This document outlines salient characteristics for an industrial monitoring station and sensor system procurement. The system requires two industrial monitoring stations with specified hardware, software, and interface capabilities to support data acquisition and station control. The stations must interface with two spectrometry sensors for measuring nitrate and turbidity in river water applications, along with associated brush cleaning systems, extension cables, and software licenses. The related federal contract opportunity is for the procurement of these industrial monitoring systems to specifications provided for use by the Department of Interior US Geological Survey Office of Acquisitions and Grants.

View the file

Other files

File Type Posted
Sol_140G0124Q0041_Amd_0002.pdf PDF
Sol_140G0124Q0041_Amd_0001.pdf PDF
B08_ATCH_2_508_S24002.pdf PDF
Sol_140G0124Q0041.pdf PDF
B08_ATCH_3_FISMA_S24002.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Salient Characteristics Special Order S24002

INDUSTRIAL MONITORING STATION AND SENSOR SYSTEM

SALIENT CHARACTERISTICS:

System shall consist of a monitoring station, spectrometry sensor, software, and accessories.

2 EA. Industrial Monitoring Station:

1. Shall be a compact industrial terminal/controller for data acquisition and station control.

2. Shall include numerous input options capable of supporting and interfacing to a wide range of environmental sensors.

3. Shall be capable of being powered from a 12 VDC (nominal) power source.

4. Shall include Wi-Fi, Ethernet, and USB interfaces.

5. Shall include IoT (Internet of Things) and M2M (Machine to Machine) connectivity.

6. Shall include a 9” numerical/graphical, color touchscreen display.

7. Shall be capable of supporting sensor interfacing via RS-485, analog, digital, or SDI-12 inputs.

8. Shall be capable of transferring data via Modbus, RTU/TCP interface, analog outputs, or FTP file transfers.

9. Shall have alarm and triggering capability.

10. Shall have status indicating LED(s).

11. Shall have an Ingress Protection (IP) rating of at least IP65 or better.

12. Shall be capable of operating over a range of temperatures from at least -20 to 50o C.

13. Shall be capable of remote setup and operation.

14. Shall include features/facilities for mounting to a flat or vertical surface.

15. Shall include at least 2 GB of main memory and at least 16 GB of on-board memory.

16. Shall include at least 4 expansion slots for expansion and customization of I/O interfaces.

17. Shall be no larger than 11” x 8.5” x 4” and weigh no more than 10 lbs.

18. Shall include touch pen, mounting hardware and fasteners, and any applicable cable(s), or other components, for proper interconnection and operation of the system.

2 EA. Software License

19. Shall consist of a Linux OS embedded operating system software license.

2 EA. Monitoring Station System Software

20. Shall consist of monitoring station software capable of supporting at least 4 parameters with the following features and capabilities:

- station and sensor management tasks including initialization, configuration, event detection, sensor calibration,

- ability to setup multiple stations and configurations,

- data management, visualization, data reporting, and exporting of data,

- ability to view current sensor readings and logged data as well as sensor condition and performance,

- ability to view multiple sensor readings on a single screen,

- logging and tracking of maintenance performed including calibrations,

- quality assurance and quality control functions,

- automatic restart and continuation of measurement following power disruptions,

- ability to send SMS messages, Salient Characteristics Special Order S24002

- ability to initiate an alarm when detecting system irregularities,

- automatic adjustment of measuring and cleaning intervals based on pre-defined conditions.

21. Software shall be pre-installed on the monitoring station described above prior to delivery.

1 EA. Spectrometer Sensor:

22. Shall consist of a compact submersible spectrometer for measuring nitrate and turbidity/solids concentration in river water applications.

23. Shall use the UV-Vis spectrometry measurement principle with a range of 190 – 750 nm.

24. Shall operate form 12 VDC (nominal) power source.

25. Shall have a 35mm path length.

26. Shall have an Ingress Protection (IP) rating of at least IP68 or better.

27. Shall have a stainless-steel housing.

28. Shall have at least 8 GB of memory.

29. Shall weigh less than 8 lbs.

30. Shall be capable of 10 Hz measurement interval.

31. Shall include built-in tilt and rotation sensors.

32. Shall be capable of being automatically cleaned with compressed air or an attached brush.

33. Shall be capable of operating over a range of temperatures from at least 0 to 50o C.

34. Shall include a 15m (50’) fixed cable.

2 EA. Brush for Spectrometer:

35. Shall be compatible with spectrometer described above.

36. Shall be compatible with a 35mm path length.

37. Shall consist of a submersible brush assembly than can be attached to the spectrometer and prevent debris, fouling, etc. from the optical measurement lens.

1 EA. Extension Cable for Spectrometer:

1. Shall consist of a 20M extension cable for the spectrometry sensor described above.