This document is a Solicitation (W912DS24Q0021) for a Request for Quotation (RFQ) issued by the U.S. Army Corps of Engineers, New York District. The solicitation requires a contractor to provide labor, materials, and equipment to accomplish various facility upgrades, including painting, carpet installation, door and window replacements, HVAC work, and other interior renovations for multiple Army, Navy, and Marine Corps recruiting stations located in New Jersey. The work must be completed within 120 days after contract award, which is scheduled for July 9, 2024. The solicitation is set aside for small businesses, with a NAICS code of 238390 and size standard of $19,000,000. The document provides detailed scopes of work and specifications for each location and service. Pricing is firm-fixed-price. No incumbent contractors are mentioned.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SEE ADDENDUM

(No Collect Calls)

W912DS24Q0021 06-Jun-2024

b. TELEPHONE NUMBER

917-790-8182

8. OFFER DUE DATE/LOCAL TIME

02:00 PM 09 Jul 2024

5. SOLICITATION NUMBER 6. SOLICITATION ISSUE DATE

AUTHORIZED FOR LOCAL REPRODUCTION

PREVIOUS EDITION IS NOT USABLE

STANDARD FORM 1449 (REV. 2/2012)

Prescribed by GSA – FAR (48 CFR) 53.212

(TYPE OR PRINT)

(SIGNATURE OF CONTRACTING OFFICER)

ADDENDA ARE

26. TOTAL AWARD AMOUNT (For Gov t. Use Only )

23.

CODE 10. THIS ACQUISITION IS

SUCH ADDRESS IN OFFER

17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT

BELOW IS CHECKED

TELEPHONE NO.

W912DS9. ISSUED BY

18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a. UNLESS BLOCK

7. FOR SOLICITATION

INFORMATION CALL:

a. NAME

JO A MCCUE

2. CONTRACT NO. 3. AWARD/EFFECTIVE DATE 4. ORDER NUMBER

(TYPE OR PRINT)

30b. NAME AND TITLE OF SIGNER 30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER

30a. SIGNATURE OF OFFEROR/CONTRACTOR 31a.UNITED STATES OF AMERICA

0 27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1. 52.212-4. FAR 52.212-3. 52.212-5 ARE ATTACHED.

25. ACCOUNTING AND APPROPRIATION DATA

1. REQUISITION NUMBER

20.

ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED.

OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, AND 30

SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS

ARE NOT ATTACHED

27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA ARE ARE NOT ATTACHED

(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE

SET FORTH HEREIN, IS ACCEPTED AS TO ITEMS:

. YOUR OFFER ON SOLICITATION

28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN

% FOR:SET ASIDE:UNRESTRICTED OR X

SMALL BUSINESS

17a.CONTRACTOR/ CODE FACILITY

OFFEROR CODE

US ARMY CORPS OF ENGINEERS, NEW YORK

26 FEDERAL PLAZA, RM 16-300

NEW YORK NY 10278-0090

18a. PAYMENT WILL BE MADE BY CODE

RATED ORDER UNDER

DPAS (15 CFR 700)

13a. THIS CONTRACT IS A

13b. RATING

CODE15. DELIVER TO CODE W912DS 16. ADMINISTERED BY

12. DISCOUNT TERMS11. DELIVERY FOR FOB DESTINA-

TION UNLESS BLOCK IS

MARKED

SEE SCHEDULE

14. METHOD OF SOLICITATION

RFQ IFB RFPX

REAL ESTATE OFFICE - NAN

ALICIA BIGGS

26 FEDERAL PLAZA ROOM 16-508

NEW YORK NY 10278

TEL: 917-790-8440 FAX:

212-264-3013FAX:

TEL: 917-790-8026 SERVICE-DISABLED

VETERAN-OWNED

SMALL BUSINESS

8(A)

HUBZONE SMALL

BUSINESSX

SIZE STANDARD:

$19,000,000

NAICS:

238390

X

OFFER DATED

29. AWARD OF CONTRACT: REF.

DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY

COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND

EMAIL:

TEL:

31c. DATE SIGNED

SEE SCHEDULE

SCHEDULE OF SUPPLIES/ SERVICESITEM NO. QUANTITY UNIT UNIT PRICE AMOUNT

24.22.21.19.

WOMEN-OWNED SMALL BUSINESS (WOSB)

ELIGIBLE UNDER THE WOMEN-OWNED

SMALL BUSINESS PROGRAM

EDWOSB

32g. E-MAIL OF AUTHORIZED GOVERNMENT REPRESENTATIVE

SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS

(CONTINUED)

ACCEPTED, AND CONFORMS TO THE CONTRACT, EXCEPT AS NOTED: ______________________________________________________

32a. QUANTITY IN COLUMN 21 HAS BEEN

RECEIVED INSPECTED

32b. SIGNATURE OF AUTHORIZED GOVERNMENT

REPRESENTATIVE

32c. DATE 32d. PRINTED NAME AND TITLE OF AUTHORIZED GOVERNMENT

REPRESENTATIVE

32e. MAILING ADDRESS OF AUTHORIZED GOVERNMENT REPRESENTATIVE 32f . TELEPHONE NUMBER OF AUTHORIZED GOVERNMENT REPRESENTATIVE

37. CHECK NUMBER

FINALPARTIALCOMPLETE

36. PAYMENT35. AMOUNT VERIFIED

CORRECT FOR

34. VOUCHER NUMBER

FINAL

33. SHIP NUMBER

PARTIAL

38. S/R ACCOUNT NUMBER 39. S/R VOUCHER NUMBER 40. PAID BY

41a. I CERTIFY THIS ACCOUNT IS CORRECT AND PROPER FOR PAYMENT 41b. SIGNATURE AND TITLE OF CERTIFYING OFFICER 41c. DATE

42a. RECEIVED BY (Print)

42b. RECEIVED AT (Location)

42c. DATE REC'D (YY/MM/DD) 42d. TOTAL CONTAINERS

STANDARD FORM 1449 (REV. 2/2012) BACK

Prescribed by GSA – FAR (48 CFR) 53.212

AUTHORIZED FOR LOCAL REPRODUCTION

PREVIOUS EDITION IS NOT USABLE

SEE SCHEDULE

20.

SCHEDULE OF SUPPLIES/ SERVICES

21.

QUANTITY UNIT

22. 23.

UNIT PRICE

24.

AMOUNT

19.

ITEM NO.

