This is a solicitation from the Department of the Army Corps of Engineers Engineering District Walla Walla seeking quotes for unwatering/dewatering pumps and motors for McNary Dam in accordance with the specified technical requirements. Key details include a request for two vertical mixed flow impeller line shaft pumps capable of 12,000 GPM at 40 feet TDH, with 200 HP electric motor drivers, to be delivered by 50 weeks after submittal approval. Quotes are due by 2:00 PM on September 14, 2023. The solicitation also requires a chamber dewatering pump and motor spare parts kit and adherence to documentation, testing, packaging, and shipping standards. Responses should be submitted to the identified contracting officer via email.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SEE ADDENDUM

(No Collect Calls)

W912EF23Q0091 24-Aug-2023

b. TELEPHONE NUMBER

509-527-7217

8. OFFER DUE DATE/LOCAL TIME

02:00 PM 14 Sep 2023

5. SOLICITATION NUMBER 6. SOLICITATION ISSUE DATE

AUTHORIZED FOR LOCAL REPRODUCTION

PREVIOUS EDITION IS NOT USABLE

STANDARD FORM 1449 (REV. 2/2012)

Prescribed by GSA – FAR (48 CFR) 53.212

(TYPE OR PRINT)

(SIGNATURE OF CONTRACTING OFFICER)

ADDENDA X ARE

26. TOTAL AWARD AMOUNT (For Gov t. Use Only )

23.

CODE 10. THIS ACQUISITION IS

SUCH ADDRESS IN OFFER

17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT

BELOW IS CHECKED

TELEPHONE NO.

W912EF9. ISSUED BY

18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a. UNLESS BLOCK

7. FOR SOLICITATION

INFORMATION CALL:

a. NAME

ALAN N INGLIS

2. CONTRACT NO. 3. AWARD/EFFECTIVE DATE 4. ORDER NUMBER

(TYPE OR PRINT)

30b. NAME AND TITLE OF SIGNER 30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER

30a. SIGNATURE OF OFFEROR/CONTRACTOR 31a.UNITED STATES OF AMERICA

1 27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1. 52.212-4. FAR 52.212-3. 52.212-5 ARE ATTACHED.X

25. ACCOUNTING AND APPROPRIATION DATA

1. REQUISITION NUMBER

20.

ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED.

OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, AND 30

SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS

ARE NOT ATTACHED

27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA ARE ARE NOT ATTACHED

(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE

SET FORTH HEREIN, IS ACCEPTED AS TO ITEMS:

. YOUR OFFER ON SOLICITATION

28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN

% FOR:SET ASIDE:UNRESTRICTED OR X

SMALL BUSINESSX

17a.CONTRACTOR/ CODE FACILITY

OFFEROR CODE

USAED, WALLA WALLA - CONTRACTING DIV.

ALAN INGLIS

201 N. THIRD AVENUE

WALLA WALLA WA 99362-1876

18a. PAYMENT WILL BE MADE BY CODE

RATED ORDER UNDER

DPAS (15 CFR 700)

13a. THIS CONTRACT IS A

13b. RATING

CODE15. DELIVER TO CODE 960401 16. ADMINISTERED BY

12. DISCOUNT TERMS11. DELIVERY FOR FOB DESTINA-

TION UNLESS BLOCK IS

MARKED

SEE SCHEDULE

14. METHOD OF SOLICITATION

RFQ IFB RFPX

ARMY CORPS OF ENGINEERS

PERFORMANCE SPECIALIST

MCNARY PROJECT WHSE

82790 DEVORE ROAD

UMATILLA OR 97882-1230

TEL: 541-922-1355 FAX: 541-922-2221

FAX:

TEL: 509-527-7217 SERVICE-DISABLED

VETERAN-OWNED

SMALL BUSINESS

8(A)

HUBZONE SMALL

BUSINESS

SIZE STANDARD:

1,250

NAICS:

333996

X

OFFER DATED

29. AWARD OF CONTRACT: REF.

DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY

COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND

EMAIL:

TEL:

31c. DATE SIGNED

SEE SCHEDULE

SCHEDULE OF SUPPLIES/ SERVICESITEM NO. QUANTITY UNIT UNIT PRICE AMOUNT

24.22.21.19.

WOMEN-OWNED SMALL BUSINESS (WOSB)

ELIGIBLE UNDER THE WOMEN-OWNED

SMALL BUSINESS PROGRAM

EDWOSB

32g. E-MAIL OF AUTHORIZED GOVERNMENT REPRESENTATIVE

SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS

(CONTINUED)

PAGE 2 OF42

ACCEPTED, AND CONFORMS TO THE CONTRACT, EXCEPT AS NOTED: ______________________________________________________

32a. QUANTITY IN COLUMN 21 HAS BEEN

RECEIVED INSPECTED

32b. SIGNATURE OF AUTHORIZED GOVERNMENT

REPRESENTATIVE

32c. DATE 32d. PRINTED NAME AND TITLE OF AUTHORIZED GOVERNMENT

REPRESENTATIVE

32e. MAILING ADDRESS OF AUTHORIZED GOVERNMENT REPRESENTATIVE 32f . TELEPHONE NUMBER OF AUTHORIZED GOVERNMENT REPRESENTATIVE

37. CHECK NUMBER

FINALPARTIALCOMPLETE

36. PAYMENT35. AMOUNT VERIFIED

CORRECT FOR

34. VOUCHER NUMBER

FINAL

33. SHIP NUMBER

PARTIAL

38. S/R ACCOUNT NUMBER 39. S/R VOUCHER NUMBER 40. PAID BY

41a. I CERTIFY THIS ACCOUNT IS CORRECT AND PROPER FOR PAYMENT

41b. SIGNATURE AND TITLE OF CERTIFYING OFFICER 41c. DATE

42a. RECEIVED BY (Print)

42b. RECEIVED AT (Location)

42c. DATE REC'D (YY/MM/DD) 42d. TOTAL CONTAINERS

STANDARD FORM 1449 (REV. 2/2012) BACK

Prescribed by GSA – FAR (48 CFR) 53.212

AUTHORIZED FOR LOCAL REPRODUCTION

PREVIOUS EDITION IS NOT USABLE

SEE SCHEDULE

20.

SCHEDULE OF SUPPLIES/ SERVICES

21.

