A - OUTFITTER BUILDING
B - RESTROOM BUILDING
C - CONCESSIONS & DINING PAVILION
D - MUSIC STAGE
E - STORAGE BUILDING
F - FISHING PIER
PROJECT KEY
E B
D
F C
A
0" 1"
N
PROJECT MANAGER:
A/E OF RECORD:
PROJECT NO:
(C) COPYRIGHT 2021 SWEET SPARKMAN ARCHITECTS, INC.
SHEET TITLE:
SHEET No.:
SCALE:
DRAWN BY:
REV DESCRIPTION DATE
GRAPHIC SCALE:
N O
T F
O R
C O
N S
T R
U C
T
IO
N
SITE LOCATION MAP
NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTION
PROJECT TEAM
P R
O J E
C T
IT
L E
IS
S
U E
D
F O
R
M A
IN
S
T R
E E
T
S U
IT
E
S A
R A
S O
T A
, F L
S W
E E
T S
P A
R K
M A
N .C
O M
T
.9
.0
F L
A R
DRAWING SET:
C L
IE
N T
A D
D R
E S
S
1/4" = 1'-0"
22716
COVER
GA001
SNOOK HAVEN PARK IMPROVEMENTS
5000 E. VENICE AVENUE, VENICE, FL 34292
SARASOTA COUNTY
5000 E. VENICE AVENUE, VENICE, FL 34292
D E
S
IG
N D
E V
E L O
P M
E N
T
S N
O O
K H
A V
E N
P A
R K
IM
P
R O
V E
M E
N T
S
S A
R A
S O
T A
C O
U N
T Y
E
V
E N
IC
E
A V
E N
U E
V
E N
IC
E
F
L
JWB
TMS
JFO
OUTFITTER BUILDING
TABLE OF CONTENTS
ARCHITECT:
SWEET SPARKMAN ARCHITECTS &
INTERIORS
1819 MAIN ST, SUITE 400
SARASOTA, FL 34236
CONTACT: JOHN BRYANT
CONTACT TITLE: PRINCIPAL
PHONE: 941.952.0084
EMAIL: JBRYANT@SWEETSPARKMAN.COM
OWNER:
SARASOTA COUNTY
1001 SARASOTA CENTER BLVD.
SARASOTA, FL, 34240
CONTACT: BRAD GAUBATZ
CONTACT TITLE: OPERATIONAL MANAGER III
PHONE: 941.0861.0853
EMAIL: BGAUBATZ@SCGOV.NET
CONTACT: RONNIE HART
CONTACT TITLE: PROJECT MANAGER III
PHONE: 941.882.0605
EMAIL: RHART@SCGOV.NET
CIVIL ENGINEER:
BGE, INC.
551 N.CATTLEMEN ROAD, SUITE 104
SARASOTA, FL 34232
CONTACT: DANIEL J. BOND, P.E.
CONTACT TITLE: DIRECTOR, LAND/SITE
PHONE: 941.208.2008
EMAIL: DBOND@BGEINC.COM
LANDSCAPE ARCHITECT:
KIMLEY-HORN AND ASSOCIATES, INC.
1800 SECOND STREET, SUITE 900,
SARASOTA, FL 34236
CONTACT: KELSIE SHY, P.L.A.
CONTACT TITLE: LANDSCAPE ARCHITECT
PHONE: 941.379.7665
EMAIL: KELSIE.SHY@KIMLEY-HORN.COM
ENVIRONMENTAL CONSULTANT:
MONARCH ECOLOGY GROUP, LLC
3431 PINE VALLEY DRIVE
SARASOTA, FL 34239
CONTACT: KERRY MACNUTT
CONTACT TITLE: PRINCIPAL
PHONE: 941.374.6339
EMAIL: KMACNUTT@MONARCHECOLOGY.COM
STRUCTURAL ENGINEER:
HEES & ASSOCIATES + BENNETT & PLESS,
INC.
1381 5TH STREET,
SARASOTA, FLORIDA 34236
CONTACT: KARL HEES, P.E., S.I., F. ASCE
CONTACT TITLE: PRESIDENT
PHONE: 941.955.4555
EMAIL: KHEES@BENNETT-PLESS.COM
MEP ENGINEER:
CRAWFORD WILLIAM ENGINEERING, INC.
6989 PROFESSIONAL PARKWAY EAST,
SARASOTA, FL 34240
CONTACT: SCOTT CRAWFORD
CONTACT TITLE: CHIEF PRINCIPAL
PHONE: 941.907.0103
EMAIL: SCOTT@CRAWFORDWILLIAMS.COM
FOOD SERVICE:
FISHMAN & ASSOCIATES
143 EAST MIAMI AVENUE
VENICE, FL 34285
CONTACT: JENNIFER STOTT
CONTACT TITLE: FOOD SERVICE CONSULTANT
PHONE: 941.336.5037
EMAIL: JENNIFER@FISHMANINC.COM
GENERAL
ARCHITECTURAL
GA001 COVER
AA101 FLOOR PLAN & RCP - DEMOLITION
AA111 FLOOR PLAN, RCP & ROOF PLAN - RENOVATION
AA201 BUILDING ELEVATIONS
AA301 BUILDING AND WALL SECTIONS
AA501 PARTITION TYPES & DETAILS
AA601 SCHEDULES, LEGENDS & DETAILS
MYAKKA RIVER
MYAKKA RIVER
A - OUTFITTER BUILDING
SHEET NOTES
NUMBERED NOTES SHOWN IN DRAWINGS ON THIS
SHEET APPLY ONLY TO THE NUMBERED NOTES IN
THE TABLE BELOW.
42' - 2"
6'
1'
3'
TYP
TYP
TYP
TYP
TYP
TYP
7 7
EXISTING DOOR TO BE REMOVED
EXISTING WALLS TO BE REMOVED
EXISTING WALLS TO REMAIN
DEMOLITION WALL LEGEND
MOISTURE RESISTANT GYPSUM
BOARD CEILING
ACOUSTICAL PANEL CEILING
EXIT SIGN
WALL MOUNTED LIGHT FIXTURE
SPRINKLER
RECESSED LIGHT
2' X 2' LIGHT FIXTURE
CEILING FAN
CEILING ACCESS PANEL
WOOD COMPOSITE CEILING
SUSPENDED LIGHT FIXTURE
WALL MOUNTED LIGHT FIXTURE
0" 1"
N
PROJECT MANAGER:
A/E OF RECORD:
PROJECT NO:
(C) COPYRIGHT 2021 SWEET SPARKMAN ARCHITECTS, INC.
SHEET TITLE:
SHEET No.:
SCALE:
DRAWN BY:
REV DESCRIPTION DATE
GRAPHIC SCALE:
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
O J E
L E
IS
S
U
R
M A
IN
S
T R
E E
T
S U
IT
E
S A
R A
S O
T A
, F L
S W
E E
T S
P A
R K
M A
N .C
O M
T
.9
.0
F L
A R
T O
D D
M S
W E
E T
A R
DRAWING SET:
C L
IE
N T
A D
D R
E S
S
As indicated
22716
FLOOR PLAN & RCP -
DEMOLITION
AA101
D E
S
IG
N D
E V
E L O
P M
E N
T
S N
O O
K H
A V
E N
P A
R K
IM
P
R O
V E
M E
N T
S
S A
R A
S O
T A
C O
U N
T Y
E
V
E N
IC
E
A V
E N
U E
V
E N
IC
E
F
L
/1
/2
JWB
TMS
JFO
OUTFITTER BUILDING
1/4" = 1'-0"
FLOOR PLAN - DEMOLITION
DEMOLITION NOTES:
1 REMOVE ALL EXISTING WINDOWS, DOORS, PARTITIONS,
AND FINISHES AS REQUIRED TO PREPARE BUILDING FOR
RENOVATION PER PLAN.
2 DEMO WALL AS SHOWN FOR NEW DOOR OPENING.
3 REMOVE MASONRY PLANTER.
4 REMOVE WINDOW SHUTTERS, TYP.
5 REMOVE CONCRETE WINDOW SILLS, TYP.
6 REMOVE EXISTING PLUMBING FIXTURE, REFER TO
PLUMBING.
7 REMOVE EXISTING APPLIANCES AND TURN OVER TO
OWNER.
1/4" = 1'-0"
REFLECTED CEILING PLAN - DEMOLITION
1 REMOVE EXISTING CEILING, INCLUDING LIGHT FIXTURES
AND MECHANICAL DEVICES.
REFLECTED CEILING PLAN DEMO NOTES:
N.T.S
LEGEND - REFLECTED CEILING
SHEET APPLY ONLY TO THE NUMBERED NOTES IN
THE TABLE BELOW.
AA301
AA301
AA301
AA301
STORAGE
102 CHECK IN / OUT
RR
OFFICE
AA301
AA301
A.F.F.7' - 3"
A.F.F.7' - 3"
A.F.F.7' - 3" A.F.F.7' - 3"
STORAGE
100A
2'
4'
/4
2'
AA2011
AA201
AA201 3
AA201
CHECK IN / OUT
STORAGE
RR
AA301
AA301
42' - 2" (V.I.F.)
AA301
AA301
OFFICE
9'
1A
1E1A
(V .I.
F
1 1
TYP
AA301
AA301
10' - 5"
2A
AA111
TYP
STORAGE
100A
4B 4B
4B
4B
4B4B
NEW CMU WALLS. FURRING/FACING
CONDITIONS MAY VARY BY TYPE
NEW STUD WALLS. FACING CONDITIONS
MAY VARY BY TYPE
CONC WALLS
EXISTING WALLS.
REFER TO AA501 FOR INTERIOR PARTITION TYPES.
REFER TO WALL SECTIONS FOR EXTERIOR WALL
ASSEMBLIES.
X-X
WALL LEGEND
MOISTURE RESISTANT GYPSUM
BOARD CEILING
ACOUSTICAL PANEL CEILING
EXIT SIGN
WALL MOUNTED LIGHT FIXTURE
SPRINKLER
RECESSED LIGHT
2' X 2' LIGHT FIXTURE
CEILING FAN
CEILING ACCESS PANEL
WOOD COMPOSITE CEILING
SUSPENDED LIGHT FIXTURE
WALL MOUNTED LIGHT FIXTURE
AA301
AA301
AA301
AA301
TYP
AA301
AA301
TYP
TYP
A A
AA111
AA111
A A
GB
BCS
GB
TPD
SND
SD
HD
TPD
BCSSND
GB
GB
BCS
SD
HD
GB
SND
TPD
MIR1
HD
SD
ULPP
M A
X
SOAP
DISPENSER
T O
O P
E N
IN
G
SANITARY
NAPKIN
DISPENSER
PAPER TOWEL
DISPENSER/
WASTE RECEPT.
54" AT TOILET
SIDEWALLS,
36" BEHIND
TOILETS
GRAB BARS
TANK TOILET & TOILET
PAPER DISPENSER
FLUSH VALVE TOILET &
TOILET PAPER DISPENSER
M
A X
T
O P
O F
S E
A T
M
A X
T O
P O
F S
E A
T
18" MAX.
(FRONT) (SIDE)(FRONT) (SIDE)
18" MAX.
3' - 0 1/64"
F O
R W
A R
D R
E A
C H
S
ID
E R
E A
C H
ROBE HOOKS
V A
R
IE
S
ACCESSORY MOUNTING HEIGHT LEGEND
T O
B .O
R
E F
LE
C
T
IN
G
S U
R F
A C
E
M
A X
MIRROR
O
P E
N P
O S
IT
IO
N
LAV.
