Attachment I - Combined Equipment List for Sources Sought.xlsx

XLSX spreadsheet 31 KB Posted

Attached to
Thermo Fisher Scientific Maintenance Services
Solicitation number
NIST-MML-25-SS26
Issued by

About this file

This document is an Attachment I - Combined Equipment List for a Sources Sought Notice for Thermo Fisher Scientific Maintenance Services issued by the National Institute of Standards and Technology (NIST) Material Measurement Laboratory. The comprehensive spreadsheet details 85+ scientific instruments across multiple divisions (645, 646, 643), including liquid chromatography systems, mass spectrometers, freezers, genetic sequencing equipment, and other specialized laboratory instruments located primarily in Gaithersburg, MD, with a few items in Charleston, SC.

The sources sought notice seeks a service agreement for maintenance and repair of these Thermo Fisher Scientific instruments, with specific requirements including full system performance guarantees, unlimited emergency visits, parts replacement, preventive maintenance, 3-business-day emergency response time, and technical support. NIST anticipates issuing a Request for Quotation in the fourth quarter of FY2025, with contract award by the same period. The procurement is open to all responsible sources, including small businesses, with a small business size standard of $34M under NAICS code 811210. Interested contractors must submit a 20-page response detailing company capabilities, previous experience, and relevant certifications by the specified response date.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DIVISION 645

TABLE 1 - DIVISION 645
Division.GroupTPOCInstrument NameModel NumberSerial NumberNIST CampusBuilding No.Room No.
645.00Pawel JarugaPumpDGP-3600RS8090588Gaithersburg, MD227A238
645.00Pawel JarugaAutosamplerWPS-3000TRS8090297Gaithersburg, MD227A238
645.00Pawel JarugaColumn CompartmentTCC-3000RS6001549Gaithersburg, MD227A238
645.00Pawel JarugaDetectorVWD-3400RS8100490Gaithersburg, MD227A238
645.00Pawel JarugaFraction CollectorAFC-3000031506AFC3000Gaithersburg, MD227A238
645.00Pawel JarugaThermo TSQ AltisN/ATSQ-A-10500Gaithersburg, MD227A242
645.00Pawel JarugaQuarternary Pump FVF-P20-A8312980Gaithersburg, MD227A242
645.00Pawel JarugaSplit Sampler FTVF-A10-A-028312964Gaithersburg, MD227A242
645.00Pawel JarugaColumn Compartment HVH-C10-A-026503220Gaithersburg, MD227A242
645.00Pawel JarugaDiode Array Detector FGVF-D11-A-018313195Gaithersburg, MD227A242
645.03Kat YandrofskiLC 1 PumpVF-P10-A8362469IBBR22229
645.03Kat YandrofskiLC 1 AutosamplerVF-A10-A8362311IBBR22229
645.03Kat YandrofskiLC 1 Column CompartmentVH-C10-A6522074IBBR22229
645.03Kat YandrofskiLC 1 Fluroescence DetectorVF-D50-A8356255IBBR22229
645.03Kat YandrofskiLC 1 Variable Wavelength DetectorVF-D40-A8354773IBBR22229
645.03Kat YandrofskiLC 1 Fraction CollectorVF-F20-A4200124IBBR22229
645.03Kat YandrofskiLC 2 PumpVF-P10-A8362173IBBR22229
645.03Kat YandrofskiLC 2 AutosamplerVF-A10-A8361963IBBR22229
645.03Kat YandrofskiLC 2 Column CompartmentVH-C10-A6522064IBBR22229
645.03Kat YandrofskiLC 2 Variable Wavelength DetectorVF-D40-A8354662IBBR22229
645.03Kat YandrofskiLC 2 Fraction CollectorVF-F20-A4200122IBBR22229
645.04Meghan Burke Harris2D LC PumpDPG-3600RS8079159Gaithersburg, MD221B359
645.04Meghan Burke Harris2D LC AutosamplerWPS-3000TFC8079384Gaithersburg, MD221B359
645.04Meghan Burke Harris2D LC Column Compartment 1TCC-3000RS8079734Gaithersburg, MD221B359
645.04Meghan Burke Harris2D LC Column Compartment 2TCC-3000RS8079739Gaithersburg, MD221B359
645.04Meghan Burke Harris2D LC UV DetectorVWD-3400RS8077845Gaithersburg, MD221B359
645.04Yuxue LiangOribtrap Elite MS Including ChillerLTQ-Orbitrap EliteSN03304BGaithersburg, MD221A324
645.04Yuxue LiangOrbitrap Elite ETD UpgradeLTQ-Orbitrap EliteETD10606Gaithersburg, MD221A324
645.04Yuxue LiangNano LC- Elite Nano PumpNCS-3500RS8177887Gaithersburg, MD221A324
645.04Yuxue LiangNano LC- Elite AutosamplerWPS-3000TPL8177787Gaithersburg, MD221A324
645.04Yuxue LiangNano LC- Old LUMOS Nano PumpNCS-3500RSDX8068748Gaithersburg, MD221A324
645.04Yuxue LiangNano LC- Old LUMOS AutosamplerWPS-3000TPLDX8070481Gaithersburg, MD221A324
645.04Yuxue LiangConventional LC- Old LUMOS PumpHPG-3400RS8105018Gaithersburg, MD221A324
645.04Yuxue LiangConventional LC- Old LUMOS Column CompartmentTCC3000RS6006098Gaithersburg, MD221A324
645.04Yuxue LiangConventional LC- Old LUMOS AutosamplerWPS3000RS8105204Gaithersburg, MD221A324
645.04Yuxue LiangOld Oritrap Fusion LUMOSOrbitrap Fusion LUMOSFSN20104Gaithersburg, MD221A324
PERFORMANCE MAINTENANCE MSPEC-LC-MSFSN20104
645.04Meghan Burke HarrisNew Orbitrap Fusion LUMOSOrbitrap Fusion LUMOSFSN20664Gaithersburg, MD221A322
PERFORMANCE MAINTENANCE MSPEC-LC-MSFSN20664
645.04Meghan Burke HarrisNano LC- New LUMOS PumpNCS-3500RS8161904Gaithersburg, MD221A322
645.04Meghan Burke HarrisNano LC- New LUMOS AutosamplerWPS-3000TPL8161317Gaithersburg, MD221A322
645.04Yuxue LiangMinus 80 Freezer 1TLE60086A1119902101190325Gaithersburg, MD221A324
645.04Yuxue LiangMinus 80 Freezer 2TLE60086A1119901701190325Gaithersburg, MD221A320
645.04Meghan Burke HarrisVanquish UHPLC Binary Pump FVF-P10-A-018331433Gaithersburg, MD221B359
645.04Meghan Burke HarrisVanquish UHPLC Split Sampler FTVF-A10-A-028332485Gaithersburg, MD221B359
645.04Meghan Burke HarrisVanquish Column CompartmentVH-C10-A6510347Gaithersburg, MD221B359
645.04Meghan Burke HarrisVanquish UHPLC Fluorescence Detector FVF-D51-A8332958Gaithersburg, MD221B359
645.06Kevin KieslerIon ChefIon Chefchef00748Gaithersburg, MD227B261
645.06Kevin KieslerABI 3500xlABI 3500xl24343-080Gaithersburg, MD227B257
645.06Kevin KieslerABI 7500 HIDABI 7500 HID275009404Gaithersburg, MD227B257
645.06Kevin KieslerABI 7500 HID (#2)ABI 7500 HID2750010927Gaithersburg, MD227B257
645.06Kevin KieslerIon Torrent S5XLIon Torrent S5XL245749700729Gaithersburg, MD227B261
645.06Kevin KieslerAbsolute QAbsolute Q2262721120167Gaithersburg, MD227B225
645.06Kevin KieslerRapid HIT IDRapid HIT IDRHID-0763Gaithersburg, MD227B257
645.07Kyle AndersonCold UPLC Binary Vanquish PumpVH-P10-A8302178IBBRBuilding 2Room 2229B
645.08Mark LowenthalFreezer/-80CFORMA 8607813063-572Gaithersburg, MD227B145
645.08Mark LowenthalPumpNCS-3500RSDX8062313Gaithersburg, MD227A144
645.08Mark LowenthalAutosamplerWPS-3000TPLRSDX8056604Gaithersburg, MD227A144
645.08Mark LowenthalUV/Vis Variable Wavelength DetectorVWD-3100DX8065067Gaithersburg, MD227A144
645.08Mark LowenthalOrbitrap Elite Mass Spectrometer Including ChillerORBITRAP ELITESN05183BGaithersburg, MD227A152
645.08Mark LowenthalETD Add-OnETDETD10810Gaithersburg, MD227A152
645.08Mark LowenthalHPG PumpHPG-3200RSDX8063178Gaithersburg, MD227A152
645.08Mark LowenthalWPS AutosamplerWPS-3000TRSDX8064795Gaithersburg, MD227A152
645.08Mark LowenthalTCC Column CompartmentTCC-3000RSDX8063678Gaithersburg, MD227A152
645.08Mark LowenthalVWD Variable Wavelength Detector (UV/Vis)VWD-3400RSDX8065460Gaithersburg, MD227A152
645.08Mark LowenthalFLD Fluorescence DetectorFLD-3400RS DUAL PMTDX8063036Gaithersburg, MD227A152
645.08Mark LowenthalQ-Exactive Mass SpectrometerQ-ExactiveSN01469LGaithersburg, MD227A152
645.08David BunkSavant SPD1030 SpeedVacSPD1030-1151154682801190919Gaithersburg, MD227A148
645.08Mark LowenthalHPG PumpHPG-3400RS8157302Gaithersburg, MD227A144
645.08Mark LowenthalAutosamplerWPS-3000TRS8159215Gaithersburg, MD227A144
645.08Mark LowenthalTCC Column CompartmentTCC-3000RS6022759Gaithersburg, MD227A144
645.08Mark LowenthalVariable wavelength detectorVWD-3400RS8158891Gaithersburg, MD227A144
645.08David BunkTSQ Altis Mass SpectrometerN/ATSQ-A-10718Gaithersburg, MD227A144
646.08David BunkTSQ Altis LC PumpBinary Pump C8321376Gaithersburg, MD227A144
647.08David BunkTSQ Altis SamplerSplit Sampler CT8321593Gaithersburg, MD227A144
648.08David BunkTSQ Altis Column CompartmentColumn Compartment C6506125Gaithersburg, MD227A144
645.08Kat YandrofskiFreezer/-80CTSU600D0148088301150911Gaithersburg, MD227A142
645.08Kat YandrofskiFreezer/-80CFORMA 900840127-1466Gaithersburg, MD227A130
645.08Trina MouchahoirPumpHPG-3400RS8080854IBBRCARBII2229
645.08Trina MouchahoirAutosamplerWPS-3000TBRS8078898IBBRCARBII2229
645.08Trina MouchahoirColumn CompartmentTCC-3000RS8080379IBBRCARBII2229
645.08Trina MouchahoirFluorescence DetectorFLD-3400RS8080732IBBRCARBII2229
645.08Trina MouchahoirUV DetectorVWD-3400RS8080910IBBRCARBII2229
645.08Trina MouchahoirFraction CollectorAFC-3000091307AFC3000IBBRCARBII2229
645.08Trina MouchahoirPumpHPG-3400RS8103117IBBRCARBII2229
645.08Trina MouchahoirAutosamplerWPS-3400TRS8103514IBBRCARBII2229
645.08Trina MouchahoirColumn CompartmentTCC-3000RS6005598IBBRCARBII2229
645.08Trina MouchahoirFluorescence DetectorFLD-3400RS8103456IBBRCARBII2229
645.08Trina MouchahoirUV DetectorVWD-3400RS8103555IBBRCARBII2229

DIVISION 646

TABLE 1 - DIVISION 646 & 643
Division.GroupTPOCInstrument NameModel NumberSerial NumberNIST CampusBuilding No.Room No.
646.01Neptune Multi-CollectorNeptune01062NGaithersburg, MDA120
646.01ChristopherElement XRSN04031ECharlston, SCHML
646.02Q-Exactive Mass SpectrometerQ ExactiveSN01464LGaithersburg, MDB159
646.02Fluorescence DetectorFLD-3400RS8025884Gaithersburg, MDA144
646.02Dual Gradient PumpDGP-3600RS8046729Gaithersburg, MDB159
646.02Autosampler/Fraction CollectorWPS-3000TFC8046599Gaithersburg, MDB159
646.02Autosampler/Fraction CollectorWPS-3000TFC8046599Gaithersburg, MDB159
646.02Diode Array DetectorDAD-3000RS8025570Gaithersburg, MDB159
646.02BENNERGC/MS/MS1Trace 1310/TSQ 8000 EVO- GC715101377Gaithersburg, MD
646.02BENNERGC/MS/MS1Trace 1310/TSQ 8000 EVO- MSTSQ8150931Gaithersburg, MD
646.02BENNERGC/MS/MS1Trace 1310/TSQ 8000 EVO- SSL Injector715300859Gaithersburg, MD
646.02BENNERGC/MS/MS1Trace 1310/TSQ 8000 EVO- PTV Injector715320246Gaithersburg, MD
646.02BENNERGC/MS/MS1Trace 1310/TSQ 8000 EVO- AUX temp Module715500124Gaithersburg, MD
646.02BENNERGC/MS/MS1Trace 1310/TSQ 8000 EVO- Triplus 110LS351323Gaithersburg, MD
646.02BENNERFREEZERREVCO UXF60086D0160043801160902Gaithersburg, MDA130
646.02WILSONFREEZERUXF60086A1160881001170616Gaithersburg, MDA130
646.02JONESFREEZERRLE60086A1119272901181001Gaithersburg, MDB155
646.02WILSONFREEZERTLE60086A1119900901190325Gaithersburg, MDA130
646.02JONESFREEZER8605808427-142Gaithersburg, MDA138
646.02CAMARAFREEZERTDE60086FA1154715401200403Gaithersburg, MDA334
646.11DAVISQ-Exactive OrbiTrap Mass SpectrometerQ-ExactiveSN10000LCharlston, SCHML
646.11NeelyOrbitrap Fusion Lumos ETDOrbitrap Fusion Lumos ETDFSN20268Charlston, SCHML
643Ruthmara CorzoThermo iCAP Qc ICP-MS02213RGaithersburg, MD217C121