QUANTITY UNIT

22. 23.

UNIT PRICE

24.

AMOUNT

19.

ITEM NO.

W912EF23Q0091

Section SF 1449 - CONTINUATION SHEET

INSTRUCTIONS TO OFFERORS

This is a request for quote for Unwatering/Dewatering Pumps and Motors in accordance with the technical specifications for the U.S. Army Corps of Engineers, Walla Walla District, at McNary Dam, Umatilla, OR.

Completion of the required FAR 52.212-3, Offeror Representations and Certifications – Commercial Items is required. When you complete your SAM registration, the link to complete your Representations and Certifications is also available. Please do not hesitate to contact Alan Inglis, or the SAM website for assistance or have questions.

TO ENSURE RECEIPT OF YOUR QUOTE, PLEASE SEND TO THE ATTENTION OF ALAN INGLIS

AT alan.n.inglis@usace.army.mil .

Please return all pages of this request for quote. Be sure to also complete Blocks 17a, 30a, 30b, and 30c on page 1.

Name: _____________________________________________________________

Contact Telephone Number: ____________________________________________

Email Address: __________________________________________________________________

Company’s Federal Tax Identification Number: ____________________________________________

CAGE CODE: ________________________ SAM Unique ID: ________________________________

Total Amount of Contract: ____________________________

Completion of FAR 52.212-3 Offeror Representations and Certifications–Commercial Items – Alternate 1 (May 2014). Electronic completion is encouraged (see http://farsite.hill.af.mil to download Representations and Certifications).

An offeror shall complete only paragraph (b) of this provision if the offeror has completed the annual representations and certifications electronically via https://www.acquisition.gov. If an offeror has not completed the annual representations and certifications electronically at www.sam.gov, the offeror shall complete only paragraphs (b) through (i) of this provision.

In accordance with FAR Part 29.3 – State and Local Taxes, and per Title 4 of US Code 104-107, the Government is exempt from paying state and local taxes. Exempt tax identification number 91-0828090.

ADDENDUM TO FAR 52.212-1 INSTRUCTIONS TO OFFERORS – COMMERCIAL ITEMS

Submission of Price Quote – Offeror shall submit 1 copy of the following:

1. Signed and dated Standard Form 1449 (Solicitation/Contract/Order for Commercial Items)

2. Signed and dated Standard Form 30, if applicable, for any Amendments to the Solicitation

3. Completed schedule (pricing information) for all contract line-item numbers

4. Completed Clause 52.212-3 Alt I, “Offeror Representations and Certifications—Commercial Items” as noted above. See Technical Specifications Section 4.3.1.2 for submittal of ISO certificate.

PRICES QUOTED MUST BE VALID FOR 30 DAYS. Solicitation shall result in a firm-fixed-price contract.

All pricing shall include shipping FOB destination (include shipping cost in price).

BUSINESS HOURS: The standard business hours for the Walla Walla District, Corps of Engineers are

Monday through Friday from 8:00 a.m. to 4:00 p.m., excluding federal holidays.

BASIS FOR AWARD

The Government will award one contract resulting from this solicitation in accordance with FAR 13.106 to the responsible offeror meeting or exceeding all solicitation requirements and representing the best value based on price.

Bidder Inquiry:

All inquiries regarding this solicitation are to be submitted via Bidder Inquiry. Telephone and email inquiries will not be accepted. Bidder Inquiry is a web-site that allows bidders to post questions regarding the solicitation and view all questions by other bidders and responses by USACE. Bidder Inquiry can be accessed through ProjNet at (https://www.projnet.org)

To submit and review inquiry items, prospective vendors will need to use the Bidder Inquiry Key presented below and follow the instructions listed below the key for access. A prospective vendor who submits a comment /question will receive an acknowledgement of their comment/question via email. Another email to the same address will notify the prospective vendor once the reply is available for viewing.

TIMING OF BIDDER INQUIRIES: Bidders are encouraged to submit their bidder inquiries promptly. The Government will make every effort to answer all bidder inquiries; however, the closer to the bid or proposal due date an inquiry is received, the less likely it is that a timely response can be provided. Projnet for this inquiry will close 4:00 pm on 7 September 2023; even though, the close date to submit quotes is after this date.

The Bidder Inquiry Key is: ZWZWFS-QVXHPD

Specific Instructions for ProjNet Bid Inquiry Access:

1. From the ProjNet home page linked above, click on Quick Add on the upper right side of the screen.

2. Identify the Agency. This should be marked as USACE.

3. Key. Enter the Bidder Inquiry Key listed above.

4. Email. Enter the email address you would like to use for communication.

5. Click Continue. A page will then open saying that a user account was not found and will ask you to create one using the provided form.

6. Enter your First Name, Last Name, Company, City, State, Phone, Email, Secret Question, Secret Answer, and Time Zone. Make sure to remember your Secret Question and Answer as they will be used from this point on to access the ProjNet system.

7. Click Add User. Once this is completed you are now registered within ProjNet and are currently logged into the system.

Instructions for Entering Questions:

1. After you are logged in click on the "post new inquiry", it is on the left side of the window under the Word "Submit" a.) This is the window where you will enter your questions b.) Comment Classification: Click on the down arrow to the right of the words “Please select from below”, select “Public” c.) Discipline: This is where you select who this question should be directed to. Example; if the question is about an electrical drawing or specification select: “Electrical” from the pull down list.

d.) Sheet. Enter the sheet number of the drawing you are asking about.

e.) Detail. Enter the detail name of the detail shown on the drawing that you are asking about.

f.) Specification. Enter the Specification number and paragraph number.

g.) File. Use this if you are going to attach a pdf file.

h.) Question. Enter your question here.

Specific Instructions for Future ProjNet Bid Inquiry Access:

1. For future access to ProjNet, you will not be provided any type of password. You will utilize your Secret Question and Secret Answer to log in.

2. From the ProjNet home page linked above, click on Quick Add on the upper right side of the screen.

3. Identify the Agency. This should be marked as USACE.

4. Key. Enter the Bidder Inquiry Key listed above.

5. Email. Enter the email address you used to register previously in ProjNet.

6. Click Continue. A page will then open asking you to enter the answer to your Secret Question.

7. Enter your Secret Answer and click Login. Once this is completed you are now logged into the system.

For questions about the ProjNet Bidder Inquiry, please contact the Call Center help desk toll free at 1-800-428- HELP, which operates from 8AM to 5PM (Central US time zone). Bidder inquiry help questions can also be emailed to the helpdesk at staff@projnet.info

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

MCNARY LOCK AND DAM

UNWATERING/DEWATERING PUMPS & MOTORS

1.0 INTENT

The following specifications pertain to the purchase of mechanical items that will be used to upgrade the pumping capability for the unwatering, dewatering, and air systems in the downstream sump at the Navigation Lock. McNary Project staff will install the items listed below.

2.0 SCOPE

The Contractor shall be required to deliver the mechanical items to McNary Dam by the date shown in Section 6.0 Delivery Requirements. The Contractor shall provide documentation and other items as stated in the specifications.

3.0 MECHANICAL ITEM REQUIREMENTS

3.1 Vertical Mixed Flow Impeller Lineshaft Pump for Chamber Dewatering, Portable.

3.1.1 Model Description: 12,000 GPM @ 40 Ft TDH, 1185 RPM, Minimum 87.2% Bowl Efficiency, Maximum 33 Ft. NPSHR.

3.1.2 Vertical, Above Grade Discharge, 20” Diameter Pipe, 42’-2” pump length of baseplate to the Miter Gate Lower Sill. Depth of Suction Chamber is 6’-0”.

3.1.3 Electric Motor Driver: 200 HP @ 1200 RPM. 460V/3Ph/60Hz.

3.1.4 Single Stage, Mixed Flow Impeller, Product Lubricated, Wet Pit, Vertical Segmented Line Shaft

Pump. No oil/grease bearings permitted.

3.1.5 Each pump selected to provide specified flow while operating against specified total dynamic head at operating speed and operating conditions specified.

3.1.6 Complete pump unit when operating within specified operating range shall be free of excessive vibration, cavitation, and noise.

3.1.7 Pumps and electric motor drivers shall be furnished by the pump manufacturer.

3.1.8 Surface preparation and coating: All non-stainless-steel components shall have surface preparation to white metal blast cleaning, SSPC-SP5, to a profile depth of 1.5 mils and coated to 12 mils thick of a high solid, polyamide cured two-part epoxy paint, Jotamastic 90 AI or similar, using an airless sprayer.

3.1.9 Additional pump and motor requirements listed in Paragraph 4.0. NAVLOCK PORTABLE

CHAMBER DEWATERING PUMPS.

3.1.10 Quantity of TWO (2) pumps each.

3.2 Chamber Dewatering Pump and Motor Spare Parts, Kit. The KIT will include the following.

3.2.1 ONE (1) complete Pump Bowl Assembly with bowl shaft and impeller.

3.2.2 ONE (1) set of intermediate bearing retainers for one pump.

3.2.3 A FULL set of shaft bearings for TWO (2) pumps.

3.2.4 A FULL set of pump shaft couplings for ONE (1) pump.

3.2.5 TWO (2) additional stuffing box bearings.

3.2.6 ONE (1) complete stuffing box assembly.

3.2.7 50% (Percent) of all flange fasteners per pump model.

3.2.8 FOUR (4) sets of spare packing for both pumps. Precision cut (Per Set) and stored inside hard cardboard tubing.

3.2.9 ONE (1) set of electric motor bearings.

4.0 NAVLOCK PORTABLE CHAMBER DEWATERING PUMPS

4.1 SCOPE

4.1.1 This specification covers the two (2) Electric Motor Driven, Vertical Mixed Flow Impeller Lineshaft Pumps for the McNary Navigation Lock & Dam.

4.1.2 Each pump(s) shall be a single stage, mixed flow impeller, product-lubricated, wet pit, vertical segmented line-shaft pump. No oil or grease bearings shall be permitted. Each pump is selected to provide the specified flow while operating against the specified total dynamic head at the operating speed and operating conditions specified. The complete pump unit when operating within the specified operating range shall be free of excessive vibration, cavitation, and noise.

4.1.3 To assure unity of responsibility, the pumps and electric motors shall be furnished by the pump manufacturer.

4.1.4 Pump equipment in this section shall be warranted by the pump manufacturer for a period of one year from the date of owner acceptance.

4.1.5 Wrenches, Tools, and Special Equipment.

4.1.5.1 Provide all NONSTANDARD and SPECIAL equipment required for dismantling, reassembly, and general maintenance of the entire pump assembly and motor units. Provide one set of complete lifting attachments such as detachable eyebolts or special slings for handling various parts with a hoist.

4.2 QUALIFICATIONS

4.2.1 Pump Manufacturer shall be certified as an ISO 9001:2015 Quality System Accredited Company.

4.3 DOCUMENTATION

4.3.1 Pre-Award Submittals shall include at least the following:

4.3.1.1 Standard manufacturer’s product literature and/or catalogues of the pumping equipment.

4.3.1.2 Copy of pump manufacturer’s ISO 9001:2015 Certificate.

4.3.1.3 Pumps must be product lubricated with stainless steel impellers and no oil or grease.

4.3.1.4 Factory pump performance curves including rate of flow vs. total head, rate of flow vs.

efficiency, rate of flow vs. input power, and rate of flow vs. NPSHR. Curves shall be based on factory vertical open sump testing per ANSI/HI of an existing and tested pump impeller bowl model.

4.3.1.5 Shop general dimension drawings detailing overall pump dimensions, weights and pump interface details, and listing materials of the supply contract.

4.3.1.6 Electric Motor drawings, description, features, dimension print, nameplate data, performance data, and external wiring (Connection) diagram (including accessory connection diagrams).

4.3.1.7 Pump coating system data including MSDS sheets.

4.3.2 Delivery Submittals

4.3.2.1 Warranty statement and contact information for pump manufacturer and local service representative.

4.3.2.2 Certified Pump Performance Curves from Factory Pump Performance Testing.

4.3.2.3 Operating instructions including a list personnel hazards and product safety precautions for all operating conditions, in addition to procedures for installation, setup, startup, shutdown, normal operation, and emergency operation. Also include a list of Environmental Conditions under which the equipment should not be allowed to run.

4.3.2.4 Recommended preventive maintenance schedule and procedures.

4.3.2.5 Recommended troubleshooting guides and diagnostic techniques.

4.3.2.6 Spare parts lists, for both recommended spare parts and those provided under this contract.

Include a full description, nomenclature, and serial number of each part.

