B08_Attachment 0006_CERTIFIED TEST RESULT FOR PROCUREMENT Black Powder.pdf
PDF 94 KB Posted
- Solicitation number
- W519TC-25-Q-POWD_SS
About this file
This document is a Certified Material Test Report for black powder, specifying detailed testing and documentation requirements for materials supplied under MIL-DTL-223D military specification. The report mandates comprehensive test documentation for each shipment, requiring suppliers to provide a certified test report that includes supplier details, purchase order number, material identification, quantity, and specific test results covering parameters such as materials composition, moisture, ash, specific gravity, density, granulation, particle characteristics, glaze finish, pH, and workmanship. The document emphasizes that these test reports are in addition to standard contract inspection provisions and must include an authorized representative's signature attesting to the accuracy of the test results.
The specific technical requirements highlighted include a .030 inch nominal thickness for fiberboard liner, which must be tightly and spirally wound at a 45 ± 15 degree angle, with layers bonded together using polyvinyl acetate resin adhesive following ASTM D4317 or A-A-1270 standards. Horizontal gaps between windings are restricted to a maximum of 0.06 inches, indicating precise manufacturing specifications for the material's construction and assembly.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| B08_Attachment 0008_Justification for Sole Source (KO Signed).pdf | ||
| B08_Attachment 0007_MIL-DTL-223D.pdf | ||
| B08_Attachment 0003_FAR 52.204-24.docx | DOCX document | |
| B08_Attachment 0001_Purchase Description for Black Powder Class 3 and 6 13MAY25.docx | DOCX document | |
| B08_Attachment 0005_Solicitation Provisions and Clauses.docx | DOCX document | |
| B08_Attachment 0004_FAR 52.212-3 Alt 1.docx | DOCX document | |
| B08_Attachment 0002_Price Matrix 13MAY2025.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CERTIFIED MATERIAL TEST REPORT
For those material(s) identified below, a certified test report must be provided to the Government with each shipment. The test results contained on the certified test report(s) shall be adequate to determine compliance with all applicable requirements of the material specification(s) listed below. Availability of the certified test reports are in addition to other contract requirements and does not reduce or prejudice the Government's right to inspect supplies under other provisions of this contract. The test report(s) shall contain the following:
a. Name and address of suppliers.
b. Purchase order number.
c. Identification of all materials by specification, revision, amendment and dates, together with type, grade, size etc.
d. Quantity of each material.
e. Test results identified by reference to the applicable requirements:
1. Materials
2. Moisture
3. Ash
4. Specific Gravity
5. Apparent density
6. Granulation
7. Gritty or fibrous particles
8. Glaze finish
9. pH
10. Workmanship
f. Date, signature, and title of the authorized representative of the contractor that is attesting to the accuracy of test report content.
SPECIFICATION
MIL-DTL-223D
REQUIREMENT
SPECIFIED FOR (.030 INCH) NOMINAL THICKNESS.
3. FIBERBOARD LINER SHALL BE TIGHTLY AND SPIRALLY
WOUND. THE ANGLE OF SPIRAL
SHALL BE 45 ı# 15 DEGREES. LAYERS SHALL BE BONDED
TOGETHER WITH POLYVINYL
ACETATE RESIN ADHESIVE IAW COMMERICAL ITEM
DESCRIPTION ASTM D4317 OR A-A-1270
BETWEEN LAYERS. HORIZONTAL GAPS BETWEEN WINDINGS
SHALL BE 0.06 MAXIMUM.
File details come from the government source that posted it. Updated .