This document outlines office space requirements for the Bureau of Alcohol, Tobacco, Firearms and Explosives (ATF). It specifies various types of office spaces including headquarters offices, division offices, field offices, satellite offices, and flex office spaces. It provides details on location preferences, square footage needs, security requirements, finishes, partitions, doors, hardware, and other specifications. Required spaces include a secure foyer, LAN room, division conference room, conference room, supply room, mail and copy room, polygraph examination room, polygraph office, breakroom, training room, secure file room, interview room, defendant processing room, and secured storage. The document includes exhibits with additional specifications such as personnel security requests, wall and partition types, security symbols, electronic controls, armor, doors, windows, and furnishings.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LAW ENFORCEMENT

SENSITIVE

TENANT OFFICE

SPACE REQUIREMENTS

Issued August 3, 2017

TABLE OF CONTENTS

DESCRIPTION

A. OFFICE REQUIREMENTS

B. DESIGN AND CONSTRUCTION REQUIREMENTS

C. ABOVE STANDARD REQUIREMENTS

D. EXHIBITS

LAW ENFORCEMENT SENSITIVE

A. OFFICE REQUIREMENTS

The following is an overview of the Bureau of Alcohol, Tobacco, Firearm and Explosives’ (TENANT’s) Office requirements. Offices at TENANT can be classified under the following:

Headquarter Offices, Division Offices, Field Offices, Satellite Offices, and Flex-Office Space. Office locations are preferred in Class A office buildings while Flex-Office Spaces are usually located at light industrial/warehouse facilities. Descriptions of these basic requirements are noted in the following sections.

1. OFFICES

BUILDING LOCATION: The safety and security of TENANT employees, contractors and others employed by TENANT is our primary concern. Our preference is to locate TENANT Offices in Federal buildings when space is available and the building perimeter security is at Department of Justice Level IV or General Services Administration Level D. I f office space is located in a multi-story building, occupancy of entire floors is preferable to partial floor occupancy, additionally occupancy should be above the first floor and below the top floor. Light industrial and warehouse space is excluded from this restriction.

a. CRITERIA THAT ELIMINATES FEDERAL BUILDINGS FROM CONSIDERATION FOR

NEW OFFICE SPACE:

i. Proposed Federal building is not classified as a Department of Justice (DOJ) Level IV or above.

ii. Proposed Federal building is at least a DOJ Level IV, but houses immigration, probation, public defenders, and/or social services offices and does not have a separate entrance, elevator and parking facility for TENANT personnel and clientele.

iii. The only available office space in the proposed Federal building has immigration, probation, public defenders, and/or social services offices on the same floor.

iv. Proposed Federal building houses a day care facility.

v. Proposed Federal building cannot or will not accommodate secured parking for TENANT official vehicles. Parking spaces cannot be in a shared lot with buildings that house Public Defenders Offices.

b. CRITERIA THAT ELIMINATES COMMERCIAL SPACE FROM CONSIDERATION FOR

NEW OFFICE SPACE:

i. Proposed office space is on the first floor or below the first floor of the building.

ii. Proposed office space is on the top floor of the building and rooftop access is within the space.

iii. Proposed office space is inside a shopping mall or shopping center.

iv. Proposed building houses day care facilities, abortion clinics, mental health clinics, or drug rehabilitation clinics, immigration, probations, public defenders, and/or social services (including but not limited to: Social Security Administration (SSA) and Department of Health and Human Services (HHS)) within the building.

v. Proposed building will not or cannot accommodate secured parking for TENANT official vehicles at this facility.

vi. Proposed building or parking facility is within 1,000 feet of agencies or tenants identified in

iv. Above.

vii. Proposed building is within 1,000 feet of residential areas, places of worship, schools, hospitals, prisons, abortion clinics, mental health clinics, drug rehabilitation clinics and/or day care facilities.

viii. Proposed office space is located in a high crime area or an area that will necessitate more extensive and stringent building security than a generally progressive and alert neighborhood with a low crime rate.

ix. Any exceptions or variances to the above listed criteria must be approved in writing, by the Chief, Physical Security Programs Branch.

If TENANT cannot find a building within the central business district (see Executive Order 12072), which satisfies our security requirements, then TENANT must be allowed to expand the delineated area so that a safe, secure building can be found.

x. Proposed office space cannot be co-located (in a multi-tenant building) with any tenant that can be categorized or advertises as a night-life venue, nor be located within 1,000 feet of a night-life venue.

c. CRITERIA FOR AWARD OF COMMERCIAL OR LEASED SPACES.

i. A copy of the floor plan for the specific floors being offered by a lessor must be provided to

Tenant for review before acceptance of the specific floor and building.

ii. Floors in a specific location that have multiple building core items (multiple elevator banks, multiple stairwells, and multiple mechanical rooms) will not be accepted when they are not centrally located in the center of a space. These items cannot be within Tenant space.

d. PARKING

i. Secured parking spaces are required for government vehicles. The government requires a parking garage with a secure fenced/divided area or on-grade lot within a secure fenced area. Access to the parking area is required at all times (24-hours per day). It is desirable that only TENANT personnel have access to the parking area. If parking cannot be provided on-site (i.e. basement garage, attached building garage, or site lot), parking can be located within a two-block radius of the office if a waiver is granted as noted below.

Access to the parking lots must be controlled. Parking lots and all access from the building to the parking lots must be well lit at all times to ensure safety (i.e. a minimum of 10 foot candle level of illumination). Parking spaces cannot be in a shared lot with buildings that house agencies or tenants listed on page 1.

*Note any waiver from this requirement will require a review of the specific location by the ATF Physical Security Branch. A waiver may be considered if the market area does not have any locations that can provide a secure parking garage, secure fenced parking, or adjacent on-site parking.

The minimum requirements for secure parking enclosure are as follows:

ii. 9 gauge chain link fence, a minimum of 8’ high.

iii. Minimum of three strands of barbed wire running horizontally and continuously along the top of the fence.

iv. Privacy slats pre-inserted.

v. Sliding gate and pedestrian entrance.

vi. Minimum of three continuous horizontal rails placed at the top, bottom and mid-point of the fence.

vii. All vertical fence posts shall be embedded in concrete.

Prior to signing the lease, the landlord should notify GSA if there are any concerns regarding the parking enclosure. All cost associated with the fence enclosure will be charged against the Tenant improvement allowance or paid by TENANT through the initial construction build-out.

2. BUILDING EXTERNAL ENVIRONMENT

The quantity and quality of police and fire protection and the general character of the overall external environment shall also be considered in determining the location of the TENANT office buildings. All buildings considered by TENANT are required to have well-lit exterior sidewalks, parking structures/lots/spaces, and alleys to ensure safety.

3. SPACE PLANS:

TENANT’s Space Management Branch (SMB) will develop the space plans unless otherwise noted.

4. SECURITY

All security related components will be furnished and installed by TENANT’s security contractor such as the motion detectors, cameras, etc. unless otherwise noted on the space plans or program requirements prepared by TENANT.

a. Security Camera Location – Cameras will be potentially placed in all perimeter entrances and adjacent corridors on floor as well as stairwells. A drawing will be provided to the Lessor prior to installation of cameras.

5. EMPLOYEE PARKING / PUBLIC TRANSPORTATION

Regularly scheduled public transportation and/or sufficient parking to cover commuting needs of employees must be located within reasonable and safe walking distance of the office.

6. SIGNAGE

No external signage identifying TENANT presence in a facility is permitted. Internal signage is permitted on the floor where TENANT is located.

7. SECURITY CLEARANCE

The Government requires the lessor to submit complete personal history statements for each employee of the lessor as well as employees of the lessor's contractors or subcontractors who will provide continuing building operating services for the property in which the leased space is located. TENANT reserves the right to require completed fingerprint charts. TENANT also requires this information for employees of the lessor, his contractors, or subcontractors who are hired to perform alterations or emergency repairs for the property.

All contract personnel (i.e. cleaning personnel, maintenance personnel, contractor, sub-contractor, etc.)

who are hired to perform building operating services, alterations or emergency repairs for the property are required to complete a Personnel Security Request (PSR) and pass TENANT security background checks before working in TENANT space. (See Exhibit #1)

TENANT through the GSA contracting officer or Contracting Officer’s Representative will advise the lessor in writing if an employee is found to be unsuitable or unfit for his assigned duties. Effective immediately, such an employee cannot work or be assigned to work in TENANT leased space. The lessor will be required to provide the same data within 10 working days for the addition of new employee(s) to the work force.

In the event the lessor's contractor/subcontractor is subsequently replaced, and the new contractor/ subcontractor hires employees who were already cleared, then it is not necessary for them to be cleared again. The contracting officer may require the lessor to submit Form FD-258 and GSA Form 176 for every employee covered by this clause, on a recurring 3-year schedule.

Law Enforcement Sensitive material shall not be posted on any websites by contractors/subcontractors to include specifications, drawings or photos.

8. KEY CONTROL

It is the Tenant’s intent to control keys for Tenant space and the Tenant reserves the right to change the entrance locks to all Tenant space within the building. If the lessor and/or building manager require access into TENANT space after work hours, the lessor and/or building manager must inform Tenant and receive permission to gain access into Tenant space. Tenant personnel must be present at all times to escort non-Tenant personnel.

9. DAYTIME CLEANING, RENOVATION, AND MAINTENANCE

Daytime cleaning shall be included as part of the rental consideration. Daily cleaning, renovation in existing space, and scheduled maintenance must be conducted during business daytime hours between 8 AM to 4 PM. All after-hour work must be scheduled through TENANT. TENANT personnel must be present at all times to escort non-TENANT personnel.

10. MAINTENANCE FOR ABOVE STANDARD HVAC ITEMS

Maintenance for all above standard HVAC equipment shall be included as part of the rental consideration. If the HVAC equipment maintenance is not included in the initial rental proposal, adjustments to the rent may be executed after the above standard HVAC is/are installed and in operation.

11. ANTENNA SPACE:

Outside roof space may be required for the installation of a 22’ antenna (to be supplied by TENANT).

The base station should be located as close to the antenna as possible in a roof top equipment room where available. The antenna mount requires that it be made from 2” rigid conduit that is a minimum of 4’ in length and extends a minimum of 4’ above the highest point of the roof. The roof must be equipped for routing coaxial cable between the antenna and the base station. If conduit is required, the lessor shall provide conduit with a minimum of 2” inside diameter rigid conduit from the antenna mount to the base station location with no more than a total of 280 degrees of bends. Pull strings and weather head on the end that penetrates the building will also be required. An internal 8-wire, Category 5 cable is required from the TENANT office space to the base station location. The lessor shall provide a duplex AC outlet for the base station that is a 20 amp/110 Volt dedicated GFI circuit.

The dedicated AC outlet and an earth ground (central building ground) connection shall be located within 3’ of the base station location. The exact location of the antenna and base station must be coordinated with the TENANT, Radio Communications Branch located in Gaithersburg, MD and can be contacted at (202) 648-9150.

12. SYSTEMS FURNITURE WHIPS

In all TENANT projects that incorporate systems furniture, the general contractor shall be responsible for hardwiring one end of the whip to the electrical circuits. Note that TENANT’s systems furniture contractor will install the opposite end of the whip or make the final connection to the systems furniture.

13. TENANT’s ACCEPTANCE OF SPACE

GSA will formally accept the space for the Government in lease space projects. At a minimum, TENANT will require that the build-out of the perimeter of the space (i.e. walls, wire mesh, door installation, and hardware) must be complete prior to completion of the interior build-out of the space.

This will help to ensure that perimeter security is in place at the scheduled move date and that an office may be able to complete its move even if some internal construction still needs to be completed.

14. LAN ROOM COMPLETION

The LAN room vinyl composition floor tile, drywall partition, door/frame/hardware (with lockable hardware), plywood blocking, ceiling lights, power outlets (for the security, telephone and data), and air-conditioning unit must be complete once the secure perimeter walls/doors have been erected. This will help ensure that TENANT offices have the communications and computer infrastructure and tools needed for their work even if some additional construction still needs to be complete. The LAN room completion date shall be coordinated at the pre-construction meeting.

END OF OFFICE REQUIREMENTS

B. DESIGN AND CONSTRUCTION REQUIREMENTS

1. DESIGN INTENT DRAWINGS

Tenant will provide the design intent drawings along with the program of requirements to the Lessor, building manager, GSA representative, and/or architect.

The TENANT Space Requirements section describes TENANT’s architectural and security standards for each type of office space. The architect shall use these requirements as a guideline in producing the Construction Documents.

In the event of a conflict between this document and the Design Intent drawings, the Design Intent Drawings will prevail.

2. SQUARE FOOTAGE

Square footage requirements are noted on the programming requirements and are not included in this document. Changes to the square footage requirements or variations from the TENANT Space Requirement standards must be approved by TENANT’s Space Management Branch.

3. STANDARD FINISH, DOOR, CEILING, LIGHTING REQUIREMENTS

TENANT’s standard finishes are as follows (unless noted otherwise):

i) 26 - 28 ounce (face weight) carpet;

ii) continuous vinyl cove base;

iii) eggshell paint on walls;

iv) semi-gloss on doors and door frames;

v) solid core doors with minimum dimensions of 3’-0” x 7’-0” x 1-3/4” doors and hollow steel door frames;

vi) 2’x4’ or 2’x2’ acoustical ceiling tiles and ceiling grid; and

vii) 2’ x 4’ or 2’ x 2’ – Manufacturer: Focal Point, Model: Luna or equal , 3-Lamp, T8 recessed indirect w/ perforated center standard basket. See Exhibit 15 for further specifications.

4. DEMISING WALLS

(Note in construction, Perimeter and Demising walls may describe two different types of walls. In construction, Perimeter walls describe the exterior walls of the building and demising walls describe the exterior walls of the Tenant’s space. Personnel in the security industry may describe the exterior walls of the secured space as the Perimeter walls. For the Purpose of this document, TENANT will use the term Perimeter Walls and Demising Walls interchangeably but its meaning will remain the same - i.e. exterior walls of TENANT space.)

Demising walls of TENANT facilities must be acoustically separate from neighboring buildings or from other Tenants sharing space in the same building. All perimeter walls separating TENANT space from building common areas or other Tenants, whether government or non-government, must be separated with wall partitions that extend from the structural floor to the structural ceiling. Demising walls must have a minimum sound transmission class (STC) of 45 and contain 3 inch sound blanket insulation between five-eighths inch gypsum partitions. This includes public corridor walls. (See Exhibit #3a.) Acoustical sealant shall be applied on both sides of the metal stud runner at both slabs.

On floors/ceilings with composite metal decks, the partition, sound insulation, and acoustical sealant shall extend between the flutes of the metal decks. All service boxes shall be sealed. All electrical conduit cables shall be plugged with an acoustical lining and constructed to impede sound t r a n s m i s s i o n .

In addition, a minimum of ¾” #9 Standard or 9-gauge expanded carbon steel (expanded metal) shall be mounted to the outer side of the wall studs and run from slab-to-slab. The long way of the diamond opening in the expanded metal shall be no greater than 2 inches and should be consistent throughout the space. (See Exhibit #2). In cases where concrete block is used as a demising wall, expanded metal may be eliminated.

In some cases, TENANT will move to existing office space. The existing demising walls shall be reinforced with slab to slab expanded metal. It is preferable to weld the expanded metal on the outside face of the walls, but if this is not possible, securing the expanded metal on the inside face of the walls is acceptable. (Note, welding may not be possible if the existing stud gauge is too thin or if the space on the opposite side of TENANT’s space is occupied.) TENANT will allow the installation of the expanded metal on the TENANT side of the demising wall with non-removable screws and metal retaining clips in these instances.

The prospective lessor shall be responsible for identification of the current condition of the demising partition and shall report these conditions to TENANT. TENANT will then determine the modifications that are required to insure that the demising partition results in at least a 3A partition type.

The prospective lessor / GSA must notify TENANT within 72 hours of receipt of the Design Intent Drawings to report these conditions.

5. PERIMETER DOORS

Office perimeter entrance doors (from the public corridor) are required to be solid wood construction with a minimum thickness of 1-3/4 inches with an automatic door closure. These doors shall have long-throw, high-security, single-key deadbolt locks installed for secured hours. Doors will be tight fitting with one-half of an inch by one-eighth of an inch solid neoprene stop on three sides and threshold. There will be no transparent panels installed on these doors. All corridor doors (public and suite) will have a door sweep to stop sound transmission.

Warehouse perimeter doors shall be insulated metal doors.

TENANT will maintain control of all perimeter door keys. Emergency access to TENANT space will be by TENANT authorization only. All perimeter doors will have lock covers to prevent forced entry.

All perimeter doors (i.e. entrance, second entrance/exit, or stairwell doors) that swing out into public space from TENANT’s space should have hinge pins that are spot-welded, braided, provided with non-removable pin hinges, or security stud hinge to prevent removal of perimeter entrance doors. (A security stud hinge has a metal stud on the face of one hinge leaf and a hole in the face of the other leaf.

As the door closes, the stud enters the hole and penetrates the full thickness of the leaf, which create s a "bolting" or "locking" effect.)

The main entrance to all Division offices from the building lobby shall have solid core wood double doors.

6. VENTS AND DUCTS ALONG DEMISING WALLS

Vents and Ducts and all other openings along the demising walls with a total dimension of more than 90 square inches will be protected by the installation of hardened steel round bars, 3/8” in diameter, meeting a 600 Brinell hardness rating, spaced on 6” centers. The steel bars shall be welded to a ¼” steel angle iron frame. The steel frame and its supports shall be supported to the building structure by welding or the use of tamper free anchoring devices. Where feasible, the hardened steel bars and steel angle iron frame shall be anchored to the masonry wall by drilling holes into the wall and using tamper proof anchors epoxy glued into the wall or weld steel angle iron frame to the expanded metal within the demising partition.

7. EMERGENCY/FIRE EXITS

Emergency/Fire Exits shall be equipped with panic bars and a quick-release long-throw dead bolt lock for after hours. These doors must be alarmed. Hinges shall meet the requirements outlined above for perimeter entrance doors.

8. SECURITY AND DOOR HARDWARE

TENANT’s Physical Security Programs Branch (PSPB) will provide supplemental requirements and specifications during the Construction Document phase (See Exhibit 4 for a sample of the Security System and Lock Symbols). If the specifications noted within this document conflict with the specifications provided by PSPB during the Construction Document phase, the supplemental requirements and specifications from PSPB will supersede the specifications noted in this document.

The General Contractor shall furnish and install all door hardware and electric strikes noted on the construction documents unless otherwise noted. Electric strikes shall conform to TENANT’s minimum standards identified on Exhibit #5 - Security Electronic Portal Controls (Electric Strikes).

Prior to purchasing and installation of the electric strikes, the contractor must submit manufacture’s detailed information of the electric strikes (i.e. cut sheet, brochure description, etc….) for TENANT’s approval.

All electric strikes shall have the following options: 24 volt power and fail secure options.

Changes to any security related issues must be approved by TENANT’s Physical Security Programs Branch.

9. TELEPHONE AND SECURITY SYSTEM EQUIPMENT

All telephone and security alarm system equipment are to be located WITHIN the TENANT controlled office area. Telephone and computer closets will be secured by commercial grade locking devices. TENANT will maintain key control.

10. CONDUITS FOR ELECTRIC AND TELEPHONE LINES

Dedicated conduits are to be run from point of entry into the building (“Demark point”) to TENANT’s space. Provide a 3” flexible metal conduit from the main telephone room into the building to TENANT’s main LAN room. If pull boxes are necessary due to existing conditions, they must be outfitted with tamper resistant screws.

If the data or telephone cable leaves TENANT space and passes through the public hallway, the TENANT/Project Manager should request for two 3” flexible metal conduits that pass through the public hallway.

C. ABOVE STANDARD REQUIREMENTS

1) SECURE FOYER

a) FROM BUILDING LOBBY TO SECURE FOYER

1) Purpose Main entrance secure foyer will be designed to affect positive control and identification of visitors. The secure foyer has two doors – the Suite Entrance Door and the Reception Door.

Visitors enter the reception room from the public space through the Suite Entrance Door, but visitors may only pass through the Reception Door after receiving clearance from a TENANT staff.

2) Special Items

(A) Hardware for the suite entrance door is as follows: a standard levered lockset, latch plate cover, a door closer, single cylinder long-throw deadbolt, and bottom and side mounted door seals. If the doors swing out into the corridor, provide latch protectors and non-removable hinge pins.

(B) Demising partition shall be slab to slab with 45 STC and with a minimum of a 9 gauge welded expanded metal. See Exhibit #2.

b) FROM RECEPTION ROOM INTO TENANT SPACE

1) Special Items

(A) Walls around the secure foyer:

(a) Bullet Resistant treatment is required on all the walls within the secure foyer. See wall Type 3B. Specifications of the bulletproof wall must meet minimum UL ratings that are capable of withstanding bullets fired from a 44 magnum or a 9-mm submachine gun at close range (UL Level 3 rating). See Exhibit #6 – Security Armor.

(b) Demising partitions shall be slab to slab with 45 STC and with 9 gauge welded expanded metal. This is the partition between the secure foyer and public hallway See wall Type 3A.

(B) Bullet Resistant Doors

Bullet Resistant doors are required along walls with bullet resistant treatment only. The bullet proof doors shall meet minimum UL ratings that are capable of withstanding bullets fired from a 44 magnum or a 9 mm submachine gun at close range (UL Level 3 rating). See Exhibit #7.

(C) Bullet Resistant Windows

The landlord and/or architect should coordinate the window size with TENANT’s design intent drawings. See Exhibit #8. TENANT will notify the Lessor and/or architect if the existing bullet resistant windows at their present location will be relocated to the new space.

2) LAN ROOM

a) Purpose This room shall house the security, telephone, Wide Area Network (WAN) and Local Area Network (LAN) equipment.

b) Special Items

1) Provide five 20 amp quad outlets for the following:

(A) 2 quad outlets for the LAN/WAN equipment

(B) 2 quad outlets for the Telephone equipment

(C) 1 quad for the security system. In addition, the contractor shall provide two 3’-0” power strip/plug mold on each side of the security system outlet.

2) Provide six painted, fire-retardant plywood sheets, 4’ x 8’ x ¾” – two for the security equipment, two for the telephone system, and two for the LAN equipment. (See Exhibit #16 the layout for the typical LAN room.)

3) Install two #6 dedicated ground for the telephone equipment.

4) A mechanical engineer shall design an air-conditioning system that maintains the temperature in the LAN room between 70-74 degrees Fahrenheit 24-hours a day.

3) DIVISION CONFERENCE ROOM

Used for staff meetings, briefings, Critical Incident Management Response Team (CIMRT), press conference, and joint seminars with other law enforcement agencies.

1) Provide blackout drapery if the conference/training room is located along the window wall.

2) Provide at least two general-purpose outlets on every wall and one voice/data outlet on each wall.

3) Provide support for white board.

4) Provide a separate HVAC unit for this room

4) CONFERENCE ROOM (For Field Offices)

Used for meetings, briefings, and/or interviews with the staff or the public.

1) Provide blackout drapery if the conference room is located along the window wall.

2) Provide at least one general-purpose outlet on every wall and one voice/data outlet on each wall.

3) Provide support for white board.

5) SUPPLY ROOM

Required for general office supplies.

Provide a dedicated outlet for each photocopier.

6) MAIL AND COPY ROOM (For Division Office Only)

Required for photocopiers, facsimile machines, shredders, and the storage of paper, toner cartridges, recycling bins, and general office supplies.

b) SPECIAL ITEMS

Provide a dedicated outlet for each photocopier and each shredder.

7) POLYGRAPH EXAMINATION ROOM

The Polygraph Examination Room is required only at the Field Division offices when a Polygraph Examiner is on staff.

1) Install an “IN USE” outside of the Polygraph Room Door to indicate that a polygraph test is in progress with a separate light switch. Locate the center of the “IN USE” light fixture 66” above the finished floor adjacent to the door. Also, place a sign for the “In Use” light switch below the cover plate inside the Polygraph Examination room. The sign should read: “Turn on when room is in use.”

8) POLYGRAPH OFFICE

a) Special Items

1) Provide a 24” high x 30” width one-way mirror window between the polygraph examiner’s office and polygraph examination room. Locate the bottom of the window 48” above the finished floor. In addition, provide a 1” wide mini blind on the “office side” of the window.

2) Provide two down-light fixtures on a dimmer switch. Locate the down-light fixtures on the opposite side of the room from the one-way mirror.

9) BREAKROOM

a) Special Items

General contractor is to provide the sink and cabinetry (See Exhibit #9). Also provide space for a standard refrigerator and coordinate with the field office.

10) TRAINING ROOM (For Division Office Only , unless otherwise specified)

This space is provided as a conference room and training facility for entire Division Office. The size of this room will be based on 80% of the entire Field Division population.

1) Provide a separate HVAC unit for this room. Engineer shall be consulted.

2) Provide a 3” raised access floor.

3) Provide carpet tile.

4) Provide and install manual room darkening shades.

5) Standard acoustical ceiling with standard lighting and downlights around perimeter of room.

Lights should be on dimmer switches

6) Provide and install vinyl wallcovering.

7) Provide and install chair rail in specified locations.

8) Provide plywood blocking for TV mounts. Locations and quantities to be determined by

TENANT designer.

9) Provide and install movable partition.

10) Provide minimum 500sf storage room for tables and chairs when space allows. Tenant designer to provide drawing.

11) Provide AV closet or closet area for AV equipment.

12) Provide electrical and voice/data outlets in raised floor and other locations. Locations to be determined by TENANT designer.

11) SECURE FILE ROOM

Used to store investigative material and other sensitive files.

1) None

12) INTERVIEW ROOM

Interview rooms are small conference rooms used to interview defendants. Note, not all Field or Satellite offices require separate Conference and Interview Rooms. Architect is to confirm program of requirements if the Conference Room is also used as an Interview Room.

1) Handcuff Bar or D-Ring (See below.)

13) DEFENDANT PROCESSING ROOM

This room is used to photograph, fingerprint, and process defendants. For offices with five or less special agent personnel assigned, a combination Interview/Defendant Processing Room shall be provided.

1) Base cabinet and Sink Provide base cabinet with 20 gauge stainless steel, 8” deep sink with garbage disposal, and running hot and cold water. Base cabinet/sink height and faucet shall conform to the Uniform Federal Accessibility Standards (UFAS). See Exhibit #9.

2) Handcuff Bar or D-Ring

Each TENANT office will choose one of the following restraints in the processing room.

(A) Handcuff Bar Provide a handcuff bar described on Exhibit #10. Handcuff bar must be welded to stainless steel flanges and anchored to the wall to withstand a force of 900 pounds.

Flanges and cover plates must be 18 gauge, type 304 stainless steel tubing with a satin finish. All handcuff bars must have a 1-1/2” wall clearance. Position the handcuff bar horizontally 36” above the finished floor.

(B) D-Ring

Provide two wall mounted D-Rings mounted on two stainless steel kick plates. The rings should be mounted 5" AFF and 25" AFF. The D-Rings are screwed to wood blockings behind the drywall partition. Grind all bolts down or use tamper proof screws to prevent anyone from removing the D-rings from the wall. See Exhibit # 10.

14) SECURED / EVIDENCE STORAGE (For Field and Satellite Offices)

Each field office or group requires a secured storage room to safely store ammunition, weapons, investigative equipment, and evidence.

(A) Long Gun Rack. See Exhibit #11. See space plan for the number of long gun racks.

(B) 4’x8’ pegboard for a hand gun rack. See Exhibit #12. See space plan for the number of pegboard and location.

(C) Use partition Type 3E.

(D) Vents and Ducts and all other openings inside the security storage area with a total dimension of more than 90 square inches will be protected by the installation of hardened steel round bars, 3/8” in diameter, meeting a 600 Brinell hardness rating, spaced on 6” centers. The steel bars shall be welded to a ¼” steel angle iron frame. The steel frame and its supports shall be supported to the building structure by welding or the use of tamper free anchoring devices. Where feasible, the hardened steel bars and steel angle iron frame shall be anchored to the masonry wall by drilling holes into the wall and using tamper proof anchors epoxy glued into the wall or weld the steel angle iron frame to the expanded metal within the secured partition.

(E) Separate Investigative Area -- Divide the storage room with a slab to slab expanded metal partition into two areas. Provide a sliding gate with a hasp and latch secured with a high security changeable combination padlock (See Exhibits #13a, 13b, and 13c).

15) IRS PLOTTER

Large architectural printers or plotters are placed in the IRS Plotter rooms. Space is necessary for one 72” x 36” work table.

NA

16) COMMUNICATION ROOM (For Field Division Office Only)

This room houses the Treasury Enforcement Communications System (TECS), national, state and/or local law enforcement communication systems. This room is also used to store sensitive messages and documents.

1) Provide 24-hour self-contained HVAC unit in this room that maintains the temperature in the Communications room between 70-74 degrees Fahrenheit 24-hours a day.

17) Secret Internet Protocol Router Network (SIPRNET) Rooms SIPRNET Room (For Field Division Office Only?)

Secret Internet Protocol Router Network (SIPRNET) Rooms.

a) Purpose SIPRNET room doors will be solid wood with a minimum thickness of 1 ¾ inches or a hollow steel door with the steel a minimum thickness of 9-guage and locked with a card reader and electric strike for non-secure hours. A long-throw, single-key deadbolt lock will be installed for use during secured hours. Frames and hinges must be of sufficient strength to support the weight of the door. The walls shall extend from true floor to true ceiling. If this cannot be achieved, then the addition of 9-gauge mesh must extend from the ceiling to the slab above.

b)

NOTE: The Purposes of the following rooms are self-explanatory. There are no special requirements in each of the offices. However, the design intent drawings will convey the finishes and wall types and door hardware for the space.

18) DIVISION DIRECTOR’S OFFICE

19) CHIEF COUNSEL’S OFFICE

20) ASSISTANT SPECIAL AGENT IN CHARGE (ASAC)

21) DIRECTOR OF INDUSTRY OPERATIONS (DIO)

22) DIVISION COUNSEL’S OFFICE

23) STAFF ATTORNEY

24) SUPERVISOR’S OFFICE

25) FIREARM INSTRUCTOR COORDINATOR STORAGE ROOM

26) INDUSTRY OPERATIONS (IO) SECURE STORAGE ROOM

27) COMPUTER SPECIALIST STORAGE ROOM

End of Above Standard Requirements Section

D. EXHIBITS

1) Personnel Security Request (PSR)

2) 9 Gauge Wire Mesh

3) Partition Types

a) Slab to slab, 45 STC, with reinforced expanded metal

b) Slab to slab with Bullet Resistant Armor

c) Slab to slab partition

d) Partial height wall with cap

e) Slab to slab with reinforced expanded metal

f) Slab to ceiling

g) Slab to slab, 45STC with sound insulation

h) Slab to ceiling

j) Partition w/ viewing glass

4) Security System And Lock Symbols

5) Electronic Portal Controls (Electric Strikes, Magnetic Locks, and other electronic controls)

6) Security Armor

7) Bullet Resistant Door

8) Bullet Resistant Window

9) Sink Detail

a) Sink Cabinet Elevation

b) Sink Cabinet Section

10) Handcuff Bar and D-Rings

11) Long Gun Rack

12) Pegboard Detail

13) Secured Storage Partition Details

a) Secured Storage Gate – Elevation

b) Secured Storage Gate – Section

c) Secured Storage Gate – Sliding Door Hardware

14) Typical Telephone / LAN Room

15) Security Hardware

16) Lighting Specification

EXHIBIT #01 (A-C)

TITLE: Personnel Inquiry Request

TITLE: 9 GAUGE EXPANDED METAL (Amico or Approved Equal)

AMICO®

SECURITY MESH

PRODUCT NAME

PRODUCT DESCRIPTION

Security Expanded Metal sheets are steel expanded metal panels used as a penetration resistance shield behind plaster or drywall finishes. These sheets are to be attached to metal studs and track or wood supports designed for use in walls, floors, ceilings and roofs.

Basic Use: Prisons, government offices, strip malls, record storage rooms, computer rooms, courthouses, museums, mini warehouses, apartments, condominiums, pharmacies, art galleries, mail room, airport security, banks, hospitals, police stations and general office security.

Composition and Material: Security Expanded Metal is made by simultaneously cutting and stretching a solid sheet of steel, making Security Expanded Metal one continuous sheet that can't ravel at the strands.

Readily available in carbon steel, uncoated, galvanized, as well as stainless steel.

TECHNICAL DATA

AMICO Security Mesh is manufactured in conformance with the following industry standard specifications:

Carbon Steel - ASTM A569/A569M-85 Carbon Steel Security Mesh - ASTM F1267-89, Type I and II, Class 1, 2 and 3, Grade A Stainless Steel 304 - ASTM-A-240-90

Product Terminology:

SWD - Short Way of Diamond LWD - Long Way of Diamond Bond - The point where adjacent stands intersect.

Strand Thickness - Overall finished thickness

INSTALLATION

Methods of Cutting: 10" hand held circular saw with abrasive blade, cutting torch, nibbler heavy duty high speed. Eye and ear protection should be worn during the cutting operation.

Methods of Attachment:

• Welding to steel studs and track. Weld Security expanded metal with 1/8" x 1/2" lg. min. fillet welded to steel studs - 20 ga. or heavier, edge welds must be within 2" of edge.

• Pan head type self-drilling screws with at least a #8 shank, long enough to penetrate through steel supports at least 3/8 inch.

• One way fasteners screws long enough to penetrate through steel supports at least 3/8 inch.

• End joints of Security Expanded metal must be butted and occur over studs.

• Side Joints must be butted and wire tied at midpoint between supports.

• For maximum strength and ease of installation, LWD of sheet should be placed horizontally.

• Underwriters Laboratories Fire Rated Assemblies will not be jeopardized by using ASM in the fire rated assembly. (U/L Subject File #1857)

MANUFACTURER

Alabama Metal Industries Corp.

3245 Fayette Avenue Birmingham, Alabama 35208 Phone: (205) 787-2611

(800) 366-2642

FAX: (205) 786-6527

AMICO – West Alabama Metal Industries Corp.

11093 Beech Avenue Fontana, California 92335 Phone: (714) 350-9280

(800) 624-4600 I.S.

(800) 962-0100

TITLE: 9 GAUGE EXPANDED METAL (Amico or Approved Equal)

EXHIBIT #02

TITLE: 3A-SLAB TO SLAB, 45 STC, WITH REINFORCED EXPANDED METAL

EXHIBIT #3A

TITLE: 3B-SLAB TO SLAB WITH BULLET RESISTANT ARMOR

EXHIBIT #3B

EXHIBIT #3C

TITLE: 3C-SLAB TO SLAB

EXHIBIT #3D

TITLE: 3D- PARTIAL HEIGHT WALL W/CAP

TITLE: 3E-SLAB TO SLAB WITH REINFORCED EXPANDED METAL

EXHIBIT #3E

TITLE: 3F-SLAB TO CEILING

EXHIBIT #3F

TITLE: 3G-SLAB TO SLAB, 45STC, WITH SOUND INSULATION

EXHIBIT #3G

TITLE: 3H-SLAB TO CEILING - INSULATED

EXHIBIT #3H

TITLE: 3J-PARTITION W/ VIEWING GLASS

EXHIBIT #3J

EXHIBIT #4

TITLE: SECURITY LEGEND

2 *

SECURITY SYSTEM AND LOCK SYMBOLS

C

* E

KEYPAD

BALANCED MAGNETIC CONTACT

DIRECT LINE OF SIGHT

DUAL TECH DETECTOR IA/ MICROWAVE

360 DEGREE

DUAL TECH DETECTOR IA/ MICROWAVE

SECURITY SYSTEM CONTROL/ POWER W/ VISTA

100 CONTROL PANEL

ELECTRIC STRIKE W/ PWR SUPPLY (24V) **

BOLLARDS/ PLANTERS

RED LIGHT - ABOVE INTERVIEW ROOM

DOOR W/ SWITCH

DIGITAL VIDEO RECORDER (30/60/90 DAY)

L (1 TB MIN - W/VIDEO DOWNLOAD CAPABILITY)

CCTV CAMERA W/HOUSING (STD/ DIGITAL) COLOR

DOME/CEILING MOUNT (MINI-DOME) 3" TO 4" DOMES

CCTV CAMERA PAN-TILT-ZOOM (STD/ DIGITAL) COLOR

DOME/CEILING ROOF MOUNT (MINI-DOME) 6" DOME

AUDIO VISUAL SURVEILLANCE CAMERA

G GLASS BREAK DETECTOR

M AIPHONE AUDIO/ VIDEO CALL STATION (COLOR) - KB-DAR

W/ 24V POWER SUPPLY

AIPHONE AUDIO/ VIDEO MAIN ROOM SUB STATION W/ DOOR

H RELEASE - KB-3MRD W/ DESK STAND - COLOR

PROXIMITY CARD READER - HID

SB STROBE WITH SOUNDER - (RED/ BLUE/ AMBER) 110 DB

N INTERCOM - VOICE ONLY (IF-DN/DA)

WINSTEAD EQUIPMENT RACK W/ WORKSTATION CCTV

- LCD FLATSCREEN MONITOR (COLOR) (19"/ 21")

A CARD ACCESS COMPUTER SYSTEM (CASI RUSCO)

* SLIDE BOLT (LEFT/RIGHT) TOP AND BOTTOM

* 110 VOLT OUTLET (ABOVE CEILING/ BELOW TILE)

Q

* T

* Y

* W

1 * K

CCTV SPLITTER/ MULTIPLEXOR/ SIGNAL AMPLIFIER

DOUBLE CYLINDER DEADBOLT

SINGLE CYLINDER DEADBOLT

WEDGE READER (LAN ROOM)

AUTOMATIC DOOR CLOSER

MAG MAGNETIC LOCK (900 LBS) W/ POWER SUPPLY

LOCK * DOOR COVER PLATE

V VCR (104/360) LAN ROOM * SR STORE ROOM LOCK

MODEM * OF OFFICE LOCKSET

PROXINITY COMPUTER CONTROL SYSTEM PRINTER * IN

INSTITUTIONAL LOCK

D DURESS BUTTON EN ENTRANCE LOCKSET (MAIN ENTRANCE)

PA PASSAGE SET

BUREAU OF ALCOHOL, TOBACCO AND FIREARMS

PROTECTIVE PROGRAMS BRANCH

* GENERAL CONTRACTOR INSTALLATION

PROVIDE 1" CONDUIT ON PERIMETER DORRS AND SECURE

EVIDENCE DOORS WHERE THERE IS AN ELECTRIC STRIKE.

EXHIBIT #05

TITLE: ELECTRONIC PORTAL CONTROLS

ELECTRONIC PORTAL CONTROLS

The following are the minimum requirements for Electronic Portal Controls including electric strikes, magnetic locks and other electronic controls. ATF’s Physical Security Branch will determine the need for and authorize electronic portal controls.

A) DEVICE SPECIFICATIONS

All electronic locks installed in ATF space shall have:

1) Leakage of under 60 Gauss at 6 inches and less than 1 Gauss at 2 inches energized or de-energized.

2) A 600 pound forcing strength (in the opening direction). Forcing strength shall be measured in actual pressure in pounds that it takes to pull the lock apart.

3) Capability to operate with 12 or 24 volt D.C. power and to integrate with a remote opening system / device.

4) Standard built in electronics to eliminate residual magnetism and also to provide transient suppression.

5) Capability to meet guidelines from ANSI and BHMA and be U.L. listed for burglar resistance.

6) A status sensing mechanism that indicates the door is closed and locked.

7) Applicability for installation with hollow metal, solid core wood door, glass aluminum and fire doors.

8) Capability of fail-secure operation.

9) Protection against forced attack such as picking, drilling and prying.

10) Resistance to rust and water.

B) INSTALLATION REQUIREMENTS

1) All leads for the electronic locks shall be inaccessible from the exterior (unprotected side) of the door. When leads must be installed exposed, all wiring shall be encased in armored cable.

2) All devices shall be installed per the manufacturer’s specifications.

3) All doors designated as Emergency Exits shall use a U.L. listed fail-secure device.

4) All electronic locking devices shall be powered from a constant, continuous power source.

EXHIBIT #06

TITLE: SECURITY ARMOR

REFERENCE

The publications listed below form a part of this specification. UNDERWRITERS LABORATORY UL 752 10th Edition, Standard for Bullet Resisting Equipment dated March 10, 2000. ASTM E119-98 Standard Test for One-Hour Fire-Rating of Building Construction and Materials.

SUBMITTALS

Submit for approval prior to fabrication samples, brochures, specifications, UL LISTING Verification and UL752 Current Test Results as provided by Underwriters Laboratories, and printed data in sufficient detail to indicate compliance with the contract documents. ASTM E119-98 One-Hour Fire Rating of Building Construction and Materials. Manufacturer’s Instructions for installation of Bullet Resistant Fiberglass Panels.

DESIGN

Through the design, manufacturing technique and material application the Bullet Resistant Fiberglass shall be of the “non ricochet type”. This design is intended to permit the encapture and retention of an attacking projectile lessening the potential of a random injury or lateral penetration.

DELIVERY, STORAGE AND HANDLING

Deliver the materials to the project with the manufacturer’s UL LISTED Labels intact and legible. Handle the material with care to prevent damage. Store the materials inside under cover, stack flat and off the floor.

WARRANTY

All materials and workmanship shall be warranted against defects for a period of two (2) years from the date of receipt at the project site.

PRODUCTS

2.1 BULLET RESISTANT FIBERGLASS MATERIAL

The panels shall be made of multiple layers of woven roving ballistic grade fiberglass cloth impregnated with a thermoset polyester resin and compressed into flat rigid sheets. The production technique and materials used shall provide the controlled internal delamination to permit the encapture of a penetrating projectile. Bullet Resistant Fiberglass panels: 7/16” maximum thickness, and 4.7 pounds per square foot maximum weight.

1. ArmorCore Level 3 by Waco Composites I. Ltd., Waco, Texas. Toll Free 866-688-3088, Fax#(254)776-1424, Web Site: www.armorcore.com

2. GE Polymershapes Insulgard, 7663 Industrial Boulevard, Allentown, PA 18106, 800-893-9657, Fax# (610) 366-7701, Web Site: www.insulgard.com

2.2 SECURITY LEVEL

The Bullet Resistant Fiberglass will be rated and tested for UL752 Level 3.

EXECUTION

3.1 SUPPORTING MEMBERS

Prior to installing the bullet resistive material the contractor shall verify that all supports have been installed as required by the contract documents and the architectural drawings.

3.2 JOINTS

All joints shall be reinforced by a back-up layer of bullet resistive material. The bullet resistance of the joint, as reinforced, shall be at least equal to that of the panel. Minimum width of reinforcing layer at joint shall be 4-inches (2” on each panel or a 2” minimum overlap).

3.3 APPLICATION

Armor shall be installed in accordance with the manufacturer’s printed recommendations. Armor panels shall be adhered using an industrial adhesive, mastic, screws or bolts. Method of application shall maintain the bullet resistive rating at junctures with the concrete floor slab, the concrete roof slab, the bullet resistive door frames, the bullet resistive window frames, and all required penetrations.

Note this is a sample specification from the ArmorCore Level 3 by Waco Composites I. Ltd., Waco, Texas. Other manufactured bullet resistant armor meeting the minimum specifications noted above may be accepted by tenant. However, contractors must submit documentation to tenant for approval prior to purchasing and installing the bullet resistant armor.

http://www.armorcore.com/ http://www.insulgard.com/

EXHIBIT #07

TITLE: BULLET RESISTANT DOOR

INSULGARD CORPORATION

HM544 BULLET RESISTING DOOR SYSTEM

Bullet Resisting Product Data

FEATURES

• U.L. LISTED LEVEL 3

• 11 GAUGE FACE SHEETS

• CONTINOUS HINGE PREPARATION

• CLOSER REINFORCED

• COMPLETE HARDWARE OUTFITTING

• 3' 0" X 7' 0" FULL OPAQUE DOORS

• DOOR AND FRAME SHIPPED AS COMPLETE UNIT

• USE OF GE PLASTICS LEXGARD® IN VISION LITE

PRODUCT DESCRIPTION

• The Insulgard HM544 Bullet Resisting Door System is designed to defeat ballistic assaults from a .44

Cal. Magnum handgun per testing under UL standard 752 at Underwriters Laboratories. The door is a hollow metal swing type for interior and exterior use, and standard door usage.

BASIC USE

• Use of this door system is to provide protection in those applications where a ballistic attack threat exists. Such applications are often in convenience stores, law enforcement facilities, hospital pharmacies and many other "at risk" facilities. It is recommended that this door be used in conjunction with protected wall areas.

LIMITATIONS

• This door has been designed to meet the Level 3 ballistic resistance standard as set forth by UL Standard 752. It is recommended that each end user should determine his ballistic threat and determine the correct product to meet and resist that threat.

CONSTRUCTION

• Doors are to be full flush construction of 11 gauge ballistic steel face-plates arc welded to 14 gauge interior lock and hinge rails. Each door will have 14 gauge vertical steel stiffeners. Top and bottom of door to receive 14 gauge closure channels.

• Door framing will be constructed of 11 gauge ballistic steel and be offered in types for drywall and masonry openings.

• Door hardware (standard) will be: Continuous hinges, LCN closer

• Optional Hardware - Hardware materials shall be of a type listed above, unless otherwise requested. Contact your nearest Insulgard Corporation representative for additional optional hardware information.

• Finish - All doors and frames furnished prime painted, ready for final finish in field.

SIZES AND OPTIONS

• Door Thickness: 1-3/4"

• Frame thickness: 2" x 6-3/4"

• Standard door sizes: 36"x 84"

• (other sizes & styles available - 4 weeks)

• Door rough opening size: 40 1/2" x 86 1/4"

• Door shipping weight: 600 lbs. SPECIFICATION

• Door Construction - Doors are constructed of steel plates, and steel tubes 1 1/2" thick.

• Door Frame Construction –

Door frame assembly is constructed of formed steel plates. Framing dimensions are 2" wide x 6 3/4" deep. Door frames are completely fabricated at factory and shipped with doors attached. All door to be pre-tested for all locking functions, clearances, and ease of operation, to make field installation easier. All joint connections are welded to provide a rigid assembly when installed. Vertical jambs, door stops and transoms contain bullet resistant material equal to the value of the door unit. All seams of the door and frame are protected in the same manner. The door stop is built into the frame. Glenn Johnson Silencers are used at the lock jamb. Frames are pre-drilled to accept 1/4" anchors 18" O.C. Shims are provided to take up a space at each anchor. Wiring diagrams are shipped enclosed in the hardware packages.

• Hardware Assembly

Each door is equipped as follows: Door closer per door; Deadbolt lockset; continuous hinge. All other hardware must be specified.

Contact factory at 1-800-638-6718, Fax 301-927-4531. Insulgard is a registered trademark of Insulgard Corporation1994 Copyright Insulgard Corporation.

Note this is a sample specification from the Insulgard Corporation. Other manufactured bullet resistant door(s) meeting the minimum specifications noted above may be accepted by tenant. However, contractors must submit documentation to tenant for approval prior to purchasing and installing the bullet resistant door(s).

EXHIBIT #08

TITLE: BULLET RESISTANT WINDOW

INSULGARD® CORPORATION

SV TRANSACTION WINDOW

FEATURES

• Natural voice transmission system

• Stainless steel voice rails and deal tray

• Use of GE Plastics Lexgard laminates

• Delivered assembled & ready for installation

• U.L. Listed

BALLISTIC OPTIONS

• U.L. 752 Level 3

WINDOW SIZE

• See Design Intent Plans prepared by ATF

VOICE RAIL FINISH

• Stainless Steel (Standard)

COUNTER FINISH

• Stainless Steel

HANDLING INFORMATION

• Handling: Care should be exercised during shipping

• and handling to maintain transaction window appearance.

• Storage: Store…