Attachment - VA Palo Alto Updated Drawings 12.12.22.pdf

PDF 292 KB Posted

Attached to
4250--640-23-1-5043-0017 rtn'd 11/30) Compose and recycle compactors
Solicitation number
36C26123Q0273
Issued by

View the file

Other files

File Type Posted
36C26123Q0273.docx DOCX document
Attachment - ANSI Z245.2-1997.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

6"

DOCK

OVERLAP

DRAIN LINE TO BE PROVIDED

UNDER DOCK SURFACE

(CUSTOMER-FURNISHED)

UNIT;3

C O

N

TA

IN

ER

C O

M

PA

C

TO

R

EXISTIN

G

UNIT;3

EXISTING BOLLARDS (TYP.)

96 GAL. COMPOST WASTE CART

SELF-C

O

N

TA

IN

ED

(20 C

U YD)

CART DUMPER

(UNDER PLATFORM)

RO

LL-O

FF

EXISTING BREAK AWAY CONTAINER

EXISTING SANITARY DRAIN

COMPACTOR POWER

COMPOST WASTE

SELF-CONTAINED

SELF-CONTAINED

COMPACTOR POWER

EXISTING PLATFORM TO BE

REMOVED BY CUSTOMER

PRIOR TO INTSALL

APPROX.

8'-4"

OVERALL

25'-11"

PLATFORM LENGTH

AREA

LENGTHCART WASH AREA LENGTH

38'-9"

7'-8"

WIDTH

APRROX.

WIDTH

LENGTH 6'-8"

17'-0"

APPROX.

EQUIPMENT

PLATFORM

20'-0" RAMP

2'-4"

22'-6"

CART WASH

OVERALL EQUIPMENT WIDTH

6'-0"

46'-7"

15'-8"

7'-8"

APPROX.

10'-6"

17'-8"

APPROXIMATE

38'-5"

APPROXIMATE

REC

YC

LIN

G

SELF-C

O

N

TA

IN

ED

C O

M

PA

C

TO

R (35 C

U YD)

PRESENTED IN THIS SITE PLAN (INSTALLATION DRAWINGS)

SAN-I-PAK IS ONLY QUOTING THE EQUIPMENT DRAWN IN COLOR

VAMC PALO ALTO - PALO ALTO,CA

PLEASE MAKE ANY CHANGES OR CORRECTIONS AND RETURN FOR REDESIGN OR SIGN YOUR ACCEPTANCE AND RETURN A COPY OF THE SITE DRAWINGS TO SAN-I-PAK @ P.O. BOX 1183 TRACY, CA 95378-1183.

DATEDEPARTMENT

1” STEAM LINE CONNECTION MUST BE AT A MINIMUM OF 65 PSI & A MAXIMUM OF 100 PSI AT THE

COMMENTS:

DATE INITIALS

TITLE:

CART WASH AREA

SPN-22-1323

SERVICE

SHOP FOREMAN

ELECTRICAL

SIZE

SHEET 1 OF 4

UT

IL

ITY

N

O

TE

S:

SERVICE

DWG. NO.

5/12/22

INITIALS

THIS IS NOT A VALID DRAWING UNLESS

CUSTOMER, & SANIPAK, INC.

DEPARTMENT

PRESIDENT

PH

A

SE

G

EN

ER

A

L N

O

TE

S:

22-1323

VALVE (ACCESSIBLE FROM MACHINE).

JVF

SIGNED IN THE TITLE BLOCK. NOT FOR

1.

RFQ #:

CONSTRUCTION UNTIL APPROVED BY BPROGRAMMING/

PRESIDENT

DATE INITIALS

SHOP FOREMAN

ELECTRICAL

SAN-I-PAK EQUIPMENT IS TO BE PAINTED SAN-I-PAK BLUE UNLESS OTHERWISE NOTED.

ALTERATIONS TO THE DIMENSIONS OR ARRANGEMENT PRIOR TO THE START OF MANUFACTURING. ANY ALTERATIONS, DELETIONS OR OTHER CHANGES TO ACTUAL SITE WHICH ARE NOT REFLECTED IN THE DRAWINGS FURNISHED BY SAN-I-PAK MAY RESULT IN ADDITIONAL COSTS OVER AND

EQUIPMENT; ABOVE 100 PSI REQUIRES A PRV STEAM LINE REQUIRES A PRESURE GAUGE AND SHUT OFF

CONTAINED COMPACTOR, 20 CU. YD.

DRAWN

PHASE 1

6.ALL FINAL UTILITY CONNECTIONS (STEAM, WATER, ELECTRICAL) ARE THE RESPONSIBILITY OF THE CUSTOMER.

5.HIGH VOLTAGE CABINET; ELECTRICAL VOLTAGE TO BE 480V.

4.ALL SANITARY DRAINS ARE EXISTING OR CUSTOMER FURNISHED.

CONDENSATE TANK TO THE SANITARY DRAIN.

3.CONDENSATE TANK DRAIN HAS A 2” FLANGE; CUSTOMER IS RESPONSIBLE FOR PLUMBING FROM THE

REQUIRES A PRV. CUSTOMER TO SUPPLY SHUT OFF VALVE (ACCESSIBLE FROM MACHINE).

2.1/2" WATER LINE CONNECTION MUST BE AT A MINIMUM OF 30 PSI & A MAXIMUM OF 60 PSI; ABOVE 60 PSI SELF-CONTAINED COMPACTOR AND

. WE WILL BUILD TO THE EXACT DIMENSIONS SHOWN. WE ASK THE CUSTOMER TO CAREFULLY REVIEW THESE DRAWINGS AND REQUEST ANY CHANGES OR

REV

35 CU. YD. RECYCLING SELF-

K. BLAS

ABOVE THE ORIGINAL QUOTE AND MAY BE PASSED ON TO THE CUSTOMER.

6.

A A

B B

C C

D D

PHASE:

SAN-I-PAK REPRESENTATIVE:

ALL DIMENSIONS ARE TO BE VERIFIED BY CUSTOMER1.

REQUIRED CONCRETE PAD THICKNESS MINIMUM IS 6” THICK, 3000 PSI FOR TOTAL LENGTH INCLUDING FULL 2.

LENGTH GUIDE CHANNELS.

MOUNTING OF SAN-I-PAK UNIT TO CONCRETE PAD IS ACCOMPLISHED WITH WEDGE ANCHOR BOLTS. 3.

PRECAST CONCRETE PAD IS NOT RECOMMENDED.

ANY SLOPE EXCEEDING 1 INCH IN 10 FEET IN ANY DIRECTION ON THE EQUIPMENT MOUNTING SURFACES 4.

MUST BE NOTED IN THE SITE SURVEY. THEREFORE, SHOWN ON THIS DRAWING; PLEASE CONFIRM. EXCESSIVE

SLOPES MAY REQUIRE ADDITIONAL INSTALLATION & DESIGN EXPENSE.

LOADING DOCK HEIGHT IS 48".5.

PROGRAMMING/

PH

A

SE

12/12/2022

9'-6"

CART

DUMPER

CLEARANCE

20 CU. YD. SELF-CONTAINED COMPACTOR

35 CU. YD. RECYCLING SELF-CONTAINED COMPACTOR

EXISTING BREAK-AWAY CONTAINER

SELF-CONTAINED COMPACTOR

POWER UNIT;3

COMPOST WASTE CART DUMPER

COMPACTOR (35 CU. YD.)

(UNDER PLATFORM)SELF-CONTAINED COMPACTOR POWER UNIT; 3

RECYCLING SELF-CONTAINED

96 GAL. COMPOST WASTE CART

8'-4"

" 8'-6

CART WASH AREA

WIDTH

APPROXIMATE

8'-3 1

48"

DOCK

HEIGHT

35 CU. YD. RECYCLING SELF-

CONTAINED COMPACTOR, 20 CU. YD.

SELF-CONTAINED COMPACTOR AND

CART WASH AREA

VAMC PALO ALTO - PALO ALTO,CA

DWG. NO. REV

COMMENTS:

DATE INITIALS

TITLE:

SIZE

B

5/12/22

PHASE: SHEET 2 OF 4

A A

B B

C C

D D

PH

A

SE

DATE INITIALS

SERVICE

DEPARTMENT

CUSTOMER, & SANIPAK, INC.

22-1323

ELV-22-1323

K. BLAS

RFQ #:

JVF

SAN-I-PAK REPRESENTATIVE:

PHASE 1

DRAWN

INITIALSDATE

PRESIDENT

CONSTRUCTION UNTIL APPROVED BY

ELECTRICAL

SHOP FOREMAN

SERVICE

DEPARTMENT

PRESIDENT

PROGRAMMING/

ELECTRICAL

SHOP FOREMAN

THIS IS NOT A VALID DRAWING UNLESS

SIGNED IN THE TITLE BLOCK. NOT FOR

PROGRAMMING/

PH

A

SE

RECYCLING SELF-CONTAINED COMPACTOR (35 CU YD)

SELF-CONTAINED COMPACTOR (20 CU YD)

CART WASH AREA

CART DUMPER

COMPOST WASTE

96 GAL. COMPOST WASTE CART

35 CU. YD. RECYCLING SELF-

CONTAINED COMPACTOR, 20 CU. YD.

SELF-CONTAINED COMPACTOR AND

CART WASH AREA

VAMC PALO ALTO - PALO ALTO,CA

5/12/22

PHASE:

COMMENTS:

DATE INITIALS

TITLE:

SIZE

B

DEPARTMENT

PH

A

SE

SHEET 3 OF 4

A A

B B

C C

D D

22-1323

DATE INITIALS

SERVICE

DWG. NO.

RFQ #:

REV

CUSTOMER, & SANIPAK, INC.

K. BLAS

ISO-22-1323

JVF

SAN-I-PAK REPRESENTATIVE:

PHASE 1

DRAWN

INITIALSDATE

PRESIDENT

CONSTRUCTION UNTIL APPROVED BY

ELECTRICAL

SHOP FOREMAN

SERVICE

DEPARTMENT

PRESIDENT

PROGRAMMING/

ELECTRICAL

SHOP FOREMAN

THIS IS NOT A VALID DRAWING UNLESS

SIGNED IN THE TITLE BLOCK. NOT FOR

PROGRAMMING/

PH

A

SE

5'-0" 6" 8"

8'-6"

/40A480V/3

(CUSTOMER-FURNISHED)

UNDER DOCK SURFACE

DRAIN LINE TO BE PROVIDED

480V/3 /40A

EXISTING PLATFORM TO BE

REMOVED BY CUSTOMER

PRIOR TO INTSALL

35 CU. YD. RECYCLING SELF-

CONTAINED COMPACTOR, 20 CU. YD.

SELF-CONTAINED COMPACTOR AND

CART WASH AREA

VAMC PALO ALTO - PALO ALTO,CA

. DATE:

DUCTION IN PART OR AS A WHOLE

UTILITY LOCATION

CONSTRUCTION UNTIL APPROVED BY

SERVICE

SANIPAK PACIFIC, INC. IS PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

DRAWN

SHOP FOREMAN

PHASE 1

PHASE 2

COMMENTS:

DATE INITIALS

TITLE:

SIZE

BAND MACHINE VARIANCES. CUSTOMER IS RESPONSIBLE FOR INSTALLING UTILITIES ACCORDING TO THE BUILDING CODES AS SPECIFIED IN YOUR AREA.N O

TE

SHEET 4 OF 4

A A

B B

C C

D D

DWG. NO.THAT MAY OCCUR TO UTILITY LINES DUE TO INTERFERENCE DURING INSTALLATION. UTILITY LOCATIONS ARE ESTIMATED AND WILL VARY +-6" DUE TO SITE

PHASE:

N/A

WITHOUT THE WRITTEN PERMISSION OF

REV

CUSTOMER APPROVAL:

JVF

22-1323

CUSTOMER, & SANIPAK, INC.

UTL-22-1323

K. BLAS

SAN-I-PAK REPRESENTATIVE:

SIGNATURE:

RFQ #:

SANIPAK PACIFIC, INC. ANY REPRO-

5/12/22

UTILITIES

SIGNED IN THE TITLE BLOCK. NOT FOR

THE INFORMATION CONTAINED IN THIS

DRAWING IS THE SOLE PROPERTY OF

THIS IS NOT A VALID DRAWING UNLESS

DO NOT INSTALL UTILITIES TO CONNECTION POINTS UNTIL AFTER INSTALLATION OF SAN-I-PAK MACHINE. SAN-I-PAK IS NOT RESPONSIBLE FOR ANY DAMAGE CONDENSATE TANK LOCATION:

2022-12-12T15:23:17-0800
Digitally verifiable PDF exported from www.docusign.com

File details come from the government source that posted it. Updated .