ATTCH 06 DETAILED DRAWINGS.pdf
PDF 3 MB Posted
- Attached to
- Repair Airfield Electrical Systems Amendment
- Solicitation number
- FA3300-26-R-0016-0001
About this file
This document is a set of technical drawings and plans for airfield lighting infrastructure work at the north end of a runway, specifically addressing fixture layout, approach lighting, and electrical distribution systems.
The drawings depict the North End Threshold/Approach Fixture Layout, North End Approach Fixtures and Notes, North End Approach Fixture Layout, and North End Windcone Plan with detailed electrical schematics. The plans identify affected circuits including S-1, PP-2, A-1, A-2, and A-3, with primary focus on ductbank replacement and conductor work. Key notes specify that ductbanks containing only affected circuits are to be replaced in their entirety, while ductbanks containing additional circuits will not be replaced. The contractor is explicitly instructed not to remove or impair circuits not included in the affected circuits list. Circuit WC-1, installed in existing conduit ductbank from the airfield lighting vault to the windcone, is designated as the last non-affected circuit; damaged affected circuits between this point and the vault require conductor replacement only. The plans utilize standard legend symbols distinguishing blank crossed base, un-directional fixture, and directional fixture installations. Multiple taxiway and approach lighting positions are marked with specific circuit identifications, and coordination notes address equipment locations and clearance requirements for proper fixture spacing and electrical distribution routing.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment FA330026R00160001 SF 30.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
. 1 b.�/ / T1-o> \l9.
CKT. A-1
___, CKT. A-2
CKT. A-3
CKT. S-1
T1-47 --------
\01 1213 \jE) fCKT. T1
__ ___ 11;26 __________ 11:).,5 ____ } ____ ��
T1-4� �-- __.�
3 ° __ - T1-65 ----
/ /4::::}S:.;;:�; lHg
1\-62 -------$-----------r�,.---- -1-51 \ ---
T AXI'w AY A �--=-------
'.) ':f:1� 11-61 ------ ----- 11-63
CKT. T1
__ ,,...,,..,,. 'f'� \�
T1 -52 " , � \ "' Q� �
_ . .,,. CKT. D-1
� \(µ, _., CKT. R-1, /2 R-2 & T-1 � \ v
Jtl!J \
' \ v �\ I CKT. A-1
0.D�
I � \
CKT. A-20
CKT. A-3
CKT. S-1
'd, CKT. R-1
CKT. R-2
CKT. D-1
;p � �
' v
'd, CKT.
D-1 (
JI..
CKT. PP-2
\ WIND CONE/
R-1 R-2
PP-2
D-1
CKT. WC-1@
CKT. A-1
CKT. A-2
CKT. A-3
CKT. S-1
CKT. PP-2
CKT. WC-1@
CKT. D-1
t0 � 6
KT. R
� R
�� '\ \ 'd, 'd, \ 0-
�h. \
NOTES
�Jf:'&�� E-11
KEY PLAN
NOT TO SCALE
1. AFFECTED CIRCUITS INCLUDE S-1, PP-2, A-1, A-2, A-3
in i ,.._ C
II �
• I � w
2. DUCTBANKS CONTAINING ONLY AFFECTED CIRCUITS TO BE REPLACED. DUCTBANKS
CONTAINING ADDITIONAL CIRCUITS WILL NOT BE REPLACED.
KEYED NOTES
(D DUCKBANK ONLY CONTAINS AFFECTED CIRCUITS FROM THIS POINT
AND NORTHWARD. REPLACE DUCTBANK/CONDUCTORS OF AFFECTED
CIRCUITS BETWEEN THIS POINT AND THE FIXTURES.
@ CKT WC-1 CIRCUIT INSTALLED IN EXISTING CONDUIT DUCTBANK
FROM AIRFIELD LIGHTING VAULT TO WINDCONE. CONTRACTOR SHALL
NOT REMOVE/IMPAIR CIRCUITS NOT EXPLICITLY INCLUDED IN THE
AFFECTED CIRCUITS. CKT WC-1 IS LAST NON-AFFECTED CIRCUIT.
AFFECTED CIRCUITS THAT ARE DAMAGED BETWEEN THIS POINT AND
THE VAULT ARE TO HAVE CONDUCTORS REPLACED ONLY.
NORTH END WINDCONE PLAN
SCALE: 1" • 75'
a.. a.. a.. z :::; :::; :::; w -, -, -, 3::
z 0 ::izo...w wI Z1--0o:::uOozz
:s::
E-11