ULPP
HAND DRYER WASTE
RECEPTACLE
T
O C
O N
T R
O L
S
/3
BABY CHANGING
STATION
(W A
LL
(W A
LL
(W A
LL
(W A
LL
0" 1"
N
PROJECT MANAGER:
A/E OF RECORD:
PROJECT NO:
(C) COPYRIGHT 2021 SWEET SPARKMAN ARCHITECTS, INC.
SHEET TITLE:
SHEET No.:
SCALE:
DRAWN BY:
REV DESCRIPTION DATE
GRAPHIC SCALE:
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
O J E
L E
IS
S
U
R
M A
IN
S
T R
E E
T
S U
IT
E
S A
R A
S O
T A
, F L
S W
E E
T S
P A
R K
M A
N .C
O M
T
.9
.0
F L
A R
T O
D D
M S
W E
E T
A R
DRAWING SET:
C L
IE
N T
A D
D R
E S
S
As indicated
22716
FLOOR PLAN, RCP &
ROOF PLAN -
RENOVATION
AA111
D E
S
IG
N D
E V
E L O
P M
E N
T
S N
O O
K H
A V
E N
P A
R K
IM
P
R O
V E
M E
N T
S
S A
R A
S O
T A
C O
U N
T Y
E
V
E N
IC
E
A V
E N
U E
V
E N
IC
E
F
L
JWB
TMS
JFO
OUTFITTER BUILDING
1/4" = 1'-0"
REFLECTED CEILING PLAN - RENOVATION
1/4" = 1'-0"
FLOOR PLAN - RENOVATION
FLOOR PLAN NOTES:
N.T.S
LEGEND - REFLECTED CEILING
1 LOUVER, REFER TO MECHANICAL.
2 WALL GRAPHIC.
3 DASHED LINE INDICATED ROOF LINE OVERHEAD.
4 WOOD COMPOSITE DECKING.
5 EXHAUST FAN, REFER TO MECHANICAL.
6 THROUGH WALL AIR CONDITIONER, REFER TO
MECHANICAL.
7 DOWNSPOUT, TYP.
1 MOISTURE RESISTANT GYPSUM BOARD
REFLECTED CEILING PLAN NOTES:
1/4" = 1'-0"
OUTFITTER'S CABIN - ROOF PLAN
ROOF PLAN NOTES:
1 EXISTING ROOFING SYSTEM TO REMAIN.
2 NEW HALF ROUND GUTTERS WITH DOWNSPOUTS, TYP.
3 NEW FIBER CEMENT TRIM.
1/4" = 1'-0"
RESTROOM PLAN
1/4" = 1'-0"
RESTROOM ELEVATION A
1/4" = 1'-0"
RESTROOM ELEVATION B
1/4" = 1'-0"
RESTROOM ELEVATION C
1/4" = 1'-0"
RESTROOM ELEVATION D
OFOI: OWNER FURNISH, OWNER INSTALL
OFCI: OWNER FURNISH, CONTRACTOR INSTALL
CFCI: CONTRACTOR FURNISH, CONTRACTOR INSTALL
1. CONTRACTOR TO FURNISH AND INSTALL CONCEALED WOOD BLOCKING
(WITHIN WALLS) AS REQUIRED TO FIRMLY SECURE WALL-MOUNTED
EQUIPMENT AND/OR ACCESSORIES. ALL WOOD BLOCKING IN CONTACT WITH...
NOTES:
ULPP UNDER LAVATORY PIPE PROTECTION
SEE ACC. MOUNTING
HEIGHT LEGEND
C-FCI
TPD TOILET PAPER DISPENSER
SEE ACC. MOUNTING
HEIGHT LEGEND
O-FCI
SND SANITARY NAPKIN DISPOSAL
SEE ACC. MOUNTING
HEIGHT LEGEND
C-FCI
SD SOAP DISPENSER
SEE ACC. MOUNTING
HEIGHT LEGEND
O-FCI
PTD PAPER TOWEL DISPENSER
SEE ACC. MOUNTING
HEIGHT LEGEND
O-FCI
MIR1 MIRROR
SEE ACC. MOUNTING
HEIGHT LEGEND
C-FCI
BCS BABY CHANGING STATION
SEE ACC. MOUNTING
HEIGHT LEGEND
C-FCI
GB GRAB BAR
SEE ACC. MOUNTING
HEIGHT LEGEND
C-FCI
ITEM DESCRIPTION MOUNTING HEIGHT BY
ACCESSORIES SCHEDULE
7.62NAVD
OUTFITTER - F.F.
14.95NAVD
OUTFITTER - ROOF BRG.
TYP
AA301
AA301
TYP
12 12
TYP
7.62 NAVD
OUTFITTER - F.F.
AA301
AA301
14.95 NAVD
OUTFITTER - ROOF BRG.
AA301
AA301
TYP
7.62 NAVD
OUTFITTER - F.F.
AA301
AA301
14.95 NAVD
OUTFITTER - ROOF BRG.
AA301
AA301
7.62NAVD
OUTFITTER - F.F.
14.95NAVD
OUTFITTER - ROOF BRG.
AA301
TYP
11 13
SHEET NOTES
NUMBERED NOTES SHOWN IN DRAWINGS ON THIS
SHEET APPLY ONLY TO THE NUMBERED NOTES IN
THE TABLE BELOW.
1/4" = 1'-0"
NORTH ELEVATION
1/4" = 1'-0"
WEST ELEVATION
1/4" = 1'-0"
SOUTH ELEVATION
1/4" = 1'-0"
EAST ELEVATION
0" 1"
PROJECT MANAGER:
A/E OF RECORD:
PROJECT NO:
(C) COPYRIGHT 2021 SWEET SPARKMAN ARCHITECTS, INC.
SHEET TITLE:
SHEET No.:
SCALE:
DRAWN BY:
REV DESCRIPTION DATE
GRAPHIC SCALE:
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
O J E
L E
IS
S
U
R
M A
IN
S
T R
E E
T
S U
IT
E
S A
R A
S O
T A
, F L
S W
E E
T S
P A
R K
M A
N .C
O M
T
.9
.0
F L
A R
DRAWING SET:
C L
IE
N T
A D
D R
E S
S
As indicated
22716
BUILDING ELEVATIONS
AA201
D E
S
IG
N D
E V
E L O
P M
E N
T
S N
O O
K H
A V
E N
P A
R K
IM
P
R O
V E
M E
N T
S
S A
R A
S O
T A
C O
U N
T Y
E
V
E N
IC
E
A V
E N
U E
V
E N
IC
E
F
L
/1
/2
JWB
TMS
JFO
OUTFITTER BUILDING
ELEVATION NOTES:
1 EXISTING ROOF SYSTEM.
2 HALF ROUND 26 GAUGE GALVALUME GUTTER WITH
DOWNSPOUTS.
3 LISTED AND APPROVED FIBER CEMENT CLADDING AND
TRIM SYSTEM.
4 LISTED AND APPROVED FIBER CEMENT TRIM MEMBERS
OVER EXPOSED PT LUMBER FRAMING.
5 WALL GRAPHIC. VERBIAGE AND IMAGE TO BE DETERMINED.
6 CUSTOM RAILING WITH WOOD COMPOSITE PICKETS, 2X12
TOP RAIL, AND EXPOSED PT LUMBER FRAMING MEMBERS.
7 DASHED LINE INDICATES LOUVERS BEYOND FIBER CEMENT
CLADDING, REFER TO MECHANICAL.
8 LIGHT FIXTURE, REFER TO ELECTRICAL.
9 NEW FAN, REFER TO ELECTRICAL.
10 METAL SIGN.
11 EXISTING VENT.
12 EXPOSED WOOD FRAMING. REFER TO STRUCTURAL.
13 FASCIA AND METAL DRIP EDGE.
14 EXISTING ELECTRICAL EQUIPMENT.
15 PAINT EXPOSED CONCRETE.
16 THROUGH WALL AIR CONDITIONER, REFER TO
MECHANICAL.
17 HEIGHT TO BOTTOM OF SIDING ABOVE GRADE PER
MANUFACTURER. BEGIN AT HIGHEST POINT.
18 LISTED AND APPROVED OPERABLE ALUMINUM WINDOW.
SHEET APPLY ONLY TO THE NUMBERED NOTES IN
THE TABLE BELOW.
7.62NAVD
OUTFITTER - F.F.
14.95NAVD
OUTFITTER - ROOF BRG.
STORAGE
CHECK IN / OUT
1 1
AA301
Sim
7.62NAVD
OUTFITTER - F.F.
14.95NAVD
OUTFITTER - ROOF BRG.
CHECK IN / OUT
AA301
AA301
7.62NAVD
OUTFITTER - F.F.
14.95NAVD
OUTFITTER - ROOF BRG.
487 SF
STORAGE
OFFICE
AA301
7.62NAVD
OUTFITTER - F.F.
14.95NAVD
OUTFITTER - ROOF BRG.
NEW WOOD COMPOSITE
FLOORING ON 2X PT
FRAMING PER STRUCTURAL.
EXISTING CONCRETE SLAB
AND FOUNDATION.
NEW FIBER CEMENT BOARD SYSTEM
AND 2X PT FRAMING PER
SPECIFICATION.
EXISTING ROOF SYSTEM TO REMAIN.
NEW ALUM. DRIP EDGE
FLASHING AND HALF-
ROUND GUTTER.
NEW FIBER
CEMENT TRIM. CEILING AS SCHEDULED ON
PT FURRING STRIPS.
NEW WOOD BEAM PER
STRUCTURAL.
EXISTING WOOD COLUMN PER
STRUCTURAL.
WOOD FURRING AS REQUIRED.
7.62NAVD
OUTFITTER - F.F.
14.95NAVD
OUTFITTER - ROOF BRG.
CEILING AS SCHEDULED.
NEW FIBER CEMENT TRIM.
EXISTING ROOF SYSTEM TO REMAIN.
NEW ALUM. DRIP EDGE FLASHING
AND HALF-ROUND GUTTER.
NEW FLUID APPLIED
WATERPROOFING OVER EXISTING
WOOD CONSTRUCTION.
NEW FIBER CEMENT BOARD AND
BATTEN SYSTEM PER SPECIFICATION.
FIELD FABRICATED BARN SHUTTER
EXISTING WOOD
STRUCTURE
EXISTING CONCRETE
SLAB AND FOUNDATION
NEW COMPOSITE
FLOORING
ALUMINUM FLASHING.
P E
R M
A N
F
7.62NAVD
OUTFITTER - F.F.
14.95NAVD
OUTFITTER - ROOF BRG.
NEW ALUM. DRIP EDGE FLASHING
AND HALF-ROUND GUTTER.
EXISTING ROOF SYSTEM TO REMAIN.
EXISTING CMU WALL AND
FOUNDATION.
NEW LOUVER, REFER TO
MECHANICAL
NEW FLUID APPLIED WATERPROOFING
OVER EXISTING CONSTRUCTION.
NEW FIBER CEMENT BOARD AND
BATTEN SYSTEM PER SPECIFICATION.
NEW FIBER CEMENT TRIM.
FIBER CEMENT BATTEN OVER
LOUVER OPENING.
CEILING AS SCHEDULED.
EXISTING CONCRETE
SLAB
NEW WOOD BLOCKING AS REQUIRED.
NEW ALUMINUM
FLASHING
0" 1"
PROJECT MANAGER:
A/E OF RECORD:
PROJECT NO:
(C) COPYRIGHT 2021 SWEET SPARKMAN ARCHITECTS, INC.
SHEET TITLE:
SHEET No.:
SCALE:
DRAWN BY:
REV DESCRIPTION DATE
GRAPHIC SCALE:
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
O J E
L E
IS
S
U
R
M A
IN
S
T R
E E
T
S U
IT
E
S A
R A
S O
T A
, F L
S W
E E
T S
P A
R K
M A
N .C
O M
T
.9
.0
F L
A R
DRAWING SET:
C L
IE
N T
A D
D R
E S
S
As indicated
22716
BUILDING AND WALL
SECTIONS
AA301
D E
S
IG
N D
E V
E L O
P M
E N
T
S N
O O
K H
A V
E N
P A
R K
IM
P
R O
V E
M E
N T
S
S A
R A
S O
T A
C O
U N
T Y
E
V
E N
IC
E
A V
E N
U E
V
E N
IC
E
F
L
JWB
TMS
JFO
OUTFITTER BUILDING
SECTION NOTES:
1/4" = 1'-0"
OC - BUILDING SECTION - LONGITUDINAL
1/4" = 1'-0"
BUILDING SECTION - TRANSVERSE
1/4" = 1'-0"
BUILDING SECTION - TRANSVERSE
3/4" = 1'-0"
WALL SECTION 1
3/4" = 1'-0"
WALL SECTION 2
3/4" = 1'-0"
WALL SECTION 3
1 EXISTING ROOF CONSTRUCTION TO REMAIN.
2 PAINT EXISTING BLOCK, REFER TO FINISH SCHEDULE.
TYPE 1 - STUD PARTITION WALL
TOP OF FLOOR
BASE PER FINISH SCHED.
METAL STUD FRAMING
(SIZE PER SCHEDULE)
A S
N O
T E
D P
A R
T
IT
IO
N
H E
IG
H
T
CEILING AS
SCHEDULED
TYPE 2 - STUD PARTITION WALL - PARTIAL HEIGHT
TOP OF FLOOR
BRACE WALL TO
STRUCTURE OR DECK
TYPE 4 - FURRING WALL - NON-INSULATED
FIRE SAFING, BOTH
SIDES AT RATED
WALLS (TYP)
CEILING AS SCHEDULED
5/8" GWB (BOTH SIDES)
BASE PER FINISH SCHED.
METAL STUD FRAMING
(SIZE PER SCHEDULE)
5/8" GWB (BOTH SIDES)
BATT INSULATION FOR
SOUNDPROOFING
(UNLESS NOTED
OTHERWISE IN SCHED.)
TOP OF FLOOR
BOTTOM OF DECK
BASE PER FINISH SCHED.
METAL STUD FRAMING
(SIZE PER SCHEDULE)
5/8" GWB
EXTERIOR AND/OR
STRUCTURAL WALL. REFER
TO WALL SECTION AND
STRUCTURAL AS
APPROPRIATE.
ACOUSTICAL SEALANT
(BOTH SIDES), WHEN
BATT INSULATION IS
INDICATED
BATT INSULATION FOR
SOUNDPROOFING
(UNLESS NOTED
OTHERWISE IN SCHED.)
ACOUSTICAL SEALANT
(BOTH SIDES), WHEN
BATT INSULATION IS
INDICATED
ACOUSTICAL SEALANT
(BOTH SIDES), WHEN
BATT INSULATION IS
INDICATED
BOTTOM OF DECK
OR RATED ASSEMBLY
TYPE DESCRIPTION HEIGHT
FIRE
RATING
4B
1-5/8" METAL STUD N/A6" ABV
CEILING
TYPE DESCRIPTION HEIGHT
FIRE
RATING
2A
3-5/8" METAL STUD N/A6" ABV
CEILING
TYPE DESCRIPTION HEIGHT
FIRE
RATING
1A
3-5/8" METAL STUD N/AFULL HT
TO DECK
1E
6" METAL STUD N/AFULL HT
TO DECK
PARTITION TYPE NOTES
1. PARTITION TYPES ARE TAGGED ON THE FLOOR PLANS.
2. REFER TO WALL SECTIONS FOR EXTERIOR WALL ASSEMBLIES.
3. REFER TO “GYPSUM BOARD ASSEMBLIES” SPECIFICATION FOR FULL REQUIREMENTS
FOR GYPSUM BOARD ASSEMBLIES AND NON-LOAD-BEARING STEEL FRAMING MEMBERS
FOR GYPSUM BOARD ASSEMBLIES.
4. ALL STUDS AND FURRING CHANNELS ARE TO BE SPACED 16" O.C., UNLESS NOTED
OTHERWISE.
5. ALL PARTITIONS SHALL EXTEND FROM FLOOR SLAB OR DECK TO THE UNDERSIDE OF
THE STRUCTURAL DECK TO ACHIEVE COMPLETE CLOSURE, UNLESS NOTED OTHERWISE.
6. PARTITION TYPES DESCRIBE THE PRIMARY WALL MEMBER AND SHEATHING. REFER TO
FINISH SCHEDULE FOR ALL PARTITION FINISH DESIGNATIONS.
7. PROVIDE TYPE “M-R” MOISTURE RESISTANT GYPSUM BACKING BOARD IN ALL WET
AREAS, INCLUDING TOILET, LOCKER AND SHOWER ROOMS.
8. PROVIDE 1/2” CEMENT BOARD WITH WATER-RESISTANT COATING AS A SUBSTRATE FOR
WALL AREAS SCHEDULED TO RECEIVE TILE.
9. CONSTRUCTION OF FIRE RATED PARTITIONS, INCLUDING TAPING AND FINISHING OF
GYPSUM BOARD, SHALL BE IN ACCORDANCE WITH U.L. SYSTEM ASSEMBLY OR OTHER
APPROVED ASSEMBLY TO ACHIEVE THE RATING INDICATED. PROVIDE FIRESTOPPING
PER FIRESTOPPING MANUFACTURER’S RECOMMENDATIONS FOR PENETRATIONS
THROUGH RATED WALLS.
10. PROVIDE SLIP JOINT CONNECTIONS AT THE TOPS OF ALL PARTITIONS WHICH INTERSECT
THE STRUCTURE ABOVE, CAPABLE OF ACCOMMODATING UPWARD AND DOWNWARD
VERTICAL DISPLACEMENT OF PRIMARY STRUCTURE THROUGH POSITIVE MECHANICAL
ATTACHMENT TO STUD WEB. PROVIDE FIRE SAFING AT ALL SLIP JOINT CONNECTIONS IN
FIRE RATED PARTITIONS.
11. PROVIDE GYPSUM BOARD CONTROL JOINTS WHERE DESIGNATED ON THE INTERIOR
ELEVATIONS, AND ANYWHERE THERE IS A CONTINUOUS RUN OF GYPSUM BOARD THAT
IS GREATER THAN 30 FEET IN LENGTH. CONFIRM THE LOCATION OF ADDITIONAL
CONTROL JOINTS WITH THE ARCHITECTURE PRIOR TO INSTALLATION.
12. IN PARTITIONS WHERE BATT INSULATION FOR SOUNDPROOFING IS INDICATED, SEAL
CONSTRUCTION AT PERIMETERS, BEHIND CONTROL AND EXPANSION JOINNTS,
OPENINGS, AND PENETRATIONS WITH A CONTINUOUS BEAD OF ACOUSTICAL SEALANT,
INCLUDING A BEAD AT BOTH FACES OF THE PARTITIONS.
13. AT METAL STUD WALLS, BLOCKING IS REQUIRED AT ALL WALL MOUNTED ITEMS
INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING LOCATIONS:
A. WALL MOUNTED COUNTERS AND COUNTERTOP SUPPORTS
B. WALL MOUNTED ACCESSORIES AND EQUIPMENT
C. WALL MOUNTED DOORSTOPS
D. WALL MOUNTED DOOR HOLD OPEN DEVICES AND/OR CLOSURES
E. TOILET ROOM PARTITIONS AND ACCESSORIES
F. WALL MOUNTED TV / MONITORS AND BRACKETS
FIRE RESISTANCE RATING OF CONCRETE MASONRY WALLS
PER FBC BUILDING TABLE 722.3.2, THE FIRE RESISTANCE RATING OF
WALLS AND PARTITIONS CONSTRUCTION OF CONCRETE MASONRY UNITS
SHALL BE BASED ON THE EQUIVALENT THICKNESS OF THE MASONRY
AND TYPE USED.
CALCAREOUS OR SILICEOUS GRAVEL AGGREGATE
1 HOUR RATING = 2.8” MINIMUM EQUIVALENT THICKNESS
2 HOUR RATING = 4.2” MINIMUM EQUIVALENT THICKNESS
0" 1"
PROJECT MANAGER:
A/E OF RECORD:
PROJECT NO:
(C) COPYRIGHT 2021 SWEET SPARKMAN ARCHITECTS, INC.
SHEET TITLE:
SHEET No.:
SCALE:
DRAWN BY:
REV DESCRIPTION DATE
GRAPHIC SCALE:
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
O J E
L E
IS
S
U
R
M A
IN
S
T R
E E
T
S U
IT
E
S A
R A
S O
T A
, F L
S W
E E
T S
P A
R K
M A
N .C
O M
T
.9
.0
F L
A R
DRAWING SET:
C L
IE
N T
A D
D R
E S
S
1 1/2" = 1'-0"
22716
PARTITION TYPES &
DETAILS
AA501
D E
S
IG
N D
E V
E L O
P M
E N
T
S N
O O
K H
A V
E N
P A
R K
IM
P
R O
V E
M E
N T
S
S A
R A
S O
T A
C O
U N
T Y
E
V
E N
IC
E
A V
E N
U E
V
E N
IC
E
F
L
JWB
TMS
JFO
OUTFITTER BUILDING
1 1/2" = 1'-0"
PARTITION TYPES
FLUSH
A
P E
R S
C H
E D
U
LE
PER SCHEDULE
FLUSH DOUBLE DOOR
WITH LOUVERS
4"
0"
L
6" 6"
P E
R S
C H
E D
U
LE
PER SCHEDULE
0"
7"
C
FLUSH LOUVER
PER SCHEDULE
6" 6"
P E
R S
C H
E D
U
LE
24"
4"
2'
B
FLUSH LOUVER
(ALTERNATE)
P E
R S
C H
E D
U
LE
PER SCHEDULE
6" 6"
0'
0' - 2"
0'
0' - 2" 0' - 2"0' - 2"
1 2
GENERAL FINISH NOTES:
A. REFER TO WALL LEGEND, PLANS &/OR SECTIONS FOR FINISH SUBSTRATE.
B. WHERE 2 OR MORE FINISHES ARE SCHEDULED, SEE FLOOR PLAN, REFLECTED
CEILING PLAN, OR INTERIOR ELEVATIONS FOR EXTENTS.
C. REFER TO REFLECTED CEILING PLANS FOR CEILING HEIGHTS.
D. ONLY FINISH NON PRE-FINISHED ITEMS.
FINISH SCHEDULE REMARKS:
1. ADD REMARKS AS NEEDED. PLACE NUMBER IN "REMARKS" COLUMN, AND THEN ADD
NOTE HERE.
GENERAL DOOR NOTES:
A. ALL HM AND WOOD DOORS ARE 1-3/4" THICKNESS UNLESS NOTED OTHERWISE.
B. ALL HM FRAMES ARE 2" WIDE & 5-3/4" DEEP UNLESS NOTED OTHERWISE IN
REMARKS. SEE TYPICAL FRAME ELEVATION BELOW. STOREFRONT AND
GLAZING SYSTEM FRAMES DEPTHS ARE BY MANUFACTURER.
