This document describes a state and local contract opportunity for a Vulcan C24DA10 series direct steam convection steamer on a cabinet base with a 10 pan capacity and basic controls. The item is to be shipped to the Southwestern Virginia Mental Health Institute in Virginia, and payment will be made by check upon receipt and inspection of the item. The contract opportunity involves the jurisdiction of Smyth County, Virginia.

The document provides detailed technical specifications for the steamer, including its dimensions, capacities, features, connections, and warranty information. It also includes instructions for proper water quality and service connections required for the equipment. The contract opportunity requires the vendor to supply the specified steamer model per the provided details.

Text of this file

Project _________________________________________________________________________

AIA # __________________________________ SIS # __________________________________

Item # _________________________________ Quantity ___________ C.S.I. Section 114000

Approved by_______________________________________ Date___________ Approved by_________________________________________ Date______________

Printed in U.S.A. Vulcan • 2006 Northwestern Pkwy, Louisville, KY 40203 • Phone: 800-814-2028 • Fax: 800-444-0602 • www.vulcanequipment.com F37508 (07-21)

C24DA SERIES

Direct Steam Convection Steamer on Cabinet Base

C24D

A SERIES – D

irect Steam Convection Steam er on Cabinet Base

ANSI/NSF Standard #4

SPECIFIER STATEMENT

Two compartment direct potable steam convection steamer on cabinet base. Stainless steel exterior. Two stainless steel cooking compart ments with coved inte-rior corners. Separate 60 minute timer with constant steam feature for each com partment. Heavy duty doors and door latch mechanisms. Stainless steel water resis-tant cabinet base. 6" adjustable stainless steel legs with flanged feet. 3⁄4" NPT direct potable steam connection and pressure regulator. Requires 120/60/1 power sup-ply, 2.0 amps maximum draw, with 6 foot power cord and 3 prong plug. Single 3⁄4" hose bib water line connec-tion for untreated water. 11⁄2" NPT drain connection.

Exterior Dimensions:

6 pan: 24"w x 35.4"d x 59"h on 6" legs

10 pan: 24"w x 35.4"d x 72"h on 6" legs

UL Listed. Classified by UL to NSF Standard #4.

MODELS

❑ C24DA6 6 pan capacity, basic controls

❑ C24DA10 10 pan capacity, basic controls

STANDARD FEATURES

• Stainless steel exterior

• Two stainless steel cooking compartments with coved interior corners

• Separate 60 minute timer with constant steam feature for each compartment

• Heavy duty doors and door latch mechanisms

• Stainless steel water resistant cabinet base

• 6" adjustable stainless steel legs with flanged feet

• 3⁄4" NPT direct potable steam connection and pressure regulator

• Requires 120/60/1 power supply, 2.0 amps maximum draw.

• Single 3⁄4" hose bib water line connection for untreated water

• 11⁄2" NPT drain connection

• One year limited parts and labor warranty

OPTIONS

❑ Second year extended limited parts and labor warranty contract

❑ Steamer Security Package, includes controls protected by lockable cover, perforated flue cover, security fasteners & tack-welds

ACCESSORIES (PACKAGED AND SOLD SEPARATELY)

❑ Stainless steel pan cover, Qty._______

❑ Removable sliding shelf ,Qty._______

Model C24DA10

F37508 (07-21) Vulcan • 2006 Northwestern Pkwy, Louisville, KY 40203 • Phone: 800-814-2028 • Fax: 800-444-0602 • www.vulcanequipment.com Printed in U.S.A.

C24DA SERIES

Direct Steam Convection Steamer on Cabinet Base

As continued product improvement is a policy of Vulcan, specifications are subject to change without notice.

CAD and/or Revit Files Available

SERVICE CONNECTIONS

ELECTRICAL CONNECTIONS: Unless otherwise specified, Field

Wire Electrical Connection to be 120/60/1 with grounding wire.

Maximum amps 2.0.

DRAIN: Condenser box and compartment, 11⁄2" NPT. (Provide an open air gap type drain within 72" of condenser box and for best results at a distance so steam vapors will not enter the steamer from underneath the control area. Do not connect solidly to any drain connection.)

POTABLE STEAM CONNECTION: 3⁄4" NPT. Supply line 80 lbs./hr.

required at 10-50 PSI (69-345 kPa).

CONDENSING WATER SUPPLY: 3⁄4" hose bib fitting at 20-60 psi.

(138-414 kPa).

WATER QUALITY STATEMENT

The fact that a water supply is potable is no guarantee that it is suitable for steam generation. Your water supply must be within these general guidelines:

SUPPLY PRESSURE 20 - 60 psig HARDNESS* less than 3 grains SILICA less than 13 ppm TOTAL CHLORIDE less than 4.0 ppm pH RANGE 7-8 UN-DISSOLVED SOLIDS less than 5 microns

* 17.1 ppm = 1 grain of hardness

Other factors affecting steam generation are iron content, amount of chloridation and dissolved gases. Water supplies vary from state to state and from locations within a state. Therefore it is necessary that the local water treatment specialist be consulted before the installation of any steam generating equipment.

NOTES

• Dimensions which locate the above connections have a tolerance of

+ or - 3" (+ or - 75mm). Normal dimensions are in inches. Dimensions in [ ] are in millimeters.

• Installation of backflow preventer's, vacuum breakers and other specific code requirements is the responsibility of the owner and installer. It is the responsibility of the owner and installer to comply with local codes.

• Do not use plastic or PVC drains.

• This appliance is manufactured for commercial installation only and is not intended for home use.

Compartment Pan Capacity

Model 1" 21⁄2" 4" 6"

C24DA6 6 3 2 1

C24DA10 10 5 3 2

24.0

[610]

35.5

[901]

23.7

[601]

DRAIN

1.9

[48]

DRAIN

6.0

[152]

28.0

[712]

3.3

[83]

18.3

[464]

LOCATION FOR

STEAM LINE

22.0

[559]

UNTREATED

WATER

25.0

[635]

ELEC

CONNECTION

58.7

[1490]

71.5

[1823]

6 PAN

10 PAN

55.0

[1397]

67.9

[1730]

6 PAN

10 PAN

Other files