUD
FR. FRAME
FTG. FOOTING
GA. GAUGE
GALV. GALVANIZED
GYP. GYPSUM
HDW. HARDWARE
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
HT. HEIGHT
I.D. INSIDE DIAMETER
INSUL. INSULATION
INT. INTERIOR
JT. JOINT
LAV. LAVATORY
LG. LONG
L.L.O. LONG LEG OUTSTANDING
L.L.V. LONG LEG VERTICAL
MAS. MASONRY
MAX. MAXIMUM
MECH. MECHANICAL
MET. METAL
MEZZ. MEZZANINE
MFR. MANUFACTURER
M.I. MISCELLANEOUS IRON
MIN. MINUMIM
MISC. MISCELLANEOUS
M.O. MASONRY OPENING
N.I.C. NOT IN CONTRACT
N.T.S. NOT TO SCALE
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
OHD OVERHEAD DOOR
OPNG. OPENING
OPP. OPPOSITE
PL.G. PLATE GLASS
PL.S. PLATE STEEL
P.LAM PLASTIC LAMINATE
PLAS. PLASTER
PREFAB. PREFABRICATED
PROJ. PROJECT, PROJECTION
P.S.F. POUNDS PER SQUARE FOOT
PT. PAINT, POINT
R. RISER
R.A. RETURN AIR
R.B. RUBBER BASE
R.C. ROOF CONDUCTOR
R.C.P. REFLECTED CEILING PLAN
R.D. ROOF DRAIN
R.F. RUBBER FLOORIING
REINF. REINFORCED, REINFORCING
REQ'D REQUIRED
RFG. ROOFING
RM. ROOM
R.S. ROOF SUMP
R.T. RUBBER TILE
SAN. SANITARY
SCHED. SCHEDULE
SHT. SHEET
SIM. SIMILAR
SPEC. SPECIFICATION
S.S. SERVICE SINK
STL. STEEL
STD. STANDARD
STOR. STORAGE
STRUCT. STRUCTURAL
SUSP. SUSPENDED
SW. SWITCH
SYM. SYMMETRICAL
T. TREAD
T&B TOP AND BOTTOM
TEL. TELEPHONE
TERR. TERRAZZO
T&G TONGUE AND GROOVE
THK. THICK, THICKNESS
THRES. THRESHOLD
T.O. TOP OF
T.O.S. TOP OF STEEL
TYP. TYPICAL
U/C UNDERCUT, UNDERCOUNTER
U.N.O. UNLESS NOTED OTHERWISE
V.B. VINYL BASE
V.C.T. VINYL COMPOSITION TILE
V.P.F. VINYL PLANK FLOORING
V.I.F. VERIFY IN FIELD
W. WIDE
VERT. VERTICAL
WAINS. WAINSCOT
W.C. WATER CLOSET
WD. WIN. WOOD WINDOW
WT. WEIGHT
W.W.F. WELDED WIRE FABRIC
w/ WITH
L
H M
H M
TOILET STALL
ACCESS PANEL
PAPER TOWEL
DISPENSER AND
WASTE
RECEPTACLE
16"x16" HINGED
PANEL, UNLESS
NOTED
OTHERWISE
SURFACE
MOUNTED
MIRROR
WALL MOUNTED
SOAP DISPENSER
SANITARY NAPKIN
RECEPTACLE
BARRIER FREE
GRAB BAR AT
REAR WALL
* REFLECTING
SURFACE
6" MAX.
MIN.
36"
M
IN
M
A X
20"
/2
M
A X
M
A X
M
A X
ELEV
SEE
W
IT
H M
E C
H
C O
O R
D
IN
A T
E
UNDER
LAVATORY
ACCESS PANEL
24"x24" HINGED
PANEL, UNLESS
NOTED
OTHERWISE
WATER CLOSET
PAPER TOWEL
DISPENSER
DASHED LINE
INDICATES
REQUIRED
CLEARANCES
FLUSH VALVE
SHALL FACE
TRANSFER SIDE OF
TOILET
WALL MOUNTED
LAVATORY
MIN.
17"
3" MAX.
M
IN
8" MIN.
11" MIN.2
M
IN
M
IN
M
A X
M
IN
M
A X
M
A X
MOUNTING SCHEDULE
RESTROOM ACCESSORIES AND PLUMBING FIXTURES
BARRIER FREE
GRAB BARS AT
SIDE WALL
MIN.
54"
41" MAX.
39" MIN.
M
A X
M
IN
M
IN
M
A X
M
IN
42" MIN.
MAX.
12"
TOILET TISSUE
DISPENSER OUTLET
(ABOVE GRAB BAR)
9" MAX.
7" MIN.
M
A X
TOILET TISSUE
DISPENSER OUTLET
(BELOW GRAB BAR)
4'-0"
15" MIN.
16" MIN.
18" MAX.
ELECTRIC WATER
COOLERS
M
A X
M
A X
M
IN
M
IN
-1
/2
M
IN
9" MAX.
7" MIN.
M
A X
URINAL
42" MIN.
TOILET SEAT
COVER DISPENSER
M
IN
/2
M
IN
FIN.FLR.LINE FIN.FLR.LINE
WALL
DESK
Text Graphic to be a min of 1" & must be approved by Architect.
EXITFIRE EXTINGUISHER
SHALL BE INSTALLED 48"
MAX TO HIGHEST
OPERABLE PART.
4" MIN
S T
D
M
A X
M
A X
FIN.FLR.LINE
M
A X
FIN.FLR.LINE
ROOM
NO.
USE
EXIT
STAIR
M
A X
FIN.FLR.LINE
M
A X
FIN.FLR.LINE FIN.FLR.LINE
M
IN
M
A X
VARIES
FIN.FLR.LINE
M
A X
FIN.FLR.LINE
C L
E A
R
'-8
M
IN
FIN.FLR.LINE FIN.FLR.LINE
Text Graphic to be a min of 1" & must be approved by Architect.
MOUNTING SCHEDULE
DUPLEX OUTLET KEY SWITCH or
PUSH BUTTON FORWARD
APPROACH
KEY SWITCH or
PUSH BUTTON PARALLEL
APPROACH
ROOM NAME
SIGN
FIRE EXIT SIGN
@ ELEVATORS
CARD READER LIGHT SWITCH
or DIMMER
FIRE EXTINGUISHER &
PANEL CABINETS
FIRE ALARM
PULL BOX
HVAC CONTROLS EXIT LIGHT CLOCK OUTLET TELEPHONE
WALL JACKS
TYPICAL WALL MOUNTED ACCESSORIES
LATCH
APPROACH
HINGE
APPROACH
X
Y
PULL SIDE
HINGE APPROACH
IF Y=60" MIN, THEN X=36" MIN
IF Y=54" MIN, THEN X=42" MIN
LATCH APPROACH
X=24" MIN
Y=48" MIN *
* Y=54" MIN IF CLOSER IS PROVIDED
LATCH
APPROACH
HINGE
APPROACH
APPROACH
24" @ LATCH
Y
PUSH SIDE
HINGE APPROACH
Y=42" MIN *
* Y=48" MIN IF BOTH CLOSER AND LATCH ARE PROVIDED
LATCH APPROACH
Y=42" MIN *
* Y=48" MIN IF CLOSER IS PROVIDED
APPROACH
22" @ HINGE
32" MINIMUM
CLEAR WIDTH AT
DOOR OPENINGS
32" MINIMUM
CLEAR WIDTH AT
DOOR OPENINGS
PULL SIDE
MIN.
18"
M
IN
(4
M
IN
. A
T E
X T
G
B L
D G
S
M
IN
(BOTH) LATCH AND CLOSER
12" MIN. *IF DOOR HAS
PUSH SIDE
32" MINIMUM
CLEAR WIDTH AT
DOOR OPENINGS
OVERLAP OF
KNEE AND TOE
CLEARANCE
CLEAR
FLOOR
SPACE
MIN.
1'-0"
MIN.
3'-4"
MIN.
1'-0"
5'-4" MIN.
M
IN
'-8
M
IN
'-4
'-0
M
IN
'-4
2'-6"
M A
X ø 5' - 7"
CLEAR
FLOOR
SPACE
TURNING SPACES SHALL BE PERMITTED TO INCLUDE KNEE
AND TOE CLEARANCE COMPLYING WITH SECTION 306 OF
EITHER THE BASE OR ONE ARM.
GENERAL ACCESSIBILITY NOTES:
THIS SITE / BUILDING SHALL COMPLY WITH THE PROVISIONS OF THE ACCESSIBILITY STANDARDS FOR THE JURISDICTION WHERE THE PROJECT IS LOCATED, INCLUDING, BUT NOT LIMITED TO ITEMS
NOTED: DOOR SIZES AND APPROACHES, THRESHOLDS, HARDWARE, TOILET ROOMS AND
ACCESSORIES, FIXTURES AND INSTALLATIONS, ETC. THE FOLLOWING SECTIONS ARE NOTED FOR
QUICK REFERENCE AND OTHER ITEMS ARE DETAILED WITHIN THE DRAWINGS. NOTE:
CONSTRUCTION TOLERANCES MAY OR MAY NOT ALLOW VARIATION TO THE DIMENSION SHOWN. A
SECTION NUMBER WITHOUT AN ACRONYM IS PART OF BOTH ACCESSIBILITY STANDARDS (ANSI OR
ADA) POSSIBLY NOTED ABOVE:
1. THIS SITE / BUILDING SHALL BE ACCESSIBILE AT ALL PRIMARY ENTRANCES AND SUCH
ACCESSIBLE ROUTE SHALL CONNECT ALL ACCESSIBLE SPACES AND ELEMENTS WITHIN THE
BUILDING FROM PARKING LOT TO PRIMARY ENTRY SHALL BE VIA ACCESSIBLE ROUTE - INCLUDE
ACCESS FROM ACCESSIBLE PARKING SPACES TO THE ACCESSIBLE ENTRY OF THE BUILDING
AND INTERIOR ACCESSILBE AREAS.
