About this file
This document is a product specification sheet for the Automatic Wire Test Set (AWTS) 100000-02, a portable diagnostic system designed for comprehensive wire and component analysis in military and aerospace environments. The AWTS-02 is a DOD-approved test set capable of performing advanced electrical measurements, including voltage, current, resistance, and capacitance testing across a wide range of parameters. Key specifications include 1,152 test points with 256 random access points, expandability to over 15,000 test points, and the ability to handle embedded components like relays and data buses.
The system meets rigorous military standards (MIL-STD-810G, MIL-STD-461F, MIL-PRF-28800F) and supports operation in extreme conditions, with a temperature range of 14-131°F, 0-100% relative humidity, and resistance to salt exposure, vibration, and dust. Its measurement capabilities span 0.25 to 500 VDC, 0.005 to 1.0 Amps, and 0 to 1000M Ohms, with specialized functions for diode and voltage measurements. Powered by 115/230 VAC, the system consists of multiple units with dimensions ranging from 9"H x 24.5"L x 19.5"W to 14"H x 27.5"D x 14.5"W, designed for portability and use across various maintenance levels and platforms.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A W T S -0
Accurate Wiring and Component Analysis Anytime, Anywhere!
‚ Portable Environmentally Sealed Packaging
‚ MIL-STD-810G, MIL-STD-461F,
MIL-PRF-28800F Qualified
‚ Fully Programmable Measurement System up to 500 VDC
‚ 1152 Test Points with 256 Random Access (RAX) Points in Base Configuration
‚ Expandable to over 15,000 Test Points
‚ Embedded Wire Mapping and Self Learn Capability for Circuits
Automatic Wire Test Set (AWTS) analyzers are DOD approved common support test sets for use at all levels of maintenance on all platforms.
From established depots to remote deployments, this flexibility enables maintainers to choose where best to perform service and repair actions.
The AWTS -02 configuration (P/N: 100000-02) is focused on supporting harness and wire system maintenance by maximizing the available test points and minimizing system size.
Combined with RAX Energization, systems that include embedded components (relays, data buss, indicators, etc.) can be tackled with ease.
Instructions listed in NAVAIR 17-15W-1, USAF T.O. 33D7-28-34-1.
*Mobile Cart Sold Separately
SYSTEM SPECIFICATIONS
AWTS, P/N: 100000-02
FEATURES
Measurement System
Switching/Energization System
Test Address Points RAX Energization Points Voltage Energization
256 (4 Buses) 0-40 VDC @ 3 A (2 channels)
Operating Conditions
Physical Characteristics
Input Power Physical Dimensions (TCU) Physical Dimensions (SM) Physical Dimensions (CPU w/Case)
115 / 230 VAC (auto-ranging), 50-400 Hz 14"H x 27.5"D x 14.5"W, @ 58 lbs.
14"H x 27.5"D x 14.5"W, @ 61 lbs.
9"H x 24.5"L x 19.5"W, @ 29 lbs.
Voltage Measurement Stimulus Current Measurement Stimulus Resistance Measurement
VI Measurement
DC HIPOT Measurement DC Voltage Measurement AC Voltage Measurement Capacitance Measurement
0.25 to 500 VDC (-0.25 to -500 VDC)
0.005 to 1.0 Amps (-0.005 to -1 Amps) 0 to 1000M Ohms Diode Forward Voltage: 0-25 VDC Diode Leakage: 0-15 mA Current Drain: 0-25 VDC Zener Diode: 0-500 VDC 0.5mA to 2.5mA (100 to 500 VDC) -200 to 200 VDC (up to 500 VDC non switching)
0.0 to 225 VAC (up to 350 VAC non-switching) 0 to 100 µF (extended ranges available)
Relative Humidity - 0-100% *per MIL-PRF-28800F, Class 2
Operating Temperature - 14°-131° F *per MIL-PRF-28800F, Class 2
Functional Shock - 30G *per MIL-PRF-28800F, Class 2
Salt Exposure *per MIL-PRF-28800F, Class 2
Vibration Tested *per MIL-PRF-28800F, Class 2
Loose Cargo Bounce *per MIL-PRF-28800F, Class 2
Explosive Atmosphere *per MIL-PRF-28800F, Class 1
Dust Resistance *per MIL-PRF-28800F, Class 1