Attachments.pdf

PDF 1007 KB Posted

Attached to
Potable Water Testing Services, Buffumville Lake, Charlton, MA
Solicitation number
W912WJ24Q0097
Issued by

About this file

This document is a federal contract solicitation from the Department of the Army Corps of Engineers Engineering District New England for Potable Water Testing Services at Buffumville Lake in Charlton, MA.

The solicitation is set-aside for small business vendors under NAICS code 541380 with a $19 million size standard. The work consists of providing all labor, materials, equipment, and transportation necessary to sample and test potable water at Buffumville Lake in accordance with the attached Performance Work Statement. All vendors must have an active SAM.gov registration to be considered. The solicitation number is W912WJ24Q0097.

View the file

Other files

File Type Posted
APP.pdf PDF
Amendment W912WJ24Q0097-0002.pdf PDF
Solicitation W912WJ24Q0097.pdf PDF
Amendment W912WJ24Q0097-0001.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COMMONWEALTH OF MASSACHUSETTS

DEPARTMENT OF ENVIRONMENTAL PROTECTION

DRINKING WATER PROGRAM

100 CAMBRIDGE STREET, SUITE 900, BOSTON, MA 02114 ● (617) 292-5770

Certificate of Registration

The Department of Environmental Protection

Drinking Water Program Hereby Recognizes the

BUFFUMVILLE PARK

PWS ID # 2054052

as a Registered Public Water System in Massachusetts.

Public Water Systems must comply with the Massachusetts Drinking Water Regulations, 310 CMR 22.00.

Yvette dePeiza, Program Director

Drinking Water Program

Certificate expires December 31, 2024

Please contact the Drinking Water Program if there are any changes in this system.

MassDEP: https:/www.mass.gov/orgs/massachusetts-department-of-environmental-protection https://www.mass.gov/orgs/massachusetts-department-of-environmental-protection

Required Water Quality Sampling Schedule Frequency ForDecember 13, 2022

PWS ID#: 2054052 PWS Name: BUFFUMVILLE PARK

BACTERIA SAMPLING

Apr - Sep:

NCClass:

3 MONTH

Oct - Mar per per

Page 1 of 12023 To 2025

Refer to your MassDEP Coliform Sampling Plan for approved coliform sample locations. Systems open before or beyond the start/end dates must collect samples during these extra months.

Season Start Date: 05/01

Season End Date: 09/30

Town: CHARLTON

Loc ID # SAMPLE LOCATION NAME M/S

QTR1

R/F D/S WAIVER

Y / N QTR1 QTR1QTR2 QTR2 QTR2QTR3 QTR3 QTR3QTR4 QTR4 QTR4

2023 2024 2025

Compliance Period

IRON

01G FINISHED: WELL #1 S F S X

2054052-01G ROCK WELL

MANGANESE

01G FINISHED: WELL #1 S F S X

2054052-01G ROCK WELL

NITRATE

01G FINISHED: WELL #1 S F S N X X X

2054052-01G ROCK WELL

NITRITE

01G FINISHED: WELL #1 S F S N X

2054052-01G ROCK WELL

SECONDARY CONTAMINANTS

[DEP recommends annual testing]01G FINISHED: WELL #1 S F S N

2054052-01G ROCK WELL

SODIUM

01G FINISHED: WELL #1 S F S N X

2054052-01G ROCK WELL

VOLATILE ORGANIC COMPOUNDS

01G FINISHED: WELL #1 S F S N X

2054052-01G ROCK WELL

R/F = (R)aw or (F)inished water D/S = (D)istribution or (S)ource sample Waiver = (Y)es or (N)oM/S= (M)ultiple/Manifold sources or a (S)ingle source Important Notes:

M = Monthly This monitoring schedule is based on the system's current inventory and is subject to change. The system is responsible for promptly reporting errors or omissions.

Errors or omissions on the schedule do not prohibit MassDEP from enforcing monitoring requirements set forth by the Regulations.

Massachusetts Drinking Water Regulations 310 CMR 22.16A (23)

POSTED FOR CUSTOMER REVIEW AS REQUIRED BY THE MASSACHUSETTS DEP/DWP

2054052

BUFFUMVILLE PARK

229 OXFORD RD

CHARLTON MA 01507

The drinking water system at the facility noted above is registered in the Commonwealth as a transient non-community (TNC) public water system because it owns and/or controls its source of water and supplies potable water to 25 or more persons at least 60 days of the year.

