B01 - Attachment 0001 Drawing 9243 rev F.pdf
PDF 257 KB Posted
- Attached to
- 48x48" SIDEBOARD PALLETS Federal contract opportunity
- Solicitation number
- W519TC23QPLTS
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W519TC23QPLTS 48x48 Sideboard Pallets_QAs_31MAY2023.xlsx | XLSX spreadsheet | |
| W519TC23QPLTS 48x48 Sideboard Pallets_QAs_23MAY2023.xlsx | XLSX spreadsheet | |
| B01 - Attachment 0004 FAR 52.212-3 Alt 1.docx | DOCX document | |
| B01 - Attachment 0002 - Price Sheet.xlsx | XLSX spreadsheet | |
| B01 - Attachment 0003 FAR 52.204-24.docx | DOCX document | |
| B01 - Attachment 0005 Provisions and Clauses.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWING REVIEW CHECKLIST
Questions to be answered by Design Engineer:
Y N NA
1. Is there an alternate tool or design that could be used to perform this task?
if yes, please explain what and why not used (i.e., cost, time, etc.).
2. Are cracks, voids, weld seams, or other areas where explosives could accumulate eliminated if it is used in and explosive atmosphere?
3. Are all pinch points eliminated so that neither explosive can be pinched or personnel injured?
4. Is the material specified appropriate for explosive atmosphere if used in this environment?
5. Are all Electrical components properly rated for the type of location where it will be used?
7. Are all commercial components specified for use adequately rated for the type of location where it will be used?
8. Does the item have adequate safety interlocks designed (i.e., two-handed controls, etc.)?
9. Is the item strong enough to perform at 150% of intended use (i.e., weight, pressure, etc.)?
10. Is the item designed with ergonomic considerations (i.e., proper height, ?
repetitive movements, proper gripping, line of sight, strength required to operate?
11. Is the item designed for minimal maintenance and does it provide easy access if maintenance is required?
12. Is the item designed to allow lockout/tag out when maintenance is performed?
13. If required, can the item be decontaminated without destroying its intended use?
14. If required, had adequate special fire protection been built into the design?
15. Has the item been designed to interact with other components within the system?
Signature
6. Is adequate guarding/shielding designed into the item?
16. Distribution Statment: A B C D E F
A
CAAA Form 702-168 Nov. 2019
REVISIONS
LTR DESCRIPTION DATE DATE
NOMENCLATURE MATERIAL
TITLE
ITEM
NO.
NO.
REQ'D
BREAK ALL
SHARP EDGES
UNLESS OTHERWISE NOTED, TOLERANCES ARE:
DECIMALS: .XXX ± .005, .XX ± .01, .X ± .1 ANGLES: ± 30'
FOR DRAWING NO.
CHECKED BY
FABRICATION
SAFETY
APPROVAL
DATE
DATE
DATE
DATE
DRAWN BY
DATE
C SCALE DWG. NO. SHEET
OF
CRANE ARMY AMMUNITION ACTIVITY
ENGINEERING DIVISION
7 1/16
14 3/16
21 1/4
28 5/16
35 7/16
14 1/8
28 3/8
15 1/2
15 1/2
1 1/4
9 3/4
2 X 4 X 48" LONG
1 X 6 X 48" LONG
2 X 12 X 48" LONG
2 X 12 X 45" LONG
2 SEE
NOTE
NOTE:
1. NORMAL ACCEPTED FASTENING METHODS TO
BE USED IN CONSTRUCTION OF PALLET.
2. MATERIAL TO BE #2 CONSTRUCTION GRADE
LUMBER, OR BETTER
4. STRAPPING USED TO BE .035" THK. GALV.
STL. - 1900 LB PULL TEST. QQ-5-781
ASTM 03953-91
3. TOLERANCE TO BE ± 1/4"
*STRAPPING TO BE SECURED WITH
STAPLES TO PREVENT SLIPPAGE.
USE 16 GAGE - 3/4" TO 7/8" LONG
STAPLES. 3 PER SIDE PER STRAP.
FIRST USED FOR VARIOUS STORAGE OPERATIONS AT BUILDINGS 174, 69, STORAGE, ETC. RJ WILSON
31 AUG 1994 N.T.S. 9243 1 1
PALLET WITH SIDEBOARDS
FOR STORAGE - 48" X 48"
A
B
C
D
E
ADDED STRAPPING
DELETED SLOTS IN 2x4'S
RELOCATED STRAPPING
ADDED STAPLE AND
STRAPPING SPECS.
ELIMINATE BANDING
PARALLEL ACROSS ITEM #3
RJW
RJW
RJW
RJW
11/15/94
12/8/94
1/10/95
2/5/97
11/2/1112 GA STAPLE TO 16 GA DRB
3/4" METAL STRAPPING (2EA)
SECURED TIGHTLY AROUND
OUTSIDE OF SIDEWALLS*
3/4" METAL STRAPPING (2 EA) OVER
THE TOP, DOWN SIDES AND UNDER THE
TOP SLATES OF PALLET - SECURED TIGHTLY*
STAPLES
DISTRIBUTION STATEMENT A
ADDED DIST. A NOTEF 7/25/22BJE
| Sheet 1 |
| Views |
| new_view_1 |
| right_2 |
| bottom_3 |
| Check Box1: Off | |
| Check Box2: Yes | |
| Check Box3: Off | |
| Check Box4: Off | |
| Check Box5: Off | |
| Check Box6: Yes | |
| Check Box7: Yes | |
| Check Box8: Off | |
| Check Box9: Off | |
| Check Box10: Yes | |
| Check Box11: Off | |
| Check Box12: Off | |
| Check Box13: Off | |
| Check Box14: Off | |
| Check Box15: Yes | |
| Check Box16: Yes | |
| Check Box17: Off | |
| Check Box18: Off | |
| Check Box19: Yes | |
| Check Box20: Off | |
| Check Box21: Off | |
| Check Box22: Off | |
| Check Box23: Off | |
| Check Box24: Yes | |
| Check Box25: Yes | |
| Check Box26: Off | |
| Check Box27: Off | |
| Check Box28: Yes | |
| Check Box29: Off | |
| Check Box30: Off | |
| Check Box31: Yes | |
| Check Box32: Off | |
| Check Box33: Off | |
| Check Box34: Off | |
| Check Box35: Off | |
| Check Box36: Yes | |
| Check Box37: Yes | |
| Check Box38: Off | |
| Check Box39: Off | |
| Check Box40: Off | |
| Check Box41: Off | |
| Check Box42: Yes | |
| Check Box43: Off | |
| Check Box44: Off | |
| Check Box45: Yes | |
| Check Box60: Yes | |
| Check Box61: Off | |
| Check Box62: Off | |
| Check Box63: Yes | |
| Check Box64: Off | |
| Check Box65: Off | |
| Check Box66: Off | |
| Check Box67: Off | |
| Check Box46: Off | |
| 2022-07-25T07:18:18-0400 | |
| ECKERT.BENJAMIN.J.1596555302 |
File details come from the government source that posted it. Updated .