Attachment_I_-_IBT_Bus_Terminal_-_Floor_Plan.pdf
PDF 549 KB Posted
- Attached to
- Janitorial Services
- Solicitation number
- P-24-026
- Issued by
- Duval County, Jacksonville City, Florida
About this file
The document is an architectural floor plan for an Intercity Bus Terminal located at 1111 Forsyth St. W. in Jacksonville, Florida, prepared by Pond & Michael Baker International for the Jacksonville Transportation Authority (JTA). The floor plan details a comprehensive layout of a bus terminal facility, including various functional spaces such as food service areas, administrative offices, ticket counters, waiting areas, restrooms, driver lounges, and support spaces like storage rooms, electrical/data rooms, and vestibules. The plan includes precise dimensional measurements, room numbering, and notes regarding partition types, finished floor elevations, and contractor verification requirements.
The floor plan drawing is part of a permit set dated January 27, 2017, with subsequent revisions on April 12 and April 28, 2017. The document includes specific technical notes for contractors, such as verification of dimensions, interior door jamb specifications, and requirements for wood blocking and signage. The plan shows both a main floor plan and an elevated walkway plan, indicating a multi-level design with future provisions for pedestrian bridges. The drawing is marked as complying with Buy America Provisions and includes detailed wall legends distinguishing between stud and CMU (concrete masonry unit) walls, providing a comprehensive architectural blueprint for the bus terminal's construction.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
D
C
A
FOOD SERVICE
FOOD
PREPARATION
ADMIN
TERMINAL
MANAGER
OPS/DRIVER
MANAGER
GPX
DRIVER
LOUNGE
BREAKROOM
TICKET
COUNTER
VENDING &
FOOD SERVICE
TICKET
QUEUING
DEPARTURE
QUEUING
WOMEN'S
MEN'S
WAITING AREA
14 13
OFFICE
DRY STORAGE
COOLER AREA
ELEC./DATA
ROOM
VESTIBULE
JANITOR
VESTIBULE
RECORDS
STORAGE
CASH ROOM
PARTITION FROM FLOOR TO
UNDERSIDE OF MAINFRAME
STRUCTURE ABOVE
CHAIN LINK FENCE
ENCLOSURE WITH
GATE.
WAITING AREA SEATING
(PROVIDED BY GREYHOUND)
HIGH-LOW ADA
ACCESSIBLE
FOUNTAIN - CANE
APRON
PAYPHONE 48" AFF
(BY OTHERS)GREASE
INTERCEPTOR
A-400
C4 A-401
C5
A-201
B5 B5
A-301
B5
A-301
A-202
B5
A-202
C5
A-201
D5
A-201
C5
D3
A-352
D4
A-352
D4
A-351
D5
A-351
D2
A-352
D5
A-301
D5
A-301
87654321
23 20 17 16 10
A.5
B5
A-302
B5
A-302
D5
A-352
A-603
C5
B2
B2
B2
A-406
B5
D
183' - 8"
D5
A-302
D5
A-302
A-403
B5
BOLLARDS
SEE CIVIL DWGS
FOR LOCATIONS
WALK OFF MAT
WALK OFF MAT
8' - 0"
13' - 0"
1' - 4" 25' - 0" 25' - 0" 25' - 0" 25' - 0" 25' - 0" 25' - 0" 31' - 0" 1' - 4"
2' - 11" 52' - 3 3/4" 41' - 1 1/2" 6' - 8 1/2" 6' - 7 5/8" 8' - 2 1/2" 14' - 11 7/8" 13' - 4" 16' - 8" 6' - 8" 6' - 8" 7' - 5 1/4"