Examples of TNCs include restaurants, motels, campgrounds, parks, golf courses, ski areas and community centers.

The drinking water quality monitoring results on file with the Massachusetts Department of Environmental Protection Drinking Water

Program (MassDEP/DWP) for this public water system and period noted above are as follows:

2023 DRINKING WATER QUALITY REPORT

For the period January 1, 2022 to December 31, 2022

All drinking water, including bottled water, may contain small amounts of some contaminants. The presence of contaminants does not necessarily indicate that water poses a health risk.

Detect – any levels found at or above the detection limits in the Massachusetts Drinking Water Regulations, 310 CMR 22.00.

Maximum Contaminant Level (MCL) – the highest level of a contaminant that is allowed in drinking water.

Maximum Contaminant Level Goal (MCLG) – the level of a contaminant in drinking water below which there is no known or expected risk to health.

For any violations, Refer to the following health effects language listed below and contact the system’s contact person for information on corrective actions taken by the system to return to compliance and stay in compliance in the future:

Total Coliform – Coliforms are bacteria that are naturally present in the environment and are used as an indicator that other, potentially harmful, bacteria are present. Coliforms were found in more samples than allowed and this was a warning of potential problems.

Nitrate – Infants below the age of six months who drink water containing nitrate in excess of the MCL could become seriously ill and, if untreated, may die. Symptoms include shortness of breath and blue-baby syndrome.

Nitrite - Infants below the age of six months who drink water containing nitrite in excess of the MCL could become seriously ill and, if untreated, may die. Symptoms include shortness of breath and blue-baby syndrome.

Other Contaminant Violations – If applicable, contact the owner or the MassDEP at the numbers listed below for information on the other contaminants.

** If “Y”, one or more times during the reporting period this system did not monitor and/or report to the MassDEP as required.

“ We are required to monitor your drinking water for specific contaminants on a regular basis. Results of the regular monitor ing are an indicator of whether or not our drinking water meets health standards. During the above noted reporting period we did not monitor or test and/or did not complete all monitoring or testing for contaminant(s) noted above and therefore cannot be sure of the quality of our drinking water during that time. “

The posting of this report meets the public notification Tier 3 requirements of 310 CMR 22.16(4).

Massachusetts Department of Environmental Protection

Bureau of Resource Protection – Drinking Water Program

2002 DRINKING WATER QUALITY REPORT

For the period January 1, 2001 to December 31, 2001

For more information, or the complete monitoring results for this system:

Owner/responsible party name Signature of owner/responsible party Telephone #

Certified Operator Name Signature of certified operator License #

If you have any questions on the Massachusetts Drinking Water Program contact the MassDEP, Drinking Water Program at (617)

292-5770, email program.director-dwp@mass.gov (subject: TNC CCR) or visit the MassDEP web site at www.mass.gov/orgs/massachusetts-department-of-environmental-protection. Contact the EPA Safe Drinking Water Hotline at (800)

426-4791 for more information about contaminants and potential health effects.

Date Drinking Water Quality Report posted______________ Location posted__________________________________________

HIGHEST

DETECT

VALUE

Total Coliform

Nitrate

Nitrite

Sodium

Other Contaminant

Violations5

MCL

MCLG

VIOLATION 4

(YES or NO)

POSSIBLE SOURCES OF

CONTAMINATION

MCL

FAILURE TO

MONITOR **

Naturally present in the environment.

Runoff from fertilizer use; leaching from septic tanks, sewage; and erosion of natural deposits.

Runoff from fertilizer use; leaching from septic tanks, sewage; and erosion of natural deposits.

Naturally present in the environment; may also be due to salt runoff from deicing practices.

MONITORING RESULTS TABLE

CONTAMINANT

N N

N N

N N

N

PWS ID:

N/AN/A N/A N/A N/A

(MG/L)

(MG/L)

(MG/L)

NO DATA

< 0.03

< 0.007

0 0

1 1

N/A N/A N/A

2054052

BUFFUMVILLE PARK

229 OXFORD RD

CHARLTON MA

2023 DRINKING WATER QUALITY REPORT

For the period January 1, 2022 to December 31, 2022

01507

PWS ID:

Per- and Polyfluoroalkyl Substances (PFAS)

REGULATED PER- AND POLYFLUOROALKYL SUBSTANCES (PFAS) RESULTS TABLE

DETECT RANGE1 AVERAGE

DETECT 2

POSSIBLE SOURCES OF

CONTAMINATION

CONTAMINANT HEALTH EFFECTS

PFAS6 *

Discharges and emissions from industrial and manufacturing sources associated with the production or use of these PFAS, including production of moisture and oil resistant coatings on fabrics and other materials.

Additional sources include the use and disposal of products containing these PFAS, such as fire-fighting foams.

Some people who drink water containing these PFAS at elevated levels may experience certain adverse effects. These could include effects on the liver, blood, immune system, thyroid, and fetal development. These PFAS may also elevate the risk of certain cancers.

NO DATA NO DATA

* Sum of PERFLUORODECANOIC ACID (PFDA), PERFLUOROHEPTANOIC ACID (PFHpA), PERFLUOROHEXANESULFONIC

ACID (PFHxS), PERFLUORONONANOIC ACID (PFNA), PERFLUOROOCTANESULFONIC ACID (PFOS), PERFLUOROOCTANOIC ACID (PFOA). PFAS6 was regulated on October 2, 2020. Any detects before that time will be reported in the unregulated table below, if applicable.

1 The lowest and highest detected values. A single value means only one sample was taken.

2 The average detected amount of PFAS6. This is calculated by adding all detected amounts and dividing by the number of samples taken.

Transient Non-Community (TNC) systems are not required to meet the MCL of 20 ppt for PFAS6. MassDEP may perform a site-specific health risk assessment per 310 CMR 22.03(8) for results over 20 ppt.

Per- and polyfluoroalkyl substances (PFAS) are a family of chemicals widely used in common consumer products such as food packaging, outdoor clothing, carpets, leather goods, ski and snowboard waxes, and more. PFAS can leach into groundwater or surface water from surface soils contaminated with PFAS. When ingested, some PFAS can build up in the body, and over time, these PFAS may increase to a level where health effects could occur.

The PFAS Maximum Contaminant Level (MCL) of 0.000020 milligrams per liter (mg/l) or 20 ppt for the sum of six PFAS compounds

(PFOS, PFOA, PFHxS, PFNA, PFHpA, and PFDA) known as PFAS6 is not applicable to transient non-community (TNC) systems, but

TNCs are required to comply with the special applicability requirements of 310 CMR 22.07G(2): Every Supplier of Water operating a

Transient, Non-Community Water System shall collect, analyze and report the results of one sample from each Sampling Point, or alternate sampling location required by the Department pursuant to 310 CMR 22.07G(4)(a) or (b), no later than September 30, 2022.

All such monitoring shall be performed in compliance with the provisions addressing monitoring protocols, invalidation of PFAS samples, PFAS analytical requirements, PFAS reporting requirements, PFAS6 minimum reporting levels and electronic filing requirements set forth in 310 CMR 22.07G(4), (9), (12), (13), (16), (17).

These results are on file with the Massachusetts Department of Environmental Protection Drinking Water Program (MassDEP/DWP).

For more information please contact the persons listed on the first page.

UNREGULATED PER- AND POLYFLUOROALKYL SUBSTANCES (PFAS) RESULTS TABLE

CONTAMINANT (CASRN)

POSSIBLE SOURCE OF

CONTAMINATION

HEALTH EFFECTS

DETECT

RANGE 1

AVERAGE

DETECT 2 ORSG

11-CHLOROEICOSAFLUORO-3-

OXAUNDECANE-1-SULFONIC ACID-11CL-

PF3OUDS (763051-92-9)

ND ND †

4,8-DIOXA-3H-PERFLUORONONANOIC

ACID - ADONA (919005-14-4)

ND ND †

9-CHLOROHEXADECAFLUORO-3-

OXANONE-1-SULFONIC ACID-9CL-

PF3ONS (756426-58-1)

ND ND †

HEXAFLUOROPROPYLENE OXIDE DIMER

ACID - HFPO-DA (13252-13-6)

ND ND †

N-ETHYL

PERFLUOROOCTANESULFONAMIDOACE

TIC ACID - NETFOSAA (2991-50-6)

ND ND †

REGULATED PER- AND POLYFLUOROALKYL SUBSTANCES (PFAS) RESULTS TABLE

PFAS6 *

Discharges and emissions from industrial and manufacturing sources associated with the production or use of these PFAS, including production of moisture and oil resistant coatings on fabrics and other materials.

Additional sources include the use and disposal of products containing these PFAS, such as fire-fighting foams.

Some people who drink water containing these PFAS at elevated levels may experience certain adverse effects. These could include effects on the liver, blood, immune system, thyroid, and fetal development. These PFAS may also elevate the risk of certain cancers.

ND

* Sum of PERFLUORODECANOIC ACID (PFDA), PERFLUOROHEPTANOIC ACID (PFHpA), PERFLUOROHEXANESULFONIC

ACID (PFHxS), PERFLUORONONANOIC ACID (PFNA), PERFLUOROOCTANESULFONIC ACID (PFOS), PERFLUOROOCTANOIC ACID (PFOA). PFAS6 was regulated on October 2, 2020.

1 The lowest and highest detected values. A single value means only one sample was taken.

2 The average detected amount of PFAS6. This is calculated by adding all detected amounts and dividing by the number of samples taken.

Transient Non-Community (TNC) systems are not required to meet the MCL of 20 ppt for PFAS6. MassDEP may perform a site-specific health risk assessment per 310 CMR 22.03(8) for results over 20 ppt.

POSSIBLE SOURCES OF

CONTAMINATION

HEALTH EFFECTSCONTAMINANT DETECT RANGE

1 AVERAGE

DETECT 2

ND

2054052

BUFFUMVILLE PARK

229 OXFORD RD

CHARLTON MA

2023 DRINKING WATER QUALITY REPORT

For the period January 1, 2022 to December 31, 2022

01507

PWS ID:

N-METHYL

PERFLUOROOCTANESULFONAMIDOACE

TIC ACID - NMEFOSAA (2355-31-9)

ND ND †

PERFLUOROBUTANESULFONIC ACID-

PFBS (375-73-5)

ND ND †

PERFLUORODODECANOIC ACID -

PFDOA (307-55-1)

ND ND †

PERFLUOROHEXANOIC ACID - PFHXA

(307-24-4)

ND ND †

PERFLUOROTETRADECANOIC ACID -

PFTA (376-06-7)

ND ND †

PERFLUOROTRIDECANOIC ACID -

PFTRDA (72629-94-8)

ND ND †

PERFLUOROUNDECANOIC ACID -

PFUNA (2058-94-8)

ND ND †

* PFDA, PFHpA, PFHxS, PFNA, PFOS, PFNA were unregulated chemicals from January 1 – October 1, 2020 and had an ORSG of 20 ppt. On October 2, 2020 these chemicals became regulated with an MCL of 20 ppt. Any detects found after that time are reported in the regulated table above as PFAS6.

‡ Sum of PERFLUORODECANOIC ACID (PFDA), PERFLUOROHEPTANOIC ACID (PFHpA), PERFLUOROHEXANESULFONIC

ACID (PFHxS), PERFLUORONONANOIC ACID (PFNA), PERFLUOROOCTANESULFONIC ACID (PFOS), PERFLUOROOCTANOIC ACID (PFOA). PFAS6 was regulated on October 2, 2020.

† There is no ORS Guideline for this compound.

1 The lowest and highest detected values. A single value means only one sample was taken.

2 The average of all sample results between January 1 to December 31, 2021. This is calculated by adding all detected amounts and dividing by the number of samples taken.

3 Office of Research and Standards Guideline (ORSG) - MassDEP health-based guideline.

Appendix M - Guidelines and Policies for Public Water Systems https://www.mass.gov/doc/consumer-confidence-reporting-requirements (1.91 MB)

Satellite Imagery
BVL Park Utilities Design 2022
BVL Park Sampling Map
BVL Park Waterlines 2022
Certificate of Registration (2024) PWS 2054052
Compliance Monitoring Schedule (2023-2025) PWS 2054052
Water Quality Report (Consumer Confidence Report, 2023) PWS 2054052

File details come from the government source that posted it. Updated .