Attachment E - Pricing Form.xlsx
XLSX spreadsheet 187 KB Posted
- Solicitation number
- RFB # 531569A / Project # CS-1998
- Issued by
- Wayne County, Michigan
About this file
The provided document is an Attachment E - Pricing Form for the Detroit Water and Sewerage Department (DWSD), detailing a Local Sewer System Metering and Condition Assessment project with the project number CS-1998. The contract encompasses comprehensive sewer system services including monthly status reporting, mobilization/demobilization, sewer flow monitoring, manhole-mounted level monitoring, virtual rain sensor maintenance, sewer condition assessment, and GPS survey documentation. The project involves 33 flow meter sites, 30 meter installations, 720 monthly maintenance and data submissions, 250 manhole cleanings and inspections, 50 sewer connectivity dye tests, and includes a provisional allowance of $91,470.00 for a total bid amount matching the allowance.
The pricing form indicates a two-year contract term with specific unit-based pricing for various technical services related to sewer system assessment and monitoring. The project aims to refine calibration of Detroit's all-pipe sewer model by collecting data in strategic sewer-sheds where major flows are currently unmonitored. The provisional allowance suggests flexibility for potential additional work or unexpected project requirements. The comprehensive scope suggests a detailed, systematic approach to infrastructure assessment, with precise tracking of activities through unit-based measurements and consistent documentation requirements across multiple monitoring and inspection activities.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Attachment E - Pricing Form |
| Company Name: |
Project Name: Local Sewer System Metering and Condition Assessment
Project Number: CS-1998
| Item No. | WBS | Item Code | Description | Standard Specification | Unit of Measure | Estimated Quantity | Bid Unit Prices | Bid Amount |
| Project Administration | ||||||||
| 1 | 601 | 1000.0004 | Monthly Status Report | Exhibit A | EA | 24 | $ - 0 | |
| 2 | 601 | 1000.0000 | Mobilization/Demobilization | 01 20 00 | LS | 1 | $ - 0 |
| Sewer Flow Monitoring | |||||||
| 3 | 110 | 1000.0012 | Site Reconnaissance per FM site | RFB Attachment C | EA | 33 | $ - 0 |
| 4 | 110 | 1000.0012 | Flow Meter installation, and removal | RFB Attachment C | EA | 30 | $ - 0 |
| 5 | 110 | 1000.0012 | Monthly Maintenance, and Data submittals per FM site per month | RFB Attachment C | EA | 720 | $ - 0 |
| Sewer Manhole Mounted Level Monitoring | |||||||
| 6 | 110 | 1000.0012 | Site Reconnaissance per Manhole Mounted Level Monitoring site | RFB Attachment C | EA | 22 | $ - 0 |
| 7 | 110 | 1000.0012 | Manhole Mounted Level Monitoring installation, and removal | RFB Attachment C | EA | 20 | $ - 0 |
| 8 | 110 | 1000.0012 | Monthly Maintenance, and Data submittals per Manhole Mounted Level Monitoring site per year | RFB Attachment C | EA | 40 | $ - 0 |
| Virtual Rain Sensor | |||||||
| 9 | 110 | 1000.0012 | Monthly Maintenance, and Data submittals per Virtual Rain Sensor site per year | RFB Attachment C | EA | 20 | $ - 0 |
| Sewer Condition Assessment | |||||||
| 10 | 655 | 4260.0000 | Manhole, Clean | 33 01 30.19 | EA | 250 | $ - 0 |
| 11 | 110 | 4270.0001 | Manhole Panoramic Inspection | 33 01 30.17 | EA | 250 | $ - 0 |
| 12 | 110 | 4380.0000 | Sewer Inspection Dye Testing for Connectivity | RFB Attachment C | EA | 50 | $ - 0 |
| GPS Survey | |||||||
| 13 | 645 | 4390.0000 | GPS Structure Documentation Sewer - Manholes | 01 32 25 | EA | 250 | $ - 0 |
| Allowance | ||||||||
| 14 | 670 | 9020.0000 | Provisional Allowance | 01 20 00 | ALLOW | 1 | $ 91,470.00 | $ 91,470.00 |
TOTAL BID AMOUNT $ 91,470.00