Attch1_Salient Characterisitics_91 MSOS Shoot Houses.docx
DOCX document 17 KB Posted
- Attached to
- Modular Shoot House Facilities
- Solicitation number
- F3CTSG4178AW01
About this file
This document contains the Salient Characteristics for the 91st MSOS Modular Shoot House Training Facilities, which is required for a federal contract opportunity. The key details are:
The 91st Missile Security Operations Squadron has a requirement for two (2) 2,400 sq ft Modular Shoot House facilities for close quarters combat (CQC) and active shooter training. The Salient Characteristics specify that the Modular Shoot House must be portable, lightweight, and easily set up/broken down by 2-3 personnel. It must have modular, rearrangeable panel walls, with each panel not exceeding 90 lbs. The panels must be constructed of minimum 15/32" thick CDX or equivalent material able to withstand impact from multiple simulated rounds. The facilities must include a minimum of 5 rooms with corner and center-fed entrances, 15 pre-hung wood doors, and window panels. The facilities must accommodate flip up or pop out targets. Crating and packaging is to be included in the total price.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
91st MSOS Modular Shoot House Training Facilities
SALIENT CHARACTERISTICS
91st MSOS has a requirement for close quarters combat (CQB) and active shooter training that requires the facility that includes the following items:
Modular Training house Panel Kit. Pre-made panel walls, doors, and windows. Includes
(2) 2,400 sq ft Shoot House, all panels painted with primer and exterior latex. No Factory Install (Self Install w/instructions provided).
| DESCRIPTION |
| QUANTITY |
| Modular Shoot House: 2,400 sq/ft |
| 2 |
Details of this requirement include:
· Portable, lightweight easy set-up/break-down (2-3 personnel max)
· Rearrangeable panel walls/layout configuration
· Panels not more than 90 lbs. each
· 88- 86” tall x 2.5″ thick x 4′, 3′, 2′, or 1′ width wall panel options.
· Must be constructed from a minimum of 15/32” thick CDX or equivalent fascia able to withstand impact from multiple sim rounds without passing through material.
· Outdoor rated weather resistant latex paint with a primer base coat.
· Facilities must have minimum of 5 rooms with corner and center fed room entrances.
· 15 pre-hung standard wood doors w/knobs to simulate real life environment for CQB operations.
· Facilities must have window panels. minimum 2.5’ wide x 3.5’ high and a maximum of 3′ wide x 4′ high window opening and a minimum wall relief of 6″or more away from the top, right, and left sides of the panel. With blank opening or optional cutout cover (two total).
· Heavy duty 12-gauge steel panel connector brackets that are powder coated.
· Can accommodate flip up or pop out targets.
· Crating and packaging included in total price.
File details come from the government source that posted it. Updated .