Section B - Supplies or Services and Prices

ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

1800 Clements Bridge Rd, Deptford, NJ

FFP

Army Recruiting Station at 1800 Clements Bridge Rd, Deptford, NJ

NET AMT

0001AA 1 Job

PAINT INTERIOR OFFICE AREA(S)

FFP

PAINT INTERIOR OFFICE AREA(S). See Scope of Work. Army Recruiting Station at 1800 Clements Bridge Rd, Deptford, NJ FOB: Destination

PSC CD: Z1AA

0001AB 1 Job

CARPET INSTALLATION

FFP

CARPET INSTALLATION. See Scope of Work. Army Recruiting Station at 1800 Clements Bridge Rd, Deptford, NJ

Navy at 1800 Clements Bridge Road

Navy at 1800 Clements Bridge Road, Deptford, NJ

0002AA 1 Job

INSTALL A NEW TV MOUNT BRACKET

FFP

INSTALL A NEW TV MOUNT BRACKET. See Scope of Work. Navy at 1800 Clements Bridge Road, Deptford, NJ

128 Route 70, Medford , NJ

Army Recruiting Station located at 128 Route 70, Medford , NJ

0003AA 1 Job

PAINT REQUIREMENT

FFP

ARMY OFFICE ONLY – PAINT REQUIREMENT. See Scope of Work. Army Recruiting Station located at 128 Route 70, Medford , NJ

0003AB 1 Job

CARPET INSTALLATION

FFP

CARPET INSTALLATION. See Scope of Work. Army Recruiting Station located at 128 Route 70, Medford , NJ

2274 S. Wrangleboro Rd, Mays Landing, NJ

FFP

Marines Recruiting Station located at 2274 S. Wrangleboro Road, Mays Landing, NJ

0004AA 1 Job

PAINT INTERIOR OFFICE AREA(S)

FFP

PAINT INTERIOR OFFICE AREA(S) MARINES OFFICE ONLY. See Scope of Work. Marines Recruiting Station located at 2274 S. Wrangleboro Road, Mays Landing, NJ

0004AB 1 Job

INSTALL CARPET TILES

FFP

INSTALL CARPET TILES; INTERIOR OFFICE AREA(S (MARINES OFFICE

ONLY. See Scope of Work. Marines Recruiting Station located at 2274 S.

Wrangleboro Road, Mays Landing, NJ

0004AC 1 Job

VINYL GRAPHIC

FFP

REPLACE WORDMARK “MARINES” & EAGLE, GLOBE & ANCHOR (EGA)

VINYL GRAPHIC (MARINES OFFICE ONLY. See Scope of Work. Marines Recruiting Station located at 2274 S. Wrangleboro Road, Mays Landing, NJ.

2274 S. Wrangleboro Rd, Mays Landing, NJ

Navy Recruiting Station located at 2274 S. Wrangleboro Road, Mays Landing, NJ

0005AA 1 Job

PAINT INTERIOR OFFICE AREA(S)

FFP

PAINT INTERIOR OFFICE AREA(S). See Scope of Work. Navy Recruiting Station located at 2274 S. Wrangleboro Road, Mays Landing, NJ.

0005AB 1 Job

INSTALL CARPET TILES

FFP

INSTALL CARPET TILES; INTERIOR OFFICE AREA(S). See Scope of Work.

Navy Recruiting Station located at 2274 S. Wrangleboro Road, Mays Landing, NJ.

0005AC 1 Job

INSTALL WALL GRAPHIC

FFP

INSTALL “TRAINING WALL GRAPHIC” AND “HONOR, COURAGE,

COMMITMENT WALL GRAPHIC”. See Scope of Work. Navy Recruiting Station located at 2274 S. Wrangleboro Road, Mays Landing, NJ.

818 Haddonfield Road, Cherry Hill, NJ

Army Recruiting Station located at 818 Haddonfield Road, Cherry Hill, NJ

0006AA 1 Job

PAINTING

FFP

PAINT ALL INTERIOR OFFICE AREAS, INCLDUING TESTING ROOM. See Scope of Work. Army Recruiting Station located at 818 Haddonfield Road, Cherry Hill, NJ

0006AB 1 Job

FLOORING

FFP

FLOORING REQUIREMENT (ARMY OFFICE ONLY) – REPLACE ALL

CARPET TILES; INTERIOR OFFICE AREA(S). See Scope of Work. Army Recruiting Station located at 818 Haddonfield Road, Cherry Hill, NJ

HWY 547, Lakehurst, NJ

Army Recruiting Battalion located at Joint Base MDL, HWY 547, Lakehurst, NJ

0007AA 1 Job

PAINTING

FFP

PAINT ALL INTERIOR OFFICE AREAS, HALLWAY INCLUDING THE

STORAGE ROOM & GENERAL WAREHOUSE (ARMY OFFICE ONLY). See Scope of Work. Army Recruiting Battalion located at Joint Base MDL, HWY 547, Lakehurst, NJ

0007AB 1 Job

FLOORING

FFP

FLOORING REQUIREMENT (ARMY OFFICE ONLY) – REPLACE ALL

CARPET TILES; INTERIOR OFFICE AREA(S). See Scope of Work. Army Recruiting Battalion located at Joint Base MDL, HWY 547, Lakehurst, NJ.

10 S. Haddon Avenue, Haddonfield, NJ

Marines Recruiting Station located at 10 S. Haddon Avenue, Haddonfield, NJ

0008AA 1 Job

INSTALL THERMOSTAT

FFP

INSTALL SMART DIGITAL THERMOSTAT ENERGY STAR RATED. See Scope of Work. Marines Recruiting Station located at 10 S. Haddon Avenue, Haddonfield, NJ.

0008AB 1 Job

REMOVE AND INSTALL DOOR

FFP

REMOVE AND INSTALL TEST ROOM FULL-LENGTH GLASS DOOR. See Scope of Work. Marines Recruiting Station located at 10 S. Haddon Avenue, Haddonfield, NJ.

0008AC 1 Job

REMOVE AND INSTALL DOOR

FFP

REMOVE AND INSTALL NEW SOLID DOOR (TO COMMON AREA(S)

FROM OFFICE ONLY). See Scope of Work. Marines Recruiting Station located at 10 S. Haddon Avenue, Haddonfield, NJ.

0008AD 1 Job

INSTALL NEW DUAL ROLLER SHADE

FFP

INSTALL NEW DUAL ROLLER SHADE. See Scope of Work. Marines Recruiting Station located at 10 S. Haddon Avenue, Haddonfield, NJ.

0008AE 1 Job

INSTALL NEW ENTRY BELL/CHIME

FFP

INSTALL NEW ENTRY BELL/CHIME-WIRE/MECHANICAL ABOVE

EXTERIOR MAIN ENTRANCE DOOR. See Scope of Work. Marines Recruiting Station located at 10 S. Haddon Avenue, Haddonfield, NJ.

Army 3333 Route 9 North, Freehold , NJ

Army Recruiting Station located at 3333 Route 9 North, Freehold , NJ

0009AA 1 Job

PAINTING

FFP

ARMY OFFICE ONLY – PAINT REQUIREMENT. See Scope of Work. Army Recruiting Station located at 3333 Route 9 North, Freehold , NJ.

Marines 3333 Route 9 North, Freehold, NJ

Marines Recruiting Station located at 3333 Route 9 North, Freehold, NJ

0010AA 1 Job Marines INSTALL CARPET TILES

FFP

INSTALL CARPET TILES; INTERIOR OFFICE AREA(S (MARINES OFFICE

ONLY). See Scope of Work. Marines Recruiting Station located at 3333 Route 9 North, Freehold, NJ.

0010AB 1 Job

REPLACE EXTERIOR MAIN ENTRANCE DOOR

FFP

REPLACE EXTERIOR MAIN ENTRANCE DOOR. See Scope of Work. Marines Recruiting Station located at 3333 Route 9 North, Freehold, NJ.

0010AC 1 Job

INSTALL GLASS FRAGMENTATION FILM

FFP

INSTALL GLASS FRAGMENTATION FILM ON NEW EXTERIOR MAIN

ENTRANCE DOOR AND INSTALL ENTRY BELL/CHIME ABOVE DOOR.