4.4 PUMP REQUIREMENTS

4.4.1 Pump Design Condition: 12,000 GPM @ 40 Ft TDH, 1185 RPM, minimum 87.2% bowl efficiency, maximum 33 Ft. npshr.

4.4.2 Pump Configuration: Vertical, Above Grade Discharge 20” Diameter, 42’-2” pump length bottom of baseplate to the lower sill level. 48’-2” to the bottom of the pump suction chamber.

4.5 PUMP Manufacturing

Vertical line-shaft pump(s) shall be of segmented (jointed) manufacturing. One-piece pumps shall not be accepted. Pumps shall be single stage, mixed flow impeller pump, product-lubricated by water being pumped.

No grease, greased bushings, or oil is allowed. Pumps shall be designed so that no major modification, alterations, or additions will be required to the pump station or suction bays to accommodate it. Pumps shall fit within the dimensions shown on the Project drawings.

4.5.1 The structural integrity of the complete pumping systems shall be the responsibilities of the manufacture.

4.5.2 Impeller: Impeller shall be manufactured of forged stainless steel per ASTM A788, type 316L.

Impeller hub shall be bored and keyed for secure locking to the pump shaft as well as for easy removal. Entire impeller shall be statically and dynamically balanced.

4.5.3 Suction Bell & Impeller Bowl: Suction bell & impeller bow; shall be one integrated segment constructed of type 316L stainless and shall be flanged to the pump bowl. Suction bell shall have a flared inlet designed to reduce entrance losses and shall be able to support the weight of the impeller and pump shaft when dismantling the pump. Shaft bearings in the suction bell shall not be accepted. 29-3/4” (+/-0.5”).

4.5.4 Diffuser Bowl: Diffuser bowl shall be manufactured of stainless-steel type 316L, flanged at both ends allowing ease of assembly/ disassembly. The flanges shall have register fits and be closely machined to ensure shaft and propeller alignments. The use of dowels shall not be accepted.

Diffuser shall contain support for impeller shaft bearings and have vanes to guide the pumped flow. The diffuser blades shall be designed and manufactured to minimize head loss and optimize pump efficiency.

4.5.5 Column Assembly and Discharge Elbow: Pump column and discharge elbow shall be constructed of ASTM A36 structural carbon steel or equivalent. No pump segment shall be greater than 8 feet in length, subject to results of a dynamic analysis. Column flanges shall be machined to allow for the installation and auto-alignment of an intermediate, removable, shaft support spiders.

4.5.6 Flanged Joints: All flanged joints shall be airtight and watertight, without the use of preformed gaskets. Flanges shall be register fit and closely machined to ensure shaft and propeller alignments, and shall have external stiffeners, if needed. Flanges shall be concentric to centerline of the shaft to within 0.002 inch and mating surfaces on flange faces shall be machined to 125 micro-inch finish or better. Dowels shall not be permitted.

4.5.7 Pump Shaft: All Pump shafting shall be constructed of high tensile, pump shaft quality, duplex stainless steel, type S31803. The shaft shall be of sufficient diameter capable of transmitting required horsepower and torque throughout entire operating range of pump and sized to be free of undo vibrations. Shaft design shall be based on criteria set forth in UFGS 354501, Paragraph 2.4.9.1, Shaft for two different design cases. The first case uses a factor-of-safety of 5, based on the ultimate tensile strength of the shaft material, and maximum horsepower based on pump requirements. The second case uses 75 percent of the yield strength of shaft material and maximum motor torque, based on pump operating requirements.

4.5.8 Radial Bearings: Bearings shall be nitrile rubber, water lubricated bushings, lubricated by the water being pumped. Bearings shall be located within the pump diffuser, stuffing box, and intermediate locations as required. Tailcone bearings are not permitted. Grease or oil bearings are not allowed. Intermediate bearings shall be provided as required and shall be supported by removable bearing retainers.

4.5.9 Stuffing Box: Stuffing box and packing gland shall be constructed from carbon steel with 304 stainless steel gland bolts. Packing shall be Teflon impregnated and lantern ring shall be bronze.

4.5.10 Thrust Bearings: Thrust bearings shall be provided in the vertical electric motor and be rated for a minimum B10 life of 50,000 hours at maximum down thrust.

4.5.11 Lifting Lugs: Pump segments shall be furnished with lifting lugs to facilitate pump handling for assembly, installation, removal, and pump maintenance.

4.5.12 Welding: All welds shall be continuous, with full penetration both inside and outside.

4.5.13 Surface Preparation and Coating: All non-stainless-steel components shall have surface preparation to white metal blast cleaning SSPC-SP5 to profile depth of 1.5 mils and coated to 12 mils thickness of high solids, polyamide cured two-part epoxy paint, Jotamastic 90 Al or similar, using an airless spray.

4.6 ELECTRIC MOTOR DRIVER

4.6.1 Each pump shall be driven by a Vertical Hollow Shaft (VHS) motor with the following salient characteristics:

4.6.1.1 200 HP, 1200 RPM 6 Pole, 460V/60Hz/3Ph.

4.6.1.2 Totally Enclosed Fan Cooled (TEFC).

4.6.1.3 Base diameter: Standard and sized by pump manufacturer.

4.6.1.4 Bearings: A spare set shall be included for one motor only.

4.6.1.5 Bearings: All bearings must be self-cooling unless otherwise approved.

4.6.1.6 Bearing Insulation: Both bearings shall be insulated.

4.6.1.7 Enclosure: 841 PLUS® Modifications

4.6.1.7.1 Premium efficiency.

4.6.1.7.2 CORRO-DUTY® TEFC cast-iron material.

4.6.1.7.3 INPRO\SEAL® on shaft extension end.

4.6.1.7.4 1.15 Service Factor.

4.6.1.7.5 Ground lug in conduit box.

4.6.1.7.6 Ground pad on the frame.

4.6.1.7.7 Class F insulation with 80 Deg C rise at 1.0 Service Factor

(Resistance Method).

4.6.1.7.8 Special Balance.

4.6.1.7.9 Special Shaft Run-Out.

4.6.1.7.10 Oversized main Conduit Box.

4.6.1.7.11 NEMA Design B.

4.6.1.7.12 Non-Witnessed IEEE 841 Enhanced No Load Test.

4.6.1.7.13 841 PLUS® MODIFICATIONS nameplate.

4.6.1.7.14 50,000 hr. bearing L-10 Life. Pump manufacturer to supply thrust information to motor manufacturer.

4.6.1.7.15 Special 3-year warranty.

4.6.1.8 Insulation Class:

4.6.1.8.1 Form Wound Coil in accordance with UFGS Section 262901Part 2, Para 2.3.5.c.

4.6.1.8.2 PREMIUM EVERSEAL® (SEALED) application to meet sealed per NEMA MG1-1.27.2 spray test per NEMA MG1-20.18, or immersion test.

4.6.1.9 Nameplates: As per NEMA MG1, the motor nameplates shall contain at a minimum rated voltage, rated full-load, amperes, rated horsepower, service factor, number of phases, RPM at rated load, frequency, code letter, locked-rotor amperes, duty rating, insulation system designation, and maximum ambient design temperature.

4.6.1.10 Nameplates, Special: Rotation arrows shall be installed on both motors.

4.6.1.11 Non-Reverse Ratchet: Non-Reverse Ratchets shall be installed on both motors.

4.6.1.12 Oil Supplied by Pump Manufacturer: Pump manufacturer shall supply sufficient synthetic oil for both motors and one complete oil change for both motors. Synthetic oil viscosity based upon ambient temperatures between 5 Deg F and 77 Deg F. Oil containers shall not exceed a 30-gallon drum due to SPCC limitations.

4.6.1.13 Winding Heaters: Install on each motor. Shall be:

4.6.1.13.1 120v/1ph/60Hz.

4.6.1.13.2 Designed to hold the temperature of the windings to 10 Dec C above ambient.

4.6.1.13.3 Design for continuous operation and uniform dissipation of heat throughout the length of the heater.

4.6.1.13.4 Both shall be routed to the auxiliary conduit box.

4.6.1.13.5 Thermostatically Controlled.

4.6.1.14 Screens and Stainless-Steel Hardware: Stainless-Steel screens with 1/4" mesh shall be installed on both motors. Stainless-Steel hardware shall be installed on both motors.

4.6.1.15 Steady Bushing: Steady Bushings shall be installed on both motors.

4.6.1.16 Thermal Protection for Windings: Winding Thermostats, Normally Closed (N.C.) shall be installed to shut down the unit upon excessive winding temperatures.

4.6.1.17 Vibration Detector: Vibration detector shall be installed in the upper bracket. Seismic switches, electronic solid-state, Piezo-Electric velocity sensitive. Units of Measure – Inches Per Second.

4.6.1.17.1 Alarm and Shutdown

4.6.1.17.2 Indicating Capability.

4.6.1.17.3 Weatherproof Housing.

4.6.1.17.4 Time Delay.

4.6.1.17.5 Remote Reset Capable.

4.6.1.18 Accessory Conduit Box: An oversized accessory Conduit Box shall be installed on each motor. Prewire following items to a terminal strip:

4.6.1.18.1 Thermostatically Controlled winding heater.

4.6.1.18.2 Winding Thermostat N.C. snap action switches.

4.6.1.18.3 Vibration Detector.

4.6.1.19 Factory Testing – Complete Test along with Form Wound Coil Test, and Winding Space Heater Test. Complete test shall include.

4.6.1.19.1 Excitation Test.

4.6.1.19.2 Impedance Test.

4.6.1.19.3 Performance Test.

4.6.1.19.4 Speed-Torque Test.

4.6.1.19.5 Temperature Test.

4.6.1.19.6 Insulation Resistance-Temperature Test.

4.6.1.19.7 Cold and Hot Resistance Measurement.

4.6.1.19.8 Dielectric Test.

4.6.1.19.9 Sound Level Test.

4.6.1.19.10 Vibration Measurement.

4.6.1.19.11 Conformance Tests.

4.6.1.20 Factory Testing – Check Test Only: One motor shall have a check test consisting of the following.

4.6.1.20.1 Routine test in accordance with NEMA MG1 Paragraph 12.55, 20.16.2, and 31.6.2.

4.6.1.20.2 Cold resistance measurement.

4.6.1.20.3 Insulation resistance and winding temperature.

4.6.1.20.4 Conformance Test in accordance with NEMA MG1 paragraph

12.62, 12.63, and 20.18.

4.6.1.20.5 Vibration measurement in accordance with NEMA MG1 Part 7.

4.7 DELIVERY, STORAGE, AND HANDLING OF EQUIPMENT

4.7.1 All equipment and parts must be properly protected against any damage.

4.7.2 Ship each motor in the vertical position with the rotor blocked inside the stator to prevent damage to the bearings. Mount securely to a skid or pallet of ample size. Box all small parts or elements.

Perform the skid mounting and boxing in a manner which will prevent damage or distortion to the motor during loading, shipment, unloading, indoor storage, and subsequent handling.

4.7.3 Ship each motor with a three-way impact recorder to measure magnitude and direction of longitudinal (Y), lateral (X), and vertical (Z) impacts suffered during shipment.

4.7.4 Each pump shall be assembled at the manufacturer's plant to assure proper fitting and alignment of all parts. Factory assembled parts and components shall not be dismantled for shipment. Due to the pump length, each pump shall be delivered in two segments, easily assembled in the field.

4.7.5 The pump shall be identified by means of a separate nameplate, permanently affixed in a conspicuous location. The plate shall bear the manufacturer's name, model designation, serial number, and other pertinent information such as design capacity, design speed, etc. The plate shall be made of corrosion-resisting metal with raised or depressed lettering and contrasting background.

4.7.6 Safety guards and/or covers shall be provided wherever necessary to protect the operators from accidental contact with moving parts. Guards and covers shall be of sheet steel, expanded metal, or another acceptable material and removable for disassembly of the pump.

4.8 TESTING

4.8.1 Factory Pump Performance Testing: Unwitnessed Factory pump performance testing shall be performed at the manufacturer’s site prior to pump shipment. Testing must be Open Sump Vertical Pump Testing and in accordance with testing standards ANSI/HI 14.6-2016 and ANSI/ASME PTC 18.1. Testing shall be performed either using an approved model or the first pump produced. Closed loop or closed suction test configurations shall not be accepted. If published NPSHr curves are not available, NPSH testing must also be performed per ANSI/HI 14.6-2016.

4.8.2 Whenever possible a minimum of seven test points shall be tested and recorded including one above and below the specified operating range of the pump. Head measurements shall be taken using a multiple tap with a loop manifold configuration. A thorough Pump Performance Test Plan must be supplied for approval before testing, detailing the test configuration and testing procedure, verifying adherence to specifications. Certified Pump Performance Curves shall be generated showing pump capacity vs. total head, and pump capacity vs. pump bowl efficiency, stamped by a Registered Professional Engineer.

5.0 COMMERCIAL PACKAGING AND SHIPMENT REQUIREMENTS

5.1 ASTM-A700-14 – Standard Guide of Packaging, Marking, and Loading Methods for Steel Products for Shipment pertain to Piping, Round Bar, Flat Bar, and Channel Strut.

5.2 ASTM-D3951-18 – Standard Practice for Commercial Packing applies to all other items except for the dewatering and unwatering pumps.

6.0 DELIVERY REQUIREMENTS

6.1 Materials identified herein shall be delivered FOB Destination no later than Fifty (50) weeks after final approval of submittal packages.

6.2 Shipments are only allowed during normal business hours of Monday – Thursday 7:00am to 4:00pm. No shipments shall be made accepted on Federal Holidays. All shipments shall be delivered to:

McNary Lock and Dam 82790 Devore Rd.

Umatilla, OR 97882

7.0 SECURITY REQUIREMENTS

7.1 General Security Requirements and Guidance. The security requirements described below apply to all contract personnel (including employees of the prime Contractor (“Contractor”) and all subcontractor employees) supporting the performance requirements of the contract. The Contractor is responsible for compliance with these security requirements. Questions regarding security matters shall be addressed to the designated Government representative. Contract personnel are critical to the overall security and safety of US Army Corps of Engineers (USACE) installations, facilities and activities and security awareness training contributes to those efforts. The Department of Defense (DoD) and Army security training requirements specified below, if applicable, are performance requirements, all applicable contract personnel shall complete initial training within 30 days of contract award or the date new contract personnel begin performance on the contract. Within five business days from the completion of training, the Contractor shall provide written documentation (e.g. email or memorandum) to the Government representative. The documentation shall include the names of the contract personnel trained and which training they completed; the Contractor shall maintain training records as part of their contract files and be prepared to provide copies of training certificates to the Government representative. Contractor personnel and vehicles are subject to search when entering federal installations. Additionally, all contract personnel shall comply with Force Protection Condition (FPCON) measures, Random Antiterrorism measures (commonly referred to as “RAMs”), and Health Protection Condition (HPCON) measures. The Contractor is responsible for meeting performance requirements during elevated FPCON and/or HPCON levels in accordance with applicable RA plans and procedures – this includes identifying mission essential and non-mission essential personnel. In addition to the changes otherwise authorized by the changes clause of the contract, should the FPCON and/or HPCON levels at any individual facility or installation change, the Government may implement security changes that affect contract personnel. The Contractor shall ensure all contract personnel are aware of their security responsibilities, including any site-specific requirements identified in the local policies or procedures.

7.2 Physical Security and Access Control Requirements. All contract personnel requiring physical access to a federal installation or facility shall comply with the access control procedures of that location. Contract personnel requiring unescorted access to meet contract performance requirements on a DoD installation in the US shall be vetted by the installation/facility Provost Marshall/Directorate of Emergency Services/Security Office using the National Crime Information Center-Interstate Identification Index (commonly referred to “NCIC-III”) and Terrorist Screening Database (commonly referred to as “TSDB”). Contract personnel shall comply with all personal identity verification requirements specified in installation/facility policies and procedures. Contract personnel who do not meet requirements for unescorted access to USACE facilities shall coordinate escorted access with the Government representative, as needed. Contract personnel who receive keys, access cards, or lock combinations that provide access to government-owned property shall comply with key and lock control procedures of the RA.

ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

0001 2 Each Vertical Mixed Flow Impeller Lineshaft

FFP

Pump for Chamber Dewatering, Portable. See item 3.1. IAW Technical Specifications.

NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD unique identification or a DoD recognized unique identification equivalent.

FOB: Destination

PSC CD: 4320

NET AMT

ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

0002 1 Set Chamber Dewatering Pump and Motor

FFP

Spare Parts, Kit. See item 3.2. IAW Technical Specifications.

FOB: Destination

PSC CD: 4320

NET AMT

CLAUSES INCORPORATED BY REFERENCE

52.203-3 Gratuities APR 1984 52.203-11 Certification And Disclosure Regarding Payments To

Influence Certain Federal Transactions

SEP 2007

52.203-12 Limitation On Payments To Influence Certain Federal Transactions

JUN 2020

52.203-16 Preventing Personal Conflicts of Interest JUN 2020

52.203-17 Contractor Employee Whistleblower Rights and Requirement To Inform Employees of Whistleblower Rights

JUN 2020

52.203-18 Prohibition on Contracting With Entities That Require Certain Internal Confidentiality Agreements or Statements-- Representation

JAN 2017

52.204-4 Printed or Copied Double-Sided on Postconsumer Fiber Content Paper

MAY 2011

52.204-7 System for Award Management OCT 2018 52.204-13 System for Award Management Maintenance OCT 2018 52.204-16 Commercial and Government Entity Code Reporting AUG 2020 52.204-18 Commercial and Government Entity Code Maintenance AUG 2020 52.204-21 Basic Safeguarding of Covered Contractor Information

Systems

NOV 2021

52.204-22 Alternative Line Item Proposal JAN 2017 52.204-24 Representation Regarding Certain Telecommunications and

Video Surveillance Services or Equipment

NOV 2021

52.212-1 Instructions to Offerors--Commercial Products and Commercial Services

MAR 2023

52.212-4 Contract Terms and Conditions--Commercial Products and Commercial Services

DEC 2022

52.232-40 Providing Accelerated Payments to Small Business Subcontractors

MAR 2023

52.242-13 Bankruptcy JUL 1995 52.243-1 Changes--Fixed Price AUG 1987 52.247-34 F.O.B. Destination NOV 1991 52.253-1 Computer Generated Forms JAN 1991 252.203-7000 Requirements Relating to Compensation of Former DoD

Officials

SEP 2011

252.203-7002 Requirement to Inform Employees of Whistleblower Rights DEC 2022 252.203-7003 Agency Office of the Inspector General AUG 2019 252.203-7005 Representation Relating to Compensation of Former DoD

Officials

SEP 2022

252.204-7003 Control Of Government Personnel Work Product APR 1992 252.204-7008 Compliance With Safeguarding Covered Defense Information

Controls

OCT 2016

252.204-7012 Safeguarding Covered Defense Information and Cyber Incident Reporting

JAN 2023

252.204-7015 Notice of Authorized Disclosure of Information for Litigation Support

JAN 2023

252.204-7016 Covered Defense Telecommunications Equipment or Services -- Representation

DEC 2019

252.204-7017 Prohibition on the Acquisition of Covered Defense Telecommunications Equipment or Services -- Representation

MAY 2021

252.204-7018 Prohibition on the Acquisition of Covered Defense Telecommunications Equipment or Services

JAN 2023

252.204-7019 Notice of NIST SP 800-171 DoD Assessment Requirements MAR 2022 252.204-7020 NIST SP 800-171 DoD Assessment Requirements JAN 2023 252.209-7004 Subcontracting With Firms That Are Owned or Controlled By

The Government of a Country that is a State Sponsor of Terrorism

MAY 2019

252.223-7008 Prohibition of Hexavalent Chromium JAN 2023 252.225-7001 Buy American And Balance Of Payments Program--Basic JAN 2023 252.225-7002 Qualifying Country Sources As Subcontractors MAR 2022 252.225-7013 Duty-Free Entry--Basic DEC 2022 252.225-7048 Export-Controlled Items JUN 2013

252.232-7010 Levies on Contract Payments DEC 2006 252.243-7002 Requests for Equitable Adjustment DEC 2022 252.247-7023 Transportation of Supplies by Sea JAN 2023

CLAUSES INCORPORATED BY FULL TEXT

52.204-26 COVERED TELECOMMUNICATIONS EQUIPMENT OR SERVICES--REPRESENTATION (OCT

2020)

(a) Definitions. As used in this provision, “covered telecommunications equipment or services” and "reasonable inquiry" have the meaning provided in the clause 52.204-25, Prohibition on Contracting for Certain Telecommunications and Video Surveillance Services or Equipment.

(b) Procedures. The Offeror shall review the list of excluded parties in the System for Award Management (SAM) (https://www.sam.gov) for entities excluded from receiving federal awards for “covered telecommunications equipment or services”.

(c) Representations.

(1) The Offeror represents that it [ ___ ] does, [ ___ ] does not provide covered telecommunications equipment or services as a part of its offered products or services to the Government in the performance of any contract, subcontract, or other contractual instrument.

(2) After conducting a reasonable inquiry for purposes of this representation, the offeror represents that it [ ___ ] does, [ ___ ] does not use covered telecommunications equipment or services, or any equipment, system, or service that uses covered telecommunications equipment or services.

(End of provision)

52.209-2 PROHIBITION ON CONTRACTING WITH INVERTED DOMESTIC CORPORATIONS--

REPRESENTATION (NOV 2015)

(a) Definitions. Inverted domestic corporation and subsidiary have the meaning given in the clause of this contract entitled Prohibition on Contracting with Inverted Domestic Corporations (52.209-10).

(b) Government agencies are not permitted to use appropriated (or otherwise made available) funds for contracts with either an inverted domestic corporation, or a subsidiary of an inverted domestic corporation, unless the exception at 9.108-2(b) applies or the requirement is waived in accordance with the procedures at 9.108-4.

(c) Representation. The Offeror represents that--

(1) It [ ___ ] is, [ ___ ] is not an inverted domestic corporation; and

(2) It [ ___ ] is, [ ___ ] is not a subsidiary of an inverted domestic corporation.

52.209-11 REPRESENTATION BY CORPORATIONS REGARDING DELINQUENT TAX LIABILITY OR A

FELONY CONVICTION UNDER ANY FEDERAL LAW (FEB 2016)

(a) As required by sections 744 and 745 of Division E of the Consolidated and Further Continuing Appropriations Act, 2015 (Pub. L. 113-235), and similar provisions, if contained in subsequent appropriations acts, the Government will not enter into a contract with any corporation that--

(1) Has any unpaid Federal tax liability that has been assessed, for which all judicial and administrative remedies have been exhausted or have lapsed, and that is not being paid in a timely manner pursuant to an agreement with the authority responsible for collecting the tax liability, where the awarding agency is aware of the unpaid tax liability, unless an agency has considered suspension or debarment of the corporation and made a determination that suspension or debarment is not necessary to protect the interests of the Government; or

(2) Was convicted of a felony criminal violation under any Federal law within the preceding 24 months, where the awarding agency is aware of the conviction, unless an agency has considered suspension or debarment of the corporation and made a determination that this action is not necessary to protect the interests of the Government.

(b) The Offeror represents that--

(1) It is [ ] is not [ ] a corporation that has any unpaid Federal tax liability that has been assessed, for which all judicial and administrative remedies have been exhausted or have lapsed, and that is not being paid in a timely manner pursuant to an agreement with the authority responsible for collecting the tax liability; and

(2) It is [ ] is not [ ] a corporation that was convicted of a felony criminal violation under a Federal law within the preceding 24 months.

52.212-3 OFFEROR REPRESENTATIONS AND CERTIFICATIONS--COMMERCIAL PRODUCTS AND

COMMERCIAL SERVICES (DEC 2022) ALTERNATE I (OCT 2014)

The Offeror shall complete only paragraph (b) of this provision if the Offeror has completed the annual representations and certification electronically in the System for Award Management (SAM) accessed through https://www.sam.gov. If the Offeror has not completed the annual representations and certifications electronically, the Offeror shall complete only paragraphs (c) through (v) of this provision.

(a) Definitions. As used in this provision --

"Covered telecommunications equipment or services" has the meaning provided in the clause 52.204-25, Prohibition on Contracting for Certain Telecommunications and Video Surveillance Services or Equipment.

"Economically disadvantaged women-owned small business (EDWOSB) concern" means a small business concern that is at least 51 percent directly and unconditionally owned by, and the management and daily business operations of which are controlled by, one or more women who are citizens of the United States and who are economically disadvantaged in accordance with 13 CFR part 127, and the concern is certified by SBA or an approved third-party certifier in accordance with 13 CFR 127.300. It automatically qualifies as a women-owned small business eligible under the WOSB Program.

"Forced or indentured child labor" means all work or service-

(1) Exacted from any person under the age of 18 under the menace of any penalty for its nonperformance and for which the worker does not offer himself voluntarily; or

(2) Performed by any person under the age of 18 pursuant to a contract the enforcement of which can be accomplished by process or penalties.

"Highest-level owner" means the entity that owns or controls an immediate owner of the offeror, or that owns or controls one or more entities that control an immediate owner of the offeror. No entity owns or exercises control of the highest level owner.

"Immediate owner" means an entity, other than the offeror, that has direct control of the offeror. Indicators of control include, but are not limited to, one or more of the following: Ownership or interlocking management, identity of interests among family members, shared facilities and equipment, and the common use of employees.

"Inverted domestic corporation" means a foreign incorporated entity that meets the definition of an inverted domestic corporation under 6 U.S.C. 395(b), applied in accordance with the rules and definitions of 6 U.S.C. 395(c).

"Manufactured end product" means any end product in product and service codes (PSCs) 1000-9999, except--

(1) PSC 5510, Lumber and Related Basic Wood Materials;

(2) Product or Service Group (PSG) 87, Agricultural Supplies;

(3) PSG 88, Live Animals;

(4) PSG 89, Subsistence;

(5) PSC 9410, Crude Grades of Plant Materials;

(6) PSC 9430, Miscellaneous Crude Animal Products, Inedible;

(7) PSC 9440, Miscellaneous Crude Agricultural and Forestry Products;

(8) PSC 9610, Ores;

(9) PSC 9620, Minerals, Natural and Synthetic; and

(10) PSC 9630, Additive Metal Materials.

"Place of manufacture" means the place where an end product is assembled out of components, or otherwise made or processed from raw materials into the finished product that is to be provided to the Government. If a product is disassembled and reassembled, the place of reassembly is not the place of manufacture.

"Predecessor" means an entity that is replaced by a successor and includes any predecessors of the predecessor.

"Reasonable inquiry" has the meaning provided in the clause 52.204-25, Prohibition on Contracting for Certain Telecommunications and Video Surveillance Services or Equipment.

"Restricted business operations" means business operations in Sudan that include power production activities, mineral extraction activities, oil-related activities, or the production of military equipment, as those terms are defined in the Sudan Accountability and Divestment Act of 2007 (Pub. L. 110-174). Restricted business operations do not include business operations that the person (as that term is defined in Section 2 of the Sudan Accountability and Divestment Act of 2007) conducting the business can demonstrate--

(1) Are conducted under contract directly and exclusively with the regional government of southern Sudan;

(2) Are conducted pursuant to specific authorization from the Office of Foreign Assets Control in the Department of the Treasury, or are expressly exempted under Federal law from the requirement to be conducted under such authorization;

(3) Consist of providing goods or services to marginalized populations of Sudan;

(4) Consist of providing goods or services to an internationally recognized peacekeeping force or humanitarian organization;

(5) Consist of providing goods or services that are used only to promote health or education; or

(6) Have been voluntarily suspended.

"Sensitive technology"--

(1) Means hardware, software, telecommunications equipment, or any other technology that is to be used specifically--

(i) To restrict the free flow of unbiased information in Iran; or

(ii) To disrupt, monitor, or otherwise restrict speech of the people of Iran; and

(2) Does not include information or informational materials the export of which the President does not have the authority to regulate or prohibit pursuant to section 203(b)(3) of the International Emergency Economic Powers Act (50 U.S.C. 1702(b)(3)).

"Service-disabled veteran-owned small business concern"--

(1) Means a small business concern--

(i) Not less than 51 percent of which is owned by one or more service-disabled veterans or, in the case of any publicly owned business, not less than 51 percent of the stock of which is owned by one or more service-disabled veterans; and

(ii) The management and daily business operations of which are controlled by one or more service-disabled veterans or, in the case of a service-disabled veteran with permanent and severe disability, the spouse or permanent caregiver of such veteran.

(2) Service-disabled veteran means a veteran, as defined in 38 U.S.C. 101(2), with a disability that is service-connected, as defined in 38 U.S.C. 101(16).

"Small business concern"--

(1) Means a concern, including its affiliates, that is independently owned and operated, not dominant in its field of operation, and qualified as a small business under the criteria in 13 CFR part 121 and size standards in this solicitation.

(2) Affiliates, as used in this definition, means business concerns, one of whom directly or indirectly controls or has the power to control the others, or a third party or parties control or have the power to control the others. In determining whether affiliation exists, consideration is given to all appropriate factors including common ownership, common management, and contractual relationships. SBA determines affiliation based on the factors set forth at 13

CFR 121.103.

"Small disadvantaged business concern, consistent with 13 CFR 124.1002", means a small business concern under the size standard applicable to the acquisition, that--

(1) Is at least 51 percent unconditionally and directly owned (as defined at 13 CFR 124.105) by--

(i) One or more socially disadvantaged (as defined at 13 CFR 124.103) and economically disadvantaged (as defined at 13 CFR 124.104) individuals who are citizens of the United States; and

(ii) Each individual claiming economic disadvantage has a net worth not exceeding $750,000 after taking into account the applicable exclusions set forth at 13 CFR 124.104(c)(2); and

(2) The management and daily business operations of which are controlled (as defined at 13 CFR 124.106) by individuals, who meet the criteria in paragraphs (1)(i) and (ii) of this definition.

"Subsidiary" means an entity in which more than 50 percent of the entity is owned--

(1) Directly by a parent corporation; or

(2) Through another subsidiary of a parent corporation.

"Successor" means an entity that has replaced a predecessor by acquiring the assets and carrying out the affairs of the predecessor under a new name (often through acquisition or merger). The term "successor" does not include new offices/divisions of the same company or a company that only changes its name. The extent of the responsibility of the successor for the liabilities of the predecessor may vary, depending on State law and specific circumstances.

"Veteran-owned small business concern" means a small business concern--

(1) Not less than 51 percent of which is owned by one or more veterans (as defined at 38 U.S.C.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .