This document is a Salient Characteristics specification for a Non-Contact Radar Water Level Sensor for the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility. The specification details precise technical requirements for water level measurement sensors, specifically seeking a device like the VegaPuls C 23 Radar Water Level Sensor or an equivalent model with 80 GHz measurement frequency technology.

The sensor must meet stringent performance criteria, including a measurement uncertainty of no more than 0.01 ft or 0.1% of indicated reading, a measurement range of 0 to 30m, a narrow 4° beam angle, and an operating temperature range of -40° to 60°C. Additional mandatory features include 12 VDC power source compatibility, an SDI-12 interface, IP66/68 mechanical rating, integrated Bluetooth communication, a 15 ft communication/power cable, and an optional mounting bracket. These sensors will be used for water level measurements at data collection sites nationwide.

View the file

Other files

File Type Posted
Sol_140G0125Q0193.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Salient Characteristics

Non-Contact Radar (Model VegaPuls C 23 Radar Water Level Sensor or equal)

The USGS Hydrologic Instrumentation Facility needs to purchase non-contact radar water level sensors with 80 GHz measurement frequency technology. This equipment will be used for measuring water levels at data collections sites all over the country.

Non-Contact Radar

Shall meet USGS requirements for stage accuracy measurements and shall measure stage with a total measurement uncertainty of no more than 0.01 ft. or 0.1% of indicated reading, whichever is larger over a temperature range of at least -40° to 60°C.

Shall be capable of a measurement range up to at least 0 to 30m (0 to 98 feet).

Shall use 80 GHz measurement frequency technology.

Shall have a beam angle that is no larger than 4o.

Shall be capable of an operating temperature range of at least -40° to 60°C.

Shall be powered from a 12 VDC (nominal) power source.

Shall include an SDI-12 interface.

Shall have a mechanical IP rating of at least IP66/68.

Shall have an integrated Bluetooth communication interface.

Shall include an integral SDI-12 communication/power cable that is at least 15 ft. long.

Shall have an option for a mounting bracket.