See Scope of Work. Marines Recruiting Station located at 3333 Route 9 North, Freehold, NJ.

0010AD 1 Job

INSTALL FIXED PANEL SHADE

FFP

INSTALL FIXED PANEL SHADE ON NEW EXTERIOR MAIN ENTRANCE

DOOR. See Scope of Work. Marines Recruiting Station located at 3333 Route 9 North, Freehold, NJ.

0010AE 1 Job

VIDEO INTERCOM ENTRY SYSTEM

FFP

REPAIR OR REPLACE ONE DESK STATIONS FOR VIDEO INTERCOM

ENTRY SYSTEM – SPECIAL APP#1. See Scope of Work. Marines Recruiting Station located at 3333 Route 9 North, Freehold, NJ.

2201 Route 38, Suite # 715, Cherry Hill, FFP

Army Medical Department Recruiting Station located at 2201 Route 38, Suite # 715, Cherry Hill, NJ

0011AA 1 Job

REPLACE INTERIOR OFFICE DOOR

FFP

REPLACE INTERIOR OFFICE DOOR WITH A NEW SOLID DOOR (TO

COMMONA AREA FROM OFFICE ONLY). See Scope of Work. Army Medical Department Recruiting Station located at 2201 Route 38, Suite # 715, Cherry Hill, NJ

TOTALS

Total CLIN’s 0001-0011 _____________________________

Section C - Descriptions and Specifications

SCOPE OF WORK

SCOPE OF WORK

GENERAL DESCRIPTION: The contractor shall provide all labor, material, equipment, and supervision to accomplish this FY 2024 Upgrade Request for the following locations and military services:

Army and Navy Recruiting Station located at 1800 Clements Bridge Rd – Suite C, Deptford, NJ (Gloucester County) Army Recruiting Station located at 128 Route 70, Medford, NJ (Burlington County).

Marines Corps and Navy Recruiting Station located at 2274 S Wrangleboro Road, Mays Landing, NJ (Atlantic County).

Army Recruiting Station located at 818 Haddonfield Avenue, Cherry Hill, NJ (Camden County).

Army Recruiting Battalion located at Joint Base MDL, HWY 547, Lakehurst, NJ (Ocean County).

Marines Recruiting Station located at 10 S. Haddon Avenue, Haddonfield, NJ (Camden County) Army and Marines Recruiting Station located at 3333 Route 9 North, Freehold, NJ (Monmouth County).

Army Medical Department (AMEDD) Recruiting Station located at 2201 Route 38, Suite # 710, Cherry Hill, NJ

(see below) Completion date after award date is 120 days, or sooner.

a. Selected Contractor must visit site before submitting their Quote Price.

b. Selected Contractor must complete this job no later than 120 Days at contract award and must start work prior to 30 September 2024.

c. Selected Contractor must complete this job during normal business hours (9am – 5pm) in the presence of an authorized military personnel. Under no circumstances will a contractor be given keys or access codes to the facility.

d. Selected Contractor must remove and dispose (from premises) all existing materials.

e. Selected Contractor will contact NARCISO A. PADILLA at 917-968-2891 and provide a work schedule before gaining access to the Installation.

f. Selected Contractor will secure work site before, during and after work job.

g. Selected Contractor must clean up after completing the job.

h. Selected Contractor must have legal and authorized personnel to perform this job. However, no security clearance is required.

i. Selected Contractor must relocate furniture and other items, within the center of the office space, storage room and/or testing room; however, storage and testing room should not be blocked from future access.

Contractor is responsible for moving and replacing all furniture, equipment including the wall artwork back to their original location.

j. Upon request from the Army Corps of Engineers, Owners/Property Manager, the selected contractor must provide insurance bond. (AMOUNT TO BE DETERMINDED BY

OWNER, IF REQUIRED OR REQUESTED) in the owner’s name.

k. Selected Contractor will contact NARCISO A. PADILLA (the POC) for full inspection after completion. Payments will not be released until the work is fully done and inspected.

l. Selected Contractor must be aware that payment may not be received until 60 days after work is completed and inspected.

Army Recruiting Station at 1800 Clements Bridge Rd, Deptford, NJ

ITEM 0001A: PAINT INTERIOR OFFICE AREA(S)

1. Painting: Army request to repair any visible damages in walls, nail holes and paint all interior office area(s).

Contractor will be responsible for removing and replacing all furniture as required.

ARMY PAINT SCHEDULE

Color Name: Color #: Product: Coats: Finish: Area:

PRIMER ProMar 200 White (see Note 1)

B28W02600 2 Latex: Acrylic Primer All Walls / All Painted Trim

United States Army Recruiting Off-White

SW 6148 Wool Skein B20W12651 2 Latex: Egg-Shell Walls

United States Army Recruitin g Khaki

SW 6150 Universal Khaki B31W2651 2 Latex: Semi-Gloss Trim

United States Army Recruitin g Green

SW 6166 Eclipse B20T2654 2 Latex: Egg-Shell Accent Wall

Note 1: ProMar 200 Primer to be tinted to match the applicable wall color for all walls, and all painted trim.

Note 2: Paint schemes and accent wall finishes to be applied as referenced on the approved floor plan / AE drawing / finish schedule.

Note 3: Accent wall to be: United States Army Recruiting Green.

Note 4: Restrooms: See Common Area Paint Schedule.

ITEM 0001B: CARPET INSTALLATION

1. Flooring:

a. Army request to remove all old carpet tiles in office area(s) and installing new carpet tiles in all office area(s).

b. Contractor will be responsible for removing and replacing all furniture as required.

c. Base Cove (for VCT & Carpet only): Johnsonite/Tarkett

(https://distributor.tarkett.com), Rubber; Color: #40, Black, 4” H.

d. Carpet Schedule (office, test room and related areas): Carpet tiles with base cove shall be installed throughout the entire space except storage rooms, restrooms, common area lobbies, corridors, and exit areas. All carpet must be installed smoothly and evenly in accordance with manufacturer’s instructions and with the approved low Volatile Organic Compounds (VOC’s) release adhesive. One (1) https://distributor.tarkett.com/ extra box of carpet tiles (for the Army at this location) shall be left in the security closet for future use.

ARMY CARPET SCHEDULE

Manufacturer / Style: U.S. Army Recruiting Standard: # 802E5 Color (Name, Number): Duty, BB90D Product: Carpet Tile Installation Method: Quarter Turn Installation Adhesive: "LokDots" Adhesive System

Navy at 1800 Clements Bridge Road – Suite C, Deptford, NJ ITEM

0002A: INSTALL A NEW TV MOUNT BRACKET

1. Communication:

a. Replace the existing TV mount bracket to mount the station’s new TV monitor.

b. Mounting pole: Mfr; Displays2Go, Model # SLC3770LBK - https://www.displays2go.com/P-29667/Swivel-Ceiling-TV Mount-Flat-

Inclined-Surfaces (telescoping pole sized for specific installation location, screen size and weight requiremen with 360° rotation and 25° tilting capable bracket).

c. Wiring to be routed thru / inside the mounting pole (power, HDMI cables, ethernet cables, etc.).

d. Pole to be mounted to understructure (through the drop ceiling tile) as identified on the approved floor plan / AE drawing along with:

• Bracing / framing to support minimal sway / movement.

• Installation to include a “ceiling plate” or “ceiling mast trim ring” cover (to cover the hole for the pipe in the drop ceiling) and secured to the ceiling tile (may require additional support above the ceiling tile to prevent future ceiling sagging / damage).

Color to match pole color.

• Within an appropriate distance along the wall (e.g. – approximately within 6” to 8”, allowing for appropriate movem at the location).

Army Recruiting Station located at 128 Route 70, Medford , NJ ITEM

0003A: ARMY OFFICE ONLY – PAINT REQUIREMENT

1. Painting: Paint all interior office area(s).

a. Army request to repair any visible damages in walls, nail holes and paint all interior office area(s). Contractor will be responsible for removing and replacing all furniture as required.

PRIMER ProMar 200 White (see Note 1)

B28W02600 2 Latex: Acrylic Primer All Walls / All Painted Trim

United States Army Recruiting Off-White SW 6148 Wool Skein B20W12651 2 Latex: Egg-Shell Walls

United States Army Recruiting Khaki SW 6150 Universal Khaki B31W2651 2 Latex: Semi-Gloss Trim

United States Army Recruiting Green SW 6166 Eclipse B20T2654 2 Latex: Egg-Shell Accent Wall

Note 1: ProMar 200 Primer to be tinted to match the applicable wall color for all walls, and all painted trim.

Note 2: Paint schemes and accent wall finishes to be applied as referenced on the approved floor plan / AE drawing / finish schedule.

Note 3: Accent wall to be: United States Army Recruiting Green.

Note 4: Restrooms: See Common Area Paint Schedule.

Note 5: If selected, contractor should request Sherwin Williams’ colors as “United States Army Recruiting...”

Formulas to these color names are available on Sherwin Williams’ National Accounts Database.

http://www.displays2go.com/P-29667/Swivel-Ceiling-TV

ITEM 0003B: CARPET INSTALLATION

a. Army request to remove all old carpet tiles in interior office area(s) and installing new carpet tiles in all interior office area(s).

b. Contractor will be responsible for removing and replacing all furniture as required.

c. Base Cove (for VCT & Carpet only): Johnsonite/Tarkett

(https://distributor.tarkett.com), Rubber; Color: #40, Black, 4” H.

d. Carpet Schedule (office, test room and related areas): Carpet tiles with base cove shall be installed throughout the entire space except storage rooms, restrooms, common area lobbies, corridors, and exit areas.

All carpet must be installed smoothly and evenly in accordance with manufacturer’s instructions and with the approved low Volatile Organic Compounds (VOC’s) release adhesive. One (1)extra box of carpet tiles (for the Army at this location) shall be left in the security closet for future use.

Color (Name, Number): Duty, BB90D Product: Carpet Tile Installation Method: Quarter Turn

Marines Recruiting Station located at 2274 S. Wrangleboro Road, Mays Landing, NJ

ITEM 0004A: PAINT INTERIOR OFFICE AREA(S) MARINES OFFICE ONLY

1. Painting: Marines request to repair any visible damages in walls, nail holes and paint all interior office area(s).

Contractor will be responsible for removing and replacing all furniture as required.

MARINES CORPS PAINT SCHEDULE

PRIMER ProMar 200 White (see Note 1)

B28W02600 2 Latex:

Acrylic Primer

All Walls / All Painted Trim

United States Marines Corps Recruiting Red

SW7586

Stolen Kiss B20R2658 2 Latex: Eg-Shel Walls

United States Marines Corps Recruiting Blue

SW9177

Salty Dog B20T2654 2 Latex: Eg-Shel Walls

United States Marines Corps Recruiting Khaki

SW6136

Harmonic Tan B20W12651 2 Latex: Eg-Shel Walls

United States Marines Corps Recruiting White

SW7526

Maison Blanche B20W12651 2 Latex: Eg-Shel Walls

United States Marines Corps Recruiting Gray

SW7645

Thunder Gray B31T2654 2 Latex:

Semi-Gloss Trim

Note 1: ProMar 200 Primer to be tinted to match the applicable wall color for all walls, and all painted trim.

Note 2: Paint schemes and accent wall finishes to be applied as referenced on the approved floor plan / AE drawing / finish schedule.

Note 3: United States Marines Corps Recruiting White to be applied in storage, test room and within MC controlled restrooms.

Note 4: For NCOIC offices, two walls to be Recruiting White, one wall to be Recruiting Khaki, and one wall to be Recruiting Blue as identified on the approved floor plan / AE drawing.

Note 5: Restroom: See Common Area Paint Schedule.

ITEM 0004B: INSTALL CARPET TILES; INTERIOR OFFICE AREA(S (MARINES OFFICE

ONLY

1. Flooring: Remove old carpet tiles and install new carpet tiles; interior office area(s).

a. Base Cove (for VCT & Carpet only): Johnsonite / Tarkett (https://distributor.tarkett.com), Rubber;

Color: #40, Black, 4” H.

b. Carpet Schedule (office, test room and related areas): Carpet tiles with base cove shall be installed throughout the entire office space except storage rooms, restrooms, common area lobbies, corridors, and exit areas.

All carpet must be installed smoothly and evenly in accordance with manufacturer’s instructions and with the approved low Volatile Organic Compounds (VOC’s) release adhesive. One (1) extra box of carpet tiles (for the Marines at this location) shall be left in the security closet for future use.

MARINE CORPS CARPET SCHEDULE

Manufacturer / Style: U. S. Marine Corps Recruiting Standard: # 710S4 Color (Name, Number): Lead, 49500 Product: Carpet Tile Installation Method: Monolithic

ITEM 0004C: REPLACE WORDMARK “MARINES” & EAGLE, GLOBE & ANCHOR (EGA)

VINYL GRAPHIC (MARINES OFFICE ONLY

1. Interior Signage - Marine Corps Interior Wall Graphics:

a. Replace Wordmark “Marines” Vinyl Graphic – current Marine’s wordmark is peeling off the wall.

b. Replace Eagle, Globe & Anchor (EGA) Vinyl Graphic – current EGA graphic is peeling off the wall.

c. Location of wall graphics will be as referenced on the floor plan. See EXHIBIT “B” for design/installation elevations.

Lessor will coordinate with the COE on the installation of these self-adhesive, vinyl graphics or where applicable, rough-surface applications.

EXHIBIT “B”

Marine Corps Wall Graphics

“MARINES” wall graphic is always placed on a large BLUE WALL. It is surface-applied, self-adhesive vinyl, color to PANTONE 451C, matte finish, a dark beige non-metallic color. Approved MARINES Wordmark Printed Vinyl: 3M 180CV3-10 opaque white vinyl, surface ink jet print to match PMS 451c (dark beige color) adjust as needed for accurate match to PMS 451. Surface laminated with 3M 8520 UV resistant matte clear overlay.

Alternate manufacturers (e.g., Arlon, Avery, GSP, OraCal, LG or other) sign vinyl materials equivalent to 3M 180 Series, rated for high bond wall application, and with minimum outdoor use 5-year warranty may be provided based on contractor recommendation.