1' - 10" 109' - 10" 13' - 10" 27' - 8" 31' - 0"
184' - 2"
CANOPY
ABOVE
ADA RAMP
C
CANOPY
ABOVE
CANOPY
ABOVE
ACCENT BANDING
ABOVE
EXTERIOR DIMENSIONS TO FACE
OF INSULATED METAL PANEL
B
STORAGE
VENDING
STORAGE
FIRE RISER
7' - 0"
FE
FEC-1
FEC-2
FEC-1
8' - 0"
AUTOMATIC OPENING
ADA ACCESSIBLE DOOR
MANUAL OPENING DOOR
CANOPY
ABOVE
01A01
FEC-1
6"
9' - 0"
SEE L-501 FOR
DETAILS
ROOF LADDER
WITH CAGED1
A-151
UP
UP
UP FUTURE
BRIDGE PIER
D
C
B5
A-301
B5
A-301
A-201
C5
D5
A-301
D5
A-301 87654321
A-603
C5
A-407
C5
A-408
B5
CANOPY
ABOVE
DN FUTURE
PEDESTRIAN
BRIDGE
CANOPY
ABOVE
18' - 0"
D3
A-801
1. PARTITIONS SHALL BE TYPE "A" (NO SUBSCRIPT) UNLESS
OTHERWISE INDICATED
2. FINISHED FLOOR ELEVATION REFERENCED AT 0'-0" IS A
DATUM EQUAL TO CIVIL ELEVATION 17.42
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE
FIELD. CONTRACTOR TO NOTIFY ARCHITECT/ENGINEER
IMMEDIATELY OF ANY DISCREPENCIES
4. ALL DIMENSIONS ARE TO THE STUD UNLESS NOTED
OTHERWISE
5. ALL INTERIOR DOOR JAMBS SHALL BE 4" FROM WALL TO
OUTSIDE FACE OF JAMB UNLESS NOTED OTHERWISE.
6. FOR FINISHES, SEE A-901
7. PROVIDE WOOD BLOCKING AS REQUIRED BEHIND
GYPSUM BOARD TO SECURE ATTACHMENT OF ALL
FIXTURES, FITTINGS, CASEWORK, DOOR STOPS AND
ACCESSORIES
8. ALL WORK SHALL BE IN ACCORDANCE WITH
MANUFACTURERS LATEST STANDARD RECOMMENDATIONS
AND APPLICABLE CODES
9. ALL INTERIOR SIGNAGE TO BE PROVIDED AND INSTALLED
BY GREYHOUND VENDOR, UNDER SEPARATE CONTRACT,
AND SHALL BE ADA COMPLIANT
FLOOR PLAN NOTES:
WALL LEGEND
STUD WALLS
CMU WALLS
STUD WALLS - TO UNDERSIDE OF
MAINFRAME STRUCTURE
D DRAWN BY:
REVISION
C
B
A
5 4 3 2 1
JACKSONVILLE
TRANSPORTATION
AUTHORITY
POND & COMPANY
LICENSE NO. AA26001253
POND COA: 8085
10199 SOUTHSIDE BOULEVARD, SUITE 103
JACKSONVILLE, FL 32256
P: (904) 543-0400 F: (904) 543-0203
POND PROJ. NO.
DATE:
DATENO.
MICHAEL BAKER INTERNATIONAL
LICENSE NO. AA26002484
MBI COA: 829243
12740 GRAN BAY PKWY WEST, SUITE 2110
JACKSONVILLE, FL 32258
P: (904) 380-2500
Copyright © 2017 by Pond | Michael Baker International. All rights reserved. No copying or duplication of these documents is allowed without the express written agreement of Pond | Michael Baker International.
DESIGNED BY:
CHECKED BY:
MBI PROJ. NO.
PROJECT REQUIRES DOCUMENTATION OF
COMPLIANCE WITH SPECIFICATION
SECTION 001010 BUY AMERICA PROVISIONS
/2
/2
:3 :4
P
M A
/1
J
T A
J R
T C
/1
IB
T A
R C
H C
E N
T R
A L R
.r v t
A-101
Author
PERMIT SET
INTERCITY BUS
TERMINAL
1111 FORSYTH ST. W.
JACKSONVILLE, FL
1160576
FLOOR PLANS
01/27/2017
Designer
Checker
155641
SCALE: 1/8" = 1'-0"B2
FLOOR PLAN
N
SCALE: 1" =
0 60 12060
60' - 0"
SCALE: 1/8" = 1'-0"C2
ELEVATED WALKWAY PLAN
N
DRAWING REVISIONS
2 04/28/2017 OWNER DIRECTED
REVISIONS
1 04/12/2017 COJ COMMENTS
carom Snapshot
File details come from the government source that posted it. Updated .