This document package includes a federal contract opportunity solicitation and related facility drawings and specifications. The solicitation seeks solutions to provide audio visual equipment and installation services for five rooms in the 55th Crisis Action Team and Command Post facility. The requirement includes video teleconferencing capabilities compliant with the Advanced Polarization Laboratory standard. Interested parties should respond to the sources sought notice by 12 August 2022 with a capability statement not exceeding three pages. The notice specifies NAICS code 541519 for these services and provides a point of contact for responses. The facility drawings depict proposed audio visual outlet locations and device types. Specification notes cover installation requirements, coordination responsibilities, and general construction protocols.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| AV Technical Document rv1.pdf | ||
| B500_S04_AV-001.pdf | ||
| B500_S06_AV-501.pdf | ||
| B500_S05_AV-100.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BLDG BUILDING
BTUH BRITISH THERMAL UNIT PER HOUR
C CONDUIT
CAB CABINET
CATV CABLE TELEVISION
CCTV CLOSED CIRCUIT TELEVISION
CFM CUBIC FEET PER MINUTE
CL CENTER LINE
CLG CEILING
CLR CLEAR
CRAC COMPUTER ROOM AIR CONDITIONER
CV CONSTANT VOLUME
DD DOUBLE DUCT
DIAMETER
DISC DISCONNECT
DIST DISTRIBUTION
DN DOWN
DWG DRAWING
EA EXHAUST AIR
EL ELEVATION
EHC ELECTRIC HEATING COIL
EMT ELECTRICAL METALLIC TUBING
EQUIP EQUIPMENT
EXH EXHAUST
EXIST EXISTING
FA FIRE ALARM
FAA FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FB FLOOR BOX
FL FLOOR
FLA FULL LOAD AMPS
FMG FACTORY MUTUAL GLOBAL
FT FEET
PWR POWER
PVC POLYVINYL CHLORIDE
PSI POUNDS PER SQUARE INCH
PSF POUNDS PER SQUARE FOOT
PRV PRESSURE REGULATING VALVE
PP PATCH PANEL
PNL PANEL
PLBG PLUMBING
PIV POST INDICATOR VALVE
RM ROOM
RH RELATIVE HUMIDITY
REQD REQUIRED
RLFA RELIEF AIR
RA RETURN AIR
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER SUPPLY
UL UNDERWRITERS LABORATORY
UG UNDERGROUND
(TYP) TYPICAL
TV TELEVISION
TEMP TEMPERATURE
TEL TELEPHONE
TELECOM TELECOMMUNICATIONS
SWGR SWITCHGEAR
SWBD SWITCHBOARD
SW SWITCH
STD STANDARD
SS STAINLESS STEEL
SPECS SPECIFICATIONS
(SIM) SIMILAR
SCH SCHEDULE
SAN SANITARY
SA SUPPLY AIR, SOUND ATTENUATOR
KV KILOVOLT
NC NORMALLY CLOSED
MTG MOUNTING
MTD MOUNTED
MISC MISCELLANEOUS
(MIN) MINIMUM
MECH MECHANICAL
(MAX) MAXIMUM
MA MAKEUP AIR
LTG LIGHTING
LBS POUNDS
LAN LOCAL AREA NETWORK
KW KILOWATT
KVA KILOVOLT AMPERE
OC ON CENTER
OA OUTSIDE AIR
NTS NOT TO SCALE
NOM NOMINAL
NO NORMALLY OPEN
NIC NOT IN CONTRACT
