Attachments_1_-_7.pdf

PDF 3 MB Posted

Attached to
DENALI NATIONAL PARK HIGHWAY SIGNS
Solicitation number
140P9724Q0099
Issued by

About this file

This document contains attachments and information related to a federal contract opportunity for manufacturing and installing new highway trailhead signs at Denali National Park and Preserve. The key details are:

The National Park Service, Denali National Park and Preserve, is requesting quotes for a project to provide new highway trailhead signs on the Parks Highway approximately 6 miles south of the Denali Park Road. This project will direct highway users to the new Tsenesdghaas Na' Trailhead that opened in 2024. The solicitation is set-aside 100% for small business concerns under NAICS code 339950 with a 500-employee size standard. The resultant award will be a Firm Fixed Price purchase order. Interested vendors must be actively registered in SAM.gov and submit quotes and questions via email to the contracting officer. The solicitation will be issued under FAR Part 12 and evaluated per FAR Part 13-106(b).

View the file

Other files

File Type Posted
Sol_140P9724Q0099.pdf PDF
Attachment_8_DOL_Wage_Determination.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

For the best experience, open this PDF portfolio in

Acrobat X or Adobe Reader X, or later.

Get Adobe Reader Now!

http://www.adobe.com/go/reader

Northbound Trailhead Sign

Speed Limit - 65

Material: Aluminum

Scale: 1/2” = 1’ - 0”

Cap Height - 6”

Size: 144“ x 18”

Symbols - 24”

Size: 24“x 24”

Park Road 6 Miles Ahead

Cap Height - 8”

Size: 144“ x 66”Tsenesdghaas Na' Trailhead

Southbound Trailhead Sign

Tsenesdghaas Na' Trailhead

Symbols - 24”

Size: 24“x 24”

Cap Height - 8”

Size: 144“ x 66”

TADEUSZ TOMASIC

CE 124564

TADETTTTTTATTTTTTATTTTTTTTTT USZ TOMASIC

4.18.2022 kdoniere

Polygon

Ellipse

PolyLine

Line

Text Box

Nenana River

New Sign A:

Station 2545+00

A

A lminski

Denali Grizzly Bear Resort

Northbound - Trailhead Sign

Cloud

Drive with Headlights sign here to be removed

Callout

Remove existing "Welcome to Denali National Park and Preserve" sign. Maintain hiker symbol and one post.

Remove

Image

TADETATTTTATATTTATTTATATTTTTTTTTATA USZ TOMASIC

B

Southbound - Trailhead

Trailhead/Rest Area Road Access

Maintain hiker symbol

B

New Sign B: Station 2557+00

Alaska Highway Preconstruction Manual 1170-9 1170. Special Design Elements Effective December 15, 2011

C.G. C.G.

W

C.G.

0.2W0.2W 0.6W

MaximumSign Area per Post is 25 sf Maximum Light Sign Area per Structure is 50 sf

LIGHTSIGNSTRUCTURES

< 50 sf

0.2W 1 space at 0.6W 0.2W 2 posts 0.15W 2 spaces at 0.35W 0.15W 3 posts 0.125W 3 spaces at 0.25W 0.125W 4 posts 0.1W 4 spaces at 0.2W 0.1W 5 posts

MaximumSign Area per Post is 60 sf Heavy Structured Signsmay require framing.

See Standard Drawing S.00.00.

HEAVYSIGNSTRUCTURES

>50 sf

SIGN POST DESIGN SPECIFICATIONS

GENERAL NOTES for SIGN POST

SELECTION

1. Design based on the following Post Material:

Steel conformed to the requirements of ASTM A501 for Steel Tubing, ASTM A53 for Steel Pipe standard weight, ASTM 36 for W Shape Beams, and ASTM 446 for Perforated Tubing. Sawed Wood Post material shall conform to AASHTOM168.

2. Solid lines on Figure 1170-5 through 1170-10 indicate maximum use of the indicated post. Any combined value of sign area and height to the right or above the solid line indicates the use of the next larger post.

3. Fracture posts or slip bases shall be used for all Posts in the clear zone.

4. Designer should determine the type of sign support by the following: Wind velocities expected in the project area, location of sign in sheltered or exposed areas, temporary or permanent type sign, expected life of sign, maintenance cost in relation to construction cost.

Figure 1170-2 Sign Post Design Specifications

Tsenesdghaas Na' Trailhead - Highway Signage Denali National Park and Preserve

2024-08-26 DRAFT

Proposed sign size:

12' (w) x 5.5' Use (2) posts For "H", see page 5

Rectangle

Center space = 8' (use 2 posts)

Side space (Typ.) = 2.4'

1170. Special Design Elements 1170-10 Alaska Highway Preconstruction Manual

Figure 1170-3

Wind Isotach for 10-Year Interval

Tsenesdghaas Na' Trailhead - Highway Signage

Approximate Project Location

1170. Special Design Elements 1170-14 Alaska Highway Preconstruction Manual

Figure 1170-7 Sign Post Selection 60 mph Design Wind Velocity

0 10 20

Sign Area in Sq. Ft. per Post

2 4 6 8 12 14 16 18 22 24

26 36 4628 30 32 34 38 40 42 44 48 50 52 54 56 58 60

H ei gh t( ft)

SIGN POST SELECTION

60 MPH DESIGN WIND VELOCITY

1.5“ P 2 x 2 TS

4 x 4 W

2“ P

2.5 x 2.5 PT

2.5“ P 4 x 6 in. W 3 x 3 TS

6 x 6 W

4 x 6W

3 x 3 TS

3 P

3.5 x 3.5 TS

3.5“ P

4 x 4 TS 6 x 8W

4“ P 5 x 5 TS W6 x 9

5“ P

POST MATERIAL

P...........Steel pipe (std. wt.)

P.T........Perforated steel tubing (0.105 in. wall) TS.........Steel tube square (0.1875 in. wall) _x_ W....Treated wood W_x_.....Steel W shapes

Tsenesdghaas Na' Trailhead - Highway Signage

Sign size = 12' x 5.5' = 66 square feet

With (2) Posts = 33 sf per post

Posts to be 5x5 TS (steel tube square - since not using circular pipe (see detail sheet TSM407) or W6x9

H = not to exceed 15', shall not be less than 11'

NIGN

R

DERE

SIG

E

T

SP OR SEF

ELANIO

REE

POST MOUNTED SIGN

OFFSET AND HEIGHT

SIGN POST BASE AND

FOUNDATION

Binder1.pdf

TSM407.pdf

AKDOT_Alaska Standard Plans_2024.pdf s0012

AKDOT_Alaska Standard Plans_2024.pdf s0502

Sheets and Views

ASP s0502-Model

AKDOT_Alaska Standard Plans_2024.pdf s3102

Sheets and Views

ASP s3102-Model

AKDOT_Alaska Standard Plans_2024.pdf s3005

Cap Height - 6”

Size: 78“ x 54”

Boundary Sign

Denali

National Park and Preserve

ENTERING

TADETTTTTTATTTTTTATTTTTTTTTT USZ TOMASIC

Nenana River

Denali Grizzly Bear Resort

Boundary Sign

New Boundary Sign, Station 2542+28 (If existing post is in good condition it can be re-used)

Existing post

Alaska Highway Preconstruction Manual 1170-9 1170. Special Design Elements

C.G. C.G.

C.G.

0.2W0.2W 0.6W

MaximumSign Area per Post is 25 sf Maximum Light Sign Area per Structure is 50 sf

LIGHTSIGNSTRUCTURES

< 50 sf

0.2W 1 space at 0.6W 0.2W 2 posts 0.15W 2 spaces at 0.35W 0.15W 3 posts 0.125W 3 spaces at 0.25W 0.125W 4 posts 0.1W 4 spaces at 0.2W 0.1W 5 posts

MaximumSign Area per Post is 60 sf Heavy Structured Signsmay require framing.

See Standard Drawing S.00.00.

HEAVYSIGNSTRUCTURES

>50 sf

SIGN POST DESIGN SPECIFICATIONS

GENERAL NOTES for SIGN POST

SELECTION

1. Design based on the following Post Material:

Steel conformed to the requirements of ASTM A501 for Steel Tubing, ASTM A53 for Steel Pipe standard weight, ASTM 36 for W Shape Beams, and ASTM 446 for Perforated Tubing. Sawed Wood Post material shall conform to AASHTOM168.

2. Solid lines on Figure 1170-5 through 1170-10 indicate maximum use of the indicated post. Any combined value of sign area and height to the right or above the solid line indicates the use of the next larger post.

3. Fracture posts or slip bases shall be used for all Posts in the clear zone.

4. Designer should determine the type of sign support by the following: Wind velocities expected in the project area, location of sign in sheltered or exposed areas, temporary or permanent type sign, expected life of sign, maintenance cost in relation to construction cost.

Figure 1170-2 Sign Post Design Specifications

Boundary Sign

2024-08-30 DRAFT

Proposed sign size:

6.5' (w) x 4.5' Use (2) posts For "H", see page 5

Side space (Typ.) = 1.3'

Center space = 3.9'

1170. Special Design Elements 1170-10 Alaska Highway Preconstruction Manual

Figure 1170-3

Wind Isotach for 10-Year Interval

Approximate Project Location

Boundary Sign

1170. Special Design Elements 1170-14 Alaska Highway Preconstruction Manual

Figure 1170-7 Sign Post Selection 60 mph Design Wind Velocity

0 10 20

2 4 6 8 12 14 16 18 22 24

26 36 4628 30 32 34 38 40 42 44 48 50 52 54 56 58 60

SIGN POST SELECTION

60 MPH DESIGN WIND VELOCITY

1.5“ P

4 x 4 W

2“ P

2.5 x 2.5 PT

2.5“ P 4 x 6 in. W 3 x 3 TS

6 x 6 W

4 x 6W

3 x 3 TS

3 P

3.5 x 3.5 TS

3.5“ P

4 x 4 TS 6 x 8W

4“ P 5 x 5 TS W6 x 9

5“ P

POST MATERIAL

P...........Steel pipe (std. wt.)

P.T........Perforated steel tubing (0.105 in. wall) TS.........Steel tube square (0.1875 in. wall) _x_ W....Treated wood W_x_.....Steel W shapes

Sign size = 29.25 square feet

With (2) Posts =

14.625 per post

Posts to be 3x3 TS (steel tube square - since not using circular pipe (see detail sheet TSM407)

H = not to exceed 15', shall not be less than 11'

Boundary Sign

File details come from the government source that posted it. Updated .