This document contains a sources sought notice from the General Services Administration for an emergency generator and fire pump replacement project. The GSA Region 5 is seeking information from small businesses for replacing the existing diesel generator and fire pump with a new 500kW natural gas generator and fire pump at the Walter H. Rice Federal Building and U.S. Courthouse in Dayton, Ohio. The construction cost is estimated between $1,000,000 to $3,375,000 and the performance period will be 275 calendar days upon receipt of the notice to proceed. Interested firms should submit the market research questionnaire and project experience forms for a minimum of two similar projects completed in the last eight years exceeding $350,000 by July 21, 2022 to Lisa Gonzalez, Contracting Officer. Responses will be evaluated to determine the availability and adequacy of potential small business sources prior to a formal solicitation.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTRACTOR INFORMATION
FIRM NAME:
FIRM ADDRESS:
POINT OF CONTACT:
PHONE NUMBER:
EMAIL ADDRESS:
UNIQUE ENTITY ID (UEI):
TYPE OF BUSINESS
THE NORTH AMERICAN INDUSTRIAL CLASSIFICATION SYSTEM (NAICS) CODE FOR THIS POTENTIAL
PROJECT IS 236220 AND THE SBA SMALL BUSINESS SIZE STANDARD IS $39.5 MILLION. CHECK ALL THAT
APPLY BELOW:
SBA CERTIFIED 8(A)
SBA CERTIFIED HUBZONE
SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESS
WOMEN-OWNED SMALL BUSINESS
SMALL BUSINESS
OTHER
INTENT BID
DO YOU INTEND TO BID ON A SUBSEQUENT SOLICITATION?
YES
NO
EXPERIENCE
PRIMARY EXPERIENCE SERVING AS:
PRIME CONTRACTOR
SUBCONTRACTOR
YEARS THE FIRM HAS BEEN IN BUSINESS:
NUMBER OF EMPLOYEES:
DOES YOUR FIRM HAVE THE CAPABILITY TO SELF-PERFORM THE WORK WITH YOUR ON FORCES?
YES
NO
** PROVIDE A MINIMUM OF 2 SIMILAR PROJECTS THAT WERE SUBSTANTIALLY COMPLETED WITHIN THE LAST 8 YEARS. SIMILAR PROJECTS SHOULD BE COMPARABLE IN SIZE, SCOPE, AND COMPLEXITY.
COMPLETE THE PROJECT EXPERIENCE FORM FOR EACH EXAMPLE. **
MARKET RESEARCH QUESTIONNAIRE
1. PROJECT NAME & LOCATION
2. REFERENCE (Owner, Contact Person, Phone Number, Email Address)
3. INITIAL COST OF THE PROJECT 4. FINAL COST OF THE PROJECT
5. WAS THE PROJECT PERFORMED IN AN OCCUPIED BUILDING?
YES NO
6. SIZE OF PROJECT (Square Footage)
7A. IF COMPLETED PROJECT – COMPLETED
ON TIME? (If the project is not complete, skip 7 & go to 8)
YES NO (If no, explain on back)
7B. START DATE 7C. ACTUAL/FINAL
COMPLETION DATE
8A. IF CURRENT PROJECT – ON SCHEDULE?
YES NO (If no, explain on back)
8B. ESTIMATED COMPLETION
DATE
8C. PERCENT
COMPLETED
9. PROVIDE PROJECT DESCRIPTION:
10. PROBLEMS ENCOUNTERED AND CORRECTIVE ACTIONS TAKEN:
Please add a continuation page if additional space necessary.
PROJECT EXPERIENCE