B2750 Classroom Network Consoles Statement of Requirements (SOR).pdf

PDF 93 KB Posted

Attached to
Test Pilot School (TPS) B2750 Classroom Network Consoles
Solicitation number
PZZDTPS250031
Issued by

About this file

This document is a Statement of Requirements (SOR) for the fabrication and installation of classroom consoles that allow for IT integration into the back of the desks for the US Air Force Test Pilot School (TPS) in Building 2750. The SOR outlines the technical, security, and console requirements, including the specific equipment that must be accommodated per user station. It specifies that the consoles must be TAA compliant, manufactured in the United States, and meet SCIF/SAPF, NIPR/SIPR, TEMPEST, and JWICS requirements. The consoles must be designed to fit 36 users in a classroom row configuration within a 31ft x 42ft room. The vendor must deliver and install the consoles by January 18, 2024.

The related federal contract opportunity is a pre-solicitation announcement for the fabrication and installation of the classroom consoles described in the SOR. The Department of the Air Force Materiel Command Test Center is conducting market research to identify potential contractors. Responses to this announcement are not offers, and the government is under no obligation to award a contract as a result.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF REQUIREMENTS

US Air Force Test Pilot School (TPS) B2750 Classroom Network Consoles

Current as of 1 October 2024

1. SCOPE:

The government requires the fabrication and installation of classroom consoles that allow for IT integration into the back of the desks. This will allow for SCIF security and IT requirements to be met.

2. REQUIREMENT:

• Technology Requirements o Rack in the back of desks must be able to be customizable and fit the following equipment per user:

1 – Mirage B3000S (NIPR) Small Form Factor PC 2 – HP Z2 G9 Mini (or other Mini Form Factor PC) - (JWICS/SGN) 1 – Belkin Secure KVM F1DN204KVM-UN-4 2 – Surge Protectors (1 to connect Unclassified equipment / 1 for

Classified Equipment) o Top Surface of Console must fit the following equipment per user

1 – 24” Monitor - LG 24BL450YB001 Mouse Keyboard No data or power grommets on surface No task lights o Power at each station under the work surface

• Security Requirements o Must be TAA compliant and manufactured in the United States per SCIF/SAPF requirements.

o NIPR/SIPR Requirements o TEMPEST Requirements o JWICS Requirements o Must have cable/network separation

• Console Requirements o Simple, straight edge design o Consoles/Design need to fit 36 users in a classroom ‘row’ configuration

Room is 31ftx42ft 3ft wide per user. 6 users per row. 6 rows in total.

Desks will be facing projectors and whiteboards along the 42ft wall o Work surface must be 24in-30in deep o Pole or other VESA mount option for the monitors to maximize limited surface space.

o Rack space in the back needs a minimum of at least 7” depth to accommodate our SFF NIPR PC.

o Rack space in the back has slat wall to mount the PC’s and KVM.

3. SPECIFICATIONS:

• The vendor shall fabricate and install all furniture into the appropriate classroom space on the second floor, room 104 of building 2750.

• See attached concept diagram

4. DELIVERY:

Liftgate required. The contractor shall deliver all furniture that meet the above requirements no later than 18 January 2024. Delivery address will be provided upon award.

Items, when delivered, will be accepted and inspected by the government officials responsible for receiving the products and performing any required inspections.

There is a delivery dock but no forklift at the site location.

File details come from the government source that posted it. Updated .