B08_Attachment 0007_CERTIFIED TEST RESULT FOR PROCUREMENT Black Powder.pdf
PDF 94 KB Posted
- Attached to
- W519TC-25-Q-POWD Black Powder
- Solicitation number
- W519TC-25-Q-POWD-V2
About this file
This is a Certified Material Test Report for black powder procurement, specifically detailing technical specification requirements for material testing under MIL-DTL-223D specification. The document outlines comprehensive testing criteria that must be met, including requirements for fiberboard liner construction with precise parameters such as a 45-degree (±15 degrees) spiral winding angle, maximum 0.06-inch horizontal gaps between windings, and layers bonded with polyvinyl acetate resin adhesive. The test report must include detailed information like supplier name and address, purchase order number, material identification, quantity, and specific test results covering parameters such as materials, moisture, ash, specific gravity, apparent density, granulation, and pH.
The associated federal contract opportunity (Solicitation W519TC-25-Q-POWD-V2) is for Black Powder Class 3 and Class 6, issued by the Department of the Army Materiel Command Contracting Command at Rock Island Arsenal. The procurement is a Firm Fixed Price Contract using a Lowest Price Technically Acceptable (LPTA) approach, with a small business size standard of 750 under NAICS code 325920 (Explosives Manufacturing). Offers are due by 23 April 2025 at 1:00 PM Central Time, to be submitted electronically via email to specified contract specialists, with the goal of awarding a single contract for black powder procurement to be delivered to a facility in Crane, Indiana.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| B08_Attachment 0005_RFQ Questionnaire 26FEB2025.xlsx | XLSX spreadsheet | |
| B08_Attachment 0008_MIL-DTL-223D Black Powder.pdf | ||
| B08_Attachment 0002_Price Matrix 26FEB2025.xlsx | XLSX spreadsheet | |
| B08_Attachment 0006 Solicitation Provisions and Clauses.docx | DOCX document | |
| B08_Attachment 0003_FAR 52.204-24.docx | DOCX document | |
| B08_Attachment 0001_Purchase Description for Black Powder_Class 3 and 6.docx | DOCX document | |
| B08_Attachment 0004_FAR 52.212-3 Alt 1.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CERTIFIED MATERIAL TEST REPORT
For those material(s) identified below, a certified test report must be provided to the Government with each shipment. The test results contained on the certified test report(s) shall be adequate to determine compliance with all applicable requirements of the material specification(s) listed below. Availability of the certified test reports are in addition to other contract requirements and does not reduce or prejudice the Government's right to inspect supplies under other provisions of this contract. The test report(s) shall contain the following:
a. Name and address of suppliers.
b. Purchase order number.
c. Identification of all materials by specification, revision, amendment and dates, together with type, grade, size etc.
d. Quantity of each material.
e. Test results identified by reference to the applicable requirements:
1. Materials
2. Moisture
3. Ash
4. Specific Gravity
5. Apparent density
6. Granulation
7. Gritty or fibrous particles
8. Glaze finish
9. pH
10. Workmanship
f. Date, signature, and title of the authorized representative of the contractor that is attesting to the accuracy of test report content.
SPECIFICATION
MIL-DTL-223D
REQUIREMENT
SPECIFIED FOR (.030 INCH) NOMINAL THICKNESS.
3. FIBERBOARD LINER SHALL BE TIGHTLY AND SPIRALLY
WOUND. THE ANGLE OF SPIRAL
SHALL BE 45 ı# 15 DEGREES. LAYERS SHALL BE BONDED
TOGETHER WITH POLYVINYL
ACETATE RESIN ADHESIVE IAW COMMERICAL ITEM
DESCRIPTION ASTM D4317 OR A-A-1270
BETWEEN LAYERS. HORIZONTAL GAPS BETWEEN WINDINGS
SHALL BE 0.06 MAXIMUM.