C. REFER TO GLAZING SPECIFICATION FOR GLASS TYPES IN INTERIOR &
EXTERIOR DOORS.
DOOR SCHEDULE REMARKS:
1. PROJECT ALTERNATE: DOOR TYPE B
0" 1"
PROJECT MANAGER:
A/E OF RECORD:
PROJECT NO:
(C) COPYRIGHT 2021 SWEET SPARKMAN ARCHITECTS, INC.
SHEET TITLE:
SHEET No.:
SCALE:
DRAWN BY:
REV DESCRIPTION DATE
GRAPHIC SCALE:
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
O J E
L E
IS
S
U
R
M A
IN
S
T R
E E
T
S U
IT
E
S A
R A
S O
T A
, F L
S W
E E
T S
P A
R K
M A
N .C
O M
T
.9
.0
F L
A R
DRAWING SET:
C L
IE
N T
A D
D R
E S
S
1/4" = 1'-0"
22716
SCHEDULES,
LEGENDS & DETAILS
AA601
D E
S
IG
N D
E V
E L O
P M
E N
T
S N
O O
K H
A V
E N
P A
R K
IM
P
R O
V E
M E
N T
S
S A
R A
S O
T A
C O
U N
T Y
E
V
E N
IC
E
A V
E N
U E
V
E N
IC
E
F
L
JWB
TMS
JFO
OUTFITTER BUILDING
1/4" = 1'-0"
LEGEND - DOOR TYPES
1/4" = 1'-0"
LEGEND - TYPES DOOR FRAME
DOOR SCHEDULE - OUTFITTER
DOOR
NUMBER INT/EXT TYPE WIDTH HEIGHT MATERIAL FINISH
FIRE
RATING HARDWARE
FRAME
REMARKSTYPE MATERIAL FINISH
100 EXT A 3' - 0" 6' - 8" WD PNT N/A 1 HM PNT
101 EXT C 3' - 0" 6' - 6" HM PNT 2 HM PNT 1
102 EXT JJ 6' - 0" 6' - 6" HM PNT 2 HM PNT
103 INT A 3' - 0" 7' - 0" WD PNT N/A 1 HM PNT
FINISH SCHEDULE - OUTFITTERS
NUMBER NAME
FINISH
COMMENTSFLOOR BASE WALL CEILING
100 CHECK IN / OUT WD1 N/A PNT1 WD1
100A STORAGE WD1 N/A PNT1 WD1
101 RR UR1 UR1 PNT1 PNT1
102 STORAGE CC1 N/A PNT1 PNT1
103 OFFICE CC1 N/A PNT1 ACT1
FINISH SELECTIONS LEGEND - OUTFITTERS
ITEM MATERIAL MANUFACTURER DESCRIPTION COLOR
ACT1 ACOUSTIC CEILING TILE
CC1 CONCRETE SEALED CONCRETE
PNT1 PAINT SHERWIN WILLIAMS GENERAL PAINT TBD
UR1 URETHANE
WD1 COMPOSITE WOOD DECKING MOISTURESHIELD VANTAGE TBD
KIPS (1000#)
KIPS PER SQUARE INCH
KIPS PER SQUARE FOOT
POUND
LONG LEG HORIZONTAL
LONG LEG VERTICAL
MAXIMUM
MEZZANINE
MANUFACTURER
MINIMUM
MISCELLANEOUS
NEAR SIDE
NOT TO SCALE
NUMBER OR REBAR SIZE
OPPOSITE HAND
ON CENTER
POWDER ACTUATED FASTENER
POUNDS PER LINEAR FOOT
POUNDS PER CUBIC FOOT
POUNDS PER CUBIC INCH
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
POST TENSIONED
PROJECTION
REVISION
REFERENCE
REINFORCING
REQUIRED
SIMILAR
SCHEDULE
SHORT LEG HORIZONTAL
SHORT LEG VERTICAL
SPECIFICATION
SQUARE
SQUARE FEET
STAINLESS STEEL
STANDARD
STIFFENER
STEEL
STRUCTURAL
SYMMETRICAL
THICKENED EDGE
THREAD
THICK
TREAD
TOP OF WALL
TEMPORARY
THROUGH
TOP OF STEEL
TYPICAL
UNLESS NOTED OTHERWISE
WALL CONTROL JOINT
WEIGHT
WITH
WITHOUT
WELDED WIRE FABRIC
ANCHOR BOLT
ABOVE FINISHED FLOOR
ALUMINUM
ALTERNATE
AND
APPROXIMATE
APPROVED
AT
AVERAGE
BUILDING
BOTTOM
CENTERLINE
CLEAR OR CLEARANCE
CONNECTION
CONCRETE MASONRY UNIT
CONSTRUCTION
CONTINUOUS
CONSTRUCTION OR CONTROL JOINT
CONCRETE
COLUMN
CENTER
DIAGONAL
DIAMETER
DIMENSION
DRAWING
DEFORMED BAR ANCHOR
EACH
EACH END
EACH FACE
EXPANSION JOINT
EACH SIDE
EACH WAY
ELEVATION
ELECTRICAL
EMBEDMENT
EQUAL
EQUIPMENT
EXISTING
EXPANSION
EXTENDED
FINISHED FLOOR
FLOOR
FEET OR FOOT
FAR SIDE
FOOTING
FOUNDATION
YIELD STRENGTH
28 DAY COMPRESSIVE STRENGTH
GAUGE OR GAGE
GALVANIZED
GENERAL
HEIGHT
HORIZONTAL
INCH OR INCHES
ISOLATION JOINT
K
KSI
KFS
LLH
LLV
MAX.
MEZZ.
MFR.
MIN.
MISC.
NS
N.T.S.
O.H.
O.C.
P.A.F.
PLF
PCF
PCI
PSF
PSI
P.T.
PROJ.
REV.
REF.
REINF.
REQ'D
SIM.
SCHED.
SLH
SLV
SPEC.
SQ.
SF
S.S.
STD.
STIFF.
STL.
STRUCT.
SYM.
T.E.
THD.
THK.
TRD.
T/WALL
TEMP.
THRU
T.O.S.
TYP.
U.N.O.
W.C.J.
WT.
W/ W/O
WWF
A.B.
A.F.F.
AL.
ALT.
APPROX.
APPVD.
AVG.
BLDG.
BOTT.
C.L.
CL. OR CLR.
CONN.
CMU
CONST.
CONT.
C.J.
CONC.
COL.
CTR.
DIAG.
O OR DIAM.
DIM.
DWG
DBA
EA.
E.E.
E.F.
E.J.
E.S.
E.W.
ELAV.
ELEC.
EMBED.
= OR EQ.
EQUIP.
EXIST.
EXP.
EXT.
F.F.
FLR.
FT.
F.S.
FTG.
FOUND.
Fy OR fy f'c
GA.
GALV.
GEN.
HGT.
HORIZ.
IN.
I.J.
A B B R E V I A T I O N S
L E G E N D
ITEM SYMBOL
MINUS OR COMPRESSION
TOP OF STEEL ELEVATION
STEP IN STRUCTURE
POUNDS (FOLLOWING)
AND
CENTERLINE
NUMBER (PRECEDING)
PLUS OR TENSION
PLATE
T/S EL. +20'-8"
(+20'-0")
OR
+0'-0"
#, NO.
P C
8" S S
S2 B
OR DEPRESSED SLAB
S2
L L
C1 F2.0A -2'-0"
CONCRETE
GROUT
EARTH
CONCRETE BLOCK (CMU)
SECTION INDICATOR
DETAIL INDICATOR
COLUMN TYPE
FOOTING TYPE
TOP OF FOOTING ELEVATION
SPOT ELEVATION TOP OF CONCRETE
STEP IN FTG. OR GRADE BM.
TO CLG. PLUMB.
CENTERLINE BEAM SPLICE
PRELIMINARY
NOT FOR CONSTRUCTION
DO NOT SCALE OFF THESE DRAWINGS. LAYOUT THE
BUILDING USING APPLICABLE CONTRACT DRAWINGS,
BUILDING DIMENSIONS AND THE LOCATION OF ALL
STRUCTURAL ELEMENTS INCLUDING BUT NOT LIMITED TO
SLAB EDGES, WALLS, COLUMNS, OPENINGS AND
DEPRESSIONS SHALL BE COORDINATED WITH THE
ARCHITECTURAL DRAWINGS PRIOR TO LAYOUT OF THE
BUILDING. RESOLVE ANY DISCREPANCIES.
TO THE BEST OF THE ENGINEER-OF-RECORD'S
KNOWLEDGE AND ABILITY, THE COMPLETED STRUCTURE
DEPICTED ON THESE DOCUMENTS COMPLIES WITH THE
APPLICABLE MINIMUM BUILDING CODES.
NOTE:
© 2024 - bennett & pless, inc.
All rights reserved.
1381 Fifth Street Sarasota, Florida 34236 Telephone: (941) 955-4555 Fax: (941) 955-9333 www.bennett-pless.com C.O.A. #30502 bennett & pless, inc.
B&P JOB NUMBER 23.03.082
PROJECT MANAGER:
A/E OF RECORD:
PROJECT NO:
(C) COPYRIGHT 2021 SWEET SPARKMAN ARCHITECTS, INC.
SHEET TITLE:
SHEET No.:
SCALE:
DRAWN BY:
REV DESCRIPTION DATE
GRAPHIC SCALE:
N O
T
FO
R C
O N
ST
R
U
CT
IO
N
PR
O
JE
C
T
TI
TL
E:
IS
SU
ED
FO
R
M
AI
N
ST
RE
ET
, S
UI
TE
SA
RA
SO
TA
, F
L 3
SW
EE
TS
PA
RK
MA
N.
CO
M T
1.9
.00
FL
A
R0
DRAWING SET:
C
LI
EN
T:
AD
D
R
ES
S:
22716
GENERAL NOTES &
INFORMATION
SA001
D
ES
IG
N
D
EV
EL
O
PM
EN
T
SN
O
O K
H
AV
EN
P
AR
K
IM
PR
O
VE
M
EN
TS
SA
R
AS
O
TA
C
O U
N
TY
E . V
EN
IC
E
AV
EN
U
E, V
EN
IC
E, F
L
TCW
DEM
OUTFITTER BUILDING
d) THAT THE CONFIGURATION SET FORTH IN THE STRUCTURAL
SUBMITTALS IS CONSISTENT WITH THE CONTRACT
DOCUMENTS. (NO DETAILED CHECK OF DIMENSIONS OR
QUANTITIES WILL BE MADE).
SUBMITTALS NOT MEETING THE CRITERIA LISTED IN THIS SECTION WILL NOT BE
REVIEWED.
FOUNDATIONS:
ARE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF *,*** psf ON
COMPACTED FILL. BEFORE CONSTRUCTION COMMENCES, SOIL BEARING CAPACITY
SHALL BE VERIFIED BY A SUBSURFACE INVESTIGATION, AS WELL AS FIELD AND
LABORATORY TESTS PERFORMED BY A CERTIFIED TESTING LABORATORY, WHOSE
REPORT SHALL INCLUDE ANALYSIS AND RECOMMENDATIONS FOR SITE PREPARATION
IN ORDER TO BEAR THE FOUNDATION LOADS. ABOVE REPORT SHALL BE SUBMITTED
TO THE STRUCTURAL ENGINEER FOR REVIEW BEFORE FOUNDATION CONSTRUCTION
BEGINS.
PENETRATIONS:
NO PENETRATIONS SHALL BE MADE IN ANY STRUCTURAL MEMBERS OTHER THAN
THOSE LOCATED ON THESE DRAWINGS WITHOUT PREVIOUS APPROVAL OF THE
ENGINEER.
FORMWORK AND SHORING:
NO STRUCTURAL CONCRETE SHALL BE STRIPPED UNTIL IT HAS REACHED AT LEAST
TWO THIRDS OF THE 28 DAY DESIGN STRENGTH. DESIGN, ERECTION AND REMOVAL
OF ALL FORMWORK, SHORES AND RESHORES SHALL MEET THE REQUIREMENTS SET
FORTH IN ACI STANDARDS 347 AND 301.
PLUMBING SLEEVE:
MINIMUM SLEEVE SPACING SHALL BE THREE DIAMETERS CENTER TO CENTER OF THE
LARGER SLEEVE OR 6" CLEAR BETWEEN SLEEVES, WHICHEVER IS GREATER. PRIOR
TO CONSTRUCTION SLEEVE LOCATIONS AND SIZES SHALL BE APPROVED BY THE
ENGINEER.
EMBEDDED CONDUITS:
LOCATIONS AND SIZES OF CONDUIT MUST BE APPROVED BY THE ENGINEER PRIOR TO
PLACEMENT. WITHIN SLABS, BEAMS OR WALLS, CONDUIT SHALL OCCUPY ONLY THE
MIDDLE ONE THIRD OF THE MEMBER DEPTH OR THICKNESS. MAXIMUM CONDUIT O.D.
FOR SINGLE CONDUITS OR SUM OF O.D.'S FOR MULTIPLE CONDUITS THAT CROSS
SHALL BE NO LARGER THAN ONE THIRD THE SLAB DEPTH. PARALLEL CONDUITS SHALL
BE SPACED WITH A MINIMUM OF 3 DIAMETERS CLEAR. CONDUITS SHALL BE A MINIMUM
OF ONE DIAMETER AWAY FROM AND SHALL NOT INTERFERE WITH OR DISPLACE ANY
REINFORCING. CONDUIT SHALL NOT BE TIED TO REINFORCING. CONDUITS SHALL NOT
OCCUR WITHIN COLUMN ZONES OF SLABS AND OR TRANSFER GIRDERS. CONDUIT
PLACEMENT SHALL NOT IMPAIR THE STRENGTH OF THE CONSTRUCTION AS JUDGED
BY THE ENGINEER.
REINFORCING STEEL:
SHALL BE ASTM A615 GRADE 60 DEFORMED BARS, FREE FROM OIL, SCALE AND RUST
AND PLACED IN ACCORDANCE WITH THE TYPICAL BENDING DIAGRAM AND PLACING
DETAILS OF ACI STANDARDS AND SPECIFICATIONS. SECURE APPROVAL OF SHOP
DRAWINGS PRIOR TO COMMENCING FABRICATION.
WELDED WIRE FABRIC:
TO CONFORM TO ASTM A-185, FREE FROM OIL, SCALE AND RUST AND PLACED IN
ACCORDANCE WITH THE TYPICAL PLACING DETAILS OF ACI STANDARDS AND
SPECIFICATIONS. MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. USE OF
FLAT MANUFACTURED SHEETS IS RECOMMENDED.
CONCRETE:
SHALL BE PER AN APPROVED MIX DESIGN PROPORTIONED TO ACHIEVE A STRENGTH
AT 28 DAYS AS LISTED BELOW WITH A PLASTIC AND WORKABLE MIX:
5000psi CONCRETE BEAMS, ELEVATED SLABS & WALLS 4000psi EXTERIOR SLABS
3000psi FOR ALL OTHER CONCRETE
CONCRETE SHALL BE PLACED AND CURED ACCORDING TO ACI STANDARDS AND
SPECIFICATIONS.
SUBMIT PROPOSED MIX DESIGN WITH RECENT FIELD CYLINDER OR LAB TESTS FOR
REVIEW PRIOR TO USE. MIX SHALL BE UNIQUELY IDENTIFIED BY MIX NUMBER OR
OTHER POSITIVE IDENTIFICATION. MIX SHALL MEET THE REQUIREMENTS OF ASTM C33
FOR COARSE AGGREGATE. CONCRETE SHALL COMPLY WITH THE REQUIREMENTS OF
ASTM STANDARD C94 FOR MEASURING, MIXING, TRANSPORTING, ETC. CONCRETE
TICKETS SHALL BE TIME STAMPED WHEN CONCRETE IS BATCHED. THE MAXIMUM TIME
ALLOWED FROM THE TIME THE MIXING WATER IS ADDED UNTIL IT IS DEPOSITED IN ITS
FINAL POSITION SHALL NOT EXCEED ONE AND ONE HALF (1-1/2) HOURS. IF FOR ANY
REASON THERE IS A LONGER DELAY THAN THAT STATED ABOVE,THE CONCRETE
SHALL BE DISCARDED. IT SHALL BE THE RESPONSIBILITY OF THE TESTING LAB TO
NOTIFY THE OWNER'S REPRESENTATIVE AND THE CONTRACTOR OF ANY
NONCOMPLIANCE WITH THE ABOVE. SLABS SHALL BE CURED USING A DISSIPATING
CURING COMPOUND MEETING ASTM STANDARD C309 TYPE 1-D AND SHALL HAVE A
FUGITIVE DYE. THE COMPOUND SHALL BE PLACED AS SOON AS THE FINISHING IS
COMPLETED OR AS SOON AS THE WATER HAS LEFT THE UNFINISHED CONCRETE.
SCUFFED OR BROKEN AREAS IN THE CURING MEMBRANE SHALL BE RECOATED DAILY.
CALCIUM CHLORIDES SHALL NOT BE UTILIZED; OTHER ADMIXTURES MAY BE USED
ONLY WITH THE APPROVAL OF THE ENGINEER.
CONSTRUCTION OR CONTROL JOINTS SHALL BE PROVIDED IN SLABS ON GRADE SO
THAT THE MAXIMUM AREA OF THE SLAB BETWEEN JOINTS SHALL BE 144 SQUARE FEET,
OR AS SHOWN ON THE PLANS. SAW CUT CONTROL JOINTS SHALL BE MADE AS SOON
AS SLAB WILL SAFELY SUPPORT MEN AND EQUIPMENT AND THE SLAB WILL NOT BE
DAMAGED BY EQUIPMENT, BUT NO LATER THAN 24 HOURS. ASPECT RATIO (LONGSIDE
TO SHORTSIDE OF CONCRETE AREA) SHALL NOT EXCEED 1.5. NO EMBEDDED ANGLES
OR OTHER FIXED METAL ITEMS SHALL EXTEND THROUGH JOINTS, UNLESS OTHERWISE
NOTED. EMBEDDED ANGLES AND OTHER FIXED METAL ITEMS SHALL BE CONTINUOUS
BETWEEN CONCRETE JOINTS, UNLESS OTHERWISE NOTED. ENGINEER SHALL
APPROVE LOCATION OF ALL JOINTS NOT SHOWN ON DRAWINGS. CONTRACTOR SHALL
SUBMIT SHOP DRAWINGS FOR APPROVAL.
CONCRETE MIX DESIGNS SHALL INCLUDE A WRITTEN DESCRIPTION INDICATING WHERE
EACH PARTICULAR MIX IS TO BE PLACED WITHIN THE STRUCTURE. IF ACCEPTED, PEA
ROCK PUMP MIX USE IS LIMITED TO VERTICAL ELEMENT POURS AND BEAM POURS
LESS THAN 60 LINEAL FEET PER POUR.
CONCRETE DESIGN MIX SUBMITTALS SHALL INCLUDE TESTED, STATISTICAL BACK-UP
DATA AS PER CHAPTER 5 OF ACI 318.
WATER/CEMENT RATIO FOR CONCRETE AT EXTERIOR BALCONIES OR CONCRETE
EXPOSED TO WEATHER SHALL NOT EXCEED 0.40 BY WEIGHT.
CONCRETE TESTING:
AN INDEPENDENT TESTING LABORATORY SHALL PERFORM THE FOLLOWING TESTS ON
CAST IN PLACE CONCRETE:
A) ASTM C143 - "STANDARD TEST METHOD FOR SLUMP OF PORTLAND CEMENT
CONCRETE." SLUMP RANGE SHALL BE 3 TO 4 INCHES.
B) ASTM C39 - "STANDARD TEST METHOD FOR COMPRESSIVE STRENGTH OF
CYLINDRICAL CONCRETE SPECIMENS." A SEPARATE TEST SHALL BE CONDUCTED
FOR EACH CLASS, FOR EVERY 50 CUBIC YARDS (OR FRACTION THEREOF), PLACED
PER DAY. CYLINDER(S) QUANTITIES AND TEST AGE AS FOLLOWS:
1 AT 7 DAYS
2 AT 28 DAYS
ONE ADDITIONAL RESERVE CYLINDER TO BE TESTED UNDER THE DIRECTION OF THE
ENGINEER, IF REQUIRED. IF 28 DAY STRENGTH IS ACHIEVED, THE ADDITIONAL
CYLINDER(s) MAY BE DISCARDED.
WALL CONTROL JOINTS SHALL BE PROVIDED IN CONCRETE MASONRY
CONSTRUCTION AT LOCATIONS INDICATED ON THE STRUCTURAL DRAWINGS. IF
THEY ARE NOT SHOWN, LOCATE WALL CONTROL JOINTS AT 24'-0" o.c. MAXIMUM AND
SHOW LOCATIONS ON SHOP DRAWINGS. HORIZONTAL WALL REINFORCING SHALL
BE STOPPED EACH SIDE OF CONTROL JOINTS. BOND BEAM, TIE BEAM OR KNOCK-
OUT BLOCK BEAM REINFORCEMENT SHALL BE CONTINUOUS THROUGH CONTROL
JOINTS. SEE ARCHITECTURAL DRAWINGS FOR SEALANT REQUIREMENTS AT
CONTROL JOINTS.
SUBMIT PROPOSED GROUT MIX DESIGN FOR REVIEW PRIOR TO USE. MIX SHALL BE
UNIQUELY IDENTIFIED BY MIX NUMBER OR OTHER POSITIVE IDENTIFICATION. GROUT
SLUMP SHALL BE BETWEEN 8 AND 11 INCHES. USE OF SUPERPLASTICIZER IS
PROHIBITED.
CELLS TO BE GROUT FILLED SHALL HAVE VERTICAL ALIGNMENT SUFFICIENT TO
MAINTAIN A CLEAR, UNOBSTRUCTED, CONTINUOUS VERTICAL GROUT SPACE.
CLEANOUT OPENINGS SHALL BE PROVIDED AT THE BOTTOM OF CELLS TO BE GROUT
FILLED IN EACH POUR IN EXCESS OF 5 FEET IN HEIGHT. ANY OVERHANGING MORTAR
OR OTHER OBSTRUCTION OR DEBRIS SHALL BE REMOVED FROM THE INSIDES OF
SUCH CELL WALLS. THE CLEANOUTS SHALL BE SEALED BEFORE GROUTING, AFTER
INSPECTION. PLACE METAL LATH OR WIRE SCREEN OVER CORES NOT TO BE FILLED
(SHEET METAL AND FELT PROHIBITED).
VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION AT TOP AND BOTTOM AND
AT INTERVALS NOT EXCEEDING 192 BAR DIAMETERS. CELLS CONTAINING
REINFORCEMENT SHALL BE FILLED SOLIDLY WITH GROUT. GROUT SHALL BE
POURED IN LIFTS OF 4 FEET MAXIMUM HEIGHT. GROUT SHALL BE CONSOLIDATED AT
TIME OF PLACING BY VIBRATING AND RECONSOLIDATED LATER BY VIBRATING
BEFORE PLASTICITY IS LOST.
WHEN TOTAL GROUT POUR EXCEEDS 5 FEET IN HEIGHT, THE GROUT SHALL BE
PLACED IN 4 FOOT LIFTS. MINIMUM CELL DIMENSION SHALL BE IN ACCORDANCE
WITH TABLE 5 OF ACI 530.1 (3" X 3" FOR COARSE GROUT, 12 FT. MAXIMUM POUR
HEIGHT).
WHEN THE GROUTING IS STOPPED FOR ONE HOUR OR LONGER, HORIZONTAL
CONSTRUCTION JOINTS SHALL BE MADE BY STOPPING THE POUR OF GROUT NOT
LESS THAN 1-1/2 INCH BELOW THE TOP OF THE UPPERMOST UNIT GROUTED.
WALL CONSTRUCTION JOINTS SHALL BE SPACED @ 24'-0" O.C. MAX. WITH TYP. VERT.
REINF. AT EA. SIDE OF JOINT. HORIZONTAL JOINT REINF. SHALL TERMINATE 2" FROM
EA. SIDE OF JOINT. BOND BEAM/TIE BEAM REINF. SHALL BE CONTINUOUS THROUGH
WALL C.J.
INTERIOR CMU WALLS SHALL HAVE SMOOTH SURFACE. SEE ARCH'L.
FOR FINISHING REQUIRED. SEE ARCH'L SPECIFICATIONS FOR MASONRY VENEER
REQUIREMENTS.
LINTELS FOR MASONRY:
OPENINGS NOT PROVIDED WITH CONCRETE BEAMS SHALL BE SPANNED WITH
PRECAST CONCRETE LINTELS WITH A WIDTH TO MATCH WALL WIDTH AND WITH 2#5
REINF. BARS, MIN.. ALL PRECAST LINTELS SHALL BEAR A MINIMUM OF 8" AT EACH
END. PRECASTER TO DESIGN PRECAST LINTELS FOR LOADS NOTED ON THIS SHEET.
POST-INSTALLED ANCHORS:
POST-INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE
CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM
THE STRUCTURAL ENGINEER-OF-RECORD PRIOR TO INSTALLING POST-INSTALLED
ANCHORS IN PLACE OF MISSING OR MISPLACED CAST-IN-PLACE ANCHORS. CARE
SHALL BE TAKEN IN PLACING POST-INSTALLED ANCHORS TO AVOID CONFLICTS WITH
EXISTING REBAR. HOLES SHALL BE DRILLED AND CLEANED IN ACCORDANCE WITH
THE MANUFACTURER'S WRITTEN INSTRUCTIONS. SUBSTITUTION REQUESTS FOR
PRODUCTS OTHER THAN THOSE SPECIFIED BELOW, SHALL BE SUBMITTED BY THE
CONTRACTOR TO THE STRUCTURAL ENGINEER-OF-RECORD ALONG WITH
CALCULATIONS THAT ARE PREPARED & SEALED BY A REGISTERED PROFESSIONAL
ENGINEER IN FLORIDA. THE CALCULATIONS SHALL DEMONSTRATE THAT THE
SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING EQUIVALENT OR BETTER
PERFORMANCE VALUES OF THE SPECIFIED PRODUCT USING THE APPROPRIATE
DESIGN PROCEDURE AND/OR STANDARD(S) AS REQUIRED BY THE BUILDING CODE.
USE THE ANCHORS SPECIFIED ON THE PLANS & SECTIONS, U.N.O.
CONCRETE ANCHORS:
MECHANICAL ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE SHALL
HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ACI 355.2 AND
ICC-ES AC193. PRE-APPRIVED MECHANICAL ANCHORS INCLUDE:
1. SIMPSON STRONG-TIE 'STRONG-BOLT' (ICC-ES ESR-1771)
2. SIMPSON STRONG-TIE 'TITEN-HD' (ICC-ES ESR-2713)
ADHESIVE ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE SHALL BE
INSPECTED AS FOLLOWS. AT THE ONSET OF EACH APPLICATION, A
MANUFACTURER'S REPRESENTATIVE MUST BE PRESENT TO WITNESS AT LEAST FIVE
COMPLETE INSTALLATIONS. INSTALLERS MUST BE TRAINED BY THE MANUFACTURER
EACH CERTIFIED INSTALLER WILL BE ISSUED A CERTIFICATION CARD TO VERIFY
THEIR TRAINING AND SHALL BE REQUIRED TO CARRY THEIR CERTIFICATION CARD
ON THEIR PERSON. CERTIFIED INSTALLERS SHALL PROVIDED WRITTEN
DOCUMENTATION THAT ALL ANCHORS HAVE BEEN INSTALLED PER THE
MANUFACTURER'S INSTRUCTIONS. ANCHORS SHALL ALSO HAVE BEEN TESTED AND
QUALIFIED FOR USE IN ACCORDANCE WITH ICC-ES AC306. PRE-APPROVED
ADHESIVE ANCHORS INCLUDE:
1. SIMPSON STRONG-TIE 'SET-XP' (ICC-ES ESR-2508)
2. HILTI HIT-RE 500 SD (ICC-ES ESR-2322)
MASONRY ANCHORS:
ANCHORAGE TO SOLID-GROUTED CONCRETE MASONRY.
MECHANICAL AND CONCRETE SCREW ANCHORS FOR USE IN SOLID-GROUTED
CONCRETE MASONRY SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN
ACCORDANCE WITH ICC-ES AC01 OR AC106, RESPECTIVELY. PRE-APPROVED
MECHANICAL AND CONCRETE SCREW ANCHORS INCLUDE:
SIMPSON STRONG-TIE 'WEDGE-ALL; (ICC-ES ESR-1396)
SIMPSON STRONG-TIE 'TITEN-HD' (ICC-ES ESR-1056)
ADHESIVE ANCHORS FOR USE IN SOLID-GROUTED CONCRETE MASONRY SHALL
HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ICC-ES AC58.
PRE-APPROVED ADHESIVE ANCHORS INCLUDE:
SIMPSON STRONG-TIE 'SET' (ICC-ES ESR-1772)
SIMPSON STRONG-TIE 'ACRYLIC-TIE' (ICC-ES ESR-1056)
HILTI HIT HY-70 (ICC-ES ER-5193)
ANCHORAGE TO HOLLOW CONCRETE MASONRY/UNREINFORCED CLAY BRICK
MASONRY
SCREW ANCHORS FOR USE IN HOLLOW CONCRETE MASONRY SHALL HAVE BEEN
TESTED AND QUALIFIED IN ACCORDANCE WITH ICC-ES AC106. PRE-APPROVED
SCREW ANCHORS INCLUDE:
SIMPSON STRONG-TIE 'TITEN-HD' (ICC-ES ESR-1056)
ADHESIVE ANCHORS WITH SCREEN TUBES FOR USE IN HOLLOW CONCRETE
MASONRY/UNREINFORCED CLAY BRICK MASONRY SHALL BE TESTED AND QUALIFIED
IN ACCORDANCE WITH ICC-ES AC58 OR AC60, AS APPROPRIATE. THE APPROPRIATE
SCREEN TUBE SHALL BE USED AS RECOMMENDED BY THE ADHESIVE
MANUFACTURER. PRE-APPROVED ADHESIVE ANCHORS WITH SCREEN TUBES
INCLUDE:
SIMPSON STRONG-TIE 'SET' (ICC-ES ESR-1772)
SIMPSON STRONG-TIE 'ACRYLIC-TIE' (ICC-ES ER-5791)
SIMPSON STRONG-TIE 'E' (ICC-ES ER-4945)
POWER-ACTUATED FASTENERS (PAF) SHALL BE BY SIMPSON STRONG-TIE (ICC-ES
ESR-2138) OR ENGINEER-APPROVED EQUAL.
GAS-ACTUATED FASTENERS (GAF) SHALL BE BY SIMPSON STRONG-TIE (ICC-ES
ESR-2811) OR ENGINEER-APPROVED EQUAL.
CONCRETE COVER FOR REINFORCING
CONCRETE CAST AGAINST AND
PERMANENTLY EXPOSED TO EARTH
CONCRETE EXPOSED TO EARTH OR WEATHER
#6 THRU #18 BARS
#5 BAR, W31 OR D31 WIRE, AND SMALLER
CONCRETE NOT EXPOSED TO EARTH OR WEATHER:
SLABS AND WALLS:
#11 AND SMALLER
BEAMS, COLUMNS:
PRIMARY REINF, TIES, STIRRUPS
3"
2" 1 1/2"
3/4"
1 1/2"
STRUCTURAL NOTES:
ELECTRONIC VERSIONS OF STRUCTURAL DRAWINGS ARE THE SOLE, COPYRIGHTED
PROPERTY OF BENNETT & PLESS, INC. ELECTRONIC VERSIONS OF DRAWINGS ARE
NOT TO BE USED OR TRANSFERRED WITHOUT THE EXPRESS, WRITTEN PERMISSION
OF BENNETT & PLESS, INC. ENGINEER, ENGINEER OF RECORD, AND DELEGATED
ENGINEER SHALL BE LICENSED AS A PROFESSIONAL ENGINEER IN THE STATE OF
FLORIDA.
GENERAL NOTES:
STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB
SPECIFICATIONS AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND
SITE DRAWINGS. CONSULT THESE DRAWINGS FOR DEPRESSIONS, AND OTHER
DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS.
DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. ANY
DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE
PROCEEDING WITH THE AFFECTED PART OF THE WORK.
THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE
BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE
ERECTION PROCEDURES AND SEQUENCE TO INSURE SAFETY OF THE BUILDING AND
ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE ADDITION OF NECESSARY
SHORING, SHEETING, TEMPORARY BRACING, GUYS OR TIEDOWNS.
DESIGN LOADS:
THE STRUCTURAL SYSTEM FOR THIS BUILDING HAS BEEN DESIGNED IN
ACCORDANCE WITH THE FLORIDA BUILDING CODE, 2023 EDITION. THE FOLLOWING
SUPERIMPOSED LOADINGS HAVE BEEN UTILIZED:
ROOF:
LIVE LOAD - 20 psf. (TOP CHORD)
-20 psf. (BOTTOM CHORD NON-CONCURRENT) DEAD LOAD - 15 psf. (BOTTOM CHORD)
-2.5 psf. (TOP AND BOTTOM CHORDS AVAILABLE TO
RESIST UPLIFT)
FLOOR:
LIVE LOAD - 125 psf DEAD LOAD - X psf SELFWEIGTH (CONECRETE FLOOR)
-25 psf
WIND:
Vult=160 MPH, Vasd=116 MPH EXPOSURE C, RISK CATEGORY II, INT.
PRESS. COEFF. ±0.18 THIS STRUCTURE IS DESIGNED AS AN
ENCLOSED STRUCTURE.
SNOW & SEISMIC (FLORIDA):
IN ACCORDANCE WITH CHAPTER 1 SECTION 101.2 OF THE 2023
FLORIDA BUILDING CODE, SEISMIC AND SNOW LOADS WERE NOT
UTILIZED FOR THIS PROJECT:
"CODE REQUIREMENTS THAT ADDRESS SNOW LOADS AND
EARTHQUAKE LOADS ARE PERVASIVE; THEY ARE LEFT IN PLACE
BUT SHALL NOT BE UTILIZED OR ENFORCED BECAUSE FLORIDA HAS
NO SNOW LOAD OR EARTHQUAKE THREAT."
SHOP DRAWINGS AND CALCULATIONS:
SHALL BE PREPARED FOR ALL WORK AND SUBMITTED FOR REVIEW. SHOP
DRAWINGS SHALL BEAR THE SIGNATURE AND IMPRESSED SEAL OF A FLORIDA
REGISTERED PROFESSIONAL ENGINEER.
SHOP DRAWING REVIEW:
SHOP DRAWINGS WILL BE PROVIDED FOR ALL WORK AND WILL BE REVIEWED FOR
GENERAL COMPLIANCE WITH THE DESIGN INTENT OF THE CONTRACT DOCUMENTS
ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH,
ELEVATIONS, DIMENSIONS, ETC. SHOP DRAWINGS SHALL BE REVIEWED BY THE
CONTRACTOR AND OWNER'S REP PRIOR TO SUBMITTAL TO THE
ARCHITECT/ENGINEER. DRAWINGS SUBMITTED WITHOUT REVIEW WILL BE
RETURNED UNCHECKED. SHOP DRAWING SUBMITTALS, IF NOT SUBMITTED
ELECTRONICALLY, SHALL INCLUDE THREE SETS OF PRINTS. ONE SET OF PRINTS
WILL BE RETAINED BY THE ENGINEER, ONE BY THE ARCHITECT, ONE BY THE LOCAL
BUILDING DEPARTMENT (WHERE REQUIRED) AND THE CONTRACTOR SHALL MAKE
PRINTS AS REQUIRED FOR DISTRIBUTION. IN ALL INSTANCES THE CONTRACT
DOCUMENTS WILL GOVERN OVER THE SHOP DRAWINGS UNLESS OTHERWISE
SPECIFIED IN WRITING BY THE ENGINEER.
SHOP DRAWINGS FOR ALL STRUCTURAL ELEMENTS SHALL BE SUBMITTED TO B&P
WITH 10 BUSINESS DAYS AS A MINIMUM TIME TO BE REVIEWED (MAXIMUM SHEET OR
PAGE COUNT OF 30). IN THE CASE OF A LARGE SUBMITTAL, OR MORE THAN 1
SUBMITTAL FOR THE SAME PROJECT, AN ADDITIONAL BUSINESS DAY SHALL BE
REQUIRED FOR EVERY 5 PAGES/SHEETS OVER 30. THE TIME INDICATED ABOVE IS
FOR B&P'S REVIEW ONLY; IN ORDER TO MEET PROJECT SCHEDULES, THE
CONTRACTOR MUST INCLUDE ENOUGH TIME FOR DELIVERY, ARCHITECTURAL
REVIEW, AND OWNER'S REVIEW.
THERE SHALL BE NO DEVIATION FROM THESE STRUCTURAL CONSTRUCTION
DOCUMENTS. IF THE CONTRACTOR OR PROVIDER OF THE SHOP DRAWINGS
PROPOSE ANY CHANGES, THOSE CHANGES SHALL BE CLEARLY INDICATED, AND
SIGNED AND SEALED DRAWINGS AND CALCULATIONS BY A REGISTERED FLORIDA
PROFESSIONAL ENGINEER SUBMITTED. ANY CHANGES NOT APPROVED OR
SUBMITTED WITHOUT THE PROPER DOCUMENTATION INDICATED PREVIOUSLY, WILL
RESULT IN REVISIONS BY THE ENGINEER OR ARCHITECT-OF-RECORD. THE COST
FOR SAID REVISIONS, INCLUDING ENGINEERING AND ARCHITECTURAL FEES SHALL
BE BORNE BY THE CONTRACTOR.
SHOP DRAWINGS FOR SPECIALTY ENGINEERED PRODUCTS:
ALL SPECIALTY ENGINEERED PRODUCTS OR SYSTEMS REQUIRE SIGNED & SEALED
CALCULATIONS AND FABRICATION AND ERECTION DRAWINGS PREPARED BY A
DELEGATED ENGINEER.
THIS INCLUDES BUT IS NOT LIMITED TO CANOPIES, PRE-ENGINEERED TRUSSES, ICF
WALL SYSTEMS, ALL LIGHT GAUGE METAL STUD FRAMING SYSTEMS, ALUMINUM
WALL SYSTEMS, GLAZED CURTAIN WALLS, PREFABRICATED STEEL STAIRS &
RAILINGS, ARCHITECTURAL PRECAST CONCRETE ELEMENTS, STRUCTURAL PRECAST
OR TILT-UP SYSTEMS, GLASS FIBER REINFORCED CONCRETE PANEL SYSTEMS, OPEN
WEB STEEL JOISTS, STRUCTURAL STEEL CONNECTIONS REQUIRING ENGINEERING,
TILT-WALL ERECTION DRAWINGS, GLULAM BEAMS, TECTUM PLANKS, PEMB, ETC.
SUBMITTALS SHALL CLEARLY IDENTIFY THE SPECIFIC PROJECT AND APPLICABLE
CODES, LIST THE DESIGN CRITERIA, AND SHOW ALL DETAILS AND PLANS NECESSARY
FOR PROPER FABRICATION AND INSTALLATION. CALCULATIONS AND SHOP
DRAWINGS SHALL IDENTIFY SPECIFIC PRODUCT UTILIZED. GENERIC PRODUCTS WILL
NOT BE ACCEPTED.
SHOP DRAWINGS AND CALCULATIONS SHALL BE PREPARED UNDER THE DIRECT
SUPERVISION AND CONTROL OF THE DELEGATED ENGINEER. SHOP DRAWINGS AND
CALCULATIONS REQUIRE THE IMPRESSED SEAL, DATE AND SIGNATURE OF THE
DELEGATED ENGINEER.
COMPUTER PRINTOUTS ARE AN ACCEPTABLE SUBSTITUTE FOR MANUAL
COMPUTATIONS PROVIDED THEY ARE ACCOMPANIED BY SUFFICIENT DESCRIPTIVE
INFORMATION TO PERMIT THEIR PROPER EVALUATION. SUCH DESCRIPTIVE
INFORMATION SHALL BEAR THE IMPRESSED SEAL AND SIGNATURE OF THE
DELEGATED ENGINEER AS AN INDICATION THAT HE/SHE HAS ACCEPTED
RESPONSIBILITY FOR THE RESULTS. SEPIAS DO NOT REQUIRE SIGNATURE AND
SEAL. THE STRUCTURAL ENGINEER WILL RETAIN ONE SIGNED AND SEALED
BLUELINE PRINT FOR RECORD.
DRAWINGS PREPARED SOLELY TO SERVE AS A GUIDE FOR FABRICATION AND
INSTALLATION (SUCH AS REINFORCING STEEL SHOP DRAWINGS OR STRUCTURAL
STEEL ERECTION DRAWINGS) AND REQUIRING NO ENGINEERING DO NOT REQUIRE
THE SEAL OF A DELEGATED ENGINEER.
CATALOG INFORMATION ON STANDARD PRODUCTS DOES NOT REQUIRE THE SEAL
OF A DELEGATED ENGINEER.
REVIEW BY THE STRUCTURAL ENGINEER OF RECORD OF SUBMITTALS IS LIMITED TO
VERIFYING THE FOLLOWING:
a) THAT THE SPECIFIED STRUCTURAL SUBMITTALS HAVE BEEN
FURNISHED.
b) THAT THE STRUCTURAL SUBMITTALS HAVE BEEN SIGNED
AND SEALED BY THE DELEGATED ENGINEER.
c) THAT THE DELEGATED ENGINEER HAS UNDERSTOOD THE
DESIGN INTENT AND HAS USED THE SPECIFIED STRUCTURAL
CRITERIA. (NO DETAILED CHECK OF CALCULATIONS WILL
BE MADE).
WOOD:
WOOD: THE WOOD COMPONENTS SHALL BE IN ACCORDANCE WITH CHAPTER 23,
WOOD, OF THE FBC 2023. AND STRUCTURAL WOOD COMPONENTS (BEAMS, JOISTS,
RAFTERS, POSTS, ETC.) SHALL BE NO. 2 SOUTHERN PINE CONFORMING TO THE
LATEST EDITION OF NDS.
ALL WOOD TO WOOD CONNECTIONS SHALL EMPLOY METAL ANCHORS. NO TOE OR
END NAILING SHALL BE PERMITTED, EXCEPT FOR TOP AND BOTTOM PLATES IN
WALLS. (U.N.O. ON DRAWINGS.)
STUDS OR JOISTS SHALL NOT BE CUT TO INSTALL PLUMBING OR WIRING UNLESS
METAL OR WOOD SIDE PIECES ARE PROVIDED TO STRENGTHEN THE MEMBER.
NAIL MULTIPLE PLY BEAMS WITH TWO ROWS 16d NAILS AT 12" O.C. TOP AND
BOTTOM. BOLT 3 AND 4 PLY MICROLAMS WITH 2 ROWS 1/2"∅ THRU-BOLTS AT 24" O.C.
(STAGGERED AT 12" O.C.) SPLICES ARE NOT PERMITTED IN ANY PLY BETWEEN
SUPPORTS.
TIMBER FASTENING SHALL BE PER THE 2023 FBC. "FASTENING SCHEDULE" UNLESS
NOTED AS GREATER ON DRAWINGS. ALL WOOD BEAMS TO BEAR ON MULTIPLE
STUDS, SAME NUMBER OF STUDS AS NUMBER OF BEAM, PILES (2) MINIMUM, UNLESS
GREATER NUMBER NOTED ON PLANS. PROVIDE ADDITIONAL FULL HEIGHT STUDS
DOWN TO FOUNDATION, WITH SOLID BLOCKING AT FLOORS.
MULTIPLE STUD POSTS WITH (2) OR MORE STUDS SHALL BE NAILED TOGETHER
WITH EACH STUD NAILED TO THE ADJACENT STUD W/(2) ROWS 16d NAILS AT 12"o.c.
STAGGERED AT 6"o.c.
ALL WALL DOUBLE TOP PLATES, SHALL BE LAPPED AT CORNERS AND
INTERSECTIONS AND FASTENED PER 2023 FBC FASTENING SCHEDULE. ALL DOUBLE
PLATE END JOINTS SHALL BE OFFSET AT LEAST 24". DOUBLE PLATES TO BE
FASTENED TOGETHER PER FASTENING SCHEDULE. PROVIDE SIMILAR CONNECTIONS
AT TRIPLE PLATES.
ALL NAILS SHALL BE COMMON NAILS U.N.O. ON DRAWINGS.
AT INTERIOR WALLS, PROVIDE (2) JACK STUDS AND (1) FULL HEIGHT STUDS EA. SIDE
OF OPENINGS U.N.O.
ALL BEAM-TO-BEAM FLUSH CONNECTIONS SHALL BE MADE USING BEAM HANGERS.
SPLICES ARE NOT PERMITTED IN RAFTERS, BEAMS OR POSTS EXCEPT AT
SUPPORTS.
ALL HEADERS FOR WOOD FRAMED WALLS ARE TO BE (2)2X10 #2 SOUTHERN PINE,
U.N.O.
WHERE DIRECT APPLIED CEILING DOES NOT OCCUR, PROVIDE 1x4 CONTINUOUS
BOTTOM FLANGE BRACING, WITH DIAGONAL KICKERS AT END SPACES, SPACED AS
DIRECTED BY THE MANUFACTURER.
NAILS NOTED IN SECTIONS, PLANS AND DETAILS ARE COMMON WIRE NAILS UNLESS
NOTED OTHERWISE. PNEUMATIC GUN NAILING IS ALLOWED WITH UNITS OF
EQUIVALENT GAGE AND LENGTH AS COMMON WIRE NAIL OF SIZE NOTED.
SPAN DIRECTION OF PLYWOOD SHEETS TO BE PERPENDICULAR TO FRAMING SPAN.
THE GYPSUM BOARD PLASTER COMPONENTS SHALL BE IN ACCORDANCE WITH
CHAPTER 25, GYPSUM BOARD AND PLASTER, OF THE FBC 2023.
STRUCTURAL WOOD COMPONENTS (BEAMS, JOISTS, RAFTERS, ETC.) SHALL HAVE
THE FOLLOWING MINIMUM ALLOWABLE FIBER STRESSES OF NO. 2 SOUTHERN PINE
CONFORMING TO THE LATEST EDITION OF NDS, AS FOLLOWS:
SHEAR Fv = 175 psi.
BENDING 2X6 Fb = 1,000 psi.
BENDING 2X8 Fb = 925 psi.
BENDING 2X10 Fb = 800 psi.
BENDING 2X12 Fb = 750 psi.
MICROLAM OR PARALLAM TO HAVE Fb= 2,600 psi. MIN, E=1,900 ksi MIN.
WOOD IN CONTACT WITH CONCRETE OR MASONRY, EXPOSED TO EXTERIOR, AND AT
OTHER LOCATIONS AS SHOWN ON STRUCTURAL DRAWINGS, SHALL BE PROTECTED
OR PRESSURE TREATED IN ACCORDANCE WITH AMERICAN WOOD - PRESERVERS'
ASSOCIATION STANDARDS. MEMBER SIZES SHOWN ARE NOMINAL UNLESS NOTED
OTHERWISE.
ENGINEERED WOOD TRUSS SYSTEMS SHALL BE DESIGNED BY SUPPLIER'S
SPECIALTY ENGINEER (TRUSS SYSTEM ENGINEER) TO CONFIGURATION AND LOAD
CARRYING CAPACITY SHOWN ON DRAWINGS AND SPECIFICATIONS. ALTERNATE
TRUSS LAYOUTS ARE ACCEPTABLE ONLY AS A CHANGE ORDER WHICH WILL
INCLUDE ENGINEERING CHARGES FOR REDESIGN OF THE STRUCTURE BY THE
ENGINEER OF RECORD. SUBMIT SHOP DRAWINGS FOR REVIEW PRIOR TO
FABRICATION. SHOP DRAWINGS SHALL SHOW AND SPECIFY CONNECTOR TYPES
UTILIZED WITHIN TRUSSES, AS WELL AS CONNECTORS UTILIZED IN OTHER
CONNECTIONS AND ATTACHMENTS BETWEEN TRUSSES OR COMPONENTS SUPPLIED
AS PART OF THE ENGINEERED TRUSS SYSTEM. AN ERECTION DRAWING SHALL BE
INCLUDED, IDENTIFYING TRUSS SYSTEM COMPONENTS, AS WELL AS PERMANENT
BRACING REQUIRED FOR TRUSS DESIGN. SUPPLIER SHALL NOT USE GYPSUM
BOARD AS A PERMANENT, TRUSS BRACING ELEMENT.
ENGINEERED SHOP DRAWINGS SHALL BEAR THE SIGNATURE AND IMPRESSED SEAL
OF A FLORIDA REGISTERED PROFESSIONAL ENGINEER AS THE SPECIALTY
ENGINEER. THE FOLLOWING LOAD DURATION FACTORS SHALL BE USED:
DEAD LOAD 0.90
DEAD LOAD + FLOOR LIVE LOAD 1.00
DEAD LOAD + ROOF LIVE LOAD 1.25
DEAD LOAD + WIND LOAD 1.6
PLYWOOD FLOOR, WALL AND ROOF SHEATHING ARE DESIGNED AS DIAPHRAGMS
AND SHALL COMPLY WITH APPLICABLE PROVISIONS OF CHAPTER 23 OF THE 2020
FLORIDA BUILDING CODE. UNLESS SHOWN OTHERWISE, SPAN RATED PANELS
SHALL BE FASTENED TO NOMINAL 2X SOUTHERN PINE FRAMING SPACED UP TO 24"
O/C. IN ACCORDANCE WITH THE FOLLOWING:
PANELS UP TO 5/8" THICK: 10d NAILS AT 6" O/C. EDGE, 12"
O/C. ELSEWHERE.
PANELS UP TO 3/4" THICK: 12d NAILS AT 6" O/C. EDGE, 12"
O/C. ELSEWHERE.
WOOD FRAMING CONNECTORS:
ALL CONNECTORS SHALL BE GALVANIZED [Z-MAX COATED] (AS AVAILABLE).
CONNECTOR MODEL NUMBERS SHOWN ARE Strong tie CONNECTORS AS MANUFACTURED BY SIMPSON Strong Tie Co., 1450 DOOLITTLE DR., P.O. BOX 1568, SAN
LEANDRO, CA 94577. SUBSTITUTIONS ARE ACCEPTABLE WITH THE APPROVAL OF
THE STRUCTURAL ENGINEER OF RECORD. UNLESS SHOWN OTHERWISE, INSTALL
SIZE AND NUMBER OF FASTENERS SHOWN IN LATEST SIMPSON CATALOG.
MASONRY WALLS:
MASONRY UNITS SHALL MEET ASTM C-90 FOR HOLLOW LOAD BEARING TYPE
MASONRY WITH UNIT STRENGTH OF 1900 psi ON THE NET AREA (f'm = 1900 psi).
MORTAR SHALL BE TYPE "M" OR "S" AND MEET ASTM C-270. GROUT SHALL BE 2000 psi
MINIMUM COMPRESSIVE STRENGTH AND MEET ASTM C-476. PROVIDE HOOKED
DOWELS IN FOOTINGS FOR VERTICAL REINFORCING ABOVE. LAP SPLICES 48 BAR
DIAMETERS.
BLOCK CELLS SHALL BE GROUT FILLED WITH VERTICAL REINFORCING BARS AT
CORNERS, INTERSECTIONS, EACH SIDE OF OPENINGS OVER 4 FEET WIDE, AND AS
SHOWN ON THE PLANS. DOWELS SHALL BE USED TO PROVIDE CONTINUITY INTO
THE STRUCTURE ABOVE AND/OR BELOW, UNLESS NOTED OTHERWISE. USE METAL
LATH, MORTAR, OR SPECIAL UNITS TO CONFINE CONCRETE AND GROUT TO AREA
REQUIRED. MASONRY SHALL BE LAID IN RUNNING BOND PATTERN UNLESS NOTED
OTHERWISE. INTERSECTING WALLS SHALL BE INTERLOCKED WITH RUNNING BOND
UNLESS NOTED OTHERWISE.
PROVIDE 9 GAGE GALVANIZED HORIZONTAL JOINT REINFORCING (DUR-O-WALL OR
ENGINEER APPROVED SUBSTITUTION) AT ALTERNATE BLOCK COURSES.
CX
FX.X
N O
TE
NOTE 2
NOTE 3
NOTE 3
NOTE 3
EXISTING STRUCTURE TO REMAIN
NOTE 3
NOTE 4
NOTE 4
NOTE 4 NOTE 4
NOTE 3
NOTE 4
H
SS
"x
4" x1
/4 " B
EA
M
EXISTING ROOF FRAMING TO REMAIN
W O
LM
AN
IZ
ED
.2
5x
.2
PS
L
H
SS
"x
4" x1
/4 " B
EA
M
WOLMANIZED 5.25x11.25 PSL
0" 1"
N
PROJECT MANAGER:
A/E OF RECORD:
PROJECT NO:
(C) COPYRIGHT 2021 SWEET SPARKMAN ARCHITECTS, INC.
SHEET TITLE:
SHEET No.:
SCALE:
DRAWN BY:
REV DESCRIPTION DATE
GRAPHIC SCALE:
N O
T
FO
R C
O N
ST
R
U
CT
IO
N
PR
O
JE
C
T
TI
TL
E:
IS
M
AI
N
ST
RE
ET
, S
UI
TE
SA
RA
SO
TA
, F
L 3
SW
EE
TS
PA
RK
MA
N.
CO
M T
1.9
.00
FL
A
R0
DRAWING SET:
C
LI
EN
T:
AD
D
R
ES
S:
1/4" = 1'-0"
22716
FOUNDATION & ROOF
FRAMING PLANS
SA111
D
ES
IG
N
D
EV
EL
O
PM
EN
T
SN
O
O K
H
AV
EN
P
AR
K
IM
PR
O
VE
M
EN
TS
SA
R
AS
O
TA
C
O U
N
TY
E . V
EN
IC
E
AV
EN
U
E, V
EN
IC
E, F
L
TCW
OUTFITTER BUILDING
PRELIMINARY
NOT FOR CONSTRUCTION
DO NOT SCALE OFF THESE DRAWINGS. LAYOUT THE
BUILDING USING APPLICABLE CONTRACT DRAWINGS,
BUILDING DIMENSIONS AND THE LOCATION OF ALL
STRUCTURAL ELEMENTS INCLUDING BUT NOT LIMITED TO
SLAB EDGES, WALLS, COLUMNS, OPENINGS AND
DEPRESSIONS SHALL BE COORDINATED WITH THE
ARCHITECTURAL DRAWINGS PRIOR TO LAYOUT OF THE
BUILDING. RESOLVE ANY DISCREPANCIES.
TO THE BEST OF THE ENGINEER-OF-RECORD'S
KNOWLEDGE AND ABILITY, THE COMPLETED STRUCTURE
DEPICTED ON THESE DOCUMENTS COMPLIES WITH THE
APPLICABLE MINIMUM BUILDING CODES.
NOTE:
© 2024 - bennett & pless, inc.
All rights reserved.
1381 Fifth Street Sarasota, Florida 34236 Telephone: (941) 955-4555 Fax: (941) 955-9333 www.bennett-pless.com C.O.A. #30502 bennett & pless, inc.
B&P JOB NUMBER 23.03.082
1. INDICATES DIRECTION OF WOOD COMPOSITE DECKING.
2. P.T. 2x4 WOOD SLEEPERS RIPPED TO FIT OVER EXISTING CONC. SLAB.
3. MASONRY INFILL PER DETAIL ON SA501.
4. EXIST. GROUT FILLED SOLID CELL W/ #5 BAR (F.V.). IF REBAR IS NOT PRESENT, REINF.
W/ #5 BAR PER DETAIL "WALL REINFORCEMENT OF EXISTING MASONRY" ON SA501.
5. VERIFY DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS BEFORE
COMMENCING CONSTRUCTION. DISCREPANCIES SHALL BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER. FOR ADDITIONAL
INFORMATION SEE ARCHITECTURAL DRAWINGS.
6. FOR DIMENSIONS NOT SHOWN, SEE OTHER STRUCTURAL DRAWINGS AND VERIFY WITH
ARCHITECTURAL DRAWINGS. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION
OF THE ARCHITECT AND THE…