Attachment1SalientCharacteristicsforDeltaHDefenderFurnace.pdf
PDF 95 KB Posted
- Solicitation number
- 202609250001
About this file
This document is a salient characteristics specification for a Metals Technology DELTA H DEF-DC-RH-241236/2000-RH-241636/2000-SR dual chamber aerospace heat treating furnace system. The furnace is specifically designed for military aircraft maintenance and heat treatment of PH stainless, titanium, and ferrous alloys. It meets requirements of T.O. 1-1A-9 and qualifies to AMS2750H certification standards.
The furnace features dual radiant heat chambers, each with a maximum operating temperature of 2000°F and certified Class 3 temperature uniformity within ±15°F from 1200-2,000°F. The upper chamber has a certified work volume of 24"W x 12"H x 36" deep, while the lower chamber measures 24"W x 16"H x 36" deep. Both chambers include permanently installed base metal non-expendable thermocouple wire at nine positions for temperature uniformity surveys and one position for system accuracy tests, gas-tight construction with flow control and alarms. The system includes digital paperless process recording with AMS2750H monitoring software and AFTO Form 8 template capability, independent programmable Eurotherm controllers with multiple profiles and high-temperature limit controls, Type C instrumentation for recording critical data, and a roll-away oil quench tank with 16-inch parts capacity and temperature recording capability. Additional components include full documentation manuals, electrical schematics, bill of materials, and safety features such as door safety switches. The overall dimensions are 90"H x 66"W x 102"L with a weight of 5,500 pounds, with freight service provided FOB.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment1SalientCharacteristicsforDeltaHDefenderFurnace.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics for Metals Technology Dual Chamber Furnace
1) Salient Characteristics:
- DELTA H DEF-DC-RH-241236/2000-RH-241636/2000-SR
- Dual Chamber Aerospace Heat Treating furnace system designed specifically for military aircraft maintenance heat treating of PH stainless, titanium, and ferrous alloys.
- Meets requirements of T.O. 1-1A-9 and qualifies to AMS2750H
- Certified Temperature Uniformity Survey (TUS) Work Volume:
o Radiant Heat Chamber (upper) 2000°F Certified TUS Work Volume: 24“W x 12“H x 36“ Deep o Meets Class 3, +/- 15°F to 1200-2,000°F o Permanently installed Base Metal Non-Expendable Thermocouple wire at nine positions for Temperature uniformity surveys and a single position for system accuracy tests o Gas Tight Chamber w/gas flow control and flow alarm o Radiant Heat Chamber (lower) 2000°F Certified TUS Work Volume: 24“W x 16“H x 36“Deep o Meets Class 3, +/- 15°F to 1200-2,000°F o Permanently installed Base Metal Non-Expendable Thermocouple wire at nine positions for Temperature uniformity surveys and a single position for system accuracy tests o Gas Tight Chamber w/gas flow control and flow alarm
- Digital Paperless Process Recorder w/tamperproof Batch Reporting & AMS2750H Process Monitoring Software with AFTO Form 8 template
- Analog input card to connect Furnace to existing DCAHT Furnace calibration equipment
- Eurotherm Recorder to track thermal couple usage, TUS, SAT, calibration intervals, and/or change dates
- Type C Instrumentation Records TUS, High & Low locations, Air Control Temp, and Quench Temp
- Independent programmable temp Eurotherm controllers w/multiple profiles, high temp limit controls, and End of Cycle/Temp Deviation alarms and Silence buttons
- National Fire Protection Association Std Compliant Documentation
- Full electrical schematic, bill of materials/list of spares, Operation, Maintenance, and Calibration/Certificate Records manuals
- Roll-away oil quench tank, 16 inch high parts capacity, oxidation resistant lining, heavy duty casters, with included temperature recording thermocouple and quench agitator
- Overall Size/Wt: 90"H x 66"W x 102"L – 5,500 lb
- Programmable controls for independent program operations in either set point or programmable modes.
- Removable control panel for easy maintenance.
- Door safety switch included to remove power from elements when door is open.
- Freight Service; FOB
File details come from the government source that posted it. Updated .