This document is a set of Salient Characteristics for a federal contract opportunity for Digital Temperature Cables and Accessories. The key requirements include:

7 ea. Digital Temperature Cables with 13 temperature sensors along a 7.1m cable, capable of operating from -50 to 120°C with +/- 0.1°C accuracy, and interfacing with RS-232/RS-485/SDI-12 data loggers. 7 ea. SDI Communication Interfaces compatible with the sensor cables, 1 ea. Rigid Temperature Probe with 19 sensors along a 3.3m length, and 1 ea. Portable Compact Data Logger with 32MB storage and wireless Bluetooth.

The related federal contract opportunity, Solicitation Number 140G0124Q0293, is for the delivery of these Digital Temperature Cables and Accessories to the U.S. Geological Colorado Water Science Center in Denver, CO within 30 days. This is a total small business set-aside with a NAICS code of 334513 and a size standard of 750 employees. The Request for Quote is due on or about 9/09/2024 and the anticipated award date is 09/19/2024.

View the file

Other files

File Type Posted
Sol_140G0124Q0293.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Salient Characteristics

S24144

Digital Temperature Cables and Accessories

SALIENT CHARACTERISTICS:

7 ea. Digital Temperature Cable:

1. Shall consist of a flexible digital cable with embedded temperature sensors for temperature profiling applications.

2. Cable shall be 7.1m (23.29) ft in overall length with 4.5m (14.76 ft.) of lead cable (w/o sensors), and 2.6m (8.53 ft.) of sensors.

3. Shall include 13 ea. temperature sensors spaced at 20 cm (0.656 ft.) intervals.

4. Shall terminate with bare wire (leads).

5. Sensors shall start from the opposite end as the bare leads.

6. Shall include white heat shrink.

7. Shall be capable of operating over a temperature range from at least -50 to 120o C.

8. Shall have a measurement accuracy of +/- 0.1o C, or better over a range of at least -10 to 30o C.

9. Cable shall include a low-temperature polyurethane jacket with an integrated reinforcing member to protect the cable against bending or stretching forces.

10. Shall have an Ingress Protection (IP) rating of IP68 or better.

11. Sensor bodies/molds shall be flexible and no larger than 0.5 inches in size/diameter.

12. Cable shall include digital signal conversion in order to interface with RS-232/RS-485/SDI-12 data logging devices.

13. Shall be capable of a digital output and interfacing with the data logger described below.

7 ea. SDI Communication Interface:

14. Shall consist of a compact, DIN mountable, interface device capable of SDI-12 communications.

15. Shall be compatible with the sensor cable described above.

16. Shall include “spring-cage” style terminals.

17. Shall be cable of being powered from a 12 VDC (nominal) power source.

18. Shall include electrostatic discharge protection features.

19. Shall be capable of operating over a temperature range from at least -40 to 80o C.

20. Shall be no larger than 4” x 4.5” x 0.9” and weigh no more than 0.2 lbs.

1 ea. Rigid Temperature Probe:

21. Shall consist of a digital, rigid, temperature probe that is waterproof and resistant to frost jacking forces.

22. Probe shall be 3.3m (10.82) ft in overall length with 1.5m (4.92 ft.) of lead cable (w/o sensors), and

1.8m (5.90 ft.) of sensors.

23. Shall include 19 ea. temperature sensors spaced at 10 cm (0.328 ft.) intervals.

24. Shall be encased in lightweight stainless steel that is no larger than 0.5” in diameter.

25. Shall be capable of operating over a temperature range from at least -50 to 120o C.

26. Shall be capable of operating in wet, dry, or frozen field conditions.

27. Shall be capable of a digital output and interfacing with the data logger described below.

Salient Characteristics

S24144

1 ea. Data Logger:

28. Shall consist of a portable, compact data logger with wireless Bluetooth communications.

29. Shall be compatible with the temperature sensors and communication interface described above.

30. Shall include at least 32MB of non-volatile flash data storage.

31. Shall have a capacity of storing at least 5 million samples.

32. Shall be capable of being powered by a replaceable, non-rechargeable, user-furnished, lithium battery.

33. Shall be capable of operating over a temperature range from at least -40 to 80o C.

34. Shall include a real-time clock.

35. Shall include built-in self-diagnostics and logger health monitoring features.

36. Shall be capable of internal humidity and battery monitoring.

37. Shall be no larger than 7.5” x 2.75” and weigh no more than 1.lb.