NEC NATIONAL ELECTRICAL CODE
GA GAUGE
J-BOX JUNCTION BOX
HVAC HEATING, VENTILATING
HTG HEATING
HP HORSEPOWER, HEAT PUMP
HGT HEIGHT
GPM GALLONS PER MINUTE
GND GROUND
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GEN GENERATOR
GALV GALVANIZED
AND AIR CONDITIONING
ELEC ELECTRICAL
DIA
CPVC CHLORINATED POLYVINYL CHLORIDE
CT COOLING TOWER, CABLE TRAY
DX DIRECT EXPANSION
EPO EMERGENCY POWER OFF
F FIRE WATER
FCO FLOOR CLEAN OUT
FDC FIRE DEPARTMENT CONNECTION
FHC FIRE HOSE CABINET
FURN FURNISHED
FW FILTERED WATER
G GAS
GC GENERAL CONTRACTOR
HW HOT WATER
HWC HOT WATER CIRCULATING
MAU MAKEUP AIR UNIT
MBH 1000 BTU/HOUR
MXA MIXED AIR
NPW NON-POTABLE WATER
PS PLASTER SINK
PTAC PACKAGED TERMINAL AIR CONDITIONER
RO REVERSE OSMOSIS WATER
RPBFP REDUCED PRESSURE BACKFLOW
SCW SOFT COLD WATER
SM SPRINKLER MAIN, SINGLE MODE
SSS SURGEON SCRUB SINK
SSD SUB SOIL DRAIN
ST STORM
SMACNA SHEET METAL AND AIR
CONDITIONING CONTRACTORS'
T TRANSFORMER
BICSI BUILDING INDUSTRY CONSULTING
BTU BRITISH THERMAL UNIT
CB CIRCUIT BREAKER
CKT CIRCUIT
CM COMMUNICATIONS CABLE
CMP COMMUNICATIONS PLENUM CABLE
CMR COMMUNICATIONS RISER CABLE
COAX COAXIAL CABLE
EMD ESTIMATED MAXIMUM DEMAND
EMI ELECTROMAGNETIC INTERFERENCE
ER EQUIPMENT ROOM
FO FIBER OPTIC
FP FIBER PANEL
PB PULLBOX
PERP PERPENDICULAR
PBX PRIVATE BRANCH EXCHANGE
RGS RIGID GALVANIZED STEEL
TR TELECOMMUNICATIONS ROOM
TMGB TELECOMMUNICATIONS MAIN
TGB TELECOMMUNICATIONS
TBB TELECOMMUNICATIONS
T-1 TRUNK LEVEL 1
STP SHIELDED TWISTED PAIR
OUTLET ASSEMBLY
MM MULTIMODE
MLO MAIN LUGS ONLY
MDF MAIN DISTRIBUTION FRAME
MC MAIN CROSS CONNECT
MATV MASTER ANTENNA TELEVISION
OSP OUTSIDE PLANT
KCMIL THOUSAND CIRCULAR MILS
ISP INSIDE PLANT
HZ HERTZ
GEC GROUNDING ELECTRODE CONDUCTOR
SERVICE INTERNATIONAL
MUTOA MULTI USER TELECOMMUNICATIONS
GROUNDING BUSBAR
GROUNDING BUSBAR
TBBIBC TELECOMMUNICATIONS BONDING
CFH CUBIC FEET PER HOUR
SHW SOFT HOT WATER
TTB TELEPHONE TERMINAL BOARD
MERV MINIMUM EFFICIENCY REPORTING
VALUE
MOA MINIMUM OUTDOOR AIR
EOA ECONOMIZER OUTDOOR AIR
IE INVERT ELEVATION
IDF INTERMEDIATE DISTRIBUTION FRAME
IC INTERCOM
BACKBONE INTERCONNECTING
PREVENTER
NATIONAL ASSOCIATION
BONDING BACKBONE
BONDING CONDUCTOR
A
AC
ACEG
AHJ
APPROX
ASHRAE
ATS
AUX
AV
AVI
AW
AWG
BFP
AMP
ALTERNATING CURRENT
AC EQUIPMENT GROUND
AUTHORITY HAVING JURISDICTION
APPROXIMATELY
AMERICAN SOCIETY OF HEATING,
REFRIGERATING AND
AIR-CONDITIONING ENGINEERS
AUTOMATIC TRANSFER SWITCH
AUXILIARY
ACID VENT, AUDIOVISUAL
AUTOMATIC VEHICLE IDENTIFICATION
ACID WASTE
AMERICAN WIRE GAUGE
BACKFLOW PREVENTER
UTILITY SINK
UNSHIELDED TWISTED PAIR
VOLT, VENT
VOLUME DAMPER
VERTICAL
VARIABLE FREQUENCY CONTROL
VENT THROUGH ROOF
WATER, WATT
WIDE AREA NETWORK
WIRELESS ACCESS POINT
WIRE MANAGEMENT PANEL
WEATHERPROOF
WIRE SIZING AMPS
WATER SOURCE HEAT PUMP
TRANSFORMER
US
UTP
V
VD
VERT
VFC
VTR
W
WAN
WAP
WMP
WP
WSA
WSHP
XFMR
ABBREVIATIONS
AFF ABOVE FINISHED FLOOR
ALF ALUMINUM FRAME DOOR
AMERICAN SOCIETY OF
MECHANICAL ENGINEERS
STANDARD SPECIFICATIONS OF
THE AMERICAN SOCIETY FOR
ASME
ASTM
TESTING MATERIALS
AVG AVERAGE
BAS BUILDING AUTOMATION SYSTEM
BTC BONDING CONDUCTOR FOR
TELECOMMUNICATION
CLEC COMPETITIVE LOCAL
EXCHANGE CARRIER
CUSTOMER OWNER-OUTSIDE PLANT
DAS DISTRIBUTION ANTENNA SYSTEM
DP DEMARCATION POINT
DPS DOOR POSITION SWITCH
DVR DIGITAL VIDEO RECORDER
EAC ELECTRONIC ACCESS CONTROL
EC ELECTRICAL CONTRACTOR
EMS ENERGY MANAGEMENT SYSTEM
FM FACTORY MUTUAL
ENGINEERING CORPORATION
FOV FIELD OF VIEW
HH HANDHOLE
HMF HOLLOW METAL FRAME DOOR
IDC INSULATION DISPLACEMENT
CONNECTOR
IDS INTRUSION DETECTION SYSTEM
IP INTERNET PROTOCOL
LEC LOCAL EXCHANGE CARRIER
LBM LATCH BOLT MONITOR
MCB MAIN CIRCUIT BREAKER
MPOE MAIN POINT OF ENTRANCE
NATIONAL FIRE PROTECTION
ASSOCIATION
MANUFACTURERS ASSOCIATION
NATIONAL ELECTRICALNEMA
NFPA
NVE NETWORK VIDEO ENCODER
NVR NETWORK VIDEO RECORDER
OR OPERATOR ROOM
OPE OWNER PROVIDED ELECTRONICS
PABX PRIVATE AUTOMATIC
BRANCH EXCHANGE
PBO PROVIDE BY OTHERS
PDU POWER DISTRIBUTION UNIT
PIC PLASTIC INSULATED CABLE
POE POWER OVER ETHERNET
POP POINT OF PRESENCE
PSTN PUBLIC SWITCH TELEPHONE NETWORK
PTZ PAN-TILT-ZOOM
RQE REQUEST TO EXIT
SCTP SCREENED TWISTED PAIR
SLAB SEALED LEAD ACID BATTERY
SSI SECURITY SYSTEMS INTEGRATOR
TC TELECOMMUNICATIONS CLOSET
TVSS TRANSIENT VOLTAGE SURGE
SUPPRESSION
VOICE OVER INTERNET PROTOCOLVOIP
WIRE TRANSFER HINGEWTH
CO-OSP
SPD SURGE PROTECTIVE DEVICE
WATER GUAGEWG
SYMBOLS INDICATED HERE AND NOT USED IN THE
CONTRACT DOCUMENTS DO NOT APPLY TO THIS
PROJECT. ADDITIONAL SYMBOLS AND ABBREVIATIONS
MAY BE INDICATED IN THE CONTRACT DOCUMENTS.
AUDIOVISUAL SYMBOLS
DESCRIPTIONSYMBOLSYMBOL DESCRIPTION SYMBOL DESCRIPTION
AUDIOVISUAL
AV WALL OUTLET
("#" INDICATES DEVICE TYPE IN SCHEDULE)
CALL IN SWITCH WALL MICROPHONE OUTLET
("#" INDICATES DEVICE TYPE IN SCHEDULE)
FLOOR MICROPHONE OUTLET
("#" INDICATES DEVICE TYPE IN SCHEDULE)
PROJECTOR
("#" INDICATES DEVICE TYPE IN SCHEDULE)
AV CEILING OUTLET
("S/F" INDICATES SURFACE OR FLUSH MOUNTED
"#" INDICATES DEVICE TYPE IN SCHEDULE)
WALL/SURFACE MOUNTED LOUDSPEAKER
("#" INDICATES DEVICE TYPE IN SCHEDULE)
WALL MOUNTED FLAT PANEL DISPLAY
("#" INDICATES DEVICE TYPE IN SCHEDULE)
FRONT/REAR PROJECTION SCREEN
OR INTERACTIVE WHITEBOARD
("#" INDICATES DEVICE TYPE IN SCHEDULE)
FLOOR AV OUTLET
("#" INDICATES DEVICE TYPE IN SCHEDULE)
VOLUME CONTROLTELEVISION/VIDEO OUTLET
GROUND/FLOOR MOUNTED LOUDSPEAKER
("#" INDICATES DEVICE TYPE IN SCHEDULE)
CEILING MOUNTED LOUDSPEAKER
("#" INDICATES DEVICE TYPE IN SCHEDULE)
CEILING MOUNTED FLAT PANEL DISPLAY
("#" INDICATES DEVICE TYPE IN SCHEDULE)
TV
AV
C
AV
S #
V
M
M
AV
S/F,#
S #
S
AV ROOM SCHEDULER
("#" INDICATES DEVICE TYPE IN SCHEDULE)
AV CONTROL PANEL
("#" INDICATES DEVICE TYPE IN SCHEDULE)
AV CAMERA
("#" INDICATES DEVICE TYPE IN SCHEDULE)
RS
CP
AV CEILING BACKBOX, ("#" INDICATES TYPE IN
SCHEDULE) ("#D" INDICATES # OF DATA CABLES)#,D
AV BACKBOX, ("#" INDICATES TYPE IN SCHEDULE)
("#D" INDICATES # OF DATA CABLES) #
AV
DESCRIPTIONSYMBOLSYMBOL DESCRIPTION SYMBOL DESCRIPTION
SUBSCRIPTS
SUBSCRIPT "E" ADDED TO ANY SYMBOL
INDICATES EXISTING
SUBSCRIPT "PD" ADDED TO ANY FLOOR OUTLET
INDICATES PEDESTAL MOUNTED
SUBSCRIPT "K" ADDED TO ANY SYMBOL
INDICATES KEY OPERATED
SUBSCRIPT "WG" ADDED TO ANY SYMBOL
INDICATES WIRE GUARD
SUBSCRIPT "P" ADDED TO ANY SYMBOL
INDICATES PILOT LIGHT
SUBSCRIPT "NL" ADDED TO ANY SYMBOL INDICATES AN
UNSWITCHED LUMINAIRE OPERATING AS A NIGHT LIGHT
SUBSCRIPT "AC" ADDED TO ANY SYMBOL INDICATES ABOVE COUNTER. LOCATE CENTER OF DEVICE 4" ABOVE COUNTER SURFACE OR WHERE PRESENT, 4" ABOVE BACKSPLASH.
WHERE INDICATED ADJACENT TO LAVATORY WITHOUT COUNTER, LOCATE CENTER OF DEVICE 8" ABOVE RIM OF LAVATORY.
EP
E
PD
AC
K
WG
P
RT WP
SUBSCRIPT "RT" APPLIED TO ANY SYMBOL
INDICATES RAIN TIGHT NEMA 3R
OR EQUIVALENT
SUBSCRIPT "WP" APPLIED TO ANY SYMBOL
INDICATES WEATHERPROOF NEMA TYPE 4
OR EQUIVALENT
SUBSCRIPT "EP" APPLIED TO ANY SYMBOL
INDICATES EXPLOSION PROOF,
CLASS, GROUP AND DIVISION AS NOTED
NL
CONSTRUCTION CABLING NOTES:
A/V CABLING NOTES:
AUDIO VIDEO GENERAL NOTES
AutoCAD SHX Text
1. CABLE DAMAGED DURING ITS INSTALLATION WILL NOT BE ACCEPTED. UNLESS OTHERWISE ALLOWED BY OWNER, THE CABLE DAMAGED DURING ITS INSTALLATION WILL NOT BE ACCEPTED. UNLESS OTHERWISE ALLOWED BY OWNER, THE CONTRACTOR SHALL REPLACE CABLE DAMAGED DUE TO ITS INSTALLATION WITH NEW CABLE INSTALLED AT THE EXPENSE OF THE CONTRACTOR. DAMAGE INCLUDES PHYSICAL DAMAGE TO CABLE OR IMPROPER INSTALLATION PRACTICES THAT MAY AFFECT PERFORMANCE. 2. CABLING SHALL BE TERMINATED IN NUMERICAL ORDER BASED ON OUTLET NUMBERING. CABLING SHALL BE TERMINATED IN NUMERICAL ORDER BASED ON OUTLET NUMBERING. 3. COORDINATE MOUNTING HEIGHTS AND FINAL LOCATION OF ALL OUTLETS WITH ARCHITECT PRIOR TO ROUGH-IN.COORDINATE MOUNTING HEIGHTS AND FINAL LOCATION OF ALL OUTLETS WITH ARCHITECT PRIOR TO ROUGH-IN.
AutoCAD SHX Text
1. ALL DEBRIS RESULTING FROM PENETRATIONS SHALL BE CLEARED AND REMOVED FROM SITE ON A DAILY BASIS. ALL DEBRIS RESULTING FROM PENETRATIONS SHALL BE CLEARED AND REMOVED FROM SITE ON A DAILY BASIS. 2. ALL MATERIALS AND SURFACES TO REMAIN SHALL BE PROTECTED. IF SUCH MATERIALS AND SURFACES ARE DAMAGED DURING ALL MATERIALS AND SURFACES TO REMAIN SHALL BE PROTECTED. IF SUCH MATERIALS AND SURFACES ARE DAMAGED DURING CONSTRUCTION, REPAIR AND FINISH TO MATCH ORIGINAL CONDITIONS. EQUIPMENT, AND FURNISHINGS SHALL BE PROTECTED WHERE CONSTRUCTION WILL CAUSE DUST, DEBRIS, AND POSSIBLE DAMAGE. 3. CARE SHALL BE EXERCISED WHEN REMOVING OR REPLACING SUSPENDED CEILING PANELS. DAMAGED PANELS SHALL BE CARE SHALL BE EXERCISED WHEN REMOVING OR REPLACING SUSPENDED CEILING PANELS. DAMAGED PANELS SHALL BE REPLACED WITH NEW PANELS. ALL CEILINGS SHALL BE RETURNED TO ORIGINAL OR BETTER CONDITION. PAINT, CLEAN, AND REPLACE CEILING PANELS AS NECESSARY. DO NOT LEAVE FINGERPRINTS ON PANELS. 4. ANY STAGING AREA USED BY CONTRACTOR SHALL BE RETURNED TO ORIGINAL CONDITION TO OWNER'S SATISFACTION. ANY STAGING AREA USED BY CONTRACTOR SHALL BE RETURNED TO ORIGINAL CONDITION TO OWNER'S SATISFACTION. CONTRACTOR SHALL ARRANGE WITH THE GENERAL CONTRACTOR TO OBTAIN WORK TRAILER, MATERIAL STORAGE AND STAGING AND PARKING SPACE IF NEEDED. THE CONTRACTOR SHALL PROVIDE WORK TRAILER, SECURE STORAGE SPACE, PHONE LINES AND ANY OTHER SERVICE DEEMED NECESSARY. THE OWNER WILL NOT PROVIDE ANCILLARY SERVICES AT THE CONSTRUCTION SITE. 5. FIRESTOP ALL FLOOR, TRAY, AND WALL PENETRATIONS. FIRESTOP ALL FLOOR, TRAY, AND WALL PENETRATIONS. 6. GROUND AND BOND CABLE TRAYS WITH #6 AWG BARE COPPER WIRE UTILIZING CABLE TRAY MANUFACTURER'S RECOMMENDED GROUND AND BOND CABLE TRAYS WITH #6 AWG BARE COPPER WIRE UTILIZING CABLE TRAY MANUFACTURER'S RECOMMENDED HARDWARE TO MAINTAIN GROUND CONTINUITY.
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text M
AutoCAD SHX Text B
AutoCAD SHX Text N
AutoCAD SHX Text D
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text Offutt
AutoCAD SHX Text Air Force Base
AutoCAD SHX Text
COORDINATION
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SIGNATURE
AutoCAD SHX Text
ALL DRAWINGS IN THIS PROJECT;
AutoCAD SHX Text
SUBSEQUENT SHEETS NEED NOT
AutoCAD SHX Text
BE SIGNED"
AutoCAD SHX Text
CONSTITUTES COORDINATION OF
AutoCAD SHX Text
"SIGNING OF THE COVER SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
SHEET TITLE
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text Facility Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text
DESIGN FIRM
AutoCAD SHX Text Designer
AutoCAD SHX Text Project Manager
AutoCAD SHX Text Date
AutoCAD SHX Text Drafter
AutoCAD SHX Text
BY/DATE
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
TJB
AutoCAD SHX Text
JLH
AutoCAD SHX Text
RAW
AutoCAD SHX Text
07 DEC 20
AutoCAD SHX Text
KHA NO. 102-061 FFE
AutoCAD SHX Text B500
AutoCAD SHX Text
NC3, CP/CAT,
AutoCAD SHX Text
2F WING, B500
AutoCAD SHX Text
AutoCAD SHX Text
SGBP 18-0041
AutoCAD SHX Text
OFF-B-6449
AutoCAD SHX Text
F.F.E. WITH A.V.
AutoCAD SHX Text
100%%% SUBMITTAL
AutoCAD SHX Text DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS AND CLEARANCES FROM ARCHITECTURAL, STRUCTURAL, SHOP AND OTHER APPROPRIATE DRAWING OR AT SITE. LAY OUT AND COORDINATE ALL WORK PRIOR TO INSTALLATION TO PROVIDE CLEARANCES REQUIRED FOR OPERATION, MAINTENANCE, AND CODES AND VERIFY NON-INTERFERENCE WITH OTHER WORK. DO NOT FABRICATE PRIOR TO VERIFICATION OF CLEARANCE FOR ALL TRADES. READ SPECIFICATIONS.
AutoCAD SHX Text
AUDIOVISUAL SYMBOLS AND ABBREVIATIONS
AutoCAD SHX Text
AV-000
AutoCAD SHX Text
| Sheets and Views |
| 3 of 6 (AV-000)-3 of 6 (AV-000) |