About this file

This document is a Sources Sought notice for a potential contract for Turbine Runner Cavitation Repair at the Grand Coulee Dam and Power Plant in Washington. The Bureau of Reclamation is conducting market research to assess the capabilities and qualifications of interested small business firms. The principal components of the work include an assessment of cavitation damage, grinding and welding to repair the turbine runners, and related mobilization and demobilization. The estimated value of the potential 5-year requirements contract is between $5-10 million, though no guarantee of orders is provided. Responses to this notice are requested by November 12, 2024 and should include company information, capabilities, product details, and past performance. No solicitation is currently available, and drawings will only be provided to those who complete a non-disclosure agreement. The potential procurement opportunity has a North American Industry Classification System (NAICS) code of 238190 (Other Foundation, Structure, and Building Exterior Contractors).

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought -- 140R10-25-R-0001 Turbine Runners Cavitation Repair, Nate Washington Power Plant, Grand Coulee Dam, Washington

This is a Sources Sought announcement only. THIS IS NOT A REQUEST FOR PROPOSALS, QUOTATIONS OR BIDS, NOR A PROPOSED SYNOPSIS OF A PROPOSED CONTRACT

ACTION UNDER FAR SUBPART 5.2 and no contract shall be awarded from this notice. No reimbursement will be made for any costs associated with providing information in response to this Sources Sought or any follow up information requests. No solicitation is currently available.

Draft specifications are subject to change. This market research is to gain knowledge of interest, capabilities, and qualifications of interested Small Business firms. Responses to this Sources

Sought will shape the acquisition strategy in developing a competitive requirement.

The Columbia-Pacific Northwest (CPN) Regional Office of the U.S. Bureau of Reclamation is conducting market research for a Turbine Runners Cavitation Repair construction contract. The work location will be at the Grand Coulee Dam and Power Plant, approximately 90 miles west of

Spokane, Washington, and 60 miles north of Moses Lake, Washington, in Okanogan County, near the city of Coulee Dam.

The principal components of work will be:

A. Turbine Runner Cavitation Repair – Grand Coulee Dam & Power Plant; Coulee Dam, Washington. Six (6) G19, G20, G21, G22, G23, and G24 hydro-electric turbines.

1 *Assessment of cavitation damage to the generator runners

2 *Estimation of time and welding material needed to repair cavitation damage

3 Grinding to runners in preparation for repair

4 Welding to repair runners

5 Grinding to runners to restore contours of the blades

6 Pre-mobilization site meeting, mobilization, demobilization

NOTES TO ABOVE:

*1. Damage assessment will be conducted by the Government and communicated to the contractor both ahead of time for material ordering and initially upon on-site meetings and mobilization.

*2. Timeframe of cavitation repair (i.e. the window) is set by Government due to maintenance outages. Contractor will manage their schedule within Government constraints to meet repair deadlines.

The turbine runners which may be contracted for repair work per this specification are those in units G-19 through G-24 in the Grand Coulee Third Powerplant (TPP).

1. The phrase “turbine runner” includes the crown, outer ring, hub, air vents and blades, which make up the “runner” proper, as well as the top part of the draft tube discharge ring

(immediately below the runner). Each Grand Coulee turbine contains 13 blades (also called

“buckets” or “vanes”).

2. The Grand Coulee G-19 through G-21 units are equipped with 820,000 HP Francis-type turbines, designed by Dominion Engineering Works, Ltd., and manufactured by Williamette

Nate Washington Power Plant, Grand Coulee Dam, Washington

Iron and Steel Co. The runner throat diameter is 34 feet. The base metal of the runner assembly is cast steel, per ASTM A 216, Grade WCB. The original stainless-steel overlay was accomplished using alloy 308L.

3. The Grand Coulee G-22 through G-24 units are equipped with 960,000 HP Francis-type turbines, designed and manufactured by Allis-Chalmers. The runner throat diameter is 32 feet. The base metal of the crown and vanes (blades are cast steel, per ASTM A 216, Grade

WCC. The base metal of the runner band is steel, per ASTM A 516, Grade 70.

The Grand Coulee turbines have been in service since the mid-1970’s and have each gone through several major overhauls. Each has had different work crews and varying amounts of time to work with. Thus, no two units are in the same condition. Most of the runner is carbon steel, but a significant amount of stainless steel exists, from initial construction and previous repair areas.

Previously applied protective coatings consisted of primer and various kinds of epoxy paints.

Several turbines were coated with a zinc-rich primer.

The turbine types have noticeably different properties and characteristics with respect to the nature of damage seen:

1. On Grand Coulee units G-19 through G-21, cavitation damage is mostly seen as large

(approximately 6” wide by 12” long), eroded cavities on the lower pressure side of the blade, where it meets with the outer runner ring. These cavities are close to the leading edge (within a few feet) and can be several inches in depth. Some areas exhibit cavitation-enhanced corrosion (severe surface pitting, with a porous appearance like some kinds of cheese). Although these units are not known for having cracks in the blades, some have been found in the past.

2. On Grand Coulee units G-22 through G-24, damage is mostly seen as cavitation enhanced corrosion in the crown area. Several of the units have already been clad with stainless steel in the most troublesome areas. The low- pressure side wall of many of the blades have severe surface pitting that covers a large surface area. The leading edge of most of the blades exhibit corrosion erosion. These units have historically had cracks along the lower leading edge of the blade, as well as the upper and lower trailing edges.

B. The magnitude for this construction project is between $5,000,000 and $10,000,000 for the term of this five (5) year requirements contract; however, no guarantee is made for orders.

Sources are being sought for firms with a North American Industry Classification System (NAICS) code 238190 (Other Foundation, Structure, and Building Exterior Contractors), PSC 2ZKA and with a Small Business Size Standard of $19.0 million. NAICS code 238190 is not currently identified on the list of codes for Women Owned Small Businesses (WOSB). Small Business, 8(a), Woman Owned Small Business, Service-Disabled Veteran Owned Small Business, HUBZone and

Indian Small Business Economic Enterprise (ISBEE) contractor sources are highly encouraged to respond to this Sources Sought notice. After review of the responses to this announcement and if the Government still plans to proceed with this project; a separate solicitation announcement will be published on www.sam.gov. Responses to this announcement are not an adequate response to any future solicitation announcement.

Nate Washington Power Plant, Grand Coulee Dam, Washington

Responses are requested with the following information and shall not exceed a total of 10

(ten) pages.

Please provide the following information:

1. Contact information: Name, address, SAM.gov UEI number, and points of contact with telephone numbers and e-mail addresses.

2. Business Size/ Classification (based on NAICS 238190): Please indicate the business size and classification of your company to include any/all additional designations as Small Business, HUBZone, Woman Owned Small Business, Service-Disabled Veteran Owned Small Business, 8(a), or Indian Small Business Economic Enterprise (ISBEE) shall be clearly indicated in the submission.

3. Capabilities Statement: Description of capabilities to perform construction as described above and project experience demonstrating relevant experience similar to those described in the principal components of Turbine Runner Cavitation repair work.

4. Products: Identify the product country of manufacture and provide lead time estimates.

5. Past Performance/experience: Provide contracts of similar scopes of work or construction contracts, briefly describe no more than three (3) contracts (or specific task orders) completed within the past five years of the issue date of this Sources Sought notice. The past performance information shall include project title, location, general description of the construction to demonstrate relevance to the proposed project, the Offerors’ role, dollar value of contract, and name of the company, agency, or government entity for which the work was performed. If submitting past performance/experience on a project in the role of a subcontractor, include the

Prime Contractor’s name and a quantifiable amount (percentage) of the project your company contributed to the overall scope of work.

NO RESPONSES WILL BE ACCEPTED BY FAX.

Responses will not be returned. Telephonic responses will not be honored. Please respond by email only. Send responses to the Contract Specialist, Bill Roberts, at wroberts@usbr.gov

Responses will be accepted until 5:00 PM Mountain Time on Tuesday, 12 November 2024.

**Drawings are not currently available. However, once available interested individuals will need to complete a non-disclosure agreement (NDA) form. Drawings will not be provided unless an NDA is completed. Please contact Bill Roberts at wroberts@usbr.gov to request an NDA form** mailto:wroberts@usbr.gov