Attachment C - Instructions for Collecting Primer Residue (updated 110526).pdf
PDF 324 KB Posted
- Attached to
- Gunshot Primer Residue Collection Kits
- Solicitation number
- QQ-131204
- Issued by
- Halifax County, Virginia
About this file
This document is a procedural instruction sheet issued by the Virginia Department of Forensic Science for the collection and submission of gunshot primer residue (PR) samples. The instructions provide detailed step-by-step guidance for collecting primer residue from both the right and left hands of subjects using specialized collection kits containing scanning electron microscopy (SEM) stubs. The collection procedure involves swabbing the web area and palm area of each hand with the adhesive-coated stub, sealing the samples in labeled vials, completing an accompanying information form, and submitting the sealed kit along with a Request for Laboratory Examination Form to the Department of Forensic Science at 8850 Times Dispatch Boulevard, Suite 100, Mechanicsville, Virginia 23116, either by hand delivery or registered mail.
Critical procedural constraints and conditions specified in the instructions include a four-hour optimal collection window after a shooting event, with samples collected from living subjects more than eight hours after the incident no longer subject to routine analysis; samples from deceased subjects do not have this time limitation and should be collected before body movement when possible. Additional restrictions prohibit sample collection from subjects who have already been fingerprinted or who have washed their hands since the shooting, and operators must avoid contaminating the collecting surface, use appropriate hand hygiene, exercise sufficient pressure when sampling to create a mild skin indentation, and avoid heavily soiled or bloody areas when feasible, with protective barrier gloves required if blood exposure is possible. Questions regarding kit usage may be directed to the Department of Forensic Science's Central Laboratory Trace Evidence Section at (804) 786-6800.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STEP 1 Thoroughly wash your hands with soap and water, then dry them with a clean paper or cloth towel. If soap, water, and a clean towel are not available, then use the pre-moistened towelette provided in the kit.
STEP 2 RIGHT HAND:
(A) Carefully remove the cap from the vial labeled RIGHT HAND.
(B) While holding the vial cap, press the collecting surface of the stub onto the web area of the subject’s right hand until the area shown in Figure 2 has been covered.
(C) Now press the collecting surface of the stub onto the palm area of the subject’s right hand until the area shown in Figure 3 has been covered.
(D) After sampling the subject’s right hand (both back and palm), return cap to the RIGHT HAND vial, then fill out all information requested on the vial label.
STEP 3 LEFT HAND:
For collection from the left hand, follow the same procedure described in Step 2, but using the vial labeled LEFT HAND. (See Figures 4 and 5.)
STEP 4 Fill out all information on the enclosed Primer Residue Analysis Information Form.
INSTRUCTIONS FOR COLLECTING PRIMER RESIDUE (PR)
(READ ENTIRE INSTRUCTION SHEET BEFORE USING KIT)
FINAL INSTRUCTIONS
(A) Fill out all information requested on the front of the kit envelope.
(B) Return completed PR Analysis Information Form and the two capped vials to the kit envelope.
(C) Moisten kit envelope flap, then seal envelope. Affix Police Evidence Seal where indicated, then initial seal.
(D) Hand deliver or send by Registered Mail the sealed PR kit along with a completed REQUEST FOR LABORATORY EXAMINATION FORM to:
Department of Forensic Science 8850 Times Dispatch Blvd, Suite 100 Mechanicsville, VA 23116
Note: If sent by Registered Mail, package sealed kit in an appropriate container to prevent damage in transit. (Do not forget to send REQUEST FOR LABORATORY EXAMINATION FORM along with the kit.)
GSR1VASEM: INS.8 7/26
Figure 2 (WEB AREA of RIGHT HAND)
Figure 4 (WEB AREA of LEFT HAND)
Figure 3 (PALM AREA of RIGHT HAND)
Figure 5 (PALM AREA of LEFT HAND)
Fig. 1
NOTE
VIAL CAP
METAL STUB
COLLECTING SURFACE
(A) In control test firings, it has been shown that the concentration of primer residue significantly declines on living subjects after approximately 4 hours. Primer residue samples will no longer routinely be analyzed if collected from living individuals in excess of 8 hours after the shooting event. This does not apply to deceased subjects.
(B) If the subject is deceased, collect PR samples prior to moving body, if possible.
(C) Heavily soiled or bloody areas should be avoided if possible. (If there is blood on the subject’s hands or clothing, the investigating officers should first put on latex or other approved barrier gloves to protect him/her from bloodborne pathogens.)
(D) When a cap is removed from the clear plastic vials containing the Scanning Electron Microscopy (SEM) stubs, the adhesive collecting surface is exposed and care must be used to not drop the stub or contaminate the collection surface by allowing the surface to come in contact with an object other than the area that is to be sampled (See Figure 1).
(E) When pressing the collecting surface of SEM stubs (See Figure 1) on the subject’s skin, use enough pressure to cause a mild indention on the surface of the subject’s skin.
(F) Do not collect PR samples if the subject has already been fingerprinted.
(G) Do not collect PR samples if it is known the subject has washed his/her hands since the time of the shooting.
(H) Do not use this kit to submit expended casings to the laboratory.
(I) Allow kit to reach room temperature before using.
(J) If you should have any questions concerning the use of this kit, do not hesitate to call the Central Laboratory Trace Evidence Section of the Department of Forensic Science at (804) 786-6800.
File details come from the government source that posted it. Updated .