B. Agency's Requirements (5).pdf
PDF 6 MB Posted
- Solicitation number
- 5AL0175
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Agency Name Program:
Project Location:
DOL Target UR Rate: 150 UR ( to be confirmed )
Quantity Per Type SF Projection
1 District Director Office 200 1 200 2 Assistance District Director Office 150 1 150 5 Community Outreach Resource Planning Specialists Workstation 100 1 100 7 Wage and Hour Adminstrative Specialist Workstation 100 1 100 8 Wage and Hour Technician Workstation 100 1 100 9 Wage and Hour Investigator Workstation 100 1 100
10 Wage and Hour Investigator Workstation 100 1 100 11 Wage and Hour Investigator Workstation 125 1 125 12 Wage and Hour Investigator Workstation 125 1 125
Quantity Per Type SF Projection
17 Reception Station Workstation 0 0 0 18 Entry Waiting Area Room 100 1 100 19 Break Room / Area Room/Area 0 0 0 20 Common Printer & Copy Stations Area 50 1 50 21 Main Server/LAN Room Room/Area 0 0 0 22 VTC ‐ Conference Room Room/Area 0 0 0 23 Training Room Room/Area 0 0 0 24 Storage Room 1 ( and LAN Room) Comb/room Room 100 1 100 25 Storage Room 2 ( Type of Storage to be specified ) Room/Area 0 0 0 26 Storage Room 3 ( Type of Storage to be specified ) Room/Area 0 0 0 27 0 0 28 0 0 29 0 0 30 0 0 31 0 0 32 0 0 33 0 0 34 0 0 35 0 0 36 0 0 37 0 0 38 0 0
Department of Labor - WHD Birmingham, Alabama
Staff/Populated Space Space Type
Approx. Square Footage (SF)
Total Personnel:
Subtotal:
Circulation Factor (38%):
Subtotal Usable Area:
Support Area/Unpopulated Space Space Type
Approx. Square Footage (SF)
Total Personnel:
Subtotal:
Circulation Factor (38%):
Subtotal Usable Area:
Agency Name Program:
Project Location:
DOL Target UR Rate: 150 UR ( to be confirmed )
Quantity Per Type SF Projection
1 Job Function 1 Office / Workstation 150 1 150 2 Job Function 2 Office / Workstation 150 1 150 5 Job Function 3 Office / Workstation 150 1 150 7 Job Function 4 0 8 Job Function 5 0 9 Job Function 6 0
10 Job Function 7 0 11 Job Function 8 0 12 Job Function 9 0 13 Job Function 13 0 14 Job Function 14 0 15 Job Function 15 0 16 Job Function 16 0
Quantity Per Type SF Projection
17 Reception Station Workstation 0 0 0 18 Entry Waiting Area Room/Area 0 0 0 19 Break Room / Area Room/Area 0 0 0 20 Common Printer & Copy Stations Room/Area 0 0 0 21 Main Server/LAN Room Room/Area 0 0 0 22 VTC ‐ Conference Room Room/Area 100 1 100 23 Training Room Room/Area 0 0 0 24 Storage Room 1 ( Type of Storage to be specified ) Room/Area 0 0 0 25 Storage Room 2 ( Type of Storage to be specified ) Room/Area 0 0 0 26 Storage Room 3 ( Type of Storage to be specified ) Room/Area 0 0 0 27 0 0 28 0 0 29 0 0 30 0 0 31 0 0 32 0 0 33 0 0 34 0 0 35 0 0 36 0 0 37 0 0 38 0 0
Department of Labor - OLMS Birmimgham, Alabama
Staff/Populated Space Space Type
Approx. Square Footage (SF)
Total Personnel:
Subtotal:
Circulation Factor (38%):
Subtotal Usable Area:
Support Area/Unpopulated Space Space Type
Approx. Square Footage (SF)
Total Personnel:
Subtotal:
Circulation Factor (38%):
DEPARTMENT OF LABOR SPACE REQUIREMENTS DOCUMENT
Office of Labor-Management Standards, Birmingham Resident Investigative Office
1. GENERAL INFORMATION
A. Mission
Page I
The Office of Labor-Management Standards (OlMS) in the U.S. Department of Labor is the Federal agency responsible for administering and enforcing most provisions of the Labor-Management Reporting and Disclosure Act of 1959, as amended (lMRDA). The lMRDA directly affects millions of people throughout the United States. The law was enacted by Congress primarily to ensure basic standards of democracy and fiscal responsibility in labor organizations representing employees in private industry. Unions representing U.S. Postal Service employees became subject to the lMRDA with the passage of the Postal Reorganization Act of 1970. The major provisions of the lMRDA are:
A "Bill of Rights" for union members;
Requirements for reporting and disclosure of financial information and administrative practices by labor unions;
Requirements for reporting and disclosure by employers, labor relations consultants, union officers and employees, and surety companies, when they engage in certain activities;
Rules for establishing and maintaining trusteeships;
Standards for conducting fair elections of union officers; and, Safeguards for protecting union funds and assets.
B. Geographic Area Served by This Office
1ZI Alabama 0 Kentucky 0 Puerto Rico
0 Florida 1ZI Mississippi 0 South Carolina
0 Georgia 0 North Carolina 1ZI Tennessee
0 [specify]
2. HOURS of OPERATION and ACCESSIBILITY
A. Public hours and accessibility o This space will not be open to the public.
1ZI This space will be open to the public Monday through Friday from 8:30 a.m. through 4:30 p.m. except on Federal holidays.
All leased space must comply with GSA's ABA Accessibility Standards (ABAAS).
B. Employee work hours
Employees normally work Monday through Friday, between 6:00 a.m. and 7:00 p.m.
In addition, employees need access to the office as follows:
o Shift workers work [day] through [day] from [hour) a.m. through [hour] p.m.
o Regular access on Saturdays from [hour) a.m. through [hour] p.m.