A. PRIVATE BUILDINGS / FACILITIES ARE NOT REQUIRED TO HAVE AN ACCESSIBLE ROUTE
CONNECT AN UPPER STORY IF FOOTPRINTS ARE LESS THAN 3,000 SF MAX OR BUILDINGS
THAT ARE LESS THAN 3 STORIES.
B. HISTORIC BUILDINGS (IF CERTAIN APPROVED AGENCIES) CERTIFY THAT UPDATES WOULD
DESTROY HISTORICAL SIGNIFICANCE OF THE BUILDING.
2. GROUND FLOOR WALKING SURFACES ALONG ACCESSIBLE ROUTES, IN ROOMS AND SPACES,
INCLUDING FLOORS, WALKS, RAMPS, STAIRS, AND CURB RAMPS, SHALL BE STABLE, FIRM, SLIP-
RESISTANT, AND SHALL COMPLY WITH ACCESSIBILITY CODES AND STANDARDS. ALL OBJECTS
WHICH OVERHANG OR PROTRUDE INTO BUILDING INCLUDING INTERIOR CIRCULATION PATHS
OF AN ACCESSIBILE ROUTE SHALL COMPLY WITH ACCESSIBILITY CODES AND STANDARDS AS
THEY RELATE TO PROTRUDING OBJECTS (NOT EXCEEDING 4" PROJECTION.)
3. CHANGES IN SURFACE MATERIALS, FOR ELEVATION CHANGES ACCOMPLISHED BY PROVIDING
REQUIRED RAMPS OR A CURB RAMP (WITHOUT HANDRAILS.) CHANGES IN LEVEL UP TO 1/4"
VERTICAL MAT BE WITHOUT EDGE TREATMENT. CHANGES IN LEVEL BETWEEN 1/4" AND 1/2"
SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2. CHANGES IN LEVEL GREATER THAN
1/2" SHALL BE ACCOMPLISHED BY MEANS OF A RAMP THAT COMPLIES WITH ACCESSIBILITY
CODES AND STANDARDS.
4. CARPET OR CARPET TILE USED ON A GROUND FLOOR OR A FLOOR SURFACE SHALL BE
SECURELY ATTACHED, HAVE A FIRM (A) CUSHION, PAD, OR BACKING, OR (B) HAVE NO CUSHION OR PAD; AND HAVE A LEVEL LOOP, TEXTURED, LEVEL CUT PILE, OR LEVEL CUT / UNCUT PILE TEXTURE. THE MAXIMUM PILE THICKNESS SHALL NOT EXCEED 1/2". EXPOSED EDGES SHALL BE
FASTENED TO THE FLOOR SURFACES AND HAVE A TRIM ALONG THE ENTIRE LENGTH OF THE
EDGE EXPOSED.
5. REACH RANGES SHALL NOT EXCEED 48" IN HEIGHT; MINIMUM 15" OR 2'-0" IN DEPTH, FOR
ELECTRICAL OUTLETS, SWITCHES, AND CONTROLS.
6. DOOR APPROACHES REQUIRE A MINIMUM OF 18" CLEAR ON PULL SIDE AND 0" ON PUSH SIDE
(12" ON PUSH SIDE IF DOOR HAS CLOSER.)
GENERAL PROJECT NOTES:
1. ALL WORK IS TO BE COMPLETED IN ACCORDANCE WITH THE DOCUMENTS, WHICH INCLUDES
THE DRAWINGS AND THE PROJECT SPECIFICATIONS CONTAINED IN THE PROJECT MANUAL.
2. ALL DOCUMENTS ARE COMPLEMENTARY AND NEITHER THE DRAWINGS NOR THE
SPECIFICATIONS TAKE PRECEDENCE OVER THE OTHER. CONTRACTOR SHALL NOTIFY
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DOCUMENTS BEFORE PROCEEDING.
FAILURE TO DO SO WILL RESULT IN THE CONTRACTOR TAKING FULL RESPONSIBILITY AND
LIABILITY FOR SAID DISCREPANCIES.
3. IT IS THE INTENT THAT CONSTRUCTION COMPLY WITH ALL APPLICABLE CODES AND LAWS
INCLUDING THE AMERICANS WITH DISABILITIES ACT (ADA). SHOULD ANY CONTRACTOR NOTICE
DRAWINGS OR WORK THAT HE / SHE BELIEVES IS NON-COMPLIANT, NOTIFY THE ARCHITECT /
ENGINEER IMMEDIATELY FOR REVIEW AND CORRECTIVE ACTION AS REQUIRED.
4. DO NOT SCALE THE DRAWINGS AS THEY ARE NOT NECESSARILY TO SCALE. THE CONTRACTOR
SHALL LAY OUT ALL GRIDS AND / OR MAJOR DIMENSIONS PRIOR TO THE START OF
CONSTRUCTION. IF DISCREPANCIES ARE FOUND, THE ARCHITECT / ENGINEER SHALL BE
NOTIFIED FOR CLARIFICATION BEFORE COMMENCEMENT OF THE WORK. EXPLICIT DIMENSIONS
HAVE PRECEDENCE OVER SCALE. CONTRACTOR SHALL INSTALL THE WORK IN ACCORDANCE
WITH DIMENSIONS INDICATED IN THE CONTRACT DOCUMENTS.
5. SUBCONTRACTORS FOR EACH TRADE ARE ADVISED THAT INFORMATION PERTINENT TO THEIR
WORK MAY OCCUR IN OTHER PORTIONS OF THE CONTRACT DOCUMENTS. REFER TO CIVIL,
STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SPECIAL SYSTEM DRAWINGS FOR
ADDITIONAL GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS.
6. THE ARCHITECTURAL DRAWINGS ARE OF EQUAL IMPORTANCE WITH THE CIVIL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SPECIAL SYSTEM DRAWINGS IN DEFINING THE
WORK OF THE CONTRACT DOCUMENTS. IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO COORDINATE WITH THE ARCHITECTURAL DRAWINGS BEFORE INSTALLATION
OF THESE OTHER SYSTEMS.
7. ALL NOTES ARE TO BE REVIEWED AND APPLIED TO RELATED BUILDING COMPONENTS. NOTES
APPEAR ON VARIOUS SHEETS FOR DIFFERENT SYSTEMS AND MATERIALS. ALL SHEETS ARE TO
BE REVIEWED AND NOTES ON ANY ONESHEET ARE TO BE APPLIED ON RELATED DRAWINGS AND
DETAILS.
8. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE SHOWN AND REFERENCED.
WHERE SPECIFIC DIMENSIONS, DETAILS, OR DESIGN INTENT CANNOT BE DETERMINED,
CONSULT THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. "TYPICAL" MEANS THE
CONDITIONS ARE THE SAME FOR ALL SIMILAR CONDITIONS UNLESS NOTED OTHERWISE.
9. DETAILS, SYSTEMS, AND / OR MATERIALS WHICH ARE PROPOSED TO BE CHANGED SHALL BE
SUBMITTED FOR APPROVAL AND REVIEWED BY THE ARCHITECT / ENGINEER PRIOR TO
COMPLETION AND SUBMISSION OF THE SHOP DRAWINGS. SUBMITTAL OF PROPOSED
SUBSTITIONS RESULTING IN AN AESTHETIC CHANGE SHALL NOT BE APPROVED.
10. REFER TO THE LIFE SAFETY DRAWINGS FOR SPECIFIC INFORMATION RELATED TO OCCUPANT
COUNTS, EXITING, AND WALL / ASSEMBLY RATINGS.
11. PROVIDE FIRE EXTINGUISHERS THROUGHOUT THE CONSTRUCTION AREA AS REQUIRED BY CODE
FOR THE DURATION OF WORK.
12. FINISH FLOOR ELEVATIONS ARE TO TOP OF CONCRETE UNLESS OTHERWISE NOTED.
A. FIRST FLOOR ELEVATION: (100'-0")
CONTRACTOR GENERAL CONDITIONS NOTES:
1. THE CONTRACTOR SHALL VISIT THE PROJECT SITE BEFORE SUBMITTING HIS BID. SUBMITTING
A BONA FIDE BID SHALL INCLUDE VERIFICATION AND ACKNOWLEDGEMENT BY THE
CONTRACTOR THAT A SITE VISIT WAS PERFORMED, THE EXISTING CONDITIONS IN WHICH THE
WORK IS TO BE PERFORMED ARE UNDERSTOOD BY THE CONTRACTOR, AND THE BID INCLUDES
ALL ALLOWANCES (ADDITIVE AND DEDUCTIVE) TO COMPLETE IN DETAIL ALL THE WORK
INCLUDED IN THE CONTRACT DOCUMENTS FOR THE PRICE INCLUDED IN THE BID AND WITHIN
THE TIME ALLOTED IN THE CONSTRUCTION SCHEDULE. THE CONTRACTOR SHALL NOT BE
GRANTED ANY EXTENSIONS OF TIME OR INCREASE IN PAYMENT DUE TO ANY CLAIM BY THE
CONTRACTOR REGARDING ANY EXISTING CONDITION.
2. THE DEFINITION OF "WORK" IS:
THE CONSTRUCTION AND SERVICES REQUIRED BY THE CONTRACT DOCUMENTS, INCLUDING
BUT NOT LIMITED TO: LABOR, MATERIALS, EQUIPMENT, SUPERVISION, ETC, REQUIRED TO
PROVIDE A COMPLETE INSTALLATION MEETING ALL REGULATORY REQUIREMENTS READY FOR
OCCUPANCY.
THE WORK IS LIMITED TO THE SCOPE OF WORK INDICATED ON THE CONTRACT DOCUMENTS
AND TO THE "LIMITS OF CONSTRUCTION" INDICATED. ANY CHANGED TO THE SCOPE OF WORK
OR WORK BEYOND THE LIMITS OF CONSTRUCTION REQUIRES PRIOR APPROVAL BY THE
ARCHITECT. CONTRACTOR SHALL SUBMIT WRITTEN NOTIFICATION TO THE ARCHITECT AND
OBTAIN APPROVAL FROM THE ARCHITECT BEFORE BEGINNING ANY WORK NOT INCLUDED IN
THE SCOPE OF WORK. ANY ADDITIONAL WORK INSTALLED WITHOUT PRIOR WRITTEN APPROVAL
SHALL BE AT THE CONTRACTOR'S SOLE RISK AND EXPENSE.
