B08_Solicitation_(Attachment_2_-Drawings_-_31_pages).pdf
PDF 20 MB Posted
- Attached to
- HOME, Install Fire Suppression System EC Federal contract opportunity
- Solicitation number
- 140P6023B0003
About this file
This solicitation is for the installation of a fire suppression system at the Midwest Region of the National Park Service. The solicitation number is 140P6023B0003 and seeks to install a fire suppression system at HOME to protect life and property. Offerors should submit proposals by the deadline of [DATE] to be considered for the award, which is expected to be made by [DATE]. The work includes drawing and installing piping, sprinklers, alarms and related components in accordance with 31 attached drawings. Relevant experience with fire suppression projects for government agencies is preferred. Small businesses are encouraged to compete.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140P6023B0003_Amd_0001.pdf | ||
| B11_MISC_(Contractor_Questions_-_NPS_Response)_0001.pdf | ||
| B08_Solicitation_(Attachment_1_-_Project_Specifications_-_14_pages).pdf | ||
| Sol_140P6023B0003.pdf | ||
| B08_Solicitation_(Attachment_5_-_Limitations_on_Subcontracting_Report).xlsx | XLSX spreadsheet | |
| B08_Solicitation_(Attachment_4_-_Submittal_List_-_3_pages).pdf | ||
| B08_Solicitation_(Attachment_3_-_Construction_Wage_Determination_-_6_pages).pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PATIO
S
ID
E W A L K
SIDEWALK
EDUCATION CENTER
BLDG NO. 1
U T
IL
IT
Y
B L D G
N O
R E S
ID
E N C E
B L D G
N O
R E S
ID
E N C E
B L D G
N O
CABIN
SITE LOCATION
LOCATION OF WORK
STAGING AREA:
LIMIT OF 5 PARKING STALLS AND 15'X30'
TURF AND AGGREGATE CAMPER PAD
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
207662
80056
CA0666
I, AM THE COORDINATING
PROFESSIONAL ON:
D R e v it te m p
\0
-M E
C H
R m b e c k m a n n s c h e m m e r.
c o m .r v t
JEK
MLB
Checker
12/15/2022
07310.024
COVER SHEET
Home Education Center Fire Suppression
Homestead National Historic Park
8523 NE-4
Beatrice, NE 68310
CONSTRUCTION DRAWINGS
12/15/2022
07310024- 0- 0 COVER SHEET
Home Education Center Fire Suppression Homestead National Historic Park
8523 NE-4
Beatrice, NE 68310
JEFFERY E. KULHANEK
National Park Service
Home Education Center Fire Suppression
DRAWING INDEX
NOT TO SCALE
VICINITY MAP
NOT TO SCALE
PARK MAP
GENERAL
0 COVER SHEET
FP100 SITE PLAN AND NOTES - FIRE PROTECTION
FIRE PROTECTION
FP101 FLOOR PLAN - FIRE PROTECTION
FP102 ATTIC PLAN - FIRE PROTECTION
FP103 FIRE PUMP - FIRE PROTECTION
CIVIL
C 00 SITE SPECIFICATIONS & GENERAL NOTES
FA100 SITE PLAN AND NOTES - FIRE ALARM
FIRE ALARM
FA101 FLOOR PLAN - FIRE ALARM
FA102 FLOOR PUMP PLAN - FIRE ALARM
NOT TO SCALE
STAGING MAP
C101 SITE LAYOUT & UTILITY PLAN
C201 SITE DETAILS
ARCHITECTURAL
A 00 ARCHITECTURAL INFO SHEET
A 01 ARCHITECTURAL SPECS
A02
A401 SECTIONS, DETAILS
STRUCTURAL
S 00 STRUCTURAL INFO SHEET
S 01 STRUCTURAL SPECS
S101 STRUCTURAL PLANS
S201 FOUNDATION DETAILS
S301 FRAMING DETAILS
FA103 SPECIFICATIONS - FIRE ALARM
FP104 SPECIFICATIONS - FIRE PROTECTION
FP105 SPECIFICATIONS - FIRE PROTECTION
E 00 ELECTRICAL INFO SHEET
ELECTRICAL
E 01 ELECTRICAL SPECIFICATIONS
E 02 ELECTRICAL SPECIFICATIONS
E 03 ELECTRICAL SPECIFICATIONS
E 04 ELECTRICAL SPECIFICATIONS
E101 FLOOR PLANS - ELECTRICAL
E501 ELECTRICAL DETAILS
A101 FLOOR PLANS, ELEVATIONS, SCHEDULES
A401 SECTIONS, DETAILS
ARCHITECTURAL SPECS
DATE INITIAL
jkulhanek KM_C224e-20191028135059 jkulhanek KM_C224e-20190905063045 jkulhanek Typewritten Text 12/16/22
1044 North 115th Street | Suite 300 Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
DATE INITIAL
HOMESTEAD NATIONAL MONUMENT OF AMERICA
8523 NE-4
BEATRICE, NE 68310
207662
80056
07310.024
12/15/2022 31
EDUCATION CENTER FIRE SERVICE
100% CD
MOM
ALN
C 00
SITE SPECIFICATIONS &
GENERAL NOTES
RMD
07310024-C 00 SITE SPECIFICATIONS & GENERAL NOTES
SF12/15/2022
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
DATE INITIAL
HOMESTEAD NATIONAL MONUMENT OF AMERICA
8523 NE-4
BEATRICE, NE 68310
207662
80056
07310.024
12/15/2022 31
EDUCATION CENTER FIRE SERVICE
100% CD
MOM
ALN
C101
SITE LAYOUT & UTILITY
PLAN
RMD
07310024-C101 SITE LAYOUT & UTILITY PLAN
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
DATE INITIAL
HOMESTEAD NATIONAL MONUMENT OF AMERICA
8523 NE-4
BEATRICE, NE 68310
207662
80056
07310.024
12/15/2022 31
EDUCATION CENTER FIRE SERVICE
100% CD
MOM
ALN
RMD C201
SITE DETAILS
07310024-C201 SITE DETAILS
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
207662
80056
CA0666
C U s e rs
\n b o e s c h
\D o c u m e n ts \0
-A R
C H
R n b o e s c h
.r v t
SMW
SMW
RJL
12/15/2022
07310.024
A 00
ARCHITECTURAL INFO
SHEET
07310024- 2- A 00 ARCHITECTURAL INFO SHEET
EDUCATION CENTER FIRE SERVICE
HOMESTEAD NATIONAL MONUMENT OF AMERICA
8523 NE-4
BEATRICE, NE 68310
XXXX
DX
XREFERENCE
NOTE
REFERENCE
DEMOLITION
NOTE
EQUIPMENT
NUMBER
ROOM NAME
150 SF
ROOM
NUMBER
REFERENCE
DESIGNATION
DEMOLITION
DESIGNATION
EQUIPMENT
NUMBER
ROOM NAME
DESIGNATION
ROOM NUMBER
DESIGNATION
ROOM AREA
DESIGNATION
SYMBOL LEGEND
ROOM /
FRAMING
ELEVATION
EXTERIOR
ELEVATION
XX-XX
XX-XX
ELEVATION LETTER
DIRECTION OF VIEW
SHEET NUMBER
ELEVATION LETTER
DIRECTION OF VIEW
SHEET NUMBER
DOOR
NUMBER
DOOR NUMBER10
WINDOW
DESIGNATION
WINDOW DESIGNATION000
TA-X
TOILET
ACCESSORY
TOILET ACCESSORY
NUMBER
WALL
TYPE
LETTER
INDICATES
PARTITION OR
WALL TYPE
X
ABBREVIATIONS
REFERENCE LEGEND
PLAN VIEW
SECTION / ELEVATION VIEW
SHEAR WALL
MASONRY-CMU
MASONRY-VENEER
STUD WALL
CONCRETE
GRAVEL
EARTH / COMPACTED
EARTH /
NONCOMPACTED
RIGID INSULATION
JOINT FILLER
STEEL
GYPSUM
FLEXIBLE INSULATION
GROUT
PLYWOOD
WOOD (FINISH)
MASONRY-CMU FACE
MASONRY-CMU
MASONRY-VENEER
ARCHITECTURAL SHEET LIST
X
PROJECT ARCHITECTURAL REFERENCED NOTES
REF. NOTES ( )
S SOUTH
SA SUPPLY AIR
SAN SANITARY
SB SECURITY BARS
SB SPLASH BLOCK
SCH SCHEDULE
SCHED SCHEDULE
SCR SCREW
SCT STRUCTURAL CLAY TILE
SCUT SCUTTLE
SCW SOFT COLD WATER
SD STORM DRAIN
SD SUBDRAIN
SDI STEEL DECK INSTITUTE
SECT SECTION
SECY SECRETARY
SEQ SEQUENCE
SF SQUARE FOOT (FEET)
SFU STRUCTURAL FACING
UNIT
SHLD SHOULDER
SHT SHEET
SHTG SHEATHING
SHW SOFT HOT WATER
SIM SIMILAR
SJI STEEL JOIST INSTITUTE
SL SNOW LOAD
SLBB SHORT LEG BACK TO
BACK
SM SPRINKLER MAIN
SOV SHUT OFF VALVE
SPA SPACE(ING)
SPEC SPECIFICATIONS
SPF SOUNDPROOF
SPH SPACE HEATER
SPKR SPEAKER
SPL SPECIAL
SQ SQUARE
SS SANITARY SEWER
SS STAINLESS STEEL
SSMR STANDING SEAM METAL
ROOFING
STA STATION
STAIR STAIRWAY
STC SOUND TRANSMISSION
COEFFICIENT
STD STANDARD
STGR STRINGER
STIFF STIFFENER
STIRR STIRRUPS
STL STEEL
STN STONE
STOR STORAGE
STR STRUCTURAL
SUB FL SUB FLOOR
SUCT SUCTION
SUSP SUSPENDED
SVF SHEET VINYL FLOORING
SW SWITCH
SWBD SWITCH BOARD
SYM SYMMETRICAL
T TREAD
T or TLT TOILET
TAN TANGENT
TBD TACK BOARD
TE TOP ELEVATION
TEL TELEPHONE
TEMP TEMPERATURE
TER TERRAZZO
TERM TERMINAL
TGL TOGGLE
TH THRESHOLD
THK THICK
THRD THREAD
TO TOP OF
TOB TOP OF BEAM
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOJ TOP OF JOIST
TOPO TOPOGRAPHIC
TOS TOP OF STEEL
TOW TOP OF WALL
TRANS TRANSVERSE
TSTAT THERMOSTAT
TV TELEVISION
TW TEMPERED WATER
TWR TEMPERED WATER
RETURN
TYP TYPICAL
UC UNIT COOLER
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITERS
LABORATORIES
UNEX UNEXCAVATED
UNFIN UNFINISHED
UNO UNLESS NOTED
OTHERWISE
UPS UNINTERRUPTIBLE
POWER SYSTEM
UR URINAL
UT UTILITY
UV UNIT VENTILATOR
V VOLT
VAC VACUUM
VAV VARIABLE AIR VOLUME
VCP VITRIFIED CLAY PIPE
VCT VINYL COMPOSITION TILE
VD VAULT DOOR
VEL VELOCITY
VENT VENTILATOR(ION)
VERT VERTICAL
VEST VESTIBULE
VFD VARIABLE FREQUENCY
DRIVE
VOL VOLUME
VPC VERTICAL POINT OF
CURVATURE
VPI VERTICAL POINT OF
INTERSECTION
VPT VERTICAL POINT OF
TANGENCY
VS VENT STACK
VT VINYL-TILE
VTR VENT THRU ROOF
VWC VINYL WALL COVERING
W WEST
W WIDE (WIDTH)
W WIRE
W/ WITH
W/O WITHOUT
WB WET BULB
WC WATER CLOSET
WC WATER COLUMN
WD WASTE DRAIN
WD WOOD
WD BLKG WOOD BLOCKING
WD DR WOOD DOOR
WDW WINDOW
WF WIDE FLANGE
WG WIRE GLASS
WH WALL HYDRANT
WHT WHITE
WI WROUGHT IRON
WKSH WORK SHOP
WL WIND LOAD
WNSCT WAINSCOT
WP WEATHER PROOF
WP WORK POINT
WPF WATER PROOF
WPFG WATER PROOFING
WRB WARDROBE
WS WASTE STACK
WT WEIGHT
WWF WELDED WIRE FABRIC
WWM WOVEN WIRE MESH
XFMR TRANSFORMER
YD YARD or YARD DRAIN
P PAINT
PA PUBLIC ADDRESS
PBS PUSH BUTTON STATION
PC PIECE
PC POINT OF CURVATURE
PC PRECAST
PCC PORTLAND CEMENT
CONCRETE
PCT PORCELAIN CERAMIC TILE
PD PRESSURE DROP
PE POLYETHYLENE
PEN PENETRATION
PERF PERFORATED
PH PHASE
PHAR PHARMACY
PI POINT OF INTERSECTION
PIV POST INDICATING VALVE
PL or P PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLATF PLATFORM
PLBG PLUMBING
PLG PILING
PLWD PLYWOOD
PNL PANEL
POL POLISH(ED)
PORC PORCELAIN
PPM PARTS PER MILLION
PR PAIR
PREFAB PREFABRICATED
PREFIN PREFINISHED
PRESS PRESSURE
PROJ PROJECT
PRV PRESSURE REGULATING
VALVE
PS PRESSED STEEL
PSFT POUNDS PER SQUARE
FOOT
PSI POUNDS PER SQUARE
INCH
PT POINT
PT POINT OF TANGENCY
PTD PAINTED
PTN PARTITION
PVC POLYVINYL-CHLORIDE
PVMT PAVEMENT
PW PASS WINDOW
1/4 RD QUARTER ROUND
QT QUARRY TILE
QT QUART
QTRS QUARTERS
QTY QUANTITY
QTZ QUARTZ
R REGISTER
R RISER
RA RETURN AIR
RAD OR
R
RADIUS
RB RESILIENT BASE
RC REMOTE CONTROL
RCP REINFORCED CONCRETE
PIPE
RD ROOF DRAIN
RE RIGHT END
REC RECEIVER
RECP RECEPTACLE
RECR RECREATION
RECT RECTIFIER
REF REFERENCE
REFR REFRIGERANT
REFR REFRIGERATOR
REG REGISTER
REINF REINFORCEMENT
REM REMOVE(ABLE)
REQD REQUIRED
RESIL RESILIENT
REV REVISIONS
RFG ROOFING
RH RELATIVE HUMIDITY
RL REFRIGERANT LIQUID
RM ROOM
RND ROUND
RO ROUGH OPENING
RPM REVOLUTIONS PER
MINUTE
RT RUBBER TILE
RTU ROOF TOP UNIT
RUB RUBBER
DIAG DIAGONAL
DIM DIMENSION
DIP DUCTILE IRON PIPE
DISC DISCONNECT
DIST DISTRIBUTION
DL DEAD LOAD
DMPR DAMPER
DN DOWN
DP DAMP PROOFING
DPT DEW POINT
DR DOOR
DRN DRAIN
DS DOWN SPOUT
DV DENTAL VACUUM
DWG DRAWING
DWLS DOWELS
DX DIRECT EXPANSION
E EAST
EA EACH
EA EXHAUST AIR
EDH ELECTRIC DUCT HEATER
EER ENERGY EFFICIENCY
RATIO
EJ EXPANSION JOINT
EL OR
ELEV
ELEVATION - GRADE OR
BUILDING
ELEC ELECTRIC OR ELECTRICAL
ELEV ELEVATOR
ENCL ENCLOSURE
ENT ENTERING
ENT ENTRANCE
EQ EQUAL
EQUIP EQUIPMENT
ES EACH SIDE
EST ESTIMATE
EVAP EVAPORATOR
EW EACH WAY
EWC ELECTRIC WATER
COOLER
EXC EXCAVATE
EXD EXIT DEVICE
EXH EXHAUST
EXIST EXISTING
EXP EXPOSED
EXPL EXPLOSION
EXPN EXPANSION
EXT EXTERIOR
F FAHRENHEIT
F
FIRE
FA FRESH AIR
FCG FACING
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEB FIRE EXTINGUISHER
BRACKET
FEC FIRE EXTINGUISHER
CABINET
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIG FIGURE
FIN FINISH
FIX FIXTURE
FL or FLR FLOOR
FLASH FLASHING
FLEX FLEXIBLE
FLG FLANGE
FLG FLOORING
FLUOR FLUORESCENT
FP FIRE PROTECTION
FPM FEET PER MINUTE
FPRF FIRE PROOF
FR FRAME
FRG FURRING
FS FAR SIDE
FS FLOOR SINK
FS FULL SIZE
FT FEET (FOOT)
FTG FOOTING
FV FIELD VERIFY
FWC FABRIC WALL COVERING
G GRILLE
G NATURAL GAS
GA GAGE OR GAUGE
GAL GALLON
GALV GALVANIZED
GEN GENERAL
GFE GOVERNMENT FURNISHED
EQUIPMENT
GFE/CI GOVERNMENT FURNISHED
EQUIPMENT/CONTRACTOR
INSTALLED
GFI GROUND FAULT
INTERRUPTER
GI GALVANIZED IRON
GL GLASS
GND GROUND
GOVT GOVERNMENT
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GR GRADE
GRS GALVANIZED RIGID STEEL
CONDUIT
GRTG GRATING
GSU GLAZED STRUCTURAL
UNITS
GWB GYPSUM WALLBOARD
GWT GLAZED WALL TILE
GYP GYPSUM
H or HT HEIGHT (HIGH)
HB HOSE BIBB
HBD HARDBOARD
HC HANDICAPPED
HD HEAD
HDPE HIGH DENSITY
POLYETHYLENE
HDR HEADER
HDW HARDWARE
HIP HIGH PRESSURE
HM HOLLOW METAL
HORIZ HORIZONTAL(LY)
HP HORSE POWER
HPS HIGH PRESURE STEAM
HPT HIGH POINT
HR HOUR
HS HIGH STRENGTH
HSGYP HIGH STRENGTH GYPSUM
PLASTER
HTG HEATING
HTR HEATER
HW HEAD WALL
HW HOT WATER
HWH HOT WATER HEATER
HWR HOT WATER RETURN
(HEATING)
HWS HOT WATER SUPPLY
(HEATING)
HYD HYDRAULIC
I or FE IRON
IC INTERCOM
ID INSIDE DIAMETER
IE INVERT ELEVATION
IES ILLUMINATING
ENGINEERING SOCIETY
IN INCH
INSUL INSULATION
INT INTERIOR
INV INVERT OR INVERTER
IP IRON PIPE
ISF INSIDE FACE
JB JUNCTION BOX
JBOX JUNCTION BOX
JC JANITOR CLOSET
JCT JUNCTION
JST JOIST
JT JOINT
K KEY
KCP KEENE'S CEMENT
PLASTER
KIP or K KILOPOUND (1000 LBS)
KIT KITCHEN
KL KEY LOCK
KP KICK PLATE
KV KILOVOLTS
KVA KILOVOLT AMPERES
KW KILOWATT
LAB LABORATORY
LAU LAUNDRY
LAV LAVATORY
LBR LUMBER
A COMPRESSED AIR
A/C AIR CONDITIONING
AB ANCHOR BOLT
ABS ACRYLONITRILE BUTAD
STYRENE
AC ALTERNATING CURRENT
ACI AMERICAN CONCRETE
INSTITUTE
ACSR ALUMINUM CONDUCTOR
STEEL REINFORCED
ACST ACOUSTIC
AD ACCESS DOOR
AD AREA DRAIN
ADMIN ADMIN ADMINISTRATION
(IVE)
AFF ABOVE FINISH FLOOR
AFFF AQUEOUS FILM FORMING
FOAM
AGG AGGREGATE
AHU AIR HANDLING UNIT
AI AREA INLET
AIC AMPS INTERRUPTING
CAPACITY (SYM RMS)
AISC AMERICAN INSTITUTE OF
STEEL CONSTRUCTION
AL ACTIVE LEAF
AL ALUMINUM
ALT ALTERNATE
AMP AMPERE
ANSI AMERICAN NATIONAL
STANDARDS INSTITUTE
AP ACCESS PANEL
APD AIR PRESSURE DROP
APPD APPROVED
APPROX APPROXIMATE
ARCH ARCHITECTURAL OR
ARCHITECT
ARI AMERICAN
REFRIGERATION
INSTITUTE
ASB ASBESTOS
ASPH ASPHALT
APC ACOUSTICAL PANEL
CEILING
AUTO AUTOMATIC
AV ACID VENT
AVG AVERAGE
AW ACID WASTE
AWC ACOUSTICAL WALL
COVERING
AWG AMERICAN WIRE GAUGE
L ANGLE
BATT BATT INSULATION
BB BULLETIN BOARD
BBO BOILER BLOW OFF
BC BOOKCASE
BD BOARD
BDY BOUNDARY
BEJ BRICK EXPANSION JOINT
BIT BITUMINOUS
BKR BREAKER
BL BUILDING LINE
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BM BENCH MARK
BO BOTTOM OF
BOT BOTTOM
BRCG BRACING
BRDG BRIDGING
BRG BEARING
BRK BRICK
BRKT BRACKET
BS BOTH SIDES
BTU BRITISH THERMAL UNIT
BTUH BTU PER HOUR
BUR BUILT-UP ROOFING
BW BOTH WAYS
C CENTER
C OR
CND
CONDUIT (ELECTRICAL
SHEETS)
C TO C CENTER TO CENTER
CAP CAPACITY
CB CATCH BASIN (OR CIRCUIT
BREAKER)
CC CENTER TO CENTER
CCT CIRCUIT
CD CONDENSATE DRAIN
CE COVER ELEVATION
CEM CEMENT
CF CUBIC FEET
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CHIM CHIMNEY
CI CAST IRON
CI CURB INLET
CIP CAST IN PLACE
CIR CIRCULAR
CJ CONTROL JOINT
CKT CIRCUIT
CL CENTER LINE
CL WG CLEAR WIRE GLASS
CLG CEILING
CLKG CAULKING
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY
UNIT
CNTR COUNTER
CO CLEAN OUT
CO2 CARBON DIOXIDE
COL COLUMN
COM COMMON
COMB COMBINATION
COMB COMBUSTION
COMP COMPRESSIBLE
COMPR COMPRESSOR
CONC CONCRETE
CONF CONFERENCE
CONN CONNECTION
CONSTR CONSTRUCTION
CONSTR
JT
CONSTRUCTION JOINT
CONT CONTINUOUS
(CONTINUATION)
CONTR CONTRACTOR
COR CORNER
CORR
COVEREDCOV
CORRIDOR
CPL CEMENT PLASTER
CPS CYCLES PER SECOND
(HERTZ)
CPT CARPET
CR CONDENSER WATER
RETURN
CRES CORROSIVE RESISTANT
STEEL
CRG CARRIAGE
CRSE COURSE
CS CONDENSER WATER
SUPPLY
CS COUNTER SINK
CSMT CASEMENT
CT CERAMIC TILE
CT CURRENT TRANSFORMER
CTL CARPET TILE
CU CONDENSING UNIT
CU YD CUBIC YARDS
CUH CABINET UNIT HEATER
CV CEILING VENT
CW COLD WATER
CWR CHILLED WATER RETURN
CWS CHILLED WATER SUPPLY
CYL CYLINDER
D DEPTH (DEEP)
D DIFFUSER
d PENNY (as in nail - 10d)
D&M DRESSED AND MATCHED
DA DOUBLE ACTING
DB DRY BULB
dB DECIBEL
DBL DOUBLE
DC DIRECT CURRENT
DCJ DOWELED CONTROL
JOINT
DCJT DUMMY CONTROL JOINT
DCL DOOR CLOSER
DCW DOMESTIC COLD WATER
DEG DEGREE
DEMO DEMOLITION
DEPR DEPRESSION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DH DOUBLE HUNG
DHW DOMESTIC HOT WATER
DI DEIONIZED WATER
DIA DIAMETER
CLO CLOSET
FR FIRE RATED
U/C UNDER CABINET
CBU CEMENTITIOUS BACKER
UNIT
F FLUSH or FRAME
FG FULL GLASS
G GLASS or GLASS TYPE
HG HALF GLASS
V VISION
SL SLIDING
BF(2) BIFOLD (DOUBLE)
IG INSULATED GLASS
SS SOLID SURFACE
WIDTH DEPTH
HEIGHT
CABINET DESIGN
SERIES MODELCASEWORK
TAG
DWR DRAWER
CAB CABINET
SHV SHELF OR SHELVES
SNGL SINGLE
GENERAL NOTES
LBS POUNDS
LD LOAD
LDG LOADING
LE LEFT END
LG LENGTH (LONG)
LIN LINEAR
LIS LAWN IRRIGATION
SYSTEM
LL LIVE LOAD
LLBB LONG LEG BACK TO BACK
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LNTL LINTEL
LP LOW POINT
LPG LIQUIFIED PETROLEUM
GAS
LPS LOW PRESSURE STEAM
LR LIVING ROOM
LS LAWN SPRINKLER
LT LIGHT
LT WT LIGHT WEIGHT
LTG LIGHTING
LVT LUXURY VINYL TILE
M MIDDLE
M THOUSAND
M & B MATCHED AND BEADED
MA MAKE-UP AIR
MACH MACHINE
MAS MASONRY
MAT or
MATL
MATERIAL
MAX MAXIMUM
MB MACHINE BOLT
MBH 1000 BTUH
MC MEDICINE CABINET
MC MISCELLANEOUS
CHANNELS
MECH MECHANICAL
MER MECHANICAL EQUIPMENT
ROOM
MET METAL
MFG MANUFACTURING
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
ML METAL LATH
MLDG MOULDING
MO MASONRY OPENING
MONO MONOLITHIC
MT METAL THRESHOLD
MTD MOUNTED
N NORTH
NC NORMALLY CLOSED
NEC NATIONAL ELECTRICAL
CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURERS
ASSOCIATION
NFPA NATIONAL FIRE
PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NO NUMBER
NR NOT REQUIRED
NS NEAR SIDE
NTS NOT TO SCALE
OA OUTSIDE AIR
OB WG OBSCURE WIRE GLASS
OBGL OBSCURE GLASS
OBSC OBSCURE
OC ON CENTER(S)
OCEW ON CENTER EACH WAY
OD OUTSIDE DIAMETER
OFF OFFICE
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OPS OPERATIONS
OS & Y OUTSIDE SCREW & YOKE
OSF OUTSIDE FACE
OV OVERFLOW VALVE
OX OXYGEN
OZ OUNCE
NV NARROW VISION
MICRO MICROWAVE
NORTH
ARROW
NAME
ELEVATION
LEVEL
MATCHLINE
AREA A
AREA B
TITLE
MARKER
VIEW NAME
SCALE: 1/8" = 1'-0"
EXISTING
COLUMN
NEW
COLUMN
X
X
X
XX-XX
SIM
X
XX-XX
SECTION/
DETAIL
PLAN
DETAIL
LETTER INDICATES
NEW COLUMN LINE
LETTER INDICATES
EXISTING COLUMN LINE
SECTION/DETAIL
NUMBER
SHEET NUMBER
INDICATES DIRECTION
OF VIEW
DETAIL NUMBER
SHEET NUMBER
DETAIL NUMBER
LEVEL CALLOUT
DESIGNATION
ELEVATION
DESIGNATION
GRAPHIC AREA FOR
DRAWING
TITLE
SCALE OF THE
DRAWING
NORTH PLAN
NORTH
TRUE
NORTH
APPLICABLE CODE NOTES:
A 00 ARCHITECTURAL INFO
SHEET
A 01 ARCHITECTURAL SPECS
A 02 ARCHITECTURAL SPECS
A101 FLOOR PLANS,
ELEVATIONS, SCHEDULES
A401 SECTIONS, DETAILS
A. EXISTING CONDITIONS ARE BASED ON DRAWINGS PROVIDED BY THE OWNER AND LIMITED FIELD VERIFICATION. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS AND NOTIFY THE CONTRACTING OFFICER OF ANY DISCREPANCIES OR VARIATIONS FROM THOSE SHOWN
ON THE DRAWINGS. THE CONTRACTOR SHALL ADJUST TO ACTUAL FIELD CONDITIONS AT NO
ADDITIONAL EXPENSE TO THE OWNER.
B. ALL CONTRACTORS ARE RESPONSIBLE FOR REVIEWING ENTIRE SET OF DOCUMENTS TO DETERMINE
THEIR FULL SCOPE OF WORK.
C. CONTRACTOR SHALL TAKE ALL MEASUREMENTS FOR WORK AND BE RESPONSIBLE FOR SAME.
CONTRACTOR SHALL ADJUST FOR ACTUAL FIELD CONDITIONS. COORDINATE THE WORK AND SHOP
DRAWINGS WITH ALL OTHER TRADES AFFECTED.
D. SCREENED HALF-TONE LINES INDICATE EXISTING CONSTRUCTION TO REMAIN. FULL-TONE LINES
INDICATE NEW OR RELOCATED CONSTRUCTION.
E. BUILDING ELEVATION XXX.X' ON THE SITE PLAN EQUALS ELEVATION 100'-0" ON THE ARCHITECTURAL
PLANS.
F. DIMENSIONS ARE TYPICALLY TO FINISH FACE OF MASONRY, CONCRETE, GYPSUM WALL BOARD, AND
METAL FRAMES; OR CENTER LINE OF COLUMN OR BEAMS, UNLESS NOTED OTHERWISE.
G. ALL ANGLES ON THE FLOOR PLANS ARE 45 OR 90 DEGREES UNLESS OTHERWISE INDICATED.
H. SEE SHEET A101 FOR DOOR AND ROOM FINISH SCHEDULES.
I. SEE SHEET A101 FOR PARTITION TYPES AND NOTES.
1 STRUCTURAL STOOP, SEE STR.
2 PREFINISHED MET DOWNSPOUT
3 6" METAL GUTTER WITH 4"X6" METAL DOWNSPOUTS
4 OUTLINE OF ROOF ABOVE
5 OUTLINE OF BUILDING BELOW
6 36" X 36" ROOF HATCH WITH CRICKETS AS REQUIRED ON THE HIGH SIDE OF OPENING- ROOF HATCH
TO OPEN FULLY TO ALLOW REMOVAL OF TURBINE FIRE PUMP. COORDINATE ROOF HATCH
LOCATION WITH EQUIPMENT.
7 PRECAST CONC. SPLASHBLOCK
8 CONC CURB - SEE STR
9 MECH ROOF PENETRATION - COORDINATION LOCATION WITH FIRE PROTECTION SHEETS AND
EQUIPMENT
5 31
CODE SUMMARY
APPLICABLE CODES
BUILDING :
ACCESSIBILITY :
ENERGY :
OCCUPANCY GROUP :
TYPE OF CONSTRUCTION :
FIRE SEPARATION ASSEMBLIES
EXITS
ROOF CONSTRUCTION
FLOOR CONSTRUCTION
FIRE WALLS
FIRE RESISTANCE OF STRUCTURAL
ELEMENTS
RATING
(HOURS)
DESIGN
NUMBER
EXTERIOR WALLS
LOAD BEARING WALLS
NON-LOAD BEARING WALLS
U
VB
2010 ADA
NA
2021 IECC
2021 IBC
OFFICE
TOTAL
AREA (GROSS SQUARE FOOTAGE) :
BUILDING STATISTICS
NUMBER OF STORIES :
184 SF
184 SF
DATE INITIAL
nboesch KM_C224e-20221215171124
SECTION 073110 - SHINGLES
PART 1 - GENERAL
1.1 SECTION INCLUDES
A. Multi-Width Synthetic shake shingles, underlayment, flashings, fasteners, and accessories
1.2 RELATED SECTIONS
A. Section 076200 - Flashing and Sheet Metal
1.3 REFERENCES
A. American Society for Testing and Materials (ASTM)
1. ASTM D 226 - Standard Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing
2. ASTM E 108 (UL 790) - Standard Test Methods for Fire Tests of Roof Coverings
B. Underwriters Laboratories (UL)
1. ASTM E 108 (UL 790) - Standard Test Methods for Fire Tests of Roof Coverings
C. International Code Council (ICC): ES Acceptance Criteria AC07 Section 4.9
1.4 PERFORMANCE REQUIREMENTS
A. Shake roof system to consist of manufactured synthetic shakes attached to structural substrate to form weather tight roof envelope with no measurable water penetration B. Shakes shall be manufactured with variations in size, textured faces and edges, and no less than ¾” thickness to provide a realistic installed appearance C. Shakes shall be manufactured with no variation in color D. Method of attachments shall be designed to adequately resist wind uplift for roof configuration and project location
1.5 SUBMITTALS
A. Product Data: Manufacturer's data sheets on each product to be used, including:
1. Shingles, underlayment, flashings, fasteners, and accessories indicating composition, properties, and dimensions. Provide data showing compliance with specified requirements
2. Preparation instructions and recommendations
3. Storage and handling requirements and recommendations
4. Installation methods
B. Shop Drawings: Drawings illustrating shingle layout, method of attachment, flashings, trim, conditions at eaves, intersections with adjacent materials, and other installation details C. Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and surface textures D. Verification Samples: For each finish product specified, two samples, representing actual product, color, and texture
1.6 QUALITY ASSURANCE
A. Manufacturer Qualifications: Company specializing in manufacturer of synthetic shingles B. Installer Qualifications: Company specializing in installing shingle roof systems with 5 years minimum experience
1.7 DELIVERY, STORAGE, AND HANDLING
A. Ship in bundles of shingles. Bundles shall be assembled such that sorting at job site is not required B. Deliver shingles to site in manufacturer's unopened, labeled bundles. Promptly verify quantities and condition. Immediately remove damaged products from site C. Store products in protected environment, clear of ground, moisture, UV, and protected from traffic and construction activities.
Store shingles on edge no more than 2 pallets high, do not store flat. Do not store on site for prolonged period unless weather and UV protected D. Store synthetic shake products at temperature between 40- and 120-degrees F E. Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction
1.8 PROJECT CONDITIONS
A. Anticipate and observe environmental conditions (temperature, humidity, and moisture) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits
1.9 WARRANTY
A. Warranty Requirements:
1. Manufacturer's 50 years warranty for manufacturing defects that results in leaks under normal weather and use conditions
2. Installer's 2 years total roof system warranty including underlayment, flashings, trim, and other roof components against water penetration
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Acceptable Manufacturer: CeDUR manufactured by Colorado Roofing Products, LLC, which is located at: 3590 Himalaya Road, Aurora, CO 80011; Toll Free Tel: (844) 974-9196; Tel: (720) 974-9200; Fax: (720) 974-3193; Email: Info@CeDUR.com, Web:
www.cedur.com B. Substitutions: Not permitted
2.2 SYNTHETIC SHAKE SHINGLES
A. Lightweight, synthetic shakes with the appearance, color, texture, and thickness of natural wood shakes
1. Product: Multi-Width Shake as manufactured by CeDUR
2. Material: Engineered polymer formulated from 100 percent virgin polyurethanes to ensure high quality and consistency of raw materials. Use of recycled materials is not acceptable
3. Attributes:
a. Fire resistance: Class A (without the use of Class A rated underlayment’s) tested in accordance with ASTM E 108/UL 790 b.Impact resistance: Class 4 to withstand two drops of 2 inches diameter, 1.2 pounds steel ball dropped from 20 feet tested in accordance with UL 2218
c. Freeze-thaw resistance: No crazing, cracking, or other deleterious surface changes after one-month exposure with temperature cycled from -40 to +180 degrees F in 22 hours tested in accordance with International Code Council (ICC) – ES Acceptance Criteria AC07 Section 4.9
d. Accelerated weathering: Little change after 2,500 hours exposure to ultraviolet (UV) radiation, elevated temperature, moisture, and thermal shock tested in accordance with International Code Council (ICC) – ES Acceptance Criteria AC07 Section 4.9
e. Installed weight:
1. At 9 inches exposure: 188 pounds per square
2. At 10 inches exposure: 170 pounds per square
3. Profile: Solid polyurethane product manufactured in a rectangular shape with exposed to view upper surface and edges textured to resemble natural wood shake
4. Size: Shake
a. Thickness: Varies from 1/8 inch at top to ¾ inch at bottom b.Length: 23.75 inches
c. Variable widths: 5, 7, and 12 inches to create appearance of random sized natural wood shake
5. Starter Shingle: Provide 15 inches long by 15 inches wide
6. Markings: Form shingles with markings on upper surface to indicate nailing locations along with manufacturers quality markings
7. Color: Provide shingles in single color comparable to natural wood shakes, no color stabilizers allowed providing a natural aging process. Verify color with COR.
8. Shake Pattern: Provide shakes factory blended single color and widths to create installed appearance designated as follows
a. Walden by CeDUR
2.3 ACCESSORIES
A. Underlayment: Architecturally specified underlayment that meets ASTM D226 requirement.
B. Waterproof Sheet Membrane: Cold applied, self-adhering waterproof membrane composed of polyethylene film coated one side with rubberized asphalt adhesive
1. Thickness: 40 mils
2. Low temperature flexibility: Unaffected at minus 32 degrees F
SECTION 073110 - SHINGLES - CONTINUED
3. Minimum tensile strength: 250 psi
4. Minimum elongation: 250 percent
5. Permeance: 0.05 perms maximum
C. Flashing: Fabricate from sheet to profiles and dimensions indicated on Drawings and approved shop drawings and in accordance with general requirements specified in Section 07 60 00 – Flashing and Sheet Metal
1. Material: No less than 26 gauge galvanized steel
2. Linear components: Form in longest possible lengths with 8 feet as minimum
3. Counter Flashings: Extend 5 inches minimum up vertical surfaces and 5 inches minimum under shingles
4. Valley flashings: 24 inches minimum width and extending 11 inches minimum from valley center line
5. Fabricate eave flashings with bottom edge formed outward ¼ inch and hemmed to form drip
D. Fasteners: 3/8-inch ring shank flat head nails 1-3/4 inches long
1. Material: Stainless steel
2. Material: Hot-dipped galvanized
PART 3 - EXECUTION
3.1 EXAMINATION
A. Do not begin installation until substrates have been properly prepared B. If substrate preparation is the responsibility of another installer, notify COR of unsatisfactory preparation before proceeding
3.2 PREPERATION
A. Coordinate installation with provision of gutters and downspouts specified in Section 07 60 00 -Flashing and Sheet Metal B. Inspect roof framing and plywood or OSB substrate. Verify roof is complete, rigid, braced, and deck members are securely fastened. Ensure proper ventilation has been provided for roof space. Do not proceed with roofing until deficiencies are addressed C. Verify roof deck is clean, dry, and ready to receive synthetic shake shingles D. Remove dirt, loose fasteners, and other protrusions from roof surface
3.3 INSTALLATION GENERAL
A. Install self-adhered waterproof sheet membrane on the eaves. Cover the waterproof sheet membrane and the remaining portions of the roof as scheduled with the approved underlayment(s). Then install waterproof sheet membrane in valleys, along walls and around projections terminating on top of underlayment
3.4 UNDERLAYMENT INSTALLATION
A. Stripping Ply: A full sheet of self-adhered waterproof sheet membrane is required in all valleys. At least 18 inches (457 mm) shall be required on all gable ends, against walls, and around projections
1. In areas where the average daily temperature in January is 25 degrees F (-4 degrees C) or lower or where ice buildup is possible, install self-adhered waterproof sheet membrane from the bottom edge extending two feet (610 mm) above the exterior wall line on all eaves
B. Install waterproof sheet membrane over full roof area. Apply waterproof sheet membrane in fair weather at temperatures of 40 degrees F (4 degrees C) or higher. Adhere and attach as recommended by manufacturer of waterproof sheet membrane
1. Start underlayment installation at lower edge of roof. Install perpendicular to roof slope with 4 inches (102 mm) minimum side laps and 6 inches (152 mm) minimum end laps. Extend underlayment 4 inches (102 mm) minimum up vertical wall intersections
2. Do not leave underlayment membrane exposed for lengthy period of time. Exercise care not to puncture or tear underlayment barrier with subsequent roofing operations
3.5 FLASHING INSTALLATION
A. Install overhanging drip edge on eaves and gable ends and metal flashings at valleys, ridges, hips, roof curbs, penetrations, and intersections with vertical surfaces in accordance with Section 07 60 00 -Flashing and Sheet Metal B. Weather lap joints 2 inches minimum and seal with sealant as specified in Section 07 91 26 -Joint Fillers C. Secure in place with clips, nails, or other fasteners
3.6 INSTALLATION – GENERAL
A. Install synthetic shakes in accordance with manufacturer's instructions and approved shop drawings B. Accurately layout shingles. Ensure that edges are parallel and perpendicular to roof eaves C. Cutting: Layout work to avoid cutting shingles.
1. At gables and vertical intersections, vary combination of shingle widths and spacing of shingles to avoid cutting
2. If cutting is required, place shingle such that cut edge is not exposed
3. Use circular saw or straight edge and utility knife if cuts are necessary
3.7 SHAKE SHINGLE INSTALLATION
A. Install shingles in a rack or pyramid style from factory assembled bundles B. Exposure: Install shingles in staggered pattern with 9 inches exposure and bottom edges of adjacent shingles staggered 1 inch (25 mm) C. Spacing: Provide 1/4 - 3/8-inch gap between shingles to allow for expansion and contraction D. Stagger shingle joints in one course 1-1/2 inches minimum from joints in course below E. Eaves: Install row of starter shingles at eaves as base layer. Project eave shingles approximately 1 inch, 1/8 inch past overhanging drip edge, or as required to allow water to drain into gutter or off eave as indicated or required F. Gables: Project shingles approximately 3/4 inch beyond gable rakes or 1/8 inch past overhanging drip edge G. Ridges and Hips: After field shingle installation is complete, install preformed 5-inch CeDUR Hip/Ridge
1. Ridges: Use 5” CeDUR preformed Hip/Ridge shakes with 10” exposure. Start ridge shingles at leeward end. Face shingle laps away from prevailing wind
2. Hips: Use 5” CeDUR preformed Hip/Ridge shakes with 10” exposure. Start hip course at eave
H. Fastening: Attach each shingle to wood deck with 2 or 3 nails depending on shake size using hammer or pneumatic nail gun.
1. Place nails at locations indicated on shingles
2. Ensure good penetration but do not overdrive nail. Do not nail at angle. Ensure head is flush with shingle surface to avoid creating craters
3. At valleys do not nail shingles within 5 inches of valley center line
J. Snow Guards: Install snow guards in areas where snow fall is possible
3.8 FIELD QUALITY CONTROL
A. Inspect units as they are installed. Do not install cracked, broken, twisted, curled, or otherwise damaged units B. As work progresses, exercise care not to scratch or mar installed units. Units damaged during installation shall be immediately removed and discarded C. After approximately 200 units have been installed, inspect roof from ground. Verify proper layout and appearance. Repeat inspection every 200 shingles D. Visually inspect complete installation to ensure that it is weather tight
3.9 CLEANING AND PROTECTION
A. Remove excess materials and debris from finished surfaces and adjacent roof areas B. Do not allow work force on completed roof C. Protect installed products until completion of project D. Touch-up, repair or replace damaged products before Substantial Completion
END OF SECTION
SECTION 074293 - METAL SOFFIT PANELS
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes metal soffit panels.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product.
B. Shop Drawings: Include fabrication and installation layouts of metal panels; details of edge conditions, joints, panel profiles, corners, anchorages, attachment system, trim, flashings, closures, and accessories; and special details.
C. Samples: For each type of metal panel indicated.
1.3 INFORMATIONAL SUBMITTALS
A. Product test reports.
B. Warranties: Samples of special warranties.
1.4 CLOSEOUT SUBMITTALS
A. Maintenance data.
1.5 WARRANTY
A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of metal panel systems that fail in materials or workmanship within specified warranty period.
B. Special Warranty on Panel Finishes: Manufacturer's standard form in which manufacturer agrees to repair finish or replace metal panels that show evidence of deterioration of factory-applied finishes within specified warranty period.
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. Structural Performance: Provide metal panel systems capable of withstanding the effects of the following loads, based on testing according to ASTM E 1592:
1. Wind Loads: As indicated on Drawings.
2. Deflection Limits: For wind loads, no greater than 1/240 of the span.
B. Air Infiltration: Air leakage of not more than [0.3 L/s per sq. m (0.06 cfm/sq. ft.)] when tested according to ASTM E 283 at the following test-pressure difference:
1. Test-Pressure Difference: [75 Pa (1.57 lbf/sq. ft.)] [300 Pa (6.24 lbf/sq. ft.)].
C. Water Penetration under Static Pressure: No water penetration when tested according to ASTM E 331 at the following test-pressure difference:
1. Test-Pressure Difference: [137 Pa (2.86 lbf/sq. ft.)] [300 Pa (6.24 lbf/sq. ft.)].
D. Thermal Movements: Allow for thermal movements from ambient and surface temperature changes by preventing buckling, opening of joints, overstressing of components, failure of joint sealants, failure of connections, and other detrimental effects. Base calculations on surface temperatures of materials due to both solar heat gain and nighttime-sky heat loss.
1. Temperature Change (Range): [67 deg C (120 deg F), 100 deg C (180 deg F).
SECTION 074293 - METAL SOFFIT PANELS - CONTINUED
2.2 METAL SOFFIT PANELS
A. General: Provide metal soffit panels designed to be installed by lapping and interconnecting side edges of adjacent panels and mechanically attaching through panel to supports using concealed fasteners in side laps. Include accessories required for weathertight installation.
B. Metal Soffit Panels: Flush/reveal profile.
1. Finish: As selected by Archtiect from manufacturer’s full range of colors.
2. Sealant: Factory applied within interlocking joint.
C. Flush-Profile Metal Soffit Panels [Solid] [Perforated] panels formed with vertical panel edges and [intermediate stiffening ribs symmetrically spaced] [a flat pan] between panel edges; with flush joint between panels.
1. Manufacturers: Subject to compliance with requirements, [provide products by the following] [provide products by one of the following] [available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following]:
2.3 MISCELLANEOUS MATERIALS
A. Miscellaneous Metal Subframing and Furring: ASTM C 645, cold-formed, metallic-coated steel sheet, ASTM A 653/A 653M, G90 (Z275 hot-dip galvanized) coating designation or ASTM A 792/A 792M, Class AZM150 (Class AZ50) aluminum-zinc-alloy coating designation unless otherwise indicated. Provide manufacturer's standard sections as required for support and alignment of metal panel system.
B. Panel Accessories: Provide components required for a complete, weathertight panel system including trim, clips, flashings, sealants, gaskets, fillers, closure strips, and similar items. Match material and finish of metal panels unless otherwise indicated.
1. Closure Strips: Closed-cell, expanded, cellular, rubber or crosslinked, polyolefin-foam or closed-cell laminated polyethylene;
minimum 1-inch thick, flexible closure strips; cut or premolded to match metal panel profile. Provide closure strips where indicated or necessary to ensure weathertight construction.
C. Flashing and Trim: Provide flashing and trim formed from same material as metal panels as required to seal against weather and to provide finished appearance. Finish flashing and trim with same finish system as adjacent metal panels.
D. Panel Fasteners: Self-tapping screws designed to withstand design loads. Provide exposed fasteners with heads matching color of metal panels by means of plastic caps or factory-applied coating. Provide EPDM or PVC sealing washers for exposed fasteners.
E. Panel Sealants: Provide sealant types recommended by manufacturer that are compatible with panel materials, are nonstaining, and do not damage panel finish.
1. Sealant Tape: Pressure-sensitive, 100 percent solids, gray polyisobutylene compound sealant tape with release-paper backing; 1/8 inch thick.
2. Joint Sealant: ASTM C 920; as recommended in writing by metal panel manufacturer.
3. Butyl-Rubber-Based, Solvent-Release Sealant: ASTM C 1311.
2.4 FABRICATION
A. General: Fabricate and finish metal panels and accessories at the factory, by manufacturer's standard procedures and processes, as necessary to fulfill indicated performance requirements demonstrated by laboratory testing. Comply with indicated profiles and with dimensional and structural requirements.
B. On-Site Fabrication: Subject to compliance with requirements of this Section, metal panels may be fabricated on-site using UL-certified, portable roll-forming equipment if panels are of same profile and warranted by manufacturer to be equal to factory-formed panels. Fabricate according to equipment manufacturer's written instructions and to comply with details shown.
C. Provide panel profile, including major ribs and intermediate stiffening ribs, if any, for full length of panel.
D. Fabricate metal panel joints with factory-installed captive gaskets or separator strips that provide a weathertight seal and prevent metal-to-metal contact, and that minimize noise from movements.
E. Sheet Metal Flashing and Trim: Fabricate flashing and trim to comply with manufacturer's recommendations and recommendations in SMACNA's "Architectural Sheet Metal Manual" that apply to design, dimensions, metal, and other characteristics of item indicated.
2.5 FINISHES
A. Panels and Accessories:
1. Two-Coat Fluoropolymer: AAMA 621, AAMA 620. Fluoropolymer finish containing not less than 70 percent PVDF resin by weight in color coat. Prepare, pretreat, and apply coating to exposed metal surfaces to comply with coating and resin manufacturers' written instructions.
3. Siliconized Polyester: Epoxy primer and silicone-modified, polyester-enamel topcoat; with a dry film thickness of not less than
0.2 mil for primer and 0.8 mil for topcoat.
4. Concealed Finish: White or light-colored acrylic or polyester backer finish.
PART 3 - EXECUTION
3.1 PREPARATION
A. Miscellaneous Supports: Install subframing, furring, and other miscellaneous panel support members and anchorages according to ASTM C 754 and metal panel manufacturer's written recommendations.
1. Soffit Framing: Clip furring channels to supports as required to comply with requirements for assemblies indicated.
3.2 METAL PANEL INSTALLATION
A. Metal Soffit Panels: Fasten metal panels to supports with fasteners at each lapped joint at location and spacing recommended by manufacturer.
1. Apply panels and associated items true to line for neat and weathertight enclosure.
2. Provide metal-backed washers under heads of exposed fasteners bearing on weather side of metal panels.
3. Locate and space exposed fasteners in uniform vertical and horizontal alignment. Use proper tools to obtain controlled uniform compression for positive seal without rupture of washer.
4. Install screw fasteners with power tools having controlled torque adjusted to compress washer tightly without damage to washer, screw threads, or panels. Install screws in predrilled holes.
B. Accessory Installation: Install accessories with positive anchorage to building and weathertight mounting, and provide for thermal expansion. Coordinate installation with flashings and other components.
C. Flashing and Trim: Comply with performance requirements, manufacturer's written installation instructions, and SMACNA's "Architectural Sheet Metal Manual." Provide concealed fasteners where possible, and set units true to line and level as indicated.
Install work with laps, joints, and seams that are permanently watertight.
3.3 CLEANING
A. Remove temporary protective coverings and strippable films, if any, as metal panels are installed unless otherwise indicated in manufacturer's written installation instructions. On completion of metal panel installation, clean finished surfaces as recommended by metal panel manufacturer. Maintain in a clean condition during construction.
END OF SECTION
SECTION 074643.13 - ENGINEERED WOOD SIDING
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Engineered wood siding.
a. Lap siding.
2. Accessories.
B. Related Requirements:
1. Section 072726 "Fluid-Applied Membrane Air Barriers" for vapor-retarding and vapor-permeable fluid-applied air barriers.
1.2 DEFINITIONS
A. Treated Engineered Wood: Engineered wood products manufactured for exterior use treated with manufacturer's proprietary process to resist fungal decay and termite damage.
1.3 COORDINATION
A. Coordinate engineered wood siding installation with flashings, trim, and construction of other adjoining work to ensure proper sequencing, construction progress, and to provide a leakproof, secure, and noncorrosive installation.
1.4 PREINSTALLATION MEETINGS
A. Preinstallation Conference: Conduct conference at Homestead National Monument of America, 8523 NE-4, Beatrice, Ne 68310.
1.5 INFORMATIONAL SUBMITTALS
A. Qualification Data: For engineered wood siding Installer.
B. Product Certificates: For each type of enginereed wood siding.
C. Research/Evaluation Reports: For each type of enginereered wood siding required, from ICC-ES.
D. Sample Warranty: For special warranty.
1.6 CLOSEOUT SUBMITTALS
A. Maintenance Data: For each type of product, including related accessories, to include in maintenance manuals.
1.7 MAINTENANCE MATERIAL SUBMITTALS
A. Furnish extra materials that match products installed and that are packaged with protective covering for storage and identified with labels describing contents.
1. Furnish full lengths of engineered wood siding including related accessories, in a quantity equal to 2 percent of amount installed.
1.8 QUALITY ASSURANCE
A. Installer Qualifications: Installers trained by siding manufacturer.
B. Panel to comply with HUD-UM-40c - HUD Building Product Standards and Certification Program for Plywood and Other Performance Rated Wood-Based Structural-Use Panels.
SECTION 071326 - SELF ADHERING WATERPROOFING MEMBRANE
PART 1 - GENERAL
1.01 SECTION INCLUDES
A. Surface preparation.
B. Application of rolled, self-adhering waterproofing membrane system.
1.02 SUBMITTALS
A Submit manufacturer's product data and application instructions.
PART 2 - PRODUCTS
2.01 MANUFACTURER
A. W.R. MEADOWS, Inc.,. HYPERLINK "http://www.wrmeadows.com" www.wrmeadows.com.
B. Or equal as approved by Contracting Officer or Architect.
2.02 MATERIALS
A. Rolled, Self-Adhering Waterproofing Membrane: Polymeric waterproofing membrane protected by release paper on cross-laminated polyethylene carrier film with exposed polymeric membrane strips on both sides protected by pull-off release strips.
1. Performance Based Specification: Waterproofing membrane shall have the following characteristics:
a. Compliance: AREMA Specification Chapter 29 - Waterproofing.
b. Thickness:
1) Carrier Film: 4 mils.
2) Polymeric Membrane: 56 mils.
c. Tensile Strength, ASTM D412, Die C:
1) Carrier Film: 5,900 psi minimum.
2) Polymeric Membrane: 460 psi minimum.
d. Elongation, ASTM D412, Die C: Polymeric Membrane: 971 % minimum.
e. Peel Adhesion, ASTM D903: 11.8 lbf/in.
f. Lap Adhesion, ASTM D1876: 8.62 lbf/in.
g. Water Vapor Permeability, ASTM E96, Method B: 0.036 perms.
h. Water Absorption, ASTM D570: 0.1 percent, 72 hours maximum.
i. Resistance to Hydrostatic Head: Equivalent to 230.9 feet of water.
j. Puncture Resistance, ASTM E154: 48.2 lbf .
k. Exposure to Fungi, Soil Test: Pass, 16 weeks.
l. Color:
1) Carrier Film: White.
2) Polymeric Membrane: Black.
2.03 ACCESSORIES
A. Surface Conditioner:
1. Temperatures Above 40oF (4oC): Mel-Prime Water Base Primer.
2. Temperatures Above 0oF (-18oC): Mel-Prime VOC Compliant Solvent Base Primer or Standard Solvent Base Primer.
B. Pointing Mastic: POINTING MASTIC.
C. Corner Tape: DETAIL STRIP.
PART 3 - EXECUTION
3.01 EXAMINATION
A. Examine surfaces to receive self-adhering membrane. Notify Architect if surfaces are not acceptable. Do not begin surface preparation or application until unacceptable conditions have been corrected.
3.02 SURFACE PREPARATION
A. Protect adjacent surfaces not designated to receive waterproofing.
B. Seal all terminations with pointing mastic.
C. Per manufactures recommendations
3.03 APPLICATION
A. Horizontal Application
1. Apply waterproofing membrane system in accordance with manufacturer's instructions.
B. Vertical Application
1. Apply waterproofing membrane system in accordance with manufacturer's instructions.
3.04 PROTECTION
A. Protect membrane on vertical and horizontal applications with immediate application of waterproofing protection course, rolled matrix drainage board.
B. Backfill immediately using care to avoid damaging waterproofing membrane system.
END OF SECTION
SECTION 072726 - FLUID-APPLIED MEMBRANE AIR BARRIERS
c. Ultimate Elongation: Minimum 250 percent; ASTM D 412, Die C.
d. Adhesion to Substrate: Minimum 16 lbf/sq. in. when tested according to ASTM D 4541.
e. Fire Propagation Characteristics: Passes NFPA 285 testing as part of an approved assembly if applicable.
f. UV Resistance: Can be exposed to sunlight for 180 days according to manufacturer's written instructions.
2.3 ACCESSORY MATERIALS
A. Requirement: Provide primers, transition strips, termination strips, joint reinforcing fabric and strips, joint sealants, counterflashing strips, flashing sheets and metal termination bars, termination mastic, substrate patching materials, adhesives, tapes, foam sealants, lap sealants, and other accessory materials that are recommended in writing by air-barrier manufacturer to produce a complete air-barrier assembly and that are compatible with primary air-barrier material and adjacent construction to which they may seal.
PART 3 - EXECUTION
3.1 SURFACE PREPARATION
A. Clean, prepare, treat, fill, and seal substrate and joints and cracks in substrate according to manufacturer's written instructions and details. Provide clean, dust-free, and dry substrate for air-barrier application.
B. Mask off adjoining surfaces not covered by air barrier to prevent spillage and overspray affecting other construction.
C. Remove fins, ridges and other projections and fill honeycomb, aggregate pockets, holes, and other voids in concrete with substrate-patching material.
D. At changes in substrate plane, apply sealant or termination mastic beads at sharp corners and edges to form a smooth transition from one plane to another.
E. Bridge isolation joints, expansion joints, and discontinuous wall-to-wall, deck-to-wall, and deck-to-deck joints with air-barrier accessory material that accommodates joint movement according to manufacturer's written instructions and details.
3.2 INSTALLATION
A. Install materials according to air-barrier manufacturer's written instructions and details to form a seal with adjacent construction and ensure continuity of air and water barrier.
1. Coordinate the installation of air barrier with installation of roofing membrane and base flashing to ensure continuity of air barrier with roofing membrane.
2. Install transition strip on roofing membrane or base flashing so that a minimum of 3 inches of coverage is achieved over each substrate.
3. Unless manufacturer recommends in writing against priming, apply primer to substrates at required rate and allow it to dry.
4. Apply primer to substrates at required rate and allow it to dry. Limit priming to areas that will be covered by air-barrier material on same day. Reprime areas exposed for more than 24 hours.
B. Connect and seal exterior wall air-barrier material continuously to roofing-membrane air barrier, concrete below-grade structures, floor-to-floor construction, exterior glazing and window systems, glazed curtain-wall systems, storefront systems, exterior louvers, exterior door framing, and other construction used in exterior wall openings, using accessory materials.
C. Wall Openings: Prime concealed, perimeter frame surfaces of windows, curtain walls, storefronts, and doors. Apply transition strip so that a minimum of 3 inches of coverage is achieved over each substrate. Maintain 3 inches of full contact over firm bearing to perimeter frames, with not less than 1 inch of full contact.
D. Repair punctures, voids, and deficient lapped seams in strips and transition strips. Slit and flatten fishmouths and blisters.
Patch with transition strips extending 6 inches beyond repaired areas in strip direction.
E. Medium-Build Air Barriers: Apply continuous unbroken air-barrier material to substrates according to the following thickness.
Apply an increased thickness of air-barrier material in full contact around protrusions such as masonry ties.
1. Vapor-Permeable, Medium-Build Air Barrier: Total dry film thickness as recommended in writing by manufacturer to comply with performance requirements, applied in one or more equal coats. Apply additional material as needed to achieve void- and pinhole-free surface, but do not exceed thickness on which required vapor permeability is based.
F. Do not cover air barrier until it has been tested and inspected by testing agency.
G. Correct deficiencies in or remove air barrier that does not comply with requirements; repair substrates and reapply air-barrier components.
3.3 CLEANING AND PROTECTION
A. Protect air-barrier system from damage during application and remainder of construction period, according to manufacturer's written instructions.
B. Remove masking materials after installation.
END OF SECTION
SECTION 072726 - FLUID-APPLIED MEMBRANE AIR BARRIERS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Vapor-permeable, fluid-applied air barriers.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product.
1.3 QUALITY ASSURANCE
A. Installer Qualifications: An entity that employs installers and supervisors who are trained and approved by manufacturer.
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. Air-Barrier Performance: Air-barrier assembly and seals with adjacent construction shall be capable of performing as a continuous air barrier and as a liquid-water drainage plane flashed to discharge to the exterior incidental condensation or water penetration. Air-barrier assemblies shall be capable of accommodating substrate movement and of sealing substrate expansion and control joints, construction material changes, penetrations, and transitions at perimeter conditions without deterioration and air leakage exceeding specified limits.
2.2 MEDIUM-BUILD AIR BARRIERS, VAPOR PERMEABLE
A. Medium-Build, Vapor-Permeable Air Barrier: Synthetic polymer material with an installed dry film thickness, according to manufacturer's written instructions, of 17 to 30 mils over smooth, void-free substrates.
1. Manufacturers: Subject to compliance with requirements, provide…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .