This document is an Attachment B - Draft Performance Elements outlining inspection and travel services for the U.S. Army Corps of Engineers (USACE). The performance elements are divided into three main categories: general inspection items, location-specific travel for St. Polten, Austria, and Sorel-Tracy, Canada. Inspection services include 4-hour and 8-hour periods for witnessing dimensional and non-destructive evaluation (NDE) inspections, which may involve penetrant testing (PT), ultrasonic testing (UT), and magnetic testing (MT). Additional line items cover a 1-hour coordination call with USACE and report preparation, with inspectors required to submit a detailed report including inspection summaries and supporting photographs. The document notes that this is a draft approach and solicits feedback through a Sources Sought submission, with the possibility of additional items being included in the final solicitation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attch A_Anticipated Locations.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment B – Draft Performance Elements
One idea for how to break up line items related to the scope of work is included below. If more than 8 hours is required, the quantity of either the 4 or 8-Hour inspection periods would be issued. May have additional items included at time of solicitation. Note, a solicitation has not yet been prepared. If there are comments on this approach, please provide them in your Sources Sought submission.
Items 100-103: General Items 100 4-Hour Inspection 4-hours of labor associated with witnessing dimensional and/or NDE inspections. NDE inspections may include PT, UT, and MT.
101 8-Hour Inspection 8-hours of labor associated with witnessing dimensional and/or NDE inspections. NDE inspections may include PT, UT, and MT.
102 1-Hour Coordination Call Inspector participates in a 1-hour coordination call with USACE. This could be either for the pre-inspection coordination call or the post-report coordination call.
103 Prepare and Submit Report Prepare and submit a report that includes a summary of what inspections were witnessed and the results. Include photos within the report to support the summary.
Items 104: Items specific to St. Polten, Austria 104 Travel to/from St. Polten, Austria Assumed cost associated with an inspector traveling to and from St. Polten, Austria to support an inspection.
Items 105: Inspection specific to Sorel-Tracy, Canada 105 Travel to/from Sorel-Tracy, Canada Assumed cost associated with an inspector traveling to and from Sorel-Tracy, Canada to support an inspection.