C:\Users\ Thomas_Darrell_B\AppData\LocaI\Microsoft\Windows\ Temporary Internet Fifes\Content. OutJook\KE2A VRYASpace_Requirements OLMS Birmingham. doc o Regular access on Sundays from [hour] a.m. through [hour] p.m.
o Access on holidays from [hour] a.m. through [hour] p.m.
~ 24-hour/day, 7 days/week access is required [occasionally]
C. ABAAS compliance for employees
The space must be accessible to disabled employees during all the hours of work listed above.
The agency's current staff has the following specific needs:
None.
3. BUILDING LOCATION
A. Driving to building
Space shall be located not more than the equivalent of two city blocks from a primary or secondary street.
Visitor parking, including parking for disabled visitors, shall be available either on-site or at a .public lot not more than one-quarter walkable mile away.
B. Public transportation o Preference will be given to space that is accessible via public transit.
o Space shall be located not more than one-quarter walkable mile from one of the following public transit stations:
4. BUILDING CRITERIA
A. Efficient use of space
Space we currently occupy is exactly how it needs to be set up.
B. Contiguous space
Space must be:
~ one contiguous block, without being split by a public corridor.
o as contiguous as possible (on a single floor, on contiguous floors, or on floors served by the same bank of elevators) with at least [number] of usable square feet in each contiguous block.
C. Restrooms
.The restrooms provided for men and women on each floor shall meet the schedule listed in the SFO for the following ratio of men and women:
~ 50% men, 50% women o [specify percentage] men, [specify percentage] women
D. Adjacencies
C:\Users\ Thomas_Darrell_BIAPpData\LocaI\Microsoft\Windows\ Temporary Internet Files\Content. OutlookV<E2A VRYASpace_Requirements OLMS Birmingham.doc
~ No adjacencies are required.
o This space must be adjacent to [specify).
E. Joint use areas
[for example, spots or recessed lights) o None.
~ The following areas will be jointly used by this agency and any DOL agency in same building:, [conference room, and LAN server area)
F. Freight elevator
Space must be serviced by a freight elevator. See Section 2.C. above for requirements for employee access.
G. Cleaning o Facilities shall be cleaned after public visiting hours, that is, after [hour) p.m.
~ Facilities shall be cleaned during normal business hours, that is, between 8:30 a.m. and 4:00 p.m.
H. Lighting
Lighting in the space must be available (can be turned on) whenever employees are present, as described in Section 2.B. above.
In addition to the exit and emergency lighting required in the Solicitation for Offers, emergency lighting must be installed in every windowless room. The lighting must provide at least 0.5 foot candles of illumination.
~ No special lighting, other than standard fluorescent lighting at 50 f.c, is required.
o Special lighting is required as follows:
Type of lighting:
Number of lights:
Location of lights: [room], as shown on the floor plan.
I. HVAC
HVAC system must operate Monday through Friday, from 6:30 a.m. through 7:00 p.m., except Federal holidays.
5. PARKING
o Garage parking is required.
o Garage parking is preferred but open-air parking is acceptable if it is secure, lighted, paved, striped, and graded for proper drainage.
Visitors' parking: see Section 3.A. above.
C:\Users\ Thomas-Darrell.B\AppData\LocaI\MicrosoftIWindows\ Temporary Internet Fifes\Content. OuflooklKE2A VRYASpBce_Requirements OLMS Birmingham. doc
6. GENERAL SECURITY REQUIREMENTS
A. Exterior doors
Lever-type slandard commercial-duty door handles shall be inslalled on all exlerior doors.
All exlerior doors will have dead-boll locks wilh alleasl a I-inch lhrow, have inaccessible hinge pins or non-rising fixed-hinge pins, be solid wood core or melal-shealhed, and be equipped wilh panic hardware and a key override. The locks musl also be lhumb-lurn lalches and nol double keyway lock cylinders.
B. Suite entry door
Malerial: [specify clear glass, frosled glass, solid wood core wilh a peephole, elc.]
Door handle: Lever-type slandard commercial-duty door handle.
Lock:
[gJ push-bullon mechanical or eleclronic cipher lock wilh key override and key lockoul, capable of being opened wilh one hand for ingress.
[gJ keyed lock, on lhe same masler key as lhe resl of lhe suile
D eleclronic card reader.
Clear opening: The suile enlry door shall provide a clear opening of alleasI44".
D A push-bullon ABAAS aulomalic door shall be inslalled on lhe suile enlrance.
D The suile enlry door will be locked al all limes. A doorbell shall be inslalled nexllo lhe enlry door, al an ABAAS heighl, 10signallhe receplionisllo open lhe door.
C, Door between reception waiting area and employee work space
[gJ A door separaling lhe public receplion wailing area and lhe employee workspace is nol required.
D A door shall be inslalled between lhe public receplion wailing area and lhe employee work space. This door will be equipped wilh:
D a push-bullon mechanical or eleclronic cipher lock wilh key override and key lockoul, capable of being opened wilh one hand for ingress.
D a keyed lock, on lhe same masler key as lhe resl of lhe suile
D an eleclronic card reader.
D. Separate employee entrance door
[gJ A separale employee enlrance is nol required (unless olherwise required by fire and life safety codes).
D The space shall have alleasl one separale employee enlrance providing ingress wilhoul going lhrough lhe receplion area. The employee enlrance door(s) will be equipped wilh:
D push-bullon mechanical or eleclronic cipher locks wilh key override and key lockoul, capable of being opened wilh one hand for ingress.
C:\Users\ Thomas_Darrell_B\AppData\Locaf\Microsoft\Windows\ Temporary Internet Fifes\Content. Outlook\KE2A VRYASpace_Requirements OLMS Birmingham.doc o keyed lock, on the same masler key as the rest of the suile o eleclronic card reader.
E. Interior doors
Malerial: Eilher clear glass or solid wood core with a peephole
Door handles: Lever-type standard commercial-duty door handle.