Alternate MARINES Wordmark Color Vinyl Recommendation: Arlon 2100-3670 Beige, matt finish opaque vinyl.

The “Marines” graphic is always placed midway between head height (6’-0”) and the ceiling. It should be scaled to 80% of the length of the wall (up to 1’-8” H letters), and centered. The proportions of the provided “MARINES” artwork shall not be changed.

Note 1: Where length of walls exceed standards referenced above use Rule of Thumb: The letter height of the “MARINES” Wordmark should never grow so large that you can’t leave clear space above and below “MARINES” equal to the height of the letters, as measured from the work station panels to the ceiling.

Note 2: Wall mounted fixtures such as thermostats, wall switches, light sensors, emergency lighting, etc., should be placed free and clear of all Military Service accents walls.

“EGA” wall graphic is always placed on a RED WALL. It is surface-applied, self-adhesive vinyl, color to match PMS 4505c, matte finish, a dark yellow non-metallic color. Approved EGA Symbol Printed Vinyl: 3M 180CV3-10 opaque white vinyl surface ink jet print to match PMS 4505c (dark yellow color) adjust as needed for accurate match to PMS 4505. Surface laminated with 3M 8520 UV resistant matte clear overlay.

Alternate manufacturers (e.g., Arlon, Avery, GSP, OraCal, LG or other) sign vinyl materials equivalent to 3M 180 Series, rated for high bond wall application, and the minimum outdoor use 5-year warranty may be provided based on contractor recommendation.

Alternate EGA Symbol Color Vinyl Recommendation: Arlon 2100-3669 Olive, matt finish opaque vinyl.

It is to be scaled as large as possible with the top of the EGA high on the wall. Generally, the bottom is no more 3’-0” above the floor. If placed on a large wall where no fixtures or furniture will block it, the EGA should be made larger with the bottom closer to the floor.

Note 1: Red and blue walls require a minimum of four days (96 hours) for complete curing and drying time before application of vinyl wall graphics can occur. Paint drying time will be extended in cool or cold climates. Graphics contractor is to be advised of this requirement.

Note 2: Wall mounted fixtures such as thermostats, wall switches, emergency lighting, and light sensors, etc., should be placed free and clear of all Military Service accents walls.

Navy Recruiting Station located at 2274 S. Wrangleboro Road, Mays Landing, NJ ITEM 0005A:

PAINT INTERIOR OFFICE AREA(S)

1. Painting: Navy request to repair any visible damages in walls, nail holes and paint all interior office area(s). Contractor will be responsible for removing and replacing all furniture as required.

NAVY PAINT SCHEDULE

Color Name: Color #: Color: Coats: Finish: Area:

PRIMER ProMar 200 White (see Note 1)

B28W02600 1 Latex: Acrylic Primer

All Walls / All Painted Trim

United States Navy Recruiting White

SW 7757

High Reflective White B20W2650 2 Latex: Egg-Shell Walls

(above chair rail) United States Navy Recruiting

Blue

SW 9177

Salty Dog B20T2654 2 Latex: Semi-Gloss Walls

(below chair rail) United States Navy Recruiting

Gold

SW6903

Cheerful B31Y2657 2 Latex: Egg-Shell Chair Rail

United States Navy Recruiting White

SW 7757

High Reflective White B31W2650 2 Latex: Semi-Gloss Trim

Note 1: ProMar 200 Primer to be tinted to match the applicable wall color for all walls, and all painted trim.

Note 2: Paint schemes and wall finishes to be applied as referenced on floor plan/finish schedule.

Note 3: All window and door frames shall have semi-gloss finish; color to be: United States Navy Recruiting White.

Note 4: Walls to be: United States Navy Recruiting White above chair rail and

United States Navy Recruiting Blue below the chair rail Note 5: Chair Rail shall have semi-gloss finish; color to be: United States Navy Recruiting Gold Note 6: Restrooms: See Common Area Paint Schedule

ITEM 0005B: INSTALL CARPET TILES; INTERIOR OFFICE AREA(S)

a. Base Cove (for VCT & Carpet only): Johnsonite / Tarkett (https://distributor.tarkett.com), Rubber;

Color: #40, Black, 4” H.

b. Carpet Schedule (office, test room and related areas): Carpet tiles with base cove shall be installed throughout the entire office space except storage rooms, restrooms, common area lobbies, corridors, and exit areas. All carpet must be installed smoothly and evenly in accordance with manufacturer’s instructions and with the approved low Volatile

Organic Compounds (VOC’s) release adhesive. One (1) extra box of carpet tiles (for the Navy at this location) shall be left in the security closet for future use.

NAVY CARPET SCHEDULE

Manufacturer / Style: U.S. Navy Recruiting Standard: # 800G3 Color (Name, Number): Water Garden, 69400

Product: Carpet Tile Installation Method: Monolithic (See Note #1)

Note 1: Carpet tile installation to be installed monolithic with all arrows pointing in the left-direction upon walking into the entrance of the space.

ITEM 0005C – INSTALL “TRAINING WALL GRAPHIC” AND “HONOR, COURAGE, COMMITMENT WALL

GRAPHIC”

1. Interior Signage: GS w/guidance:

The Lessor shall order / install the Navy’s “Training Graphic” and “Honor, Courage, Commitment Graphic” below. Graphics to be centered vertically between the ceiling and chair rail and horizontally scaled to 65% - 70% of the length of the wall. Each graphic is to be made as one-piece with the size of the graphic not to exceed 4’ H x 18’ L. COE representative to supply the Navy’s wall graphic files. Lessor will coordinate with the COE on the installation of these self-adhesive, vinyl graphics or where applicable, rough-surface applications. Materials and instructions for installation are as follows:

a. Apply graphics to a flat smooth finish wall surface (after Navy paint is applied).

b. Allow paint a minimum of 96 hours drying time before applying any wall graphics.

c. Navy’ wall graphic shall be printed on and surface-applied to the self-adhesive vinyl. Printed Vinyl: 3M 180CV3-10 opaque white vinyl, surface ink jet printed with the Navy’ graphics. Surface laminated with 3M 8520 UV resistant matte clear overlay.

d. Alternate manufacturers (e.g., Arlon, Avery, GSP, OraCal, LG or other) sign vinyl materials equivalent to 3M 18 Series, rated for high bond wall application, and with minimum outdoor use 5-year warranty may be provided based on contractor recommendation.

e. Note 1: Wall mounted fixtures such as thermostats, wall switches, emergency lighting, and light sensors, etc., should be placed free and clear of all military service accents walls and graphics.

f. Selected, for expedited delivery-government pricing contact:

Manufacturer: Fastsigns, Inc.

POC: Chip Fullerton – General Manager Phone:

(901) 725-7446 Email: 81@fastsigns.com

Model: 3M 180CV3-10 Opaque White Vinyl wall covering Substrate: Equal to 3M 180CV3-10 Opaque White Vinyl wall covering or better.

Installation: Utilize manufacturers’ recommended products in accordance with 3M 180CV3-10 Opaque White Vinyl wall covering installation instructions and surface preparation and adhesive guidelines. Clean the wall with a mixture of 70 percent isopropyl alcohol and 30 percent water. Do this two times. Cleaning with this mixture will increase adhesion on Low VOC paints. Lessor to install the graphics according to manufacturer’ instructions in order to maintain their warranty requirements.

Graphics: a) “Training Wall Graphic” to be installed per approved Floorplan:

mailto:81@fastsigns.com

b) “Honor, Courage, Commitment Wall Graphic” to be installed per approved Floorplan (opposite the Training Graphic):

Army Recruiting Station located at 818 Haddonfield Road, Cherry Hill, NJ

ITEM 0006A – PAINT ALL INTERIOR OFFICE AREAS, INCLDUING TESTING ROOM (ARMY

OFFICE ONLY).

1. Painting: Army request to repair any visible damages in walls, nail holes and paint all interior office area(s). Contractor will be

PRIMER ProMar 200 White (see Note 1) B28W02600 1 Latex: Acrylic

Primer All Walls / All Painted Trim

United States Army Recruiting Off-White SW 6148 Wool Skein B20W12651 2 Latex: Egg-Shell Walls

United States Army Recruiting Khaki SW 6150 Universal Khaki B31W2651 2 Latex: Semi-Gloss Trim

United States Army Recruiting Green SW 6166 Eclipse B20T2654 2 Latex: Egg-Shell Accent Wall

Note 1: ProMar 200 Primer to be tinted to match the applicable wall color for all walls, and all painted trim.

Note 2: Paint schemes and accent wall finishes to be applied as referenced on floor plan/finish schedule.

Note 3: All window and door frames shall have semi-gloss finish; color to be: United States Army Recruiting Khaki.

Note 4: Accent wall to be: United States Army Recruiting Green Note 5: Restrooms: See Common Area Paint Schedule

ITEM 0006B FLOORING REQUIREMENT (ARMY OFFICE ONLY) – REPLACE

ALL CARPET TILES; INTERIOR OFFICE AREA(S)

a. Base Cove (for VCT & Carpet only): Johnsonite/Tarkett (https://distributor.tarkett.com), Rubber; Color: #40, Black, 4” H.

b. Carpet Schedule (office, and related areas): Carpet tiles with base cove shall be installed throughout the entire space except storage rooms, restrooms, common area lobbies, corridors, and exit areas. All carpet must be installed smoothly and evenly in accordance with manufacturer’s instructions and with the approved low Volatile Organic Compounds (VOC’s) release adhesive. One (1) extra box of carpet tiles (for the Army at this location) shall be left in the security closet for future use.

Manufacturer/Style: U.S. Army Recruiting Standard: # 802E5 Color (Name, Number): Duty, BB90D Product: Carpet Tile

Army Recruiting Battalion located at Joint Base MDL, HWY 547, Lakehurst, NJ ITEM 0007A

– PAINT ALL INTERIOR OFFICE AREAS, HALLWAY INCLUDING THE

STORAGE ROOM & GENERAL WAREHOUSE (ARMY OFFICE

ONLY).

2. Painting: Army request to repair any visible damages in walls, nail holes and paint all interior office area(s). Contractor will be

PRIMER ProMar 200 White (see Note 1) B28W02600 1 Latex: Acrylic

Primer All Walls / All Painted Trim

United States Army Recruiting Off-White SW 6148 Wool Skein B20W12651 2 Latex: Egg-Shell Walls

United States Army Recruiting Khaki SW 6150 Universal Khaki B31W2651 2 Latex: Semi-Gloss Trim

United States Army Recruiting Green SW 6166 Eclipse B20T2654 2 Latex: Egg-Shell Accent Wall

Note 1: ProMar 200 Primer to be tinted to match the applicable wall color for all walls, and all painted trim.

Note 2: Paint schemes and accent wall finishes to be applied as referenced on floor plan/finish schedule.

Note 3: All window and door frames shall have semi-gloss finish; color to be: United States Army Recruiting Khaki.

Note 4: Accent wall to be: United States Army Recruiting Green Note 5: Restrooms: See Common Area Paint Schedule

ITEM 0007B FLOORING REQUIREMENT (ARMY OFFICE ONLY) – REPLACE ALL

CARPET TILES; INTERIOR OFFICE AREA(S)

a. Base Cove (for VCT & Carpet only): Johnsonite/Tarkett (https://distributor.tarkett.com), Rubber; Color: #40, Black, 4” H.

b. Carpet Schedule (office, and related areas): Carpet tiles with base cove shall be installed throughout the entire space except storage rooms, restrooms, common area lobbies, corridors, and exit areas. All carpet must be installed smoothly and evenly in accordance with manufacturer’s instructions and with the approved low Volatile Organic Compounds (VOC’s) release adhesive. One

(1) extra box of carpet tiles (for the Army at this location) shall be left in the security closet for future use.

Manufacturer/Style: U.S. Army Recruiting Standard: # 802E5 Color (Name, Number): Duty, BB90D Product: Carpet Tile

Marines Recruiting Station located at 10 S. Haddon Avenue, Haddonfield, NJ

ITEM 0008A – INSTALL SMART DIGITAL THERMOSTAT ENERGY STAR RATED

1. HVAC General:

a. Install one (1) smart thermostat energy star rated in Marines Office Area as the Marines office has no thermostat to control and adjust the room temperature. A Smart thermostat is to be installed.

b. The HVAC system, will be designed and provide temperature controlled thermostats in each individual Military Service office. The contractor will coordinate with the COE on the determination of acceptable thermostat(s). A digital, 7-day programmable, code-protected thermostat shall be utilized. Thermostat’s to be mounted in the Marines Office “open office” area(s).

b. Wall mounted fixtures such as thermostats, wall switches, light sensors, emergency lighting etc., should be placed free and clear of all Military Service accent walls.

ITEM 0008B – REMOVE AND INSTALL TEST ROOM FULL-LENGTH GLASS DOOR

1. Interior Doors:

a. Interior Doors: Shall be a flush panel solid core wood door with maple veneer and Grade 2 hardware or better.

b. Frames / Glass / Finish:

i. Interior door and window frames to be Timely manufactured steel Classic S-Series (445) frames with factory applied Alumatone finish (not painted).

ii. Door color to be stained MinWax, Red Chestnut #232 (on all sides) with two (2) coats of polyurethane matte finish to be applied to stained areas.

iii. Doors requiring a full length glass inset (low profile lite kit [24” x 60”] with ¼” tempered glass), shall color match the Timely manufactured steel frames (factory applied Alumatone color SC108) or brushed stainless steel finish.

c. The following door opening hardware schedule and specifications shall apply:

Door Openings (Doors / Hardware) Schedule & Specifications

INTERIOR:

Application: Model / Skew #’s: Description: Size: Finish: Qty: Set Codes:

HARDWARE SET

DESCRIPTIONS:

Test Room Door:

Varies Solid Core Flush Wood Door & Full Length Glass Inset

1-¾” x 36” x 80”

See Notes Ea

I4

Notes:

Classic S-Series (Timely Code 445)

Timely Manufactured Frame with pre-drilled holes & silencers

36” x 80” Alumatone Ea Door & window frames to match

TA2714-USA-

US26D McKinney - Hinges 4-1/2” x

4-1/2” Satin

Chrome

B-TB-4601LN-

626 Yale – Passage Latch

N/A

Satin

Chrome

B-UB-4601LN-

if local code requires return

ITEM 0008C – REMOVE AND INSTALL NEW SOLID DOOR (TO COMMON AREA(S) FROM OFFICE ONLY)

1. Interior Doors:

a. Interior Doors: Shall be a flush panel solid core wood door with maple veneer and Grade 2 hardware or better.

b. Frames / Glass / Finish:

c. Interior door and window frames to be Timely manufactured steel Classic S-Series (445) frames with factory applied Alumatone finish (not painted).

d. Door color to be stained MinWax, Red Chestnut #232 (on all sides) with two (2) coats of polyurethane matte finish to be applied to stained areas.

e. Doors requiring a full length glass inset (low profile lite kit [24” x 60”] with ¼” tempered glass), shall color match the Timely manufactured steel frames (factory applied Alumatone color SC108) or brushed stainless steel finish.

f. The following door opening hardware schedule and specifications shall apply:

HARDWARE SET DESCRIPTIONS:

Application: Model / Skew #’s: Description: Size: Finish: Qty: Set Codes: Notes:

Service Interior Entrance Doors (w/in Gov’t controlled leased premises):

Varies Solid Core Flush Wood Door

Full Length Glass Inset

1-¾” x 36” x

I1

Notes 2, 3 and 4

Classic S-Series (Timely Code 445)

Timely Manufactured Frame with pre-drilled holes & silencers

36” x 80” Alumatone Ea Door & window frames to match

TA2714-USA-

US26D McKinney - Hinges 4-1/2” x

4-1/2” Satin

Chrome

B-TB-4607LN-626 Yale – Entry Lever Cylinder Lockset

Satin

Chrome

B-UB-4607LN-

if local code requires return

A600-626 Yale – SFIC Core (7-Pin) N/A Satin Chrome

K1050-CSK-630 Rockwood – Kick Plate 10” Satin SS 2

CD-80-065 Hunter Douglas Contract CD Series Aluminum Mini-Blinds

1” Brushed Aluminum

1 Notes 2, 3 and 4

NOTES & ADDITIONAL REQUIREMENTS FOR EXTERIOR & INTERIOR DOORS & HARDWARE:

1) Exterior Egress Doors:

a. Lessor Shell Requirements / Exterior Door Health Survey: Exterior door openings to the Government controlled space shall be surveyed to ensure a healthy, weather tight and fully functional door unit (door, frame, glass, and hardware). Door opening / swing to be outswing only, fail secure with Grade 1 hardware and no mail slots allowed. Existing mail slots in exterior doors shall be removed. Survey / coordinate hardware requirements on existing doors / frames to be re- used. Clean, repair or replace as necessary - advise COE representative if existing door / hardware needs to be replaced.

b. Hinge pins for exterior doors to be concealed / non-removable (existing to remain if meets requirements).

c. DON-JO Door Strengtheners: www.don-jo.com (door / hardware specific as needed for long term proper door usage

(connectivity of video intercom entry control (EC) system components), As determined by EC system contractor (e.g. - wrap around plate; inactive door wrap around strike prep; hinge side wrap around reinforcement; mortise lock wrap around; door reinforcer [deadbolts & key- in-knob locks]).

d. See paragraph G.9.ii: Hunter Douglas – Fixed Panel Shade (absolutely no mini-blinds on exterior doors).

e. See paragraph G.6. & G.7: 3M – Fragment Retention Film (required for ALL glass in doors and windows on the perimeter of Government controlled leased premises).

f. Additional door types (non-standard / double doors / all glass Herculite doors) confirm with COE (located in Appendix C).

2) Interior Doors:

a. To be flush panel solid core wood door, maple veneer, stained with MinWax Red Chestnut #232 (all sides); with two (2) coats of polyurethane matte finish applied to stained areas.

b. Metal Frames (for doors & windows): Interior door and window frames to be Timely manufactured steel frames with factory applied

Alumatone aluminum / silver finish (not painted). For doors with a full length tempered glass inset (24” x 60”), finish to match the Timely frames “Alumatone” aluminum / silver finish metal frame. See paragraph G.6. & G.7 for full details.

c. Grade 2 hardware or better required. Specifications are for no return handles. If required by local code, door handles with a return may be substituted.

d. Doors to include a Rockwood (403-626 satin chrome) convex rubber door stop/bumper.

e. Security Closet ONLY Options:

I. Flush panel wood finished door.

II. Flush panel wood finished door with full length “louvered” inset – if increased Security Closet ventilation is required.

III. Flush panel wood finished pocket door – may be installed to minimize space requirements (no swing taking up space).

f. Mini-Blinds: Interior doors & windows to have mini-blinds, except for Test / Interview rooms. Must be secured at the bottom of doors with metal clips.

3) Keying or Re-Keying: Before delivery and acceptance of the premises, all previous existing exterior door-locks shall be re-keyed.

The Lessor will be responsible for coordinating with the COE on the number of new keys required to be furnished to each Military Service. EACH individual Military Service office shall be separately keyed. Note: Both front and rear exterior exit doors for each Military Service should be same-keyed. Keys to be minimized / same-keyed for each Military Services primary and secondary egress doors, interior common area doors, security closet and each Military Service specific interior doors (excluding Station Commanders Offices). Station Commanders Offices shall be separately keyed. If fire department Knox Box is required, a key must be provided. See also paragraph A.4 regarding the number of recruiters needing keys.

4) Acronym Legend:

a. SS = Stainless Steel.

b. Ea = Each.

c. � = Electrified component.

http://www.don-jo.com/

ITEM 0008D – INSTALL NEW DUAL ROLLER SHADE

1. Exterior Windows / Doors:

a. Roller Shades: ALL exterior windows shall have roller shades installed. WHEN INSTALLED, SHADES SHALL NOT ALLOW

FOR ANY VISUAL GAPS.

b. Roller Shades (windows only): The Lessor will coordinate with the COE as to whether single roller shades are required.

c. Single or Dual shades to be Hunter Douglas Architectural, Contract Roller Shade: Model #RB500 or equivalent. Fascia & End Cap finishes to be “anodized aluminum”. These shades will not require military logos. To ensure a uniform appearance, all window shades will be motorized, with an appropriate electric wall keypad / switch control(s) for multiple shades, as identified on the floor plan / AE drawing (installed at rear of each Military Service facility). Each switch / keypad to be labeled. NOTE: BATTERY OPERATED KEYPADS ARE NOT ALLOWED. Roller Shade couplers will be used to minimize the number of motors and electrical drop(s) required (up to 300” in length and/or 6 roller shades). All electrical power to be hardwired within conduit inside walls. Shades shall NOT be installed inside the window frame (in order to connect multiple roller shades together with a single motor). Motor to be, Sonesse Ultra model # 50 RA with a sound level equivalent to an office conversation. Installation shall be as per manufacturer’s written instructions ~ to include all necessary blocking and structural supports. Shades to include the required number of Individual Group Control (IGC) 4N1 motor controls (mounted above window, within ceiling, near front door when possible) with a HARDWIRED DecoFlex dry contact keypad / switch (located as identified on floor plan / AE drawing). Shades will have a lifetime warranty and pass the NFPA 701 Small Scale test. If window(s) cannot be equipped with roller shades, either because of their unique shape and/or the inability to install the shade correctly, then only with expressed prior approval of the COE, a fixed panel shade shall be applied in accordance with fixed panel specifications below. If already installed, existing glass block requires no window covering. For wiring diagrams, see ENCLOSURES # 4a, 4b, 4c, 4d and 4e

d. Dual Roller Shades (windows only): Dual Roller shades will be installed when an exterior perforated window wrap IS NOT or WILL NOT be applied to the exterior windows. Shades to have both ‘Sheer’ and ‘Privacy’ fabrics. The ‘Sheer Shade’ shall be of a fabric equal to Hunter Douglas E Screen 3% White / White to be closest to the window. The ‘Privacy Shade’ shall be fabric equal to Hunter Douglas SheerWeave 7100 White. If the 7100 fabric is not available, the alternate fabric to be SheerWeave 7400 Cotton.

Note: If a dual shade application is required, it may be necessary to install two individual shades if existing window conditions do not allow enough room to accommodate a dual shade bracket.

ENCLOSURE # 4a, 4b, 4c, 4d and 4e

GENERAL STANDARD (GS)

Dual Roller Shade Wiring Diagrams

IGC4N1

MULTIPLE MOTOR

CONTROLLERS WITH

MASTER KEYPAD

DUAL SHADE

APPLICATION

AC POWER 3-WIRE

DRY CONTACT KEYPAD

CONNECTION VIA CAT 6 14/4

Wire 120V FROM EACH MOTOR

TO 4N1

E-screen/Sheer (Solar) Shades SheerWeave Opaque (Blackout) Shades 14/4 Wire consists of

Hot (Di"ection 1) Hot (Di"ection 2) Neu tral Gro und

CAT 6 Pinout

Set your dip switches to d e configuration.

See IGC 4N1

MOTOR

CONIROILF

R instructions for further details NOTE: Each IGC 4Nl controller controls up to 4 motors/shad es and can be used for single or dual shade configuratio ns.

This drawing represents how to set up for facilities with more than 4 motors.

tCWltr.clwtou.s dry cmib.cl C<JWll!Ctiouhyp.d tocmJ.lro!

mulhpl IGC 4NI' using th..mrli,r inpul:All'l!l.lde,;willfunciio nasa grou;imd'oc ·-

Master Keypad(s} / Switches Dual Roller Shades Enclosure #4c

Close Up View of the IGC 4Nl Motor Controller:

Enclosure #4d

·1 :;o

= Roller l IPR I 1 I

1 4

Accent Wall ' Marines -r

I '

@ Air Force

Enclosure #4e trr

11'- 9"

11'-10" I

/ - I 16'-4" 12'-2"

I I i Storage 1°1'-3" X l:?.'-7"

Shades I L- "iTci

Test...

I 1Pa' ... .:- :·:::::-.. ; I lb.l I Office

11111 = Fixed Panel I 111 6'-11. x 6' Shades

■ = Roller Shade

;o• e.-j1 el :1

Controller (Somfy)

= Junction

C, Army 23' X 25' 8"

I

. [; I

Navy 23'-4" X 25'-9"

! Box(above I II / drop ceiling)

I [ wmng

Thiswindowcouldbe aroller shadeor fixedpanelbasedonthesttuations and 1• dthof thev ndowI sideliteby thedoor.

'( _.... ,r I - I 5'-2" X 17'-7"

I

\ (i? 7'x11'-1"

= Dual Roller

Shade Controller 15'-6" X 17'-7" \of,>I !

S

ITEM 0008E – INSTALL NEW ENTRY BELL/CHIME-WIRE/MECHANICAL ABOVE EXTERIOR MAIN ENTRANCE DOOR

1. Security general:

a. Install new entry bell/chime-wire/mechanical above exterior main entrance door.

Entry Bell: For existing / retrofit locations, the following entry bell types may be required:

1. Hard-wired entry alert door chime to all front, and secondary exterior doors. NO WIRELESS and/or BATTERY OPERATED

CHIMES ALLOWED. The system shall be installed to ensure the door chime is operated by the opening of the door and shall have a tone acceptable for an office environment and must be audible in all collocated Military Services’ offices. The COE will approve the proposed tone of the chime before installation. The main entry chime shall have a single-tone ping (e.g. - “ding”) while the secondary exit door chimes shall have a two-tone ping (e.g.

- “ding-dong”).

2. If site specific conditions require a non-electrical door chime, a fully mechanical system (no electrical wiring) is allowed, as long as each Military Service can hear them in their offices. Alternate mechanical / magnetic entry bell chime to be: EZ-Tone, model # ADC-01. Color to closely match existing door frame when possible. Confirm with COE representative on use and color.

Note: Door position switches to activate shared egress door chime. Primary shared egress doors shall have a single-tone (e.g. - “ding”), and secondary egress door(s) shall have two-tones (e.g. - “ding-dong”).

Army Recruiting Station located at 3333 Route 9 North, Freehold , NJ ITEM

0009A: ARMY OFFICE ONLY – PAINT REQUIREMENT

1. Painting: Paint all interior office area(s).

a. Army request to repair any visible damages in walls, nail holes and paint all interior office area(s). Contractor will be

PRIMER ProMar 200 White (see Note 1)

B28W02600 2 Latex: Acrylic Primer All Walls / All Painted Trim

United States Army Recruiting Off-White SW 6148 Wool Skein B20W12651 2 Latex: Egg-Shell Walls

United States Army Recruiting Khaki SW 6150 Universal Khaki B31W2651 2 Latex: Semi-Gloss Trim

United States Army Recruiting Green SW 6166 Eclipse B20T2654 2 Latex: Egg-Shell Accent Wall

Note 1: ProMar 200 Primer to be tinted to match the applicable wall color for all walls, and all painted trim.

Note 2: Paint schemes and accent wall finishes to be applied as referenced on the approved floor plan / AE drawing / finish schedule.

Note 3: Accent wall to be: United States Army Recruiting Green.

Note 4: Restrooms: See Common Area Paint Schedule.

ITEM 0009B: CARPET INSTALLATION

a. Army request to remove all old carpet tiles in interior office area(s) and installing new carpet tiles in all interior office area(s).

b. Contractor will be responsible for removing and replacing all furniture as required.

c. Base Cove (for VCT & Carpet only): Johnsonite/Tarkett (https://distributor.tarkett.com), Rubber;

Color: #40, Black, 4” H.

d. Carpet Schedule (office, test room and related areas): Carpet tiles with base cove shall be installed throughout the entire space except storage rooms, restrooms, common area lobbies, corridors, and exit areas. All carpet must be installed smoothly and evenly in accordance with manufacturer’s instructions and with the approved low Volatile Organic Compounds (VOC’s) release adhesive. One (1)extra box of carpet tiles (for the Army at this location) shall be left in the security closet for future use.

Color (Name, Number): Duty, BB90D Product: Carpet Tile

Marines Recruiting Station located at 3333 Route 9 North, Freehold, NJ

ITEM 00010A: INSTALL CARPET TILES; INTERIOR OFFICE AREA(S (MARINES OFFICE

ONLY)

1. Flooring: Remove old carpet tiles and install new carpet tiles; interior office area(s).

a. Base Cove (for VCT & Carpet only):…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .