This file is an attachment to a federal solicitation for certified industrial hygienist services. The solicitation is number 697DCK-23-R-00598 and was issued by the Department of Transportation Federal Aviation Administration Southwestern Region to support the DIA ATCT Modernization project. Offerors are required to submit a microbial remediation plan as Attachment J-1D detailing their proposed approach, procedures, and credentials for performing industrial hygiene services including microbial sampling and remediation if needed at the project site. The solicitation appears to seek these services for the modernization of an air traffic control tower but does not specify response dates, award amounts, or other contractual terms.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Microbial Remediation Plan

For

Guardian Construction Denver International Airport

DEN Modernize Phase II

Submitted by:

Major Asbestos Control, Inc.

202 S. County Rd. 21

Berthoud, Colorado 80513 970-532-4855

Table of Contents

Section a …… Description of materials to be remediated

Section b……..Types of Biocides and fungicidal agents

Section c……. Containment procedure

Section d…….Personal protective equipment

Section e…….Construction barricades and barriers in occupied areas

Section f……..HVAC shut down and start-up procedures

Section g……..HVAC evaluation and remediation procedures

Section h……..Moisture and relative humidity control procedures and equipment

Section i………Packaging and disposal procedures

Section j………Safety precautions

Section k……...Cross contamination control

Section a

Description of materials to be remediated

Concourse C Tower:

• Removal and disposal of approximately 25 square feet of drywall located in the ATCT Penthouse at the

East and South West exterior walls.

• Removal and disposal of approximately 400 square feet of exterior damaged drywall soffits located above the north, south and east walkways between he microwave balconies.

• Sub Junc: Removal and disposal of approximately 75 square feet of interior drywall and 10 linear feet of vinyl cove base located in the ATCT subjection level mechanical room 527 at the East wall.

• Level 13: Removal and Disposal of approximately 100 square feet of drywall located in the ATCT level 13 stairwell vestibule room 1306 specified walls, as well as specified drywall located in the mechanical chase.

• Level 12: Removal and disposal of approximately 20 square feet of drywall located on room 1205 West wall and room 1206 at the base of the North and East walls.

• Level 11: Removal and disposal of approximately 325 square feet of damaged drywall located on the North wall in the stairwell between levels 11 and 12, as well as approximately 20 square feet of drywall located n room 1106 on the North wall and ceiling.

Base Building:

• Removal and disposal of approximately 50 square feet of drywall located in room 107 at the lower portion of the North wall

• Removal and disposal of approximately 80 square feet of drywall walls located in room 112 at the North

East corner of the room

• Removal and disposal of approximately 30 square feet of interior drywall walls located in room 114 at the base of the East, South and West walls.

• Removal and disposal of approximately 20 square feet of interior drywall walls located in room 116 (Stair no.2) at the base of the East and South Walls.

• Removal and disposal of approximately 80 square feet of drywall walls located in room 118 (Mech. Room) at the base of the North wall

• Removal and disposal of approximately 160 square feet of drywall walls located in rom 119 (Boiler room) in the South West and North East corners of the room.

• Removal and disposal of approximately 200 square feet of drywall walls located in room 120

• Removal and disposal of approximately 25 square feet of drywall located below the window sills throughout room 203

• Level 2: Removal and disposal of approximately 45 square feet of drywall located in level 2 room 201 soffit and wall below Base Building:

• Removal and disposal of approximately 60 square feet of interior drywall walls and associated insulation located at each perimeter unit heater located throughout the 2nd and 3rd floor of the base building.

• Room 102: Removal and disposal of approximately 60 square feet of drywall located on the perimeter walls at each corner.

OBSERVATIONS & FINDINGS

There is a heat exchanger located in the southwest corner of the boiler room that is leaking and is the source of moisture that has allowed mold to develop in this part of the boiler room and the adjacent locations. The leak from this heat exchanger cannot be fixed without shutting down the heating/cooling system for the building. This is being addressed as part of the boiler replacement project, which will include the installation of temporary boilers to allow the building to remain occupied while the project is completed.

Water damage was evaluated in the boiler room, and any adjacent locations possibly affected by the water leak from the heat exchanger. Some amount of fungal growth (mold) contamination was determined to exist associated with building materials (wallboard) at four (4) of the five (5) suspect locations.

1. Boiler Room (119) - Wallboard in contact with water from the heat exchanger has allowed mold to develop at the base of the walls in the southwest corner. Mold exists (mainly behind vinyl base) at the base of the south and west walls in the boiler room as a result of the heat exchanger leak. Unrelated to the heat exchanger leak, a small amount of historic water damage/mold was determined to exist at the base of the wall in the northeast corner of the boiler room in the vicinity of the hot water heater. Currently, there was no moisture identified at this location and the minimal damage that exists is believed to be historic in nature.

Mold was sampled at the base of the west wall in the boiler room and determined to be Penicillium/Aspergillus, and Ulocladium species. There is approximately 15 square feet of mold behind the vinyl base at this location with an unknown amount inside of the wall cavity. On the east wall, behind the water heater there is <1 square foot of mold also at the base of the wall behind the vinyl base.

Remediation will require the removal of wallboard to a height of 4 feet from the entire south and west walls, and approximately 10 linear feet from the northeast corner. Approximately 200 square feet of wallboard will need to be removed in the boiler room to address the current mold concerns. It is recommended that, as part of the project, the bottom 4 feet of wallboard be removed from all of the boiler room walls and replaced with materials more resistant to water damage and mold such as glass fiber faced Gypsum Wall Board, or equivalent. Consult with Building Science Corporation (BSC) with regard to wallboard replacement material for the boiler room.

2. Mechanical (118) – Water damaged wallboard and small amounts of mold were determined to exist at the base of the north wall that is shared with the boiler room. Again, the mold identified was only at the base of the wall and behind the vinyl base, and is the result of the heat exchanger leak.

There is approximately 5 square feet of mold behind the baseboard at this location with an unknown amount inside of the wall cavity. Remediation will require the removal of wallboard to a height of 4 feet from the north mechanical room wall, adjacent to the boiler room, from the doorway to the northwest corner and a small section of the west wall. Approximately 80 square feet of wallboard will need to be removed from this location to address the current mold concerns.

3. CCMS (112) – Mold was found to exist in the northeast corner of the CCMS room and at this location the mold was visible to a height of about 2 feet up the wall behind a storage cabinet. Unlike in the boiler and mechanical rooms, where it appears that residual heat in the area has likely dried moisture from the wallboard minimizing mold growth on the exposed wall surface, conditions in the CCMS have allowed mold to develop on the exposed surface and not just behind the vinyl base. There is over 10 square feet of mold contamination on finished surfaces at this location.

Mold was sampled on the east wall in the CCMS room and determined to be Stachybotrys species. Remediation will require the removal of wallboard to a height of 4 feet from the east, north and a small section of the west walls.

Approximately 80 square feet of wallboard will need to be removed from the CCMS room. Sealing the return air vent and minimizing access into the CCMS room is recommended to help minimize any potential for exposure should the exposed mold be inadvertently disturbed prior to its removal.

4. Fiber Optics Electronics (111) – The northeast corner of Room 111, that is adjacent to the areas of concern, was evaluated by removing the vinyl base, testing for moisture, and visually inspecting for signs of water damage and mold.

Findings in this area were unremarkable as signs of water damage/mold in this area were not identified. Remediation at this location is not necessary.

5. Stair No. 1 (102) – Moisture was determined to exist in the south wall of the stairwell to a height of about 2 feet above the bottom level of the stairs. Mold was observed behind the vinyl base at this same location, which is adjacent to both the boiler room and the CCMS water damaged locations. Mold was not observed on the finished walls above the vinyl base.

Mold was sampled from behind the base on the south wall of Stair No. 1 and determined to be Penecillium/Aspergillus and Stachybotrys species.

Remediation will be required to remove the wallboard to a height of 4 feet from the south and east walls at this location. Approximately 56 square feet of wallboard will need to be removed from this location. The thickness and number of layers of wallboard that will need to be removed will need to be field verified.

CONCLUSIONS & DISCUSSION

Mold remediation will need to occur in the identified locations and should occur in conjunction with the current boiler replacement project. Based upon the visual observations, evaluation, and review of all available data, GA recommends that the following remediation steps be conducted. The goal of remediation is to clean or remove the materials affected by fungal growth in a way that prevents the emission of fungi and dust contaminated with fungi from leaving the work area and entering other areas of the building.

Project Sequence -

As with any water damage/fungal growth event, the source of the moisture needs to be identified and corrected prior to or in conjunction with any remediation, in order to minimize the possibility of the fungal growth problem reoccurring. As work in the boiler room will be necessary in order to address the source of the water that has caused the noted damage, sequencing the remediation with the construction work will be necessary.

It is recommended that the following actions be completed in the boiler room in order to help ensure a successful project.

1. Walls inside of the boiler room that are contaminated with mold should be protected to ensure that the mold is not disturbed by work/demolition activities inside of the boiler room. This can be accomplished by installing plywood along the bottom of the west and south walls of the boiler room at any location that could possibly be damaged. The plywood should be held up off the floor so that it does not wick moisture.

2. Complete the cutover and install for the temporary boilers. Ensure that work activities, including temporary plumbing and electrical work, do not disturb any of the identified mold contaminated wall locations.

3. Complete demolition work of equipment from inside of the boiler room. Again, ensure that work activities do not disturb identified mold contaminated locations.

4. Remediate the mold/water-damaged materials from the boiler room and adjacent locations. Complete necessary inspections, testing, and rebuild. It is estimated that this work activity will require approximately 2 weeks to complete.

5. Continue with boiler replacement project work.

Necessary water damage and mold remediation activities based upon findings to date:

• The attached interior remediation procedures shall be utilized for the removal of all interior wallboard that is water damaged and any associated insulation in the Boiler Room and adjacent locations.

The potential health hazard for building occupants and maintenance personnel to the fungal growth material that has been identified is currently minimal. Addressing the materials identified as recommended will help ensure that the risk to personnel and the facility are appropriately managed.

REMEDIATION COST ESTIMATE

Estimated costs for this remediation work to be conducted at this location:

$ 11,250.

Estimated costs for remediation oversight and project clearance:

$ 7,400.

REMEDIATION RECOMMENDATIONS

Appendix A – Boiler Room and Adjacent Locations

Interior Remediation Procedures

These recommendations are designed to assist in the interior evaluation, removal and cleanup of materials contaminated or likely contaminated with visible fungal growth and surfaces contaminated with fungal contaminated dust. These remediation procedures should be completed in the order provided and documentation that each step was properly completed should be maintained. All remediation and clearance work activities shall be completed in accordance with the FAA’s ATO IAQ Program Implementation Requirements – Chapter 5.

1. Identify and correct all potential sources of moisture intrusion – remove leaking heat exchanger.

2. Remediation workers shall be trained in the handling of hazardous waste materials and the health effects of fungal growth.

3. Proper protection for remediation workers should at least consist of, disposable protective coveralls, eye protection, gloves, and a properly fitted NIOSH-approved respirator with P-100 HEPA filters.

4. All contents within the designated work areas (Boiler Room and adjacent contained locations) shall be inspected, cleaned with a high efficiency particulate air (HEPA) vacuum and/or by wet wiping if necessary, and properly stored.

5. Isolate the work areas and create a directional airflow from other areas of the building into the work area. Turn the work area into a negative pressure enclosure by constructing isolation barriers and exhausting air from the work area to the outside through negative air machines equipped with HEPA filtration. Ensure that any gaps between the work area and the other areas of the base building have been sealed. This is to ensure that fungal spores and dust from the construction does not migrate to other areas of the building during the cleanup activity.

6. Ensure that any supply and return air grills located in the work area are isolated from the work area.

7. Remove the materials that are contaminated or likely contaminated with fungal growth at each location where water damage is determined to exist.

7.1. Remove the interior wallboard walls to a height of 4 feet at locations as depicted in the attached location sketch. This will include drywall and any existing wall insulation.

7.2. In all circumstances, removal of drywall and insulation shall be at least 2 feet beyond where visible fungal growth is observed.

7.3. Dust suppression methods, such as misting (not soaking) surfaces prior to remediation, are recommended.

8. Thoroughly clean all surfaces that remain within the enclosed area. Following the removal of all visible fungal growth with a HEPA vacuum, all surfaces shall be cleaned with a damp cloth, hard brush and a detergent solution.

9. Materials to be removed shall be taken from the work area sealed in a minimum of 6-mil plastic.

10. As the removal of fungal growth from semi-porous surfaces is a difficult task, coat any semi-porous surfaces (unfinished drywall in wall cavities) that remain within the work area with a fungal protective coating.

11. Upon completion, all areas within the work area should be dry and visibly free of fungal contamination, dust, and debris.

12. A visual inspection of the work area coupled with air sampling will be used to determine if the fungal growth remediation has been successful prior to the start of re-construction activities. Gandalf Associates, Inc. can conduct this interim inspection once all of the required remediation work has been completed, and the contained area has not been disturbed for at least 24 hours.

13. Following any remediation activity, visual inspections should be conducted at appropriate intervals to ensure that completed corrective actions have eliminated the cause of the fungal growth.

In addition to the above procedures, documentation (i.e. checklists) should be maintained on a daily basis for the following:

Engineering controls such as critical barriers and containment, are being properly maintained;

Safety and security of the site and site conditions are verified;

Any potential fire and/or health hazards are properly managed;

Proper fungal growth remediation procedures are being followed to ensure that materials are being removed in a way that prevents the emission of fungi and dust contaminated with fungi from leaving the work area, and that workers performing the remediation activities use appropriate personal protective equipment.

Appendix D – Identified Mold Locations

LOCATION SKETCH

Section b

Types of biocides and fungicidal agents

Fiberlock Shockwave:

Shockwave is an EPA-registered disinfectant, sanitizer and cleaner designed for use on various surfaces subject to microbial contamination, ideal for flooding and mold remediation

Omnipro On&Gone:

OMNIPRO ON&GONE 4L is a mold stain remover mad of a proprietary blend of sodium hypochlorite and surfactants. Designed to maximize dwell time and penetration into substrate

See product Data section for SDS information on both products

Product Description

Application Information

Product data Sheet

Properties Product Specifications

Active Ingredient: Quaternary Ammonium Chloride Color: Clear Blue Odor: Fresh Linen Foam: 0 Flash Point: >200ºF pH: 11.7 Shelf Life: 36 Months Min.

(Original Sealed Container)

Testing EPA Registration Number: 61178-1-73884 EPA Est. Number: 8325-PA-01

Available Package Sizes 10 oz. bottles (24/case) 1 gallon containers (4/case)

ShockWave™ Disinfectant/Sanitizer/Cleaner/Fungicide

ShockWave is an EPA registered disinfectant, sanitizer and cleaner designed specifically for mold remediation contractors. ShockWave is designed to meet all your disinfecting, sanitizing, cleaning, and de-odorizing needs. ShockWave is strong enough to be used in a hospital or medical environment, and has been specifically formulated to be used on both porous and non-porous materials. ShockWave is a powerful concentrated quaternary ammonium chloride blend that yields up to 64 gallons of usable product from every gallon of concentrate.

ShockWave has over 130 organism kill claims including Aspergillus niger, Penecillium spinulosum, E. coli, Salmonella, HIV, Hepatitis-B, Herpes, Poliovirus, and many other pathogenic and environmental microbial organisms.

8310/8311

DIRECTIONS

WATER DAMAGE RESTORATION: This product is particularly suitable for use in water damage restoration situations to sanitize against odor causing bacteria on the following porous and semi-porous materials: carpets, carpet cushion, subfloors, drywall, trim and frame lumber, tackless strip and paneling. Using solutions recommended, saturate affected materials with enough product to remain wet for at least 10 minutes.

SEWER BACKUP & RIVER FLOODING: During mitigation procedures, dilute 2-4 ounces of the product per gallon of water allowing for the diluting effect of absorbed water within saturated materials. Remove gross filth or heavy soil along with non-salvageable materials. Saturate all affected areas with a sprayer using a coarse spray tip, before and after cleaning and extraction.

Disinfection: Add two ounces of ShockWave per gallon of water. Remove gross filth or heavy soil. For heavily soiled areas, a pre-cleaning step is required. Apply solution with a cloth, mop, sponge, or hand pump trigger sprayer such that all surfaces remain wet for 10 minutes. Let air dry. Prepare a fresh solution for each use. ShockWave is effective in hard water up to 300 ppm hardness (calculated as CaCo3) and in the presence of organic soil (5% blood serum).

Fungicide: At 2 oz. per gallon, ShockWave is effective against the pathogenic fungi, Trichophyton mentagrophytes in 5% organic soil. Contact time - 10 minutes.

Virucidal: When used on inanimate, hard, non-porous, environmental surfaces at 2 ounces per gallon of water for a 10 minute contact time (5% organic soil), except for

Poliovirus type 1 (strain): which requires a 20 minute contact time (5% organic soil) and HIV-1 which requires only a 30 second contact time.

Cleaning and Deodorization: ShockWave deodorizes garbage storage areas, empty garbage bins and cans, toilet bowls and any other odor-causing areas. Mix 2 ounces per gallon of water and apply solution to surfaces. Be sure to thoroughly wet surfaces, allow to air dry.

CAUTION!

KEEP OUT OF REACH OF CHILDREN.

Do not take internally.

Close container after each use.

Keep from freezing.

Store in a dry place at temperatures between 40°F (4.5°C) and 90°F (32°C).

24 hour Emergency “CHEM-TEL” -

800.255.3924

FIRST AID

Skin: Remove contaminated clothing.

Flush affected areas with large quantities of water. Seek medical attention if irritation persists.

Eyes: Flush with large quantities of water, holding eyelids open. Seek medical attention.

Inhalation: Remove victim to fresh air and monitor. Seek medical attention if symptoms persist.

Ingestion: Give large quantities of water.

Seek medical attention immediately.

ShockWaveRTU contributes toward satisfying IEQ Credit 3.3 under LEED- EB by complying with “California Code ofRegulations maximum allowable VOClevels for disinfectants”.

Application Information

ShockWave™ Disinfectant/Sanitizer/Cleaner/Fungicide 8310/8311

For Technical Information call 800.342.3755 These suggestions and data are based on information we believe to be reliable. They are offered in good faith, but without guarantee, as conditions and methods of use of this product are beyond our control. Neither Fiberlock Technologies, Inc., nor its agents shall be responsible for the use or results of use of this product or any injury, loss or damage, direct or consequential. We recommend that the prospective user determine the suitability of this product for each specific project and for the health and safety of personnel working in the area.

ShockWave™, the ShockWave™ Logo and other marks in this literature are trademarks of Fiberlock Technologies, Inc.

Product data Sheet

Fiberlock Products and CPVC Compatibility Manufacturers of chlorinated polyvinyl chloride (“CPVC”) pipe believe that it can be sensitive to or incompatible with chemicals found in many commonly used household and industrial cleaning products, coatings, adhesives and other compounds, and that those chemicals can cause stress cracks or pipe failure. Fiberlock recommends that users always check pipe for markings that indicate the type of material it is made of and that users contact the pipe manufacturer directly before applying any Fiberlock products to CPVC pipe.

Note: The hazard category numbers found in GHS classification in section 2 of this SDSs are NOT to be used to fill in the NFPA 704 diamond. Blue = Health Red = Fire Yellow = Reactivity White = Special (Oxidizer or water reactive substances)

Fiberlock ShockWave 8310 ICP Building Solutions Group / Fiberlock Version No: 7.8 Safety Data Sheet according to OSHA HazCom Standard (2012) requirements

Issue Date: 08/26/2020 Print Date: 08/26/2020

S.GHS.USA.EN

SECTION 1 Identification

Product Identifier

Product name Fiberlock ShockWave 8310

Synonyms Not Available

Other means of identification Not Available

Recommended use of the chemical and restrictions on use

Relevant identified uses Disinfectant, Virucide, Fungicide

Name, address, and telephone number of the chemical manufacturer, importer, or other responsible party

Registered company name ICP Building Solutions Group / Fiberlock

Address 150 Dascomb Road Andover MA United States

Telephone 978 623 9980|866 667 5119

Fax Not Available

Website

Email sds@icpgroup.com

Emergency phone number

Association / Organisation ChemTel

Emergency telephone numbers

800-255-3924

Other emergency telephone numbers

813-248-0585

SECTION 2 Hazard(s) identification

Classification of the substance or mixture

Classification Skin Corrosion/Irritation Category 1C, Acute Aquatic Hazard Category 1, Serious Eye Damage Category 1, Acute Toxicity (Oral) Category 4, Skin Sensitizer Category 1, Chronic Aquatic Hazard Category 3

Label elements

Hazard pictogram(s)

Signal word Danger

Hazard statement(s)

H314 Causes severe skin burns and eye damage.

H400 Very toxic to aquatic life.

H302 Harmful if swallowed.

H317 May cause an allergic skin reaction.

H412 Harmful to aquatic life with long lasting effects.

www.icpgroup.com

Page 1 continued...

CAS No %[weight] Name

Hazard(s) not otherwise classified

Not Applicable

Precautionary statement(s) Prevention

P260 Do not breathe mist/vapours/spray.

P280 Wear protective gloves/protective clothing/eye protection/face protection.

P270 Do not eat, drink or smoke when using this product.

Precautionary statement(s) Response

P301+P330+P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.

P303+P361+P353 IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower.

P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Precautionary statement(s) Storage

P405 Store locked up.

Precautionary statement(s) Disposal

P501 Dispose of contents/container to authorised hazardous or special waste collection point in accordance with any local regulation.

SECTION 3 Composition / information on ingredients

Substances

See section below for composition of Mixtures

Mixtures

68391-01-5 2.37

68956-79-6 2.37

64-02-8 0-5

497-19-8 0-5

84133-50-6 0-5

7732-18-5 85-95

SECTION 4 First-aid measures

Description of first aid measures

Eye Contact

If this product comes in contact with the eyes:

Immediately hold eyelids apart and flush the eye continuously with running water.

Ensure complete irrigation of the eye by keeping eyelids apart and away from eye and moving the eyelids by occasionally lifting the upper and lower lids.

Continue flushing until advised to stop by the Poisons Information Centre or a doctor, or for at least 15 minutes.

Transport to hospital or doctor without delay.

Removal of contact lenses after an eye injury should only be undertaken by skilled personnel.

Skin Contact

If skin or hair contact occurs:

Immediately flush body and clothes with large amounts of water, using safety shower if available.

Quickly remove all contaminated clothing, including footwear.

Wash skin and hair with running water. Continue flushing with water until advised to stop by the Poisons Information Centre.

Transport to hospital, or doctor.

Inhalation

If fumes or combustion products are inhaled remove from contaminated area.

Lay patient down. Keep warm and rested.

Prostheses such as false teeth, which may block airway, should be removed, where possible, prior to initiating first aid procedures.

Apply artificial respiration if not breathing, preferably with a demand valve resuscitator, bag-valve mask device, or pocket mask as trained.

Perform CPR if necessary.

Transport to hospital, or doctor, without delay.

Ingestion

For advice, contact a Poisons Information Centre or a doctor at once.

Urgent hospital treatment is likely to be needed.

If swallowed do NOT induce vomiting.

If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain open airway and prevent aspiration.

Observe the patient carefully.

Never give liquid to a person showing signs of being sleepy or with reduced awareness; i.e. becoming unconscious.

Give water to rinse out mouth, then provide liquid slowly and as much as casualty can comfortably drink.

Transport to hospital or doctor without delay.

Most important symptoms and effects, both acute and delayed

See Section 11

Indication of any immediate medical attention and special treatment needed benzyl-C12-18-alkyldimethylammonium chloride

(C12-18)alkyldimethyl(ethylbenzyl)ammonium chloride

EDTA tetrasodium salt sodium carbonate alcohols C12-14 secondary ethoxylated water

Version No: 7.8 Page 2 of 10

Fiberlock ShockWave 8310

Issue Date: 08/26/2020

Print Date: 08/26/2020

Continued...

Treat symptomatically.

SECTION 5 Fire-fighting measures

Extinguishing media

The product contains a substantial proportion of water, therefore there are no restrictions on the type of extinguishing media which may be used. Choice of extinguishing media should take into account surrounding areas.

Though the material is non-combustible, evaporation of water from the mixture, caused by the heat of nearby fire, may produce floating layers of combustible substances.

Special hazards arising from the substrate or mixture

Fire Incompatibility None known.

Special protective equipment and precautions for fire-fighters

Fire Fighting Alert Fire Brigade and tell them location and nature of hazard.

Wear breathing apparatus plus protective gloves in the event of a fire.

Prevent, by any means available, spillage from entering drains or water courses.

Fire/Explosion Hazard

The material is not readily combustible under normal conditions.

However, it will break down under fire conditions and the organic component may burn.

Not considered to be a significant fire risk.

Decomposes on heating and produces toxic fumes of:

carbon dioxide (CO2) other pyrolysis products typical of burning organic material.

May emit poisonous fumes.

May emit corrosive fumes.

SECTION 6 Accidental release measures

Personal precautions, protective equipment and emergency procedures

See section 8

Environmental precautions

See section 12

Methods and material for containment and cleaning up

Minor Spills

Environmental hazard - contain spillage.

Clean up all spills immediately.

Avoid breathing vapours and contact with skin and eyes.

Control personal contact with the substance, by using protective equipment.

Major Spills

Environmental hazard - contain spillage.

Moderate hazard.

Clear area of personnel and move upwind.

Alert Fire Brigade and tell them location and nature of hazard.

Personal Protective Equipment advice is contained in Section 8 of the SDS.

SECTION 7 Handling and storage

Precautions for safe handling

Safe handling

Avoid all personal contact, including inhalation.

Wear protective clothing when risk of exposure occurs.

Use in a well-ventilated area.

DO NOT allow clothing wet with material to stay in contact with skin

Other information

Conditions for safe storage, including any incompatibilities

Suitable container Polyethylene or polypropylene container.

Packing as recommended by manufacturer.

Check all containers are clearly labelled and free from leaks.

Storage incompatibility None known

SECTION 8 Exposure controls / personal protection

Control parameters

Occupational Exposure Limits (OEL)

INGREDIENT DATA

Not Available

Version No: 7.8 Page 3 of 10

Fiberlock ShockWave 8310

Issue Date: 08/26/2020

Ingredient Material name TEEL-1 TEEL-2 TEEL-3

Ingredient Original IDLH Revised IDLH

Ingredient Occupational Exposure Band Rating Occupational Exposure Band Limit

Notes: Occupational exposure banding is a process of assigning chemicals into specific categories or bands based on a chemical's potency and the adverse health outcomes associated with exposure. The output of this process is an occupational exposure band (OEB), which corresponds to a range of exposure concentrations that are expected to protect worker health.

Emergency Limits benzyl-C12-18-alkyldimethylammonium chloride

Alkylbenzyldimethyl ammonium chloride, (C12-C18) 0.61 mg/m3 6.8 mg/m3 60 mg/m3

EDTA tetrasodium salt Ethylenediaminetetraacetic acid, tetrasodium salt, dihydrate 82 mg/m3 900 mg/m3 5,500 mg/m3

EDTA tetrasodium salt Ethylenediaminetetraacetic acid, tetrasodiumn salt; (Tetrasodium EDTA) 75 mg/m3 830 mg/m3 5,000 mg/m3 sodium carbonate Sodium carbonate 7.6 mg/m3 83 mg/m3 500 mg/m3 benzyl-C12-18-alkyldimethylammonium chloride

Not Available Not Available

(C12-18)alkyldimethyl(ethylbenzyl)ammonium chloride

Not Available Not Available

EDTA tetrasodium salt Not Available Not Available sodium carbonate Not Available Not Available alcohols C12-14 secondary ethoxylated Not Available Not Available water Not Available Not Available

Occupational Exposure Banding benzyl-C12-18-alkyldimethylammonium chloride

E ≤ 0.01 mg/m³

EDTA tetrasodium salt E ≤ 0.01 mg/m³ sodium carbonate E ≤ 0.01 mg/m³

Exposure controls

Appropriate engineering controls

Engineering controls are used to remove a hazard or place a barrier between the worker and the hazard. Well-designed engineering controls can be highly effective in protecting workers and will typically be independent of worker interactions to provide this high level of protection.

The basic types of engineering controls are:

Process controls which involve changing the way a job activity or process is done to reduce the risk.

Personal protection

Eye and face protection Chemical goggles.

