B08_Attachment_1_SOW.pdf

PDF 241 KB Posted

Attached to
Fire Equipment Testing, Maintenance, and Inspect Federal contract opportunity
Solicitation number
140P8524Q0043
Issued by
Department of the Interior National Park Service

About this file

This document is a Statement of Work (SOW) for a Request for Quotation (RFQ) to provide fire equipment inspection, testing, and maintenance services for Yosemite National Park. The objective is to have a contractor perform annual certification and maintenance on the park's fire equipment, including 28 self-contained breathing apparatus (SCBA) units, 17 hydraulic extrication tools, and 2 SCBA air compressors. The work is to be performed at the Yosemite Valley and Wawona fire stations within 30 days of contract award. Upon completion, the contractor will provide certification documents and reports detailing any needed future repairs. The related federal contract opportunity is a 100% small business set-aside solicitation with a NAICS code of 811310 and a $12.5 million size standard. Quotes are due by 5:00 PM PT on April 23, 2024, and the government will select the most advantageous offer based on price, schedule, and past performance.

View the file

Other files for this federal contract opportunity

Other files attached to Fire Equipment Testing, Maintenance, and Inspect, newest first.
File Type Posted
Sol_140P8524Q0043_Amd_0001.pdf PDF
B09_Amd_0001_Questions_and_Answers_0001.pdf PDF
B08_Attachment_2_DOL_Wage_Determination.pdf PDF
Sol_140P8524Q0043.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RFQ # 140P8524Q0043 - Fire Equipment Services Page 1 of 1

Statement of Work

FIRE EQUIPMENT INSPECTION, TESTING, AND MAINTENANCE

Yosemite National Park Objective:

Yosemite National Park has a requirement for fire equipment inspection, testing, and maintenance.

Background:

Yosemite National Park provides a variety of emergency response within the park boundary, including response to structure fire incidents. Specialized equipment used for structure fire operations requires annual certification to meet agency and national policies as well as comply with the A123 audit.

Requirement:

In accordance with The National Fire Protection Association (NFPA) 1852 and applicable manufacturer’s instructions, the Contractor shall provide all necessary equipment, supplies, and certified technicians to perform required annual inspection, testing, maintenance, and certification on the following fire systems:

• Manufacturer and Parts Number: MSA G1 Self Contained Breathing Apparatus (SBCA) (Quantity: 28 units)

• Battery Powered Hydraulic Extrication Tools, including the following:

o Manufacturer and Parts Number: Hurst SC358 Combi (Quantity: 5 units) o Manufacturer and Parts Number: Hurst SP555 E2 Spreader (Quantity: 4 units) o Manufacturer and Parts Number: Hurst S799 E2 Cutter (Quantity: 4 units) o Manufacturer and Parts Number: Hurst R421 E2 Ram (Quantity: 4 units)

• Manufacturer and Parks Number: Eagle Air Talon BAC Self Contained Breathing Apparatus (SCBA) Air Compressors (Quantity: 2 units)

Places of Performance:

The work will occur at two locations in Yosemite National Park:

• Yosemite Valley Fire Station, 9034 Lost Arrow Drive, Yosemite, CA 95389

• Wawona Fire Station, 2540 Wawona District Circle, Wawona, CA 95389

Period of Performance:

Units shall be serviced within 30 days of award.

Deliverables:

Upon completion of services, the contractor will provide the following deliverables:

• Each compressor will have an annual certification certificate and/or sticker.

• All SCBAs will be listed on an annual certification report; this report will also include any needed parts for future repairs.

• All hydraulic extrication tools will be listed in an annual certification report; this report will also include any needed parts for future repairs.

File details come from the government source that posted it. Updated .