1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL AUTHORITIES, CODES, RULES AND REGULATIONS.
2. THESE DOCUMENTS SHOW THE MINIMUM CONSTRUCTION REQUIREMENTS AND THE MINIMUM QUALITY OF WORK EXPECTED. MORE STRINGENT REQUIREMENTS STIPULATED WITHIN RELEVANT MANUFACTURER’S INSTALLATION
INSTRUCTIONS WILL SUPERSEDE.
3. ANY UNFORESEEN OR UNCLEAR CONDITIONS SHALL BE REPORTED TO THE ARCHITECT AND VA CONTRACTING
OFFICER'S REPRESENTATIVE PRIOR TO PROCEEDING WITH WORK.
4. ANY CONFLICTS WITHIN THE DRAWINGS, BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, OR BETWEEN THE DRAWINGS AND THE ACTUAL CONDITIONS AT THE SITE, ARE TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT AND VA CONTRACTING OFFICER'S REPRESENTATIVE. THE CONTRACTOR SHALL NOT PROCEED WITH WORK
UNTIL WRITTEN CLARIFICATION FROM THE ARCHITECT IS RECEIVED.
5. UNLESS OTHERWISE NOTED, ALL MATERIALS AND EQUIPMENT ARE TO BE INSTALLED PER THE APPLICABLE
PROVISIONS OF THESE DOCUMENTS AND THE MANUFACTURER’S INSTRUCTIONS.
6. ALL MATERIALS USED ARE REQUIRED TO BE NEW UNLESS OTHERWISE NOTED AND/OR OF A QUALITY TO MEET OR EXCEED ALL APPLICABLE INDUSTRY STANDARDS. WHERE SPECIFIED PRODUCTS OR MANUFACTURERS ARE NOT NOTED, THE CONTRACTOR IS REQUIRED TO NOTIFY THE ARCHITECT TO OBTAIN A MINIMUM STANDARD OF QUALITY.
7. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL MEANS, METHODS AND TECHNIQUES FOR CONSTRUCTION.
8. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR JOB-SITE SAFETY INCLUDING BUT NOT LIMITED TO THE ADHERENCE
TO OSHA REGULATIONS.
9. ALL ELECTRICAL AND MECHANICAL WORK SHALL BE PERFORMED BY PERSONNEL LICENSED IN THE STATE WHERE
THIS PROJECT IS LOCATED.
10. REMOVE ALL DEBRIS PROPERLY FROM THE SITE. LOAD DEBRIS DIRECTLY ONTO TRUCKS OR INTO DUMPSTERS FOR
REMOVAL. DISPOSE OF DEBRIS LEGALLY. DO NOT BURN DEBRIS ON THE SITE. DO NOT ALLOW DEBRIS TO ENTER SEWERS. DO NOT ALLOW PILED DEBRIS TO ENDANGER STRUCTURES, BLOCK EXISTS OR ROADWAYS. COMBUSTIBLE WASTE WHICH COULD CREATE A FIRE HAZARD SHALL NOT BE PERMITTED TO ACCUMULATE IN OR AROUND THE
CONSTRUCTION SITE.
11. COORDINATE ALL WORK WITH ALL OTHER DISCIPLINES, INCLUDING, BUT NOT LIMITED TO MECHANICAL, ELECTRICAL, PLUMBING & SITE DRAWINGS. EXACT SIZE AND LOCATION OF ALL ROOF AND FLOOR OPENINGS SHOWN ON ARCHITECTURAL DRAWINGS SHALL BE VERIFIED WITH THE ASSOCIATED SUB-CONTRACTORS PRIOR TO
CONSTRUCTION.
12. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL GOVERN. ALL PLAN DIMENSIONS ARE TAKEN TO FINISH FACE OF
CONSTRUCTION.
13. LAYOUT AND VERIFY ALL PARTITION LOCATIONS PRIOR TO CONSTRUCTION FOR CLEARANCES AND DIMENSIONS.
NOTIFY ARCHITECT OF ANY DISCREPANCIES.
14. WITHIN ALL METAL STUD PARTITIONS, THE GENERAL CONTRACTOR IS TO PROVIDE BLOCKING FOR ALL WALL MOUNTED EQUIPMENT AND ACCESSORIES INCLUDING BUT NOT LIMITED TO: MECHANICAL, ELECTRICAL AND PLUMBING DEVICES, FURNITURE, CASEWORK, MILLWORK AND ALL OTHER WALL MOUNTED ACCESSORIES AND ITEMS. THE LOCATIONS, MOUNTING HEIGHTS AND BLOCKING REQUIREMENTS SHOWN HEREON ARE GIVEN FOR INFORMATIONAL PURPOSES ONLY AND IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY THIS INFORMATION WITH THE ASSOCIATED SUB-CONTRACTORS, MANUFACTURERS, OR EQUIPMENT SUPPLIERS. SEE TYPICAL BLOCKING DETAILS IN METAL STUD WALLS INCLUDED IN THESE DOCUMENTS FOR BLOCKING AND ANCHORING REQUIREMENTS.
15. ALL CONCEALED WOOD SHALL BE FIRE RETARDANT TREATED.
16. THE GENERAL CONTRACTOR SHALL COORDINATE WITH ALL OTHER DISCIPLINES INCLUDING BUT NOT LIMITED TO
MECHANICAL, ELECTRICAL AND PLUMBING, TO DETERMINE THE SIZE AND LOCATION OF ALL PENETRATIONS IN NEW CONSTRUCTION. COORDINATE AND PROVIDE ALL OPENINGS. SEAL CONSTRUCTION TIGHT TO ALL PENETRATIONS AND
CAULK.
17. ALL PENETRATIONS THROUGH FIRE RATED CONSTRUCTION MUST BE FIRE SAFED IN ACCORDANCE WITH THE
SPECIFICATIONS.
18. PROVIDE CONTROL JOINTS IN GYPSUM WALLBOARD INTERIOR PARTITIONS AT 30 FEET ON CENTER MAXIMUM. WHERE POSSIBLE, LOCATE AT CORNERS ABOVE OPENINGS. VERIFY LOCATIONS WITH ARCHITECT. SEE THE ASSOCIATED
TYPICAL DETAILS INCLUDED IN THESE DOCUMENTS.
19. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL EQUIPMENT INSTALLATION AND VERIFYING ALL REQUIRED ROUGH OPENINGS, AND ROUGH-IN DIMENSIONS WITH THE EQUIPMENT MANUFACTURER, OWNER AND
ARCHITECT PRIOR TO CONSTRUCTION.
GENERAL PROJECT NOTES FOR NEW WORK:
1. SEE GENERAL PROJECT NOTES FOR NEW WORK FOR ADDITIONAL REQUIREMENTS FOR WORK WITHIN THE EXISTING FACILITY.
2. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND FIELD CONDITIONS PRIOR TO DEMOLITION AND CONSTRUCTION. IF
PROVIDED, THE GENERAL CONTRACTOR SHALL CAREFULLY EXAMINE EXISTING BUILDING DOCUMENTS. THE CONTRACTOR SHALL BRING ANY
DISCREPANCIES TO THE IMMEDIATE ATTENTION OF THE ARCHITECT.
3. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF EXISTING ITEMS TO REMAIN DURING DEMOLITION AND CONSTRUCTION.
4. MAINTAIN EXIT EGRESS PATHS TO EXISTING EXIT DOORS DURING CONSTRUCTION.
5. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL CONSTRUCTION ROUTES BEYOND THE AREAS OF WORK AND THE
ROUTES MUST BE RETURNED TO THEIR ORIGINAL CONDITION AT THE END OF THE PROJECT.
6. MAINTAIN THE BUILDING IN A WEATHER TIGHT CONDITION AT ALL TIMES.
7. ALL DEMOLITION AND CONSTRUCTION ACTIVITIES SHALL BE COORDINATED WITH THE OWNER TO MINIMIZE DISRUPTIONS OF NORMAL FUNCTIONS OF
THE OWNER'S OCCUPIED AREAS.
8. IF CONSTRUCTION NOISE IS ANTICIPATED, SUBMIT A WRITTEN REQUEST TO THE OWNER FOR THE SCHEDULED TIME OF THE CONSTRUCTION
ACTIVITIES. NO WORK SHALL BE DONE WITHOUT THE WRITTEN APPROVAL OF THE OWNER. THE OWNER RESERVES THE RIGHT TO DISCONTINUE NOISY CONSTRUCTION AT ANY TIME. NO RADIOS SHALL BE PERMITTED AT ANY TIME IN WORK AREAS ADJACENT TO OCCUPIED SPACES.
9. ALL EXISTING SERVICES AND UTILITIES SHALL BE MAINTAINED TO ADJACENT DEPARTMENTS OR AREAS THAT ARE IN OPERATION AND SERVED BY THEM. COORDINATE ALL DISRUPTIONS OR DISCONTINUATIONS OF UTILITIES AND SERVICES WITH OWNER. NO SHUT DOWN OF EXISTING SERVICES IS ALLOWED TO OCCUR UNTIL RECEIVING THE OWNER'S WRITTEN APPROVAL OF THE SHUT DOWN SCHEDULE. PROVIDE TEMPORARY SERVICES
AND/OR UTILITIES DURING INTERRUPTIONS AS REQUIRED AND APPROVED BY THE OWNER.
10. THE GENERAL CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PREVENT DAMAGE TO OWNER'S OCCUPIED AREAS ADJACENT TO NEW CONSTRUCTION OR OCCUPIED AREAS WHERE VARIOUS SYSTEM CONNECTIONS OR EXTENSIONS ARE REQUIRED. IN THESE AREAS, THE GENERAL CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY LACK OF SUFFICIENT PROTECTION FROM THE WEATHER AND FROM THE RESULTS OF ALL
CONSTRUCTION ACTIVITY INCLUDING BUT NOT LIMITED TO DUST AND WATER.
11. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN APPROVAL FROM THE OWNER BEFORE USING OPEN FLAMES, WELDING RODS AND TORCHES.
THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL MEANS AND METHODS TO PROHIBIT THE MIGRATION OF SMOKE AND OTHER PRODUCTS OF COMBUSTION INTO OCCUPIED AREAS OF THE EXISTING BUILDING AND FOR OBTAINING ALL REQUIRED PERMITS RELATED TO HOT WORK.
12. PROVIDE FIRE PROTECTION IN ACCORDANCE WITH THE REQUIREMENTS OF THE GOVERNING AUTHORITY.
13. IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO PATCH ALL SPRAY-ON FIRE PROTECTION AT REMOVALS, AT ANY EXISTING LOCATIONS WHICH
ARE VOID OF PROTECTION WITHIN THE AREA OF WORK AND AT NEW CONSTRUCTION WHICH DISTURBS EXISTING FIRE PROTECTION. FIREPROOFING
MUST BE CONTINUOUS AND UNOBSTRUCTED.
14. DO NOT OVERLOAD THE EXISTING BUILDING STRUCTURE. MAINTAIN THE STRUCTURAL INTEGRITY OF ALL STRUCTURAL FRAMING MEMBERS AND
SYSTEMS AT ALL TIMES.
15. ALL DEMOLISHED MATERIAL, EXCEPT MATERIAL THAT IS LISTED OR MARKED BY THE ARCHITECT OR THE OWNER FOR RETENTION, SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND IT SHALL BE DISPOSED OF. NO DEBRIS RESULTING FROM WORK SHALL BE LEFT IN THE CONSTRUCTION
ROUTES BEYOND THE AREAS OF WORK.
16. REMOVAL OF A PARTICULAR ITEM IS TO INCLUDE ALL RELATED ITEMS, SUCH AS REMOVAL OF WALLS WOULD INCLUDE ASSOCIATED DOORS, HARDWARE, ELECTRICAL, PLUMBING, MECHANICAL, ETC. REFER TO DEMOLITION DRAWINGS FOR MORE INFORMATION. FOR ALL REMOVALS, THE GENERAL CONTRACTOR SHALL COORDINATE WITH ALL OTHER DISCIPLINES INCLUDING BUT NOT LIMITED TO MECHANICAL, ELECTRICAL AND
PLUMBING.
17. WHERE CEILINGS ARE SHOWN TO BE REMOVED, ALL UNUSED SUSPENDED EQUIPMENT, WIRES, ANGLES, ETC. SHALL BE REMOVED. SEE DEMOLITION DRAWINGS FOR ADDITIONAL INFORMATION. EXISTING LIGHTS MAY BE MAINTAINED AS TEMPORARY CONSTRUCTION LIGHTING.
18. THE CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT FOR ITEMS NOT DEMOLISHED OR REMOVED AS REQUIRED UNTIL PERMANENT SUPPORT
IS PROVIDED IN THE FINAL CONSTRUCTION.
19. ALL OPENINGS IN EXISTING WALLS, CEILINGS AND FLOORS, WHICH ARE THE RESULT OF REMOVALS AND OTHER NEW CONSTRUCTION ACTIVITY, SHALL BE PATCHED WITH NEW MATERIALS THAT MATCH THE EXISTING MATERIALS. IF THE PATCH IS TO BE MADE IN FIRE RATED CONSTRUCTION, THE PATCH MUST ACHIEVE THE REQUIRED FIRE RATING. THE PATCH SHALL BE FINISHED TO A LIKE NEW CONDITION TO MATCH THE EXISTING FINISH.
20. ALL EXISTING OPENINGS IN CEILINGS, FLOORS AND WALLS DISCOVERED IN THE EXISTING STRUCTURE SHALL BE PATCHED WITH NEW MATERIALS THAT MATCH THE EXISTING MATERIALS. IF THE PATCH IS TO BE MADE IN FIRE RATED CONSTRUCTION, THE PATCH MUST ACHIEVE THE REQUIRED FIRE RATING. THE PATCH SHALL BE FINISHED TO A LIKE NEW CONDITION TO MATCH THE EXISTING FINISH.
21. WHERE EXISTING SURFACES ARE TO BE REFINISHED OR ARE TO SERVE AS SUBSTRATE FOR THE ATTACHMENT OR APPLICATION OF NEW MATERIALS OR CONSTRUCTION, PREPARE OR ALTER THE EXISTING SURFACES AS NECESSARY TO PROPERLY ACCOMMODATE THE NEW MATERIALS.
22. FIELD VERIFY SIZES AND DIMENSIONS OF ALL EXISTING UTILITIES THAT IMPACT THE NEW WORK. DETERMINE THE SIZE AND LOCATION THE PENETRATIONS FROM THE EXISTING UTILITIES WITHIN THE NEW WORK. SEAL TIGHT TO ALL PENETRATIONS AND CAULK.
23. PENETRATIONS THROUGH EXISTING FIRE RATED CONSTRUCTION MUST BE PROPERLY CLOSED AND FIRE SAFED TO ACHIEVE THE PROPER FIRE
RATING BY THE END OF CONSTRUCTION OPERATIONS FOR EACH DAY.
24. NEW HOLES IN EXISTING ELEVATED FLOOR AND ROOF STRUCTURES FOR NEW WORK MUST BE COORDINATED WITH THE EXISTING STRUCTURE SO
THAT CRITICAL STRUCTURAL MEMBERS ARE NOT DAMAGED.
25. UNLESS OTHERWISE NOTED, THE GENERAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING SALVAGED STOCK BEFORE ORDERING
NEW MATERIAL.
GENERAL PROJECT NOTES FOR EXISTING FACILITIES:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Services
Engineering and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Chillicothe VA Chillicothe, OH
Renovate Student Housing Buildings 15 and 16 15
#538-19-204 W 5 Design LLC Architecture and Interior Design 515 Wyoming Ave.
Cincinnati Ohio 45215 513-376-0968
Ryan Jeter
C U s e rs
\n a te m \O n e
D ri v e
\D o c u m e n ts \F
F E
C h ill ic o th e
B n a te
.m o u ld s .r v t
/1
/2
:5
:5
A
M
GI000
COVER SHEET
01/05/2022 PH PH
RENOVATE STUDENT HOUSING
BUILDINGS 15 AND 16
SHEET NUMBER SHEET NAME
GENERAL
GI000 COVER SHEET
GI001 LIFE SAFETY PLAN
GI002 SITE ACCESS PLAN
GI003 ADA REQUIREMENTS
GI004 PARTITION TYPES/SCHEDULES
SITE DEVELOPMENT
CI1.10 CIVIL DETAILS
CD2.00 EXISTING SITE & DEMO PLAN
CS3.0 SITE LAYOUT PLAN
CG4.00 SITE GRADING PLAN
LS5.00 LANDSCAPE PLAN
STRUCTURAL
SB101 FOUNDATION PLAN, DETAILS, AND SECTIONS
ARCHITECTURAL
AD100 DEMOLITION PLANS BASEMENT
AD101 DEMOLITION PLANS 1ST FLOOR
AD102 DEMOLITION PLAN 2ND FLOOR
AE100 NEW WORK BASEMENT
AE101 NEW WORK PLAN 1ST FLOOR
AE102 NEW WORK PLANS 2ND FLOOR
AE131 ROOF PLANS
AC141 REFLECTED CEILING PLANS
AE201 EXTERIOR ELEVATIONS
AE401 INTERIOR ELEVATIONS NORTH
AE402 INTERIOR ELEVATIONS SOUTH
AE601 DOOR AND WINDOW DETAILS
AE900 ALTERNATE DEMOLITION PLANS 1ST FLOOR
AE901 ALTERNATE NEW WORK PLAN 1ST FLOOR
AE902 ALTERNATE 1ST FLOOR CEILING PLAN
AE903 ALTERNATE FURNITURE AND FINISH PLAN 1ST FLOOR
INTERIORS
IF100 FURNITURE AND FINISH PLAN BASEMENT
IF101 FURNITURE AND FINISH PLAN 1ST FLOOR
IF102 FURNITURE AND FINISH PLAN 2ND FLOOR
PLUMBING
PL001 PLUMBING LEGEND SHEET
PD101 PLUMBING BUILDING 15 BASEMENT DEMO PLAN
PD102 PLUMBING BUILDING 15 FIRST & SECOND FLOOR DEMO PLANS
PL101 PLUMBING BUILDING 15 BASEMENT NEW WORK PLAN
PL102 PLUMBING BUILDING 15 FIRST & SECOND FLOOR NEW WORK PLANS
PL501 PLUMBING SCHEDULES & DETAILS
PL601 PLUMBING BUILDING 15 SANITARY & VENT ISOMETRICS
PL602 PLUMBING BUILDING 15 DOMESTIC WATER ISOMETRICS
MECHANICAL
M001 MECHANICAL LEGEND, SYMBOLS, GENERAL NOTES
MD101 HVAC BUILDING 15 DEMOLITION
MD102 HVAC BUILDING 15 DEMOLITION
MH101 HVAC BUILDING 15 NEW WORK
MH102 HVAC BUILDING 15 NEW WORK
MH501 DETAILS
MH601 SCHEDULES
M901 ALTERNATE HVAC BUILDING 15 NEW WORK
MP501 STEAM DISTRIBUTION SCHEMATIC DEMOLITION AND NEW WORK
ELECTRICAL
E001 ELECTRICAL GENERAL INFORMATION
15ED100 PARTIAL ELECTRICAL DEMOLITION PLANS
15EL100 PARTIAL LIGHTING FLOOR PLANS
15EP100 PARTIAL POWER FLOOR PLANS
15EP600 PANEL SCHEDULES
15ES100 ELECTRICAL SITE PLAN
BUILDING 15 STREET VIEW OF FRONT ENTRANCES BUILDING 16 STREET VIEW OF FRONT ENTRANCES
DEPARTMENT OF VETERANS AFFAIRS
CHILLICOTHE, OHIO
D R A W I N G L I S T
Revisions: Date:
D W
Dryer Washer WasherDryer
DN
DN
UPUP
NFPA 2021 chapter 26 Lodging or Rooming Houses
26.1.1.1 The requirements of this chapter shall apply to buildings that provide sleeping accommodations for 16 or fewer persons on either transient or permanent basis, with or without meals, but without separate cooking facilities for individual occupants, except as provided in Chapter 24.
26.1.1.4 The requirements of this chapter shall apply to new buildings and to existing or modified buildings according to the provisions of 1.3.1 of this Code.
26.2 Means of Egress
26.2.1.1.1 Every sleeping room and living area shall have access to a primary means of escape complying with Chapter 24 and located to provide a safe path of travel to the outside.
26.2.1.2 Secondary Means of Escape: In addition to the primary route, each sleeping room and living area shall have second means of escape in accordance with 24.2.2 unless the sleeping room or living area has a door leading directly outside the building with access to the finished ground level or to a stairway that meets the requirements for exterior stairs in 26.2.1.1.2
24.2.2.3.3 It shall be an outside window or door operable from the inside without the use of tools, keys, or special effort and shall provide a clear opening of not less than 5.7 ft^2. The width shall be not less than 20”, and the height shall be not less than 24”. The bottom opening shall be not more than 44” above the floor. Such means of escape shall be acceptable where one of the following criteria is met:
1. The window shall be within 20’ of the finished ground level.
26.2.2 Stairways
26.2.2.1 Interior stairways, other than those in accordance with 26.2.2.2 or 26.2.2.3 shall comply with 7.2.2.5.3 and shall be enclosed by fire barriers having a minimum ½ hour fire resistance rating, with all openings protected with smoke actuated automatic closing or self-closing doors having a fire resistance comparable to that required for the enclosure.
26.2.2.2 Where an interior stair connects the street floor with the story next above or below only, but not with both, the interior stair shall be required to be enclosed only on the street floor.
26.2.3 Doors
26.2.3.1 Doors in a means of escape, other than bathroom doors in accordance with 26.2.3.2 and paths of travel in a means of escape shall be not less than 28” wide.
26.2.3.2 Bathroom doors shall be not less than 24” wide.
26.2.3.3 Every closet door latch shall be such that it can be readily opened from the inside in case of emergency.
26.2.3.4 Every bathroom door shall be designed to allow opening from the outside during an emergency when locked.
26.2.3.5 Door-locking arrangements shall comply with either 26.2.3.5.1 or 26.2.3.5.2
26.2.3.5.1 No door in any means of escape shall be locked against egress when the building is occupied.
26.2.3.5.2 Delayed egress locks complying with 7.2.1.6.1 shall be permitted, provided that not more than one such device is located in any one escape path
26.3 Protection
26.3.1 Protection of Vertical Openings
26.3.1.1 Vertical openings shall comply with 26.3.1.1.1, 26.3.1.1.2, or 26.3.1.1.3
26.1.1.1.1 Vertical openings shall be protected so that no primary escape route is exposed to an unprotected vertical opening.
26.1.1.1.1.1 Vertical openings shall be considered protected if the opening is cut off and enclosed in a manner that provides a smoke and fire resisting capability of not less than ½ hour.
26.1.1.1.1.2 Any door openings shall have smoke and fire resting capabilities to that of the enclosure and shall be automatic-closing on detection of smoker or shall be self-closing.
26.3.1.2 Exterior stars shall be protected against blockage caused by fire within the building.
26.3.3 Interior Finish
26.3.3.1 General: Interior finish shall be in accordance with section 10.2
26.3.4 Detection, Alarm and Communications Systems.
26.3.4.1 General
26.3.4.1.1 Lodging and rooming houses, other than those meeting 26.3.4.1.2 shall be provide with a fire alarm system in accordance with Section 9.6
26.3.4.1.2 A fire alarm system in accordance with section 9.6 shall not be required in existing lodging and rooming houses that have an existing smoke detection system meeting or exceeding the requirements of 26.3.4.5.1 where that detection system includes not less than one manual fire alarm box per floor arranged to initiate the smoke detection alarm.
26.3.4.2 Initiation: Initiation of the required fire alarm system shall be by manual means in accordance with 9.6.2, or by alarm initiation in accordance with 9.6.2.1 (3) in buildings protected throughout by an approved automatic sprinklered stem in accordance with 29.3.6.
26.3.4.3 Notification: Occupant notification shall be provide automatically in accordance with 9.6.3, as modified by 26.3.4.3.1 and 26.3.4.3.2
26.3.4.3.1 Visible signals for the hearing impaired shall not be required where the proprietor resides in the building and there are five or fewer rooms for rent.
26.3.4.3.2 Positive alarm sequence in accordance with 9.6.3.4 shall be permitted.
26.3.4.5 Smoke Alarm
26.3.4.5.1 Approved smoke alarms, other than existing smoke alarms meeting the requirements of 26.3.4.5.3 shall be installed in accordance with 9.6.2 in every sleeping room.
26.3.4.5.2 In other than existing buildings, the smoke alarms required by 26.3.4..5.1 shall be interconnected in accordance with 9.6.2.10.3
26.3.4.5.3 Existing battery powered smoke alarms, rather than house electric powered smoke alarms, shall be permitted where the facility has demonstrated the AHJ that the testing, maintenance, and battery replacement programs will ensure reliability of power to the smoke alarms.
26.3.4.6 Carbon Monoxide Alarms
26.3.4.6.1 Carbon Monoxide alarms or carbon monoxide detectors in accordance with Section 9.12 and 26.3.4.6 shall be provided in new lodging or rooming houses, where either of the following conditions occur.
1. Lodging or rooming houses with communicating attached garages, unless otherwise exempted by 26.3.4.6.3
2. Lodging or rooming houses containing fuel-burning appliances or fuel-burning fireplaces.
NOTE: FIRE PLACES ARE NOT USED AFTER THIS RENOVATION.
EXIT TRAVEL (DISTANCE)
SEMI-RECESSED FIRE EXTINGUISHER CABINET
(xx')
FEC
30 MIN FIRE RESISTANCE-RATED WALL - UL U407
1-HR SHAFT WALL - UL U415 SYSTEM A
BLDG. #
NORTH 0
SOUTH 1
LEVEL
BSMNT 0
LVL 1 1
LVL 2 2
ROOM #
ROOM NUMBERROOM NAME
15N SUN PORCH
15.01.06
15S SUN PORCH
15.11.06
195 SF
15N KITCHEN
15.01.05
190 SF
15S KITCHEN
15.11.05
151 SF
15S DINING
15.11.04
15S BED
15.11.03
15N BED
15.01.03
173 SF
15N DINING
15.01.04
238 SF
15N LIVING
15.01.02
217 SF
15S LIVING
15.11.02
15N CL
15.01.03A
15S CL
15.11.02A
15S TOILET
15.11.07
15N TOILET
15.01.07
108 SF
15N ENTRY
15.01.01
DN DN
78' - 10 7/8"
11' - 10 1/8" 11' - 8 3/4"
/4
/8
115 SF
15S ENTRY
15.11.01
(4
(5
15' - 0 5/8"
/8
( 5
(4
15N TOILET
15.02.03
132 SF
15S BED
15.12.04
15S TOILET
15.12.03
76 SF
15S BED
15.12.02
15S CL
15.12.02A
15S CL
15.12.01B
160 SF
15S BED
15.12.01
15S HALL
15.12.06
229 SF
15S BED
15.12.05
15S CL
15.12.04A
15S CL
15.12.05A 15S CL
15.12.01A
128 SF
15N BED
15.02.04
86 SF
15N BED
15.02.02
162 SF
15N BED
15.02.01
231 SF
15N BED
15.02.05
15N CL
15.02.04A
15N CL
15.02.05A
15N CL
15.02.01B
15N CL
15.02.02A
15N HALL
15.02.06
(56') (56')
702 SF
15S BASEMENT
15.10.01
710 SF
15N BASEMENT
15.00.01
183 SF
15S STORAGE
15.10.02
203 SF
15N STORAGE
15.00.02
15N CRAWL
15.00.03
15S CRAWL
15.10.03
15S MECH
15.10.02A
(50')
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Services
Engineering and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Chillicothe VA Chillicothe, OH
Renovate Student Housing Buildings 15 and 16 15
#538-19-204 W 5 Design LLC Architecture and Interior Design 515 Wyoming Ave.
Cincinnati Ohio 45215 513-376-0968
Ryan Jeter
C U s e rs
\n a te m \O n e
D ri v e
\D o c u m e n ts \F
F E
C h ill ic o th e
B n a te
.m o u ld s .r v t
/1
/2
:5
:5
A
M
GI001
LIFE SAFETY PLAN
01/05/2022 PH RR
3/16" = 1'-0"
15 1ST FLOOR NEW LIFE SAFETY PLAN
3/16" = 1'-0"
15 2ND FLOOR NEW LIFE SAFETY PLAN
3/16" = 1'-0"
15 BASEMENT NEW LIFE SAFETY PLAN
UP
UP
FF=686.41'
FF=686.39'
FF=686.44'
FF=677.94'
FF=677.96'
FF=686.42'
Bush es
Bushes
Bush es
Bushes
B ushes
Steps
Steps
San M H
R=68 1.34
I=671 .56 (W
I=671 .32
10" PVC
10" P
VC
10" PVC
10" PVC
Steam Manholes
Bldg. 16
20"X2 0"
Acces s
Panel
Steam Manhole
SteamManhole
C overed Porch
C overed Porch
686.41
680.69
684.36
679.90
679.35
679.49
685.55
680.92
680.27
679.17
680.48
686.40
678.36
678.63
678.94
678.56
678.59
678.98
679.25
679.50
679.58
679.66
679.27
679.25
679.64
679.85
684.69
685.03
685.20
685.44
685.66
685.95
686.24
686.55
686.75
686.85
679.04
678.95
677.96
677.94
680.58
682.44
683.27
683.25
683.51
683.04
682.30
680.49
684.43
680.38
684.60
684.60
684.86
685.04
685.25
685.84
686.29
685.77
685.81
685.98
686.06
685.90
685.78
685.62
685.83
685.14
684.25
683.58
682.84
683.10
684.12
684.65
684.44
683.01
683.27
684.33
684.60
684.75
684.73
684.65
684.48
684.39
684.73
684.26
683.74
683.50
682.90
682.19
682.34
677.41
677.43
677.55
677.55
678.47
678.47
678.59
678.58
687.02
686.81
686.63
686.57
686.32
686.20
686.05
685.71
685.49
685.29
685.23
685.12
685.00
684.81
680.50
680.62
680.62
680.57
680.61
680.48
681.68
681.69
681.63
682.14
682.13
682.06
677.61
677.52
684.94
684.95
684.90
684.90
679.46
679.51
679.47
679.46
679.53
679.42
679.32
679.54
684.30
684.20
683.35
677.30
677.42
678.52
678.44
680.50
680.52
682.10
684.83
686.16
686.13
683.16
684.26
682.47
683.23
683.53
685.00
685.01
682.39
680.89
685.77
685.97
686.59
686.57
686.57
686.55
686.55
686.57
685.43
685.42
685.40
685.42
685.38
685.40
685.47
685.49
684.81
684.80
679.65
680.05
680.24
680.21
680.06
680.12
680.50
680.50
680.27
680.17
680.26
680.49
680.48
678.76
679.18
679.60
679.65
679.25
679.13
678.56
678.59
679.13
679.17
679.22
679.21
679.48
679.69
680.16
680.56
680.74
681.00
680.40
679.89
679.27
679.25
679.90
679.97
680.16
680.07
680.47
681.05
681.40
680.78
681.00
681.28
681.69
681.51
681.31
681.32
681.68
681.61
681.93
682.85
683.89
684.41
685.13
685.57
685.86
686.26
686.39
686.33
686.36
686.57
686.06
685.97
685.90
685.94
686.20
680.78
681.03
681.02
681.06
681.06
681.06
681.04
680.77
680.71
680.44
680.18
680.14
679.69
680.24
680.60
680.73
680.73
680.73
680.77
680.96
681.00
681.40
681.91
681.91
682.47
682.91
683.12
683.92
684.67
685.27
685.70
686.51
686.58
686.58
686.62
686.60
686.52
686.54
686.49
686.28
686.31
686.32
678.94
679.17
679.73
679.68
680.10
680.16
680.31
680.81
682.11
682.83
683.29
683.50
684.01
684.68
684.82
684.79
684.81
680.22
680.75
682.06
682.82
683.23
683.95
684.59
684.98
684.94
680.19
680.33
680.37
680.42
680.37
680.50
680.98
682.34
683.80
684.36
684.93
684.91
684.89
684.85
684.94
685.12
685.00
684.84
684.95
684.93
680.56
680.95
682.31
683.81
684.39
684.55
684.81
684.90
684.97
685.23
680.56
680.70
680.89
680.99
681.08
681.02
681.04
681.03
680.77
681.26
682.70
683.74
684.04
684.53
685.04
685.66
685.90
685.81
685.91
686.05 680.74
681.28
682.79
683.74
684.10
684.94
686.02
686.04
680.74
680.88
681.68
681.18
681.27
681.73
681.72
681.70
681.94
682.06
686.41
686.39
686.42
686.44
685.13
680.52
677.41
677.40
677.41
680.46
677.55
677.63
677.58
681.50
678.47
678.49
678.48
682.02
678.58
678.58
678.59
681.91
683.00
683.16
683.12
683.09
683.14
678.72
685.83
686.21
681.86
683.20
684.29
679.53
680.21
680.97
681.05
681.02
680.69
684.45
684.72
684.98
685.17
685.42
685.65
685.98
686.28
686.47
686.60
685.98
680.16
680.16
680.58
686.99
682.58
680.92
681.22
683.74
682.84
683.00
686.95
687.15
687.04
687.04
687.05
686.98
687.10
687.10
687.08
687.08
687.07
687.02
687.08
686.03
686.01
686.00
685.99
686.02
686.03
686.09
686.06
686.04
686.02
686.05
680.19
680.50
680.61
680.62
680.61
680.61
680.58
686.97
680.88
681.53
681.73
681.71
682.15
682.12
682.13
681.86
686.94
686.58
686.62
686.60
686.58
686.58
686.57
686.56
686.58
685.43
685.42
685.39
685.43
685.38
685.42
685.49
685.48
680.12
681.67
685.22
685.65
683.49
681.34
681.85
685.99
685.97
681.71
686.98
682.56
681.91
686.83
686.94
680.18
680.12
680.17
680.45
680.54
680.52
680.50
680.23
680.19
680.15
681.51
680.89
680.88
681.01
684.44
684.33
684.14
684.03
683.19
682.11
684.88
685.19
685.85
685.95
686.21
686.17
685.95
685.79
685.77
686.10
686.18
685.97
685.65
685.61
686.06
686.04
685.69
685.61
685.11
684.33
681.88
683.16
683.69
684.33
684.30
684.91
684.89
684.55
684.38
684.43684.81
685.02
683.78
684.38685.98
684.42
684.52
684.97
684.94
684.49
684.66
684.80 684.41
685.02
682.41
684.27
679.52
686.69686.70
684.81684.83
679.53
681.44
685.87
685.90
680.53
680.52
680.46
680.45
685.87
685.86
686.89
686.77
681.50
681.50
682.02
682.11
686.86
686.83
679.65
678.45
681.36
681.23
681.09
680.81
680.69
678.83
678.93
679.05
679.26
679.63
679.95
680.10
680.21
679.97
680.12
680.37
680.66
680.88
680.75
680.70
680.74
680.78
680.89
680.75
681.57
684.87
683.93
679.11
679.11
678.99
678.73
678.74
679.01679.03
679.74
680.31
680.60
681.36
681.98
682.23
679.52
679.30
679.23
679.24
679.65
680.47
680.76
681.39
680.31
680.07
680.09
680.76
680.72
681.00
680.69
681.01
681.87
680.62
683.35
684.76
685.16
678.59
679.21
679.14
679.71
680.03
680.39
680.79
680.76
681.01
681.39
678.85
679.16
679.16
679.53
679.43
679.48
680.09
680.15
680.14
680.14
680.03
680.39
680.68
681.24
686.41
679.57
679.86
680.08
680.24
680.17
680.36
680.00
679.50
679.25
681.83
680.99
680.36
680.59
681.13
683.16
685.11
685.01
680.36
680.35
680.70
680.73
680.71
680.91
681.10
681.39
681.10
681.82
685.11
685.13
679.71
680.35
680.31
679.49
15"TREE
18"TREE
BC1
BC1
BC1
EWK1 BC1
EWK1 BC1
BC1
BC1
BC1
BC1
BC1
EWK1 BC1
EWK1 BC1
BC1
BC1
BC2
BC2
BC2
BC2
BC2
BC2
BC2
BC2
BC2
BC2
BLD15+7
BLD15
BLD15
BLD15
BLD15
BLD15
BLD15
BLD15-7 CLO
BLD16
BSH5
BSTP-7 FWL
BSTP-7
BSTP+7
BSTP-7 FWL
BSTP+7 FWL
BSTP-7
BSTP+7
FWL BSTP-7
BWK2
BWK2
BWK2
EWK10-7 BWK2
EWK12-7 BWK2
EWK10-7 BWK2
EWK7-7 BWK2
BWK2
BWK2
BWK2
BWK2 EWK6-7
EWK5-7 BWK2
EWK5+7 BWK2
EWK2-7 BWK2
EWK+7 BWL+7/6"
BWL/6"
BWL-7/6"
BWL+7/6"
BWL/6"
EWK-7 BWL-7/6"
EWK9+7 BWL+7/6"
BWL/6"
BWL-7/6"
BWL+7/6"
BWL/6"
EWK9-7 BWL-7/6"
BWL+7/10"
BWL-7/10"
BWL+7/6"
BWL/6"
BWL/6"
BWL-7/6"
CC+7
CC
CC
CC-7 CLO
CC+7
CC
CC
CC-7 CLO
CON
CON
CON
DRN/10"
DRN/10"
DRN/4"
DRN/6"
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
UGE1 EBX
TOE EC+7
TOE EC-7
EC+7
EC
EC
EC
EC
EC-7 CLO
EC+7
EC
EC
EC-7 CLO
EC+7
EC
EC
EC-7 CLO
TOE7 EC7+7
TOE8 EC7-7
UGE4 UGE+7 EMH
EWK
EWK
EWK
EWK
STEPS TOE-7 EWK-7
EWK+7 BWL+7/6"
EWK
EWK
EWK
EWK
EWK
EWK-7 BWL-7/6"
EWK1
EWK1
EWK1
EWK1
EWK1
EWK1
EWK1 BC1
EWK1 BC1
EWK1
EWK1
EWK1
EWK1
EWK1 UGT1
EWK1
EWK1
EWK1
EWK1
EWK1
EWK1
EWK1
EWK1 BC1
EWK1 BC1
EWK1
EWK1
EWK1
EWK1
EWK1
EWK1
EWK1
EWK10+7 EWK11+7
EWK10
EWK10
EWK10
EWK10
EWK10
EWK10
EWK10
EWK10
EWK10
EWK10
EWK10
EWK10
EWK10
EWK10
EWK10
EWK10
EWK10
EWK10
EWK10
EWK10-7 BWK2
TOE EWK10+7
EWK10
EWK10
EWK10
EWK10-7 BWK2
EWK10+7 EWK11+7
EWK11
EWK11
EWK11
EWK11
EWK11
EWK11
EWK11
EWK11
EWK11
EWK11
EWK11
EWK11
EWK11
EWK11
EWK11
EWK11
EWK11
EWK11
EWK11
EWK11
EWK11
STEPS+7 EWK12+7 FWL+7
EWK12
EWK12
EWK12
EWK12
EWK12
EWK12
EWK12
EWK12
EWK12
EWK12
EWK12
EWK12
EWK12
EWK12
EWK12
EWK12
EWK12
EWK12
EWK12-7 BWK2
EWK2
EWK2
EWK2
EWK2
EWK2
EWK2
EWK2
EWK2
EWK2
EWK2
EWK2
EWK2
EWK2
EWK2
EWK2
EWK2
EWK2-7 BWK2
EWK4+EWK+7
EWK4
EWK4
EWK4
EWK4
EWK4
EWK4
EWK4
EWK4-7
STEPS TOE+7 EWK5+7
EWK5
EWK5
EWK5
EWK5
EWK5
EWK5
EWK5
EWK5
EWK5
EWK5
EWK5-7 TOE7
EWK5+7 TOE7
EWK5
EWK5
EWK5-7 BWK2
EWK5+7 BWK2
EWK5
EWK5
EWK5-7
EWK6+7 EWK7+7
EWK6
EWK6
EWK6
EWK6
EWK6
EWK6
EWK6
EWK6
BWK2 EWK6-7
EWK6+7 EWK7+7
EWK7
EWK7
EWK7
EWK7
EWK7
EWK7
EWK7
EWK7
EWK7
EWK7
EWK7
EWK7
EWK7
EWK7
EWK7
EWK7
EWK7
EWK7
EWK7-7 BWK2
EWK8+7 EWK9+7
EWK8
EWK8
EWK8
EWK8
EWK8
EWK8
TOE EWK8-7
EWK8+7 EWK9+7
EWK9 STEPS TOE+7
EWK9+7 BWL+7/6"
EWK9
EWK9
EWK9
EWK9
EWK9
EWK9
EWK9-7 BWL-7/6"
FF
FF
FF
FF
UGW5- 7 FH
TSTP- 7 FWL+7
BSTP-7 FWL
FWL
FWL-7
TSTP+7 FWL+7
BSTP-7 FWL
FWL
FWL-7
TSTP- 7 FWL+7
BSTP+7 FWL
FWL
FWL-7
FWL+7 TSTP+7
FWL BSTP-7
FWL
FWL-7
STEPS+7 EWK12+7 FWL+7
FWL- 7 POR4
FWL+7
FWL
FWL
FWL-7
GND
GND
GND
GND
GND
GND
20"X20"
UGE1 LP
MH/STEAM
MH/STEAM
MH/STEAM
MH/STEAM
PAV
PAV
PAV
PAV
PAV
PAV
PAV
PAV
PAV
PAV
SPUR150/CN
SPUR151/CN
SPUR152/CN
SPUR153/CN
SPUR154/CN
SAN MH
TOE+7 POR1
STEPS TOE-7 EWK-7
STEPS TOE+7
TOE
TOE-7
TOE+7 RAIL+7
TOE
STEPS TOE- 7 RAIL-7
STEPS TOE+7 EWK5+7
TOE-7 POR2
TOE+7
STEPS TOE-7
EWK9 STEPS TOE+7
TOE-7
TOE+7
TOE
TOE
TOE
TOE+7
TOE-7
TOE+7
TOE
TOE
TOE
TOE-7
TOE+7
TOE
TOE
TOE EC+7
TOE-7
TOE+7
TOE EC-7
TOE
TOE
TOE EWK10+7
TOE EWK8-7
TOE
TOE
TOE
TOE-7
STEPS TOE1+7
TOE7+7
TOE7
TOE7
TOE7
EWK5-7 TOE7
EWK5+7 TOE7
TOE7
TOE7
TOE7TOE7 EC7+7
TOE7-7
TOE8+7
TOE8TOE8
TOE8
TOE8
TOE8
TOE8
TOE8
TOE8
TOE8 EC7-7
TOE8
TOE8-7
TOP+7
TOP-7
UGE4+7 TRANS/36"X40"
TRAV100/CNTRAV100/CN
TRAV101/CNTRAV101/CN
TRAV102/IPC
TRAV103/CN
TSTP+7
STEPS TSTP-7
TSTP+7
TSTP- 7 FWL+7
TSTP+7 FWL+7
TSTP-7
TSTP+7
STEPS TSTP-7
TSTP+7
TSTP- 7 STEPS
TSTP+7
TSTP- 7 FWL+7
FWL+7 TSTP+7
TSTP-7
TSTP+7
TSTP- 7 STEPS
UGE4 UGE+7 EMH
UGE-7
UGE3 UGE+7
UGE
UGE
UGE
UGE-7
UGE1
UGE1
UGE1
UGE1
UGE1
UGE1
UGE1
UGE1 LP
UGE1
UGE1
UGE1
UGE1
UGE1
UGE1
UGE1
UGE1
UGE1
UGE1 EBX
UGE1
UGE1
UGE1
UGE1-7
UGE3+7
UGE3
UGE3
UGE3
UGE3
UGE3UGE3
UGE3
UGE3
UGE3
UGE3 UGE+7
UGE3
UGE3
UGE4+7 TRANS/36"X40"
UGE4
UGE4
UGE4
UGE4 UGE+7 EMH
UGE4
UGE4
UGE4
UGT1
UGT1
UGT1
UGT1 LID/20"X20"
UGT1
EWK1 UGT1
UGT1
UGT1
UGT1
UGT1
UGT1
UGT1
UGT1
UGT1
UGT1-7
UGT2+7
UGT2
UGT2
UGT2-7
UGT4
UGW3+7 UGW+7 UGW2+7
UGW
UGW
UGW
UGW
UGW-7
UGW3+7 UGW+7 UGW2+7
UGW2
UGW2
UGW2
UGW2 UGW5+7
UGW2-7
UGW3+7 UGW+7 UGW2+7
UGW3 WV
UGW3
UGW3
UGW3
UGW3
UGW3 UGW4+7
UGW3-7
UGW3 UGW4+7
UGW4
UGW2 UGW5+7
UGW5- 7 FH
UGW3 WV
WV
18"TREE
954955
923924
100104
101105
319320
E
ELEC
MH
H Y D
PL
SMH
X
WV
WV
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Services
Engineering and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Chillicothe VA Chillicothe, OH
Renovate Student Housing Buildings 15 and 16 15
#538-19-204 W 5 Design LLC Architecture and Interior Design 515 Wyoming Ave.
Cincinnati Ohio 45215 513-376-0968
Ryan Jeter
C U s e rs
\n a te m \O n e
D ri v e
\D o c u m e n ts \F
F E
C h ill ic o th e
B n a te
.m o u ld s .r v t
/1
/2
:5
:5
A
M
GI002
SITE ACCESS PLAN
01/05/2022 PH BL
1" = 10'-0"
SITE ACCESS PLAN - EXISTING CONDITIONS
BLDG
BLDG
EXISTING DRIVE
& DELIVERY
THIS SIDE
EXISTING
GARAGE
EXISTING
STREET
KEEP
CLEAR
BLDG
BLDG
THE CONSTRUCTION FENCE
LIMITS SHOWN ARE
APPROXIMATE GENERAL LIMITS
OF THE MAIN CONSTRUCTION
ZONE. THE CONTRACTOR SHALL
PROVIDE CONSTRUCTION
FENCING PER THE
SPECIFICATION AROUND ALL
EXTERIOR WORK AND ADJUST
LIMITS OF THE FENCING TO
SAFEGUARD THE PUBLIC.
CONTRACTOR PARKING BETWEEN
GARAGES - MAINTAIN DRIVE
ACCESS AT ALL TIMES.
SEE ENLARGED
PLAN THIS SHEET
Revisions: Date:
THE CONTRACTOR SHALL
PROVIDE NECESSARY
CONSTRUCTION ZONE
WARNING AND DETOUR
SIGNAGE FOR ALL WORK
THAT IMPACTS
ROADWAYS AND
WALKS. COORDINATE
SIGNAGE AND DETOUR
PLANS WITH THE COR
IN ADVANCE OF THE
WORK.
MIN
1' - 3"
C L R
K N
E E
S P
A C
E
M
IN
M A
X T
O R
IM
R E
F L E
C T
E D
S U
R F
A C
E O
F M
IR
R
O R
M A
X T
O B
O
VERIFY SIZE WITH
PLANS AND ELEVATIONS
MIN
8" DEEP
T O
R
IM
M A
X
2'-1" MAX
1'-5" MIN
M
IN
M
IN
SIDE VIEW FRONT VIEW
CLEARANCE
6" MAX TOE
1'-5" MIN
LAVATORY
PLUMBING LINES
WITHIN HATCHED
AREA REQUIRED
TO BE INSULATED
LINES OF REQUIRED
CLEARANCE
FINISH FLOOR
4'-0" MIN CLR
M
IN
M
IN
CLEAR SPACE
ALLOWABLE FOR
ACCESSIBILITY
MIRROR
M
IN
LINES OF REQUIRED
CLEARANCE
M
IN
2'-6" MIN
M
IN
M
A X
SINK
CLEAR FLOOR
SPACE
M
IN
2'-6" MIN
5' - 0" 4
F
L O
O R
M O
U N
T
W
A L
L H
U N
G
1'-6" MAX
1'-4" MIN
M
IN
M
A X
WATER CLOSET
SINK
CLEAR FLOOR
SPACE
5' - 0"
F
L O
O R
M O
U N
T
W
A L
L H
U N
G
1'-6" MAX
1'-4" MIN
4'-0" MIN
M
IN
1'-7" MAX
WATER CLOSET
SINK
CLEAR FLOOR SPACE
CLEARANCE AT WATER CLOSET CLEARANCE AT WATER CLOSET
CLEARANCE AT SINK
4' - 6"
RELATIONSHIP OF FIXTURES AND CLEARANCES
2' - 2"
6' - 0"
UP-SWINGING
GRAB BAR
CLEAR FLOOR
SPACES
WATER CLOSET
SINK
M
IN
2'-6" MIN
GRAB BAR
G E N E R A L S H E E T N O T E S :
1. ACCESSIBILITY DETAILS SHOWN SHALL BE USED WHERE ACCESSIBLE WORK IS IDENTIFIED IN THESE
DOCUMENTS OR OTHERWISE REQUIRED. CONTRACTOR SHALL THOROUGHLY REVIEW THESE DOCUMENTS.
SHOULD ANY CONFLICTS IN THESE DOCUMENTS ARISE, THE CONTRACTOR SHALL NOTIFY OWNER'S REPRESENTATIVE IN WRITING PRIOR TO PURCHASE, INSTALLATION, AND CONSTRUCTION OF ANY ELEMENT
OF THE WORK.
2. APPLICABLE ACCESSIBILITY STANDARDS AND CODES ARE SHOWN IN THE CODE INFORMATION ON SHEET G001.
3. WHERE MORE THAN ONE CODE AND/ OR STANDARD IS INDICATED AS BEING APPLICABLE, THE MOST
STRINGENT CASE SHALL BE ADHERED TO.
4. STANDARDS AND CODES ON THIS SHEET ARE APPLICABLE TO ADA, ICC/ANSI A117.1 AND THE OHIO PLUMBING
CODE UNLESS OTHERWISE NOTED.
5. TOE CLEARANCE AT THE FRONT OF THE PARTITIONS IS NOT REQUIRED IN A COMPARTMENT GREATER THAN 5'-2" DEEP WITH A WALL-HUNG WATER CLOSET OR 5'-5" DEEP WITH A FLOOR-MOUNTED WATER CLOSET. TOE CLEARANCE AT THE SIDE IS NOT REQUIRED IN A COMPARTMENT GREATER THAN 5'-6" WIDE (ICC/ANSI A117.1).
TOE CLEARANCE IS EXCLUSIVE OF PARTITION SUPPORT MEMBERS. IF DEPTH OF STALL IS GREATER THAN 5'-0"
TOE CLEARANCE DOES NOT APPLY (ADA/ANSI A117.1 GOVERNS).
MAX
1' - 0" 3'-6" MIN
M
A X
T O
S E
A T
M
IN
T O
O U
T L E
T O
F D
IS
P
E N
S E
R
M
IN
T O
M A
X A
F F
M
A X
T O
B A
R
M
IN
9" MAX
7" MIN
GRAB BAR
1"
SANITARY NAPKIN
DISPOSAL AT WOMEN
OR UNISEX, SUGGESTED
LOCATION
GRAB BAR
M
A X
T O
B A
R
M
IN
1'-6" MAX
1'-4" MIN
SANITARY NAPKIN
DISPOSAL AT WOMEN OR
UNISEX, SUGGESTED
LOCATION
1 1/2"
3'-0" MIN
6" MAX
2'-0" MIN 1'-0" MIN.
M
A X
M
IN
M
IN
3'-5" MAX
3'-3" MIN
VERTICAL GRAB BAR
TOILET PAPER
DISPENSER
4'-6" MIN
M
A X
M
IN
M
IN
SIDE WALL REAR WALL
VERTICAL GRAB BAR
FLOOR CLEARANCE
5' - 0"
O P
E R
A T
IN
G
M E
C H
A N
IS
M
M A
X T
O
SOAP DISH
RECESS
SANITARY NAPKIN
DISPOSAL
(WOMEN'S ONLY)
6'
SHOWER CURTAIN ROD
TOWEL BAR
TOWEL PIN
SHOWER HEAD
U F
C G
U
ID
E L
IN
E
M A
X A
F F
A
B O
V E
S
IN
K T
O B
/O R
E F
L S
U R
F A
C E
MIRROR TOILET PAPER
DISPENSER
M
A X
M
IN
O P
E R
A T
IN
G
M E
C H
A N
IS
M
M A
X T
O
PAPER TOWEL
DISPENSOR
RECESS
O P
E R
A T
IN
G
M E
C H
A N
IS
M
M A
X T
O
O P
E R
A T
IN
G
M E
C H
A N
IS
M
GENERAL SYMBOLS
SCALE:?
DETAIL TITLE
BUILDING SECTION
WALL SECTION
EXTERIOR / INTERIOR
ELEVATION
INTERIOR MULTI-VIEW
ELEVATION
DETAIL SECTION
15A 106
C4
AE201
ELEVATION NUMBER
SHEET ON WHICH
ELEVATION IS DRAWN
ELEVATION NUMBER
SHEET ON WHICH
ELEVATION IS DRAWN
? DOOR NUMBER
KEYNOTE
WALL TYPE
ELEVATION INDICATION
NORTH ARROW
WINDOW NUMBER?
VIEW NAME
1/8"=1'-0"
15A300
SIM 3
15A300
SIM
15A300
SIM
15A300
SIM
BLDG. #
NORTH 0
SOUTH 1
LEVEL
BSMNT 0
LVL 1 1
LVL 2 2
ROOM #
ROOM NUMBER
W1
P1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Services
Engineering and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Chillicothe VA Chillicothe, OH
Renovate Student Housing Buildings 15 and 16 15
#538-19-204 W 5 Design LLC Architecture and Interior Design 515 Wyoming Ave.
Cincinnati Ohio 45215 513-376-0968
Ryan Jeter
C U s e rs
\n a te m \O n e
D ri v e
\D o c u m e n ts \F
F E
C h ill ic o th e
B n a te
.m o u ld s .r v t
/1
/2
:5
:0
A
M
GI003
ADA REQUIREMENTS
01/05/2022 PH RR/BL
1/2" = 1'-0"
TYP. ACCESSIBLE LAVATORY CLEARANCE
1/4" = 1'-0"
TYP. CLEAR FLOOR SPACES
1/2" = 1'-0"
TYP. ACCESSIBLE TOILET CLEARANCE
1/2" = 1'-0"
TYP. RESTROOM FIXTURES AND ACCESSORIES
STUD
SIZENUMBER STUD GAUGE /
MAX. HEIGHT
STUD
SPACING
GYPSUM
BOARD
WALL
THICK. INSULATION FIRE
RATING UL NUMBER
TOP OF STRUCTURAL SLAB
SCHEDULED FLOOR FINISH
CONTINUOUS SEALANT AT BOTH SIDES
OF RUNNER (TOP & BOTTOM)
SCHEDULED BASE
CONT. MTL "C" RUNNER AND
FASTENERS @ 24" O.C. MIN.
FULL HEIGHT SOUND ATTENUATION
BLANKET
METAL STUDS
(1) LAYER GYP. BD. ON EACH SIDE
EXISTING STRUCTURE ABOVE
CONTINUOUS DEEP LEG DEFLECTION
TRACK FOR 1/2" STRUCTURE
DEFLECTION
EXTENDS STUDS TO STRUCTURE ABOVE
SCHEDULED CEILING AS PER REFLECTED
CEILING PLAN ON EITHER SIDE OF
PARTITION
FULL HEIGHT PARTITION (STC 45)
STUD
SIZENUMBER STUD GAUGE /
MAX. HEIGHT
STUD
SPACING
GYPSUM
BOARD
WALL
THICK. INSULATION FIRE
RATING UL NUMBER
SCHEDULED CEILING
MTL. STUDS
SCHEDULED BASE
CONTINUOUS SEALANT AT RUNNER
SCHEDULED FLOOR FINISH
CONT. MTL "C" RUNNER AND
FASTENERS @ 24" O.C. MIN.
FACE OF EXISTING WALL OR COLUMN
EXISTING STRUCTURE ABOVE
EXTEND GWB AND STUDS 6" BEYOND
CEILING LEVEL
TOP OF STRUCTURAL FLOOR
(1) LAYER OF GYPSUM BD.
6"
FURRING PARTITION
- N/A- N/A1
SECTION AT FLR
PLAN
SECTION AT CLG
SECTION AT FLR
PLAN
SECTION AT CLG
3 5/8" 16" O.C.
5/8" GYP
4 7/8"5/8" TILE BACKER20 G / 16'-5"
U4191 HR1A 3 5/8" 16" O.C. 5/8" GYP TYP X 4 7/8"5/8" GYP TYP X 3" SOUND
ATTENUATION
BLANKET
20 G / 16'-5"
N/AN/A2 3 5/8" 16" O.C. -- 4 1/4"
5/8" GYP TYP X
--20 G / 16'-5"
STUD
SIZENUMBER STUD GAUGE /
MAX. HEIGHT
STUD
SPACING
GYPSUM
BOARD
WALL
THICK. INSULATION FIRE
RATING UL NUMBER
SCHEDULED CEILING
MTL. STUDS
SCHEDULED BASE
CONTINUOUS SEALANT AT RUNNER
SCHEDULED FLOOR FINISH
CONT. MTL "C" RUNNER AND
FASTENERS @ 24" O.C. MIN.
EXISTING STRUCTURE ABOVE
EXTEND GWB AND STUDS 6" BEYOND
CEILING LEVEL
TOP OF STRUCTURAL FLOOR
(1) LAYER OF GYPSUM BD.
6"
SHAFTWALL PARTITION
SECTION AT FLR
PLAN
SECTION AT CLG
N/AN/A3 3 5/8" 16" O.C. -- 4 1/4"
5/8" GYP TYP X
-20 G / 16'-5"
3 1/2" SOUND
ATTENUATION
BLANKET
N/AN/A2A 2 1/2" - -- 3 1/8"
5/8" GYP
--20 G / 12'-10"
STUD
SIZENUMBER STUD GAUGE /
MAX. HEIGHT
STUD
SPACING
GYPSUM
BOARD
WALL
THICK. INSULATION FIRE
RATING UL NUMBER
WINDOW INFILL
N/AN/A4 3 5/8" 16" O.C. -- 4 1/4"
5/8" GYP TYP X
-20 G / 16'-5"
REMOVE EXISTING SILL
REMOVE EXISTING WINDOW
TRIM AND FRAME
EXISTING WOOD STUDS
EXISTING BRICK VENEER
EXISTING SHEATHING
DEMOLISH EXISTING PLASTER
CERAMIC TILE
9 1/4"
REMOVE EXISTING WINDOW
TRIM AND FRAME
DEMOLISH EXISTING PLASTER
CERAMIC TILE
EXISTING WOOD STUDS
EXISTING BRICK VENEER
EXISTING SHEATHING
INSULATED 3 5/8" METAL STUD
CEMENT BOARD
1/2" GYPSUM SHEATHING
BRICK VENEER AT INFILL
TO MATCH EXISTING
BRICK TIE 16" O.C.
HORIZONTAL AND VERTICAL
CONTINUOUS SEALANT
INTERIOR STUD GAGE AND SPACING CHART*
STUD
WIDTH
DESIGN
THICKNESS
(GAGE)
STUD
SPACING
(INCHES)
PARTITION HEIGHT
DEFLECTION VALUE 5 psf
BRACING
SPACING WHERE
OCCURSL/120 L/240 L/360
1 5/8"
0.0179 " (25)
0.0312" (20)
0.0179 " (25)
0.0312" (20)
0.0179 " (25)
0.0312" (20)
0.0179 " (25)
0.0312" (20)
0.0179 " (25)
0.0312" (20)
2 1/2"
3 5/8"
4"
6"
16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
10'-7"
9'-9"
12'-1"
11'-0"
13'-3"
11'-10"
16'-5"
14'-10"
15'-4"
13'-9"
20'-8"
18'-6"
17'-2"
15'-1"
23'-1"
20'-9"
19'-9"
16'-9"
30'-10"
27'-2"
8'-4"
7'-11"
9'-8"
8'-9"
11'-3"
10'-7"
12'-10"
11'-7"
14'-4"
13'-5"
16'-5"
14'-9"
15'-4"
14'-2"
18'-4"
16'-5"
19'-9"
16'-9"
24'-6"
21'-7"
8'-5"
7'-8"
9'-10"
9'-3"
11'-2"
10'-0"
12'-4"
11'-7"
14'-3"
12'-9"
13'-4"
12'-4"
15'-11"
14'-3"
17'-11"
16'-9"
21'-4"
18'-10"
4'-0" OC
4'-0" OC
4'-0" OC
4'-0" OC
6'-0" OC
6'-0" OC
6'-0" OC
6'-0" OC
8'-0" OC
8'-0" OC
8'-0" OC
8'-0" OC
8'-0" OC
8'-0" OC
8'-0" OC
8'-0" OC
10'-0" OC
10'-0" OC
10'-0" OC
10'-0" OC
1. PROVIDE MINIMUM 0.0312" STUDS AT WALLS TO RECEIVE FINISH (TILE, STONE, WOOD, ETC.)
2. PROVIDE MINIMUM 0.0312" STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE
WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.
3. USE 5/8" FR GWB AT ALL FIRE-RATED PARTITIONS, ANCHOR W/ SCREWS AT 8" OC ON EDGES AT 12" OC IN FIELD PER UL DESIGN NUMBERS LISTED.
4. SEE ALL SPECIFICATIONS FOR GWB REQUIREMENTS AT TOILETS AND ALL WET AREAS.
5. APPLIES TO POWER AND COMMUNICATIONS, ETC.
A) BACK-TO-BACK PLACEMENT OF OUTLET BOXES NOT PERMITTED.
B) PLUG ALL UNUSED KNOCK-OUTS IN OUTLET BOXES WITH KNOCK-OUT CAPS
C) PROVIDE 'HILTI' FIRESTOP PUTTY PAD OR EQUAL TO OUTLET BOXES
D) DEPTH OF OUTLET BOX TO BE COMPATIBLE WITH STUD SIZES IN ORDER TO ACCOMMODATE BOX PAD
6. PROVIDE 2" X 6" WOOD BLOCKING AT WALL HUNG CASEWORK, SHELVES, COUNTERTOPS, HEAVY WALL SCONCES, AND MAJOR ARTWORK.
7. FOR LOCATIONS OF EXISTING AND NEW FIRE-RATED PARTITIONS,SEE LIFE SAFETY PLANS.
8. TYPE 1A - MATCH EXISTING WALL THICKNESS V.I.F.
9. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL WALL STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER REQUIREMENTS FOR MAXIMUM ALLOWED
HEIGHT AND DEFLECTION.
INTERIOR STUD CHART NOTES:
* REFERENCE STEEL STUD MANUFACTURER ASSOCIATION'S STANDARDS FOR SECTION PROPERTIES AND DESIGN OF STUD SIZE LISTED HERE
USE L/240 DEFLECTION CHART FOR ALL AREA UNLESS OTHERWISE NOTED.
G E N E R A L N O T E S :
1. BUILD PARTITIONS IN ACCORDANCE WITH PARTITION SCHEDULE AND DESIGN REFERENCED. REFERENCES ARE TO LATEST EDITION OF GYPSUM ASSOCIATION (GA) FIRE RESISTANCE DESIGN MANUAL, OR TO UNDERWRITERS LABORATORY (UL) FIRE RESISTANCE DIRECTORY.
2. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED OTHERWISE. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.
3. METAL STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A PARTITION BRACING ELEMENT.
4. EDGES OF GYPSUM WALL BOARD (GWB) LEFT EXPOSED TO VIEW, OR ABUTTING DISSIMILAR MATERIAL, IS TO BE FINISHED WITH "L" OR "J" BEAD
TRIM AND COMPOUND UNLESS NOTED OTHERWISE.
5. ALL FIRE RATED WALL AND FLOOR PENETRATION MUST COMPLY WITH ASTM-E814
6. ALL DOOR OPENINGS SHALL BE 4" FROM A PERPENDICULAR PARTITION TO OUTSIDE FACE OF FRAME, UNLESS NOTED OR DETAILED OTHERWISE.
7. ALL PARTITIONS, INCL. STUDS, BOARD, SOUND ATTENUATION BLANKETS, ETC. TO EXTEND FROM TOP OF FLOOR SLAB TO UNDERSIDE OF
CONCRETE SLAB ABOVE UNLESS OTHERWISE NOTED.
8. CONTRACTOR IS TO CLOSE OFF ANY VOIDS LEFT AS A RESULT OF ANY REMOVALS AND NEW CONSTRUCTION, AS WELL AS INFILL ANY EXISTING VOIDS IN NEWLY DESIGNATED FIRE RATED PARTITIONS. ALL PATCHES SHALL MATCH AND ALIGN WITH SURROUNDING MATERIALS AND SHALL BE
IN ACCORDANCE WITH NFPA CODE.
9. REFER TO NEW ARCHITECTURAL FLOOR PLANS FOR PARTITION TYPE DESIGNATIONS.
10. CONTRACTOR SHALL SEAL PARTITION WALLS AROUND ALL M.E.P. PENETRATIONS OR OPENINGS, RESULTING FROM M.E.P. INSTALLATIONS
INCLUDING BUT NOT LIMITED TO THE SLAB, ABOVE AND BELOW CEILINGS.
11. ALL NEW MASONRY WORK INCLUDING NEW PARTITIONS, INFILL AND PATCHING; MATCH EXISTING COURSING AND TOOTH IN WITH EXISTING
ADJACENT CONSTRUCTION.
12. NO EXISTING FIREPROOFING IS TO BE REMOVED FROM EXISTING BUILDING STRUCTURE FOR ANY NEW INSTALLATION FOR ANY REASON.
13. IN AREAS OF TOILET ROOMS AND OTHER PLUMBING FIXTURES SUCH AS MOP BASINS, SINKS, SHOWERS, TOILETS, ETC. A TYPE 'X' MOISTURE RESISTANT GYPSUM WALLBOARD SHALL BE USED FOR THE WALL CONSTRUCTION. WHERE CERAMIC TILE IS SCHEDULED; CEMENTITIOUS BOARD
SHALL BE USED FOR THE WALL CONSTRUCTION.
14. UNLESS NOTED, THE CONNECTION AT THE TOP OF THE PARTITION TO THE STRUCTURE ABOVE MUST ALLOW FOR 1" MINIMUM VERTICAL MOVEMENT, EITHER UP OR DOWN. AT FIRE RATED METAL STUD PARTITIONS, THE TOP CONNECTION MUST BE A FIRE STOP CONNECTION THAT ALLOWS 1" MINIMUM VERTICAL MOVEMENT, EITHER UP OR DOWN. HOLD GYPSUM WALL BOARD AND STEEL STUDS 1" FROM THE BOTTOM OF THE STRUCTURE ABOVE. DO NOT SCREW-ATTACH STEEL VERTICAL STUDS OR GYPSUM WALL BOARD TO THE TOP TRACK. INSTALL BRIDGING 12"
MINIMUM FROM THE TOP OF THE STUDS.
P A R T I T I O N N O T E S :
ABBREVIATIONS
A.D.
A.C.T.
ACOUS.
A/C
A.C.P.
A.B.
AREA DRAIN
ACOUSTICAL CEILING TILE
ACOUSTIC
AIR CONDITIONING
ASPHALT CONCRETE
ANCHOR BOLT
PAVING
POUND OR NUMBER
PROPERTY LINE
FLOOR LINE
ANGLE
DIAMETER
CENTERLINE
AT
AND
BD.
APPROX.
ARCH.
ASPH.
ALT.
AL.
AGG.
BLDG.
BLK.
BLKG.
BM.
BRG.
BRK.
BOT.
BITUM.
CEM.
C.B.
CARP.
CAB.
B.U.R.
BTWN.
CLKG.
CLG.J.
CLG.
C.J.
CIR.
C.I.
CER.T.
CER.
BRZ.
COMB.
COL.
C.O.
CNTR.
CMU
CLS.
CLR.
C.W.
CTR.
CONV.O.
CONT.
CONST.
CONN.
CONC.
COMP.
DF.
D.F.
DIAG.
DIA.
DIM.
DISP.
DET.
DN.
D.O.
DR.
D.S.
D.T.
D.W.
DWR.
DIV.
CLO.
DOUGLAS FIR
DRINKING FOUNTAIN
DIAMETER
DIAGONAL
DIMENSION
DISPOSAL
DIVISION
DOWN
DOOR OPENING
DOOR
DOWN SPOUT
DRAIN TILE
DISHWASHER
DRAWER
DETAIL
COLD WATER
CENTER
CONVECTION OVEN
CONTINUOUS
CONSTRUCTION
CONNECTION
CONCRETE
COMPOSITION
BENCH MARK or BEAM
BOARD
BITUMINOUS
BUILDING
BLOCK
BLOCKING
APPROXIMATE
ARCHITECT
ASPHALT
CONCRETE MASONRY
COMBINATION
COLUMN
CLEAN OUT
COUNTER
CLOSURE
CLEAR
CLOSET
CAULKING
CEILING JOIST
UNIT
CEILING
BRICK
BEARING
CONSTRUCTION JOINT
CIRCLE
CAST IRON
CERAMIC TILE
CERAMIC
CEMENT
CATCH BASIN
CARPET
CABINET
BUILT-UP ROOFING
BETWEEN
BRONZE
BOTTOM
ALTERNATE
ALUMINUM
AGGREGATE
EA.
E.E.
E.F.
E.J.
ELEC.
ELEV.
E.N.
EXISTING
EACH
EACH END
EXHAUST FAN
EXPANSION JOINT
ELECTRICAL
ELEVATION
EDGE NAIL
(E)
ADJUSTABLEADJ.
LP
LC
LF
Ø
ABOVE FINISH FLOORAFF
CONTRACTOR FURNISH/
OWNER INSTALL
C.F.O.I.
C.F.C.I. CONTRACTOR FURNISH/
CONTRACTOR INSTALL
E.C. ELECTRICAL CONTRACTOR
C.HK. COAT HOOK
C.B.B. CEMENTITIOUS BACKER
BOARD
A.C.M. ASBESTOS CONTAINING
MATERIALS
CW. CURTAINWALL
DWG(S). DRAWING(S)
FACE OF BUILDINGF.O.B.
FIXTURE
FACE OF CONCRETE
FLOOR
FLOOR JOIST
FLOOR LINE
FLASHING
FACE NAIL
GAUGE
FOOTING
FUTURE
FACE OF STUD
FIRE RETARDANT
TREATED WOOD
FACE OF MASONRY
FACE OF FINISH
F.O.S.
F.R.T.W.
FTG.
FUT.
GA.
FIXT.
F.J.
F.L.
FLASH.
FLR.
F.N.
F.O.C.
F.O.F.
F.O.M.
BEAM
GLASS
GLUE LAMINATED
GALVANIZED IRON
GRATE ELEVATION
GRAB BAR
GARBAGE DISPOSAL
GRADE
HOSE BIB
SHEET METAL
GYPSUM BOARD
HANDICAPPED
GALVANIZED
GROUND
HC.
GYP.BD.
H.B.
G.B.
G.D.
G.S.M.
GR.
GND.
GLB.
GL.
G.I.
G.E.
HEIGHT
HOUR
HEATING
HIGH POINT
HORIZONTAL
HOLLOW METAL
HARDWARE
HARDWOOD
INTERIOR
INVERT
HOT WATER
INSULATION
INSIDE DIAMETER
& AIR CONDITIONING
HEATING, VENTILATION
H.W.
INV.
INT.
INSUL.
I.D.
HDWE.
HDWD.
H.V.A.C.
HTG.
HR.
H.P.
HORIZ.
H.M.
HGT.
HDR. HEADER
JOIST
JANITOR
KITCHEN
JOINT
LABORATORY
JOIST HANGER
LAG BOLT
LAVATORY
LAMINATE
J.H.
JAN.
L.B.
LAV.
LAM.
LAB.
KIT.
JT.
JST.
EQUIV.
E.S.
E.W.
EXP.
EXP.B.
EXPO.
EXT.
F.
ENCL.
F.B.
F.BD.
F.BELL
F.B.O.
F.D.
FDN.
F.E.
FH.M.S.
F.HORN
F.F.
F.G.
FGL.
F.H.
F.E.C.
F.A.
FH.W.S.
FIN.
F.H.S.
ENCLOSURE
EQUIVALENT
EACH SIDE
EACH WAY
EXPANSION
EXPANSION BOLT
EXPOSURE
EXTERIOR
FLAT HEAD MACHINE
SCREW
SCREW
FIRE HORN
FIRE HOSE STATION
FLAT HEAD WOOD
FINISH
FLOOR DRAIN
FOUNDATION
FIRE EXTINGUISHER
FIRE EXTINGUISHER
FINISH FLOOR
FINISH GRADE
FIBERGLASS
FIRE HYDRANT
CABINET
FIRE ALARM
FACE BRICK
FIREBOARD
FIRE BELL
FURNISHED BY OTHERS
FACE
GALV. GALVANIZED
HOLLOW STRUC. STL.H.S.S.
FLUORESCENTFLOUR.
GENERAL CONTRACTORG.C.
E.W.C. ELECTRIC WATER CLOSET
FIRE VALVE CABINETF.V.C.
FOOD SERVICE EQUIPMENT
CONTRACTOR
F.S.E.C.
H.V.A.C. CONTRACTORH.C.
FIRE SUPPRESSION
CONTRACTOR
F.S.C.
PLASTIC LAMINATEP.LAM.
O.H.W.S.
SCREW
OVAL HEAD WOOD
APPROVAL)
PAPER TOWEL DISPENSER
PAPER TOWEL
PARTITION
DOUGLAS FIR
PRESSURE TREATED
REFLECTED CEILING
RADIUS
RUBBER BASE
QUARRY TILE
POLYVINYL-CHLORIDE
RECEPTACLE
R.C.P.
Q.T.
RAD.
R.B.
P.T.D.
PTN.
P.T.R.
P.V.C.
P.T.D.F.
REDWOOD
REFERENCE
REINFORCING
ROOF HATCH
ROUND HEAD METAL
RESILIENT
REFRIGERATOR
ROOF DRAIN
SCREW
ROOM
RAIN WATER LEADER
ROUGH OPENING
ROUND HEAD WOOD
SCREW
RDWD.
R.H.W.S.
R.W.L.
R.O.
RM.
R.H.M.S.
R.H.
RESIL.
REINF.
REFR.
REF.
R.D.
LIGHT
MATERIAL
LOW POINT
LIVE LOAD
LEFT HAND
MAT.
LT.
L.P.
L.L.
L.H.
MANHOLE
MINIMUM
MEDIUM
MANUFACTURER
MEMBRANE
MECHANICAL
MEDICINE CABINET
MACHINE BOLT
METAL
MASONRY OPENING
METAL THRESHOLD
MISCELLANEOUS
MODULAR
MOISTURE RESISTANT
MIRROR
M.C.
M.B.
MIN.
MH.
MFG.
MEMB.
MED.
MECH.
MIR.
MISC.
M.O.
MOD.
M.R.
M.T.
MTL.
MAX. MAXIMUM
NORTH
NATURAL
OVER
NUMBER
NOMINAL
NOT TO SCALE
NOT IN CONTRACT
OBSCURE
OUTSIDE DIAMETER
STUD
OFFICE
OUTSIDE FACE OF
ON CENTER
OVERFLOW
OVERALL
N.T.S.
O/ O.A.
OBS.
O.C.
O.D.
O.F.
OFF.
O.F.S.
(NOT PART OF OSA
N.
NAT.
N.I.C.
NO.
NOM.
PAINT
PLATE
PERFORATED
FOOT
POUNDS PER CUBIC
PANEL EDGE NAILING
PRESSED METAL
PAIR
FRAME
FOOT
POUNDS PER LINEAR
PLYWOOD
POUNDS PER SQUARE
PROPERTY
PLASTER
P.
P.C.F.
P.E.N.
PERF.
PL.
PLAS.
P.L.F.
PLYWD.
P.M.F.
PR.
P.S.F.
PROP.
OPP. OPPOSITE
POINT
PULL STATION
POUNDS PER SQUARE
INCH
P.STA.
PT.
P.S.I.
FOOT
(N) NEW
PLAN
REQUIREDREQD.
NON-COMBUSTIBLENON/COM
PLUMBING CONTRACTORP.C.
MECHANICAL, ELECTRICAL,
PLUMBING
M.E.P.
FRAMED MIRRORMR.
ROBE HOOKR.HK.
MOP HOLDERMP.H.
MOUNTEDMTD.
PAINTEDPTD.
TONGUE AND GROOVE
DRAWINGS
SOUTH
SEE CIVIL DRAWINGS
STORM DRAIN
SOLID CORE WOOD DOOR
DRAWINGS
SHEET
SIMILAR
SLIDING
SHEATHING
SHOWER
SECTION
SEALANT
SEE ELECTRICAL
SOLID BLOCKING
SOAP DISPENSER
SEE ARCHITECTURAL
S.E.D.
SHR.
SHT.
SIM.
SL.
SHTG.
S.BLKG.
S.A.D.
S.
SECT.
SEAL.
S.DISP.
S.D.
S.C.D.
SCWD
SQUARE
DRAWINGS
SPECIFICATION
SOUNDPROOF
DRAWINGS
STATION
STEEL
STORAGE
STANDARD
SUSPENDED
STRUCTURAL
DRAWINGS
STAINLESS STEEL
SEE MECHANICAL
SANITARY SEWER
SEE STRUCTURAL
SQUARE FOOT (FEET)
THICK
TEMPERED
TELEPHONE
TERRAZZO
TACKBOARD
TOP OF CURB
TRANSOM
TOP OF PLATE
TOP OF WALL
TOILET PAPER DISPENSER
TOE NAIL
TOOL JOINT
TOP OF PAVEMENT
TOP AND BOTTOM
T.O.C.
T.O.P.
T.O.PL.
T.O.W.
T.P.D.
TRN.
S.M.D.
SPEC.
S.P.
SQ.
S.S.D.
S. STL.
STO.
STL.
STD.
STA.
S.S.
SQ. FT.
T.B.
T&B.
TEL.
TEMP.
TER.
T&G.
SUSP.
T.J.
T.N.
THK.
STRUC.
S.L.D. SEE LANDSCAPE
TYPICAL
UNLESS NOTED OTHERWISE
URINAL
UNFINISHED
TELEVISION
VENT TO ROOF
VERTICAL
VESTIBULE
VERIFY IN FIELD
VINYL TILE
VINYL COMPOSITION
TILE
VERTICAL GRAIN
WEST
WITH
WINDOW
WOOD
WATER CLOSET
VINYL WALL COVERING
WITHOUT
WEIGHT
YARD
WATER PROOF
WATER HEATER
WATER COOLER
WELDED WIRE FABRIC
WATER RESISTANT
W/O
W.W.F.
W.P.
W.R.
WT.
YD.
T.V.
TYP.
UNF.
U.N.O.
V.C.T.
VERT.
VEST.
V.G.
V.I.F.
UR.
V.W.C.
W.
W/
W.C.
V.T.R.
W.F.
W.H
WDW.
WD.
V.T.
T.S. TUBE STEEL
SELF ADHERED SHEET
MEMBRANE
S.A.S.M.
SELF ADHERED FLEXIBLE
FLASHING
S.A.F.F.
WITHINW/IN
UNDERSIDEU/S
SANITARY NAPKIN
DISPOSAL
S.N.D.
T.S.C.D. TOILET SEAT COVER
DISPENSER
SANITARY NAPKIN
DISPENSER
S.N.V.
TOP OF SEATT.O.S.
SOUND ATTENUATION
BATT
S.A.B.
V.A. FURNISHED / CONTRACTOR
INSTALLED
(VC)
V.A. FURNISHED AND INSTALLED(VV)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION
DOCUMENTS
Services
Engineering and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Chillicothe VA Chillicothe, OH
Renovate Student Housing Buildings 15 and 16 15
#538-19-204 W 5 Design LLC Architecture and Interior Design 515 Wyoming Ave.
Cincinnati Ohio 45215 513-376-0968
Ryan Jeter
C U s e rs
\n a te m \O n e
D ri v e
\D o c u m e n ts \F
F E
C h ill ic o th e
B n a te
.m o u ld s .r v t
/1
/2
:5
:0
A
M
GI004
PARTITION TYPES/SCHEDULES
01/05/2022 PH RRRevisions: Date:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
6/
/2
:3 9:
P
M
CONSTRUCTION
DOCUMENTS
Services
Engineering and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD FFE Inc.
Engineering and Technical Services 420 Springfield Pike Wyoming OH 45215 513-522-0956
STAMPCONSULTANT
321 4 5 6 7 8 9 10
01/05/22 DM BAMRevisions: Date:
Chillicothe VA Chillicothe, OH
Renovate Student Housing Buildings 15 and 16
#538-19-204
FE Inc.
Engineering and Technical Services
FRMF ENGINEERING, INC.
2323 W. 5TH AVENUE
SUITE 148
COLUMBUS, OH 43204
P: 614-441-9411 F: 614-388-8182
F
1TREE PROTECTION DETAIL
N.T.S.
CI1.10
CIVIL DETAILS
6" 6"
10" 16"
11-1/2"
1- 1/
2"
6"
6"
(MIN.)
END ELEVATION SIDE ELEVATION
SECTION ISOMETRIC
CLEANOUT FRAME & LID
6CLEANOUT
NOT TO SCALE
8"
*(1)
6" (M
IN
*(1)
VA
RI
AB
LE
IN
VE
RT
H
EI
GH
T
VA
RI
AB
LE
(2
24"4' (M
IN
6' (MIN.)
12' (MAX.)
ELEVATION
PLAN
4CURB RAMP
N.T.S.
WIDTH VARIES
2CONCRETE SIDEWALK
NOT TO SCALE
D+12" (MIN)
D+24" (MAX)
12"
20' MINIMUM SEEDING & MULCHING
12"
4" BEDDING
MATERIAL
TYPE A, B, OR
C BACKFILL
(TYPE B REQUIRED
WHEN TYPE A OR C
NOT SPECIFIED)
D
D+12" BEDDING
MATERIAL
TYP. TRENCH
FOR PVC
STORM & SANITARY PIPE
NOT TO SCALE
24"
5' (MIN.)
5' (M
IN
6' (MIN.)
12' (MAX.)
6' (MIN.)
12' (MAX.)
ELEVATION
PLAN
3CURB RAMP
N.T.S.
12"
12"
9PVC DRAIN BASIN
N.T.S.
8STRAW WATTLE
N.T.S.
6"
6"
1'-0"
WIDTH VARIES
INTEGRAL CURB & SIDEWALK
(FOR CURB RAMP AREAS)
NOT TO SCALE
ITEM 608, CLASS "C" CONCRETE
10RAMP
NOT TO SCALE
TRAVERSE SECTION B
LONGITUDINAL SECTION A
12"
1.875" O.D. STAINLESS STEEL…