This document appears to be a set of drawings associated with Solicitation Number 140P2024R0084, which is for the construction of a fire station at the Big Cypress National Preserve Headquarters Complex. The solicitation is being issued by the Department of the Interior National Park Service National Office, a civilian federal agency. The drawings provide detailed information about the requirements for the fire station construction project, including specifications for the building layout, infrastructure, and other design elements. This document does not contain information about the overall solicitation details, such as response dates, award information, pricing terms, or set-asides. It is a technical attachment focused on the drawings and design requirements for the fire station construction.
View the file
Other files for this federal contract opportunity
Show all 50
BICY 229154 has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUILDING INFORMATION AND LIMITATIONS
BUILDING OCCUPANCY CLASSIFICATION: BUSINESS (GROUP B)
CONSTRUCTION TYPE: ll-B
SPRINKLERED: N
ALLOWABLE BUILDING HEIGHT: 3 STORIES, 60'
ACTUAL BUILDING HEIGHT: 1 STORIES,<25'
ALLOWABLE BUILDING AREA (PER STORY): 36,000 GSF
ACTUAL BUILDING AREA (PER STORY): 5,142 GSF
TOTAL OCCUPANT LOAD: 42
PROJECT LOCATION
PARK BOUNDARY
LOCATION MAP
PROJECT LOCATION
PROJECT INFORMATION
INDEX OF DRAWINGS
REV SHEET
SUB
SHEET TITLE OF SHEET
1 G0.00 COVER
2 G0.01 GENERAL NOTES, SYMBOL LEGEND AND ABBREVIATIONS
3 G0.02 TYPICAL TOILET ROOMS AND MOUNTING HEIGHTS
4 G0.03 CODE COMPLIANCE
5 G0.04 CODE COMPLIANCE
6 G1.01 LEVEL 1 LIFE SAFETY PLAN
7 C0.01 GENERAL NOTES AND DETAILS
8 C0.02 LEGEND
9 C0.03 STORMWATER POLLUTION PREVENTION NOTES
10 C1.01 STORMWATER POLLUTION PREVENTION PLAN
11 C1.02 DEMOLITION AND TREE PROTECTION PLAN
12 C1.03 MASTER PLANNING PLAN
13 C1.04 DETAILED HORIZONTAL CONTROL AND SITE PLAN
14 C1.05 DETAILED GRADING, DRAINAGE, AND UTILITY PLAN
15 C1.06 DETAILED GRADING, DRAINAGE, AND UTILITY PLAN
16 A1.01 ARCHITECTURAL SITE PLAN
17 A1.02 LEVEL 1 FLOOR PLAN
18 A1.03 LEVEL 1 ACCESSIBILITY PLAN
19 A1.04 LEVEL 1 PARTITION PLAN
20 A1.05 LEVEL 1 CEILING PLAN
21 A1.06 ROOF PLAN
22 A1.07 LEVEL 1 FINISH PLAN
23 A2.01 EXTERIOR ELEVATIONS
24 A3.01 BUILDING SECTIONS
25 A3.02 BUILDING SECTIONS
26 A3.03 WALL SECTIONS
27 A4.01 ENLARGED ARCHITECTURAL SITE PLAN - PROJECT SITE
28 A4.02 ENLARGED INTERIOR VIEWS - FLOOR PLAN
29 A4.03 ENLARGED INTERIOR VIEWS - ELEVATIONS
30 A5.01 ROOF DETAILS
31 A5.02 ROOF DETAILS
32 A5.03 ROOF DETAILS
33 A5.04 ROOF DETAILS
34 A5.05 ROOF DETAILS
35 A5.06 ROOF DETAILS
36 A5.07 EXTERIOR DETAILS
37 A5.08 EXTERIOR DETAILS
38 A5.09 EXTERIOR DETAILS
39 A5.10 EXTERIOR DETAILS
40 A5.11 PARTITION DETAILS
41 A5.12 INTERIOR AND FINISH DETAILS
42 A5.13 INTERIOR CASEWORK DETAILS
43 A5.14 OPENING DETAILS
44 A5.15 OPENING DETAILS
45 A5.16 OPENING DETAILS
46 A5.17 OPENING DETAILS
47 A5.18 OPENING DETAILS
48 A5.19 OPENING DETAILS
49 A6.01 PARTITION TYPES
50 A6.02 OPENING TYPES AND SCHEDULE
51 A9.01 EXTERIOR PERSPECTIVE VIEW
TITLE OF DRAWING: DRAWING NO.
PMIS/PKG NO.
OF
A/E
PRIME/ARCH
SHEET
MECHANICA
HENRY
ADAMS, LLC.
BALTIMORE, MD
WALKER
ARCHITECTS, INC.
GAINESVILLE, FL
UNITED STATES
DEPARTMENT OF THE INTERIOR
LOCATION WITHIN PARK
NAME OF THE PARK
REGION STATECOUNTY
NATIONAL PARK SERVICE
DENVER SERVICE CENTER
QUALITY DESIGN CERTIFICATION
PREPARED IN ACCORDANCE WITH DESIGN
DEVELOPMENT (TITLE I) _________________________
VARIANCE FROM DESIGN DEVELOPMENT (TITLE I)
APPROVED BY SUPERINTENDENT ON ______________
CONSTRUCTION DRAWING NOT PRECEDED
BY DESIGN DEVELOPMENT (TITLE I)
PROJECT MANAGER DATE
DRAWING NO.
DATE
CIVIL
PLUMBIN
HENRY
ADAMS, LLC.
BALTIMORE, MD
CHW, INC.
ALACHUA, FL
ELECTRICAL
STRUCTURAL
AES, INC.
JACKSONVILLE,F
HENRY
ADAMS, LLC.
BALTIMORE, MD
/2
/2
:4
:0
P
M NEW FIRE OPERATIONS CENTER
BIG CYPRESS NATIONAL PRESERVE
229154
BICY HEADQUARTERS
DESIGN DEVELOPMENT
SOUTH-EAST COLLIER FLORIDA
REV SHEET
SUB
SHEET TITLE OF SHEET
52 E0.01 ELECTRICAL COVER SHEET
53 E0.02 ELECTRICAL NOTES AND CONVENTIONS
54 E0.03 ELECTRICAL SITE PLAN
55 E1.01 LEVEL 1 LIGHTING PLAN
56 E2.01 LEVEL 1 POWER PLAN
57 E2.02 ROOF POWER AND LIGHTING PROTECTION PLAN
58 E4.01 ELECTRICAL PART PLANS
59 E5.01 ELECTRICAL DETAILS
60 E5.02 ELECTRICAL DETAILS
61 E5.03 ELECTRICAL DETAILS
62 E5.04 ELECTRICAL DETAILS
63 E6.01 ELECTRICAL ONE-LINE DIAGRAM
64 E6.02 TELECOMMUNCATIONS RISER DIAGRAM
65 E6.03 ELECTRICAL GROUNDING AND BONDING DIAGRAM
66 E7.01 LIGHTING CONTROL DIAGRAMS
67 E7.02 LIGHTING CONTROL SCHEDULE AND MATRIX
68 E8.01 LUMINAIRE SCHEDULE
69 E8.02 ELECTRICAL EQUIPMENT SCHEDULES
70 E8.03 PANELBOARD SCHEDULES
71 M0.01 MECHANICAL COVER SHEET
72 M0.02 MECHANICAL SITE PLAN
73 M1.01 LEVEL 1 DUCTWORK PLAN
74 M2.01 LEVEL 1 MECHANICAL PIPING PLAN
75 M4.01 MECHANICAL SECTIONS
76 M5.01 MECHANICAL DETAILS
77 M6.01 AUTOMATIC TEMPERATURE CONTROLS
78 M7.01 MECHANICAL SCHEDULES
79 P0.01 PLUMBING COVER SHEET
80 P0.02 PLUMBING SITE PLAN
81 P1.00 FOUNDATION PLUMBING PLAN
82 P1.01 LEVEL 1 PLUMBING PLAN
83 P1.02 ROOF PLUMBING PLAN
84 P3.01 PLUMBING PART PLANS
85 P3.02 PLUMBING PART PLANS
86 P3.03 PLUMBING PART PLANS
87 P5.01 PLUMBING DETAILS
88 P6.01 DOMESTIC WATER RISER DIAGRAMS
89 P6.02 SANITARY RISER DIAGRAMS
90 P6.03 CONDENSATE RISER DIAGRAMS
91 P7.01 PLUMBING SCHEDULES
97 S3.03 SECTIONS
92 S0.01 GENERAL NOTES
93 S1.01 FOUNDATION PLAN
94 S1.02 GENERATOR PAD AND FIRE SUPPRESSION TANK PLANS
95 S3.01 SECTIONS
96 S3.02 SECTIONS
98 S5.01 TYPICAL DETAILS
NTS
N
MARK REVISION DATE INITIAL
NJones Image
WALL SECTION
DETAIL/ SECTION
NUMBER
SHEET NUMBER
BUILDING SECTION
EXTERIOR ELEVATION
SHEET NUMBER
ELEVATION NUMBER
INTERIOR ELEVATION
SHEET NUMBER
ELEVATION NUMBER
LARGE SCALE BLOWUP
OF PLAN OR DETAIL
PLAN OR DETAIL
NUMBER
SHEET NUMBER
LEVEL REFERENCE
LEVEL DESCRIPTION
LEVEL ELEVATION
NEW
STRUCTURAL GRID
GRID REFERENCE
GRID LINE
EXISTING
STRUCTURAL GRID
EXISTING GRID
REFERENCE
EXISTING GRID LINE
MATCH LINE 1 / A0103
1 / A0102
SHEET NUMBER
SHEET NUMBER
MATCH LINE
REVISION
CLOUDED AREA
OF REVISION
NORTH ARROW
SIMILAR INDICATION
DETAIL SECTION
DETAIL/ SECTION
NUMBER
SHEET NUMBER
A101
DETAIL NUMBER
SHEET NUMBER
N
Level 01
100' - 0"
A101
SIM
A101
A101
A101
A201
01 / A301
PARTITION PARTITION TYPE
DOOR
ASSEMBLY
EXTERIOR
GLAZED
OPENINGS
ROOM NAME
AND NUMBER
ROOM NAME
ROOM NUMBER
KEYNOTE
DEMOLITION
CONSTRUCTION
STOREFRONT
OPENINGS
OPENING TYPE
FURNITURE, FIXTURES &
EQUIPMENT
EQUIPMENT IDENTIFIER
DOOR NUMBER
OPENING TYPE
D01
M8G
1t
1t
1t
ROOM NAME
ROOM FINISHES TAG
ROOM NAME
ROOM NUMBER
FLOOR:
BASE:
WALL:
CONFERENCE
FLOORING
BASE
WALL
150 SF
APPROXIMATE ROOM AREA
ROOM FINISHES
.0
NEW CONSTRUCTION
AC AIR CONDITIONING
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
ARCH ARCHITECT, ARCHITECTURAL
AUTO AUTOMATIC
BLDG BUILDING
BRG BEARING
CFCI CONTRACTOR FURNISHED
CONTRACTOR INSTALLED
CFCM COLD FORMED METAL FRAMING
CIP CAST-IN-PLACE (CONCRETE)
CJ CONTROL JOINT
CL CENTERLINE
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CORR CORRIDOR
DEMO DEMOLISH, DEMOLITION
DEPT DEPARTMENT
DIA DIAMETER
DIM DIMENSION
DN DOWN
EA EACH
EJ EXPANSION JOINT
ELEC ELECTRIC, ELECTRICAL
EOS EDGE OF SLAB
EQ EQUAL
EQUIP EQUIPMENT
EXP EXPANSION
EXT EXTERIOR
EWC ELECTRIC WATER COOLER
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FHC FIRE HOSE CABINET
FT FOOT/FEET
FURN FURNISH, FURNISHED, FURNISHINGS
GA GAUGE, GAGE
GWB GYPSUM WALL BOARD
HSS HOLLOW STRUCTURAL SECTION
HVAC HEATING-VENTILATING-AIR CONDITIONING
ID INSIDE DIAMETER
INT INTERIOR
LAV LAVATORY
LWIC LIGHTWEIGHT INSULATING CONCRETE
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER, MANUFACTURED
MIN MINIMUM
MISC MISCELLANEOUS
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OFOI OWNER FURNISHED OWNER INSTALLED
OPP OPPOSITE
ORD OVERFLOW ROOF DRAIN
PCF POUNDS PER CUBIC FOOT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
QTY QUANTITY
R RADIUS
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REF REFRIGERATOR
REV REVISE (ISION)
RO ROUGH OPENING
RTU ROOF TOP UNIT
SF SQUARE FOOT, FEET
SIM SIMILAR
SPEC SPECIFY, SPECIFICATION
SS STAINLESS STEEL
STC SOUND TRANSMISSION CLASS
STRUC STRUCTURE, STRUCTURAL
TBD TO BE DETERMINED
TEMP TEMPORARY
TOS TOP OF STEEL
TOW TOP OF WALL
TYP TYPICAL
T&G TONGUE AND GROOVE
UC UNDERCOUNTER
UOI UNLESS OTHERWISE INDICATED
VIF VERIFY IN FIELD
VTR VENT THROUGH ROOF
WD WOOD
WP WEATHERPROOF
1. DO NOT SCALE DRAWINGS. RELY ON THE NUMERIC DIMENSIONS SHOWN FOR
MEASUREMENT. IF DIMENSIONS ARE IN QUESTION, OBTAIN CLARIFICATION FROM THE
ARCHITECT
2. REVIEW AND FIELD VERIFY ALL DIMENSIONS AND CONDITIONS BEFORE
CONSTRUCTION, FABRICATION, OR INSTALLATION OF ANY INSTANCE. NOTIFY THE
ARCHITECT WHEN CONDITIONS VARY FROM THE PROJECT DRAWINGS.
3. DETAILED DRAWINGS AND LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER
SMALLER SCALE DRAWINGS.
4. UNLESS INDICATED OTHERWISE, PLAN DIMENSIONS ARE TAKEN FROM CENTERLINE OF
STRUCTURE, FACE OF CONCRETE OR FACE OF STUD. PLAN DIMENSIONS TO PLUMBING
FIXTURES AND ACCESSORIES ARE TAKEN FROM FINISHED FACE OF WALL.
5. DOORS NOT OTHERWISE DIMENSIONED SHALL BE 8" FROM ADJACENT CMU OR
CONCRETE WALL TO ROUGH DOOR OPENING, AND 5" FROM FACE OF ADJACENT STUD
WALL TO ROUGH DOOR OPENING.
6. FINISH FLOOR ELEVATIONS ARE TO TOP OF CONCRETE SLAB UNLESS OTHERWISE
INDICATED.
7. PROVIDE BACKING/BLOCKING FOR THE ATTACHMENT OF MISCELLANEOUS ITEMS
INCLUDING, BUT NOT LIMITED TO: TOILET ACCESSORIES, DOOR HARDWARE,
ELECTRICAL DEVICES, GRAB BARS, CASEWORK, AND MILLWORK. SEE PARTITION
DETAILS SHEET.
8. FOR CONSTRUCTION DETAILS NOT SHOWN, USE THE PRODUCT MANUFACTURER'S
WRITTEN INSTALLATION INSTRUCTIONS AND STANDARD DETAILS, IN STRICT
ACCORDANCE WITH THE PROJECT SPECIFICATION REQUIREMENTS AND DESIGN
INTENT.
9. PROVIDE ACCESS DOORS OF APPROPRIATE SIZE, TYPE AND FIRE RATING FOR ALL
CONCEALED ITEMS THAT REQUIRE ADJUSTMENT, MAINTENANCE, MONITORING, ETC.
COORDINATE LOCATIONS WITH ARCHITECT.
10. ENCLOSE DUCTS, PIPES, CONDUITS, AND OTHER UTILITIES IN FINISHED SPACES TO
MATCH ADJACENT FINISHES UNLESS INDICATED OTHERWISE. (FOR EXAMPLE DO NOT
LEAVE CONDUIT EXPOSED IN A ROOM THAT IS NOT A MECHANICAL ROOM, PROVIDE A
GYPSUM BOARD PARTITION ENCLOSURE TO CONCEAL.)
11. DO NOT SUPPORT/HANG ITEMS FROM METAL ROOF DECK, SUPPORT FROM PRE
ENGINEERED METAL BUILDING PURLINGS. COORDINATE WITH MANUFACTURER TO
PROVIDE ROOF PURLIN DESIGN THAT SUPPORTS PULL LOADS COMING FROM
SYSTEMS BELOW DECK.
12. PROVIDE TERMITE TREATMENT UNDER NEW CONCRETE SLABS ON GRADE.
GOVERNMENT PROVIDED AND
INSTALLED FURNITURE OR EQUIPMENT
(HALFTONE/HALFTONE LINES)
CONTRACTOR PROVIDED AND
INSTALLED FURNITURE OR EQUIPMENT
(SOLID LINES)
REFERENCE SYMBOLS (ALL DISCIPLINES) REFERENCE SYMBOLS (ARCHITECTURAL)
TYPICAL PHASING GRAPHICS
ABBREVIATIONS
DESIGNED:
CADD:
TECH REVIEW:
DATE:
SUB SHEET NO: TITLE OF SHEET: DRAWING NO.
PMIS/PKG NO.
OF
A/E FIRM:
PRIME:
SHEET
SUB:
REFERENCE
COVER SHEET
WALKER
ARCHITECTS,
GAINESVILLE, FL
/2
/2
:4
:0
P
M GENERAL
AI
4/29/2024
G0.01TW
GENERAL NOTES, SYMBOL
LEGEND AND ABBREVIATIONS
229154
NPS FIRE OPERATIONS CENTER AT
BIG CYPRESS NATIONAL PRESERVE
GENERAL NOTES
FURNITURE EQUIPMENT GRAPHICS
PULL
SHELF/ MOP
HOLDER
SERVICE
FAUCET AND
CONTROLS
MOP BASIN
JANITOR CLOSET
M A
X
M
IN
WATER
CLOSET
PROVIDE METAL
BLOCKING AS
REQUIRED
GRAB BAR
SINK/
LAVATORY
MIRROR AT
SINK/LAVATORY
T O
B O
T T
O M
O F
R
E F
L E
C T
IV
S
U R
F A
C E
TOILET PAPER
DISPENSER
M
IN
SEAT COVER
DISPENSER
M A
X
SOAP OR
HAND SANITIZER
DISPENSER
M A
X
PAPER TOWEL
DISPENSER
BABY CHANGE
STATION
PLUMBING FIXTURES & ACCESSORIES NOTES:
1. VERIFY ALL PLACEMENT WITH PLAN, ELEVATION, AND
CURRENT CODES.
2. SEE SPECIFICATIONS FOR ACCESSORY MANUFACTURER
AND MODEL.
3. INSULATE ALL EXPOSED PIPES.
4. COORDINATE ALL FIXTURES WITH PLUMBING DRAWINGS
AND SPECIFICATIONS.
5. PROVIDE AND INSTALL NON-COMBUSTIBLE INTERNAL WALL
BLOCKING AS REQUIRED TO ACHIEVE SECURE ATTACHMENT
MEETING STRENGTH REQUIREMENTS OF APPLICABLE
CODES FOR ALL WALL MOUNTED ACCESSORIES.
6. ORIENT FLUSH LEVER AT TOILET TO THE OPEN SIDE OF THE
ROOM.
M
IN
SANITARY NAPKIN
DISPOSAL
T O
D
IS
P E
N S
E R
O U
T L
T
(I N
S T
A L L A
T
IO
N
M
IN
A
B O
V E
G R
A B
B A
R
COAT
HOOK
S
T A
N D
A R
D
A
C C
E S
S
IB
L E
T O
T
P
F
B O
W L
T O
T O
P O
F R
E F
L E
C T
IV
S
R
F A
C E
FIRE EXTINGUISHER
IN RECESSED
CABINET
M
A X
T O
S P
O
T L E
T
T O
S P
O
T L E
T
DRINKING FOUNTAINS
WITH BOTTLE FILLER
M
IN
M A
X
CANE
APRON
M
IN
FBC-A 2020 604.4 FBC-A 2020 609.4 LAV HEIGHT: FBC-A 2020 606.3
KNEE CLEARANCE: FBC-A 2020 306.3
TOE CLEARANCE: FBC-A 2020 306.2
C L E
A R
M
IN
11" MIN
6" MIN
8" MIN
FBC-A 2020 603.3 DISPENSER HEIGHT: FBC-A 2020 606.3
SPACING FROM GRAB BAR: FBC-A 2020 609.3
OBSTRUCTED
REACH RANGE:
FBC-A 2020 308.2.2
FBC-A 2020 603.4
UNOBSTRUCTED
REACH RANGE:
FBC-A 2020 308.3.1
OBSTRUCTED
REACH RANGE:
FBC-A 2020 308.2.2
OBSTRUCTED
REACH RANGE:
FBC-A 2020 308.2.2
SPOUT HEIGHT: FBC-A 2020 602.4
KNEE CLEARANCE: FBC-A 2020 306.3
TOE CLEARANCE: FBC-A 2020 306.2
VERTICAL CLEARANCE: FBC-A 2020 307.4
2"
FBC-B 2020 906.9.1
9"
EQ EQ
SHOWER AND
CONTROLS
FBC-A 2020 608.5.2
N O
T A
T S
IN
K
M A
X
WC1
ACCESSIBLE
WATER CLOSET
1'-6"
1'-0" 2'-0"
60" WIDE x 56"
DEEP CLEAR
FLOOR SPACE
30" WIDE x 48"
DEEP CLEAR
FLOOR SPACE
ACCESSIBLE
SINK
1'-6" HOLD
48" WIDE x 30"
DEEP CLEAR
FLOOR SPACE
ACCESSIBLE
SINK
GENERIC SINGLE OR DOUBLE SINK
SHOWN HERE IN COUNTERTOP. SEE
PLUMBING FIXTURE SCHEDULE FOR
ACTUAL FIXTURE TYPE.
S1 S2
GB36
GB48
TPD
IN WOMEN'S
TOILET ONLY
SD
PTD
LOCATE
ACCESSORIES
IN FIELD WITH
OWNER PTD
SD
LOCATE
ACCESSORIES
IN FIELD WITH
OWNER
CH COAT HOOK
GBxx GRAB BAR (xx INDICATES LENGTH)
MIR MIRROR
PTD PAPER TOWEL DISPENSER
SCD SEAT COVER DISPENSER
SD SOAP DISPENSER
SHRS SHOWER SEAT
TPD TOILET PAPER DISPENSER
TOILET ACCESSORIES ABBREVIATIONS:
SCD
MIR
TLT1
ACCESSIBLE
TOILET ROOM
SEE PLANS
7'-6" MIN
REFER TO DRAWING S1 THIS
SHEET FOR ADDITIONAL
SINK DETAILS AND RELATED
TOILET ACCESSORIES
S1WC1
REFER TO DRAWING WC1 THIS
SHEET FOR ADDITIONAL
WATER CLOSET AND RELATED
TOILET ACCESSORIES DETAILS
NOTE THAT THIS IS A GENERIC
LAYOUT SHOWING FIXTURES,
ACCESSORIES, AND POSSIBLE
DOOR LOCATIONS. SEE FLOOR
PLANS FOR ACTUAL PLAN
LAYOUT WITH DIMENSIONS.
TOILET TYPE TLT1 - SEE
FLOOR PLANS FOR TOILET
TYPE DESIGNATIONS ON
DRAWING.
CLEAR FLOOR SPACE
REQUIREMENTS
SHOWN DASHED
TOILET ROOM AND ACCESSORY NOTES:
1. ENLARGED PLANS INDICATE DIMENSIONS, TOILET
ACCESSORY LOCATIONS, AND REQUIRED CLEARANCES TO
BE MAINTAINED.
2. ENLARGED TOILET ROOM LAYOUT (TLT1) AND SINK TYPES
(S1, S2) ARE KEYED ONTO ENLARGED FLOOR PLANS.
3. REFER TO ENLARGED FLOOR PLAN SHEETS FOR EXACT
TOILET ROOM AND/OR FIXTURE ORIENTATION, DOOR
LOCATION(S), ADJACENT WALL CONSTRUCTION, AND
ADDITIONAL EQUIPMENT ITEMS.
4. DIMENSIONS INDICATED HERE ARE TYPICAL, UNLESS
DIMENSIONED OTHERWISE ON FLOOR PLAN SHEETS OR
INTERIOR ELEVATIONS.
5. DIMENSIONS SHOWN FOR ACCESSORIES AND EQUIPMENT
ITEMS AND CLEAR FLOOR SPACE ARE FROM FACE OF ROOM
FINISH (SUCH AS TILE).
6. NOTE THAT DOORS CANNOT INFRINGE UPON OR SWING INTO
THE REQUIRED RECTANGULAR "CLEAR FLOOR SPACE"
AREAS SHOWN ON ENLARGED PLANS.
7. PLUMBING FIXTURES SHOWN HERE ARE GENERIC - SEE
PLUMBING DRAWINGS FOR ACTUAL SCHEDULED FIXTURES.
8. ORIENT FLUSH LEVER AT TOILETS TO THE OPEN SIDE OF THE
ROOM.
SHR1 ACCESSIBLE TRANSFER
TYPE SHOWER
1'-6"
48" WIDE x 36"
DEEP CLEAR
FLOOR SPACE
CONTROL
WALL
SEAT
WALL
3'-0"
C
L E
A R
M
IN
CLEAR
4'-0"
SHRS
CH 6"
CONTROLS
LOCATED 42" AFF
TO CENTERLINE
GB15/30
M A
X
30" WIDE x 48"
DEEP CLEAR
FLOOR SPACE
4"
WC LOCATION: 16"-18" FROM SIDE WALL,
PER FBC-A 2020 604.2
FBC-A 2020 604.3.1
FBC-A 2020 305
DISPENSER LOCATIONS:
FBC-A 2020 604.7
GRAB BAR LOCATIONS & SIZES:
FBC-A 2020 604.5
FBC-A 2020 305
FBC-A 2020 305
FBC-A 2020 608.2.1
GRAB BAR LOCATIONS AND SIZES:
FBC-A 2020 608.3.1
CONTROLS: FBC-A 2020 608.5.1
8" 8"7
AUDIO/VISUAL
FIRE ALARM
EXIT SIGN WALL
SWITCH
WALL
PHONE
JACK
FIRE ALARM
PULL STATION
(GENERALLY
LOCATE UNDER
A/V ALARM)
W
IT
H O
W N
E R
C O
O R
D
IN
A T
E
8"
COMBINATION
POWER/SIGNAL/OUTLET
FOR WALL MOUNTED
TELEVISION OR
MONITOR
T.V./DATA/
PHONE
POWER
RECEPTACLES
LIGHT
SWITCHES
DOME
LIGHT
OCCUPANCY
SENSOR
CARD
READER
THERMOSTAT
" 5
POWER
DISCONNECT
REMOTE DOOR
RELEASE
"5
NIGHT
LIGHT
TV
D/V
TV E
E
ED/V
L L OS CR T DRLD/V
AREA OF
REFUGE
INTERCOM
M
IN
C L
E A
R
LOCATE ROOM
IDENTIFICATION
SIGN ON LATCH
SIDE OF DOOR
D
IM
E N
S
IO
N S
S E
E C
O D
E S
IG
N
A G
A D
A D
E T
A
IL
S F
O R
9"
SIGN
MEN
CORRESPONDING GRADE II BRAILLE. 1/10"
WITHIN CELL. 2/10" BETWEEN CELLS, 1/40"
MIN. RAISE ABOVE THE BACKGROUND.
WALL MOUNTED SIGNAGE TO BE LOCATED ON LATCH SIDE OF DOOR, CLEAR OF DOOR SWING.
WOMEN
H
IG
H E
S T
L
IN
E O
F T
E X
T
M
A X
T O
B O
T T
O M
O F
O F
L O
W E
S T
L
IN
E O
F T
E X
T
M
IN
T O
B O
T T
O M
EXIT
ROOM
NAME
NUMBER
DESIGNED:
CADD:
TECH REVIEW:
DATE:
SUB SHEET NO: TITLE OF SHEET: DRAWING NO.
PMIS/PKG NO.
OF
A/E FIRM:
PRIME:
SHEET
SUB:
REFERENCE
COVER SHEET
WALKER
ARCHITECTS,
GAINESVILLE, FL
/2
/2
:4
:1
P
M GENERAL
AI
4/29/2024
G0.02TW
TYPICAL TOILET ROOMS AND
MOUNTING HEIGHTS
229154
NPS FIRE OPERATIONS CENTER AT
BIG CYPRESS NATIONAL PRESERVE
1/4" = 1'-0"
ACCESSORIES & PLUMBING FIXTURES
1/4" = 1'-0"
TOILET ROOM TYPICALS
1/4" = 1'-0"
ELECTRICAL CONTROL DEVICES
1/4" = 1'-0"
SPACE SIGNAGE
1 1/2" = 1'-0"
CODE SIGNAGE ADA DETAILS
8. FIRE AND SMOKE PROTECTION FEATURES
GENERAL NOTES
2. AUTHORITIES HAVING JURISDICTION
10. MEANS OF EGRESS
MINIMUM NUMBER OF BUILDING EXITS REQUIRED
BUILDING - TABLE 1017.2
BUILDING - TABLE 1006.2.1
BUILDING - TABLE 1020.3
BUILDING - 1005.3.1 / 1011.2
200 FEET
100 FEET FOR OCC LOAD 30 OR LESS, 70 FEET FOR OCC LOAD OVER 30
36 INCHES REQUIRED / 60 INCHES PROVIDED
36 INCHES REQUIRED / 102 INCHES PROVIDED
1 EXIT REQD. / 2 EXIT PROVIDED LOCATED 1/2 DIAGONAL OF BLDG. BUILDING - 1006.2.1 AND 1007.1.1
MAXIMUM TRAVEL DISTANCE TO EXIT
MAXIMUM COMMON PATH OF TRAVEL
MINIMUM EGRESS WIDTH
CORRIDORS
STAIRS
BUILDING - SECTION 1008NOT REQUIRED AND PROVIDEDEMERGENCY LIGHTING OF EGRESS
9. FIRE PROTECTION SYSTEMS
FIRE SPRINKLERS
BUILDING - 905.3.1
BUILDING - 906.3
BUILDING - 907.2.2
NOT REQUIRED AND NOT PROVIDED
MINIMUM ABC AT 75' MAXIMUM TRAVEL DISTANCE
NOT REQUIRED AND NOT PROVIDED BUILDING - 903.2
STANDPIPES
PORTABLE FIRE EXTINGUISHERS
FIRE ALARM AND DETECTION NOT REQUIRED AND NOT PROVIDED
YES
YES
NATIONAL PARK SERVICES (NPS)
1. THE INTENDED USE OF THE BUILDING IS BASED ON INFORMATION FROM THE OWNER.
2. THE INTENDED USE OF THE BUILDING IS BUSINESS OCCUPANCY FIRE OPERATIONS CENTER
3. ALL DEMOLITION AND CONSTRUCTION INVOLVED TO COMPLETE THIS PROJECT SHALL CONFORM TO ALL
APPLICABLE CODES.
3. APPLICABLE CODES & STANDARDS
INTERNATIONAL BUILDING CODE (IBC), 2021
FLORIDA BUILDING CODE, 2023 (WHEN MORE STRINGENT THAN IBC)
INTERNATIONAL MECHANICAL CODE (IMC), 2021
INTERNATIONAL PLUMBING CODE (IPC), 2021
INTERNATIONAL FUEL GAS CODE (IFGC), 2021
INTERNATIONAL ENERGY CONSERVATION CODE (IECC), 2021
INTERNATIONAL FIRE CODE (IFC), 2021
NFPA 10 2021
NFPA 70 - NATIONAL ELECTRICAL CODE (NEC) 2020
NFPA 90A 2019
NFPA 780 2020
NATIONAL ELECTRICAL SAFETY CODE (NESC) 2017
ABAAS: ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS
ASCE 7-16 (AMERICAN SOCIETY OF CIVIL ENGINEERS) MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER
STRUCTURES
ACI 318-19 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
ACI 301-20 SPECIFICATIONS FOR STRUCTURAL CONCRETE
ASHRAE 55-2010
ASHRAE 62.2-2013
ASHRAE / IES 90.1-2016
ANSI/ASHRAE/IESNA 90.1-2016
CLIMATE CHANGE AND NATURAL HAZARDS HANDBOOK (WASCO CC & NH HANDBOOK)
IEEE STANDARDS
NPS REFERENCE MANUAL 58
INTERNATIONAL WILDLAND URBAN INTERFACE CODE
1. PROJECT SUMMARY
THE PROPOSED PROJECT IS A ONE STORY 5,142 SF NEW BUILDING FOR A FIRE OPERATIONS CENTER AT BIG CYPRESS NATIONAL PRESERVE HEADQUARTERS IN OCHOPEE, FLORIDA. IT IS A PRE-ENGINEERED METAL BUILDING ON SLAB TO GRADE CONCRETE ELEVATED UP TO 7' FROM ITS ORIGINAL ELEVATION, AND DESIGNED TO SUPPORT HIGH-VELOCITY HURRICANE WINDS. CLASIFIED AS CATEGORY IV BUILDING, FOR THE USE AS A SHELTER IN CASE OF EMERGENCY.
4. CLASSIFICATION OF THE WORK
BUILDING CODE CLASSIFICATION OF THE WORK:
NEW CONSTRUCTION (IBC - BUILDING, SECTION 101)
BUILDING CODE REQUIREMENTS:
NEW CONSTRUCTION SHALL COMPLY WITH IBC - BUILDING
5. OCCUPANCY AND HAZARD OF CONTENTS CLASSIFICATION
BUILDING USE AND OCCUPANCY:
THE BUILDING CONTAINS A SINGLE OCCUPANCY GROUP
THE BUILDING OCCUPANCY IS GROUP B - BUSINESS (IBC BUILDING - 304)
THE SINGLE USE BUILDING INCLUDES THE FOLLOWING ACCESSORY OCCUPANCIES (IBC 508.2):
SMALL ASSEMBLY SPACES WITH AN OCCUPANT LOAD OF <50 PERSONS AND <750 GSF (IBC 303.1.2) Accessory occupancies are those occupancies that are ancillary to the main occupancy of the building and are limited to 10% of the floor area of the story in which they are located. The allowable height and number of stories of the building are in accordance with the main occupancy. No separation is required for accessory occupancies, except for those listed at IBC 508.2.4.
THE BUILDING DOES NOT INCLUDE INCIDENTAL USES (IBC 509)
Incidental uses are ancillary functions associated with a given occupancy that generally pose a greater level of risk to that occupancy and are limited to those uses listed in Table 509. They shall not be individually classified occupancies. They shall not occupy more than 10% of the building area of the story in which they are located. They shall be separated from the remainder of the building per Table 509 and 509.4.
INTERNATIONAL BUILDING CODE
6. TYPE OF CONSTRUCTION
THE TYPE OF CONSTRUCTION IS II-B (IBC BUILDING - T601)
BUILDING ELEMENT HOURLY RATING
PRIMARY STRUCTURAL FRAME 0
BEARING WALLS, EXTERIOR 0
BEARING WALLS, INTERIOR 0
NONBEARING WALLS, EXTERIOR SEE BELOW
NONBEARING WALLS, INTERIOR 0
FLOOR CONSTRUCTION 0
ROOF CONSTRUCTION 0
NONBEARING WALLS, EXTERIOR (FBC BUILDING - T705.5)
NOT APPLICABLE TO THE PROJECT
FIRE SEPARATION DISTANCE HOURLY RATING
X < 5' 1 5' < X < 10' 1 10' < X < 30' 0 X > 30' 0
INTERNATIONAL BUILDING CODE
7. BUILDING HEIGHT AND AREA
BUILDING HEIGHT (504.3)
ALLOWABLE: 55'
ACTUAL: 25'
NUMBER OF STORIES ABOVE GRADE (504.4)
ALLOWABLE: 3
ACTUAL: 1
BUILDING AREA (506)
ALLOWABLE: 23,000 GSF
ACTUAL: 6,338 GSF
INTERNATIONAL BUILDING CODE
PROJECT COMPLIES?REFERENCEIBC
YES
YES
BUILDING - 1012.5.1NOT LESS THAN CORRIDORS / 60 INCHES PROVIDEDRAMPS, MEANS OF EGRESS
BUILDING - 1012.5.136 INCHES CLEAR BETWEEN HANDRAILS / 48 INCHES PROVIDEDRAMPS
YES
YES
YES
YES
YES
MAXIMUM DEAD END CORRIDOR BUILDING - TABLE 1020.520 FEET YES
PROJECT COMPLIES?
YES
YES
YES
OCCUPANT LOAD AND EXIT WIDTH CALCULATIONS
SEE SHEET G1.1
EXTERIOR WALLS (IBC 705.5, 705.5, TABLE 601 AND 602)
THE FIRE SEPARATION DISTANCE IS GREATER THAN 30', SO THE RATING REQUIREMENT FOR EXTERIOR
WALLS IS 0 HOURS.
FIRE WALLS (IBC 706)
FIRE WALLS ARE NOT REQUIRED AND NOT PROVIDED.
FIRE BARRIERS (IBC 707)
SHAFT ENCLOSURES NOT APPLICABLE
INTERIOR EXIT STAIRWAYS AND RAMPS NOT APPLICABLE
ENCLOSURES FOR EXIT ACCESS STAIRWAYS NOT APPLICABLE
EXIT PASSAGEWAY NOT APPLICABLE
HORIZONTAL EXIT NOT APPLICABLE
ATRIUMS NOT APPLICABLE
INCIDENTAL USES SEE OCCUPANCY SECTION ABOVE
CONTROL AREAS NOT APPLICABLE
SEPARATED OCCUPANCIES NOT APPLICABLE
FIRE AREAS NOT APPLICABLE
FIRE PARTITIONS (IBC 708)
CORRIDORS (1020.1) NOT REQUIRED (GROUP B, UNSPRINKLERED, <30
OCCUPANT LOAD SERVED)
SMOKE BARRIERS (IBC 709) NOT REQUIRED
SMOKE PARTITIONS (IBC 710) NOT REQUIRED
FLOOR AND ROOF ASSEMBLIES (IBC 711)
SUPPORTING CONSTRUCTION SAME AS ASSEMBLIES BELOW
SEPARATED OCCUPANCIES NOT APPLICABLE
FIRE AREAS NOT APPLICABLE
DWELLING UNITS NOT APPLICABLE
SMOKE COMPARTMENTS NOT APPLICABLE
INCIDENTAL USES SAME AS OCCUPANCY SECTION ABOVE
VERTICAL OPENINGS (IBC 712) NOT APPLICABLE
PENETRATIONS (IBC 714) NOT APPLICABLE (NO RATED WALLS)
FIRE RESISTANT JOINT SYSTEMS (FBC I15)
NOT APPLICABLE (NO RATED WALLS)
PROJECT COMPLIES?REFERENCEIBC
FIXTURE PLUMBING CODE REQUIREMENT
11. PLUMBING FIXTURES
WATER CLOSETS 1 PER 25 FOR THE FIRST 50 AND 1 PER 50 FOR THE REMAINDER
CONFIRMATION OF PROJECT COMPLIANCECALCULATION
21/(50/2) = 1 (.84) PER SEX
LAVATORIES 1 PER 40 FOR THE FIRST 80 AND 1 PER 80 FOR THE REMAINDER 21/(40/2) = 1 (1.05) PER SEX
WATERCLOSETS: REQUIRED: 1 PER SEX
PROVIDED: NEUTRAL = 4
LAVATORIES: REQUIRED: 1 PER SEX
PROVIDED: NEUTRAL = 4DRINKING FOUNTAINS 1 PER 100 OCCUPANTS 42/100 = 1 (.42) REQUIRED
BUSINESS OCCUPANCY = 42 PERSONS
SERVICE SINK 1 REQUIRED 1 REQUIRED IN BUILDING
YES
YES
YES
YES
PROJECT CONDITION
COMPLIES?
DRINKING FOUNTAINS: REQUIRED: 1
PROVIDED: 2 (1 HI / 1 LO)
SERVICE SINK: REQUIRED: 1
PROVIDED: 1
42/2 = 21 PER SEX
12. STAIR REQUIREMENTS
TREAD DEPTH
BUILDING - 1011.5.2
BUILDING - 1011.8
BUILDING - 1014.2
7" MAXIMUM, 4" MINIMUM
12' MAXIMUM
11" MINIMUM BUILDING - 1011.5.2
RISER HEIGHT
MAXIMUM RUN HEIGHT
HANDRAIL HEIGHT 34" - 38"
PROJECT COMPLIES?REFERENCEIBC
BUILDING - 1014.3.1HANDRAIL DIAMETER 1-1/4" - 2" OUTSIDE DIAMETER
BUILDING - 1014.7HANDRAIL DISTANCE FROM WALL 1-1/2"
BUILDING - 1014.9INTERMEDIATE HANDRAILS ALL PORTIONS OF STAIRWAY REQUIRED CAPACITY WITHIN 30" OF RAIL
AREA OF REFUGE OR 48" CLEAR BETWEEN HANDRAILS NOT APPLICABLE YES
PRESSURIZED STAIR TOWER NOT APPLICABLE YES
13. ACCESS REQUIREMENTS
ROOF ACCESS
ACCESSIBILITY - 201.1.1
ACCESSIBILITY - 206.2.1
ACCESSIBILITY - TABLE 208.2
ELEVATOR NOT REQUIRED AND NOT PROVIDED
ONE MINIMUM AND PROVIDED
NOT APPLICABLE BUILDING - 1011.12
VERTICAL ACCESSIBILITY
ACCESSIBLE ROUTE FROM SITE ARRIVAL POINTS
NUMBER OF ACCESSIBLE PARKING SPACES 2 REQUIRED, 2 PROVIDED
YES
YES
YES
YES
PROJECT COMPLIES?REFERENCEIBC
YES
YES
YES
YES
YES
YES
YES
DESIGNED:
CADD:
TECH REVIEW:
DATE:
SUB SHEET NO: TITLE OF SHEET: DRAWING NO.
PMIS/PKG NO.
OF
A/E FIRM:
PRIME:
SHEET
SUB:
REFERENCE
COVER SHEET
WALKER
ARCHITECTS,
GAINESVILLE, FL
/2
/2
:4
:1
P
M AI
AI
4/29/2024
G0.03TW
CODE COMPLIANCE
229154
NPS FIRE OPERATIONS CENTER AT
BIG CYPRESS NATIONAL PRESERVE
15. ENERGY EFFICIENCY - COMMERCIAL14. INTERIOR FINISHES
WALL AND CEILING FINISHES (FBC TABLE 803.11)
CLASS A = FLAME SPREAD 0-25, SMOKE DEVELOPED 0-450
CLASS B = FLAME SPREAD 26-75, SMOKE DEVELOPED 0-450
CLASS C = FLAME SPREAD 76-200, SMOKE DEVELOPED 0-450
GROUP: B
SPRINKLERED: NO
SPACE CLASS REQUIRED CLASS SPECIFIED
INTERIOR EXITS B B
CORRIDORS AND EXIT ACCESS C C
ROOMS AND SPACES C C
CLIMATE ZONE: 1A (ENERGY - TABLE C301.1)
COMPLIANCE PATH: PERFORMANCE / PRESCRIPTIVE
OPAQUE THERMAL ENVELOPE ASSEMBLIES (C402.2, PRESCRIPTIVE)
ELEMENT REQUIRED PROVIDED
ROOF, INSULATION ABOVE DECK NA* R-19 + R-11 LS
WALLS, METAL FRAMED NA* R13 + R6.5ci
WALLS, BELOW GRADE NA* NOT REQUIRED
FLOORS, JOIST/FRAMING NA* NOT REQUIRED
FLOORS, SLAB ON GRADE NA* NOT REQUIRED
DOORS, OPAQUE NA* R4.75
* PROJECT FOLLOWS PERFORMANCE ENERGY MODEL PATH, NO PRESCRIPTIVE REQUIREMENT
ROOF SOLAR REFLECTANCE AND THERMAL EMITTANCE (C402.3, PRESCRIPTIVE)
REQUIRED PROVIDED
3-YEAR AGED SR OF 0.63 AND
3 YEAR AGED THERMAL EMITTANCE OF 0.75 SR: 0.67 TE: 0.87
OR
3-YEAR AGED SRI OF 75 SRI: 81
FENESTRATION (C402.4, PRESCRIPTIVE)
ELEMENT REQUIRED PROVIDED
U-FACTOR
FIXED NA* 0.50
OPERABLE NA* 0.65
ENTRANCE DOORS NA* 1.10
SHGC
SOUTH, EAST, WEST NA* 0.25
NORTH NA* 0.35
SKYLIGHTS
U-FACTOR NA* NO SKYLIGHTS
SHGC NA* NO SKYLIGHTS
MAXIMUM AREA, VERTICAL NA*
MAXIMUM AREA, SKYLIGHTS NA*
* PROJECT FOLLOWS PERFORMANCE ENERGY MODEL PATH, NO PRESCRIPTIVE REQUIREMENT
FLOOR FINISHES (FBC 804.4.2)
CLASS I = MINIMUM CRITICAL RADIANT FLUX 0.45 WATTS/CM2
CLASS II = MINIMUM CRITICAL RADIANT FLUX 0.22 WATTS/CM2
GROUP: B
SPRINKLERED: YES
CLASS REQUIRED CLASS SPECIFIED
II II
DESIGNED:
CADD:
TECH REVIEW:
DATE:
SUB SHEET NO: TITLE OF SHEET: DRAWING NO.
PMIS/PKG NO.
OF
A/E FIRM:
PRIME:
SHEET
SUB:
REFERENCE
COVER SHEET
WALKER
ARCHITECTS,
GAINESVILLE, FL
/2
/2
:3
:1
P
M
AI
AI
4/29/2024
G0.04TW
CODE COMPLIANCE
229154
NPS FIRE OPERATIONS CENTER AT
BIG CYPRESS NATIONAL PRESERVE
TOTAL EXIT TRAVEL DISTANCE
(Two distinct paths to exit available.)
Maximum: 300'
EGRESS WIDTH PROVIDED
(INCHES, xx")
EGRESS CAPACITY PROVIDED
(PERSONS)
EGRESS CAPACITY UTILIZED
(PERSONS)
COMMON PATH OF EGRESS
TRAVEL DISTANCE
(Portion of exit access travel distance prior to having two distinct paths to exit) Maximum: 100'
GENERAL NOTE:
PROVIDE TACTILE EXIT SIGNAGE AT EACH REQUIRED EXIT DOOR.
CITATION REFERENCE: FBC-B (2020) 1013.4, & NFPA 101 (2018) 7.10.1.3.
PLAN LEGEND
FIRE EXTINGUISHER CABINET
(MOUNT WITH CENTER OF CABINET
36" ABOVE FINISH FLOOR)
E
F.E.C.
LIGHTED EXIT SIGN WITH BATTERY
BACK-UP
(SEE ELECTRICAL)
BUSINESS (BUSINESS OCC):
AREA CALCULATION 1/150 gsf
EXIT
D EXIT DISCHARGE
ACCESSORY MECHANICAL (BUSINESS OCC):
AREA CALCULATION 1/300 gsf
ACCESSORY STORAGE (BUSINESS OCC):
AREA CALCULATION 1/300 gsf
EXERCISE (BUSINESS OCC):
AREA CALCULATION 1/50 gsf
0 0
Distance: x'-x"
Total
Distance: x'-x"
Common
SPACE USE
ACCESSORY EQUIPMENT (BUSINESS OCC):
AREA CALCULATION 1/300 gsf
A
B C
D E F
G
3,196 SF
BUSINESS
140 SF
ACCESSORY
MECHANICAL
89 SF
BUSINESS
100 SF
ACCESSORY
EQUIPMENT
100 SF
ACCESSORY
EQUIPMENT
384 SF
ACCESSORY
STORAGE
100 SF
ACCESSORY
STORAGE
E D
D
E
F.E.C.
F.E.C.
859 SF
EXERCISE
FLOOR AREA INSIDE EXTERIO WALLS = 4,971 GSF
BASE BID - BUILDING AREA UNDER
HORIZONTAL PROJECTION OF THE
ROOF = 6,338 SF
OPTION - BUILDING AREA UNDER
HORIZONTAL PROJECTION OF THE
ROOF = 1,457 SF
BUILDING AREA UNDER
HORIZONTAL PROJECTION OF THE
ROOF INCLUDING BASE BID AND
OPTION = 7,795 SF
EXTERIOR FLOOR AREA = 1, 329 SF
TO PUBLIC WAY
MAXIMUM TRAVEL
DISTANCE TO EXIT =
79'-0" < 300' = OK
TO PUBLIC WAY
MAXIMUM TRAVEL
DISTANCE TO EXIT =
116'-0" < 300' = OK
66 330
EXIT DOOR
COMMON PATH =
0-0" < 100' = OK
EGRESS PATH
SERVES MAXIMUM
21 PEOPLE < 30
66 330
EXIT DOOR
CORRIDORS
SERVES MAXIMUM
21 PEOPLE < 30
ACCESSORY EQUIPMMENT: 198 GSF
ACCESSORY MECHANICAL: 258
ACCESSORY STORAGE: 497
BUSINESS: 3,159 GSF
EXERCISE: 859 GSF
TOTAL OCCUPIABLE FLOOR AREA = 4,971 SF
TOTAL OCCUPANTS = 42
MIN. EGRESS DOOR WIDTH REQD. = 8 INCH
33 INCH PROVIDED
* FLOOR AREA TABULATION
* SEE CODE COMPLIANCE SUMMARY
B A
S E
B
ID
C L
IN
WHEELCHAIR MAXIMUM
TRAVEL DISTANCE TO
GRADE LEVEL
= 85'-0"
OCCUPANT LOAD SCHEDULE
LEVEL FUNCTION OF SPACE (FBC-B 1004.5) AREA
OCCUPANT LOAD
FACTOR (FBC-B 1004.5)
OCCUPANT
LOAD
MIN. EGRESS
WIDTH
(INCHES)
MIN. EGRESS
WIDTH ON
STAIRS
(INCHES) COMMENTS
LEVEL 1 ACCESSORY EQUIPMENT 100 SF 300 SF 0.33 0.07 0.10
LEVEL 1 ACCESSORY EQUIPMENT 100 SF 300 SF 0.33 0.07 0.10
LEVEL 1 ACCESSORY MECHANICAL 140 SF 300 SF 0.47 0.09 0.14
LEVEL 1 ACCESSORY STORAGE 384 SF 300 SF 1.28 0.26 0.38
LEVEL 1 ACCESSORY STORAGE 100 SF 300 SF 0.33 0.07 0.10
LEVEL 1 BUSINESS 3,196 SF 150 SF 21.31 4.26 6.39
LEVEL 1 BUSINESS 89 SF 150 SF 0.59 0.12 0.18
LEVEL 1 EXERCISE 859 SF 50 SF 17.18 3.44 5.15
4,969 SF 41.83 8.37 12.55
3/16" = 1'-0"
FLOOR PLAN - LEVEL 1 - LIFE SAFETY
N
DESIGNED:
CADD:
TECH REVIEW:
DATE:
SUB SHEET NO: TITLE OF SHEET: DRAWING NO.
PMIS/PKG NO.
OF
A/E FIRM:
PRIME:
SHEET
SUB:
REFERENCE
COVER SHEET
WALKER
ARCHITECTS,
GAINESVILLE, FL
/2
/2
:4
:1
P
M AI
AI
4/29/2024
G1.01TW
LEVEL 1 LIFE SAFETY PLAN
229154
NPS FIRE OPERATIONS CENTER AT
BIG CYPRESS NATIONAL PRESERVE
DESIGNED:
CADD:
TECH REVIEW:
DATE:
SUB SHEET NO: TITLE OF SHEET: DRAWING NO.
PMIS/PKG NO.
OF
A/E FIRM:
PRIME: MGM
TFC
03/12/2024
DHY SHEETNPS FIRE OPERATIONS CENTER AT
BIG CYPRESS NATIONAL PRESERVE
SUB:
CHW, INC.
WALKER
ARCHITECTS,
GAINESVILLE, FL
GAINESVILLE, FL
1. THE TOPOGRAPHIC AND EXISTING INFORMATION SHOWN HEREON WERE TAKEN FROM A TOPOGRAPHIC SURVEY PREPARED BY CHW, AND DATED
OCTOBER 24, 2022.
2. THE LOCATION OF ALL EXISTING UTILITIES SHOWN ON THE PLANS HAS BEEN DETERMINED FROM THE BEST INFORMATION AVAILABLE. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR ACCURACY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE VARIOUS UTILITIES AND TO MAKE NECESSARY ARRANGEMENTS FOR ANY RELOCATION OF THESE UTILITIES WITH THE OWNER OF THE UTILITY. THE CONTRACTOR SHALL EXERCISE CAUTION WHEN CROSSING ANY UNDERGROUND UTILITY, WHETHER SHOWN ON THE PLANS OR LOCATED BY THE UTILITY COMPANY. THE RESPECTIVE UTILITY COMPANIES SHALL RELOCATE ALL UTILITIES THAT INTERFERE WITH THE PROPOSED CONSTRUCTION. THE CONTRACTOR SHALL COOPERATE WITH THE UTILITY COMPANIES DURING THE RELOCATION OPERATIONS. ANY DELAY OR INCONVENIENCE CAUSED TO THE CONTRACTOR BY THE VARIOUS UTILITIES SHALL BE INCIDENTAL TO THE CONTRACT AND NO EXTRA COMPENSATION WILL BE ALLOWED.
3. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION IN AREAS OF BURIED UTILITIES AND SHALL PROVIDE AT LEAST 48 HOURS NOTICE TO THE APPROPRIATE UTILITY COMPANIES IN ORDER TO ALLOW MARKING OF THE LOCATIONS OF EXISTING UNDERGROUND FACILITIES IN ADVANCE OF CONSTRUCTION BY CALLING THE FLORIDA SUNSHINE STATE ONE-CALL CENTER, INC. AT 1-800-432-4770 OR 811. IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY "SUNSHINE" 48 HOURS PRIOR TO ANY CLEARING OF CONSTRUCTION TO IDENTIFY ALL UTILITY LOCATIONS. NO
CONSTRUCTION ACTIVITY MAY OCCUR UNTIL THE UTILITIES HAVE BEEN PROPERLY MARKED.
4. THE CONTRACTOR SHALL FIELD VERIFY THE HORIZONTAL LOCATION AND VERTICAL LOCATION OF ALL EXISTING UTILITIES WITHIN THE LIMITS OF THE PROJECT ENVELOPE SHOWN PRIOR TO COMMENCING WORK. THE CONTRACTOR SHALL CALL ALL UTILITY COMPANIES TO HAVE THE LOCATIONS OF ALL UTILITIES FIELD MARKED PRIOR TO COMMENCEMENT OF CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF
THE ENGINEER PRIOR TO CONTINUING CONSTRUCTION.
5. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING ANY DAMAGE TO EXISTING FACILITIES, ABOVE OR BELOW GROUND THAT MAY OCCUR AS A
RESULT OF THE WORK PERFORMED BY THE CONTRACTOR.
6. ALL PRIVATE AND PUBLIC PROPERTY AFFECTED BY THIS WORK SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN EXISTING CONDITIONS BEFORE COMMENCING CONSTRUCTION WORK, UNLESS SPECIFICALLY EXEMPTED BY THE PLANS. ADDITIONAL COSTS ARE INCIDENTAL TO
OTHER CONSTRUCTION AND NO EXTRA COMPENSATION WILL BE ALLOWED.
7. ALL WORK PERFORMED SHALL COMPLY WITH THE REGULATIONS AND ORDINANCES OF THE VARIOUS GOVERNMENTAL AGENCIES HAVING
JURISDICTION OVER THE WORK INCLUDING LANDSCAPING.
8. IT IS THE CONTRACTOR'S RESPONSIBILITY TO BECOME FAMILIAR WITH THE PERMIT AND INSPECTION REQUIREMENTS OF THE VARIOUS GOVERNMENTAL AGENCIES. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION AND SCHEDULE INSPECTIONS
ACCORDING TO AGENCY AND/OR MUNICIPALITY INSTRUCTIONS.
9. IT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO COMPLY WITH AND ENFORCE ALL APPLICABLE SAFETY REGULATIONS.
10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING EXCAVATIONS AGAINST COLLAPSE AND SHALL PROVIDE BRACING, SHEETING OR SHORING AS NECESSARY. TRENCHES SHALL BE KEPT DRY WHILE PIPES ARE BEING PLACED. DEWATERING SHALL BE USED AS REQUIRED, AND PERMITTED THROUGH LOCAL GOVERNMENTAL AGENCIES AND WATER MANAGEMENT DISTRICT PER CURRENT REGULATIONS AT THE SOLE COST OF THE
CONTRACTOR.
11. CONTRACTOR TO REVIEW GEOTECHNICAL REPORT AND BORINGS PRIOR TO BIDDING THE PROJECT AND FOLLOW OUTLINED CONSTRUCTION
TECHNIQUES.
12. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING APPLICABLE TESTING WITH THE SERVICES OF AN APPROVED TESTING LABORATORY AND/OR SOILS ENGINEER, APPLICABLE REGULATORY AGENCIES, AND AS MAY BE FOUND IN THE ENGINEERING CONSTRUCTION DRAWINGS OR SPECIFICATIONS. CONTRACTOR TO VERIFY ALL TESTING WITH THE OWNER PRIOR TO COMMENCING CONSTRUCTION. UPON COMPLETION OF THE WORK, THE TESTING LABORATORY AND/OR SOILS ENGINEER MUST SUBMIT TO THE OWNER'S ENGINEER CERTIFICATIONS STATING THAT ALL
REQUIREMENTS HAVE BEEN MET.
13. INSTALL SILT FENCE PRIOR TO SITE DEMOLITION OR NEW SITE CONSTRUCTION. INSTALL SILT FENCE PER FLORIDA STORMWATER EROSION AND SEDIMENTATION CONTROL INSPECTOR'S MANUAL AND PROVIDE TOE-IN. THE CONTRACTOR SHALL MAINTAIN THE SILT FENCE IN WORKING ORDER THROUGHOUT THE CONSTRUCTION PHASE. THE PROJECT SILT FENCE SHALL BE INSPECTED DAILY AND ANY CORRECTIVE MEASURES SHALL BE
COMPLETED WITHIN 24 HOURS.
14. ALL TREE BARRICADES AND SILT FENCING SHALL BE INSTALLED PRIOR TO COMMENCEMENT OF ANY DEMOLITION OR CONSTRUCTION ACTIVITIES.
15. THE CONTRACTOR IS TO PREPARE THE SITE PRIOR TO BEGINNING ACTUAL CONSTRUCTION IN ACCORDANCE WITH THE GEOTECHNICAL REPORT.
16. ALL DELETERIOUS MATERIAL (I.E. MUCK, PEAT, BURIED DEBRIS) IS TO BE EXCAVATED IN ACCORDANCE WITH THESE PLANS OR AS DIRECTED BY THE OWNER'S ENGINEER OR OWNER'S SOIL TESTING COMPANY. DELETERIOUS MATERIAL IS TO BE STOCKPILED AND REMOVED FROM THE SITE. EXCAVATED AREAS ARE TO BE BACKFILLED WITH APPROVED MATERIALS AND COMPACTED AS SHOWN ON THESE AREAS.
17. CONTRACTOR SHALL CLEAR AND GRUB ONLY THOSE PORTIONS OF THE SITE NECESSARY FOR CONSTRUCTION. DISTURBED AREAS SHALL BE SODDED, SEEDED, MULCHED, OR PLANTED WITH OTHER APPROVED LANDSCAPE MATERIAL, AS DIRECTED BY THESE PLANS, IMMEDIATELY FOLLOWING
CONSTRUCTION PER LOCAL INSPECTOR.
18. WORK BEING PERFORMED UNDER THIS CONTRACT SHALL INTERFACE SMOOTHLY WITH OTHER WORK BEING PERFORMED ON THE SITE BY OTHER CONTRACTORS AND/OR UTILITY COMPANIES. IT WILL BE NECESSARY FOR THE CONTRACTOR TO COORDINATE AND SCHEDULE HIS ACTIVITIES, WHERE
NECESSARY, WITH OTHER CONTRACTORS AND UTILITY COMPANIES.
19. ALL PAVEMENT DIMENSIONS SHOWN ARE TO EDGE OF PAVEMENT UNLESS OTHERWISE NOTED.
20. THE GOVERNING STANDARDS AND SPECIFICATIONS, UNLESS STATED OTHERWISE SHALL BE PER FLORIDA DEPARTMENT OF TRANSPORTATION STANDARD PLANS (FY 2023-24 ROAD CONSTRUCTION) AND STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION DATED JANUARY 2023, AS AMENDED BY CONTRACT DOCUMENTS. ALL MATERIALS AND METHODS SHALL MEET FDOT SPECIFICATIONS AND SHALL BE PRODUCED OR
OBTAINED FROM AN FDOT APPROVED SOURCE.
21. ALL NEW TRAFFIC CONTROL DEVICES (SIGNS AND PAVEMENT MARKINGS) SHALL CONFORM TO THE MANUAL ON UNIFORM TRAFFIC CONTROL
DEVICES (MUTCD) AND FDOT STANDARDS.
22. ALL STRIPING WITHIN THE FDOT RIGHT OF WAY SHALL BE PLACED FIRST AS TEMPORARY STRIPING FOLLOWED BY APPLICATION OF
THERMOPLASTIC STRIPING 30 DAYS LATER.
23. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING PROPER BENCHMARKS ON-SITE. EXISTING BENCH MARKS SCHEDULED FOR REMOVAL SHALL BE
RELOCATED AT CONTRACTORS EXPENSE AND RE-ESTABLISHED BY A LICENSED SURVEYOR.
24. ALL HANDICAP RAMPS SHALL COMPLY WITH THE FLORIDA ACCESSIBILITY CODE AND AMERICANS WITH DISABILITIES ACT.
25. A PRE-CONSTRUCTION CONFERENCE SHALL BE REQUIRED. THE CONTRACTOR, ENGINEER OF RECORD, AND THE OWNER SHALL MEET PRIOR TO
INITIATION OF SITE CONSTRUCTION.
26. ANY CHANGE ORDER REQUESTS, SITE REVISIONS, AND PAY REQUESTS MUST BE SUBMITTED TO AND APPROVED BY THE ENGINEER OF RECORD.
27. CONTRACTOR IS RESPONSIBLE FOR ALL DEWATERING AS NEEDED THROUGHOUT ALL CONSTRUCTION ACTIVITIES COVERED BY THESE PLANS.
DEWATERING SHALL BE DONE IN ACCORDANCE WITH FDOT STANDARD SPECIFICATIONS, 2023 EDITION, SECTION 120.
28. THE CONTRACTOR IS RESPONSIBLE FOR THE PERFORMANCE AND COST OF ALL CLEARING AND GRUBBING AND ALL WORK OF REMOVAL, DISPOSAL, AND REPAIR OR REPLACEMENT OF EXISTING IMPROVEMENTS WHERE SHOWN IN THE PLANS, OR ORDERED BY THE ENGINEER TO BE REMOVED, OR WHERE REQUIRED BECAUSE OF THE CONSTRUCTION OPERATIONS, IN ORDER TO CONSTRUCT THE PROPOSED IMPROVEMENTS (THIS INCLUDES BUT IS
NOT LIMITED TO PROPOSED PIPING, STRUCTURES, UTILITIES, PAVING, CURBING, ETC.).
29. AN AS-BUILT SURVEY MAY BE REQUIRED BY REGULATORY AGENCIES. CONTRACTOR TO COORDINATE WITH PROJECT OWNER FOR COMPLETION OF
AS-BUILT SURVEYS PRIOR TO PROJECT / PERMIT CLOSE-OUT.
1. THE CONTRACTOR SHALL BE RESPONSIBLE TO DISPOSE OF ALL DEMOLITION MATERIALS IN A SAFE AND LAWFUL MANNER. THE CONTRACTOR SHALL SALVAGE TO THE OWNER ANY ITEM AS DETERMINED BY THE OWNER. ONCE DEMOLISHED, MATERIAL SHALL BE DISPOSED OF PROPERLY AND
IMMEDIATELY.
2. REMOVE ALL IMPROVEMENTS DEFINED ON THE DEMOLITION PLAN. SALVAGE ITEMS TO OWNER AS DEFINED BY THE OWNER'S REPRESENTATIVE AND
CONSTRUCTION DOCUMENT SPECIFICATIONS.
3. EXISTING PAVEMENT AND SIDEWALK EDGES THAT BORDER NEW CONSTRUCTION OR DEMOLITION ARE TO BE SAW-CUT TO PROVIDE A SMOOTH
TRANSITION.
4. ALL EXISTING TREES ARE TO REMAIN UNLESS OTHERWISE NOTED.
5. ROOTS LARGER THAN 1 INCH IN DIAMETER ON TREES TO BE PRESERVED THAT ARE ENCOUNTERED DURING CONSTRUCTION MUST BE CUT CLEANLY
AND COVERED OVER WITH SOIL BY THE END OF THE WORKING DAY.
6. ALL ASPHALT AND LIMEROCK WILL BE COMPLETELY REMOVED FROM AREAS THAT WILL BE LANDSCAPED. IN PARTICULAR, AREAS WHERE ASPHALT WILL BE REMOVED MUST HAVE THE TOP HARD SURFACE, LIMEROCK, AND COMPACTED SOIL REMOVED. REPLACEMENT SOIL SHALL BE CLEAN DEEP FILL OF PH 5.5 - 6.5. THE DEPTH OF UNCOMPACTED SOIL PRIOR TO PLANTING MUST BE AT LEAST 3 FEET TO ACCOMMODATE FUTURE TREE ROOT GROWTH.
NO LIMEROCK, LARGE STONES, OR OTHER CONSTRUCTION DEBRIS CAN REMAIN IN AREAS TO BE LANDSCAPED.
1. THE CONTRACTOR IS RESPONSIBLE FOR EROSION/SEDIMENTATION CONTROL PRACTICES DURING CONSTRUCTION TO MINIMIZE ON-SITE EROSION/SEDIMENTATION AND TO PROTECT AGAINST DAMAGE TO OFF SITE PROPERTY. THE FOLLOWING PRACTICES SHALL BE EMPLOYED:
A. EROSION AND SEDIMENTATION CONTROL SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. AREAS OF OFF-SITE DISCHARGE DURING CONSTRUCTION SHALL BE PROTECTED WITH A SEDIMENT BARRIER PER FLORIDA STORMWATER EROSION AND SEDIMENTATION CONTROL INSPECTOR'S MANUAL TO PREVENT OFF-SITE DISCHARGE OF SEDIMENTS. A SILT BARRIER SHALL SPECIFICALLY BE REQUIRED, CONSTRUCTED, AND MAINTAINED AS INDICATED ON THIS SHEET. TEMPORARY SEED AND MULCH SHOULD BE USED TO CONTROL ON-SITE EROSION WHEN IT IS NOT PRACTICAL TO ESTABLISH PERMANENT VEGETATION. SOD SHALL BE PLACED AS EARLY AS POSSIBLE ON ALL SLOPES STEEPER THAN 5 (FT) HORIZONTAL TO 1 (FT) VERTICAL. SOD SHALL BE PINNED AS REQUIRED. ALL EROSION AND SEDIMENTATION CONTROL MEASURES SHALL BE MAINTAINED IN WORKING ORDER THROUGHOUT THE CONSTRUCTION PHASE. THE CONTRACTOR SHALL INSPECT AND REPAIR AS NECESSARY THE EROSION/SEDIMENTATION
PROTECTION AT THE END OF EACH WORKING DAY.
NOTE: EROSION/SEDIMENTATION CONTROL SHALL BE PLACED PRIOR TO SITE EXCAVATION AND SHALL REMAIN IN PLACE UNTIL SITE VEGETATION
AND LANDSCAPING IS COMPLETE.
B. ALL INLET STRUCTURES AND PIPE SHALL BE PROTECTED FROM SILTATION BY CONSTRUCTING INLET PROTECTION AS DEFINED BY THESE PLANS OR IN THE FDOT STANDARDS. IF SILTATION OCCURS, THE CONTRACTOR IS RESPONSIBLE TO REMOVE SILTATION AS PART OF THE BASE CONTRACT AT
NO ADDITIONAL COST TO THE OWNER.
C. PERMANENT VEGETATIVE STABILIZATION SHALL BE APPLIED ON FINE GRADED SITES AS SOON AS PRACTICAL. TEMPORARY SEEDING SHOULD BE EMPLOYED TO PREVENT EXPOSURE OF BARREN SOILS UNTIL PERMANENT VEGETATION CAN BE APPLIED.
D. ALL SLOPES 1:3 OR STEEPER REQUIRE LAPPED OR PEGGED SOD.
E. EROSION, SEDIMENT AND TURBIDITY CONTROL ARE THE RESPONSIBILITY OF THE CONTRACTOR. THESE DELINEATED MEASURES ARE THE MINIMUM REQUIRED, WITH ADDITIONAL CONTROLS TO BE UTILIZED AS NEEDED, DEPENDENT UPON ACTUAL SITE CONDITIONS AND CONSTRUCTION OPERATION.
F. ALL SYNTHETIC BALES, SILT FENCE, AND OTHER EROSION CONTROL MEASURES SHALL BE REMOVED AT THE COMPLETION OF THE PROJECT.
2. THE CONTRACTOR SHALL MAINTAIN IN HIS POSSESSION A COPY OF THE WATER MANAGEMENT DISTRICT CONSTRUCTION PERMIT. HE SHALL BE
RESPONSIBLE FOR ADHERENCE TO ALL CONDITIONS CONTAINED IN THE PERMIT.
3. PROPOSED SPOT ELEVATIONS REPRESENT FINISHED PAVEMENT OR GROUND SURFACE GRADE UNLESS OTHERWISE NOTED ON DRAWINGS.
4. CONTRACTOR SHALL SUBMIT FOR REVIEW TO THE OWNER AND OWNER'S ENGINEER SHOP DRAWINGS ON ALL PRECAST AND MANUFACTURED ITEMS TO BE USED ON THIS SITE. FAILURE TO OBTAIN APPROVAL BEFORE INSTALLATION MAY RESULT IN REMOVAL AND REPLACEMENT AT CONTRACTOR'S EXPENSE. ENGINEER'S APPROVAL OF A SHOP DRAWING DOES NOT RELIEVE THE CONTRACTOR'S RESPONSIBILITY FOR THE PERFORMANCE OF THE ITEM.
5. THE COST OF ALL TESTING OF COMPACTION AND OTHER REQUIRED TESTS SHALL BE PAID BY THE CONTRACTOR AND MADE AVAILABLE TO THE
ENGINEER OF RECORD DURING SITE INSPECTIONS.
6. GENERAL CONTRACTOR TO CONTACT ENGINEER OF RECORD AND THE OWNER REPRESENTATIVE 48 HOURS IN ADVANCE PRIOR TO BACKFILLING
TRENCHES FOR FIELD INSPECTION AND PRIOR TO LAYING ASPHALT FOR FIELD INSPECTION.
7. CONTRACTOR IS TO SUBMIT FDOT APPROVED ASPHALT DESIGN MIXES TO THE OWNER'S REPRESENTATIVE AND ENGINEER OF RECORD BEFORE ANY WORK IS TO COMMENCE ON PROJECT. THE MIXTURE AT THE PLANT OR ON THE ROAD SHALL NOT EXCEED 335 DEGREES. THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE AND PROVIDE TEMPERATURE READINGS PRIOR TO LAYING ASPHALT.
8. AS DETERMINED NECESSARY AND DIRECTED BY THE OWNER'S REPRESENTATIVE AND ENGINEER OF RECORD, THE CONTRACTOR SHALL UNDERCUT ALL UNSUITABLE MATERIAL 24 INCHES BELOW THE BOTTOM OF ANY PROPOSED LIMEROCK BASE, AND SHALL BACKFILL WITH FILL MATERIAL MEETING FDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. SEE FDOT INDEX 120-001 AND 120-002.
9. PROVIDE LEVEL PLATFORM IN FRONT OF ALL EGRESS DOORS. THE FLOOR SURFACE ON BOTH SIDES OF A DOOR SHALL BE AT THE SAME ELEVATION.
THE FLOOR SURFACE OR LANDING ON EACH SIDE OF THE DOOR SHALL EXTEND FROM THE DOOR IN THE CLOSED POSITION A DISTANCE EQUAL TO THE DOOR WIDTH AND SHALL COMPLY WITH SECTION 4.13.6 MANEUVERING CLEARANCES AT DOORS OF THE FLORIDA ACCESSIBILITY CODE FOR BUILDING
CONSTRUCTION.
10. THE CONTRACTOR SHALL STOCKPILE TOPSOIL AND CONSTRUCTION MATERIALS IN AREAS DESIGNATED BY THE OWNER.
11. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING RECORD DRAWINGS OR AS-BUILT SURVEY AS NOTED IN NOTE #29 UNDER SITE GENERAL NOTES.
12. ALL CONCRETE USED SHALL BE 2,500 PSI MINIMUM.
13. ALL WELLS, CLEANOUTS, MANHOLE TOPS, PULL BOX COVERS AND OTHER UTILITY APPURTENANCES IN THE AREA OF REDEVELOPMENT SHALL BE
PROTECTED AND TOPS ADJUSTED TO MATCH PROPOSED GRADES.
14. CONTRACTOR SHALL SAW CUT, TACK, AND MATCH EXISTING PAVEMENT AT LOCATIONS WHERE NEW PAVEMENT MEETS ANY EXISTING PAVEMENT.
15. SOD SHALL BE PLACED AROUND ALL STRUCTURES AS DIRECTED BY FDOT INDEX 524-001 AND FDOT INDEX 425- AND 430- SERIES AS APPROPRIATE.
ALL OTHER DISTURBED AREAS SHALL BE SEEDED AND MULCHED.
16. ALL STORM SEWER CURB AND DITCH BOTTOM INLETS SHALL CONFORM TO THE APPLICABLE FDOT STANDARD PLANS ALL DRAINAGE STRUCTURES WITH GRATES THAT ARE LOCATED IN GRASSED AREAS SHALL HAVE THE GRATE CHAINED TO THE STRUCTURE USING AN EYE BOLT AND CHAIN.
17. ALL CONCRETE STRUCTURES SHALL HAVE ALL EXPOSED EDGES CHAMFERED 3/4" AND CLASS I SURFACE FINISH.
18. ALL HDPE FITTINGS AND CONNECTORS SHALL BE WATER TIGHT. SEE SPECIFICATIONS FOR MORE INFORMATION.
19. COMPACTION OF ALL MATERIALS SHALL BE LIMITED TO STATIC MODE ONLY, UNLESS DIRECTED OTHERWISE BY THE ENGINEER OF RECORD.
20. ALL RCP PIPE JOINTS SHALL BE WRAPPED WITH FILTER FABRIC IN ACCORDANCE WITH FDOT STANDARD SPECIFICATION SECTION 430.
1. ALL ELECTRICAL UTILITIES AND INFORMATION SHOWN ON THE CIVIL PLANS ARE FOR LOCATION AND COORDINATION PURPOSES ONLY. REFER TO
ELECTRICAL PLANS BY OTHERS FOR THE ELECTRICAL DESIGN AND DETAILS.
1. ALL CONSTRUCTION MATERIALS AND METHODS FOR POTABLE WATER, WASTEWATER, AND RECLAIMED WATER SYSTEMS SHALL CONFORM TO NPS MOST RECENT POTABLE WATER, WASTEWATER, & RECLAIMED WATER SYSTEM DESIGN STANDARDS AND APPROVED MATERIALS MANUAL.
2. POTABLE WATER AND WASTEWATER MAINS SHALL MAINTAIN A MINIMUM 10 FEET HORIZONTAL AND 1.5 FOOT VERTICAL SEPARATION.
3. A MINIMUM HORIZONTAL SEPARATION OF 10 FEET FOR POTABLE WATER MAINS, WASTEWATER FORCE MAINS, AND RECLAIMED WATER MAINS, AND 15 FEET FOR GRAVITY WASTEWATER MAINS SHALL BE PROVIDED AND MAINTAINED FROM BUILDINGS, TRANSFORMERS, AND ALL PERMANENT STRUCTURES. SERVICE LATERALS REQUIRE 5 FEET LESS CLEARANCE FOR EACH OF THE UTILITIES.
4. 2" VALVES LOCATED IN PAVED AREAS, INCLUDING SIDEWALKS, SHALL BE GRU APPROVED CAST IRON, RESILIENT SEAT GATE VALVES WITH STANDARD 2" OPERATING NUT, THREADED WITH BRASS NIPPLE BETWEEN THE VALVES AND TAPPING SADDLE OR TAPPED TEE.
5. ANCHORING TEES, COUPLINGS, AND BENDS SHALL BE USED ON ALL FIRE HYDRANT ASSEMBLIES.
6. ALL PRESSURIZED MAIN FITTINGS SHALL BE MECHANICAL JOINT WITH RESTRAINED JOINT GLANDS.
7. ALL SANITARY WASTEWATER SERVICE LATERALS SHALL BE MIN. 4” DIAMETER PVC (SDR 26) AT 1.00% MIN. SLOPE UNLESS OTHERWISE LABELED.
8. WASTEWATER CLEANOUT COVERS LOCATED WITHIN PAVEMENT AND SIDEWALKS ADJACENT TO PAVED AREAS SHALL BE RATED FOR TRAFFIC LOAD BEARING. WASTEWATER CLEANOUT COVERS IN OTHER SIDEWALKS/WALKWAYS SHALL BE BRASS WITH A SQUARE RECESS.
9. MANHOLES WHICH ARE NOT INSTALLED UNDER PAVEMENT SHALL HAVE A RIM ELEVATION AT LEAST 6” ABOVE FINISHED GRADE, AND A 10:1 SLOPE
TO FINISHED GRADE.
PRINCIPLE POST
POSITION (CANTED
20° TOWARD FLOW)
OPTIONAL
POST POSITIONS
POST (OPTIONS: 2" X 4" OR
2 1/2" MIN. DIA. WOOD; STEEL
1.33 LBS/FT. MIN.)
FILTER FABRIC (IN
CONFORMANCE WITH
SEC. 985 FDOT SPEC.)
T
O
O
R M
O R
E
M
IN
ELEVATION
SILT FLOW
SECTION
V E R
T
IC
A L
20°
FILTER FABRIC
NTS
6' MAX.
MIN. LBR 40 COMPACTION 98%
2" TYPE SP-12.5
ASPHALTIC CONCRETE
AASHTO T-180
MIN. LBR 150 COMPACTION 98%
8" CRUSHED CONCRETE BASE
12" STABILIZED TYPE B SUBGRADE
AASHTO T-180
NTS
NOTES:
1. SAWCUT CONTROL JOINTS SHALL BE CONSTRUCTED 5 FEET ON
CENTER
2. EXPANSION JOINTS WITH PREFORMED JOINT FILLER SHALL BE
CONSTRUCTED BETWEEN ALL FIXED OBJECTS AND WALK AND AT
CONSTRUCTION JOINTS.
NTS
6"
WIDTH - SEE SITE PLAN
THICK SLAB EDGE
PAVEMENT
MAX. 2%SLOPE
4" THICK CONC.SLAB
(2500 PSI, CLASS NS) ON CLEAN
COMPACTED EARTH FILL.
NTS
PLACE THE END POST OF
ONE FENCE INSIDE THE END
POST OF THE OTHER FENCE
ROTATE BOTH POSTS AT LEAST
180° IN A CLOCKWISE DIRECTION
TO CREATE A TIGHT SEAL WITH
THE FABRIC MATERIAL
DRIVE BOTH POSTS ABOUT
12" INTO THE GROUND AND
BURY THE FLAP IN A TRENCH
FOR ATTACHING TWO SILT FENCES WHEN TRENCHING IS USED
RUNOFF
RUNOFF
NTS
BRIGHTLY COLOR MESH
CONSTRUCTION FENCING
ATTACHED WITH TWIST
WIRE CONNECTOR
EXISTING GRADE TO
REMAIN UNDISTURBED
TREE TO REMAIN
1" ANGLE IRON
CORNER POSTS, MAX.
10' O.C.
PLACE BARRICADES AT
DRIPLINE UNLESS OTHERWISE
INDICATED ON THE PLANS
M
IN
M
IN
TREE PROTECTION NOTES
1) PROTECTIVE BARRIERS SHALL BE CONSTRUCTED, AS NECESSARY, TO
PREVENT THE DESTRUCTION OR DAMAGING OF REGULATED TREES THAT
ARE LOCATED WITHIN 50 FEET OF ANY CONSTRUCTION ACTIVITY OR
STORAGE OF EQUIPMENT AND MATERIALS.
2) PROTECTIVE BARRIERS SHALL BE PLAINLY VISIBLE AND SHALL CREATE
A CONTINUOUS BOUNDARY AROUND TREES OR VEGETATION CLUSTERS IN
ORDER TO PREVENT ENCROACHMENT BY MACHINERY, VEHICLES OR
STORED MATERIALS.
3) NO TRENCHING ALLOWED WITHIN THE PROTECTIVE BARRIER ZONE.
HAND DIG TO INSTALL UTILITY IF APPROVED BY CITY MANAGER OR
DESIGNEE. WHERE ROOTS GREATER THAN ONE INCH IN DIAMETER ARE
DAMAGED OR EXPOSED, THEY SHALL BE CUT CLEANLY AND RE-COVERED
WITH SOIL WITHIN ONE HOUR OF DAMAGE OR EXPOSURE.
4) PROTECTIVE BARRIERS SHALL REMAIN IN PLACE AND INTACT UNTIL
SUCH TIME AS LANDSCAPE OPERATIONS BEGIN.
5) LANDSCAPE PREPARATION IN THE PROTECTED AREA SHALL BE LIMITED
TO SHALLOW DISCING OF THE AREA. DISCING SHALL BE LIMITED TO A
DEPTH OF 4 INCHES.
6) NO BUILDING MATERIALS, MACHINERY OR HARMFUL CHEMICALS SHALL
BE PLACED WITHIN PROTECTIVE BARRIERS.
7) THE AMERICAN NATIONAL STANDARDS INSTITUTE A-300 PART V:
MANAGEMENT OF TREES AND SHRUBS DURING SITE PLANNING, SITE
DEVELOPMENT, AND SITE CONSTRUCTION OR OTHER NATIONALLY
RECOGNIZED ARBORICULTURAL STANDARDS SHALL BE USED AS
GUIDELINES FOR TREE PROTECTION, PLANTING, PRUNING AND CARE
DURING DEVELOPMENT AND CONSTRUCTION.
NTS
3000 PSI CONCRETE
SAWCUT @ 10' O.C.
GRASS PARKING
6"
ASPHALT PAVEMENT
5" CONCRETE, 4000 PSI
CONTRACTION JOINTS @ 12' O/C (SEAL JOINT)
EXPANSION JOINTS @ 100' O/C
NOTE: CONCRETE PAVEMENT & JOINTS SHALL
NTS
BE CONSTRUCTED TO FC & PA STANDARDS.
6" STABILIZED BASE, LBR 40
NTS
4" NO. 57 STONE (UNYIELDING)
PERMEABLE WEED BARRIER
12" UNYIELDING
SUBGRADE1
DITCH WIDTH (w) + 2'
REPLACEMENT STRUCTURAL
NTS
18"
COURSE AND FRICTION COURSE
8" LIMEROCK BASE
SEE NOTE #3
EXISTING ASPHALT
PAVEMENT
REPLACEMENT BASE
12"12"
VARIES
DITCH WIDTH (w)
STAGE #2 BACKFILL *
SEE NOTES
SEE NOTES
NOTES:
1. IN STAGE #1, CONSTRUCT COMPACTED FILL BENEATH THE HAUNCHES OF THE PIPE, USING MECHANICAL TAMPS SUITABLE FOR THIS PURPOSE. THIS COMPACTION APPLIES TO THE MATERIAL PLACED BENEATH THE HAUNCHES OF THE PIPE AND
ABOVE ANY BEDDING.
2. IN STAGE #2, CONSTRUCT COMPACTED FILL ALONG THE SIDES OF THE PIPE AND UP TO THE BOTTOM OF THE BASE, WITH THE UPPER 12" RECEIVING TYPE B STABILIZATION. IN LIEU OF TYPE B STABILIZATION, THE CONTRACTOR MAY CONSTRUCT
USING OPTIONAL BASE GROUP 3.
3. NEW 8" LIMEROCK BASE SHALL BE COMPACTED TO NOT LESS THAN 98% OF MAX DENSITY AS SPECIFIED BY THE FLORIDA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATION 200-7.2. THE WIDTH OF THE LIMEROCK BASE SHALL BE THE
WIDTH OF THE PIPE TRENCH PLUS 18" ON BOTH SIDES SEE DETAIL.
4. UNLESS OTHERWISE SPECIFIED, MATERIALS AND METHODS OF OPERATION REQUIRED TO INSTALL NEW AND REPLACEMENT PAVEMENT SHALL BE IN ACCORDANCE WITH THE LATEST APPLICABLE REQUIREMENTS OF THE FLORIDA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION.
5. PAVEMENT SHALL BE REMOVED TO NEATLY SAWED STRAIGHT EDGES.
6. THE TYPE AND THICKNESS OF THE NEW SURFACE MATERIAL SHALL BE CONSISTENT WITH THAT OF THE EXISTING SURFACE, BUT IN ALL CASES SHALL MEET THE MINIMUM STANDARDS ESTABLISHED BY THE PLANS AND SPECIFICATIONS.
7. THE BACKFILLING AND PAVEMENT REPLACEMENT MUST BE DONE IN ACCORDANCE WITH FDOT INDEX 125-001.
STAGE #1 BACKFILL *
C0.01
GENERAL NOTES AND
DETAILS
NTS
12"
STORM
ELBOW
WYE
PVC STORM
RISER
PVC
STORM
WATER TIGHT
SEAL
EXTEND EXISTING
DOWNSPOUT WITH
ELBOW
EXISTING
DOWNSPOUT
NTS
TOP ZONE
COVER ZONE
LOWEST ZONE
BEDDING ZONE
1.