This is a comprehensive architectural design and window replacement project document for Baraga Area Schools, located at 210 Lyons Street in Baraga, Michigan. The project involves a complete window replacement across five designated areas (Areas A-E) of the school complex, including the vocational education building. The base bid includes replacing existing exterior windows, window frames, and interior windowsills with new windows, and installing ballistic window film on all windows. An alternate bid (Bid Alt #1) provides an option to remove existing blinds and curtains and replace them with new manual roller shades.
The project specifications detail precise requirements for window installation, including using aluminum windows with tempered glass and security film, maintaining existing aluminum color schemes, and ensuring proper installation with shimming, insulation, and sealant. The building is classified as an Educational (E) use group with Type II-B, unprotected, non-combustible fire ratings. The total building area is 80,000 square feet, with 18 doors providing egress. The project documents include detailed demolition plans, floor plans, exterior elevations, and window type specifications, with a focus on removing approximately 225 square feet of asbestos-laden material from windowsills. The project is scheduled for review on September 11, 2025, with contractors required to verify existing measurements and conditions prior to window replacement.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| B163-5400_BAS Window Replacement_LARA Review_2025.09.11 (1).pdf | ||
| Window documents.pdf | ||
| Window documents (1).pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ZONING: FED - FEDERAL / STATE FOREST / TRIBAL
BUILDING CODE REVIEW
2021 MICHIGAN BUILDING CODE & MICHIGAN BARRIER FREE
2021 MICHIGAN MECHANICAL CODE
2021 MICHIGAN PLUMBING CODE
2021 MICHIGAN ENERGY CODE
2023 NATIONAL ELECTRIC CODE
2023 MICHIGAN ELECTRICAL CODE, PART 8
USE GROUP: E - EDUCATIONAL
FIRE RATINGS: TYPE II-B, UNPROTECTED, NON-COMBUSTIBLE
FIRE PROTECTION: NOT SPRINKLERED
PROJECT DESCRIPTION:
• BASE BID: REPLACE EXISTING EXTERIOR WINDOWS, WINDOW FRAMES, &
INTERIOR WINDOWSILLS, AND REPLACE THEM WITH NEW WINDOWS,
FRAMES AND INTERIOR WINDOWSILLS. PROVIDE BALLISTIC WINDOW FILM,
TYPICAL ON ALL WINDOWS.
• BID ALT #1: REMOVE ALL EXISTING BLINDS & CURTAINS AND REPLACE
THEM WITH NEW ROLLER SHADES.
EXTERIOR WALLS: BRICK VENEER / MASONRY (NOT RATED)
INTERIOR WALLS: MASONRY (NOT RATED)
FIRE ALARM PROVIDED THROUGHOUT
BUILDING AREA (GROSS): 80,000 SQ. FT.
EGRESS PROVIDED: (18) DOORS x 33" = 594"
MAX. TRAVEL DISTANCE: 200' - 0" WITHOUT SPRINKLER SYSTEM
33 G5
30 65
17 139
55 52
32 180
14 12
CEDARVILLE
HESSEL
WHITEFISH
POINT
SAULT
STE
MARIE
NATIONAL PARK
ISLE ROYALE
NORWAY
MARENISCO
WHITE PINE
BERGLAND
NEWBERRY
SILVER
CITY
BESSEMER
IRONWOOD
WAKEFIELD
GREEN BAY
GWINN
HERMANSVILLE
MENOMINEE
IRON MOUNTAIN
VULCAN
CASPIAN
TROUT
WATERSMEET
CREEK
CROSSING
MASS
CITY
BRUCE
ONTONAGON
ROCKLAND BARAGA
ARNHEIM
CRYSTAL
FALLS
ISHPEMING
MICHIGAMME
L'ANSE
AURA
SKANEE
MARQUETTE
NEGAUNEE
MANISTIQUE
ESCANABA
FAYETTE
GARDEN
MUNISING
CURTIS
CITY
GOULD
HARBOR
CALUMET
RIPLEYHOUGHTON
CHASSELL
HANCOCK
DELAWARE
LAKE
LINDEN
LAURIUM
EAGLE
HARBOR
COPPER
MACKINAC
ISLAND
IGNACE
ST
INDIAN
RIVER
CHEBOYGAN
MACKINAW CITY
PELSTON
ONAWAY
GAYLORD
PETOSKEY
CHARLEVOIX
MANCELONA
KALKASKA
TRAVERSE
CITY
EMPIRE
ELBERTA
ARCADIA
MANISTEE
SCOTTVILLE
BALDWINLUDINGTON
SHELBY
BIG RAPIDS
MOUNT
PLEASANT
CADILLAC
GRAYLING
EAST
TAWAS
ROSCOMMON
LACHINE ALPENA
WOLVERINE
ATLANTA
ROGERS CITYALANSON
CROSS
VILLAGE
BOYNE CITY
BELLAIRE
JORDAN
E.
EASTPORTNORTHPORT
LELAND
BUCKLEY
FIFE
LAKE
FRANKFORT
MESICK
MANTON
BEAR
LAKE
LILLEY
HESPERIA
WHITE
CLOUD
EVART
REMUS
MIDLAND
SAGINAW
BAY
CITY
HARRISVILLE
CURRAN
MIO
OSCODA
TAWAS CITY
WEST
BRANCH
STANDISH
GLADWIN
McBAIN
LAKE CITY
CLARE
CARO
TROUT LAKE
BREVORT
IRON RIVERBRULE
WASHBURN
POPLAR
ASHLAND
PORT WING BAYFIELD
ODARRAH
MELLEN
UPSON
HURLEY
GLIDDEN
PARK FALLS
CLAM LAKE
MERCER
PRESQUE
ISLE
LAND O'LAKES
EAGLE
RIVER
PHELPS
FLORENCE
NIAGRA
CRANDON
SUPERIOR
HAYWARD
MINONG
CABLE
SHELL LAKE
GRANTSBURG
BALSAM
LAKE BARRON
MENOMONIE
DURAND
ALMA
WHITEHALL
BLACK
RIVER
FALLS
SPARTA
LA CROSSE
FRIENDSHIP
MONTELLO
WAUTOMA
GREEN
LAKE
FOND DU LAC
OSHKOSH
APPLETON
DE PERE
GREEN BAY
KEWAUNEE
STURGEON BAY
MARINETTE
OCONTO
SHAWANO
KESHENA
WAUSAU
STEVENS
POINT
WAUPACA
RHINELANDERPHILIPS
MEDFORD
MERRILL
ANTIGO
EAU CLARE
LADYSMITH
THREE
LAKES
MICHIGAN
WISCONSIN
LAKE
MICHIGAN
LAKE
SUPERIOR
HURON
LAKE
100 PORTAGE STREET
HOUGHTON, MI 49931
P (906) 482-4810 F (906) 482-9799
1 2 3 4 5
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
U.P. ENGINEERS &
ARCHITECTS, INC.
2906 N. STEPHENSON AVE, SUITE 2
IRON MOUNTAIN, MI 49801
P (906) 779-0937 F (906) 779-0947
424 S. PINE ST.
ISHPEMING, MI 49849
P (906) 485-1011 F (906) 485-1013
1701 DUNLAP AVE., SUITE 8
MARINETTE, WI 54143
P (715) 732-4188 F (715) 732-4189
707 ASHMUN STREET
SAULT STE. MARIE, MI 49783
P (906) 635-0511 F (906) 635-0612
PR
OJ
EC
T
NO
w w w .u pe a.
co m
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
IS
SU
ED
F
O R
D
AT
E:
1 2 3 4 5
C :\U se rs
\ra nd er so n\ D oc um en ts
\B
3-
_B
AS
W in do w R ep la ce m en t_
C
EN
TR
AL
_R
_r an de rs on up ea
.c om
.rv t
9/
/2
:0 0:
A
M
BARAGA AREA SCHOOLS
WINDOW REPLACEMENT
210 LYONS STREET, BARAGA, MI 49908
G001
COVER SHEET
BA
RA
GA
A
RE
A
SC
HO
OL
S
W
IN
DO
W
R
EP
LA
CE
ME
NT
0 L
YO
NS
S
TR
EE
T, B
AR
AG
A, M I 4
B1
-0
R M
A
JA R
M A
R M
A
BA
RA
G A
AR
EA
S C
H O
O
LS
W
IN
DO
W
R
EP
LA
C
EM
EN
T
PROJECT VICINITY MAP
PROJECT LOCATION
SHEET INDEX
NUMBER SHEET NAME
G001 COVER SHEET
A090 ABATEMENT DEMOLITION PLAN
A100 OVERALL DEMOLITION PLAN
A100.1 DEMOLITION PLAN - AREA A
A100.2 DEMOLITION PLAN - AREA B
A100.3 DEMOLITION PLAN - AREA C
A100.4 DEMOLITION PLAN - AREA D
A100.5 DEMOLITION PLAN - AREA E
A101 OVERALL FLOOR PLAN
A101.1 PROPOSED FLOOR PLAN - AREA A
A101.2 PROPOSED FLOOR PLAN - AREA B
A101.3 PROPOSED FLOOR PLAN - AREA C
A101.4 PROPOSED FLOOR PLAN - AREA D
A101.5 PROPOSED FLOOR PLAN - AREA E
A201 EXTERIOR ELEVATIONS
A401 WINDOW TYPES AND DETAILS
LA
RA
R
EV
IE
W
/1
1/
1 1 1 1 1 1
1 1
1 1 1 1 1
1 1 1 1 1 1 1 1
1 1 1 1 1
1 1
1 1
6 sf 6 sf 6 sf 6 sf 6 sf 6 sf
6 sf 6 sf 6 sf 6 sf 6 sf
8 sf
8 sf
8 sf
8 sf
8 sf
8 sf 8 sf 8 sf3 sf
8 sf 8 sf 8 sf 8 sf 8 sf 8 sf 8 sf
5 sf 5 sf
3 sf2 sf
3 sf
5 sf
3 sf
3 sf
3 sf 4 sf
2 sf
4 sf
ABATEMENT DEMOLITION SCOPE - KEYNOTE :
1. ALL EXTERIOR WINDOWS AND WINDOWSILLS SHALL BE INSPECTED TO DETERMINE THE
EXACT SCOPE OF WORK AND CONDITION IN ORDER FOR THE NEW WINDOWS AND
WINDOWSILLS TO BE REPLACED & RESTORED TO A SAFE CONDITION.
2. REMOVE APPROXIMATELY 225 TOTAL SQUARE FEET OF ASBESTOS LADEN MATERIAL
FROM THE WINDOWSILLS OF ALL EXISTING WINDOWS USING THE APPROPRIATE
REMOVAL METHOD IN FULL COMPLIANCE WITH ALL STATE AND LOCAL CODES.
3. CONTRACTOR SHALL PROVIDE THE NECESSARY PERMITS FOR ABATEMENT AND SHALL
COMPLY WITH ALL STATE AND LOCAL CODE REQUIREMENTS.
4. BLACK BITUMINOUS MASTIC BETWEEN THE WINDOWSILL AND THE MASONRY WALL
SHALL BE ABATED BY A CERTIFIED ASBESTOS ABATEMENT CONTRACTOR.
5. ALL ABATEMENT / REMOVAL WORK TO BE PERFORMED BY A STATE OF MICHIGAN
CERTIFIED ABATEMENT PROFESSIONAL ONLY.
A. HAZARDOUS MATERIALS LISTED / DESCRIBED ARE TO THE BEST KNOWLEDGE
OF THE ENGINEER / ARCHITECT.
B. CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER IDENTIFICATION AND
DISPOSAL OF THESE ITEMS IN ACCORDANCE WITH OSHA AND OTHER
REQUIREMENTS.
C. IF OTHER SUSPECTED HAZARDOUS MATERIALS ARE UNCOVERED DURING
DEMOLITION, CONTRACTOR SHALL HAVE MATERIALS TESTED AND / OR SHALL
HANDLE AS REQUIRED BY OSHA.
6. SEE HAZARDOUS MATERIALS TESTING REPORT IN THE SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
ASBESTOS CONTAINING MATERIAL:
-BLACK MASTIC: LOCATED BETWEEN THE WINDOWSILL AND THE MASONRY WALL. IT IS
REQUIRED THAT THIS MATERIAL BE ABATED BY A CERTIFIED ASBESTOS ABATEMENT
CONTRACTOR. THERE IS APPROXIMATELY 225 SQUARE FEET OF WINDOWSILL TO BE REMOVED.
NOTE: REFER TO SAMPLING REPORT - "ASBESTOS SURVEY & LEAD AND CADMIUM CONTAINING
PAINT SAMPLE REPORT" - FOR MORE INFORMATION.
1 5 sf
GENERAL DEMOLITION NOTES
1. CONSTRUCTION DOCUMENTS DESCRIBE TYPICAL DEMOLITION WORK. CONTRACTOR IS
RESPONSIBLE FOR PROVIDING SPECIFIC DEMOLITION WORK REQUIRED TO
ACCOMMODATE NEW WORK.
2. EXISTING STRUCTURAL SYSTEMS INCLUDING COLUMNS, BEAMS, AND STRUCTURAL WALLS
TO REMAIN UNLESS OTHERWISE INDICATED IN STRUCTURAL DOCUMENTS.
3. INSTALL STRUCTURAL SHORING (WHERE OCCURS, AND AS NEEDED) PRIOR TO
DEMOLITION AND REPLACEMENT OF EXISTING WINDOWS.
4. CONTRACTOR IS RESPONSIBLE FOR PROTECTING THE CONDITION OF THE CLASSROOM
DURING THE REPLACEMENT OF EXISTING WINDOWS.
DEMOLITION LEGEND
REMOVE EXISTING WINDOW SYSTEM.
3 sf
KEYNOTE #1 ON THIS DRAWING CLARIFIES THE SCOPE
OF WORK DELINEATED BY THE HATCH PATTERN.
SQUARE FEET OF ASBESTOS LADEN WINDOWSILL TO BE REMOVED.
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T
NO
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R
D
AT
E:
1 2 3 4 5
1 2 3 4 5
C :\U se rs
\ra nd er so n\ D oc um en ts
\B
3-
_B
AS
W in do w R ep la ce m en t_
C
EN
TR
AL
_R
_r an de rs on up ea
.c om
.rv t
9/
/2
:0 0:
A
M
A090
ABATEMENT
DEMOLITION PLAN
B
AR
AG
A
AR
EA
S C
H O
O
LS
W
IN
DO
W
R
EP
LA
CE
ME
NT
0 L
YO
NS
S
TR
EE
T, B
AR
AG
A, M I 4
B1
-0
R M
A G
P / A
K R
M A
R M
A
BA
RA
GA
A
RE
A
SC
HO
OL
S
W
IN
DO
W
R
EP
LA
CE
M
EN
T
1/16" = 1'-0"A1 OVERALL ABATEMENT DEMO PLAN
NORTH
1/16" = 1'-0"C5 SECOND FLOOR @ GYM
LA
R
A R
EV
IE
W
/1 1/
UP UP UP
UP
UP
EXISTING VOCATIONAL
EDUCATION BUILDING
V-001
A100.1 A1
A100.2 A1
A100.3 A1
A100.4 A1
1" / 1'-0"1" / 1'-0"1" / 1'-0"
CLASSROOM
108B
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
108A
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
POTTERY
STOR.
STOR.
CLASSROOM
102 LIBRARY
STORAGE
314A
VAULT
BOOK-
KEEPING
SUPT.
CENTRAL OFFICE
A.D.
VEST.
001LOBBY
CONC.
A.D.
STOR.
STOR.
GYMNASIUM
JAN.
WOMEN
MEN
015FAN
STORAGE
CORRIDOR
STORAGE
315G.E.
OFFICE
DEAN OF
STUDENTS
316A
ELEM. OFFICE
STOR.
BOYS
GIRLS
JAN.
CLASSROOM
OFFICE
204T.O.
207A
T.O.
209A
CLASSROOM
H.S. TITLE-1
K.B.I.C.
BOYS
LOCKERS
GIRLS
LOCKERS
MULTI-PURPOSE
KITCHEN
STOR.
FRZ.
320C
TLT.
DRY STOR.
320A
COOLER
320B
ELEC.
STOR.
K.B.I.C.
OFFICE
CORR.
CORR.
HEALTH
OFFICE
OFFICE
208ASTOR.
208B
COMMONS
208 CORR.
CORR.
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
STOR.
STOR.
217A
CLASSROOM
CLASSROOM
CLASSROOM
CORRIDOR
VEST.
112A
CLASSROOM
CORRIDOR
VEST.
225A
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
STOR.
CLASSROOM
WOMEN
MEN
JAN.
CORRIDOR
OFFICE
OFFICE
H.S. OFFICE
TLT.
TLT.
LOUNGE
MEETING
BOILER
RECEIVING
STOR.
GIRLS
LOCKERS
BOYS
LOCKERS
OFFICE
OFFICE
STOR.
008A
STOR.
008B
DRYING
CORRIDOR
CLASSROOM
STOR.
210A
STOR.
210B
STOR.
210C
STOR.
210D
VEST.
JAN.
STOR.
206A
AREA A
AREA B
AREA C
AREA D
A100.5
A1 AREA E
AREA A
AREA B
AREA CAREA D
AREA E
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T
NO
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R
D
AT
E:
1 2 3 4 5
1 2 3 4 5
C :\U se rs
\ra nd er so n\ D oc um en ts
\B
3-
_B
AS
W in do w R ep la ce m en t_
C
EN
TR
AL
_R
_r an de rs on up ea
.c om
.rv t
9/
/2
:0 0:
A
M
A100
OVERALL
DEMOLITION PLAN
B
AR
AG
A
AR
EA
S C
H O
O
LS
W
IN
DO
W
R
EP
LA
CE
ME
NT
0 L
YO
NS
S
TR
EE
T, B
AR
AG
A, M I 4
B1
-0
R M
A
JA R
M A
R M
A
BA
RA
GA
A
RE
A
SC
HO
OL
S
W
IN
DO
W
R
EP
LA
CE
M
EN
T
NORTH
1/16" = 1'-0"1 OVERALL FLOOR PLAN
NO SCALE- KEY PLAN
LA
R
A R
EV
IE
W
/1 1/
22222
2 2 2 2 2 2
R.O. 12'-0"W x 5'-0"H
R.
O.
5'-
0" W x 6'-
0" H
R.O. 12'-0"W x 5'-0"HR.O. 12'-0"W x 5'-0"HR.O. 12'-0"W x 5'-0"HR.O. 12'-0"W x 5'-0"H
R.O. 12'-0"W x 5'-0"H R.O. 12'-0"W x 5'-0"H R.O. 12'-0"W x 5'-0"H R.O. 12'-0"W x 5'-0"H R.O. 12'-0"W x 5'-0"H R.O. 12'-0"W x 5'-0"H
R.
O.
'-0
"W x
'-4
"H
R.
O.
'-0
"W x
'-4
"H
1 1 1 1 1 1
11111
333333
3 3 3 3 3
A201
D3
DEMOLITION KEYNOTES -
1 REFER TO A090 - ABATEMENT DEMOLITION PLAN FOR REMOVAL OF ASBESTOS LADEN
WINDOWSILLS AND ADHESIVE.
2 REMOVE EXISTING WINDOW, FRAME, AND ALL ASSOCIATED HARDWARE. PREPARE
OPENING FOR NEW WINDOW SYSTEM WITH SOLID SURFACE SILL.
3 REMOVE AND SALVAGE EXISTING ROLLER BLINDS, VERTICAL BLINDS, AND CURTAINS FOR
REINSTALLATION AFTER WINDOW REPLACEMENT OCCURS.
4 REMOVE EXISTING WINDOW, FRAME, AND ALL ASSOCIATED HARDWARE. PREPARE
OPENING FOR NEW WINDOW SYSTEM.
AREA A
ABATEMENT DEMOLITION SCOPE:
1. ALL EXTERIOR WINDOWS AND WINDOWSILLS SHALL BE INSPECTED TO DETERMINE THE EXACT SCOPE OF WORK AND CONDITION IN ORDER FOR THE NEW WINDOWS AND WINDOWSILLS TO BE REPLACED & RESTORED TO A SAFE CONDITION.
2. REMOVE APPROXIMATELY 225 TOTAL SQUARE FEET OF ASBESTOS LADEN MATERIAL FROM THE WINDOWSILLS OF ALL EXISTING WINDOWS USING THE APPROPRIATE REMOVAL METHOD IN FULL COMPLIANCE WITH ALL STATE AND LOCAL CODES.
3. CONTRACTOR SHALL PROVIDE THE NECESSARY PERMITS FOR ABATEMENT AND SHALL COMPLY WITH ALL STATE AND LOCAL CODE
REQUIREMENTS.
4. BLACK BITUMINOUS MASTIC BETWEEN THE WINDOWSILL AND THE MASONRY WALL SHALL BE ABATED BY A CERTIFIED ASBESTOS ABATEMENT
CONTRACTOR.
5. ALL ABATEMENT WORK TO BE PERFORMED BY CERTIFIED ABATEMENT PROFESSIONAL ONLY.
A. HAZARDOUS MATERIALS LISTED / DESCRIBED ARE TO THE BEST KNOWLEDGE OF THE ENGINEER / ARCHITECT.
B. CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER IDENTIFICATION AND DISPOSAL OF THESE ITEMS IN ACCORDANCE WITH OSHA
AND OTHER REQUIREMENTS.
C. IF OTHER SUSPECTED HAZARDOUS MATERIALS ARE UNCOVERED DURING DEMOLITION, CONTRACTOR SHALL HAVE MATERIALS
TESTED AND / OR SHALL HANDLE AS REQUIRED BY OSHA.
6. SEE HAZARDOUS MATERIALS TESTING REPORT IN THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
ASBESTOS CONTAINING MATERIAL:
-BLACK MASTIC: LOCATED BETWEEN THE WINDOWSILL AND THE MASONRY WALL. IT IS REQUIRED THAT THIS MATERIAL BE ABATED BY A CERTIFIED ASBESTOS ABATEMENT CONTRACTOR. THERE IS APPROXIMATELY 225 SQUARE FEET OF WINDOWSILL TO BE REMOVED.
NOTE: REFER TO SAMPLING REPORT - "ASBESTOS SURVEY & LEAD AND CADMIUM CONTAINING PAINT SAMPLE REPORT" - FOR MORE INFORMATION.
ABATEMENT WORK NOT INCLUDED IN CONTRACT. TO BE COMPLETED BY OTHERS PRIOR TO THE START OF WORK.
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T
NO
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R
D
AT
E:
1 2 3 4 5
1 2 3 4 5
C :\U se rs
\ra nd er so n\ D oc um en ts
\B
3-
_B
AS
W in do w R ep la ce m en t_
C
EN
TR
AL
_R
_r an de rs on up ea
.c om
.rv t
9/
/2
:0 0:
A
M
A100.1
DEMOLITION PLAN
- AREA A
B
AR
AG
A
AR
EA
S C
H O
O
LS
W
IN
DO
W
R
EP
LA
CE
ME
NT
0 L
YO
NS
S
TR
EE
T, B
AR
AG
A, M I 4
B1
-0
R M
A
JA R
M A
R M
A
BA
RA
GA
A
RE
A
SC
HO
OL
S
W
IN
DO
W
R
EP
LA
CE
M
EN
T
1/8" = 1'-0"A1 DEMOLITION PLAN - AREA A
NORTH
NO SCALE- KEY PLAN
LA
R
A R
EV
IE
W
/1 1/
R.
O.
'-0
"W x
'-4
"H
R.
O.
'-0
"W x
'-4
"H
R.O. 6'-0"W x 4'-4"H
R.O. 8'-0"W x 4'-4"H
R.
O.
'-0
"W x
'-6
"H
R.O. 7' -4"
W x 6 '-8"
H
1 3
DEMOLITION KEYNOTES -
1 REFER TO A090 - ABATEMENT DEMOLITION PLAN FOR REMOVAL OF ASBESTOS LADEN
WINDOWSILLS AND ADHESIVE.
2 REMOVE EXISTING WINDOW, FRAME, AND ALL ASSOCIATED HARDWARE. PREPARE
OPENING FOR NEW WINDOW SYSTEM WITH SOLID SURFACE SILL.
3 REMOVE AND SALVAGE EXISTING ROLLER BLINDS, VERTICAL BLINDS, AND CURTAINS FOR
REINSTALLATION AFTER WINDOW REPLACEMENT OCCURS.
4 REMOVE EXISTING WINDOW, FRAME, AND ALL ASSOCIATED HARDWARE. PREPARE
OPENING FOR NEW WINDOW SYSTEM.
AREA B
R.O. 10'-0"W x 6'-8"H
ABATEMENT DEMOLITION SCOPE:
1. ALL EXTERIOR WINDOWS AND WINDOWSILLS SHALL BE INSPECTED TO DETERMINE THE EXACT SCOPE OF WORK AND CONDITION IN ORDER FOR THE NEW WINDOWS AND WINDOWSILLS TO BE REPLACED & RESTORED TO A SAFE CONDITION.
2. REMOVE APPROXIMATELY 225 TOTAL SQUARE FEET OF ASBESTOS LADEN MATERIAL FROM THE WINDOWSILLS OF ALL EXISTING WINDOWS USING THE APPROPRIATE REMOVAL METHOD IN FULL COMPLIANCE WITH ALL STATE AND LOCAL CODES.
3. CONTRACTOR SHALL PROVIDE THE NECESSARY PERMITS FOR ABATEMENT AND SHALL COMPLY WITH ALL STATE AND LOCAL CODE
REQUIREMENTS.
4. BLACK BITUMINOUS MASTIC BETWEEN THE WINDOWSILL AND THE MASONRY WALL SHALL BE ABATED BY A CERTIFIED ASBESTOS ABATEMENT
CONTRACTOR.
5. ALL ABATEMENT WORK TO BE PERFORMED BY CERTIFIED ABATEMENT PROFESSIONAL ONLY.
A. HAZARDOUS MATERIALS LISTED / DESCRIBED ARE TO THE BEST KNOWLEDGE OF THE ENGINEER / ARCHITECT.
B. CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER IDENTIFICATION AND DISPOSAL OF THESE ITEMS IN ACCORDANCE WITH OSHA
AND OTHER REQUIREMENTS.
C. IF OTHER SUSPECTED HAZARDOUS MATERIALS ARE UNCOVERED DURING DEMOLITION, CONTRACTOR SHALL HAVE MATERIALS
TESTED AND / OR SHALL HANDLE AS REQUIRED BY OSHA.
6. SEE HAZARDOUS MATERIALS TESTING REPORT IN THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
ASBESTOS CONTAINING MATERIAL:
-BLACK MASTIC: LOCATED BETWEEN THE WINDOWSILL AND THE MASONRY WALL. IT IS REQUIRED THAT THIS MATERIAL BE ABATED BY A CERTIFIED ASBESTOS ABATEMENT CONTRACTOR. THERE IS APPROXIMATELY 225 SQUARE FEET OF WINDOWSILL TO BE REMOVED.
NOTE: REFER TO SAMPLING REPORT - "ASBESTOS SURVEY & LEAD AND CADMIUM CONTAINING PAINT SAMPLE REPORT" - FOR MORE INFORMATION.
ABATEMENT WORK NOT INCLUDED IN CONTRACT. TO BE COMPLETED BY OTHERS PRIOR TO THE START OF WORK.
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T
NO
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R
D
AT
E:
1 2 3 4 5
1 2 3 4 5
C :\U se rs
\ra nd er so n\ D oc um en ts
\B
3-
_B
AS
W in do w R ep la ce m en t_
C
EN
TR
AL
_R
_r an de rs on up ea
.c om
.rv t
9/
/2
:0 0:
A
M
A100.2
DEMOLITION PLAN
- AREA B
B
AR
AG
A
AR
EA
S C
H O
O
LS
W
IN
DO
W
R
EP
LA
CE
ME
NT
0 L
YO
NS
S
TR
EE
T, B
AR
AG
A, M I 4
B1
-0
R M
A
JA R
M A
R M
A
BA
RA
GA
A
RE
A
SC
HO
OL
S
W
IN
DO
W
R
EP
LA
CE
M
EN
T
1/8" = 1'-0"A1 DEMOLITION PLAN - AREA B
NORTH
NO SCALE- KEY PLAN
1" = 10'-0"C5 SECOND FLOOR @ GYM
NORTH
LA
R
A R
EV
IE
W
/1 1/
R.O. 10'-0"W x 6'-8"H
R.O. 6'-0"W x 5'-0"H
R.O. 6'-0"W x 5'-0"H
R.O. 4'-0"W x 6'-0"H
R.O. 10'-0"W x 7'-8"H
R.O. 10'-0"W x 7'-8"H
R.O. 15'-0"W x 6'-0"H
CLASSROOM
LIBRARY
VEST.
LOBBY
CENTRAL OFFICE
SUPT.
BOOK- KEEPING
VAULT
A.D.
GYMNASIUM
STORAGE
STORAGE
STORAGE
314A
A.D.
CORRIDOR
CONC.
JAN.
WOMEN
MEN
CORRIDOR
MULTI-PURPOSE
FAN
STORAGE
STOR.
STOR.
POTTERY
STORAGE
BOYS LOCKERS
GIRLS LOCKERS
STOR.
DEMOLITION KEYNOTES -
1 REFER TO A090 - ABATEMENT DEMOLITION PLAN FOR REMOVAL OF ASBESTOS LADEN
WINDOWSILLS AND ADHESIVE.
2 REMOVE EXISTING WINDOW, FRAME, AND ALL ASSOCIATED HARDWARE. PREPARE
OPENING FOR NEW WINDOW SYSTEM WITH SOLID SURFACE SILL.
3 REMOVE AND SALVAGE EXISTING ROLLER BLINDS, VERTICAL BLINDS, AND CURTAINS FOR
REINSTALLATION AFTER WINDOW REPLACEMENT OCCURS.
4 REMOVE EXISTING WINDOW, FRAME, AND ALL ASSOCIATED HARDWARE. PREPARE
OPENING FOR NEW WINDOW SYSTEM.
AREA C
ABATEMENT DEMOLITION SCOPE:
1. ALL EXTERIOR WINDOWS AND WINDOWSILLS SHALL BE INSPECTED TO DETERMINE THE EXACT SCOPE OF WORK AND CONDITION IN ORDER FOR THE NEW WINDOWS AND WINDOWSILLS TO BE REPLACED & RESTORED TO A SAFE CONDITION.
2. REMOVE APPROXIMATELY 225 TOTAL SQUARE FEET OF ASBESTOS LADEN MATERIAL FROM THE WINDOWSILLS OF ALL EXISTING WINDOWS USING THE APPROPRIATE REMOVAL METHOD IN FULL COMPLIANCE WITH ALL STATE AND LOCAL CODES.
3. CONTRACTOR SHALL PROVIDE THE NECESSARY PERMITS FOR ABATEMENT AND SHALL COMPLY WITH ALL STATE AND LOCAL CODE
REQUIREMENTS.
4. BLACK BITUMINOUS MASTIC BETWEEN THE WINDOWSILL AND THE MASONRY WALL SHALL BE ABATED BY A CERTIFIED ASBESTOS ABATEMENT
CONTRACTOR.
5. ALL ABATEMENT WORK TO BE PERFORMED BY CERTIFIED ABATEMENT PROFESSIONAL ONLY.
A. HAZARDOUS MATERIALS LISTED / DESCRIBED ARE TO THE BEST KNOWLEDGE OF THE ENGINEER / ARCHITECT.
B. CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER IDENTIFICATION AND DISPOSAL OF THESE ITEMS IN ACCORDANCE WITH OSHA
AND OTHER REQUIREMENTS.
C. IF OTHER SUSPECTED HAZARDOUS MATERIALS ARE UNCOVERED DURING DEMOLITION, CONTRACTOR SHALL HAVE MATERIALS
TESTED AND / OR SHALL HANDLE AS REQUIRED BY OSHA.
6. SEE HAZARDOUS MATERIALS TESTING REPORT IN THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
ASBESTOS CONTAINING MATERIAL:
-BLACK MASTIC: LOCATED BETWEEN THE WINDOWSILL AND THE MASONRY WALL. IT IS REQUIRED THAT THIS MATERIAL BE ABATED BY A CERTIFIED ASBESTOS ABATEMENT CONTRACTOR. THERE IS APPROXIMATELY 225 SQUARE FEET OF WINDOWSILL TO BE REMOVED.
NOTE: REFER TO SAMPLING REPORT - "ASBESTOS SURVEY & LEAD AND CADMIUM CONTAINING PAINT SAMPLE REPORT" - FOR MORE INFORMATION.
ABATEMENT WORK NOT INCLUDED IN CONTRACT. TO BE COMPLETED BY OTHERS PRIOR TO THE START OF WORK.
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T
NO
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R
D
AT
E:
1 2 3 4 5
1 2 3 4 5
C :\U se rs
\ra nd er so n\ D oc um en ts
\B
3-
_B
AS
W in do w R ep la ce m en t_
C
EN
TR
AL
_R
_r an de rs on up ea
.c om
.rv t
9/
/2
:0 0:
A
M
A100.3
DEMOLITION PLAN
- AREA C
B
AR
AG
A
AR
EA
S C
H O
O
LS
W
IN
DO
W
R
EP
LA
CE
ME
NT
0 L
YO
NS
S
TR
EE
T, B
AR
AG
A, M I 4
B1
-0
R M
A
JA R
M A
R M
A
BA
RA
GA
A
RE
A
SC
HO
OL
S
W
IN
DO
W
R
EP
LA
CE
M
EN
T
1/8" = 1'-0"A1 DEMOLITION PLAN - AREA C
NORTH
NO SCALE- KEY PLAN
LA
R
A R
EV
IE
W
/1 1/
R.
O.
5'-
0" W x 6'-
0" H
R.
O.
5'-
0" W x 6'-
0" H
R.O. 15'-0"W x 6'-0"H
R.O. 15'-0"W x 6'-0"H
R.O. 6'-0"W x 5'-0"H
R.O. 15'-0"W x 6'-0"H
R.O. 15'-0"W x 5'-11"H
R.O. 15'-0"W x 5'-11"H
R.O. 15'-0"W x 6'-0"H
R.O. 15'-0"W x 6'-0"H
R.O. 15'-0"W x 6'-0"H
R.O. 15'-0"W x 6'-0"H
R.O. 15'-0"W x 6'-0"H
R.O. 15'-0"W x 6'-0"H
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
108A
CLASSROOM
108B
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
OFFICE
OFFICE
208A
CORRIDOR
CORRIDOR
VEST.
112A
GIRLS
BOYS
JAN.
STORAGE
G.E.
OFFICE
T.O.
207A
T.O.
209A
OFFICE
ELEM. OFFICE
DEAN OF STUDENTS
316A
H.S. TITLE-1
K.B.I.C.
TLT.
212A
TLT.
229A
HEALTH
OFFICE
STOR.
208B
1 31 31 31 3 1 3
3 1 3 1 3 1 3 1 3 1 3 1 3 1
AREA D
DEMOLITION KEYNOTES -
1 REFER TO A090 - ABATEMENT DEMOLITION PLAN FOR REMOVAL OF ASBESTOS LADEN
WINDOWSILLS AND ADHESIVE.
2 REMOVE EXISTING WINDOW, FRAME, AND ALL ASSOCIATED HARDWARE. PREPARE
OPENING FOR NEW WINDOW SYSTEM WITH SOLID SURFACE SILL.
3 REMOVE AND SALVAGE EXISTING ROLLER BLINDS, VERTICAL BLINDS, AND CURTAINS FOR
REINSTALLATION AFTER WINDOW REPLACEMENT OCCURS.
4 REMOVE EXISTING WINDOW, FRAME, AND ALL ASSOCIATED HARDWARE. PREPARE
OPENING FOR NEW WINDOW SYSTEM.
ABATEMENT DEMOLITION SCOPE:
1. ALL EXTERIOR WINDOWS AND WINDOWSILLS SHALL BE INSPECTED TO DETERMINE THE EXACT SCOPE OF WORK AND CONDITION IN ORDER FOR THE NEW WINDOWS AND WINDOWSILLS TO BE REPLACED & RESTORED TO A SAFE CONDITION.
2. REMOVE APPROXIMATELY 225 TOTAL SQUARE FEET OF ASBESTOS LADEN MATERIAL FROM THE WINDOWSILLS OF ALL EXISTING WINDOWS USING THE APPROPRIATE REMOVAL METHOD IN FULL COMPLIANCE WITH ALL STATE AND LOCAL CODES.
3. CONTRACTOR SHALL PROVIDE THE NECESSARY PERMITS FOR ABATEMENT AND SHALL COMPLY WITH ALL STATE AND LOCAL CODE
REQUIREMENTS.
4. BLACK BITUMINOUS MASTIC BETWEEN THE WINDOWSILL AND THE MASONRY WALL SHALL BE ABATED BY A CERTIFIED ASBESTOS ABATEMENT
CONTRACTOR.
5. ALL ABATEMENT WORK TO BE PERFORMED BY CERTIFIED ABATEMENT PROFESSIONAL ONLY.
A. HAZARDOUS MATERIALS LISTED / DESCRIBED ARE TO THE BEST KNOWLEDGE OF THE ENGINEER / ARCHITECT.
B. CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER IDENTIFICATION AND DISPOSAL OF THESE ITEMS IN ACCORDANCE WITH OSHA
AND OTHER REQUIREMENTS.
C. IF OTHER SUSPECTED HAZARDOUS MATERIALS ARE UNCOVERED DURING DEMOLITION, CONTRACTOR SHALL HAVE MATERIALS
TESTED AND / OR SHALL HANDLE AS REQUIRED BY OSHA.
6. SEE HAZARDOUS MATERIALS TESTING REPORT IN THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
ASBESTOS CONTAINING MATERIAL:
-BLACK MASTIC: LOCATED BETWEEN THE WINDOWSILL AND THE MASONRY WALL. IT IS REQUIRED THAT THIS MATERIAL BE ABATED BY A CERTIFIED ASBESTOS ABATEMENT CONTRACTOR. THERE IS APPROXIMATELY 225 SQUARE FEET OF WINDOWSILL TO BE REMOVED.
NOTE: REFER TO SAMPLING REPORT - "ASBESTOS SURVEY & LEAD AND CADMIUM CONTAINING PAINT SAMPLE REPORT" - FOR MORE INFORMATION.
ABATEMENT WORK NOT INCLUDED IN CONTRACT. TO BE COMPLETED BY OTHERS PRIOR TO THE START OF WORK.
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T
NO
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R
D
AT
E:
1 2 3 4 5
1 2 3 4 5
C :\U se rs
\ra nd er so n\ D oc um en ts
\B
3-
_B
AS
W in do w R ep la ce m en t_
C
EN
TR
AL
_R
_r an de rs on up ea
.c om
.rv t
9/
/2
:0 0:
A
M
A100.4
DEMOLITION PLAN
- AREA D
B
AR
AG
A
AR
EA
S C
H O
O
LS
W
IN
DO
W
R
EP
LA
CE
ME
NT
0 L
YO
NS
S
TR
EE
T, B
AR
AG
A, M I 4
B1
-0
R M
A
JA R
M A
R M
A
BA
RA
GA
A
RE
A
SC
HO
OL
S
W
IN
DO
W
R
EP
LA
CE
M
EN
T
1/8" = 1'-0"A1 DEMOLITION PLAN - AREA D
NORTH
NO SCALE- KEY PLAN
LA
R
A R
EV
IE
W
/1 1/
R.O. 6'-0"W x 4'-0"H
1 4
R.
O.
'-0
"W x
4'- 0"
H
R.
O.
'-0
"W x
'-0
"H
R.O. 6'-0"W x 4'-0"H
1 4
R.O. 6'-0"W x 4'-0"H
1 4
R.O. 6'-0"W x 4'-0"H
1 4
R.O. 6'-0"W x 4'-0"H
R.O. 6'-0"W x 4'-0"H
1 4
R.O. 6'-0"W x 4'-0"H
1 4
R.O. 6'-0"W x 4'-0"H
1 4
R.O. 6'-0"W x 4'-0"H
1 4
R.O. 6'-0"W x 4'-0"H
VOCATIONAL
EDUCATION
R.O. 6'-0"W x 4'-0"H
1 43
3 1 43 1 43
AREA E
ABATEMENT DEMOLITION SCOPE:
1. ALL EXTERIOR WINDOWS AND WINDOWSILLS SHALL BE INSPECTED TO DETERMINE THE EXACT SCOPE OF WORK AND CONDITION IN ORDER FOR THE NEW WINDOWS AND WINDOWSILLS TO BE REPLACED & RESTORED TO A SAFE CONDITION.
2. REMOVE APPROXIMATELY 225 TOTAL SQUARE FEET OF ASBESTOS LADEN MATERIAL FROM THE WINDOWSILLS OF ALL EXISTING WINDOWS USING THE APPROPRIATE REMOVAL METHOD IN FULL COMPLIANCE WITH ALL STATE AND LOCAL CODES.
3. CONTRACTOR SHALL PROVIDE THE NECESSARY PERMITS FOR ABATEMENT AND SHALL COMPLY WITH ALL STATE AND LOCAL CODE
REQUIREMENTS.
4. BLACK BITUMINOUS MASTIC BETWEEN THE WINDOWSILL AND THE MASONRY WALL SHALL BE ABATED BY A CERTIFIED ASBESTOS ABATEMENT
CONTRACTOR.
5. ALL ABATEMENT WORK TO BE PERFORMED BY CERTIFIED ABATEMENT PROFESSIONAL ONLY.
A. HAZARDOUS MATERIALS LISTED / DESCRIBED ARE TO THE BEST KNOWLEDGE OF THE ENGINEER / ARCHITECT.
B. CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER IDENTIFICATION AND DISPOSAL OF THESE ITEMS IN ACCORDANCE WITH OSHA
AND OTHER REQUIREMENTS.
C. IF OTHER SUSPECTED HAZARDOUS MATERIALS ARE UNCOVERED DURING DEMOLITION, CONTRACTOR SHALL HAVE MATERIALS
TESTED AND / OR SHALL HANDLE AS REQUIRED BY OSHA.
6. SEE HAZARDOUS MATERIALS TESTING REPORT IN THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
ASBESTOS CONTAINING MATERIAL:
-BLACK MASTIC: LOCATED BETWEEN THE WINDOWSILL AND THE MASONRY WALL. IT IS REQUIRED THAT THIS MATERIAL BE ABATED BY A CERTIFIED ASBESTOS ABATEMENT CONTRACTOR. THERE IS APPROXIMATELY 225 SQUARE FEET OF WINDOWSILL TO BE REMOVED.
NOTE: REFER TO SAMPLING REPORT - "ASBESTOS SURVEY & LEAD AND CADMIUM CONTAINING PAINT SAMPLE REPORT" - FOR MORE INFORMATION.
ABATEMENT WORK NOT INCLUDED IN CONTRACT. TO BE COMPLETED BY OTHERS PRIOR TO THE START OF WORK.
DEMOLITION KEYNOTES -
1 REFER TO A090 - ABATEMENT DEMOLITION PLAN FOR REMOVAL OF ASBESTOS LADEN
WINDOWSILLS AND ADHESIVE.
2 REMOVE EXISTING WINDOW, FRAME, AND ALL ASSOCIATED HARDWARE. PREPARE
OPENING FOR NEW WINDOW SYSTEM WITH SOLID SURFACE SILL.
3 REMOVE AND SALVAGE EXISTING ROLLER BLINDS, VERTICAL BLINDS, AND CURTAINS FOR
REINSTALLATION AFTER WINDOW REPLACEMENT OCCURS.
4 REMOVE EXISTING WINDOW, FRAME, AND ALL ASSOCIATED HARDWARE. PREPARE
OPENING FOR NEW WINDOW SYSTEM.
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T
NO
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R
D
AT
E:
1 2 3 4 5
1 2 3 4 5
C :\U se rs
\ra nd er so n\ D oc um en ts
\B
3-
_B
AS
W in do w R ep la ce m en t_
C
EN
TR
AL
_R
_r an de rs on up ea
.c om
.rv t
9/
/2
:0 0:
A
M
A100.5
DEMOLITION PLAN
- AREA E
B
AR
AG
A
AR
EA
S C
H O
O
LS
W
IN
DO
W
R
EP
LA
CE
ME
NT
0 L
YO
NS
S
TR
EE
T, B
AR
AG
A, M I 4
B1
-0
R M
A
JA R
M A
R M
A
BA
RA
GA
A
RE
A
SC
HO
OL
S
W
IN
DO
W
R
EP
LA
CE
M
EN
T
LA
R A
R
EV
IE
W
/1
1/
1/8" = 1'-0"A1 DEMOLITION PLAN - AREA E
NO SCALE2 KEY PLAN
NORTH
A101.1 A1
A101.2 A1
A101.3 A1
A101.4 A1
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
108A
CLASSROOM
108B
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
COMMONS
CLASSROOM
CLASSROOM
CLASSROOM
213CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
MEETING RM.
CLASSROOM
VEST.
LOBBY
CENTRAL
OFFICE
SUPT.
BOOK-
KEEPING
VAULT
A.D.
GYMNASIUM
STORAGE
STORAGE
LIBRARY
STORAGE
314A
K.B.I.C.
OFFICE
OFFICE
208A
A.D.
CORRIDOR
C O
R R
ID
O
R
C O
R R
ID
O
R
CONC.
012JAN.
WOMEN
014MEN
CORRIDOR
MULTI-PURPOSE
FAN
STORAGE
STOR.
STOR.
POTTERY
STORAGE
VEST.
112A
GIRLS
114 BOYS
JAN.
STORAGE
G.E.
OFFICE
T.O.
207A
T.O.
209A
OFFICE
ELEM. OFFICE
316A
DEAN OF
STUDENTS
H.S. TITLE-1
K.B.I.C.
TLT.
TLT.
HEALTH
OFFICE
BOYS
LOCKERS
GIRLS
LOCKERS
CORRIDOR
VEST.
225A
STOR.
STOR.
217A
CORRIDOR
H.S.
OFFICE
OFFICE
OFFICE
304 LOUNGE
TLT.
TLT.
BOILER ROOM
STOR.
WOMEN
MEN
JAN.
CORRIDOR
CORRIDOR
CORRIDOR
STOR.
ELEC.
KITCHEN
DRY STOR.
320A
COOLER
320B
STOR.
FREEZER
320C
TLT.
RECEIVING
STOR.
210A
STOR.
210B
STOR.
210C
STOR.
210D
VEST.
DRYING
333332
BOYS
LOCKERS
OFFICE
GIRLS
LOCKERS
OFFICE
STOR.
STOR.
208B
STOR.
008A
STOR.
008B
JAN.
STOR.
206A
ABOVE
AREA A
AREA B
AREA C
AREA D
A101.5
A3 AREA E
AREA A
AREA B
AREA CAREA D
AREA E
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T
NO
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R
D
AT
E:
1 2 3 4 5
1 2 3 4 5
C :\U se rs
\ra nd er so n\ D oc um en ts
\B
3-
_B
AS
W in do w R ep la ce m en t_
C
EN
TR
AL
_R
_r an de rs on up ea
.c om
.rv t
9/
/2
:0 0:
A
M
A101
OVERALL FLOOR
PLAN
B
AR
AG
A
AR
EA
S C
H O
O
LS
W
IN
DO
W
R
EP
LA
CE
ME
NT
0 L
YO
NS
S
TR
EE
T, B
AR
AG
A, M I 4
B1
-0
R M
A
JA R
M A
R M
A
BA
RA
GA
A
RE
A
SC
HO
OL
S
W
IN
DO
W
R
EP
LA
CE
M
EN
T
NORTH
1/16" = 1'-0"A1 OVERALL FLOOR PLAN
NO SCALE- KEY PLAN
LA
R
A R
EV
IE
W
/1 1/
COMMONS
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CORRIDOR
VEST.
225A
STOR.
STOR.
217A
CORRIDOR
STOR.
WOMEN
MEN
JAN.
12' - 0"12' - 0"12' - 0"12' - 0"12' - 0" 12' - 0"
B B B B B B
B B B B B
12' - 0"12' - 0"12' - 0"12' - 0"12' - 0"
0"
A
1 1 1 1 1
1 1 1 1
2 2 2 2 2 2
2 2 2 2 2
6'
- 0
G
G 6'
- 0
"1
A201
D3
PROPOSED KEYNOTES -
1 AFTER WINDOW INSTALLATION, REINSTALL EXISTING ROLLER BLINDS, VERTICAL
BLINDS, OR CURTAINS AT EXISTING WINDOW OPENING.
BID ALT #1: REMOVE AND DISPOSE OF EXISTING ROLLER BLINDS, VERTICAL BLINDS,
AND CURTAINS. PROVIDE NEW MANUAL ROLLER SHADES w/ ROOM DARKENING FABRIC
TO PROVIDE MAXIMUM PRIVACY. PROVIDE A SQUARE FASCIA TOP TREATMENT WITH A
MANUAL PULL CHAIN. SHADE & FASCIA COLOR T.B.D. BY OWNER. CONTRACTOR SHALL
FIELD VERIFY WINDOW OPENINGS PRIOR TO ORDERING AND INSTALLATION.
BID ALT #1:
AREA A
GENERAL NOTES
1. WINDOW DESIGNATION: SEE FLOOR PLANS FOR LOCATION OF WINDOWS.
2. SIZE: SIZE IS GIVEN AS OVERALL WIDTH x HEIGHT ROUGH OPENING.
3. PROVIDE NEW 1/2" SOLID SURFACE WINDOWSILL / STOOL, ON 1/2" PT PLYWOOD SUBSTRATE.
COLOR TO BE DETERMINED BY OWNER.
4. WINDOWS MAY BE BUILT FROM A CURTAIN WALL FRAMING SYSTEM, PROVIDED THAT ALL REQUIRED
FUNCTIONALITY CAN BE THE SAME AS WHAT IS SPECIFIED.
5. EXTERIOR COLOR SHALL MATCH EXISTING ALUMINUM COLOR.
6. INTERIOR COLOR SHALL MATCH EXISTING ALUMINUM COLOR.
7. CONTRACTOR SHALL FIELD MEASURE ALL WINDOWS PRIOR TO SUBMITTING A PROPOSAL.
8. CONTRACTOR SHALL INSPECT WINDOW ROUGH OPENINGS PRIOR TO INSTALLING NEW WINDOWS.
ROUGH OPENING SHOULD BE FREE FROM DECAY. CONTACT ARCHITECT IMMEDIATELY IF DECAYED
MATERIALS ARE DISCOVERED.
9. WINDOW SUPPLIER SHALL PROVIDE ALL MULLION COVERS AND INSTALLATION ACCESSORIES.
10. WINDOWS SHALL BE INSTALLED PLUMB, SQUARE, LEVEL, AND TRUE.
11. CONTRACTOR SHALL STORE NEW WINDOWS IN A DRY, SECURE AREA, IN A LOCATION
COORDINATED WITH OWNER.
12. FOAM INSULATE ALL VOIDS AT SHIM SPACES AND PERIMETER OF FRAME.
13. CONTRACTOR SHALL CLEAN ALL WINDOWS AFTER INSTALLATION.
ALUMINUM WINDOW SCHEDULE
TYPE
DETAILS
HEAD JAMB SILL REMARKS
A
B
C
D
E
F
G
D2 / A401 D3 / A401 C2 / A401 CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
H CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
J CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
K CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS., TINTED GLASS @ GYM WINDOWS.
L CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
WIDTH
15' - 0"
12' - 0"
10' - 0"
8' - 0"
7' - 4"
6' - 0"
6' - 0"
6' - 0"
4' - 0"
10' - 0"
6' - 0"
HEIGHT
6' - 0"
5' - 0"
6' - 8"
6' - 8"
6' - 8"
6' - 0"
4' - 4"
6' - 8"
4' - 4"
6' - 8"
5' - 0"
M CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.4' - 0" 5' - 0"
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
MASONRY OPENING
N CONTRACTOR TO VERIFY SIZE OF EXISTING R.O. PRIOR TO SHOP DWGS.6' - 0" 4' - 0" - - -
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T
NO
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R
D
AT
E:
1 2 3 4 5
1 2 3 4 5
C :\U se rs
\ra nd er so n\ D oc um en ts
\B
3-
_B
AS
W in do w R ep la ce m en t_
C
EN
TR
AL
_R
_r an de rs on up ea
.c om
.rv t
9/
/2
:0 0:
A
M
A101.1
PROPOSED
FLOOR PLAN -
AREA A
B
AR
AG
A
AR
EA
S C
H O
O
LS
W
IN
DO
W
R
EP
LA
CE
ME
NT
0 L
YO
NS
S
TR
EE
T, B
AR
AG
A, M I 4
B1
-0
R M
A
JA R
M A
R M
A
BA
RA
GA
A
RE
A
SC
HO
OL
S
W
IN
DO
W
R
EP
LA
CE
M
EN
T
1/8" = 1'-0"A1 PROPOSED FLOOR PLAN - AREA A
NORTH
NO SCALE- KEY PLAN
LA
R
A R
EV
IE
W
/1 1/
UPUP
COMMONS
MEETING RM.
CLASSROOM
K.B.I.C.
OFFICE
208A
CORRIDOR
H.S. OFFICE
OFFICE
OFFICE
LOUNGE
TLT.
TLT.
BOILER ROOM
JAN.
CORRIDOR
CORRIDOR
CORRIDOR
STOR.
ELEC.
KITCHEN
DRY STOR.
320ACOOLER
320B
STOR.
FREEZER
320C
TLT.
RECEIVING
STOR.
210A
STOR.
210B
STOR.
210C
STOR.
210D
VEST.
DRYING
BOYS LOCKERS
OFFICE
GIRLS LOCKERS
OFFICE
STOR.
STOR.
208B
STOR.
008A
STOR.
008B
JAN.
STOR.
206A
6'
- 0
G
G 6'
- 0
6' - 0"
8' - 0"
4'
- 0
7' - 4"
D
H
E
J
AREA B
DN
10' - 0"
K
PROPOSED KEYNOTES -
1 AFTER WINDOW INSTALLATION, REINSTALL EXISTING ROLLER BLINDS, VERTICAL
BLINDS, OR CURTAINS AT EXISTING WINDOW OPENING.
BID ALT #1: REMOVE AND DISPOSE OF EXISTING ROLLER BLINDS, VERTICAL BLINDS,
AND CURTAINS. PROVIDE NEW MANUAL ROLLER SHADES w/ ROOM DARKENING FABRIC
TO PROVIDE MAXIMUM PRIVACY. PROVIDE A SQUARE FASCIA TOP TREATMENT WITH A
MANUAL PULL CHAIN. SHADE & FASCIA COLOR T.B.D. BY OWNER. CONTRACTOR SHALL
FIELD VERIFY WINDOW OPENINGS PRIOR TO ORDERING AND INSTALLATION.
BID ALT #1:
GENERAL NOTES
1. WINDOW DESIGNATION: SEE FLOOR PLANS FOR LOCATION OF WINDOWS.
2. SIZE: SIZE IS GIVEN AS OVERALL WIDTH x HEIGHT ROUGH OPENING.
3. PROVIDE NEW 1/2" SOLID SURFACE WINDOWSILL / STOOL, ON 1/2" PT PLYWOOD SUBSTRATE.
COLOR TO BE DETERMINED BY OWNER.
4. WINDOWS MAY BE BUILT FROM A CURTAIN WALL FRAMING SYSTEM, PROVIDED THAT ALL REQUIRED
FUNCTIONALITY CAN BE THE SAME AS WHAT IS SPECIFIED.
5. EXTERIOR COLOR SHALL MATCH EXISTING ALUMINUM COLOR.
6. INTERIOR COLOR SHALL MATCH EXISTING ALUMINUM COLOR.
7. CONTRACTOR SHALL FIELD MEASURE ALL WINDOWS PRIOR TO SUBMITTING A PROPOSAL.
8. CONTRACTOR SHALL INSPECT WINDOW ROUGH OPENINGS PRIOR TO INSTALLING NEW WINDOWS.
ROUGH OPENING SHOULD BE FREE FROM DECAY. CONTACT ARCHITECT IMMEDIATELY IF DECAYED
MATERIALS ARE DISCOVERED.
9. WINDOW SUPPLIER SHALL PROVIDE ALL MULLION COVERS AND INSTALLATION ACCESSORIES.
10. WINDOWS SHALL BE INSTALLED PLUMB, SQUARE, LEVEL, AND TRUE.
11. CONTRACTOR SHALL STORE NEW WINDOWS IN A DRY, SECURE AREA, IN A LOCATION
COORDINATED WITH OWNER.
12. FOAM INSULATE ALL VOIDS AT SHIM SPACES AND PERIMETER OF FRAME.
13. CONTRACTOR SHALL CLEAN ALL WINDOWS AFTER INSTALLATION.
ALUMINUM WINDOW SCHEDULE
TYPE
DETAILS
HEAD JAMB SILL REMARKS
A
B
C
D
E
F
G
D2 / A401 D3 / A401 C2 / A401 CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
H CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
J CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
K CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS., TINTED GLASS @ GYM WINDOWS.
L CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
WIDTH
15' - 0"
12' - 0"
10' - 0"
8' - 0"
7' - 4"
6' - 0"
6' - 0"
6' - 0"
4' - 0"
10' - 0"
6' - 0"
HEIGHT
6' - 0"
5' - 0"
6' - 8"
6' - 8"
6' - 8"
6' - 0"
4' - 4"
6' - 8"
4' - 4"
6' - 8"
5' - 0"
M CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.4' - 0" 5' - 0"
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
MASONRY OPENING
N CONTRACTOR TO VERIFY SIZE OF EXISTING R.O. PRIOR TO SHOP DWGS.6' - 0" 4' - 0" - - -
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T
NO
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R
D
AT
E:
1 2 3 4 5
1 2 3 4 5
C :\U se rs
\ra nd er so n\ D oc um en ts
\B
3-
_B
AS
W in do w R ep la ce m en t_
C
EN
TR
AL
_R
_r an de rs on up ea
.c om
.rv t
9/
/2
:0 0:
A
M
A101.2
PROPOSED
FLOOR PLAN -
AREA B
B
AR
AG
A
AR
EA
S C
H O
O
LS
W
IN
DO
W
R
EP
LA
CE
ME
NT
0 L
YO
NS
S
TR
EE
T, B
AR
AG
A, M I 4
B1
-0
R M
A
JA R
M A
R M
A
BA
RA
GA
A
RE
A
SC
HO
OL
S
W
IN
DO
W
R
EP
LA
CE
M
EN
T
1/8" = 1'-0"A1 PROPOSED FLOOR PLAN - AREA B
NORTH
NO SCALE- KEY PLAN
NORTH
1" = 10'-0"C5 SECOND FLOOR @ GYM
LA
R
A R
EV
IE
W
/1 1/
CLASSROOM
LIBRARY
VEST.
LOBBY
CENTRAL OFFICE
SUPT.
BOOK- KEEPING
VAULT
A.D.
GYMNASIUM
STORAGE
STORAGE
STORAGE
314A
A.D.
CONC.
JAN.
WOMEN
MEN
CORRIDOR
MULTI-PURPOSE
FAN
STORAGE
STOR.
STOR.
POTTERY
STORAGE
BOYS LOCKERS
GIRLS LOCKERS
STOR.
10'
- 0
6' - 0"
6' - 0"
4' - 0"
10'
- 0
"10' - 0"
15' - 0"
CORRIDOR
A
C C
K
L
L
M
2 2
AREA C
PROPOSED KEYNOTES -
1 AFTER WINDOW INSTALLATION, REINSTALL EXISTING ROLLER BLINDS, VERTICAL
BLINDS, OR CURTAINS AT EXISTING WINDOW OPENING.
BID ALT #1: REMOVE AND DISPOSE OF EXISTING ROLLER BLINDS, VERTICAL BLINDS,
AND CURTAINS. PROVIDE NEW MANUAL ROLLER SHADES w/ ROOM DARKENING FABRIC
TO PROVIDE MAXIMUM PRIVACY. PROVIDE A SQUARE FASCIA TOP TREATMENT WITH A
MANUAL PULL CHAIN. SHADE & FASCIA COLOR T.B.D. BY OWNER. CONTRACTOR SHALL
FIELD VERIFY WINDOW OPENINGS PRIOR TO ORDERING AND INSTALLATION.
BID ALT #1:
GENERAL NOTES
1. WINDOW DESIGNATION: SEE FLOOR PLANS FOR LOCATION OF WINDOWS.
2. SIZE: SIZE IS GIVEN AS OVERALL WIDTH x HEIGHT ROUGH OPENING.
3. PROVIDE NEW 1/2" SOLID SURFACE WINDOWSILL / STOOL, ON 1/2" PT PLYWOOD SUBSTRATE.
COLOR TO BE DETERMINED BY OWNER.
4. WINDOWS MAY BE BUILT FROM A CURTAIN WALL FRAMING SYSTEM, PROVIDED THAT ALL REQUIRED
FUNCTIONALITY CAN BE THE SAME AS WHAT IS SPECIFIED.
5. EXTERIOR COLOR SHALL MATCH EXISTING ALUMINUM COLOR.
6. INTERIOR COLOR SHALL MATCH EXISTING ALUMINUM COLOR.
7. CONTRACTOR SHALL FIELD MEASURE ALL WINDOWS PRIOR TO SUBMITTING A PROPOSAL.
8. CONTRACTOR SHALL INSPECT WINDOW ROUGH OPENINGS PRIOR TO INSTALLING NEW WINDOWS.
ROUGH OPENING SHOULD BE FREE FROM DECAY. CONTACT ARCHITECT IMMEDIATELY IF DECAYED
MATERIALS ARE DISCOVERED.
9. WINDOW SUPPLIER SHALL PROVIDE ALL MULLION COVERS AND INSTALLATION ACCESSORIES.
10. WINDOWS SHALL BE INSTALLED PLUMB, SQUARE, LEVEL, AND TRUE.
11. CONTRACTOR SHALL STORE NEW WINDOWS IN A DRY, SECURE AREA, IN A LOCATION
COORDINATED WITH OWNER.
12. FOAM INSULATE ALL VOIDS AT SHIM SPACES AND PERIMETER OF FRAME.
13. CONTRACTOR SHALL CLEAN ALL WINDOWS AFTER INSTALLATION.
ALUMINUM WINDOW SCHEDULE
TYPE
DETAILS
HEAD JAMB SILL REMARKS
A
B
C
D
E
F
G
D2 / A401 D3 / A401 C2 / A401 CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
H CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
J CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
K CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS., TINTED GLASS @ GYM WINDOWS.
L CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
WIDTH
15' - 0"
12' - 0"
10' - 0"
8' - 0"
7' - 4"
6' - 0"
6' - 0"
6' - 0"
4' - 0"
10' - 0"
6' - 0"
HEIGHT
6' - 0"
5' - 0"
6' - 8"
6' - 8"
6' - 8"
6' - 0"
4' - 4"
6' - 8"
4' - 4"
6' - 8"
5' - 0"
M CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.4' - 0" 5' - 0"
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
MASONRY OPENING
N CONTRACTOR TO VERIFY SIZE OF EXISTING R.O. PRIOR TO SHOP DWGS.6' - 0" 4' - 0" - - -
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T
NO
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R
D
AT
E:
1 2 3 4 5
1 2 3 4 5
C :\U se rs
\ra nd er so n\ D oc um en ts
\B
3-
_B
AS
W in do w R ep la ce m en t_
C
EN
TR
AL
_R
_r an de rs on up ea
.c om
.rv t
9/
/2
:0 0:
A
M
A101.3
PROPOSED
FLOOR PLAN -
AREA C
B
AR
AG
A
AR
EA
S C
H O
O
LS
W
IN
DO
W
R
EP
LA
CE
ME
NT
0 L
YO
NS
S
TR
EE
T, B
AR
AG
A, M I 4
B1
-0
R M
A
JA R
M A
R M
A
BA
RA
GA
A
RE
A
SC
HO
OL
S
W
IN
DO
W
R
EP
LA
CE
M
EN
T
1/8" = 1'-0"A1 PROPOSED FLOOR PLAN - AREA C
NORTH
NO SCALE- KEY PLAN
LA
R
A R
EV
IE
W
/1 1/
15' - 0"15' - 0"15' - 0"15' - 0"15' - 0"15' - 0"15' - 0"
15' - 0" 15' - 0" 15' - 0" 15' - 0"6' - 0"
0"
0"
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
108A
CLASSROOM
108B
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
OFFICE
OFFICE
208A
CORRIDOR
CORRIDOR
VEST.
112A
GIRLS
BOYS
JAN.
STORAGE
G.E.
OFFICE
T.O.
207A
T.O.
209A
OFFICE
ELEM. OFFICE
DEAN OF STUDENTS
316A
H.S. TITLE-1
K.B.I.C.
TLT.
212A
TLT.
229A
HEALTH
OFFICE
STOR.
208B
AAAAAAA
A A A A
A
A
F
1 1 11 1
22222
2 1 2 1 2 1 2 1 2 1 2 1 2
AREA D
PROPOSED KEYNOTES -
1 AFTER WINDOW INSTALLATION, REINSTALL EXISTING ROLLER BLINDS, VERTICAL
BLINDS, OR CURTAINS AT EXISTING WINDOW OPENING.
BID ALT #1: REMOVE AND DISPOSE OF EXISTING ROLLER BLINDS, VERTICAL BLINDS,
AND CURTAINS. PROVIDE NEW MANUAL ROLLER SHADES w/ ROOM DARKENING FABRIC
TO PROVIDE MAXIMUM PRIVACY. PROVIDE A SQUARE FASCIA TOP TREATMENT WITH A
MANUAL PULL CHAIN. SHADE & FASCIA COLOR T.B.D. BY OWNER. CONTRACTOR SHALL
FIELD VERIFY WINDOW OPENINGS PRIOR TO ORDERING AND INSTALLATION.
BID ALT #1:
GENERAL NOTES
1. WINDOW DESIGNATION: SEE FLOOR PLANS FOR LOCATION OF WINDOWS.
2. SIZE: SIZE IS GIVEN AS OVERALL WIDTH x HEIGHT ROUGH OPENING.
3. PROVIDE NEW 1/2" SOLID SURFACE WINDOWSILL / STOOL, ON 1/2" PT PLYWOOD SUBSTRATE.
COLOR TO BE DETERMINED BY OWNER.
4. WINDOWS MAY BE BUILT FROM A CURTAIN WALL FRAMING SYSTEM, PROVIDED THAT ALL REQUIRED
FUNCTIONALITY CAN BE THE SAME AS WHAT IS SPECIFIED.
5. EXTERIOR COLOR SHALL MATCH EXISTING ALUMINUM COLOR.
6. INTERIOR COLOR SHALL MATCH EXISTING ALUMINUM COLOR.
7. CONTRACTOR SHALL FIELD MEASURE ALL WINDOWS PRIOR TO SUBMITTING A PROPOSAL.
8. CONTRACTOR SHALL INSPECT WINDOW ROUGH OPENINGS PRIOR TO INSTALLING NEW WINDOWS.
ROUGH OPENING SHOULD BE FREE FROM DECAY. CONTACT ARCHITECT IMMEDIATELY IF DECAYED
MATERIALS ARE DISCOVERED.
9. WINDOW SUPPLIER SHALL PROVIDE ALL MULLION COVERS AND INSTALLATION ACCESSORIES.
10. WINDOWS SHALL BE INSTALLED PLUMB, SQUARE, LEVEL, AND TRUE.
11. CONTRACTOR SHALL STORE NEW WINDOWS IN A DRY, SECURE AREA, IN A LOCATION
COORDINATED WITH OWNER.
12. FOAM INSULATE ALL VOIDS AT SHIM SPACES AND PERIMETER OF FRAME.
13. CONTRACTOR SHALL CLEAN ALL WINDOWS AFTER INSTALLATION.
ALUMINUM WINDOW SCHEDULE
TYPE
DETAILS
HEAD JAMB SILL REMARKS
A
B
C
D
E
F
G
D2 / A401 D3 / A401 C2 / A401 CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
H CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
J CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
K CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS., TINTED GLASS @ GYM WINDOWS.
L CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
WIDTH
15' - 0"
12' - 0"
10' - 0"
8' - 0"
7' - 4"
6' - 0"
6' - 0"
6' - 0"
4' - 0"
10' - 0"
6' - 0"
HEIGHT
6' - 0"
5' - 0"
6' - 8"
6' - 8"
6' - 8"
6' - 0"
4' - 4"
6' - 8"
4' - 4"
6' - 8"
5' - 0"
M CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.4' - 0" 5' - 0"
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
MASONRY OPENING
N CONTRACTOR TO VERIFY SIZE OF EXISTING R.O. PRIOR TO SHOP DWGS.6' - 0" 4' - 0" - - -
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T
NO
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R
D
AT
E:
1 2 3 4 5
1 2 3 4 5
C :\U se rs
\ra nd er so n\ D oc um en ts
\B
3-
_B
AS
W in do w R ep la ce m en t_
C
EN
TR
AL
_R
_r an de rs on up ea
.c om
.rv t
9/
/2
:0 0:
A
M
A101.4
PROPOSED
FLOOR PLAN -
AREA D
B
AR
AG
A
AR
EA
S C
H O
O
LS
W
IN
DO
W
R
EP
LA
CE
ME
NT
0 L
YO
NS
S
TR
EE
T, B
AR
AG
A, M I 4
B1
-0
R M
A
JA R
M A
R M
A
BA
RA
GA
A
RE
A
SC
HO
OL
S
W
IN
DO
W
R
EP
LA
CE
M
EN
T
1/8" = 1'-0"A1 PROPOSED FLOOR PLAN - AREA D
NORTH
NO SCALE- KEY PLAN
LA
R
A R
EV
IE
W
/1 1/
N N N N N N N
NN
N N
N
1 1 1
N
6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0"
6'
- 0
6' - 0"6' - 0"6' - 0"
6'
- 0
A201
D1
A201D2
A201
D3
A201 D4
ABATEMENT DEMOLITION SCOPE:
1. ALL EXTERIOR WINDOWS AND WINDOWSILLS SHALL BE INSPECTED TO DETERMINE THE EXACT SCOPE OF WORK AND CONDITION IN ORDER FOR THE NEW WINDOWS AND WINDOWSILLS TO BE REPLACED & RESTORED TO A SAFE CONDITION.
2. REMOVE APPROXIMATELY 225 TOTAL SQUARE FEET OF ASBESTOS LADEN MATERIAL FROM THE WINDOWSILLS OF ALL EXISTING WINDOWS USING THE APPROPRIATE REMOVAL METHOD IN FULL COMPLIANCE WITH ALL STATE AND LOCAL CODES.
3. CONTRACTOR SHALL PROVIDE THE NECESSARY PERMITS FOR ABATEMENT AND SHALL COMPLY WITH ALL STATE AND LOCAL CODE
REQUIREMENTS.
4. BLACK BITUMINOUS MASTIC BETWEEN THE WINDOWSILL AND THE MASONRY WALL SHALL BE ABATED BY A CERTIFIED ASBESTOS ABATEMENT
CONTRACTOR.
5. ALL ABATEMENT WORK TO BE PERFORMED BY CERTIFIED ABATEMENT PROFESSIONAL ONLY.
A. HAZARDOUS MATERIALS LISTED / DESCRIBED ARE TO THE BEST KNOWLEDGE OF THE ENGINEER / ARCHITECT.
B. CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER IDENTIFICATION AND DISPOSAL OF THESE ITEMS IN ACCORDANCE WITH OSHA
AND OTHER REQUIREMENTS.
C. IF OTHER SUSPECTED HAZARDOUS MATERIALS ARE UNCOVERED DURING DEMOLITION, CONTRACTOR SHALL HAVE MATERIALS
TESTED AND / OR SHALL HANDLE AS REQUIRED BY OSHA.
6. SEE HAZARDOUS MATERIALS TESTING REPORT IN THE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
ASBESTOS CONTAINING MATERIAL:
-BLACK MASTIC: LOCATED BETWEEN THE WINDOWSILL AND THE MASONRY WALL. IT IS REQUIRED THAT THIS MATERIAL BE ABATED BY A CERTIFIED ASBESTOS ABATEMENT CONTRACTOR. THERE IS APPROXIMATELY 225 SQUARE FEET OF WINDOWSILL TO BE REMOVED.
NOTE: REFER TO SAMPLING REPORT - "ASBESTOS SURVEY & LEAD AND CADMIUM CONTAINING PAINT SAMPLE REPORT" - FOR MORE INFORMATION.
ABATEMENT WORK NOT INCLUDED IN CONTRACT. TO BE COMPLETED BY OTHERS PRIOR TO THE START OF WORK. AREA EALUMINUM WINDOW SCHEDULE
TYPE
DETAILS
HEAD JAMB SILL REMARKS
A
B
C
D
E
F
G
D2 / A401 D3 / A401 C2 / A401 CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
H CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
J CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
K CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS., TINTED GLASS @ GYM WINDOWS.
L CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
WIDTH
15' - 0"
12' - 0"
10' - 0"
8' - 0"
7' - 4"
6' - 0"
6' - 0"
6' - 0"
4' - 0"
10' - 0"
6' - 0"
HEIGHT
6' - 0"
5' - 0"
6' - 8"
6' - 8"
6' - 8"
6' - 0"
4' - 4"
6' - 8"
4' - 4"
6' - 8"
5' - 0"
M CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.4' - 0" 5' - 0"
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
MASONRY OPENING
N CONTRACTOR TO VERIFY SIZE OF EXISTING R.O. PRIOR TO SHOP DWGS.6' - 0" 4' - 0" - - -
PROPOSED KEYNOTES -
1 AFTER WINDOW INSTALLATION, REINSTALL EXISTING ROLLER BLINDS, VERTICAL
BLINDS, OR CURTAINS AT EXISTING WINDOW OPENING.
BID ALT #1: REMOVE AND DISPOSE OF EXISTING ROLLER BLINDS, VERTICAL BLINDS,
AND CURTAINS. PROVIDE NEW MANUAL ROLLER SHADES w/ ROOM DARKENING FABRIC
TO PROVIDE MAXIMUM PRIVACY. PROVIDE A SQUARE FASCIA TOP TREATMENT WITH A
MANUAL PULL CHAIN. SHADE & FASCIA COLOR T.B.D. BY OWNER. CONTRACTOR SHALL
FIELD VERIFY WINDOW OPENINGS PRIOR TO ORDERING AND INSTALLATION.
BID ALT #1:
ALUM WINDOW SILL w/
WEEP PROVISIONS
CAULK AND
BACKER ROD
ALUM WINDOW
ALUM. FLASHING
SHIM AND INSULATE
BACKER
ROD/SEALANT CAULK AND
BACKER ROD
SHIM AND INSUL
ALUM WINDOW
EXISTING
METAL PANEL
EXISTING STEEL
FRAME BEYOND
VERIFY
8"
1 3 /4"
ALUMINUM FRAME
THERMALLY BROKEN
PER MFR
SEALANT AND
BACKER ROD
EACH SIDE
GLAZING
EXISTING METAL
FRAMING
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T
NO
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R
D
AT
E:
1 2 3 4 5
1 2 3 4 5
C :\U se rs
\ra nd er so n\ D oc um en ts
\B
3-
_B
AS
W in do w R ep la ce m en t_
C
EN
TR
AL
_R
_r an de rs on up ea
.c om
.rv t
9/
/2
:0 1:
A
M
A101.5
PROPOSED
FLOOR PLAN -
AREA E
B
AR
AG
A
AR
EA
S C
H O
O
LS
W
IN
DO
W
R
EP
LA
CE
ME
NT
0 L
YO
NS
S
TR
EE
T, B
AR
AG
A, M I 4
B1
-0
R M
A
JA R
M A
R M
A
BA
RA
GA
A
RE
A
SC
HO
OL
S
W
IN
DO
W
R
EP
LA
CE
M
EN
T
LA
R A
R
EV
IE
W
/1
1/
1/8" = 1'-0"A3 PROPOSED FLOOR PLAN - AREA E
NO SCALE- KEY PLAN
NORTH
3" = 1'-0"A1 WINDOW SILL DETAIL
3" = 1'-0"C1 WINDOW HEAD DETAIL
3" = 1'-0"B1 WINDOW JAMB DETAIL
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T
NO
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R
D
AT
E:
1 2 3 4 5
1 2 3 4 5
C :\U se rs
\ra nd er so n\ D oc um en ts
\B
3-
_B
AS
W in do w R ep la ce m en t_
C
EN
TR
AL
_R
_r an de rs on up ea
.c om
.rv t
9/
/2
:0 1:
A
M
A201
EXTERIOR
ELEVATIONS
B
AR
AG
A
AR
EA
S C
H O
O
LS
W
IN
DO
W
R
EP
LA
CE
ME
NT
0 L
YO
NS
S
TR
EE
T, B
AR
AG
A, M I 4
B1
-0
R M
A
JA R
M A
R M
A
BA
RA
GA
A
RE
A
SC
HO
OL
S
W
IN
DO
W
R
EP
LA
CE
M
EN
T
1/16" = 1'-0"C2 NORTH ELEVATION
1/16" = 1'-0"A4 EAST ELEVATION
1/16" = 1'-0"C1 SOUTH ELEVATION
1/16" = 1'-0"A2 WEST ELEVATION
1/16" = 1'-0"A1 SOUTH COURTYARD ELEV
1/16" = 1'-0"A3 NORTH COURTYARD ELEV
LA
R
A R
EV
IE
W
/1 1/
1/16" = 1'-0"D2 VOC ED - EAST ELEV
1/16" = 1'-0"D1 VOC ED - NORTH ELEV
1/16" = 1'-0"D3 VOC ED - SOUTH ELEV
1/16" = 1'-0"D4 VOC ED - WEST ELEV
VE
RI
FY
2'
- 6
SE
E
SC
HE
DU
LE
SEE SCHEDULE
2" 2"EQ 2" EQ 2" EQ 2" EQ
A
FIXED FIXED FIXEDFIXED
2'
- 1
T = TEMPERED GLASS
S = SECURITY FILM
STSTSTST
STSTSTST
F
VE
RI
FY
2'
- 6
SE
E
SC
HE
DU
LE
SEE SCHEDULE
2"EQ2"EQ2"
FIXED FIXED
2'
- 1
T = TEMPERED GLASS
S = SECURITY FILM
ST
ST
ST
ST
B
VE
RI
FY
3'
- 0
SE
E
SC
HE
DU
LE
SEE SCHEDULE
2"EQ2"EQ2"EQ2"EQ2"
FIXED FIXED FIXED FIXED
2'
- 1
T = TEMPERED GLASS
S = SECURITY FILM
ST
ST
ST
ST
ST
ST
ST
ST
VE
RI
FY
3'
- 4
SE
E
SC
HE
DU
LE
SEE SCHEDULE
2" EQ 2" EQ 2" EQ 2"
C
FIXED FIXED FIXED
2'
- 1
T = TEMPERED GLASS
S = SECURITY FILM
ST
ST
ST
ST
ST
ST
VE
RI
FY
2'
- 6
SE
E
SC
HE
DU
LE
SEE SCHEDULE
2"EQ2"EQ2"
D
FIXED FIXED
2'
- 1
T = TEMPERED GLASS
S = SECURITY FILM
ST
ST
ST
ST
SE
E
SC
HE
DU
LE
VE
RI
FY
4'
- 4
SEE SCHEDULE
2"EQ2"EQ2"
E
FIXED FIXED
2'
- 1
T = TEMPERED GLASS
S = SECURITY FILM
ST
ST
VE
RI
FY
2'
- 6
SE
E
SC
HE
DU
LE
SEE SCHEDULE
2" EQ 2" EQ 2"
H
FIXED FIXED
2'
- 1
T = TEMPERED GLASS
S = SECURITY FILM
ST
ST
ST
ST
ALUMINUM WINDOW SCHEDULE
TYPE
DETAILS
HEAD JAMB SILL REMARKS
A
B
C
D
E
F
G
D2 / A401 D3 / A401 C2 / A401 CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
H CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
J CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
K CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS., TINTED GLASS @ GYM WINDOWS.
L CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.
WIDTH
15' - 0"
12' - 0"
10' - 0"
8' - 0"
7' - 4"
6' - 0"
6' - 0"
6' - 0"
4' - 0"
10' - 0"
6' - 0"
HEIGHT
6' - 0"
5' - 0"
6' - 8"
6' - 8"
6' - 8"
6' - 0"
4' - 4"
6' - 8"
4' - 4"
6' - 8"
5' - 0"
M CONTRACTOR TO VERIFY SIZE OF EXISTING M.O. PRIOR TO SHOP DWGS.4' - 0" 5' - 0"
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
D2 / A401 D3 / A401 C2 / A401
MASONRY OPENING
N CONTRACTOR TO VERIFY SIZE OF EXISTING R.O. PRIOR TO SHOP DWGS.6' - 0" 4' - 0" - - -
FIXED FIXED
VE
RI
FY
3'
- 0
SE
E
SC
HE
DU
LE
SEE SCHEDULE
2" EQ 2" EQ 2"
2'
- 1
G T = TEMPERED GLASS
S = SECURITY FILM
ST
ST
ST
ST
FIXED
SEE SCHEDULE
SE
E
SC
HE
DU
LE
VE
RI
FY
3'
- 0
2'
- 1
J T = TEMPERED GLASS
S = SECURITY FILM
ST
ST
FIXED FIXED FIXED FIXED
SEE SCHEDULE
2" EQ 2" EQ 2" EQ 2" EQ 2"
SE
E
SC
HE
DU
LE
2" 2"
K T = TEMPERED GLASS
T2 = TINTED GLASS @ GYM WINDOWS
T2T
VA
RI
ES
SI
LL
TTT T2T2T2
L
FIXED FIXED
SE
E
SC
HE
DU
LE
VE
RI
FY
3'
- 0
2'
- 1
SEE SCHEDULE
2" EQ 2" EQ 2"
T = TEMPERED GLASS
S = SECURITY FILM
ST
ST
ST
ST
FIXED
SEE SCHED.
SE
E
SC
HE
DU
LE
VE
RI
FY
3'
- 0
2'
- 1
2" 2"
T = TEMPERED GLASS
S = SECURITY FILM
ST
ST
M
A401 C2
A401 D2
FI
EL
D
VE
RI
FY
VA
RI
ES
TY
PI
CA
L 2'
- 1
SE
E
SC
HE
DU
LE
VA
RI
ES
2'
- 0
4"
SE
E
SC
HE
DU
LE
VA
RI
ES
1"
1/2
1/2
FIELD VERIFY
VARIES
EXISTING CMU
SHIM & INSULATE
ALUM. WINDOW
w/ TEMPERED
GLAZING
SEALANT
EXISTI…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .