This document is a Salient Characteristics specification sheet for a Portable Liquid Sampler to be used for water quality data collection at gaging stations located near lakes, rivers, and streams throughout the United States. The equipment must include an integrated controller and pump capable of supporting dual bottle configurations: 24 polypropylene bottles (1-liter each) and 24 glass bottles (350 ml each). The sampler shall be programmable to accommodate varying sample frequencies and volumes, feature a built-in SDI-12 interface with window, and include an adjustable air purge capability.
Technical requirements specify a minimum lift capability of 28 feet, an IP67 enclosure rating, at least 512KB of memory, and operation from external 12 VDC power. The equipment must include a liquid detection sensor, 3/8-inch tube intake, 3/8-inch tubing coupler, bottle retaining ring, and a minimum 6-foot-long cable for external 12 VDC power connection. These specifications establish the minimum performance and component standards required for the portable liquid sampling equipment.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sol_140G0126Q0120.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics
Portable Liquid Sampler
This equipment will be used to collect water quality samples from various data collection gaging stations located near lakes, rivers, and streams all over the US.
Salient Features for Sampler
Shall include a controller and pump Shall support bottle configurations of 1-liter polypropylene bottles (24 each) and 350 ml glass bottles (24 each) Shall be programmable to allow for different sample frequencies and sample volumes Shall have a build-in SDI-12 interface with window Shall include an adjustable air purge feature Lift capability shall be at least 28 feet Enclosure shall have an IP rating of at least IP67 Shall include at least 512KB of memory Shall operate from external 12 VDC power Shall include a liquid detection sensor Shall include a 3/8-inch tube intake Shall include 3/8-inch tubing coupler Shall include cable for external 12 VDC power connection; min 6-foot long Shall include bottle retaining ring