Self-closing hardware: ~ is required o is nol required.
All inlerior doors, other than glass doors (if any), will be 36" wide with an 18" wide sidelight of [specify clear or frosled] glass, unless olherwise slaled on lhe floorplan.
Locks:
~ Locks are not required on inlerior doors unless olherwise slated on lhe floorplan.
o All inlerior doors will have individual locks keyed to a common master lock for lhe whole suite, unless olherwise stated on lhe f1oorplan.
7. INTERIOR FINISHES AND REQUIREMENTS
A. Interior partitions
The inlerior walls (lenant's side of exlerior walls and bolh sides of interior office partitions) will be finished with:
~ painl (building standard) o vinyl wall covering (building standard)
B. Furniture secured to walls
All file cabinets, storage cabinets, and storage shelves exceeding five feel in height must be securely braced to the floor or wall with steel straps or equivalent devices to prevent falling or causing damage in the event of an earthquake.
C. Interior windows
Sidelights will be inslalled next to interior doors, as described in Section 6.E. above.
A clear glass interior window will be provided and installed in the following rooms:
Location of window Height Width o Conference room o Interview room o Private office(s) as noted on the f100rplan
Each window will be installed with lhe bottom edge approximately 42 inches above the finished floor. Each window will be covered with mini-blinds which are to be mounted on the inside of the window frame. Location of the windows will be shown on the f1oorplan.
FiJes\Content. Outlook\KE2A VRYASpace_Requirements OLMS Birmingham. doc
D. Floor covering
Glue-down Glue-down Broadloom Resilient carpet tiles broadloom carpet with flooring (no pad) carpet (no pad) carpet pad (vinyl)
Open areas X
Private offices X
Reception waiting area X
Conference room X
Storage room X
File room X
Copier area X
LAN server room X
[specify]
Baseboard material:
l:8J Vinyl o Painted or stained wood
8. SPECIAL FLOOR LOADS
A. High-density filing system l:8J None.
o A high-density filing system will be installed in the space. The floor load for this filing system is [number] pounds per sq. ft.
The system measures [number] feet wide by [number] feet long, for a total area of [number]
sq. ft. The adjacent corridor must be at least 44" wide by [number] feet long. The total .footprint of the system and adjacent corridor is [number] sq. ft.
o The movable units are manually operated; no electrical power is required.
o The system is motorized and has the following electrical requirements:
[describe]
B. Library l:8J None.
o A library will be installed in the space. The floor load for stacks is [number] pounds per sq. ft.
The stacks measure [number] feet wide by [number] feet long, for a total area of [number] sq.
ft. The adjacent corridor must be at least 44" wide by [number] feet long. The total footprint of the stacks and adjacent corridor is [number] sq. ft.
o The stacks are fixed; no electrical power is required.
o The stacks are movable and are manually operated; no electrical power is required.
Files\Content. Outlook\KE2AVRYASpace_Requirements OLMS Birmingham.doc
DEPARTMENT OF LABOR SPACE REQUIREMENTS DOCUMENT Page 7 o The stacks are motorized; the library system has the following electrical requirements:
[describe]
C. Other areas with heavy equipment or furnishings
18I None.
o [number] safes will be housed in the space. The safes weigh [number] pounds and have a combined footprint of [number] sq. ft.
o Other [specify type of furniture/equipment, number, size of footprint, and weight]
9. ELECTRICAL REqUIREMENTS
A. General
Electrical circuits within the space must be sufficient for the computer and office equipment listed on the Space Planning Worksheet.
B. Dedicated Circuits
Dedicated electrical circuits will be required for the following equipment.
Type of Equipment Location Number
Photocopier Copier area 1
Cisco 2600 and 2800 LAN server room 1
Small appliances circuit for Employee break area [specify] reirigerator, microwave, coffeepot, electric tea kettle
C. Conditioned Power
Conditioned power will be required for the following equipment:
Type of Equipment Location Number
[specify] LAN server room [specify]
[specify] [specify] [specify)
The wall or floor outlets for the conditioned power must be a distinctly different color than the other electrical outlets.
D. Uninterruptible Power Supply (UPS)
UPS will be required for the following equipment:
Type of Equipment Location Number
Cisco 2600 and 2800 LAN server room 1
[specify] [specify] [specify]
E. Additional Requirements
18I None
C:\Users\ ThDm8s~Darrell-BlAppData\Locaf\Microsoft\Windows\ Temporary Internet ~;I~~\""" •.•*•.••.•' """fI",nlr\I<t=?AV~VRSnRr.R Reauirements OLMS Birmingham.doc o [specify]
10. TELEPHONE SYSTEM REQUIREMENTS
A Government-owned telephone system will be installed in the space. Conduit with a minimum diameter of one inch must be in place to allow cable to be installed from the outside of the building to the space.
Additional information: [specify]
11. LAN SERVER ROOM
[gJ LAN server room information will be provided by Nation Office.
Separate LAN server rooms will be required if additional LAN equipment is needed or cannot be moved from current location.
[gJ A separate LAN server room is not required. The rack for the LAN server and router will be installed on the wall of the evidence or storage room.
o.A separate LAN server room is required, to house one or more equipment racks with the servers, routers, data switches, and other miscellaneous equipment needed to manage the network. This room has the following requirements:
Size: Approximately [number] square feet
Walls: Painted ceiling-high (slab-to-slab) walls
Floor covering: Vinyl tile
Entry door: Solid wood core or metal-sheathed door with hinges mounted inside the room. The room shall be secured with o a mechanical cipher lock o an electronic card reader
Fire extinguisher: An ABC type fire extinguisher is required.
HVAC: The room shall be provided with mechanical equipment to maintain a temperature between 68 degrees and 78 degrees Fahrenheit. The HVAC system must be capable of maintaining :t 2 degrees F. of the thermostat setting. This condition must be maintained 24 hours a day, 7 days a week. HVAC shall be thermostatically controlled within the room and be independent of the "house" system. The equipment located in the room will be operational 24 hours a day, 7 days a week. Window-unit type air conditioners are not acceptable.
Electrical: The room shall contain a minimum of [number] standard duplex electrical outlets circuited to a general purpose panelboard, and [number] duplex electrical outlets, type IG NEMA 5-20R or equivalent, circuited to an isolated ground panel board. [number] of these IG electrical outlets will be devoted to the LAN rack. Electrical power shall consist of one dedicated 115 volt, 60 Hz single-phase, 20 amp dedicated circuit with an IG wire for each of the [number] duplex IG electrical outlets.
C:\Users\ Thomas_Darrell_BlAppData\LocaI\Microsoft\Windows\ Temporary Internet Files\Content. OutJook\KE2AVRYASpace_Requirements OLMS Birmingham.doc
DEPARTMENT OF LABOR SPACE REQUIREMENTS DOCUMENT Page 9
Built-in storage:
Telephone: A telephone jack is required, to provide a convenience phone for employees working in the LAN server room. In addition, the following special telephone line(s) are required: [specify]
Other requirements: [specify]
12. COPIER AREA and/or WORK ROOM
The copier will require a dedicated electrical circuit and
[8J a telephone line for the fax function
[8J a LAN connection
[8J A separate work room is not required. The copier will be installed in open area.
Io A separate copier/work room will be provided. This room has the following requirements:
Size: Approximately [number] square feet
Flooring: Vinyl tile
Door: 0 No door is required o Interior door with
0 no lock
0 key lock
0 cipher lock
0 other [specify]
Work counter: A built-in laminate work counter will be installed at 30" above the finished floor. The work counter will be 24" deep and a minimum of [number] feet long.
o None o [specify type of cabinets or shelving, and dimensions)
Electrical: This room will have [number] of duplex outlets for other office equipment such as shredders, electric pencil sharpeners, electric hole punchers, etc.
Additional information: [specify]
13. CONFERENCEITRAINING ROOM
[8J A conference room is not required.
o A conference/training room will be provided. This room has the following requirements:
Size:
Maximum occupancy:
C:\Users\ Thomas_Darrell.B\AppData\Local\MicrosoftIWindows\ Temporary Internet FileslContent. Outfook\KE2A VRYASpace_Requirements OLMS Binningham. doc
DEPARTMENT OF LABOR SPACE REQUIREMENTS DOCUMENT Page 10
HVAC: This room [specify will or will not] require separate HVAC zone controls in order to maintain adequate ventilation and temperatures in the acceptable GSA range.
Walls: 0 Painted partitions o Glass o Partitions with an observation window o Partitions with a sidelight(s) next to the door(s) o A folding wall is required. Approximate length is [number) feet
Management of light levels:
o No special requirements o Light dimmers are required o Lights near the projection screen must be on a separate dimmer switch from the general lighting in the room, so that the area near the screen can be darkened independently of the overall lighting level in the room.
o Blackout curtains are required
Acoustical requirements o Standard: minimum of 40 STC for walls and 55 STC for ceiling o Special requirements: [specify]
Telephone: The room will be wired for o One regular station telephone o A conference telephone o A fax line o A LAN connection o A high-speed cable [specify]
NV equipment: The room will be equipped with the following audio-visual equipment:
o Whiteboard, [number) inches wide by [number) inches high o wall-mounted o recessed o electric connection required for whiteboard o Built-in retractable screen, [number] inches wide by [number] inches high o Built-in projector, mounted on [specify wall or ceiling] o Built-in sound amplification system
C:\Users\ Thomas-Darrell-B\AppData\Locaf\Microsoft\Windows\ Temporary Internet Files\Content. Outlook\KE2AVRYASpace_Requirements OLMS Birmingham.doc
D Wall-mounted rails for hanging posters
D Television
D Video-conferencing equipment
Additional information: [specify}
14. INTERVIEW ROOM
t8:J A private interview room is not required.
D A private interview room will be provided. This room has the following requirements:
Size: Approximately [number] square feet
Maximum occupancy: [number)
Walls: D Painted partitions
D Glass
D Partitions with an observation window
D Partitions with a sidelight(s) next to the door(s)
Acoustical requirements
D No special requirements
D [Specify sound conditioning requirements]
Additional information: [specify)
15. SECURE EVIDENCE ROOM
t8:J A secure evidence room is not required.
D A secure evidence room will be provided. This room has the following requirements:
Size:
Walls:
Page II
Floor covering:
Entry door: Solid wood core or metal-sheathed door with hinges mounted inside the room. The room shall be secured with
D a mechanical cipher lock
D an electronic card reader
Additional information: [specify)
16. BREAK AREA
C:\Users\ Thomas-Darrell-BlAppData\LocaI\Microsoft\Windows\ Temporary Internet Files\Content. Outlook\KE2A VRYASpace_Requirements OLMS Binningham. doc r8J A break area is not required if a shared break area is in the building.
o A break area will be provided.
Size: Approximately [number) square feet
Floor covering: Vinyl tile
Electrical: Adequate electrical circuits for a refrigerator, microwave, coffee maker, and electric kettle.
Plumbing: A built-in sink [specify is or is not] required.
Additional information: [specify]
17. LAB
r8J A lab is not required o A lab will be provided
Size: Approximately [number) square feet
Floor covering: Vinyl tile or [specify)
Electrical: Adequate electrical circuits for the following:
Orefrigerator, include size icemaker [specify is or is not) included.
Omicrowave, Ospecify other
Plumbing:
A built-in sink [specify is or is not] required.
Dishwasher [specify is or is not] required.
Additional information: [specify]
Cabinetry:
Countertops
Oiaminate
Ogranite
OWe
Upper and lower cabinetry
Olabinate
Owood, specify type _
Upper Cabinetry
C:\Users\ Thomas_Darrel/_B\AppData\LocaI\Microsoft\Windows\ Temporary Internet Files\Content. Outlook\KE2A VRYASpace_Requirements OLMS Birmingham. doc
DEPARTMENT OF LABOR SPACE REQUIREMENTS DOCUMENT Page 13
Dlockable
Dhardware [specify]
Dback splash
D specify other
17. ADDITIONAL REQUIREMENTS
Dopen
D closed
Dglass front
Additional storage space of approximately 100 square feet may be required to hold file cabinets and shelving units if we move to a new space.
C:\Users\ Thomas_Darrell_B\AppData\Locaf\Microsoft\Windows\ Temporary Internet Fifes\Content. Outfook\KE2A VRYASpace_Requirements OLMS Binningham.doc
Agency Name Program: OFCCP
Project Location: Birmingham
DOL Target UR Rate: 150 UR ( to be confirmed )
Quantity Per Type SF Projection
1 Job Function 1 Office / Workstation 150 1 150 2 Job Function 2 Office / Workstation 150 1 150 5 Job Function 3 Office / Workstation 150 1 150 7 Job Function 4 Office / Workstation 150 1 150 8 Job Function 5 Office / Workstation 150 1 150 9 Job Function 6 Office / Workstation 150 1 150
10 Job Function 7 Office / Workstation 150 0 0 11 Job Function 8 Office / Workstation 150 0 0 12 Job Function 9 13 Job Function 13 0 14 Job Function 14 0 15 Job Function 15 0 16 Job Function 16 0 uantity Per TySF Projection
17 Reception Station Workstation 0 1 0 18 Entry Waiting Area Room/Area 0 1 0 19 Break Room / Area Room/Area 0 1 0 20 Common Printer & Copy Stations Room/Area 0 1 0 21 Main Server/LAN Room Room/Area 0 1 0 22 VTC ‐ Conference Room Room/Area 100 1 100
Storage Room 1 (Case Files and
General) Room/Area 100 1 100 25 Storage Room 2 Room/Area 0 0 0
Storage Room 3 ( Type of Storage to be specified ) Room/Area 0 0 0 27 PIV Room Room/Area 250 1 250 28 0 0 29 0 0 30 0 0 31 0 0 32 0 0 33 0 0 34 0 0 35 0 0 36 0 0 37 0 0 38 0 0
Support Area/Unpopulated Space
Approx. Square Footage (SF)Staff/Populated Space
Subtotal Usable Area:
Total Personnel:
Space Type
Subtotal Usable Area:
Subtotal Usable Area:
Circulation Factor (38%):
Department of Labor - OFCCP Birmingham, Alabama
Total Personnel:
Space Type
Approx. Square Footage (SF)
Circulation Factor (38%):
Subtotal:
Subtotal:
Office of Federal Contract Compliance Programs Birmingham District Office
1. GENERAL INFORMATION
A. Mission
The purpose of the Office of Federal Contract Compliance Programs is to enforce, for the benefit of job seekers and wage earners, the contractual promise of affirmative action and equal employment opportunity required of those who do business with the Federal government.
Geographic Area Served by This Office
X Alabama 0 Kentucky 0 Puerto Rico
0 Florida 0 Mississippi 0 South Carolina
0 Georgia 0 North Carolina 0 Tennessee
X Northern Florida Panhandle and other geographic areas as directed by RO
2. HOURS of OPERATION and ACCESSIBILITY
A. Public hours and accessibility o This space will not be open to the public.
X This space will be open to the public Monday through Friday from 8:00 a.m. through 4:30 p.m. eJ:(cepton Federal holidays.
All leased space must comply with GSA's ABA Accessibility Standards (ABAAS).
B. Employee work hours
Employees normally work Monday through Friday, between 6:00 a.m. and 7:00 p.m.
In addition, employees need access to the office as follows:
o Shift workers work [day] through [day] from [hour] a.m. through [hour] p.m.
o Regular access on Saturdays from [hour] a.m. through [hour] p.m.
o Regular access on Sundays from [hour] a.m. through [hour] p.m.
o Access on holidays from [hour] a.m. through [hour] p.m.
X 24-hour/day, 7 days/week access is required [specify: frequently or occasionally]
C. ABAAS compliance for employees
The space must be accessible to disabled employees during all the hours of work listed above.
The agency's current staff has the following specific needs: None at this time.
3. BUILDING LOCATION
C:IUsersl Thomas-Darrell-BlAppDataILocaIlMicrosoftIWindowsl Temporary Internet FilesIContent.OutlookIKE2AVRYASpace_Requirements OFCCP - Birmingham.doc
DEPARTMENT OF LABOR SPACE REQUIREMENTS DOCUMENT Page 2
A. Driving to building
Space shall be located not more than the equivalent of two city blocks from a primary or secondary street.
Visitor parking, including parking for disabled visitors, shall be available either on-site or at a public lot not more than one-quarter walkable mile away.
B. Public transportation o Preference will be given to space that is accessible via public transit.
o Space shall be located not more than one-quarter walkable mile from one of the following public transit stations:
[Specify stations. Do not be so restrictive as to unfairly inhibit competition among potential building owners.]
4. BUILDING CRITERIA
A. Efficient use of space
. Space must be capable of being configured as shown in the attached Space Planning Worksheet.
B. Contiguous space
Space must be:
o one contiguous block, without being split by a public corridor.
X as contiguous as possible (on a single floor, on contiguous floors, or on floors served by the same bank of elevators) with at least [number] of usable square feet in each contiguous block.
C. Restrooms
The restrooms provided for men and women on each floor shall meet the schedule listed in the SFO for the following ratio of men and women:
~ 50% men, 50% women o [specify percentage] men, [specify percentage] women
D. Adjacencies
~ No adjacencies are required.
o This space must be adjacent to [specify].
E. Joint use areas o None.
X The following areas will be jointly used by this agency and Wage and Hour:
Conference Room
C:IUsersl Thomas_Darrell_BlAppDatalLocaI\MicrosoftIWindowsl Temporary Internet FileslContent. Out/ooklKE2A VRYASpace_Requirements OFCCP - Birmingham. doc
F. Freight elevator
Space must be serviced by a freight elevator. See Section 2.C. above for requirements for employee access.
G. Cleaning o Facilities shall be cleaned after public visiting hours, that is, after [hour] p.m.
~ Facilities shall be cleaned during normal business hours, that is, between 8:00 a.m. and 4:30 p.m.
H. Lighting
Lighting in the space must be available (can be turned on) whenever employees are present, as described in Section 2.B. above.
In addition to the exit and emergency lighting required in the Solicitation for Offers, emergency lighting must be installed in every windowless room. The lighting must provide at least 0.5 foot candles of illumination.
o No special lighting, other than standard fluorescent lighting at 50 f.c., is required.
~ Special lighting is required as follows:
Type of lighting:
Number of lights:
Emergency Lighting
Location of lights: Server/File room; rear CO office (neither have windows)
I. HVAC
HVAC system must operate Monday through Friday, from 6:30 a.m. through 7:00 p.m., except Federal holidays.
5. PARKING
[11r] reserved, off-street parking space(s) with in-and-out privileges is/are required for program purposes and/or for employees with disabilities. This parking must be lighted and shall be located on-site or within one-quarter walkable mile.
Employees must have access to the parking facility during all employee work hours, as described in Section 2.B. above.
o Garage parking is required.
X Garage parking is preferred but open-air parking is acceptable if it is secure, lighted, paved, striped, and graded for proper drainage.
Visitors' parking: see Section 3.A. above.
6. GENERAL SECURITY REQUIREMENTS
A. Exterior doors
C:IUsersl Thomas-Darrell-B\AppDataILocaIlMicrosoftIWindowsl Temporary Internet FileslContent. OutlooklKE2AVRYASpace_Requirements OFCCP - Birmingham.doc
DEPARTMENT OF LABOR SPACE REQUIREMENTS DOCUMENT Page 4
Lever-type standard commercial-duty door handles shall be installed on all exterior doors.
All exterior doors will have dead-bolt locks with at least a I-inch throw, have inaccessible hinge pins or non-rising fixed-hinge pins, be solid wood core or metal-sheathed, and be equipped with panic hardware and a key override. The locks must also be thumb-turn latches and not double keyway lock cylinders.
B. Suite entry door
Material: Solid wood core with a peephole
Door handle: Lever-type standard commercial-duty door handle.
Lock:
~ push-button mechanical or electronic cipher lock with key override and key lockout, capable of being opened with one hand for ingress.
o keyed lock, on the same master key as the rest of the suite o electronic card reader.
Clear opening: The suite entry door shall provide a clear opening of at least 44".
o A push-button ABAAS automatic door shall be installed on the suite entrance.
~ The suite entry door will be locked at all times. A doorbell shall be installed next to the entry door, at an ABAAS height, to signal the receptionist to open the door.
C. Door between reception waiting area and employee work space o A door separating the public reception waiting area and the employee workspace is not required.
o A door shall be installed between the public reception waiting area and the employee work space. This door will be equipped with:
o a push-button mechanical or electronic cipher lock with key override and key lockout, capable of being opened with one hand for ingress.
o a keyed lock, on the same master key as the rest of the suite o an electronic card reader.
D. Separate employee entrance door o A separate employee entrance is not required (unless otherwise required by fire and life safety codes).
~ The space shall have at least one separate employee entrance providing ingress without going through the reception area. The employee entrance door(s) will be equipped with:
~ push-button mechanical or electronic cipher locks with key override and key lockout, capable of being opened with one hand for ingress.
o keyed lock, on the same master key as the rest of the suite o electronic card reader.
C:IUsersl Thomas-DarreJl-BlAppDatalLocaflMicrosoftIWindowsl Temporary Internet FileslContent. OutlookIKE2A VRYASpace_Requirements OFCCP - Birmingham.doc
E. Interior doors
Material: solid wood core
Door handles: Lever-type standard commercial-duty door handle.
Self-closing hardware: 0 is required ! is not required.
All interior doors, other than glass doors (if any), will be 36" wide with an 18" wide sidelight of [specify clear or frosted] glass, unless otherwise stated on the floorplan.
Locks:
o Locks are not required on interior doors unless otherwise stated on the floorplan.
! push-button mechanical or electronic cipher lock with key override and key lockout, capable of being opened with one hand for ingress.
All interior doors will have individual locks keyed to a common master lock for the whole suite, unless otherwise stated on the floorplan.
7. INTERIOR FINISHES AND REQUIREMENTS
A. Interior partitions
The interior walls (tenant's side of exterior walls and both sides of interior office partitions) will be finished with:
! paint (building standard) o vinyl wall covering (building standard)
B. Furniture secured to walls
All file cabinets, storage cabinets, and storage shelves exceeding five feet in height must be securely braced to the floor or wall with steel straps or equivalent devices to prevent falling or causing damage in the event of an earthquake.
C. Interior windows
Sidelights will be installed next to interior doors, as described in Section 6.E. above.
A clear glass interior window will be provided and installed in the following rooms:
Location of window Height Width o Conference room o Interview room o Private office(s) as noted on the floorplan
Each window will be installed with the bottom edge approximately 42 inches above the finished floor. Each window will be covered with mini-blinds which are to be mounted on the inside of the window frame. Location of the windows will be shown on the floorplan.