Full face shield may be required for supplementary but never for primary protection of eyes.

Contact lenses may pose a special hazard; soft contact lenses may absorb and concentrate irritants.

Skin protection See Hand protection below

Hands/feet protection

Wear chemical protective gloves, e.g. PVC.

Wear safety footwear or safety gumboots, e.g. Rubber When handling corrosive liquids, wear trousers or overalls outside of boots, to avoid spills entering boots.

NOTE:

The material may produce skin sensitisation in predisposed individuals. Care must be taken, when removing gloves and other protective equipment, to avoid all possible skin contact.

Contaminated leather items, such as shoes, belts and watch-bands should be removed and destroyed.

The selection of suitable gloves does not only depend on the material, but also on further marks of quality which vary from manufacturer to manufacturer. Where the chemical is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application.

The exact break through time for substances has to be obtained from the manufacturer of the protective gloves and has to be observed when making a final choice.

Body protection See Other protection below

Other protection Overalls.

P.V.C apron.

Barrier cream.

Respiratory protection

Type A Filter of sufficient capacity. (AS/NZS 1716 & 1715, EN 143:2000 & 149:2001, ANSI Z88 or national equivalent)

Cartridge respirators should never be used for emergency ingress or in areas of unknown vapour concentrations or oxygen content.

The wearer must be warned to leave the contaminated area immediately on detecting any odours through the respirator. The odour may indicate that the mask is not functioning properly, that the vapour concentration is too high, or that the mask is not properly fitted. Because of these limitations, only restricted use of cartridge respirators is considered appropriate.

Cartridge performance is affected by humidity. Cartridges should be changed after 2 hr of continuous use unless it is determined that the humidity is less than 75%, in which case, cartridges can be used for 4 hr. Used cartridges should be discarded daily, regardless of the length of time used

SECTION 9 Physical and chemical properties

Version No: 7.8 Page 4 of 10

Fiberlock ShockWave 8310

Issue Date: 08/26/2020

Information on basic physical and chemical properties

Appearance Text

Physical state Liquid Relative density (Water = 1) Not Available

Odour Not Available Partition coefficient n-octanol

/ water Not Available

Odour threshold Not Available Auto-ignition temperature (°C) Not Available pH (as supplied) 11.0-12.0 Decomposition temperature Not Available

Melting point / freezing point (°C)

Not Available Viscosity (cSt) Not Available

Initial boiling point and boiling range (°C)

Not Available Molecular weight (g/mol) Not Available

Flash point (°C) Not Available Taste Not Available

Evaporation rate Not Available Explosive properties Not Available

Flammability Not Available Oxidising properties Not Available

Upper Explosive Limit (%) Not Available Surface Tension (dyn/cm or mN/m) Not Available

Lower Explosive Limit (%) Not Available Volatile Component (%vol) Not Available

Vapour pressure (kPa) Not Available Gas group Not Available

Solubility in water Immiscible pH as a solution (1%) Not Available

Vapour density (Air = 1) Not Available VOC g/L Not Available

SECTION 10 Stability and reactivity

Reactivity See section 7

Chemical stability Unstable in the presence of incompatible materials.

Product is considered stable.

Hazardous polymerisation will not occur.

Possibility of hazardous reactions

See section 7

Conditions to avoid See section 7

Incompatible materials

See section 7.Fiberlock Products and CPVC Compatibility: Manufacturers of chlorinated polyvinyl chloride (CPVC) pipe believe that it can be sensitive to or incompatible with chemicals found in many commonly used household and industrial cleaning products, coatings, adhesives and other compounds, and that those chemicals can cause stress cracks or pipe failure. Fiberlock recommends that users contact the pipe manufacturer directly before applying any Fiberlock products to the CPVC pipe.

Hazardous decomposition products

See section 5

SECTION 11 Toxicological information

Information on toxicological effects

Inhaled

The material can cause respiratory irritation in some persons. The body's response to such irritation can cause further lung damage.

Not normally a hazard due to non-volatile nature of product The material has NOT been classified by EC Directives or other classification systems as 'harmful by inhalation'. This is because of the lack of corroborating animal or human evidence.

Ingestion The material can produce chemical burns within the oral cavity and gastrointestinal tract following ingestion.

The material has NOT been classified by EC Directives or other classification systems as 'harmful by ingestion'. This is because of the lack of corroborating animal or human evidence.

Skin Contact

The material can produce chemical burns following direct contact with the skin.

Skin contact is not thought to have harmful health effects (as classified under EC Directives); the material may still produce health damage following entry through wounds, lesions or abrasions.

Open cuts, abraded or irritated skin should not be exposed to this material Entry into the blood-stream, through, for example, cuts, abrasions or lesions, may produce systemic injury with harmful effects. Examine the skin prior to the use of the material and ensure that any external damage is suitably protected.

Eye The material can produce chemical burns to the eye following direct contact. Vapours or mists may be extremely irritating.

If applied to the eyes, this material causes severe eye damage.

Chronic

Repeated or prolonged exposure to corrosives may result in the erosion of teeth, inflammatory and ulcerative changes in the mouth and necrosis (rarely) of the jaw. Bronchial irritation, with cough, and frequent attacks of bronchial pneumonia may ensue.

Long-term exposure to respiratory irritants may result in airways disease, involving difficulty breathing and related whole-body problems.

Skin contact with the material is more likely to cause a sensitisation reaction in some persons compared to the general population.

Substance accumulation, in the human body, may occur and may cause some concern following repeated or long-term occupational exposure.

Fiberlock ShockWave 8310 TOXICITY IRRITATION

Version No: 7.8 Page 5 of 10

Fiberlock ShockWave 8310

Issue Date: 08/26/2020

Not Available Not Available benzyl-C12-18-alkyldimethylammonium chloride

TOXICITY IRRITATION

Oral (rat) LD50: 447 mg/kg[2] Not Available

Oral (rat) LD50: 650 mg/kg[2]

(C12-18)alkyldimethyl(ethylbenzyl)ammonium chloride

TOXICITY IRRITATION

Not Available Not Available

EDTA tetrasodium salt

TOXICITY IRRITATION

Oral (mouse) LD50: 30 mg/kg[2] Eyes (rabbit): 1.9 mg

Oral (rat) LD50: 1260 mg/kg[2] Eyes (rabbit):100 mg/24h-moderate

Oral (rat) LD50: 2000-2200 mg/kg[2] Skin (rabbit):500 mg/24h-moderate

Oral (rat) LD50: 630 mg/kg[2] sodium carbonate

TOXICITY IRRITATION

714 mg/kg[2] Eye (rabbit): 100 mg/24h moderate dermal (rat) LD50: >2000 mg/kg[2] Eye (rabbit): 100 mg/30s mild

Inhalation (guinea pig) LC50: 0.4 mg/l/2h[2] Eye (rabbit): 50 mg SEVERE

Inhalation (rat) LC50: 1.15 mg/l/2he[2] Eye: adverse effect observed (irritating)[1]

Oral (mouse) LD50: 6600 mg/kg[2] Skin (rabbit): 500 mg/24h mild

Oral (rat) LD50: =4090 mg/kg[2] Skin: no adverse effect observed (not irritating)[1]

Oral (rat) LD50: 2800 mg/kg[2] alcohols C12-14 secondary ethoxylated

TOXICITY IRRITATION

Not Available Not Available water

TOXICITY IRRITATION

Oral (rat) LD50: >90000 mg/kg[2] Not Available

Legend: 1. Value obtained from Europe ECHA Registered Substances - Acute toxicity 2.* Value obtained from manufacturer's SDS. Unless otherwise specified data extracted from RTECS - Register of Toxic Effect of chemical Substances

EDTA TETRASODIUM SALT

* Sigma Aldrich - for the dihydrate For ethylendiaminetetraacetic acid (EDTA) and its salts:

EDTA is a strong organic acid, with a high affinity for alkaline-earth ions (for example, calcium and magnesium) and heavy-metal ions (such as lad and mercury), resulting in highly stable chelate complexes. The ability of EDTA to complex is used commercially to either promote or inhibit chemical reactions, depending on application.

EDTA and its salts are expected to be absorbed by the lungs and the gastrointestinal tract; absorption through skin is unlikely. They cause mild skin irritation, and severe eye irritation.

SODIUM CARBONATE

For sodium carbonate:

Sodium carbonate has little potential for skin irritation, but is irritating to the eyes. Due to its alkaline properties, irritation of the airways is also possible.

There is no data available for animal studies regarding the repeated dose toxicity of sodium carbonate by any route.

There is no evidence that sodium carbonate causes whole-body effects under normal handling and use. Sodium carbonate does not reach the foetus or the reproductive organs, which shows that there is no risk for developmental or reproductive toxicity.

The material may cause skin irritation after prolonged or repeated exposure and may produce on contact skin redness, swelling, the production of vesicles, scaling and thickening of the skin.

ALCOHOLS C12-14 SECONDARY ETHOXYLATED

Polyethers (such as ethoxylated surfactants and polyethylene glycols) are highly susceptible to being oxidized in the air. They then form complex mixtures of oxidation products.

Animal testing reveals that whole the pure, non-oxidised surfactant is non-sensitizing, many of the oxidation products are sensitisers. The oxidization products also cause irritation.

Humans have regular contact with alcohol ethoxylates through a variety of industrial and consumer products such as soaps, detergents and other cleaning products. Exposure to these chemicals can occur through swallowing, inhalation, or contact with the skin or eyes. Studies of acute toxicity show that relatively high volumes would have to occur to produce any toxic response.

Both laboratory and animal testing has shown that there is no evidence for alcohol ethoxylates (AEs) causing genetic damage, mutations or cancer. No adverse reproductive or developmental effects were observed.

Tri-ethylene glycol ethers undergo enzymatic oxidation to toxic alkoxy acids. They may irritate the skin and the eyes. At high oral doses, they may cause depressed reflexes, flaccid muscle tone, breathing difficulty and coma.

Fiberlock ShockWave 8310 & BENZYL-C12-18-

ALKYLDIMETHYLAMMONIUM CHLORIDE &

(C12-18)ALKYLDIMETHYL(ETHYLBENZYL)AMMONIUM

CHLORIDE & EDTA TETRASODIUM SALT & SODIUM

CARBONATE

Asthma-like symptoms may continue for months or even years after exposure to the material ends. This may be due to a non-allergic condition known as reactive airways dysfunction syndrome (RADS) which can occur after exposure to high levels of highly irritating compound. Main criteria for diagnosing RADS include the absence of previous airways disease in a non-atopic individual, with sudden onset of persistent asthma-like symptoms within minutes to hours of a documented exposure to the irritant.

Version No: 7.8 Page 6 of 10

Fiberlock ShockWave 8310

Issue Date: 08/26/2020

Fiberlock ShockWave 8310 & EDTA TETRASODIUM

SALT

The following information refers to contact allergens as a group and may not be specific to this product.

Contact allergies quickly manifest themselves as contact eczema, more rarely as urticaria or Quincke's oedema. The pathogenesis of contact eczema involves a cell-mediated (T lymphocytes) immune reaction of the delayed type. Other allergic skin reactions, e.g. contact urticaria, involve antibody-mediated immune reactions.

BENZYL-C12-18-ALKYLDIMETHYLAMMONIUM

CHLORIDE &

(C12-18)ALKYLDIMETHYL(ETHYLBENZYL)AMMONIUM

CHLORIDE

The material may cause severe skin irritation after prolonged or repeated exposure and may produce on contact skin redness, swelling, the production of vesicles, scaling and thickening of the skin. Repeated exposures may produce severe ulceration.

Alkyldimethylbenzylammonium chlorides are in the list of dangerous substances of council directive, classified as 'harmful in contact with skin and on ingestion', and 'corrosive and very toxic to aquatic organisms'. It can cause dose dependent skin and eye irritation with possible deterioration of vision, possible sensitisation in those with pre-existing eczema. It does not cause cancer, genetic defect, foetal or developmental abnormality.

(C12-18)ALKYLDIMETHYL(ETHYLBENZYL)AMMONIUM

CHLORIDE & ALCOHOLS C12-14 SECONDARY

ETHOXYLATED & WATER

No significant acute toxicological data identified in literature search.

Acute Toxicity Carcinogenicity

Skin Irritation/Corrosion Reproductivity

Serious Eye Damage/Irritation STOT - Single Exposure

Respiratory or Skin sensitisation

STOT - Repeated Exposure

Mutagenicity Aspiration Hazard

Legend: – Data either not available or does not fill the criteria for classification

– Data available to make classification

SECTION 12 Ecological information

Toxicity

Fiberlock ShockWave 8310 Endpoint Test Duration (hr) Species Value Source

Not Available Not Available Not Available Not Available Not Available benzyl-C12-18-alkyldimethylammonium chloride

Endpoint Test Duration (hr) Species Value Source

Not Available Not Available Not Available Not Available Not Available

(C12-18)alkyldimethyl(ethylbenzyl)ammonium chloride

Endpoint Test Duration (hr) Species Value Source

Not Available Not Available Not Available Not Available Not Available

EDTA tetrasodium salt

Endpoint Test Duration (hr) Species Value Source

LC50 96 Fish 1-592mg/L 2

EC50 48 Crustacea 140mg/L 2

EC50 72 Algae or other aquatic plants =1.01mg/L 1

EC10 72 Algae or other aquatic plants =0.48mg/L 1

NOEC 72 Algae or other aquatic plants =0.39mg/L 1 sodium carbonate

Endpoint Test Duration (hr) Species Value Source

LC50 96 Fish 300mg/L 2

EC50 48 Crustacea 265mg/L 2

NOEC 96 Fish =550mg/L 1 alcohols C12-14 secondary ethoxylated Endpoint Test Duration (hr) Species Value Source

Not Available Not Available Not Available Not Available Not Available water Endpoint Test Duration (hr) Species Value Source

Not Available Not Available Not Available Not Available Not Available

Legend: Extracted from 1. IUCLID Toxicity Data 2. Europe ECHA Registered Substances - Ecotoxicological Information - Aquatic Toxicity 3. EPIWIN Suite V3.12 (QSAR) - Aquatic Toxicity Data (Estimated) 4. US EPA, Ecotox database - Aquatic Toxicity Data 5. ECETOC Aquatic Hazard Assessment Data 6. NITE (Japan) - Bioconcentration Data 7. METI (Japan) - Bioconcentration Data 8. Vendor Data

Very toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment.

Do NOT allow product to come in contact with surface waters or to intertidal areas below the mean high water mark. Do not contaminate water when cleaning equipment or disposing of equipment wash-waters.

Wastes resulting from use of the product must be disposed of on site or at approved waste sites.

DO NOT discharge into sewer or waterways.

Persistence and degradability

Version No: 7.8 Page 7 of 10

Fiberlock ShockWave 8310

Issue Date: 08/26/2020

Ingredient Persistence: Water/Soil Persistence: Air

Ingredient Bioaccumulation

Ingredient Mobility sodium carbonate LOW LOW water LOW LOW

Bioaccumulative potential sodium carbonate LOW (LogKOW = -0.4605) water LOW (LogKOW = -1.38)

Mobility in soil sodium carbonate HIGH (KOC = 1) water LOW (KOC = 14.3)

SECTION 13 Disposal considerations

Waste treatment methods

Product / Packaging disposal

Containers may still present a chemical hazard/ danger when empty.

Return to supplier for reuse/ recycling if possible.

Otherwise:

If container can not be cleaned sufficiently well to ensure that residuals do not remain or if the container cannot be used to store the same product, then puncture containers, to prevent re-use, and bury at an authorised landfill.

Legislation addressing waste disposal requirements may differ by country, state and/ or territory. Each user must refer to laws operating in their area. In some areas, certain wastes must be tracked.

DO NOT allow wash water from cleaning or process equipment to enter drains.

It may be necessary to collect all wash water for treatment before disposal.

In all cases disposal to sewer may be subject to local laws and regulations and these should be considered first.

Recycle wherever possible.

Consult manufacturer for recycling options or consult local or regional waste management authority for disposal if no suitable treatment or disposal facility can be identified.

Dispose of by: burial in a land-fill specifically licensed to accept chemical and / or pharmaceutical wastes or incineration in a licensed apparatus (after admixture with suitable combustible material).

SECTION 14 Transport information

Labels Required

Marine Pollutant

Land transport (DOT): NOT REGULATED FOR TRANSPORT OF DANGEROUS GOODS

Air transport (ICAO-IATA / DGR): NOT REGULATED FOR TRANSPORT OF DANGEROUS GOODS

Sea transport (IMDG-Code / GGVSee): NOT REGULATED FOR TRANSPORT OF DANGEROUS GOODS

Transport in bulk according to Annex II of MARPOL and the IBC code

Not Applicable

SECTION 15 Regulatory information

Safety, health and environmental regulations / legislation specific for the substance or mixture benzyl-C12-18-alkyldimethylammonium chloride is found on the following regulatory lists

US DOE Temporary Emergency Exposure Limits (TEELs)

US Toxic Substances Control Act (TSCA) - Chemical Substance Inventory

US TSCA Chemical Substance Inventory - Interim List of Active Substances

(C12-18)alkyldimethyl(ethylbenzyl)ammonium chloride is found on the…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .