This document is a Salient Characteristics specification for Single-Axis Tilt Sensors (Inclinometers) with the contract number S25078. The specification requires 5 single-axis tilt sensors and 5 corresponding connector cables with precise technical requirements. Key sensor specifications include a solid-state design with +/- 60-degree tilt limit, 0-5 VDC output, 12 VDC power operation, IP66 sealed housing, -40 to 80°C operating temperature range, and RoHS compliance. The sensors must be compact (no larger than 3.75" x 1.75" x 1.6") and have specific performance characteristics such as +/- 0.5 degree transverse axis misalignment and 0.02% non-linearity. The accompanying 80-foot connector cables must be compatible with the sensors and include stripped/tinned open lead wires on one end.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sol_140G0126Q0005.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics
S25078
Single-Axis Tilt Sensors (Inclinometers)
SALIENT CHARACTERISTICS:
5 ea. Single-Axis Tilt Sensor:
1. Shall consist of a self-contained, solid state, single-axis, analog tilt sensor (inclinometer).
2. Shall include a fluid dampening mechanism.
3. Shall have a tilt limit input range of +/- 60o.
4. Shall have a full range output of 0-5 VDC.
5. Shall be capable of operating from an external 12 VDC (nominal) power source.
6. Shall include a sealed housing with a cable connector, with an Ingress Protection (IP) rating of IP66, or better.
7. Transverse axis misalignment (o max) shall be +/- 0.5 or less.
8. Shall have a non-linearity (% FRO max)2 rating of 0.02% or less.
9. Shall be capable of operating over a temperature range from at least -40 to 80o C.
10. Shall be Restriction of Hazardous Substances (RoHS) compliant.
11. Shall be no larger than 3.75” x 1.75” x 1.6”.\
5 ea. Connector Cable:
12. Shall be compatible with the tilt sensor described above.
13. Shall consist of an 80 ft. power/data cable with a compatible mating connector.
14. Shall include stripped/tinned open lead wires on one end.