D. Floor covering
C:IUsersl Thomas-Darrell-BlAppDatalLocaIlMicrosoftIWindowsl Temporary Internet FiJeslContent. OutJooklKE2AVRYASpace_Requirements OFCCP - Birmingham.doc
6r - Page I -
Glue-down I Glue-down -- carpet tiles Broadloom -
_Open areas - (no pad) broadloom Resilient ]carpet (no pad) carpet With -.£'rivate offices - X- carpet pad flooring
Reception waiting area X
_ (vinyl) }- X -
Conference room-
X _Storage room - File room
X
Copier area X
LAN server room X
[specify] X
DEPARTMENT
. OF lABOR SPACE REQUIREMENTS DOCUMENT
Baseboard material:
~ Vinyl o Painted or stained wood
8. SPECIAL FLOOR lOADS
A. High-density filing system
~ None.
o I!' high-density filing system will be installed in the space Th IS [number] pounds per sq. ft. . e floor load for this filing system
The system n:easures [~umber] feet wide by [number] feet long, for a total area of nu
sq. ft .. The adjacent corndor ~ust be at least 44" wide by [number] feet long. Th l t ~ber]
. footprint of the system and adjacent corridor is [number] sq. ft. e 0 a o The movable units are manually operated; no electrical power is required.
o The system is motorized and has the following electrical requirements:
[describe)
B. Library
~ None.
o A library will be installed in the space. The floor load for stacks is [number] pounds per sq. ft.
The stacks measure [number] feet wide by [number] feet long, for a total area of [number) sq.
ft. The adjacent corridor must be at least 44" wide by [number] feet long. The total footprint of the stacks and adjacent corridor is [number) sq. ft.
o The stacks are fixed; no electrical power is required.
o The stacks are movable and are manually operated; no electrical power is required.
o The stacks are motorized; the library system has the following electrical requirements:
C:IUsersl Thomas_Darrell-BlAppDatalLocaIlMicrosoftIWindowsl Temporary Internet FilesIContent.OutlookIKE2AVRYASpace_Requirements OFCCP - Birmingham.doc
[describe]
C. Other areas with heavy equipment or furnishings
X None.
o [number] safes will be housed in the space. The safes weigh [number] pounds and have a combined footprint of [number] sq. ft.
o Other [specify type of furniture/equipment, number, size of footprint, and weight]
9. ELECTRICAL REQUIREMENTS
A. General
Electrical circuits within the space must be sufficient for the computer and office equipment listed on the Space Planning Worksheet.
B. Dedicated Circuits
Dedicated electrical circuits will be required for the following equipment:
Type of Equipment Location Number
Photocopier LAN Server/File Room 1
Server/File Room LAN Server/File Room 2 PIV PIV Office 2-4 Small appliances circuit for LAN Server/File Room 2 refrigerator, microwave, coffeepot, electric tea kettle
C. Conditioned Power
Conditioned power will be required for the following equipment:
Type of Equipment Location Number
Server/Router LAN Server/File room 2-4 PIV PIV Office 2-4 The wall or floor outlets for the conditioned power must be a distinctly different color than the other electrical outlets.
D. Uninterruptible Power Supply (UPS)
UPS will be required for the following equipment:
Type of Equipment Location Number
Server/Router LAN Server/File Room 2 PIV PIV Office 2 Avaya Phone System LAN Server/File Room 2
E. Additional Requirements
C:IUsersl Thomas_Darrell_BlAppDatalLocaI\MicrosoftIWindowsl Temporary Internet
X None
D [specify]
10. TELEPHONE SYSTEM REQUIREMENTS
A Government-owned telephone system will be installed in the space. Conduit with a minimum diameter of one inch must be in place to allow cable to be installed from the outside of the building to the space.
Additional information: [specify]
11. LAN SERVER ROOM
D LAN server room information will be provided by Nation Office.
Separate LAN server rooms [specify will or will not be required].
D A separate LAN server room is not required. The rack for the LAN server and router will be installed on the wall of the [specify] room.
X A separate LAN server room is required, to house one or more equipment racks with the servers, routers, data switches, and other miscellaneous equipment needed to manage the network. This room has the following requirements:
Size: Approximately 125 square feet
Walls: Painted ceiling-high (slab-to-slab) walls
Floor covering: Vinyl tile
Entry door: Solid wood core or metal-sheathed door with hinges mounted inside the room. The room shall be secured with
X a mechanical cipher lock
D an electronic card reader
Fire extinguisher: An ABC type fire extinguisher is required. NOTE: CURRENTLY NO
FIRE EXTINGUISHER IN THE SERVER ROOM.
HVAC: The room shall be provided with mechanical equipment to maintain a temperature between 68 degrees and 78 degrees Fahrenheit. The HVAC system must be capable of maintaining :t 2 degrees F. of the thermostat setting. This condition must be maintained 24 hours a day, 7 days a week. HVAC shall be thermostatically controlled within the room and be independent of the "house" system. The equipment located in the room will be operational 24 hours a day, 7 days a week. Window-unit type air conditioners are not acceptable.
Electrical: The room shall contain a minimum of 2 standard duplex electrical outlets circuited to a general purpose panelboard, and a duplex electrical outlets, type IG NEMA 5-20R or equivalent, circuited to an isolated ground panelboard. a of these IG electrical outlets will be devoted to the LAN rack. Electrical power shall consist of one dedicated 115 volt, 60 Hz single-phase, 20 amp dedicated circuit with an IG wire for each of the [0] duplex IG electrical outlets.
C:\Users\ Thomas-Darrell-B\AppData\LocaI\Microsoft\Windowsl Temporary Intemet FileslContent. Outlook\KE2A VRYASpace_Requirements OFCCP - Birmingham.doc
DEPARTMENT OF LABOR SPACE REQUIREMENTS DOCUMENT Page 9
Telephone: A telephone jack is required, to provide a convenience phone for employees working in the LAN server room. In addition, the following special telephone line(s) are required: NA
Other requirements: NA
12. COPIER AREA and/or WORK ROOM
The copier will require a dedicated electrical circuit and
X a telephone line for the fax function
X a LAN connection o A separate work room is not required. The copier will be installed in [specify storage room, open area, etc.].
X A separate copier/work room will be provided. This room has the following requirements:
Size: Approximately 116 square feet
Flooring: Vinyl tile Carpet
Door: 0 No door is required
X Interior door with
0 no lock
0 key lock
X cipher lock
0 other [specify]
Work counter: A built-in laminate work counter will be installed at 30" above the finished floor. The work counter will be 24" deep and a minimum of [number] feet long.
Built-in storage: o None
X Open Shelving Units
Electrical: This room will have 4 of duplex outlets for other office equipment such as shredders, electric pencil sharpeners, electric hole punchers, etc.
Additional information: [specify]
13. CONFERENCE/TRAINING ROOM
o A conference room is not required.
X A conference/training room will be provided. This room has the following requirements:
Size: Approximately 400 square feet
Maximum occupancy: 20
C:IUsersl Thomas-DarreJl-BlAppDatalLocaIlMicrosoftIWindowsl Temporary Intemet FileslContent. Outlook\KE2AVRYASpace_Requirements OFCCP - Birmingham.doc
HVAC: This room will require separate HVAC zone controls in order to maintain adequate ventilation and temperatures in the acceptable GSA range.
Walls: 0 Painted partitions o Glass o Partitions with an observation window o Partitions with a sidelight(s) next to the door(s) o A folding wall is required. Approximate length is [number] feet.
Management of light levels:
o No special requirements x Light dimmers are required o Lights near the projection screen must be on a separate dimmer switch from the general lighting in the room, so that the area near the screen can be darkened independently of the overall lighting level in the room.
o Blackout curtains are required
Acoustical requirements x Standard: minimum of 40 STC for walls and 55 STC for ceiling o Special requirements: [specify]
Telephone: The room will be wired for
X One regular station telephone
X A conference telephone
0 A fax line
X A LAN connection
0 A high-speed cable [specify]
AN equipment: The room will be equipped with the following audio-visual equipment:
X Whiteboard, [number] inches wide by [number] inches high
X wall-mounted o recessed o electric connection required for white board
X Built-in retractable screen, [number] inches wide by [number] inches high o Built-in projector, mounted on [specify wall or ceiling] o Built-in sound amplification system
C:IUsersl Thomas-Darrell-BlAppDatalLocaflMicrosoftIWindowsl Temporary Internet o Wall-mounted rails for hanging posters o Television
X Video-conferencing equipment
Additional information: [specify]
14. INTERVIEW ROOM
o A private interview room is not required.
Page II
X A private interview room will be provided. (Conference Room currently being used, if necessary) This room has the following requirements:
Size: Approximately 400 square feet
Maximum occupancy: 20
Walls: 0 Painted partitions o Glass o Partitions with an observation window o Partitions with a sidelight(s) next to the door(s)
Acoustical requirements
X No special requirements o [Specify sound conditioning requirements]
Additional information: [specify]
15. SECURE EVIDENCE ROOM
X A secure evidence room is not required.
o A secure evidence room will be provided. This room has the following requirements:
Size: Approximately [number] square feet
Walls: Painted ceiling-high (slab-to-slab) walls, with [specify] gauge wire mesh to prevent entry through the walls.
Floor covering: Vinyl tile
Entry door: Solid wood core or metal-sheathed door with hinges mounted inside the room. The room shall be secured with o a mechanical cipher lock o an electronic card reader
Additional information: [specify]
C:IUsersl Thomas-Darrell-BlAppDataILocaflMicrosoftIWindowsl Temporary Internet FileslContent. Out/ookIKE2AVRYASpace_Requirements OFCCP - Birmingham.doc
16. BREAK AREA
X A break area is not required.
o A break area will be provided.
Size: Approximately [number] square feet
Floor covering: Vinyl tile
Electrical: Adequate electrical circuits for a refrigerator, microwave, coffee maker, and electric kettle.
Plumbing: A built-in sink [specify is or is not] required.
Additional information: [specify]
17. LAB
X A lab is not required o A lab will be provided
Size: Approximately [number] square feet
Floor covering: Vinyl tile or [specify]
Electrical: Adequate electrical circuits for the following:
orefrigerator, include size icemaker [specify is or is not] included.
Omicrowave, Ospecify other
Plumbing:
A built-in sink [specify is or is not] required.
Dishwasher [specify is or is not] required.
Additional information: [specify]
Cabinetry:
Countertops
Olaminate
Ogranite
Upper and lower cabinetry
Olabinate
Owood, specify type _
C:IUsersl Thomas-Darrell-BlAppDatalLocaflMicrosoftlWindowsl Temporary Internet FileslContent. Out/ookIKE2AVRYFlSpace_Requirements OFCCP - Birmingham.doc
DEPARTMENT OF LABOR SPACE REQUIREMENTS DOCUMENT Page 13
Otile
Olockable
Ohardware [specify]
Oback splash o specify other
17. ADDITIONAL REQUIREMENTS
[specify]
Upper Cabinetry
Oopen o closed
Oglass front
C:IUsersl Thomas-Darrell-BlAppDatalLocaIlMicrosoftIWindowsl Temporary Internet
| WHD Space Requirements.pdf |
| OLMS Space Requirements.pdf |
| OLMS Birmingham, AL Leasing Requirement Documents (1).pdf |
| 00000004 |
| 00000005 |
| 00000006 |
| 00000007 |
| 00000008 |
| 00000009 |
| 00000010 |
| 00000011 |
| 00000012 |
| 00000013 |
| 00000014 |
| 00000015 |
| 00000016 |
| OFCCP Space Requirements.pdf |
| OFCCP Birmingham, AL Leasing Requirement Documents (1).pdf |
| 00000005 |
| 00000007 |
| 00000009 |
| 00000011 |
| 00000013 |
| 00000015 |
| 00000017 |
| 00000019 |
| 00000021 |
| 00000023 |
| 00000025 |
| 00000027 |
| 00000029 |
File details come from the government source that posted it. Updated .