3. THE CONTRACTOR SHALL OBTAIN PERMITS AND PERMISSIONS FROM ALL REGULATORY
AGENCIES HAVING JURISDICTION OVER THE WORK. CONTRACTOR SHALL SUBMIT COPIES OF
ALL REGULATORY PERMISSIONS AND PERMITS TO THE ARCHITECT.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COMPLIANCE WITH ALL REGULATORY
REQUIREMENTS, CODES, ORDINANCES, ETC, INCLUDING APPLICATION, MEETINGS, COSTS,
INSPECTIONS, AND POSTING, UNLESS NOTED OTHERWISE. THE CONTRACTOR SHALL NOT
COMMENCE WORK UNTIL ALL REQUIRED REGULATORY REQUIREMENTS, INCLUDING BUT NOT
LIMITED TO REQUIRED "PERMITS FOR CONSTRUCTION", ARE COMPLETED.
5. CRITICAL PATH CONSTRUCTION SCHEDULE: WITHIN 5 DAYS AFTER EXECUTION OF THE OWNER-
CONTRACTOR AGREEMENT, THE CONTRACTOR SHALL SUBMIT A DETAILED CRITICAL PATH
CONSTRUCTION SCHEDULE FOR THE PROJECT TO THE OWNER AND THE ARCHITECT. THE
CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANTICIPATED DELAYS IN THE WORK FOR ANY
REASON.
6. PROJECT SIGN OR BULLETIN BOARD: PREPARE PROJECT IDENTIFICATION AND PERMIT POSTING AS REQUIRED BY LOCAL, MUNICIPALITY, STATE, AND FEDERAL LAW. INSTALL WHERE DIRECTED
BY THE ARCHITECT OR BUILDING MANAGEMENT. DO NOT PERMIT INSTALLATION OF
UNAUTHORIZED SIGNS.
7. PROVIDE 72 HOURS ADVANCE NOTICE TO OWNER FOR ACCESS TO AREAS OUTSIDE OF THE
SCOPE OF WORK. ACCESS SHALL BE COORDINATED WITH THE OWNER. ALL WORK OUTSIDE THE
SCOPE OF WORK SHALL BE SCHEDULED FOR NON BUSINESS HOURS. PENETRATIONS THROUGH
EXISTING FLOOR ASSEMBLIES AND FIRE RATED PARTITIONS AND WALLS SHALL BE SEALED
WITH UL LISTED AND ARCHITECT APPROVED "FIRE STOP" ASSEMBLIES. CONTRACTOR SHALL
SUBMIT PROPOSED METHOD OF SEALING TO THE ARCHITECT FOR APPROVAL BEFORE
INSTALLING.
8. OWNER SUPPLIED FURNISHINGS AND EQUIPMENT: CONTRACTOR SHALL NOT PROCEED WITH
ANY WORK REQUIRING COORDINATION WITH OWNER SUPPLIED FURNISHINGS AND EQUIPMENT
UNTIL SUBMITTALS HAVE BEEN RETURNED AFTER REVIEW BY THE OWNER AND ARCHITECT.
CONTRACTOR SHALL COORDINATE AND ACCOMMODATE ALL OWNER SUPPLIED FURNISHINGS
AND EQUIPMENT INDICATED IN THE CONTRACT DOCUMENTS INTO THE WORK. CONTRACTOR
SHALL BE RESPONSIBLE FOR ALL COSTS RESULTING FROM THE CONTRACTOR'S FAILURE TO
OBTAIN REVIEWS.
9. THE CONTRACTOR SHALL NOT KNOWINGLY PURCHASE OR ORDER ANY MATERIAL OR
EQUIPMENT WHOSE DELIVERY SCHEDULE COULD CAUSE THE PROJECT TO BE DELAYED.
10. CLEANING: CONTRACTOR SHALL PROVIDE DAILY AND FINAL CLEANING. CONDUCT CLEANING
AND WASTE-REMOVAL OPERATIONS TO COMPLY WITH LOCALLAWS AND ORDINANCES AND
FEDERAL AND LOCAL ENVIRONMENTAL AND ANTIPOLLUTION REGULATIONS. EMPLOY
EXPERIENCED WORKERS OR PROFESSIONAL CLEANERS FOR FINAL CLEANING. CLEAN EACH
SURFACE OR UNIT TO CONDITION EXPECTED IN AN AVERAGE COMMERCIAL BUILDING CLEANING
AND MAINTENANCE PROGRAM. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.
11. PROJECT CLOSE-OUT: THE CONTRACTOR SHALL COMPLETE THE FOLLOWING BEFORE TURNING
THE PROJECT OVER TO THE OWNER:
A. PREPARE A LIST OF ITEMS TO BE COMPLETED AND CORRECTED (PUNCH LIST), THE VALUE
OF ITEMS ON THE LIST, AND REASONS WHY THE WORK IS NOT COMPLETE.
B. ADVISE OWNER OF PENDING INSURANCE CHANGEOVER REQUIREMENTS (IF ANY.)
C. SUBMIT SPECIFIC WARRANTIES, WORKMANSHIP BONDS, MAINTENANCE SERVICE
AGREEMENTS, FINAL CERTIFICATIONS, AND SIMILAR DOCUMENTS.
D. OBTAIN AND SUBMIT RELEASES PERMITTING OWNER UNRESTRICTED USE OF THE WORK
AND ACCESS TO SERVICES AND UTILITIES. INCLUDE OCCUPANCY PERMITS, OPERATING
CERTIFICATES, AND SIMILAR RELEASES.
E. PREPARE AND SUBMIT PROJECT RECORD DOCUMENTS, OPERATION AND MAINTENANCE
MANUALS, AND SIMILAR FINAL RECORD INFORMATION.
F. DELIVER TOOLS, SPARE PARTS, EXTRA MATERIALS, AND SIMILAR ITEMS TO LOCATION
DESIGNATED BY OWNER. LABEL WITH MANUFACTURER'S NAME AND MODEL NUMBER
WHERE APPLICABLE.
G. MAKE FINAL CHANGEOVER OF PERMANENT LOCKS AND DELIVER KEYS TO OWNER. ADVISE
OWNER'S PERSONNEL OF CHANGEOVER IN SECURITY PROVISIONS.
H. COMPLETE STARTUP TESTING OF SYSTEMS.
I. SUBMIT TEST/ADJUST/BALANCE RECORDS.
J. TERMINATE AND REMOVE TEMPORARY FACILITIES FROM PROJECT SITE, ALONG WITH
MOCKUPS, CONSTRUCTION TOOLS, AND SIMILAR ELEMENTS.
K. COMPLETE FINAL CLEANING REQUIREMENTS, INCLUDING TOUCH UP PAINTING.
L. TOUCH UP AND OTHERWISE REPAIR AND RESTORE MARRED EXPOSED FINISHES TO
ELIMINATE VISUAL DEFECTS.
THIS DOCUMENT AND THE INFORMATION
CONTAINED THEREIN IS THE SOLE
POSSESSION OF STUDIO DETROIT AND
SHALL NOT BE ALTERED OR MODIFIED
WITHOUT THE EXPRESS WRITTEN
PERMISSION OF STUDIO DETROIT. ANY
MODIFICATION OR ALTERATION THEREOF
SHALL INDEMNIFY AND HOLD HARMLESS
STUDIO DETROIT OF ALL EXPENSES, CLAIMS
AND/OR LIABILITY RESULTING FROM SUCH
MODIFICATIONS OR ALTERATIONS.
� 2026 STUDIO DETROIT LLC
DO NOT SCALE DRAWINGS
2040 PARK AVENUE, SUITE 200
DETROIT, MICHIGAN 48226
STUDIO-DETROIT.COM
ISSUED
DRAWN
CHECKED
SEAL
CLIENT
PROJECT
PROJECT MANAGER
PROJECT NO.
191 PINE TREE LANE
SANDUSKY, MI 48471
SANDUSKY
COMMUNITY SCHOOLS
STORAGE BUILDING
TS1.2
SMB
PNP
SYMBOLS +
ABBREVIATIONS
06.25.26 BID / PERMIT
125 DAVIS STREET
SANDUSKY, MI 48471
SANDUSKY
COMMUNITY SCHOOLS
PETER PENTESCU
PETE@STUDIO-DETROIT.COM
586.747.9717
26031
TYP 1/2" = 1'-0"
@SIDE APPROACH
DOOR CLEARANCE DIAGRAM
TYP 1/2" = 1'-0"
@FRONT APPROACH
DOOR CLEARANCE DIAGRAM
TYP 1/2" = 1'-0"
@NEW BUILDINGS/FACILITIES
WHEELCHAIR TURNING SPACE
CODE STUDY LEGEND
X
ROOM
NAME
DISTANCE TO EXIT
(U) USE
X
OCCUPANT LOAD
TOTAL EXIT LOAD
CODE ANALYSIS : NON-SPRINKLERED BUILDING
1. OCCUPANCY :
2021 MICHIGAN BUILDING CODE TYPE TABLE 508.4 : REQUIRED OCCUPANCY SEPARATION
A. SECTION 312.1 UTILITY GROUP - U NONE REQUIRED
2. CONSTRUCTION TYPE / FIREPROOFING :
2021 MICHIGAN BUILDING CODE TYPE
A. TABLE 601 / 705.5 - FIRE-RESISTANCE RATING REQUIREMENTS V-B (NON-SPRINKLERED)
BUILDING ELEMENT FIRE RESISTANCE
(*REFER TO TABLE 601/705.5 FOR
CONDITIONAL REQUIREMENTS)
PRIMARY STRUCTURAL FRAME 0 HR
BEARING WALLS - EXTERIOR 0 HR
BEARING WALLS - INTERIOR 0 HR
NON-BEARING WALLS - EXTERIOR 0 HR (>10FT;<30FT)
1 HR (>5FT;<10FT)
NON-BEARING WALLS - INTERIOR 0 HR*
FLOOR CONSTRUCTION & SECONDARY MEMBERS 0 HR
ROOF CONSTRUCTION & SECONDARY MEMBERS 0 HR* / CLASS C (TABLE 1505.1)
B. TABLE 705.8 - MAXIMUM AREA OF EXTERIOR WALL OPENINGS
CLASSIFICATION OF OPENING FIRE SEPARATION DISTANCE
*REFER TO TABLE 705.8 FOR
CONDITIONAL REQUIREMENTS)
UNPROTECTED / SPRINKLERED 30 FEET OR GREATER = NOT
REQUIRED
PROTECTED 30 FT OR GREATER = NOT
REQUIRED
C. TABLE 716.1(2) - FIRE DOOR AND FIRE SHUTTER FIRE PROTECTION RATINGS
TYPE OF ASSEMBLY REQ'D FIRE RATING MIN. FIRE DOOR / FIRE
SHUTTER RATING
FIRE WALLS / FIRE BARRIERS > 1 HR 4 HR / 3 HR 3 HR
2 HR / 1-1/2 HR 1-1/2 HR
FIRE BARRIERS OF 1 HR
SHAFT, EXIT ENCLOSURE &
EXIT PASSAGEWAY WALLS 1 HR 1 HR
OTHER FIRE BARRIERS 1 HR 3/4 HR
FIRE PARTITIONS
CORRIDOR WALLS 1 HR / 1/2 HR 1/3 HR
OTHER FIRE PARTITIONS 1 HR 3/4 HR
OTHER FIRE PARTITIONS 1/2 HR 1/3 HR
EXTERIOR WALLS 3 HR / 2 HR 1-1/2 HR
1 HR 3/4 HR
SMOKE BARRIERS 1 HR 1/3 HR
3. GENERAL BUILDING HEIGHT AND AREAS :
4. OCCUPANCY / EGRESS WIDTH / EXIT QUANTITY :
2021 MICHIGAN BUILDING CODE
A. TABLE 504.3, TABLE 504.4, AND TABLE 506.2 - ALLOWABLE HEIGHT AND BUILDING AREAS
GROUP TYPE OF CONSTRUCTION ALLOWABLE BLDG HT / AREA
*REFER TO TABLE 506.2 FOR
CONDITIONAL REQUIREMENTS)
U V-B / NS 1 STORIES (40 FT)* / 5,500 SF PER FLOOR
B. ACTUAL BUILDING AREAS
GROUP TOTAL
U - UTILITY 3,200 GSF
2021 MICHIGAN BUILDING CODE
A. TABLE 1004.5 - MAXIMUM FLOOR AREA ALLOWANCE (SEE PLAN FOR FACTORED COUNT)
USE (1ST FLOOR) AREA SF / OCCUPANT OCCUPANTS
STORAGE UNITS (STORAGE) 3,066 1/300 12
TOTAL BUILDING OCCUPANTS 12
B. SECTION 1005 - EGRESS WIDTH PER OCCUPANT SERVED
REQUIRED REQUIRED
OCCUPANCY / FLOOR STAIRWAY FACTOR OTHER COMPONENT STAIR WIDTH OTHER WIDTH
1ST FLOOR = 12 0.3 0.2 N/A 2.4 INCHES
- ACTUAL EXIT WIDTH PROVIDED: EACH UNIT IS PROVIDED WITH A MANUAL ROLL-UP DOOR. SPACE IS
NOT INTENDED FOR OCCUPANCY
C. TRAVEL DISTANCES
TABLE / SECTION ITEM DISTANCE ALLOWED
TABLE 1006.2.1 COMMON PATH OF TRAVEL U - UTILITY = 100 FT
TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCE U - UTILITY = 300 FT
SECTION 1020.5 DEAD END CORRIDOR LENGTH U - UTILITY = 50 FT
D. TABLE 803.13 - WALL AND CEILING FINISHES (NON-SPRINKLERED)
VERTICAL EXITS EXIT ACCESS CORR'S ROOMS AND
GROUP AND PASSAGEWAYS AND OTHER EXITWAYS ENCLOSED SPACES
U NO RESTRICTIONS NO RESTRICTIONS NO RESTRICTIONS
5. FIRE PROTECTION SYSTEMS:
2021 MICHIGAN BUILDING CODE
A. SECTION 903 - AUTOMATIC SPRINKLER SYSTEMS
U - UTILITY - NO SPRINKLER SYSTEM REQUIRED
B. SECTION 907 - FIRE ALARM AND DETECTION SYSTEMS
U - UTILITY - NO ALARM SYSTEM REQUIRED
6. ENERGY COMPLIANCE:
2021 MICHIGAN ENERGY CODE
A. SECTION C402.1.1 - LOW-ENERGY BUILDINGS AND GREENHOUSES
THE FOLLOWING LOW-ENERGY BUILDINGS, OR PORTIONS THEREOF SEPARATED FROM THE REMAINDER OF THE BUILDING BY BUILDING THERMAL ENVELOPE ASSEMBLIES COMPLYING WITH THIS SECTION, SHALL
BE EXEMPT FROM THE BUILDING THERMAL ENVELOPE PROVISIONS OF SECTIONS C402.
1. THOSE WITH A PEAK DESIGN RATE OF ENERGY USAGE LESS THAN 3.4 BTU/H x SF - or - 1.0 WATT
PER SF OF FLOOR AREA FOR SPACE CONDITIONING PURPOSES.
2. THOSE THAT DO NOT CONTAINED CONDITIONED SPACE.
252 SF
STORAGE 1
1/300
257 SF
STORAGE 2
1/300
257 SF
STORAGE 3
1/300
257 SF
STORAGE 4
1/300
257 SF
STORAGE 5
1/300
252 SF
STORAGE 6
1/300
252 SF
STORAGE 7
1/300
257 SF
STORAGE 8
1/300
257 SF
STORAGE 9
1/300
257 SF
STORAGE 10
1/300
257 SF
STORAGE 11
1/300
252 SF
STORAGE 12
1/300
T R
A V
E L
D
IS
T A
N C
E
GENERAL CODE STUDY PLAN NOTES:
1. ALL CONSTRUCTION SHALL BE PROTECTED AS INDICATED ON THE LIFE SAFETY DRAWINGS AND
CODE SUMMARY. IF A DISCREPANCY EXISTS BETWEEN THE INFORMATION CONTAINED ON
THESE SHEETS AND ON THE DETAILS, OR ELSEWHERE IN THE DOCUMENTS, CONSULT
ARCHITECT.
2. REFER TO LEGEND FOR RATING AND TYPE OF WALL SEPARATION REQUIRED. WALL TYPE FIRE
RESISTIVE RATINGS ARE TO BE CONTINUOUS FOR THE ENTIRE LENGTH AND HEIGHT OF THE
PARTITION.
3. FLOOR / CEILING AND ROOF / CEILING RATINGS ARE AS INDICATED ON THE CODE SUMMARY.
CONTINUITY OF PROTECTION SHALL BE ASSUMED FOR THE ENTIRE LENGTH AND HEIGHT OF
CONSTRUCTION INDICATED.
4. REFER TO DETAIL DRAWINGS FOR U.L. DESIGN NUMBER(S) AT ALL RATED CONSTRUCTION.
5. ALL RECESSED CABINETS, PANELS, AND BOXES LOCATED IN FIRE-RATED WALLS SHALL BE
INSTALLED TO MAINTAIN FIRE-RATED CONSTRUCTION.
THIS DOCUMENT AND THE INFORMATION
CONTAINED THEREIN IS THE SOLE
POSSESSION OF STUDIO DETROIT AND
SHALL NOT BE ALTERED OR MODIFIED
WITHOUT THE EXPRESS WRITTEN
PERMISSION OF STUDIO DETROIT. ANY
MODIFICATION OR ALTERATION THEREOF
SHALL INDEMNIFY AND HOLD HARMLESS
STUDIO DETROIT OF ALL EXPENSES, CLAIMS
AND/OR LIABILITY RESULTING FROM SUCH
MODIFICATIONS OR ALTERATIONS.
� 2026 STUDIO DETROIT LLC
DO NOT SCALE DRAWINGS
2040 PARK AVENUE, SUITE 200
DETROIT, MICHIGAN 48226
STUDIO-DETROIT.COM
ISSUED
DRAWN
CHECKED
SEAL
CLIENT
PROJECT
PROJECT MANAGER
PROJECT NO.
191 PINE TREE LANE
SANDUSKY, MI 48471
SANDUSKY
COMMUNITY SCHOOLS
STORAGE BUILDING
TS1.3
SMB
PNP
CODE STUDY
06.25.26 BID / PERMIT
125 DAVIS STREET
SANDUSKY, MI 48471
SANDUSKY
COMMUNITY SCHOOLS
PETER PENTESCU
PETE@STUDIO-DETROIT.COM
586.747.9717
26031
N
1/8" = 1'-0"
FIRST FLOOR - CODE STUDY
GENERAL FOUNDATION PLAN NOTES:
1. THIS DRAWING IS DIAGRAMMATIC AND SHOULD BE USED TO DETERMINE THE DESIGN INTENT.
THE CONTRACTOR IS RESPONSIBLE FOR THE COMPLETE SET OF WORK AS INDICATED AND
SHALL FIELD VERIFY ALL WORK, COORDINATE ALL DRAWINGS / NEW WORK AND SHALL NOTIFY
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DOCUMENTS BEFORE PROCEEDING.
FAILURE TO DO SO WILL RESULT IN THE CONTRACTOR TAKING FULL RESPONSIBILITY AND
LIABILITY FOR SAID DISCREPANCIES.
2. ALL DIMENSIONS SHALL BE COORDINATED WITH THE ARCHITECTURAL FLOOR PLAN DRAWINGS (A1.1)
SCOPE OF WORK TO INCLUDE:
3. PROVIDE SLEEVES FOR ALL PIPING AND ELECTRICAL CONDUIT; COORDINATE WITH PLUMBING
AND ELECTRICAL.
4. PROVIDE ALL FOUNDATIONS REQ'D FOR SITE ELEMENTS INCLUDING: BOLLARDS, GATES, ETC.
FOUNDATION PLAN KEY NOTES:
(TYPICAL THIS SHEET ONLY)
1 CONCRETE APRON w/ 6x6 - W2.1xW2.1 W.W.F. (ALTERNATE)
2 4" CONCRETE SLAB REINFORCED w/ 6x6 - W1.4xW1.4 W.W.F. PLACED IN UPPER THIRD OF
SLAB TYPICAL
3 CONTINUOUS WALL FOOTING w/ 2 - #5 REINFORCING BARS; CONT. TOP AND BOTTOM
4 6" CMU BASE COURSE; GROUT SOLID
5 THICKENED SLAB w/ 2 - #5 REINFORCING BARS' CONT. BOTTOM
Y'
X'
1'-4" 78'-1 13/16" 1'-4"
'-4
'-2
/8
'-4
'-1
/8
80'-9 13/16"
TYP
TYP
5 5/8"
8" 8"
TYP
TYP
A3.1
A3.1
'-0
'-0
TYP
GENERAL ROOF PLAN NOTES:
1. REFER TO SHEET A1.1 FOR ADDITIONAL GENERAL NOTE REQUIREMENTS.
2. WOOD BLOCKING SHALL BE SET FLUSH WITH THE TOP LAYER OF INSULATION, WHICH SHALL
INCLUDE THE COMBINED THICKNESS OF MULTIPLE LAYERS OF RIGID INSULATION, INCLUDING
TAPERED INSULATION, FIBERBOARD, AND SADDLES.
3. ROOF SLOPE TO BE 1/4" PER FOOT MINIMUM; TYPICAL. CRICKETS TO BE 1/2" PER FOOT SLOPE
MINIMUM.
4. PROVIDE EXPANSION JOINT IN ROOF INSULATION AND MEMBRANE PER MANUFACTURER
INSTRUCTIONS.
5. CURBS AND ACCESSORIES FOR THE FOLLOWING ITEMS SHALL BE FURNISHED BY OTHER
TRADES FOR INSTALLATION BY ARCHITECTURAL TRADES:
A. ROOF MOUNTED EQUIPMENT
B. ROOF MOUNTED PIPING
C. PENETRATIONS FOR PIPING, POWER FEEDS, ETC.
6. COORDINATE ROOF PENETRATIONS WITH OTHER TRADES; INCLUDING STRUCTURAL,
MECHANICAL AND ELECTRICAL.
ROOF PLAN KEY NOTES:
(TYPICAL THIS SHEET ONLY)
1 JENSEN BRIDGE AND SUPPLY NEW STANDING SEAM / METAL PANEL ROOF w/ SNOW
GUARDS (OR EQUAL) ON ICE AND WATER SHIELD ON 3/4" PLYWOOD SUBSTRATE ROOF
SYSTEM; COLOR AND PROFILE AS SELECTED BY OWNER
2 STEEL GUTTER AND DOWNSPOUTS; COLOR AS SELECTED BY OWNER
3 SNOW GUARD BY METAL PANEL SUPPLIER
4 METAL FASCIA TRIM TO MATCH ROOF
THIS DOCUMENT AND THE INFORMATION
CONTAINED THEREIN IS THE SOLE
POSSESSION OF STUDIO DETROIT AND
SHALL NOT BE ALTERED OR MODIFIED
WITHOUT THE EXPRESS WRITTEN
PERMISSION OF STUDIO DETROIT. ANY
MODIFICATION OR ALTERATION THEREOF
SHALL INDEMNIFY AND HOLD HARMLESS
STUDIO DETROIT OF ALL EXPENSES, CLAIMS
AND/OR LIABILITY RESULTING FROM SUCH
MODIFICATIONS OR ALTERATIONS.
� 2026 STUDIO DETROIT LLC
DO NOT SCALE DRAWINGS
2040 PARK AVENUE, SUITE 200
DETROIT, MICHIGAN 48226
STUDIO-DETROIT.COM
ISSUED
DRAWN
CHECKED
SEAL
CLIENT
PROJECT
PROJECT MANAGER
PROJECT NO.
191 PINE TREE LANE
SANDUSKY, MI 48471
SANDUSKY
COMMUNITY SCHOOLS
STORAGE BUILDING
A1.0
SMB
PNP
ARCHITECTURAL
FOUNDATION PLAN
06.25.26 BID / PERMIT
125 DAVIS STREET
SANDUSKY, MI 48471
SANDUSKY
COMMUNITY SCHOOLS
PETER PENTESCU
PETE@STUDIO-DETROIT.COM
586.747.9717
26031
N
1/8" = 1'-0"
ARCHITECTURAL FOUNDATION PLAN
N
ARCHITECTURAL ROOF PLAN
GFCI GFCI GFCI
GFCI GFCI GFCI
A3.1
A3.1
80'-0"
'-0
2'-11 1/8" 8'-0" 5'-2 3/4" 8'-0" 5'-2 3/4" 8'-0" 5'-2 3/4" 8'-0" 5'-2 3/4" 8'-0" 5'-2 3/4" 8'-0" 2'-11 1/8"
STORAGE 1
STORAGE 2
STORAGE 3
STORAGE 4
STORAGE 5
STORAGE 6
STORAGE 7
STORAGE 8
STORAGE 9
STORAGE 10
STORAGE 11
STORAGE 12
H
W
OD1
8' - 0"
8' - 0" H
W
OD2
8' - 0"
8' - 0" H
W
OD3
8' - 0"
8' - 0" H
W
OD4
8' - 0"
8' - 0" H
W
OD5
8' - 0"
8' - 0" H
W
OD6
8' - 0"
8' - 0"
H
W
OD7
8' - 0"
8' - 0" H
W
OD8
8' - 0"
8' - 0" H
W
OD9
8' - 0"
8' - 0" H
W
OD10
8' - 0"
8' - 0" H
W
OD11
8' - 0"
8' - 0" H
W
OD12
8' - 0"
8' - 0"
12'-8 11/16" 6 1/8" 12'-8 5/8" 6 1/8" 12'-8 5/8" 6 1/8" 12'-8 5/8" 6 1/8" 12'-8 5/8" 6 1/8" 12'-8 11/16"
'-1
/8
/4
'-1
/8
2'-11 1/8" 8'-0" 5'-2 3/4" 8'-0" 5'-2 3/4" 8'-0" 5'-2 3/4" 8'-0" 5'-2 3/4" 8'-0" 5'-2 3/4" 8'-0" 2'-11 1/8"
TYP
TYP
TYP
TYP
TYP
GENERAL FLOOR PLAN NOTES:
1. THIS DRAWING IS DIAGRAMMATIC AND SHOULD BE USED TO DETERMINE THE DESIGN INTENT.
THE CONTRACTOR IS RESPONSIBLE FOR THE COMPLETE SET OF WORK AS INDICATED AND
SHALL FIELD VERIFY ALL WORK, COORDINATE ALL DRAWINGS / NEW WORK AND SHALL NOTIFY
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DOCUMENTS BEFORE PROCEEDING.
FAILURE TO DO SO WILL RESULT IN THE CONTRACTOR TAKING FULL RESPONSIBILITY AND
LIABILITY FOR SAID DISCREPANCIES.
2. CONTRACTOR IS RESPONSIBLE FOR SECURING ALL PERMITS REQUIRED BY LOCAL AUTHORITIES
HAVING JURISDICTION.
3. CONTRACTOR SHALL SUBMIT TO THE LOCAL AUTHORITY HAVING JURISDICTION, DETAILED
PLANS FOR SPRINKLER SYSTEM WORK, AND ANY ADDITIONAL WORK REQUIRED FOR FIRE ALARM
AND SMOKE DETECTION NOT ALREADY INCLUDED IN THESE DOCUMENTS.
4. ALL DIMENSIONS ARE SHOWN FROM FINISH FACE TO FINISH FACE OF PARTITION UNLESS
NOTED OTHERWISE; AT TILE WALL LOCATIONS, TILE THICKNESS IS ASSUMED TO BE 1/2".
5. ALL DOORS IN GYP BOARD PARTITIONS TO BE 2" FROM ADJACENT WALL TO FRAME UNLESS
NOTED OTHERWISE.
6. ALL WOOD, INCLUDING BLOCKING, USED ON THE PROJECT SHALL BE FIRE RETARDANT
TREATED.
7. ALL WORK SHALL BE DONE IN ACCORDANCE WITH ALL LOCAL, STATE, COUNTY CODE
REGULATIONS, O.S.H.A., AND THE AMERICAN WITH DISABILITIES ACT (ADA). REFER TO THE
CODE PLAN FOR MORE INFORMATION AND ADA REQUIRED CLEARANCES.
8. PROVIDE POSITIVE SLOPE TO ALL FLOOR DRAINS WHILE KEEPING FLOOR LEVEL AT WALL BASE
CONDITION.
9. THE CONTRACTOR SHALL PROVIDE AND INSTALL WALL REINFORCING FOR INSTALLATION OF
ACCESSORIES, COAT RACKS, CABINETS, COUNTERTOPS, AND OTHER WALL MOUNTED ITEMS.
10. CLEAN AND REPAIR ALL EXISTING FLOOR FINISHES AS NECESSARY.
11. PROVIDE CONTROL JOINTS IN GYPSUM BOARD PARTITIONS AT 24'-0" O.C. MAXIMUM AND AS
INDICATED IN THE CONTRACT DOCUMENTS.
12. COORDINATE WITH OWNER'S EQUIPMENT SUPPLIER FOR INSTALLATION REQUIREMENTS /
LOCATIONS OF FLOOR / WALL / CEILING MOUNTED ITEMS; IE. CAMERAS, TV'S, SPEAKERS,
SENSORS, SECURITY WIRING, ETC.
13. CONTRACTOR SHALL CONDUCT A ROUGH ELECTRICAL INSPECTION WITH OWNER, PRIOR TO
ENCLOSING WALLS, FOR THE PURPOSE OF CONFIRMING ALL J-BOX LOCATIONS FOR POWER,
DATA, VOICE, SWITCH, THERMOSTAT, ETC.
14. A TACTILE SIGN STATING 'EXIT' AND COMPLYING WITH ICC-A117.1 SHALL BE PROVIDED ADJACENT TO EACH DOOR TO AN 'AREA OF REFUGE', AN EXTERIOR AREA FOR ASSISTED RESCUE, AN EXIT STAIRWAY, AN EXIT RAMP, AN EXIT PASSAGEWAY, AND THE EXIT DISCHARGE.
15. PROVIDE PERMANENT 2-INCH HIGH LETTERING MARKING AND IDENTIFICATION AT ALL FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS, SMOKE PARTITIONS OR ANY OTHER
WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS AT 30 FEET MAXIMUM
HORIZONTAL INTERVALS, MINIMUM 2 LOCATIONS EACH WALL, IN ACCESSIBLE CONCEALED
FLOOR, FLOOR-CEILING, OR ATTIC SPACES PER CODE.
16. ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE FIRE CAULKED/TAPED. SEAL
ALL UTILITY PENETRATIONS AS FOLLOWS:
A. FIRE RATED FLOORS: THROUGH PENETRATION FIRE STOPPING SYSTEM, MATCH FIRE
RATING OF THE FLOOR ASSEMBLY
B. NON-RATED FLOORS: THROUGH PENETRATION FIRE STOPPING SYSTEM, ONE HOUR FIRE
RATED.
C. FIRE RATED WALLS: THROUGH PENETRATION FIRE STOPPING SYSTEM, MATCH FIRE
RATING OF THE WALL
D. NON-RATED WALLS: FILL VOIDS / ANNULAR SPACES WITH MINERAL WOOL INSULATION
AND APPLY ACOUSTICAL SEALANT TO BOTH SIDES OF WALL. EXCEPTIONS: CONDUIT
SLEEVES AND TRAYS FOR LOW VOLTAGE CABLES AND ELECTRICAL BUSWAYS SHALL
RECEIVE A ONE HOUR THROUGH PENETRATION FIRE STOPPING SYSTEM.
17. CONTRACTOR TO COORDINATE LOCATION OF EXISTING AND NEW FIRE EXTINGUISHERS: NEW
FIRE EXTINGUISHER COMPARTMENTS WITH FIRE EXTINGUISHERS TO BE SEMI-RECESSED
(SHOULD NOT EXCEED 4" PROTRUSION FROM WALL FACE). LOCATION AND DIMENSIONS MUST
MEET ACCESSIBLE AND LOCAL CODES. MINIMUM OF ONE (1) FIRE EXTINGUISHER FOR EVERY 75 FEET DIAMETER RADIUS VERIFY WITH LOCAL OFFICIAL. CONFIRM LOCATIONS WITH ARCHITECT
PRIOR TO INSTALLATION.
18. UPON COMPLETION, IT IS THE OWNER RESPONSIBILITY FOR PROVIDING POSTED ASSEMBLY
AREAS NOTING OCCUPANT LOADS ON A PLACARD AS APPROVED BY THE AUTHORITY HAVING
JURISDICTION. (CONTRACTOR TO COORDINATE)
FLOOR PLAN KEY NOTES:
(TYPICAL THIS SHEET ONLY)
6 LINE OF SOFFIT / ROOF OVERHANG ABOVE
1 CONCRETE APRON w/ 6x6 - W2.1xW2.1 W.W.F. (ALTERNATE)
5 HEADER JAMBS - 2 JACK STUDS AND 1 KING STUD EA. SIDE
4 MANUAL ROLL UP DOOR w/ LOCKABLE HASP ON EXTERIOR; OVERHEAD DOOR 600 SERIES OR
EQUAL
3 EXTERIOR WALL CONSTRUCTION:
CORRUGATED METAL PANEL
AIR / MOISTURE BARRIER
5/8" THK EXT. GRADE SHEATHING
2x6 WD STUDS @ 16" O.C.
5/8" THK PLYWOOD SHEATHING
2 INTERIOR WALL CONSTRUCTION:
2x6 WD STUDS @ 16" O.C.
5/8" THK. PLYWOOD SHEATHING (2-SIDED AT BACK WALL
OF UNITS)
7 NEW GFCI, WET PROTECTED EXTERIOR OUTLET MOUNTED AT 18" AFF; POWER TO BE RUN
FROM ADJACENT BUILDING - CONFIRM POWER CAPACITY AND AVAILABLE CIRCUITS
'-1
/2
(3) 2x12
TYP
TYP
1 TYP
(3) 2x12 (3) 2x12 (3) 2x12 (3) 2x12(3) 2x12
(3) 2x12 (3) 2x12 (3) 2x12 (3) 2x12 (3) 2x12 (3) 2x12
MP-3
MP-3
MESH
MESH
GENERAL REFLECTED CEILING PLAN NOTES:
1. LIGHT FIXTURES SHALL BE LOCATED IN THE CENTER OF THE ROOM OR SPACE, UNLESS NOTED
OTHERWISE.
2. CONTRACTOR TO CENTER ALL CEILING MOUNTED ITEMS (i.e.. RECESSED LIGHT FIXTURES, SMOKE DETECTORS, FIRE SUPPRESSION HEADS, ETC.) WITHIN THE ASSOCIATED CEILING TILE
AS SHOWN. COORDINATE FINAL LOCATION WITH THE APPROPRIATE MECHANICAL,
ELECTRICAL, FIRE ALARM, AND FIRE SUPPRESSION DRAWINGS AS REQUIRED.
3. ELECTRICAL CONTRACTOR SHALL COORDINATE/CONFIRM ALL LIGHT SWITCH, PHONE, DATA,
AND ELEC. OUTLETS, w/ TENANT. - ELEC. CONT. SHALL RECEIVE FINAL WRITTEN APPROVAL OF
ALL LOCATIONS PRIOR TO ENCLOSING GYP. BD. WALLS.
4. REFER TO WALL TYPES FOR WALLS THAT PENETRATE CEILINGS.
5. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING GRILLS & DIFFUSERS, AND
IS ALSO RESONSIBLE FOR ALL MODIFICATIONS REQ. TO EXISTING SYSTEM.
6. REFER TO MECHANICAL ENGINEERING DRAWINGS FOR QUANTITY AND SIZE OF AIR SUPPLY
DIFFUSERS, AIR RETURN, AND EXHAUST GRILLES. REFER TO ARCHITECTURAL REFLECTED
CEILING PLANS FOR EXACT PLACEMENT. NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO
INSTALLATION.
7. IN THE EVENT OF CONFLICTS BETWEEN THE REFLECTED CEILING PLANS AND THE
CORRESPONDING DRAWINGS OF OTHER DISCIPLINES, THE CONTRACTOR SHALL BRING THE
CONFLICT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION PRIOR TO
INSTALLATION.
8. EXIT SIGNS SHALL BE CENTERED IN CORRIDORS AND LOCATED A DISTANCE OF 1'-0" FROM
WALLS (TO CENTER LINE OF FIXTURE) UNLESS NOTED OTHERWISE. VERIFY EXIT SIGN
LOCATIONS WITH THE AUTHORITY HAVING JURISDICTION PRIOR TO INSTALLATION.
9. ELECTRICAL CONTRACTOR TO VERIFY QUANTITY AND LOCATION OF ALL EXISTING LIGHT
FIXTURES TO BE REPLACED.
10. REFER TO DIMENSIONS ON REFLECTED CEILING PLAN TO LOCATE / LAYOUT CEILING GRID AND
LIGHT FIXTURES.
11. COORDINATE LIGHT FIXTURE LOCATIONS WITH ALL OTHER ABOVE CEILING WORK. LIGHT
FIXTURE LOCATIONS SHALL TAKE PRECEDENCE OVER ALL SUCH OTHER WORK REGARDLESS OF
WORK SEQUENCE. CONTRACTOR SHALL PREPARE A COORDINATION DRAWING TO COORDINATE
PLACEMENT OF ABOVE CEILING WORK, INCLUDING, BUT NOT LIMITED TO, LIGHT FIXTURES,
MECHANICAL EQUIPMENT, DUCTWORK, SPRINKLER HEADS, SPRINKLER PIPING, PLUMBING, AND
BUILDING STRUCTURE. REVIEW UNRESOLVED CONFLICTS WITH ARCHITECT PRIOR TO
PROCEEDING WITH WORK.
12. ACCESS PANELS SHALL BE INSTALLED IN NON-ACCESSIBLE CEILINGS AT ANY LOCATION
REQUIRING FUTURE ACCESS (I.E.: JUNCTION BOXES, PIPING VALVES, VALVE CONTROLS, ETC.), WHETHER OR NOT INDICATED ON THE DRAWINGS. VERIFY SIZE AND LOCATIONS WITH
ARCHITECT PRIOR TO INSTALLATION. LOCATION OF ANY ACCESS PANELS REQUIRED IN
GYPSUM BOARD CEILING SHALL BE COORDINATED WITH DESIGN INTENT OF ARCHITECT PRIOR
TO INSTALLATION.
13. ACCESS PANELS TO BE INDEPENDENTLY MOUNTED, DO NOT SUPPORT ON CEILING GRID.
COORDINATE SIZE, QUANTITY AND LOCATIONS WITH ARCHITECTURAL AND MECHANICAL
DRAWINGS.
1 METAL MESH CEILING, ATTACH TO BOTTOM TRUSSES
2 WALL MOUNTED EXTERIOR LIGHTING FIXTURE; LITHONIA TWR LED WALL PACK; POWER TO
BE RUN FROM ADJACENT BUILDING - CONFIRM POWER CAPACITY AND AVAILABLE CIRCUITS
REFLECTED CEILING PLAN KEY NOTES:
(TYPICAL THIS SHEET ONLY)
3 P.E. WOOD TRUSS @ 24" O.C; TRUSS DESIGN BY TRUSS SUPPLIER
4 WOOD HEADER / LINTEL (3)2x12; PROVIDE METAL TRIM TO WATCH METAL SIDING
5 METAL SOFFIT PANEL; PROVIDE PERFORATED SOFFIT PANELS FOR VENTILATION AS
NECESSARY - MINIMUM NET FREE AREA OF 11 SF TOTAL
6 STEEL GUTTER AND DOWNSPOUTS; COLOR AS SELECTED BY OWNER
THIS DOCUMENT AND THE INFORMATION
CONTAINED THEREIN IS THE SOLE
POSSESSION OF STUDIO DETROIT AND
SHALL NOT BE ALTERED OR MODIFIED
WITHOUT THE EXPRESS WRITTEN
PERMISSION OF STUDIO DETROIT. ANY
MODIFICATION OR ALTERATION THEREOF
SHALL INDEMNIFY AND HOLD HARMLESS
STUDIO DETROIT OF ALL EXPENSES, CLAIMS
AND/OR LIABILITY RESULTING FROM SUCH
MODIFICATIONS OR ALTERATIONS.
� 2026 STUDIO DETROIT LLC
DO NOT SCALE DRAWINGS
2040 PARK AVENUE, SUITE 200
DETROIT, MICHIGAN 48226
STUDIO-DETROIT.COM
ISSUED
DRAWN
CHECKED
SEAL
CLIENT
PROJECT
PROJECT MANAGER
PROJECT NO.
191 PINE TREE LANE
SANDUSKY, MI 48471
SANDUSKY
COMMUNITY SCHOOLS
STORAGE BUILDING
A1.1
SMB
PNP
FLOOR PLAN
06.25.26 BID / PERMIT
125 DAVIS STREET
SANDUSKY, MI 48471
SANDUSKY
COMMUNITY SCHOOLS
PETER PENTESCU
PETE@STUDIO-DETROIT.COM
586.747.9717
26031
N
1/8" = 1'-0"
FIRST FLOOR PLAN - NEW WORK
N
FIRST FLOOR REFLECTED CEILING PLAN
1 JENSEN BRIDGE AND SUPPLY CORRUGATED METAL WALL PANEL OR EQUAL, PROVIDE ALL
TRIMS FOR COMPLETE SYSTEM; COLOR AND PROFILE AS SELECTED BY OWNER
EXTERIOR ELEVATION KEY NOTES:
(TYPICAL THIS SHEET ONLY)
2 MANUAL ROLL UP DOOR w/ LOCKABLE HASP ON EXTERIOR; OVERHEAD DOOR 600 SERIES OR
EQUAL
3 PREFINISHED METAL FASCIA, COLOR AS SELCTED BY OWNER
4 STEEL GUTTER AND DOWNSPOUTS; COLOR AS SELECTED BY OWNER
5 JENSEN BRIDGE AND SUPPLY NEW STANDING SEAM / METAL PANEL ROOF w/ SNOW
GUARDS OR EQUAL; COLOR AND PROFILE AS SELECTED BY OWNER
6 LINE OF NEW CONCRETE FOUNDATION
7 CMU BASE COURSE; PROVIDE METAL FLASHING BASE TRIM AT BOTTOM OF METAL PANEL
8 GABLE VENT AND TRIM; MIN. NET FREE VENTILATING AREA 5.5 SF EACH LOCATION
9 NEW GFCI, WET PROTECTED EXTERIOR OUTLET MOUNTED AT 18" AFF; POWER TO BE RUN
FROM ADJACENT BUILDING - CONFIRM POWER CAPACITY AND AVAILABLE CIRCUITS
10 WALL MOUNTED EXTERIOR LIGHTING FIXTURE; LITHONIA TWR LED WALL PACK; POWER TO
BE RUN FROM ADJACENT BUILDING - CONFIRM POWER CAPACITY AND AVAILABLE CIRCUITS
FIRST FLOOR
100' - 0"
X'
SEE STRUCT
B.O. FOUNDATION
T.O. ROOF
117' - 7"
B.O. TRUSS
110' - 0"
A3.1
MP-1
4" 12"
4" 12"
CMU-1
FIRST FLOOR
100' - 0"
X'
SEE STRUCT
B.O. FOUNDATION
T.O. ROOF
117' - 7"
B.O. TRUSS
110' - 0"
A3.1
MP-1
4" 12"
4" 12"
CMU-1
FIRST FLOOR
100' - 0"
Y'2
A3.1
SEE STRUCT
B.O. FOUNDATION
T.O. ROOF
117' - 7"
B.O. TRUSS
110' - 0"
H
W
OD6
8' - 0"
8' - 0" H
W
OD5
8' - 0"
8' - 0" H
W
OD4
8' - 0"
8' - 0" H
W
OD3
8' - 0"
8' - 0" H
W
OD2
8' - 0"
8' - 0" H
W
OD1
8' - 0"
8' - 0"
MP-1
MP-2
TYP
TYP
CMU-1
FIRST FLOOR
100' - 0"
Y'
A3.1
SEE STRUCT
B.O. FOUNDATION
T.O. ROOF
117' - 7"
B.O. TRUSS
110' - 0"
H
W
OD7
8' - 0"
8' - 0" H
W
OD8
8' - 0"
8' - 0" H
W
OD9
8' - 0"
8' - 0" H
W
OD10
8' - 0"
8' - 0" H
W
OD11
8' - 0"
8' - 0" H
W
OD12
8' - 0"
8' - 0"
MP-1
MP-2
TYP
TYP
CMU-1
THIS DOCUMENT AND THE INFORMATION
CONTAINED THEREIN IS THE SOLE
POSSESSION OF STUDIO DETROIT AND
SHALL NOT BE ALTERED OR MODIFIED
WITHOUT THE EXPRESS WRITTEN
PERMISSION OF STUDIO DETROIT. ANY
MODIFICATION OR ALTERATION THEREOF
SHALL INDEMNIFY AND HOLD HARMLESS
STUDIO DETROIT OF ALL EXPENSES, CLAIMS
AND/OR LIABILITY RESULTING FROM SUCH
MODIFICATIONS OR ALTERATIONS.
� 2026 STUDIO DETROIT LLC
DO NOT SCALE DRAWINGS
2040 PARK AVENUE, SUITE 200
DETROIT, MICHIGAN 48226
STUDIO-DETROIT.COM
ISSUED
DRAWN
CHECKED
SEAL
CLIENT
PROJECT
PROJECT MANAGER
PROJECT NO.
191 PINE TREE LANE
SANDUSKY, MI 48471
SANDUSKY
COMMUNITY SCHOOLS
STORAGE BUILDING
A2.1
SMB
PNP
EXTERIOR ELEVATIONS
06.25.26 BID / PERMIT
125 DAVIS STREET
SANDUSKY, MI 48471
SANDUSKY
COMMUNITY SCHOOLS
PETER PENTESCU
PETE@STUDIO-DETROIT.COM
586.747.9717
26031
SCALE: 3/16" = 1'-0"
EAST ELEVATION
SCALE: 3/16" = 1'-0"
WEST ELEVATION
SCALE: 3/16" = 1'-0"
NORTH ELEVATION
SCALE: 3/16" = 1'-0"
SOUTH ELEVATION
1 CONTINUOUS WALL FOOTING w/ 2 - #5 REINFORCING BARS; CONT. TOP AND BOTTOM
BUILDING SECTION KEY NOTES:
(TYPICAL THIS SHEET ONLY)
2 MIN. 4" COMPACTED SUBGRADE BASE
3 PAVING / GRADE; SLOPE AWAY FROM BUILDING MIN. 1/8"/ FT.
4 4" CONCRETE SLAB REINFORCED w/ 6x6 - W1.4xW1.4 W.W.F. PLACED IN UPPER THIRD OF
SLAB TYPICAL
6 1/2" PREFORMED EXPANSION JOINT
7 6" CMU BASE COURSE GROUTED SOLID
9 EXTERIOR WALL CONSTRUCTION:
10 P.E. WOOD TRUSS @ 24" O.C; TRUSS DESIGN BY TRUSS SUPPLIER
11 METAL MESH CEILING, ATTACH TO BOTTOM TRUSSES
12 STANDING SEAM / METAL PANEL ROOF ON ICE AND WATER SHIELD ON 3/4" PLYWOOD
SUBSTRATE ROOF SYSTEM; COLOR AS SELECTED BY OWNER
13 METAL SOFFIT PANEL; PROVIDE PERFORATED SOFFIT PANELS FOR VENTILATION AS
NECESSARY - MINIMUM NET FREE AREA OF 11 SF TOTAL
14 STEEL GUTTER AND DOWNSPOUTS; COLOR AS SELECTED BY OWNER
8 2x6 MRT TREATED SILL PLATE; PROVIDE 1/2" ANCHOR BOLT CONNECTION @ 32" O.C., TYP
CORRUGATED METAL PANEL
AIR / MOISTURE BARRIER
5/8" THK EXT. GRADE SHEATHING
2x6 WD STUDS @ 16" O.C.
5/8" THK PLYWOOD SHEATHING
15 WOOD HEADER / LINTEL (3)2x12; PROVIDE METAL TRIM TO WATCH METAL SIDING
16 MANUAL ROLL UP DOOR w/ LOCKABLE HASP ON EXTERIOR; OVERHEAD DOOR 600 SERIES OR
EQUAL
17 INTERIOR WALL CONSTRUCTION:
2x6 WD STUDS @ 16" O.C.
5/8" THK. PLYWOOD SHEATHING (2-SIDED AT BACK WALL
OF UNITS)
18 THICKENED SLAB w/ 2 - #5 REINFORCING BARS' CONT. BOTTOM
5 CONTINUOUS 6 MIL VAPOR BARRIER
FIRST FLOOR
100' - 0"
X'
SEE STRUCT
B.O. FOUNDATION
T.O. ROOF
117' - 7"
B.O. TRUSS
110' - 0"
A3.1
4" 12"
4" 12"
TYP
FIRST FLOOR
100' - 0"
Y'
SEE STRUCT
B.O. FOUNDATION
T.O. ROOF
117' - 7"
B.O. TRUSS
110' - 0"
A3.1
TYP
TYP
TYP
FIRST FLOOR
100' - 0"
SEE STRUCT
B.O. FOUNDATION
T.O. ROOF
117' - 7"
B.O. TRUSS
110' - 0"
V A
R
IE
S
'-0
'-4
6 7
FIRST FLOOR
100' - 0"
X'
SEE STRUCT
B.O. FOUNDATION
B.O. TRUSS
110' - 0"
'-0 "9
'-4
6 3/4" 1'-0"
4"
12"
6 7
THIS DOCUMENT AND THE INFORMATION
CONTAINED THEREIN IS THE SOLE
POSSESSION OF STUDIO DETROIT AND
SHALL NOT BE ALTERED OR MODIFIED
WITHOUT THE EXPRESS WRITTEN
PERMISSION OF STUDIO DETROIT. ANY
MODIFICATION OR ALTERATION THEREOF
SHALL INDEMNIFY AND HOLD HARMLESS
STUDIO DETROIT OF ALL EXPENSES, CLAIMS
AND/OR LIABILITY RESULTING FROM SUCH
MODIFICATIONS OR ALTERATIONS.
� 2026 STUDIO DETROIT LLC
DO NOT SCALE DRAWINGS
2040 PARK AVENUE, SUITE 200
DETROIT, MICHIGAN 48226
STUDIO-DETROIT.COM
ISSUED
DRAWN
CHECKED
SEAL
CLIENT
PROJECT
PROJECT MANAGER
PROJECT NO.
191 PINE TREE LANE
SANDUSKY, MI 48471
SANDUSKY
COMMUNITY SCHOOLS
STORAGE BUILDING
A3.1
SMB
PNP
BUILDING SECTIONS
06.25.26 BID / PERMIT
125 DAVIS STREET
SANDUSKY, MI 48471
SANDUSKY
COMMUNITY SCHOOLS
PETER PENTESCU
PETE@STUDIO-DETROIT.COM
586.747.9717
26031
A1.0 3/16" = 1'-0"
2 BUILDING SECTION
A1.0 3/16" = 1'-0"
1 BUILDING SECTION
A3.1 3/4" = 1'-0"
3 WALL SECTION
A3.1 3/4" = 1'-0"
4 WALL SECTION
FINISH SCHEDULE GENERAL NOTES
1. REFER TO MATERIAL / FINISH SCHEDULE FOR SPECIFIC FINISH TYPES.
2. AT DISCREPANCIES BETWEEN THE ROOM FINISH SCHEDULE AND DRAWINGS, THE ARCHITECT WILL DETERMINE THE FINISH.
3. ON ALL WALLS WHICH ARE COVERED WITH MILLWORK, ALL MASONRY JOINTS AS OCCUR SHALL BE TOOLED AND A FINISH IS NOT REQUIRED TO BE APPLIED TO THE WALL BEHIND EXCEPT FOR
LOCATIONS WHICH MAY BE EXPOSED.
4. FOR CEILING OR WALL MATERIAL WHEN MORE THAN ONE CEILING OR WALL MATERIAL OCCURS THE CEILING OR WALL FINISH IS INDICATED THUS: "/".
5. REFER TO FLOOR & CEILING PLANS AND INTERIOR ELEVATIONS FOR SPECIFIC FLOOR / WALL / CEILING FINISH LOCATIONS WHERE MULTIPLE FINISHES ARE INDICATED IN THE ROOM FINISH SCHEDULE.
FINISHES LISTED IN THE SCHEDULE ARE GENERAL, REFER TO THE DRAWINGS FOR ISOLATED AREAS OF OTHER ACCENT FINISHES.
6. PAINTING OF EXPOSED INTERIOR CONSTRUCTION SHALL INCLUDE:
A. STEEL GIRTS SUPPORTING EXTERIOR PREFINISHED METAL WALL PANELS
B. STEEL COLUMNS
C. ROOF CONSTRUCTION, INCLUDING BEAMS, TRUSSES, PURLINS, MISCELLANEOUS FRAMING, AND DECK
D. FLOOR CONSTRUCTION, INCLUDING BEAMS, TRUSSES, MISCELLANEOUS FRAMING, AND DECK
E. MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL, AND OTHER UTILITIES
F. STEEL LINTELS
G. STEEL CHANNELS / BENT PLATES AND FRAMING AT DOORS
7. PATCH ALL HOLES, ETC. LEFT BY ALL TRADES (INCLUDING ELECTRICAL AND MECHANICAL) PRIOR TO PAINTING. PAINT WALL(S) OR CEILING(S) NOT SCHEDULED TO BE PAINTED, WHICH HAVE HAD
PATCHING, FROM INSIDE CORNER TO INSIDE CORNER ACROSS ENTIRE SURFACE.
8. PROTECT ROOM FINISHES DURING INSTALLATION OF NEW WORK.
MOTOR OPERATORTRACKDOOR TYPE GLAZING CONTROLSJAMBSIZE W X H X THK. SAFETY REMARKS
OVERHEAD DOOR SCHEDULE
T R
O L
L E
Y M
O U
N T
S
ID
E M
O U
N T
F U
L L
V E
R T
IC
A
L
H I-
L
IF
T C
L E
A R
A N
C E
S T
A N
D A
R D
L
IF
T
L O
W H
E A
D R
O O
M
G L
A Z
E D
A L
U M
IN
U
M
IN
S
U L
A T
E D
S T
L
S E
C T
IN
S
U L
. G L
A S
S
C L
E A
R A
C R
Y L
IC
R A
D
IO
C O
N T
R O
L
C L
O S
E T
IM
E
R
L O
O P
D E
T E
C T
O R
F
IX
E D
C O
N T
R O
L
P H
O T
O E
Y E
S A
F E
T Y
E D
G E
S T
E E
L J
A M
B
-0
X
'-0
X
C E
N T
E R
J A
C K
S H
A F
T
E X
T E
R
IO
R P
R O
X
IM
IT
Y
D E
T E
C T
O R
S E
C U
R
IT
Y S
H U
T T
E R
M A
S O
N R
Y
W A
T E
R P
R O
O F
R O
L L
IN
G
S T
L . D
O O
R
H O
O D
G
U
ID
E S
D O
O R
E L
E V
A T
IO
N
VERIFY SIZE PRIOR TO
ORDERING
OD7
B R
A K
E S
Y S
T E
M
S .S
H
A R
D W
A R
E
C O
D E
A C
T
IV
A T
IO
N
OD10
OD11
OD6
C H
A
IN
D R
IV
E
N
N O
N E
G Y
P . B
D
W D
S
T U
D
OD8
OD9
F R
A M
E E
L E
V A
T
IO
N
IN
T
E R
IO
R
P R
O X
IM
IT
Y D
E T
E C
T O
R
OD2
OD1
OD3
OD5
OD4
OD12
RD
M O
T O
R H
O R
S E
P O
W E
R
V O
L T
A G
E
DOOR FINISH
F A
C T
O R
Y P
R
IM
E , F
A C
T O
R Y
P A
IN
T
E D
F A
C T
O R
Y P
R
IM
E D
, F
IE
L D
P A
IN
T
E D
WH
C L
E A
R A
N O
D
IZ
E D
B L
A C
K A
N O
D
IZ
E D
ROOM NAME
STORAGE 1
NUMBER
N O
N E
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
STORAGE 2
STORAGE 3
STORAGE 4
STORAGE 5
STORAGE 6
STORAGE 7
STORAGE 8
STORAGE 9
STORAGE 10
STORAGE 11
STORAGE 12
MANUAL PUSH UP OPERATION w/ LOCK
- -WH MANUAL PUSH UP OPERATION w/ LOCK
- -WH MANUAL PUSH UP OPERATION w/ LOCK
- -WH MANUAL PUSH UP OPERATION w/ LOCK
- -WH MANUAL PUSH UP OPERATION w/ LOCK
- -WH MANUAL PUSH UP OPERATION w/ LOCK
- -WH MANUAL PUSH UP OPERATION w/ LOCK
- -WH MANUAL PUSH UP OPERATION w/ LOCK
- -WH MANUAL PUSH UP OPERATION w/ LOCK
- -WH MANUAL PUSH UP OPERATION w/ LOCK
- -WH MANUAL PUSH UP OPERATION w/ LOCK
- -WH MANUAL PUSH UP OPERATION w/ LOCK
DOOR TYPE
"RD"
S E
E S
C H
E D
U L
E
SEE SCHEDULE
FRAME TYPE
WOOD JAMB (SEE PLAN)
HEADER PER PLANS
"3"
HEADPLATE
LIST OF MATERIALS
095000 - CEILINGS
MESH METAL MESH CEILING
MANUFACTURER: GKD METAL FABRICS
PRODUCT: DELTA 30 OR APPROVED EQUAL
LOCATION: -
GENERAL NOTES: ATTACH TO BOTTOM OF TRUSSES
033000 - HIGH PERFORMANCE COATINGS
CONC CONCRETE
PRODUCT: EXISTING TO REMAIN
LOCATION: MAIN FLOOR AREAS
GENERAL NOTES: -
042000 - UNIT MASONRY
MP-1 CORRUGATED METAL PANEL
PRODUCT: JENSEN BUILDING SUPPLY
COLOR: AS SELECTED BY OWNER
LOCATION: EXTERIOR FACADE
GENERAL NOTES: -
MP-2 STANDING SEAM METAL ROOF
PRODUCT: JENSEN BUILDING SUPPLY
COLOR: AS SELECTED BY OWNER
LOCATION: ROOF
GENERAL NOTES: PROVIDE SNOW GUARDS
077000 - METAL COPING / ACCENT
MET-1 FASCIA / GUTTERS
PRODUCT: JENSEN BUILDING SUPPLY
COLOR: AS SELECTED BY OWNER
LOCATION: -
GENERAL NOTES: PROVIDE ALL TRIMS FOR COMPLETE SYSTEM
07…
This is the start of the file's text. The full file is on GovTribe.